Justin Lo

Justin Lo

Greater Houston
4K followers 500+ connections

Activity

Join now to see all activity

Experience

  • Chevron Graphic

    Chevron

    Houston, Texas, United States

  • -

    Austin, Texas, United States

  • -

    Houston, Texas, United States

  • -

    Houston, Texas Area

  • -

    Houston, TX

  • -

    Houston, TX

  • -

    Durham, NC

  • -

    Durham, NC

Education

  • Duke University Graphic

    Duke University

    Activities and Societies: OSA, SPIE, Sigma Xi

    Google Scholar Profile:
    https://scholar.google.com/citations?user=1CXaVSAAAAAJ&hl=en

Publications

  • Assessment of the sensitivity and specificity of tissue-specific-based and anatomical-based optical biomarkers for rapid detection of human head and neck squamous cell carcinoma

    Oral Oncology

    We propose the use of morphological optical biomarkers for rapid detection of human head and neck squamous cell carcinoma (HNSCC) by leveraging the underlying tissue characteristics in aerodigestive tracts.

    Diffuse reflectance spectra were obtained from malignant and contra-lateral normal tissues of 57 patients undergoing panendoscopy and biopsy. Oxygen saturation, total hemoglobin concentration,and the reduced scattering coefficient were extracted. Differences in malignant and normal…

    We propose the use of morphological optical biomarkers for rapid detection of human head and neck squamous cell carcinoma (HNSCC) by leveraging the underlying tissue characteristics in aerodigestive tracts.

    Diffuse reflectance spectra were obtained from malignant and contra-lateral normal tissues of 57 patients undergoing panendoscopy and biopsy. Oxygen saturation, total hemoglobin concentration,and the reduced scattering coefficient were extracted. Differences in malignant and normal tissues were examined based on two different groupings: anatomical site and morphological tissue type.

    Optical biomarkers exhibited statistical differences between malignant and normal samples. Contrast was enhanced when parsing tissues by morphological classification rather than anatomical subtype for unpaired comparisons.

    Corresponding linear discriminant models using multiple optical biomarkers showed improved predictive ability when accounting for morphological classification, particularly in node-positive lesions. The false-positive rate was retrospectively found to decrease by 34.2% in morphologically- vs. anatomically-derived predictive models. In glottic tissue, the surgeon exhibited a false-positive rate of 45.7% while the device showed a lower false-positive rate of 12.4%. Additionally, comparisons of optical parameters were made to further understand the physiology of tumor staging and potential causes of high surgeon false-positive rates. Optical spectroscopy is a user friendly,non-invasive tool capable of providing quantitative information to discriminate malignant from normal head and neck tissues. Predictive models demonstrated promising results for real-time diagnostics. Furthermore, the strategy described appears to be well suited to reduce the clinical false-positive rate.

    Other authors
    See publication
  • Wavelength Optimization for Quantitative Spectral Imaging of Breast Tumor Margins

    PLOS ONE

    A wavelength selection method that combines an inverse Monte Carlo model of reflectance and a genetic algorithm for global optimization was developed for the application of spectral imaging of breast tumor margins. The selection of wavelengths impacts system design in cost, size, and accuracy of tissue quantitation. The minimum number of wavelengths required for the accurate quantitation of tissue optical properties is 8, with diminishing gains for additional wavelengths. The resulting…

    A wavelength selection method that combines an inverse Monte Carlo model of reflectance and a genetic algorithm for global optimization was developed for the application of spectral imaging of breast tumor margins. The selection of wavelengths impacts system design in cost, size, and accuracy of tissue quantitation. The minimum number of wavelengths required for the accurate quantitation of tissue optical properties is 8, with diminishing gains for additional wavelengths. The resulting wavelength choices for the specific probe geometry used for the breast tumor margin spectral imaging application were tested in an independent pathology-confirmed ex vivo breast tissue data set and in tissue-mimicking phantoms. In breast tissue, the optical endpoints (hemoglobin, β-carotene, and scattering) that provide the contrast between normal and malignant tissue specimens are extracted with the optimized 8-wavelength set with <9% error compared to the full spectrum (450–600 nm). A multi-absorber liquid phantom study was also performed to show the improved extraction accuracy with optimization and without optimization. This technique for selecting wavelengths can be used for designing spectral imaging systems for other clinical applications.

