Wood Group ESP Catalogue
Wood Group ESP Catalogue
VII
Product Data Book
Wood Group ESP
5500 S.E. 59th Street
Oklahoma City, OK 73135
Tel 405-670-1431
www.woodgroup-esp.com
Wood Group-ESP 2009
2
TERM DEFINITIONS
TERM DEFINITION
C Degrees Celcius
F Degrees Farenheit
AC Alternating current
ASD Adjustable speed drive
COMM Communications
DC Direct current
DPF Displacement power factor
ESP Electric submersible pump
I/O Inputs / Outputs
IEC International electric code
IGBT Insulated gate bi-polar transistor
ISO International Organization for Standardization
LCD Liquid crystal display
MODBUS Serial Communication Protocol
PI Proportional Integral
PCP Progressing cavity pump
SCADA Supervisory Control and Data Acquisition
SPS Surface pumping systems
THD Total harmonic distortion
TVSS Transient voltage surge suppression
VAC Volts AC
VDC Volts DC
VFD Variable frequency drive
VSD Variable speed drive
VSG
VII
without VSG
VII
without VSG
VII
Variable Speed Drive (VSD)
available from Wood Group ESP. Information is provided on available ratings, physical size,
product features, general operation, and available options. Additional details regarding drive
set-up, operation, and troubleshooting are available in the Vector VII Variable Speed Drive
Users Manual. The descriptions and information contained in this publication are for
informational purposes only and should not be used to install, set-up, program, or operate the
Vector VII drive.
Note: This publication describes the standard Vector VII Variable Speed Drive and includes
descriptions of the most common drive options and modifications. Specific features may be
added (or disabled) from the product depending on the specific application. All specifications
and information contained in this publication are subject to change without notice.
DRIVE DESCRIPTION
The Vector VII Variable Speed Drive is designed specifically for oil-field pumping applications
including electrical submersible pumps (ESP) and surface pumping systems (SPS). Vector VII
drives are available in ratings from 104 KVA to1500 KVA. They are provided in rugged outdoor
rated enclosures designed for a wide variety of environments ranging from arctic to desert
conditions. Application specific software and a Wood Group ESP Custom Operator Control
Panel combine to optimize pump control while simplifying drive operation.
Vector VII uses the latest Insulated Gate Bipolar Transistor (IGBT) technology in combination
with surface mount printed circuit boards to create a VSD of the highest reliability, and small
physical size. Fixed voltage, three-phase AC input power is first converted to a fixed DC bus
voltage by the input rectifier section of the drive. That fixed DC bus voltage is then processed
by the inverter section to produce a sine coded variable voltage, variable frequency output to
control the speed of the motor.
For ESP applications, the Vector VII Variable Speed Drive is available with integrated VSG
Technology. With VSG Technology the drive output voltage waveform is a near perfect sine-
wave which results in improved motor performance, extended motor run life, extended motor
cable life, and increased operational efficiency in the driven equipment. Vector VII drives with
VSG (Variable Sinewave Generation) technology can successfully operate with motor cable
lengths up to 15,000 ft.
User adjustments include operating speed, acceleration and deceleration rates, motor overload
protection settings, auto restarts, time delays, and stopping methods. Control methods include
frequency control, current control, pressure control, or analog follower (Analog 1 = 0-10 VDC,
Analog 2 = 0-10 VDC or 4-20 mA) capability.
Wood Group-ESP 2009
6
VECTOR VII PRODUCT SUMMARY
Standard Drive Features:
Ratings from 104 KVA to 1500 KVA.
Specifically designed for oil field pumping applications.
NEMA 3R outdoor enclosure, rugged (10 Gauge) steel construction with compact footprint.
Enclosure base pre-drilled with slotted holes for permanent attachment to foundation.
Three point door latching mechanism.
Designed for 50C (122 F) ambient temperature, white enclosure reduces solar heating.
Input AC line circuit breaker with pad lockable flange mount external operator.
State of the art operator control panel with graphical interface.
Available with or without Variable Sinewave Generator (VSG) technology pure sine wave output.
Latest generation IGBTs (Insulated Gate Bipolar Transistors).
Microprocessor based control circuitry with non-volatile memory for all drive parameters.
Surface mount technology with protective coating on all printed circuit boards.
Input line transient voltage suppression - line to line and line to ground voltage surge protection.
Six pulse input rectification (standard) or optional multi-pulse rectification for reduced AC line harmonics.
Fused control power transformer.
Extended acceleration time - reduces electrical and mechanical stress on pump and motor.
S curve soft start / soft stop capability.
Power loss ride through capability.
Operator Panel Features:
Intuitive operator friendly menu is easy to use.
Large bright screen is easy to read in direct sunlight.
Built in real time clock provides time and date stamp for historical data and event logger.
Operator control panel monitors both drive parameters and well parameters.
Note: Wood Group ESP downhole sensor is required to monitor well parameters.
Drive and well parameters are displayed in engineering units using plain language text.
User programmable functions and operating modes.
Set point PI control closed loop programmable in engineering units.
Comprehensive run status screen shows critical drive and well data in a single location.
Time stamped event and fault log - stores last 256 drive events including faults, starts, stops, operator
changes, etc.
Historical data log - periodically samples and stores the values of 20 different drive and well parameters.
- All parameters are time (to the second) and date stamped with 35 days of data retained.
Trending screen graphically displays historical data for important drive and well parameters.
Software embedded circular recording ammeter high resolution display with 1 day or 7 day format.
Drive Status Lights
- Shows drive operating mode and are visible from a distance.
Software embedded drive lock-out and auto-restart switches.
Programmable restart capability.
USB port for data retrieval and transfer of drive information to memory stick.
- Save historical data, event log information, recording ammeter data, and drive configuration
information.
Built in Modbus communications port easy interface to customer SCADA systems.
Multiple Languages
Password protection to prevent unauthorized changes.
Wood Group-ESP 2009
7
Protective Features:
Input phase insensitive sequencing of 3 phase input power is not necessary.
DC bus reactor.
Diagnostic fault indication.
Loss of load detection.
Serial communication loss detection.
Short circuit protection.
Ground fault protection.
Loss of input phase protection.
Over voltage and under voltage protection.
Over current and under current protection.
Current limiting DC bus fuse.
Motor stall protection.
Heat sink over temperature protection.
Adjustable motor current limit.
Critical frequency avoidance three selectable frequencies with adjustable bandwidth.
Electrical Specifications:
Rated Input Voltage: 480 Volt, 3 phase, 60 Hz (+ / - 10% of rated voltage and frequency).
Consult factory for other input voltages and frequency ratings.
Efficiency: 97% or greater at full load.
Power Factor: .95 or greater Constant over operating range Not speed or load dependent
Output Voltage: 0 Volts to rated input voltage
Output Frequency: 0 Hertz to 120 Hertz.
Control Specifications:
Control Method: Sine coded output with optional VSG (Variable Sinewave Generation)
technology.
Accel / Decel: 0 Seconds to 6,000 seconds.
Drive Overload: 110% of drive rating for 60 seconds (Variable Torque).
Current Limit: Programmable current limit.
Control I/O:
Digital Inputs: 7 Programmable inputs - 24 VDC, 8 mA Sinking or Sourcing Logic.
Digital Outputs: 2 Programmable dry contacts rated 250 VAC / 30 VDC @ 1A.
1 Fault contact - Form C dry contact rated 250 VAC / 30 VDC @ 1A.
Analog Inputs: 2 Programmable inputs (10 bit).
Analog 1 = 0 to +10 VDC 20 K Ohms
Analog 2 = 0 to +10 VDC 20 K Ohms or 4 to 20 mA 250 Ohms
Analog Outputs: 2 Programmable outputs (10 bit) each = 0 to +10 VDC 2 mA.
Analog Reference: +15 VDC Source 20 mA.
Logic Reference: +24 VDC Source 8 mA.
Environmental Specifications:
Ambient Service Temperature: 0C to 50C (32F to 122F)
to -40C (-40F) with optional arctic package.
Ambient Storage Temperature: -20C to 60C (-4F to 140F)
Humidity: 0 to 100%
Altitude: Up to 1000 Meters (3300 Feet) without de-rate.
Vibration: 9.81m/s
2
(1 G) maximum at 10 to 20 Hz, 2.0 m/s
2
(0.2 G) at 20 Hz to 50 Hz.
