Beruflich Dokumente
Kultur Dokumente
S 5 0 3 7 - 0 - D LAS: Bylaser BCL 16T (RPP)
S 5 0 3 7 - 0 - D LAS: Bylaser BCL 16T (RPP)
S5037-0-D LAS
BYLASER BCL 16T (RPP)
REPLACES DIAGRAM:
S5037-0-C
TECHNICAL DATA
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
CONFIGURATION
TEST CONFIGURATION
-F1 -K1M
/8.2 /11.2
-F2
/6.4
-F3
/6.5
-F4
/6.6
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
DEFINITIONS
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
L1/8.1
-XP4A L1
L2/8.1
-XP4A L2
L3/8.1
-XP4A L3
1 3 5 13 21 1 3 5 13 21 1 3 5 13 21 1 3 5 13 21
-F2 -F3 -F4
-Q1 32A 25A 25A
14 22 2 4 6 14 22 2 4 6 14 22 2 4 6 14 22
1.6A-2.5A
/10.1
/10.2
/10.2
/10.3
(2A)
2 4 6
140M-RC2E-B25
140-RC-AFA11
(8)
+RES
(16) (10) (12) (12)
-XP4A PE PE
PE
PE
PE
/11.2 2 4 6 /11.3 2 4 6 /11.3 2 4 6 /11.4 2 4 6
+VML
+RES
TIME-DELAY 80A
VACUUM PUMP
3*400V/50Hz
3*400V/60Hz
3*480V/60Hz
EXCITATION
EXCITATION
TURBO FAN
MODULE 1
MODULE 2
SUPPLY
SUPPLY
SUPPLY
SUPPLY
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
+RES
10
11
14
13
16
1
7
-XS4A
OR OR OR OR OR OR OR OR
21 22
-K1 -K4M
.2 /11.4
22 21
A1 -K3 -K3M
-K1 /11.1 /11.3
21 22
A2
100-CR12DJ01
100-CRFA11 61 62
/8.3 1 2 -K2
/9.3 -K2M
/8.3 3 4
62 61
/11.3
/8.3 5 6
.3 21 22
22
/10.4 53 54
61 62 -K1M
/11.2
21
CONTACTOR MONITORING
EMERGENCY STOP
EMERGENCY STOP
EMERGENCY STOP
NO DANGEROUS
SUBSYSTEM
NO
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
L1/6.8
L2/6.8
L3/6.8 1 3
1 3 11
-F6 -F5
13A 10A
2 4 12 14 2 4
/10.4
1 3 5
-F1
2A
2 4 6
1 3 5
-K1 24V0.5/13.1
/7.2 2 4 6 4S
-X 24V0.1/10.1
5S
0V0.1/10.1
L1 L2 L3
-G1
NETZTEIL
+ -X
380-520VAC 0V0.5/13.1
PE - 2S
-X 24V1.1/9.1
24VDC 20A
24V1.3/11.1
3S
0V1.1/9.1
-X PE
-X PE
PE/12.4
PE
+RES +RES
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
SHUTTER NODE
GASMIX UNIT
CONTROLLER
EXCITATION
TURBINE
OUTPUT
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
gepr. Switzerland FAN / POWER SUPPLY UNIT Auftrag: S5037-0-D Bl: 8 von 15
31.05.12 scep
24V1.1/8.8
-X2A 4 PE -X2A 5
+RES +RES
-X2A 3 -X2A 6
-X2A 2 PE
+RES
13 13
-K2 -K3
.3 14 /11.1 14
-X2A 1
.3 13 14
/12.3 23 24
/12.2 33 34
/10.5 43 44
53 54
/7.3 61 62
HIGH VOLTAGE
PROTECTION
PROTECTION
RESONATOR
RADIATION
TUBE
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
gepr. Switzerland SHUTTER OK / HIGH VOLTAGE PROTECTION Auftrag: S5037-0-D Bl: 9 von 15
31.05.12 scep
24V0.1/8.8
20
-X2A 7 9 -X2A
+RES
13 13 13 13 11 53 43 43 14
21
-X2A 8 -X2A 10A -X2A
-X2A 10A
+RES
-X2A 11A
-X2A 11A
+RES
X11:11
X11:12
X11:13
X11:14
X12:2
X11:1
X11:2
X11:3
X11:4
X11:6
X11:8
X11:9
X2:5
-U5
IN0 IN1 IN2 IN3 IN5 IN7 IN8 IN10 IN11 IN12 IN13 IN17
/11.1
E5044
X2:4
X1:1
0V0.1/8.8
THERMAL TRIP 24V EXCITATION
COVERING BOTTOM
EXCITATION 1
EXCITATION 2
THERMAL TRIP
THERMAL TRIP
THERMAL TRIP
THERMAL TRIP
DEHUMIDIFIER
VACUUM PUMP
SAFETY GATE
MONITORING
PROTECTION
HV*SAFETY
RADIATION
TURBO FAN
CLOSED
CLOSED
RESET
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
X2:3
-U5
/10.1 E5044
GND1
24V1
/15.2 OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT11
X12:16
X12:10
X2:1
X12:5
X12:6
X12:7
X12:8
X12:9
X2:2
X3:1
X3:2
X3:3
0V1.3/8.8
+RES
EXCITATION 2
HOUR COUNTER
VACUUM PUMP
TURBO FAN
TURBO FAN
RESET
FAN
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
+RES
PE
3
9
-XS4A
OR OR OR OR OR OR GE-GN
33 23
-K2 -K2
/9.3 34 /9.3 24 PE/8.8
A1
14
15
16
17
18
19
A2
-X2A
700-HLT22Z24
14
/10.6 11
12
24
21
22
SAFETY GATE
EXCITATION
MODULE
CLOSED
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
+CNC
+RES
-X1 -X3
EN
EN
W11 W13
-D1X1
-D1X2
-D1 -D1.1 -D1.2 -D1.3
