TECHNICAL INFORMATION

URETHANES
PRODUCT NAME

HYDRO ACTIVE Soil


Hydrophobic Polyurethane Grout

PHYSICAL PROPERTIES
Uncured Solids Viscosity at 77F Color Density Flashpoint Corrosiveness Soil Cat 100% 25 - 35 cps Blackishbrown 9.33 lbs/gal 288F Noncorrosive Colorless liquid 5-18 cps 320F 8.75-9.17 lbs/gal 170 psi 1648 psi in sand 369 psi 184 psi 28 psi ASTM D 2369 B ASTM D 2196 A

MANUFACTURER
De Neef Construction Chemicals, Inc. 5610 Brystone Drive Houston, TX 77041 1(800) 732-0166

ASTM D 1475 ASTM D 93

PRODUCT DESCRIPTION
HYDRO ACTIVE Soil is a hydrophobic polyurethane that, when used alone or with HYDRO ACTIVE Soil Cat, is designed to increase the bearing capacity of permeable soil. In its uncured form, HYDRO ACTIVE Soil is a blackish-brown nonflammable liquid. When it comes in contact with water, the grout slightly expands and, depending on temperature and amount of accelerator (HYDRO ACTIVE Soil Cat) used, quickly cures to a very dense open cell foam that is essentially unaffected by corrosive environments and micro organisms.

Appearance Viscosity at 77F Flashpoint Cured Density Tensile Strength Compressive Strength Bending strength Shearing Strength Bond Strength to Bending bond strength Mortar Joints Shearing bond strength: Coefficient of Permeability Toxicity

ASTM D 2196 ASTM D 93 ASTM D 1475 ASTM D 190 63 Unconfined

APPROPRIATE APPLICATIONS
Stabilize soil beneath slabs and roadways Create below grade water cutoff curtain wall Confine below grade movement of hazardous materials Free Foam Expansion up to 3 times its liquid volume Contains no volatile solvents Very high strength with low creep Extremely low viscosity and controllable reactivity permit injection into tight soils (104 cm/sec)

326 psi 4.98x10


-6

Non-toxic

The data shown above reflects typical results based on laboratory testing under controlled conditions. Reasonable variations from the data shown above may result.

ADVANTAGES

* at 50F

* at 68F

* at 86F

Reactivity %HYDRO ACTIVE Soil Cat 0.5% 1.0% 1.5% 0.5% 1.0% 1.5% 0.5% 1.0% 1.5%

Geltime in minsec 15' 05" 7' 00" 3' 42" 11' 00" 5' 00" 2' 35" 6' 25" 3' 30" 1' 55"

Example - 1% Soil Cat =1.3 oz. per gallon of HYDRO ACTIVE Soil Note: Soil Cat must be agitated by shaking the can prior to adding to resin

5610 Brystone Dr. Houston, TX 77041Tel: 713-896-0123Fax: 713-849-3340www.deneef.com

PACKAGING

HYDRO ACTIVE Soil: 55 gallon metal drum sealed under dry nitrogen. 5 gal metal pail sealed under dry nitrogen. HYDRO ACTIVE Soil Cat Accelerator: 25 oz. cans. .

STORAGE & HANDLING


Store in dry area in original Resealable Containers. Warning! If HYDRO ACTIVE Soil Cat is allowed to freeze it will lower performance.

PRECAUTIONS
Always use protective clothing, gloves and goggles consistent with OSHA regulations during use. Avoid eye and skin contact. Do not ingest. Refer to Material Safety Data Sheet for detailed safety precautions.

LIMITATIONS
Low temperatures will significantly affect viscosity. If site temperatures are extremely low, heat bands or heated water baths may be used on the pails before and during installation to maintain the products temperature. Avoid splashing water into open containers, as the material is water activated. Avoid exceeding 90F when warming.

SAFETY INFORMATION
In the event of an EMERGENCY call: CHEM-TREC 800-424-9300.

WARRANTY INFORMATION
De Neef Construction Chemicals, Inc. products are warranted under the policy set forth under the WARRANTY section of the De Neef Construction Chemicals Inc., product catalog. Warranty information can also be obtained via the De Neef Construction Chemicals Inc. website at www.deneef.com, or by calling 713-896-0123 or toll free at 1-800-732-0166.
Rev. 11/2008

CAUTION pH NOTICE. Water used to activate HYDRO ACTIVE Grouts must be in a range of pH 3 10 for optimum foam quality. SURFACE PREPARATION
Refer to DeNeef Surface Guidelines for more details. Preparation

INSTALLATION PROCEDURES
Prior to installation both the grout and accelerator must be agitated separately before combining by vigorously shaking or mixing. The grout should never be used with more HYDRO ACTIVE Soil Cat than the amount recommended on this data sheet. Excess acceleration will cause a vigorous expansion that is prone to shrinkage. Pour the desired amount of HYDRO ACTIVE Soil into a clean pail. Measure the appropriate amount of HYDRO ACTIVE Soil Cat and pour it into the HYDRO ACTIVE Soil and stir until adequately mixed. During injection the grout will follow the path of least resistance. When the material has stopped penetrating it will continue to expand against the confines of the crack/joint and compress within itself, forming a very dense, open cell material stopping the leak. For application procedures in extreme temperatures and specific environments or equipment recommendations call the De Neef Technical Service Department.