Wood Group-ESP 2009
8
Various Installation Examples
ESP Installation SPS Installation
ESP Installation
ESP Installation Offshore Installation
Wood Group-ESP 2009
9
CATALOG NUMBER EXPLANATION
Position A B C D E F G H to Z
Description
Drive
Type
Rated
Amps
Rated
Volts
Rated
Hertz
Pulse
Enclosure
Type
Output
Type
Options
Example V7 - 675A - 480V - 60HZ - 6P - N3R - VSG - AP
Position
Description
Choices
A Vector 7 Drive V7
B Output Amps 180A, 304A, 414A, 515A, 675A, 910A, 1215A,
1366A, 1444A, 1821A, Other
C Input Voltage 480VAC, 380VAC, 400VAC, Other
D Input Frequency 60HZ, 50HZ
E Input Type 6P = 6 Pulse, 12P = 12 Pulse, 18P = 18 Pulse,
Other
F Enclosure Type N3R = Nema 3R, N1 = Nema 1, Other
G Output Type VSG = Sine Wave, No Entry = PWM
H Z Options See Options Table on Page 14
Wood Group-ESP 2009
10
VECTOR VII RATINGS AND CATALOG NUMBERS
Vector VII Drives without VSG (5) - 480 VAC / 60 Hertz
Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136
V7-124A-480V-60HZ-12P-N3R (3)
104 12 480 124 480 136 (1)
V7-124A-480V-60HZ-18P-N3R (3)
104 18 480 124 480 136 (2)
V7-180A-480V-60HZ-6P-N3R 150 6 480 180 480 198
V7-180A-480V-60HZ-12P-N3R (3) 150 12 480 180 480 198 (1)
V7-180A-480V-60HZ-18P-N3R (3) 150 18 480 180 480 198 (2)
V7-240A-480V-60HZ-6P-N3R 200 6
480
240 480 264
V7-240A-480V-60HZ-12P-N3R (4)
200 12
480 240
480
264 (1)
V7-240A-480V-60HZ-18P-N3R (4)
200 18
480 240
480
264 (2)
V7-304A-480V-60HZ-6P-N3R 253 6 480 304 480 334
V7-304A-480V-60HZ-12P-N3R (3) 253 12 480 304 480 334 (1)
V7-304A-480V-60HZ-18P-N3R (3) 253 18 480 304 480 334 (2)
V7-414A-480V-60HZ-6P-N3R 344 6 480 414 480 456
V7-414A-480V-60HZ-12P-N3R (3) 344 12 480 414 480 456 (1)
V7-414A-480V-60HZ-18P-N3R (3) 344 18 480 414 480 456 (2)
V7-515A-480V-60HZ-6P-N3R 428 6 480 515 480 567
V7-515A-480V-60HZ-12P-N3R (3) 428 12 480 515 480 567 (1)
V7-515A-480V-60HZ-18P-N3R (3) 428 18 480 515 480 567 (2)
V7-675A-480V-60HZ-6P-N3R 561 6 480 675 480 743
V7-675A-480V-60HZ-12P-N3R (3) 561 12 480 675 480 743 (1)
V7-675A-480V-60HZ-18P-N3R (3) 561 18 480 675 480 743 (2)
V7-910A-480V-60HZ-6P-N3R 757 6 480 910 480 1000
V7-910A-480V-60HZ-12P-N3R (3) 757 12 480 910 480 1000 (1)
V7-910A-480V-60HZ-18P-N3R (3) 757 18 480 910 480 1000 (2)
V7-1215A-480V-60HZ-6P-N3R 1010 6 480 1215 480 1340
V7-1215A-480V-60HZ-12P-N3R (3) 1010 12 480 1215 480 1340 (1)
V7-1215A-480V-60HZ-18P-N3R (3) 1010 18 480 1215 480 1340 (2)
V7-1366A-480V-60HZ-6P-N3R 1136 6 480 1366 480 1500
V7-1366A-480V-60HZ-12P-N3R (3) 1136 12 480 1366 480 1500 (1)
V7-1366A-480V-60HZ-18P-N3R (3) 1136 18 480 1366 480 1500 (2)
V7-1444A-480V-60HZ-6P-N3R 1200 6 480 1444 480 1590
V7-1444A-480V-60HZ-12P-N3R (3) 1200 12 480 1444 480 1590 (1)
V7-1444A-480V-60HZ-18P-N3R (3) 1200 18 480 1444 480 1590 (2)
V7-1821A-480V-60HZ-6P-N3R 1514 6 480 1821 480 2000
V7-1821A-480V-60HZ-12P-N3R (3) 1514 12 480 1821 480 2000 (1)
V7-1821A-480V-60HZ-18P-N3R (3) 1514 18 480 1821 480 2000 (2)
(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 480 VAC.
(5) VSG is required for ESP applications.
Wood Group-ESP 2009
11
VECTOR VII RATINGS AND CATALOG NUMBERS
Vector VII Drives with VSG - 480 VAC / 60 Hertz
Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136
V7-124A-480V-60HZ-12P-N3R (3)
104 12 480 124 480 136 (1)
V7-124A-480V-60HZ-18P-N3R (3)
104 18 480 124 480 136 (2)
V7-180A-480V-60HZ-6P-N3R-VSG 150 6 480 180 480 198
V7-180A-480V-60HZ-12P-N3R-VSG (3) 150 12 480 180 480 198 (1)
V7-180A-480V-60HZ-18P-N3R-VSG (3) 150 18 480 180 480 198 (2)
V7-240A-480V-60HZ-6P-N3R-VSG 200 6
480
240 480 264
V7-240A-480V-60HZ-12P-N3R-VSG (3)
200 12
480 240
480
264 (1)
V7-240A-480V-60HZ-18P-N3R-VSG (3)
200 18
480 240
480
264 (2)
V7-304A-480V-60HZ-6P-N3R-VSG 253 6 480 304 480 334
V7-304A-480V-60HZ-12P-N3R-VSG (3) 253 12 480 304 480 334 (1)
V7-304A-480V-60HZ-18P-N3R-VSG (3) 253 18 480 304 480 334 (2)
V7-414A-480V-60HZ-6P-N3R-VSG 344 6 480 414 480 456
V7-414A-480V-60HZ-12P-N3R-VSG (3) 344 12 480 414 480 456 (1)
V7-414A-480V-60HZ-18P-N3R-VSG (3) 344 18 480 414 480 456 (2)
V7-515A-480V-60HZ-6P-N3R-VSG 428 6 480 515 480 567
V7-515A-480V-60HZ-12P-N3R-VSG (3) 428 12 480 515 480 567 (1)
V7-515A-480V-60HZ-18P-N3R-VSG (3) 428 18 480 515 480 567 (2)
V7-675A-480V-60HZ-6P-N3R-VSG 561 6 480 675 480 743
V7-675A-480V-60HZ-12P-N3R-VSG (3) 561 12 480 675 480 743 (1)
V7-675A-480V-60HZ-18P-N3R-VSG (3) 561 18 480 675 480 743 (2)
V7-910A-480V-60HZ-6P-N3R-VSG 757 6 480 910 480 1000
V7-910A-480V-60HZ-12P-N3R-VSG (3) 757 12 480 910 480 1000 (1)
V7-910A-480V-60HZ-18P-N3R-VSG (3) 757 18 480 910 480 1000 (2)
V7-1215A-480V-60HZ-6P-N3R-VSG 1010 6 480 1215 480 1340
V7-1215A-480V-60HZ-12P-N3R-VSG (3) 1010 12 480 1215 480 1340 (1)
V7-1215A-480V-60HZ-18P-N3R-VSG (3) 1010 18 480 1215 480 1340 (2)
V7-1366A-480V-60HZ-6P-N3R-VSG 1136 6 480 1366 480 1500
V7-1366A-480V-60HZ-12P-N3R-VSG (3) 1136 12 480 1366 480 1500 (1)
V7-1366A-480V-18P-N3R-VSG (3) 1136 18 480 1366 480 1500 (2)
V7-1444A-480V-60HZ-6P-N3R-VSG 1200 6 480 1444 480 1590
V7-1444A-480V-60HZ-12P-N3R-VSG (3) 1200 12 480 1444 480 1590 (1)
V7-1444A-480V-60HZ-18P-N3R-VSG (3) 1200 18 480 1444 480 1590 (2)
V7-1821A-480V-60HZ-6P-N3R-VSG 1514 6 480 1821 480 2000
V7-1821A-480V-60HZ-12P-N3R-VSG (3) 1514 12 480 1821 480 2000 (1)
V7-1821A-480V-60HZ-18P-N3R-VSG (3) 1514 18 480 1821 480 2000 (2)
(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 480 VAC.
(5) VSG is required for ESP applications.