    Other authors
    See publication
  • A diffuse reflectance spectral imaging system for tumor margin assessment using custom annular photodiode arrays

    Biomedical Optics Express

    Diffuse reflectance spectroscopy (DRS) is a well-established method to quantitatively distinguish between benign and cancerous tissue for tumor margin assessment. Current multipixel DRS margin assessment tools are bulky fiber-based probes that have limited scalability. Reported herein is a new approach to multipixel DRS probe design, which utilizes direct detection of the DRS signal by using optimized custom photodetectors in direct contact with the tissue. This first fiberless DRS imaging…

    Diffuse reflectance spectroscopy (DRS) is a well-established method to quantitatively distinguish between benign and cancerous tissue for tumor margin assessment. Current multipixel DRS margin assessment tools are bulky fiber-based probes that have limited scalability. Reported herein is a new approach to multipixel DRS probe design, which utilizes direct detection of the DRS signal by using optimized custom photodetectors in direct contact with the tissue. This first fiberless DRS imaging system for tumor margin assessment consists of a 4 × 4 array of annular silicon photodetectors and a constrained free-space light delivery tube optimized to deliver light across a 256 mm2 imaging area. This system has 4.5 mm spatial resolution. The signal-to-noise ratio measured for normal and malignant breast tissue-mimicking phantoms was 35 dB to 45 dB for λ = 470 nm to 600 nm.

    Other authors
    • Sulochana Dhar
    • Gregory Palmer
    • Martin Brooke
    • Brandon Nichols
    • Bing Yu
    • Nirmala Ramanujam
    • Nan M. Jokerst
    See publication
  • Diffuse reflectance spectral imaging for breast tumor margin assessment

    Proceedings of SPIE

    Diffuse reflectance spectroscopy has been previously explored as a promising method for providing real-time visual maps of tissue composition to help surgeons determine breast lumpectomy margins and to ensure the complete removal of a tumor during surgery. We present the simple design, validation, and implementation of a compact and cost-effective spectral imaging system for the application of tumor margin assessment. Our new system consists of a broadband source with bandpass filters for…

    Diffuse reflectance spectroscopy has been previously explored as a promising method for providing real-time visual maps of tissue composition to help surgeons determine breast lumpectomy margins and to ensure the complete removal of a tumor during surgery. We present the simple design, validation, and implementation of a compact and cost-effective spectral imaging system for the application of tumor margin assessment. Our new system consists of a broadband source with bandpass filters for illumination and a fabricated custom 16-pixel photodiode imaging array for the detection of diffuse reflectance. The system prototype was characterized in tissue-mimicking phantoms and has an SNR of greater than 40 dB in phantoms, animals, and human tissue. We show proof-of-concept for performing fast, wide-field spectral imaging with a simple, inexpensive design. The strategy also allows for the scaling to higher pixel number and density in future iterations of the system.

    Other authors
    See publication
  • A compact, cost-effective diffuse reflectance spectroscopic imaging system for quantitative tissue absorption and scattering

    Proceedings of SPIE

    There is clinical utility for a wide-field, spectroscopic imaging device for quantitative tissue absorption and scattering in a number of applications. We present the design of a compact, cost-effective spectroscopic imaging system, which consists of a broadband source with bandpass filters and a light guide for illumination and an inexpensive array of silicon photodiodes for detection. A single-pixel version of the system was tested in liquid phantoms simulating a wide range of human breast…

    There is clinical utility for a wide-field, spectroscopic imaging device for quantitative tissue absorption and scattering in a number of applications. We present the design of a compact, cost-effective spectroscopic imaging system, which consists of a broadband source with bandpass filters and a light guide for illumination and an inexpensive array of silicon photodiodes for detection. A single-pixel version of the system was tested in liquid phantoms simulating a wide range of human breast tissue and optical properties can be extracted with absorption and reduced scattering errors of 12.6% and 4.7%, respectively. We show proof-of-concept for performing fast, wide-field spectroscopic imaging with a simple design. The design also allows for scaling and expansion into higher pixel number and density in future iterations of custom device design, which includes in-house photodiode array fabrication processes and integration of on-board current amplifier circuits.

