Fosroc Renderoc Laxtra Plus: Constructive Solutions
Fosroc Renderoc Laxtra Plus: Constructive Solutions
Uses Properties
Renderoc LAXtra Plus is suitable for mass infill to structural The following typical results were obtained at a water:powder
repairs in all types of loadbearing situation. Typical ratio of 0.135
applications would include, but not be limited to,
Test method Typical result
the following :
Drying shrinkage to ASTM C157-93
Repairs to columns suffering from major loss of section 7 days :< 300 microstrain
Soffit repairs where heavy loadbearing is required 28 days :< 500 microstrain
Flexural strength :> 9 N/mm2 at 28 days
Repairs to restricted access areas, where use of hand (BS 6319 Pt.3)
applied mortars would prove impractical Compressive strength :> 45 N/mm2 at 3 days
Repairs requiring high fluidity e.g. heavily congested steel (BS 1881 Pt.1161) > 56 N/mm2 at 7 days
or repairs into re-entrant angles/concealed voids > 70 N/mm2 at 28 days
Water absorption :< 2%
Any repairs requiring significant levels of loadbearing (BS 1881 Pt. 122)
Renderoc LAXtra Plus should be mixed and applied in strict Renderoc LAXtra Plus repair microconcrete system complies
accordance with the Product Method Statement, a copy of with the following international standards :
which may be obtained from your nearest Fosroc office.
ASTM C157-93 : Test for drying shrinkage
BS 1881 Pt. 122 : Water absorption
Estimating
Supply Precautions
Limitations During use, avoid inhalation of the dust and contact with the skin or
eyes. Wear suitable protective clothing - eye protection, gloves and
- Renderoc LAXtra Plus should not be used when the
respiratory equipment (particularly in confined spaces).
ambient temperature is below 5°C and falling.
The use of barrier creams to provide additional skin protection is
- Renderoc LAXtra Plus should not be part mixed, nor part
also advised. In case of contact with the skin, rinse with plenty of
bags used.
clean water, then cleanse thoroughly with soap and water.
- Renderoc LAXtra Plus should not be exposed to running
In case of contact with eyes, rinse immediately with plenty of clean
water either during application or prior to final set.
water and seek medical advice. If swallowed seek medical attention
- Water ponding is not recommended for curing. immediately - do not induce vomiting.
Fire
Storage
Renderoc LAXtra Plus, is non-flammable and thus presents
Shelf life
no fire hazard.
Renderoc LAXtra Plus has a shelf life of 12 months if kept in
For further information, please refer to the Product Material
a dry environment, in its original packing. If stored in conditions
Safety Data Sheet for Renderoc LAXtra Plus.
of high temperature and/or humidity, the shelf life may be
reduced to as little as 4 months.
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for
the Supply of Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to
obtain the latest version.
Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: [email protected]
Al Gurg Fosroc LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: [email protected]
United Arab Emirates Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: [email protected]
Kuwait, Boodai telephone: 4817618 fax: 4832124 email: [email protected]
www.fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: [email protected]
Qatar, Tadmur telephone: 4432365 fax: 4419517 email: [email protected]
UAE/0607/12/B