Wood Group-ESP 2009
12
VECTOR VII RATINGS AND CATALOG NUMBERS
Vector VII Drives without VSG (5) - 380 VAC / 50 Hertz
Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136
V7-124A-480V-50HZ-12P-N3R (3)
82 12 380 124 380 136 (1)
V7-124A-480V-50HZ-18P-N3R (3)
82 18 380 124 380 136 (2)
V7-180A-380V-50HZ-6P-N3R 118 6 380 180 380 198
V7-180A-380V-50HZ-12P-N3R (3)
118
12
380
180
380
198 (1)
V7-180A-380V-50HZ-18P-N3R (3)
118
18
380
180
380
198 (2)
V7-240A-380V-50HZ-6P-N3R 158 6
380
240
380
264
V7-240A-380V-50HZ-12P-N3R (3) 158
12
380 240 380 264 (1)
V7-240A-380V-50HZ-18P-N3R (3) 158
18
380 240 380 264 (2)
V7-304A-380V-50HZ-6P-N3R 200 6
380
304
380
334
V7-304A-380V-50HZ-12P-N3R (3) 200 12
380
304
380
334 (1)
V7-304A-380V-50HZ-18P-N3R (3) 200 18
380
304
380
334 (2)
V7-414A-380V-50HZ-6P-N3R 272 6
380
414
380
456
V7-414A-380V-50HZ-12P-N3R (3) 272 12
380
414
380
456 (1)
V7-414A-380V-50HZ-18P-N3R (3) 272 18
380
414
380
456 (2)
V7-515A-380V-50HZ-6P-N3R 338 6
380
515
380
567
V7-515A-380V-50HZ-12P-N3R (3) 338 12
380
515
380
567 (1)
V7-515A-380V-50HZ-18P-N3R (3) 338 18
380
515
380
567 (2)
V7-675A-380V-50HZ-6P-N3R 444 6
380
675
380
743
V7-675A-380V-50HZ-12P-N3R (3) 444 12
380
675
380
743 (1)
V7-675A-380V-50HZ-18P-N3R (3) 444 18
380
675
380
743 (2)
V7-819A-380V-50HZ-6P-N3R 539 6
380
819
380
901
V7-819A-380V-50HZ-12P-N3R (3) 539 12
380 819 380
901 (1)
V7-819A-380V-50HZ-18P-N3R (3) 539 18
380 819 380
901 (2)
V7-1093A-380V-50HZ-6P-N3R 719 6
380
1093
380
1202
V7-1093A-380V-50HZ-12P-N3R (3) 719 12
380 1093 380
1202 (1)
V7-1093A-380V-50HZ-18P-N3R (3) 719 18
380 1093 380
1202 (2)
V7-1229A-380V-50HZ-6P-N3R 809 6
380
1229
380
1352
V7-1229A-380V-50HZ-12P-N3R (3) 809 12
380 1229 380
1352 (1)
V7-1229A-380V-50HZ-18P-N3R (3) 809 18
380 1229 380
1352 (2)
V7-1300A-380V-50HZ-6P-N3R 856 6
380
1300
380
1430
V7-1300A-380V-50HZ-12P-N3R (3) 856 12
380 1300 380
1430 (1)
V7-1300A-380V-50HZ-18P-N3R (3) 856 18
380 1300 380
1430 (2)
V7-1639A-380V-50HZ-6P-N3R 1079 6
380
1639
380
1803
V7-1639A-380V-50HZ-12P-N3R (3) 1079 12
380 1639 380
1803 (1)
V7-1639A-380V-50HZ-18P-N3R (3) 1079 18
380 1639 380
1803 (2)
(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 380 VAC.
(5) VSG is required for ESP applications.
Wood Group-ESP 2009
13
VECTOR VII RATINGS AND CATALOG NUMBERS
Vector VII Drives with VSG - 380 VAC / 50 Hertz
Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136
V7-124A-480V-50HZ-12P-N3R (3)
82 12 380 124 380 136 (1)
V7-124A-480V-50HZ-18P-N3R (3)
82 18 380 124 380 136 (2)
V7-180A-380V-50HZ-6P-N3R-VSG 118 6 380 180
380
198
V7-180A-380V-50HZ-12P-N3R-VSG (3)
118
12
380
180
380
198 (1)
V7-180A-380V-50HZ-18P-N3R-VSG (3)
118
18
380
180
380
198 (2)
V7-240A-380V-50HZ-6P-N3R-VSG 158 6
380
240
380
264
V7-240A-380V-50HZ-12P-N3R-VSG (3) 158
12
380 240 380 264 (1)
V7-240A-380V-50HZ-18P-N3R-VSG (3) 158
18
380 240 380 264 (2)
V7-304A-380V-50HZ-6P-N3R-VSG 200 6
380
304
380
334
V7-304A-380V-50HZ-12P-N3R-VSG (3) 200 12
380
304
380
334 (1)
V7-304A-380V-50HZ-18P-N3R-VSG (3) 200 18
380
304
380
334 (2)
V7-414A-380V-50HZ-6P-N3R-VSG 272 6
380
414
380
456
V7-414A-380V-50HZ-12P-N3R-VSG (3) 272 12
380
414
380
456 (1)
V7-414A-380V-150HZ-8P-N3R-VSG (3) 272 18
380
414
380
456 (2)
V7-515A-380V-50HZ-6P-N3R-VSG 338 6
380
515
380
567
V7-515A-380V-50HZ-12P-N3R-VSG (3) 338 12
380
515
380
567 (1)
V7-515A-380V-50HZ-18P-N3R-VSG (3) 338 18
380
515
380
567 (2)
V7-675A-380V-50HZ-6P-N3R-VSG 444 6
380
675
380
743
V7-675A-380V-50HZ-12P-N3R-VSG (3) 444 12
380
675
380
743 (1)
V7-675A-380V-50HZ-18P-N3R-VSG (4) 444 18
380
675
380
743 (2)
V7-819A-380V-50HZ-6P-N3R-VSG 539 6
380
819
380
901
V7-819A-380V-50HZ-12P-N3R-VSG (3) 539 12
380 819 380
901 (1)
V7-819A-380V-50HZ-18P-N3R-VSG (3) 539 18
380 819 380
901 (2)
V7-1093A-380V-50HZ-6P-N3R-VSG 719 6
380
1093
380
1202
V7-1093A-380V-50HZ-12P-N3R-VSG(3) 719 12
380 1093 380
1202 (1)
V7-1093A-380V-50HZ-18P-N3R-VSG(3) 719 18
380 1093 380
1202 (2)
V7-1229A-380V-50HZ-6P-N3R-VSG 809 6
380
1229
380
1352
V7-1229A-380V-50HZ-12P-N3R-VSG(3) 809 12
380 1229 380
1352 (1)
V7-1229A-380V-50HZ-18P-N3R-VSG(3) 809 18
380 1229 380
1352 (2)
V7-1300A-380V-50HZ-6P-N3R-VSG 856 6
380
1300
380
1430
V7-1300A-380V-50HZ-12P-N3R-VSG(3) 856 12
380 1300 380
1430 (1)
V7-1300A-380V-50HZ-18P-N3R-VSG(3) 856 18
380 1300 380
1430 (2)
V7-1639A-380V-50HZ-6P-N3R-VSG 1079 6
380
1639
380
1803
V7-1639A-380V-50HZ-12P-N3R-VSG(3) 1079 12
380 1639 380
1803 (1)
V7-1639A-380V-50HZ-18P-N3R-VSG(3) 1079 18
380 1639 380
1803 (2)
(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 380 VAC.
(5) VSG is required for ESP applications.
Wood Group-ESP 2009
14
OPTIONS TABLE
Factory Installed options include:
Code Name Ratings Description
P12 12 Pulse Field
Conversion Kit
150 -
561
Allows conversion of 6 pulse drive to a 12 pulse
drive in the field.
SH Space Heater All Prevents condensation from forming inside the
drive enclosure. Generally not suitable for
enclosure heating in cold climates.
AP Arctic Package All Provides thermostatically controlled enclosure
heaters and ventilation control for operation to
-40C (-40F).
DP Desert Package All Provides added protection to reduce solar
heating in desert applications.
AOC Analog Output
Converter
All Converts the two 0 to +/- 10V Analog Outputs
on Vector VII to 4 to 20 ma outputs.
DIC Digital Input Converter All Converts the seven 24 V DC Digital Inputs on
Vector VII to 120 VAC Digital Inputs.
TVSS Transient Voltage
Surge Suppression
All Provides additional (very robust) protection
against voltage transients and surges.
PJB Power Junction Box All For added convenience all drive power
connections (3-phase drive input and motor
output plus a ground connection) are wired to
terminal blocks in a junction box mounted on
the side of the drive enclosure.
TBX Terminal Block With
Oversized Terminals
All Provides Customer I/O Interface terminal block
with larger than standard terminals.
VCS RTU RTU for SPS Use ALL Provides Additional AI / AO and DI / DO
ES E-Stop All Provides emergency stop of drive.
DSI DownHole Sensor
Interface
All Provides interface to SmartGuard
downhole
sensor via drive Operator Control Panel.
COMM1 Wireless Router
Communications
All Provides remote user interface to drive via a
wireless computer connection.
COMM2 Satellite Interface All Provides SCADA interface to the drive via
satellite.
ETI Ethernet Interface ALL Provides Interface from drive to Ethernet
system.