    Other authors
    See publication
  • A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes

    Optics Express

    A diffuse reflectance spectroscopy system was modified as a step towards miniaturization and spectral imaging of tissue absorption and scattering. The modified system uses a tunable source and an optical fiber for illumination and a photodiode in contact with tissue for detection. Compared to the previous system, it is smaller, less costly, and has comparable performance in extracting optical properties in tissue phantoms. Wavelength reduction simulations show the feasibility of replacing the…

    A diffuse reflectance spectroscopy system was modified as a step towards miniaturization and spectral imaging of tissue absorption and scattering. The modified system uses a tunable source and an optical fiber for illumination and a photodiode in contact with tissue for detection. Compared to the previous system, it is smaller, less costly, and has comparable performance in extracting optical properties in tissue phantoms. Wavelength reduction simulations show the feasibility of replacing the source with LEDs to further decrease system size and cost. Simulated crosstalk analysis indicates that this evolving system can be multiplexed for spectral imaging in the future.

    Other authors
    See publication
  • Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo

    Journal of Biomedical Optics

    A hybrid optical device that uses a multimode fiber coupled to a tunable light source for illumination and a 2.4-mm photodiode for detection in contact with the tissue surface is developed as a first step toward our goal of developing a cost-effective, miniature spectral imaging device to map tissue optical properties in vivo. This device coupled with an inverse Monte Carlo model of reflectance is demonstrated to accurately quantify tissue absorption and scattering in tissue-like turbid…

    A hybrid optical device that uses a multimode fiber coupled to a tunable light source for illumination and a 2.4-mm photodiode for detection in contact with the tissue surface is developed as a first step toward our goal of developing a cost-effective, miniature spectral imaging device to map tissue optical properties in vivo. This device coupled with an inverse Monte Carlo model of reflectance is demonstrated to accurately quantify tissue absorption and scattering in tissue-like turbid synthetic phantoms with a wide range of optical properties. The overall errors for quantifying the absorption and scattering coefficients are 6.0±5.6 and 6.1±4.7%, respectively. Compared with fiber-based detection, having the detector right at the tissue surface can significantly improve light collection efficiency, thus reducing the requirement for sophisticated detectors with high sensitivity, and this design can be easily expanded into a quantitative spectral imaging system for mapping tissue optical properties in vivo.

    Other authors
    See publication
  • A Miniature Optical Device for Noninvasive, Fast Characterization of Tumor Pathology

    Biomedical Optics, OSA Technical Digest

    An optical spectroscopy system for cancer diagnostics is miniaturized. The performance of the device is validated with phantom studies. Absorption and scattering coefficients are extracted with high accuracy with an inverse Monte Carlo model.

    Other authors
    See publication

Patents

  • A Diffuse Reflectance Spectroscopy Device for Quantifying Tissue Absorption and Scattering

    Issued US WO2010042249

    A diffuse reflectance spectroscopy system for quantifying electromagnetic absorption and scattering in a tissue is provided. Also provided are optical probes and methods for imaging a tissue mass. In some embodiments, the methods include the steps of contacting a tissue mass with an optical probe, wherein the optical probe includes at least one entity for emitting light that interacts with a tissue mass and then is remitted to a collecting entity, for collecting the light that has interacted…

    A diffuse reflectance spectroscopy system for quantifying electromagnetic absorption and scattering in a tissue is provided. Also provided are optical probes and methods for imaging a tissue mass. In some embodiments, the methods include the steps of contacting a tissue mass with an optical probe, wherein the optical probe includes at least one entity for emitting light that interacts with a tissue mass and then is remitted to a collecting entity, for collecting the light that has interacted with the tissue mass, wherein the collecting entity comprises a detector comprising one or more photodiodes; measuring turbid spectral data of the tissue mass using the optical probe; converting the turbid spectral data to at least one of absorption and scattering spectral data via a Monte Carlo algorithm or a diffusion algorithm; and quantifying tissue compositions and scatterer size in a tissue mass using the at least one of absorption and scattering spectral data.

    Other inventors
    See patent

Recommendations received

More activity by Justin

View Justin’s full profile

  • See who you know in common
  • Get introduced
  • Contact Justin directly
Join to view full profile

Other similar profiles

Explore collaborative articles

We’re unlocking community knowledge in a new way. Experts add insights directly into each article, started with the help of AI.

Explore More

Others named Justin Lo in United States

Add new skills with these courses