X1 X2
IN OUT
EL9011
UP 24V
6
24V0.5/8.8 UP 24V OUT4 /14.3 IN4 /14.7
0V/14.1
ETHERNET
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
ENABLE PIERCING 2
ENABLE PIERCING 3
ENABLE PIERCING 5
ENABLE PIERCING 4
ENABLE PIERCING 6
LPMOK
-D1.1 -D1.2
/13.3 /13.3
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT8 IN1 IN2 IN3 IN4
1 5 2 6 3 7 8 1 5 2 6
0V/13.5
+RES
-U20X3
REMOTED PULSED PIERCING
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
+RES
-X2 -U20X2
DATA
W12
CAN
CAN
MD/SSI
/11.1
E5044
Datum Name
Laser AG
=
gez. 31.05.12 scep 3362 Niederönz
BYLASER BCL 16T (RPP) + LAS
=============================================================================================================================
|BMK |ORT |Pfad |Material-Nr. |Bezeichnung |Typ |Hersteller |
=============================================================================================================================
|-D1 |+LAS |13.2 |10026883 |BUSKOPPLER |EK1100 |BECKHOFF |
-----------------------------------------------------------------------------------------------------------------------------
|-D1.1 |+LAS |13.3 |10026886 |OUTPUTMODUL |EL2008 |BECKOFF |
-----------------------------------------------------------------------------------------------------------------------------
|-D1.2 |+LAS |13.3 |10026884 |INPUTMODUL |EL1008 |BECKHOFF |
-----------------------------------------------------------------------------------------------------------------------------
|-D1.3 |+LAS |13.4 |10026882 |BUSENDKLEMME |EL9011 |BECKHOFF |
-----------------------------------------------------------------------------------------------------------------------------
|-F1 |+LAS |8.2 |10038252 |LEITUNGSSCHUTZSCHALTER |1489 2A/3P |ROCKWELL |
-----------------------------------------------------------------------------------------------------------------------------
|-F2 |+LAS |6.4 |10045288 |LEITUNGSSCHUTZSCHALTER |1489 32A/3P |ROCKWELL |
-----------------------------------------------------------------------------------------------------------------------------
|-F2 |+LAS |6.4 |10046768 |HILFSKONTAKT |1489-ABH12 (1O / 1S) |ROCKWELL |
-----------------------------------------------------------------------------------------------------------------------------
|-F3 |+LAS |6.5 |10038248 |LEITUNGSSCHUTZSCHALTER |1489 25A/3P |ROCKWELL |
-----------------------------------------------------------------------------------------------------------------------------
=============================================================================================================================
| Kabel.Nr.| Typ | Art | belegt | Kommt von | Geht nach |
=============================================================================================================================
| W11 | EN BL | 1 * KABEL | 1 | +LAS-D1X1 | +RES-X1 |
-----------------------------------------------------------------------------------------------------------------------------
| W12 | D-SUB 9P | 1 * KABEL | 1 | +LAS-U5X4B | +RES-X2 |
-----------------------------------------------------------------------------------------------------------------------------
| W13 | EN BL | 1 * KABEL | 1 | +LAS-D1X2 | +RES-X3 |
-----------------------------------------------------------------------------------------------------------------------------
| W85 | 4-12964 | 5 * KABEL | 4 | +RES-U6! | +RES-S20 |
-----------------------------------------------------------------------------------------------------------------------------
Ende der Liste