SST Stainless Steel
Construction
All Provides corrosion resistance in adverse
operating conditions such as offshore platforms.
BGP Brass Gland Plate ALL For Offshore / Marine Use
CE CE Certification 105-561 Complies with European Union Certification
UL / CUL UL Certification
CUL Certification
105-561
NVSG
Complies with Underwriters Laboratory
Requirements for United States and Canada
Consult Factory for other options.
Wood Group-ESP 2009
15
MANUFACTURER QUALIFICATIONS
Wood Group ESP has been a supplier of drives for many years. Our drives are installed in a
variety of oilfield pumping applications, both onshore and offshore. These include Electric
Submersible Pumps (ESP), Surface Pumping Systems (SPS), and Progressing Cavity Pump
(PCP) applications.
Wood Group ESPs experience with a wide variety of different oilfield pumping applications has
given us the unique ability to develop a specialized drive product for the markets we serve. Our
drives include application specific software and a custom Operator Control Panel that provides a
common, easy to use operator interface to both the drives parameters and the downhole or
process sensors associated with the application.
Wood Group ESP can provide stand alone drives for indoor or outdoor environments or we can
provide complete skid mounted packages including transformers that are easy to install and
transport. We can also provide a total drive solution that includes switchgear, transformers, and
a modular E-House complete with environmental controls and fire suppression systems.
MANUFACTURER CERTIFICATIONS
Wood Group ESP is an ISO 9001 certified company. This ensures that all quality and corrective
action procedures are documented and implemented to ensure the highest level of product
quality. At Wood Group ESP our goal is complete customer satisfaction.
GENERAL SPECIFICATIONS / OPERATING CONDITIONS / DESIGN FEATURES
Input Power Requirements:
The Wood Group ESP Vector VII drive is designed to accept three phase input power within a
voltage range of 480 VAC, +/- 10%. Optionally the Vector VII drive can be configured to accept
some other standard input voltage such as 380 VAC, +/- 10% or 400 VAC +/- 10%. The input
frequency requirement of the Vector VII drive is either 50 Hz +/- 5% or 60 Hz +/- 5%. Consult
factory for all voltage requirements other than 480 VAC / 60 Hz.
The Vector VII drive has a 6 pulse input as standard and can also be supplied with an optional
12 pulse, or 18 pulse input rectifier for reduced Input AC line harmonics. These drive
configurations will require a special input phase shifting transformer (consult factory for
transformer requirements on all 12 pulse and 18 pulse applications). See harmonic mitigation
section (page 30) for details on the benefits of multi-pulse drives.
Electrical Noise Immunity:
Noise immunity is in accordance with IEC61800-3.
Wood Group-ESP 2009
16
Output Power Characteristics:
The Vector VII drive is designed to produce an adjustable voltage, adjustable frequency output
to vary the speed of an AC induction motor. Output voltage is adjustable from 0 to 100% of the
applied input voltage. Output frequency is adjustable from 0 hertz to 120 hertz.
The inverter section produces a sine coded output waveform using proven IGBT technology.
For applications requiring a sinewave output, optional Variable Sinewave Generator (VSG)
technology is available. VSG technology minimizes the effects of reflected waves caused by
long cable lengths. With VSG technology motors may be successfully operated using cable
lengths up to 15,000 feet.
Power Conditioning:
An input isolation transformer is not required for protection from normal line transients.
Overload Capability:
Vector VII drives will produce 110% of rated output current for 1 minute.
Efficiency:
Vector VII drive efficiency is 97% or higher at full load and full speed.
Enclosure Features:
NEMA 3R outdoor rated.
10 gauge welded steel construction.
Multi-stage paint process including iron phosphate wash for adhesion and white epoxy
top coat.
Lifting eyes.
Lockable door handle and flange mount external circuit breaker disconnect handle.
Door mounted Operator Control Panel - all drive adjustments can be made with the
enclosure door closed.
Hardware:
The Vector VII employs the following power components:
Diode Input 6 Pulse, 12 Pulse, and 18 Pulse configurations available.
Inverter Section with the latest generation IGBT power devices
DC bus inductor included on all ratings.
Phase to phase and phase to ground MOV protection.
Plug-in connections on printed circuit boards.
Microprocessor based inverter logic isolated from power circuits.
Operator Control Panel is common for all KVA ratings. Interface includes a large LCD
graphical display with programming keys.
Common control connections for all ratings.
Wood Group-ESP 2009
17
Control Logic:
The drive is programmable or self adjusting for operation under the following conditions:
Operate drive with motor disconnected.
Controlled shut down, with no component failure in the event of an output phase to
phase or phase to ground short circuit and annunciation of the fault condition.
Multiple programmable stop modes including - Ramp, Coast, Ramp-to-Hold, and
S-curve.
Multiple acceleration and deceleration rates.
Terminal Blocks:
Separate terminal blocks are provided for control and power wiring. Optional power junction
boxes offer additional installation convenience.
Control Inputs and Outputs:
Digital Inputs: 7 programmable inputs - 24 VDC, 8 ma sinking or sourcing logic
Digital Outputs: 2 programmable dry contacts rated 250 VAC / 30 VDC @ 1A
1 fault contact - form C dry contact rated 250 VAC / 30 VDC @ 1A
Analog Inputs: 2 programmable Inputs (10 bits)
Analog 1 = 0 to +10 VDC 20 K ohms
Analog 2 = 0 to +10 VDC 20 K ohms or 4 to 20 mA 250 ohms
Analog Outputs: 2 programmable outputs (10 bits) each = 0 to +10 VDC 2 mA
Analog Reference: +15 VDC source 20 mA
Logic Reference: +24 VDC source 8 mA
Customer Interface: Digital & Analog I/O
Wood Group-ESP 2009
18
Reference Signals:
The Vector VII drive is usually configured to be controlled locally using the door mounted Oper-
ator Control Panel. Reference signals can also come from a remote controller when the Vector
VII drive is connected to an external SCADA system. Vector VII can also be configured to follow
other reference signals including analog input signals as listed below.
1. Remote potentiometer
2. 0-10 VDC
3. 4-20 ma
Loss of Reference:
The Vector VII drive can be configured to compensate for loss of its external frequency
command. This command is considered lost if the drive reference drops to 10% of its value in
400 ms or less. Drive loss of reference can be programmed from 0 to 100% of drives speed
command setting. Factory default setting is 80% of speed command.
Power Loss Ride Through Capability:
The Vector VII drive is capable of riding through a momentary loss of input power without
shutting down.
Automatic Restart:
The Vector VII drive can be programmed to automatically restart after a drive fault. The number
of restart attempts can be programmed from 0 to 10 with a factory default setting of zero. Time
between restart attempts is programmable from .5 to 600 seconds with a factory de-fault setting
of 180 seconds.
Jump Frequencies:
Three adjustable set points that lock out continuous operation at frequencies which may pro-
duce mechanical resonance are provided. Bandwidth is selectable from 0 to 20 hertz.
Current Limit
Programmable current limit is from 0% to 180% of drive rated output current.
Acceleration / Deceleration
Accel / Decel settings provide separate adjustments to allow either setting to be adjusted from
0.0 seconds to 6000.0 seconds.
Minimum Frequency Limit / Fault
The minimum frequency limit is set as a percentage of the command / set point frequency and
may be used with PI control. If the drive senses this limit or drops below it a fault occurs and
the drive will shut down.
Wood Group-ESP 2009
19
Bus Regulation
DC Bus regulation is available to reduce the possibility of drive over-voltage trips due to
regenerative conditions. Bus voltage is monitored and an internal regulator adjusts the drives
output frequency to maintain bus voltage at a nominal (100%) level. Undervoltage trip occurs at
380 VDC and overvoltage trip occurs at 800 VDC.
Underload Detection
Enabled or disabled via programming, this feature allows the user to select the output current
level that indicates the load has been lost. A programmable timing delay can also be set.
Maximum time is 10 seconds. Factory default is Disabled and factory default time is 10
seconds.
Motor Overload Protection
Electronic motor overload protection is provided from both a current overload and motor
overheating function. Exceeding either limit results in a trip / fault condition that will de-energize
the drive. Trip time is user selectable.
Fault Memory / Event Log
Faults can be accessed via the event log screen. The event log contains the most current 256
events with each being time stamped with the month, day, year, hour and minute of occurrence.
Any parameter changes will contain previous and current settings for user reference. Data is
stored in a non-volatile memory.
Adjustments
The Operator Control Panel is used for all set-up, operation and adjustment settings. All
adjustments are stored in a nonvolatile memory. No potentiometer adjustments are used.
Communications Interface
Operator Control Panel has multiple user selectable communication port assignments for See
Options list on page 12 for other communication protocols that can be used with the drive.
Hard Start
This function allows the operator to initiate a continuous forward / reverse start of downhole
equipment. Function is designed for assistance in starting equipment that is difficult to start
because of sanded in conditions or similar circumstances. Parameters are user configurable.
Wood Group-ESP 2009
20
OPERATOR CONTROL PANEL
Interface to the Vector VII drive is provided via an Operator Control Panel with integral display.
The display is easily read in bright sunlight and has a backlit LCD. It shows drive operating
conditions, fault indications and programming information. The Operator Control Panel is stand-
ard on all drive ratings, has password protection, and provides a monitoring interface to the
optional SmartGuard
downhole sensor. Data can be retrieved from the drive using a laptop
computer or memory stick via the USB port directly below the Operator Control Panel.
Some of its features are as follows:
Intuitive Menu Select Screen. (See Figure 1)
Comprehensive Run Status Screen. (See Figure 2)
Operator Control Panel displays actual date and time. (See Figure 2)
Drive and well parameters are displayed in plain text. (See Figure 2)
All Monitors Screen gives snapshot of drive and downhole sensor status. (See Figure 3)
Software Embedded Recording Ammeter with 1 or 7 day format. (See Figure 4)
Trending Screen for various surface and downhole parameters. (See Figure 5)
Software Embedded Lock Out Switches. (See Figure 6)
Time Stamped Event Log (256 events). (See Figure 7)
SmartGuard downhole sensor screen. (See Figure 8)
History Logs (35 days of data). (See Figure 9)
Drive status lights showing the drive operating mode (See Figure 10)
Multiple Languages
A representation of the Operator Control Panel is shown below along with an explanation of the
function keys.
Operator Control Panel and USB Port Function Key Explanations
Wood Group-ESP 2009
21
Operator Control Panel Screen Examples:
Figure 1 Figure 2
Figure 3 Figure 4
Figure 5 Figure 6
Wood Group-ESP 2009
22
Operator Control Panel Screen Examples:
Figure 7 Figure 8
History Screen
This screen displays logged performance data using 20 different parameters. They are as
follows.
Figure 9
Drive Outputs SmartGuard Outputs Transformer Outputs
To Motor
Volts DC Bus Volts Intake PSI Vibration Volts
Amps Heat Sink Temp. Discharge PSI Leakage Current Amps
Hertz KW Intake Temp. UpHole DC Volts
Analog 1 PI Control Output Motor Temp.
Analog 2 Status
Digital Input
Wood Group-ESP 2009
23
Operator Control Panel Screen Examples:
Status Indicator Lights
The drive will display drive status information that can be seen from a distance.
Drive status indicators are as follows:
Green = Drive running.
Red = Drive stopped in ready state
Flashing Red = Drive stopped in fault state
Amber = Drive stopped in restart state. Drive
will automatically restart but the time to
restart is greater than 1 minute.
Flashing Amber = Drive stopped in restart or
standby state. Drive will automatically restart
in less than 1 minute. If in standby state, the
drive will restart immediately whenever the
standby switch closes.
Figure 10
Start up of the Vector VII drive can be easily accomplished using basic setup parameters such
as minimum and maximum frequency, acceleration and deceleration times, motor data,
overload and underload limits, and other parameters. An example screen is shown below.
Frequency Setup
Figure 11
Wood Group-ESP 2009
24
Operator Control Panel Screen Examples:
Alarms Setup
The Alarms Setup screen allows a logged on user to set the overload and underload limits as
well as other alarm parameters. See figures 12 and 13 below.
Figure 12 Figure 13
The Vector VII drive is capable of operating as a frequency control, a current control, a pressure
control, or it can be set to follow an Analog Signal from an external source. The following
screens show how to configure the Vector VII drive for Frequency Control or Analog Signal
Follower control.
Operating / Control Mode (Frequency and Analog Follower)
Figure 14 Figure 15
Wood Group-ESP 2009
25
Operator Control Panel Screen Examples:
Operating / Control Mode (Pressure)
An example of the pressure control mode using the internal process PI regulator is shown in
Figures 16 and 17. In this example if the pressure measured at the pump discharge falls below
the set point, the drive will speed up and try to restore the pressure (up to the maximum
frequency defined on the Frequency Setup screen Figure 17). If the pressure exceeds the set
point, the drive will slow to reduce the pressure (down to the minimum frequency defined on the
Frequency Setup screen). The drive will adjust the frequency in the opposite direction if the
intake pressure is used as a reference. Protection is provided for a loss of feedback or
reference signal. Process control can be enabled or disabled with a hardwire input.
Figure 16 Figure 17
Current Control Mode
This allows the drive to operate with a constant current reference point and would primarily be
used for gassy wells.
Figure 18
Wood Group-ESP 2009
26
Operator Control Panel Screen Examples:
Drive I/O Setup
The user can easily determine the state of I/O settings at a glance by using this screen. S1
through S7 are user digital inputs, M1-M2 along with M3-M4 are digital outputs, A1 and A2 are
analog inputs.
Figure 19
Communications (Comm) Setup
A logged on user can define SCADA Modbus address and assign how the communication ports
may be used. Comm port 2 is the default setting for external SCADA system communications.
Figure 20
Wood Group-ESP 2009
27
Operator Control Panel Screen Examples:
Miscellaneous Setup
This screen allows a logged on user to configure various parameters. For example, enable or
disable downhole sensor communications (SmartGuard), set output transformer winding ratio to
allow calculation of downhole motor voltage and current, or external fault settings status
selection.
Figure 21
Maintenance Screen
Logged on user can perform various functions such as checking or updating all drive
parameters, resetting prior parameter settings to factory defaults, upgrading firmware, or
downloading various logs and the internal digital recording ammeter data to a memory stick.
Additionally, if several drives will have the same operating parameters these settings from the
first drive can be downloaded to a memory stick and uploaded to the other drives via the USB
port. This facilitates getting all drives running.
Figure 22
Wood Group-ESP 2009
28
Operator Control Panel Screen Examples:
Last Fault Screen
User / operator can easily view current drive condition and when last fault occurred.
Figure 23
Hard Start Screen
User selectable for situations where pump may be sanded in and hard to start. This allows
submersible equipment to oscillate at pre-determined intervals and ramp up to set point speed
after equipment becomes free.
Figure 24
Wood Group-ESP 2009
29
Surface Pumping Systems (SPS)
Vector VII drives have the capability of communicating serially with the VCS RTU. This allows for
expanded I/O and use of existing VCS RTU SPS software / automation routines for control in surface
pumping applications. Drive Frequency is controlled by the fully programmable internal PID loop of the
RTU. Dedicated I/O points commonly used with SPS applications and other fully programmable I/O
points reside on the RTU. It is recommended that this RTU option be used to control startup sequencing.
Twelve digital I/O (120 VAC standard, 24 VDC optional) and 10 analog I/O (8 analog inputs (4-20 ma
standard, 0-10 VDC optional) and 2 analog outputs (0-10 VDC) are available. These are in addition to the
9 digital I/O and 4 analog I/O on the Vector VII drive (see page 7).
The following flow chart illustrates a typical SPS system start up sequence.
Also shown is the VCS RTU and typical SPS skid system.
Wood Group-ESP 2009
30
INPUT HARMONIC MITIGATION
Excessive AC Line Harmonics can cause problems in the AC power system including the
overheating of power system components such as transformers, circuit breakers, and panel
boards. It can also cause nuisance tripping of circuit breakers, and the inadvertent transfer of
electrical noise to critical loads such as communications systems, computers, and process
control equipment. Drives are a potential source of AC line harmonics and control of those
harmonics reflected back to the power distribution system may be an important consideration in
the selection of a drive. Multi-pulse drives can help you maintain
Vector VII drives may be ordered with 6 Pulse (standard), 12 Pulse, and 18 Pulse input rectifier
assemblies. The 6 pulse input rectifier assembly is generally accepted as the industry standard
for low voltage AC drives. It is very simple, relatively inexpensive, and requires no additional
(phase shifting) transformer for proper operation. When the control of Input AC line harmonics
is important, 12 Pulse and 18 Pulse input rectifier assemblies are often selected. These drive
configurations (12 Pulse and 18 Pulse) are sometimes referred to as multi-pulse drives.
The input rectifier assembly for 12 pulse and 18 pulse drives is more complex than the input
rectifier assembly for a 6 pulse drive in fact, a 12 pulse input rectifier assembly consists of two
6 pulse rectifier bridges operating in parallel and an 18 pulse input rectifier assembly consists of
three 6 pulse rectifier bridges operating in parallel. The added cost of these input rectifier
assemblies is generally not that significant in the overall cost of the drive. The major cost
differential (and it can be quite significant) between a 6 pulse drive and a 12 pulse or 18 pulse
drive is the added cost of the Phase Shift Transformer that is required for multi-pulse operation.
The multi-pulse phase shift transformers have conventional three phase inputs. The output of a
12 pulse phase shift transformer is a six wire connection and the output of an 18 pulse phase
shift transformer is a nine wire connection.
Twelve and Eighteen Pulse drives introduce lower levels of AC line harmonics into the power
system than conventional Six Pulse Drives. Typical measurements for these various different
front end configurations are shown below. These values should be used for estimating purposes
only as measured results can vary based on line impedance, other linear loads on the feeder
transformer, pre-existing harmonics due to other non-linear loads on the supply, and other
factors. In general 12 pulse drives provide substantial reduction in power line harmonics over
6 pulse units and 18 pulse drives provide IEEE-519 compliance.
Category
6-Pulse
Drive
12-Pulse
Drive
18-Pulse
Drive
Current THD 30-35% 6.5-9.5% 4.5-5%
Power Factor .92-.95 .97-.98 .98-.99
DPF .95-.97 .96-.98 .98-.99
K-Factor 3.0-5.0 2.0-3.0 1.0-2.0
Wood Group-ESP 2009
31
Multi-Pulse Examples:
12 Pulse Drive Basic Schematic
18 Pulse Drive Basic Schematic
Wood Group-ESP 2009
32
OUTPUT HARMONIC MITIGATION
Wood Group-ESP developed VSG (Variable Sinewave Generator) technology specifically for
Electric Submersible Equipment. It is a proprietary solution that provides a virtually pure
sinewave output to downhole equipment and elimination of reflected wave phenomenon (motor
spiking). Motor spiking can quickly destroy motor insulation and cause equipment failure. By
virtue of VSG performance characteristics submersible motor heating caused by output
harmonics is dramatically reduced. Typically the industry rule of thumb is that for every 10 C
heat increase over the motor design point insulation life of the equipment decreases by 50%.
Harmonics generate additional heat and mitigation of them can contribute to increased
equipment life and in some cases lower operating expenses. VSG technology is effective with
cable lengths up to 15,000 feet.
Failed motor winding Motor Spiking
Vector VII with VSG Virtually Pure Sinewave Output
Wood Group-ESP 2009
33
Grounding and Bonding
Correct system grounding and equipment bonding is required to ensure proper operation of
equipment during both normal operation and underfault conditions. Grounding and bonding
conductors provide a path to ground for lethal fault currents and voltages. Failure to correctly
ground and bond equipment can lead to equipment damage and personnel injury or death.
Grounding applies to the main service connection to ground. Service transformer wye-point and
enclosures, including the service disconnect switch, must be connected to a common ground
conductor and grounding electrodes (Refer to local electrical authority for approved grounding
electrodes and methods in your area). System ground resistance should not exceed 25 Ohms to
ground and ideally be between 1-5 Ohms to ground. Ground resistance checks should only be
made by qualified electrical inspection agencies.
Bonding applies to all other electrical equipment and raceways. A bonding conductor must be
connected from the main grounding electrodes to all enclosures, junction boxes, buildings,
electrical pipes, and the wellhead.
This equipment provides an internal ground connection for the bonding conductor. This
connector is connected to the internal ground bus of the enclosure.
A typical 3/60/480 VAC ESP installation is shown below.
Wood Group-ESP 2009
34
GENERATOR REQUIREMENTS
Generators are often used as a source of power for oil field applications. When drives are
operated from a generator, specific operational problems can occur unless the overall power
system is properly designed for the application.
Generators almost always have a higher source impedance than that of a typical electrical utility.
Therefore, the non-linear current drawn by a drive tends to distort the generator output voltage
waveform more than it would distort the voltage waveform of the electric utility. This distortion
or flat topping of the generator output voltage waveform can confuse the generators voltage
regulator and lead to a loss of voltage control and wide swings in generator output voltage.
Because of this, the control of AC line harmonics is very important in generator applications.
Whenever possible avoid situations where a generator is required to feed a load that consists
mostly of non-linear loads (such as drives). It is best if the percentage of non-linear load can be
kept to less than 20% of the total load connected to the generator. Often this is not possible.
When a generator is used in a remote location as a power provider for a single drive or a group
of drives, the percentage of non-linear load connected to the generator may approach 100%. In
these situations, the following guidelines should be followed:
1. Use a multi-pulse drive (12 pulse or 18 pulse) to significantly reduce the AC line
harmonics this is usually your best approach.
2. Oversize the alternator component of the generator to lower the relative source
impedance of the generator doubling the size of the alternator will reduce the relative
source impedance by 50%. While this may be helpful in applications where the percent-
age of non-linear load is less than 50% of the total connected load it will probably have
little or no effect in applications where non-linear loads constitute a high percentage of
the connected load.
3. Do not rely on the addition of AC line reactors between the generator and the drive to fix
the problem they simply add line impedance which often makes the problem worse.
4. Be very careful when applying harmonic filters to a generator system passive harmonic
filters generally consist of reactors and capacitors. The reactors add line impedance
which usually does not solve your problem and the capacitors can cause the power
factor to become leading under lightly loaded conditions. In general, generators do not
like a leading power factor load it confuses the generators voltage regulator and leads
to a loss of voltage control and wide swings in generator output voltage.
When Vector VII drives will be operated from a generator source it is best to contact Wood
Group ESP with the following information:
1. Generator information Manufacturer, Model #, Output Voltage, Kw, KVA, and
Impedance.
2. Load Information This information should be in the form of a power one line diagram
with complete information about all connected loads - linear and non-linear. It should
also include information about any line reactors, transformers, harmonic filters, and
power factor correction equipment included on the system.
Wood Group-ESP 2009
35
Generator supplied power systems have the same requirements for grounding and bonding as
utility supplied systems. Grounding electrodes must be installed and a common bonding
conductor must be connected to all equipment and buildings. When the generator system does
not incorporate a wye-point for connection to the system ground, then an isolation transformer is
required between the generator and input to the VSD. This provides protection from floating
voltages, and provides a wye-point for connection to the ground system.
Non compliance with the above guidelines will result in poor performance and / or equipment
failure.
A typical 3/60/480 VAC generator ESP installation is shown below.
Vented Junction Box Detail
See Application Brief 01010 and Drawing 146261 for additional references.
Wood Group-ESP 2009
36
DIMENSIONS & WEIGHTS - VECTOR VII WITHOUT VSG
REFERENCE ONLY
A and B Frames C and D Frames
HEIGHT
(INCHES / MM)
WIDTH
(INCHES / MM)
DEPTH
(INCHES / MM)
FRAME
KVA
H W W1 D D1
WEIGHT
(POUNDS / KG)
150 944 / 429
200 1025 / 465
A
253
82 / 2083
48 /
1220
36 /
915
42 /
1067
36 /
915
1100 / 499
344 1281 / 582
428 1325 / 601
B
561
88 / 2236
57 /
1448
48 /
1220
40 /
1016
36 /
915
1600 / 726
750
850
C
1000
88 / 2236
99 /
2515
72 /
1829
53 /
1347
48 /
1220
4723 / 2143
1200
1400
D
1500
88 / 2236
117 /
2972
90 /
2286
53 /
1347
48 /
1220
4800 / 2178
Note: VSG is required for all ESP applications.
Wood Group-ESP 2009
37
DIMENSIONS & WEIGHTS - VECTOR VII WITH VSG
REFERENCE ONLY
A and B Frames C and D Frames
HEIGHT
(INCHES / MM)
WIDTH
(INCHES / MM)
DEPTH
(INCHES / MM)
FRAME
KVA
H W W1 D D1
WEIGHT
(POUNDS / KG)
150 1320 / 599
200 1400 / 635
A
253
82 / 2083
48 /
1220
36 /
915
42 /
1067
36 /
915
1470 / 667
344 1781 / 808
428 1825 / 828
B
561
103 / 2616
57 /
1448
48 /
1220
40 /
1016
36 /
915
2100 / 953
750
850
C
1000
103 / 2616
99 /
2515
72 /
1829
53 /
1347
48 /
1220
5623 / 2551
1200
1400
D
1500
103 / 2616
117 /
2972
90 /
2286
53 /
1347
48 /
1220
6000 / 2722
Note: VSG is required for all ESP applications.
Wood Group-ESP 2009
38
CORPORATE OFFICE &
MANUFACTURING
WORLDWIDE SALES
& OPERATIONS
OUTSIDE U.S. SALES & SERVICE
5500 S.E. 59th St (73135)
P.O. Box 15070 (73155)
Oklahoma City, OKlahoma, USA
Tel 405-670-1431
Toll free 800-723-3771
Fax 405-670-5463
19416 Park Row, Suite 100
Houston, Texas 77084 USA
Tel 281-492-5100
Fax 281-492-8107
U.S. SALES & SERVICE
GULF COAST
Houston, Texas
Tel: 281-492-5100
Fax: 281-492-8107
Laurel, Mississippi
Tel: 601-649-2030
Toll free: 800-488-9260
Fax: 601-649-8819
MID CONTINENT
Oklahoma, City, Oklahoma*
Tel: 405-671-1431
Toll free: 800-723-3771
Fax: 405-673-5463
Purcell, Oklahoma
Tel: 405-527-1566
Toll free: 800-256-5058
Fax: 405-527-7161
PERMIAN BASIN
Artesia, New Mexico
Tel: 505-746-4614
Fax: 505-746-4519
Hobbs, New Mexico
Tel: 505-392-7999
Fax: 505-392-8190
*Manufacturing Facility in addition to
Sales & Service.
Andrews, Texas
Tel: 432-523-9701
Fax: 432-523-9700
Midland, Texas *
Tel: 432-699-7401
Toll free: 800-749-7402
Fax: 432-699-4159
Snyder, Texas
Tel: 325-573-9325
Fax: 325-573-1616
ROCKY MOUNTAIN / PACIFIC
Denver, Colorado
Tel: 303-350-2111
Toll free: 800-535-0310
Fax: 303-350-2112
Baker, Montana
Toll free: 800-535-0306
Fax: 307-234-4497
Casper, Wyoming *
Tel: 307-234-4495
Toll free: 800-535-0306
Fax: 307-234-4497
CANADA
Brooks, Alberta
Tel: 403-501-5822
Fax: 403-501-5823
Calgary, Alberta
Tel: 403-263-7166
Fax: 403-263-7211
Leduc, Alberta *
Tel: 780-955-2165
Toll free: 888-586-8909
Fax: 780-955-9487
ASIA / PACIFIC
Tanggu, China
Tel: +86-22-6691-4650
Jakarta, Indonesia
Tel: +62-21-8370-2455
Fax: +62-21-831-2456
Singapore
Tel: +65-6396-3626
Fax: +65-6396-5362
Bangkok, Thailand
Tel: +66-2722-2389
Fax: +66-2722-0775
RUSSIA / CIS
Moscow, Russia
Tel: +7-495-937-6641
Fax: +7-495-937-6642
Nizhnevartovsk, Russia *
Tel: +7-3466-416-195
Fax: +7-3466-416-295
EUROPE / AFRICA
Chad, Africa
Tel: +235-626-3279
Fax: +235-41723
Libya, North Africa
Tel: +218-21-582-218-21-484-
2093
Tunisia, Africa
Tel: +216-7169-2281
Fax: +216-7169-2281
Aberdeen, Scotland
Tel: +44-1224-85-1000
Fax: +44-1224-85-1474
LATIN AMERICA
Buenos Aires, Argentina
Tel: +54-4812-2329
Fax: +54-4812-2073
Chubut, Argentina *
Tel: +54-297-446-8254
Fax: +54-297-446-8377
Bogota, Colombia
Tel: +57-1-621-2425
Fax: +57-1-621-2264
Quito, Ecuador
Tel: 593-2-2428-211
Fax: 593-2-2428-213
El Tigre, Venezuela
Tel: +58-283-241-7151
Fax: +58-283-241-8613
Maracaibo, Venezuela *
Tel: +58-261-200-9200
Fax: +58-261-7-361993
MIDDLE EAST
Al Shark, Kuwait
Tel: 965-398-3639-2810
Fax: 965-398-3639-2811
Shati Al Qurum, Oman
Tel: 968-605501
Fax: 968-605784
Dubai, UAE *
Tel: +971-4-883-7595
Fax: +971-4-883-7579
08-15-2009
Woo d Group ESP World-Wide Operations
Saudi Arabia
Oman
UAE
Yemen
Venezuela
Colombia
Argentina
Brazil
Ecuador
Guatemala
Canada
Calgary
Nisku
Brooks
U.S.A.
Casper, WY
Denver, CO
Midland, TX
Hobbs, NM
Purcell, OK
OKC, OK
Moscow
Nizhnevartovsk
Nigeria
Egypt
Algeria
Chad
Libya
Singapore
Indonesia
Australia
Vietnam
Thailand
China
Japan
Business Regions
South America EMA North America Europe, Middle East, Africa
N No or rt th h A Am me er ri ic ca a
C Ce en nt tr ra al l A Am me er ri ic ca a
U UK K
A Af fr ri ic ca a
R Ru us ss si ia a
A As si ia a P Pa ac ci if fi ic c
M Mi id dd dl le e E Ea as st t
S So ou ut th h A Am me er ri ic ca a
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-1
TRANSFORMERS
VARIABLE SPEED DRIVE TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
67 480
480-960 DELTA
831-1663 WYE
47 x 35 x 41 119 x 89 x 104 2390 1084 136829
100 480
750-1258 DELTA
1300-2160 WYE
54 x 37 x 41 137 x 90 x 104 2530 1148 136828
130 480
750 1497 DELTA
1299 2600 WYE
56 x 46 x 44
142 x 117 x
112
2850 1293 136827
130 480
750 1550 DELTA
1299 2685 WYE
50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390
150 480
800-1559 DELTA
1386 - 2700 WYE
68 x 46 x 44
173 x 117 x
112
3740 1696 136683
200 480
1100 2200 DELTA
1905 3811 WYE
53 X 43 X 51.5
135 x 109.x
131
3530 1601 1057017
210 480
1100 2200 DELTA
1905 3810 WYE
60 x 48 x 50
152 x 122 x
127
3850
1746
136826
250 415
950-1900 DELTA
1650-3300 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 127729
250 480
1100-2200 DELTA
1905-3810 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 136682
260 480
1100 2200 DELTA
1905 3811 WYE
60 X 52 X 48
152 x 132 x
122
4220 1914 136825
350 480
1100 2200 DELTA
1905 3811 WYE
74 x 54 x 50
188 x 137 x
127
6540 2967 136824
355 480
1100 2200 DELTA
1905 3811 WYE
57.5 X 45 X
53.5
146 x 114 x
136
5350 2427 1054386
400 415
950-1900 DELTA
1650-3300 WYE
61 x 61 x 54
155 x 155 x
137
6675 3028 127961
400 480
1109-2166 DELTA
1921-3732 WYE
75 x 61 x 54
191 x 155 x
137
6675 3028 136823
400 480
1100 2200 DELTA
1905 3811 WYE
70 X 42 X 62
178 x 107 x
158
4500 2041 1057416
450 480
1100-2200 DELTA
1905-3810 WYE
78 x 46 x 58
198 x 117 x
147
8175 3708 136681
520 480
1100 2200 DELTA
1905 3811 WYE
78 x 65 x 54
198 x 165 x
137
8300 3765 136822
750 480
1300-2601 DELTA
2252-4505 WYE
82 x 67 x 60
208 x 170 x
152
9326 4230 136680
750 480
1320-2640 DELTA
2286-4572 WYE
81 x 67 x 62
206 x 170 x
157
9800 4445 136821
850 480
1400-2800 DELTA
2424-4850 WYE
82 x 68 x 62
208 x 173 x
157
11200 5080 136820
1000 480
1400-2800 DELTA
2424-4850 WYE
86 x 67 x 64
218 x 170 x
163
11500 5216 136819
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS
SPECIALTY TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
125 6000
1100-2200 DELTA
1905-3810 WYE
56 x 45 x 46
142 x 114 x
117
3275 1486 136253
150 13800
800-1559 DELTA
1386-2700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136615
150 34500
800-1559 DELTA
13862700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136614
250 13800
1100-2200 DELTA
2200-3810 WYE
70 x 52 x 48
178 x 132 x
122
4431 2010 136675
250 34500
1100-2200 DELTA
2200-3810 WYE
78 x 52 x 50
198 x 132 x
127
4642 2106 136674
450 13800
1100-2200 DELTA
2200-3810 WYE
88 x 65 x 54
224 x 165 x
137
8450 3833 136677
450 34500
1100-2200 DELTA
2200-3810 WYE
96 x 65 x 54
244 x 165 x
137
8650 3924 136676
500 13800
1100-2200 DELTA
1905-3811 WYE
76 x 80 x 55
193 x 203 x
140
6502 2949 136198
750 13800
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
9792 4442 136679
750 34500
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
10307 4675 136678
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-3
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5 480/831 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex 37.5 2400/4160 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex
37.5 7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex 37.5 12470 *
831 3325 Y
45 x 23 x
26
114 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5 14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
19920/34500 grd
Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex 50 480/831 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex 50 2400/4160 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 12470 *
831 3325 Y
49 x 23 x
26
124 x 58 x
66
750 340
480 1920
1731- 2510 ex
50 14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
19920/34500 grd
Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
480 1920
1731- 2510 ex
75 480/831 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731 2510 ex
75 2400/4160 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 12470 *
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex
75
19920/34500
grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex 100 480/831 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 2400/4160 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 12470 *
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
19920/34500
grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-5
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167 2400/4160 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 12470
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex 167 19920/34500 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
200 7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 12470
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex
200 14400/24940 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 19920/34500 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009
TRANSFORMERS
SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5
2400/4160 Y
7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex
37.5
7200/12470 Y
14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
14400/24940 Y
19920/34500 grd Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
50
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex 75
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex 75
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex
100
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-7
TRANSFORMERS
SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
167
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
200
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1750 793
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-1
TRANSFORMERS
VARIABLE SPEED DRIVE TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
67 480
480-960 DELTA
831-1663 WYE
47 x 35 x 41 119 x 89 x 104 2390 1084 136829
100 480
750-1258 DELTA
1300-2160 WYE
54 x 37 x 41 137 x 90 x 104 2530 1148 136828
130 480
750 1497 DELTA
1299 2600 WYE
56 x 46 x 44
142 x 117 x
112
2850 1293 136827
130 480
750 1550 DELTA
1299 2685 WYE
50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390
150 480
800-1559 DELTA
1386 - 2700 WYE
68 x 46 x 44
173 x 117 x
112
3740 1696 136683
200 480
1100 2200 DELTA
1905 3811 WYE
53 X 43 X 51.5
135 x 109.x
131
3530 1601 1057017
210 480
1100 2200 DELTA
1905 3810 WYE
60 x 48 x 50
152 x 122 x
127
3850
1746
136826
250 415
950-1900 DELTA
1650-3300 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 127729
250 480
1100-2200 DELTA
1905-3810 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 136682
260 480
1100 2200 DELTA
1905 3811 WYE
60 X 52 X 48
152 x 132 x
122
4220 1914 136825
350 480
1100 2200 DELTA
1905 3811 WYE
74 x 54 x 50
188 x 137 x
127
6540 2967 136824
355 480
1100 2200 DELTA
1905 3811 WYE
57.5 X 45 X
53.5
146 x 114 x
136
5350 2427 1054386
400 415
950-1900 DELTA
1650-3300 WYE
61 x 61 x 54
155 x 155 x
137
6675 3028 127961
400 480
1109-2166 DELTA
1921-3732 WYE
75 x 61 x 54
191 x 155 x
137
6675 3028 136823
400 480
1100 2200 DELTA
1905 3811 WYE
70 X 42 X 62
178 x 107 x
158
4500 2041 1057416
450 480
1100-2200 DELTA
1905-3810 WYE
78 x 46 x 58
198 x 117 x
147
8175 3708 136681
520 480
1100 2200 DELTA
1905 3811 WYE
78 x 65 x 54
198 x 165 x
137
8300 3765 136822
750 480
1300-2601 DELTA
2252-4505 WYE
82 x 67 x 60
208 x 170 x
152
9326 4230 136680
750 480
1320-2640 DELTA
2286-4572 WYE
81 x 67 x 62
206 x 170 x
157
9800 4445 136821
850 480
1400-2800 DELTA
2424-4850 WYE
82 x 68 x 62
208 x 173 x
157
11200 5080 136820
1000 480
1400-2800 DELTA
2424-4850 WYE
86 x 67 x 64
218 x 170 x
163
11500 5216 136819
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS
SPECIALTY TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
125 6000
1100-2200 DELTA
1905-3810 WYE
56 x 45 x 46
142 x 114 x
117
3275 1486 136253
150 13800
800-1559 DELTA
1386-2700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136615
150 34500
800-1559 DELTA
13862700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136614
250 13800
1100-2200 DELTA
2200-3810 WYE
70 x 52 x 48
178 x 132 x
122
4431 2010 136675
250 34500
1100-2200 DELTA
2200-3810 WYE
78 x 52 x 50
198 x 132 x
127
4642 2106 136674
450 13800
1100-2200 DELTA
2200-3810 WYE
88 x 65 x 54
224 x 165 x
137
8450 3833 136677
450 34500
1100-2200 DELTA
2200-3810 WYE
96 x 65 x 54
244 x 165 x
137
8650 3924 136676
500 13800
1100-2200 DELTA
1905-3811 WYE
76 x 80 x 55
193 x 203 x
140
6502 2949 136198
750 13800
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
9792 4442 136679
750 34500
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
10307 4675 136678
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-3
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5 480/831 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex 37.5 2400/4160 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex
37.5 7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex 37.5 12470 *
831 3325 Y
45 x 23 x
26
114 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5 14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
19920/34500 grd
Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex 50 480/831 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex 50 2400/4160 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 12470 *
831 3325 Y
49 x 23 x
26
124 x 58 x
66
750 340
480 1920
1731- 2510 ex
50 14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
19920/34500 grd
Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
480 1920
1731- 2510 ex
75 480/831 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731 2510 ex
75 2400/4160 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 12470 *
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex
75
19920/34500
grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex 100 480/831 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 2400/4160 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 12470 *
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
19920/34500
grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-5
TRANSFORMERS
SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167 2400/4160 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 12470
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex 167 19920/34500 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
200 7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 12470
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex
200 14400/24940 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 19920/34500 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009
TRANSFORMERS
SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5
2400/4160 Y
7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex
37.5
7200/12470 Y
14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
14400/24940 Y
19920/34500 grd Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
50
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex 75
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex 75
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex
100
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-7
TRANSFORMERS
SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
167
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
200
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1750 793
*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group
5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1
11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1
18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1
25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1
32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1
38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1
45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1
52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1
59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1
65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1
73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1
79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1
86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1
92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1
100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1
104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1
111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1
118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1
130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1
138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1
146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1
152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1
158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1
165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1
172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1
178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1
184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group
192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1
200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1
205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1
212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1
219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1
225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1
231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1
237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1
244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1
251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1
258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1
264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1
270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE1500) E0050
Motor
Group
7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0050 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0050 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1
37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1
45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1
52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83
E0050 CMP 83 STG
5174 17.5 22 4 1 1 1 1 1
90
E0050 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98
E0050 CMP 98 STG
5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE2700) E0080
Motor
Group
7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0080 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0080 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30
E0080 CMP 30 STG
3592 7.0 14 2 1 1 1 1 1
37
E0080 CMP 37 STG
3653 8.5 14 2 1 1 1 1 1
45
E0080 CMP 45 STG
4185 10.0 18 3 1 1 1 1 1
52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1
90
E0080 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE5500) E0170
Motor
Group
5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1
11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1
17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1
23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1
29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1
35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1
41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1
47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1
53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1
59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1
65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1
71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1
77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1
83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1
89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1
94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1
100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1
106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1
112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1
118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1
130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1
136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1
142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1
148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1
154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1
160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1
166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1
172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1
178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1
183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1
189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1
195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1
201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1
THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR
Heads & Bases
Discharge
Assembly
3 Coated Steel
(TE7000) E0220
Motor
Group
154
160
(2) 77 STG HSS
(1) 83 STG + (1) 77 STG
UHSS
9598 41.0 38 8
10228 42.5 38 12
10 1
11 1
1 1 1 1
1 1 1 1
166
172
(2) 83 STG UHSS
(1) 89 STG + (1) 83 STG
UHSS
10293 44.0 38 12
10358 45.5 38 12
11 1
11 1
1 1 1 1
1 1 1 1
178
183
189
(2) 89 STG UHSS
(1) 65 STG + (2) 59 STG
UHSS
(2) 65 STG + (1) 59 STG
UHSS
10988 47.0 38 16
11104 49.5 38 16
11734 51.0 38 20
12 1
12 1
13 1
1 1 1 1
1 1 1 1
1 1 1 1
195
201
207
(3) 65 STG UHSS
(1) 71 STG + (2) 65 STG
UHSS
(2) 71 STG + (1) 65 STG
UHSS
11799 52.5 38 20
12429 54.0 38 24
12244 55.5 38 24
13 1
14 1
14 1
1 1 1 1
1 1 1 1
1 1 1 1
213
219
225
(3) 71 STG UHSS
(1) 77 STG + (2) 71 STG
UHSS
(2) 77 STG + (1) 71 STG
UHSS
12309 57.0 38 24
13040 58.5 38 28
13106 60.0 38 28
14 1
15 1
15 1
1 1 1 1
1 1 1 1
1 1 1 1
231
237
243
(3) 77 STG UHSS
(1) 83 STG + (2) 77 STG
UHSS
(2) 83 STG + (1) 77 STG
UHSS
13172 61.5 38 28
13702 63.0 38 32
13767 64.5 38 32
15 1
16 1
16 1
1 1 1 1
1 1 1 1
1 1 1 1
249
255
261
(3) 83 STG UHSS
(1) 89 STG + (2) 83 STG
UHSS
(2) 89 STG + (1) 83 STG
UHSS
14397 66.0 38 36
14462 67.5 38 36
14527 69.0 38 36
17 1
17 1
17 1
1 1 1 1
1 1 1 1
1 1 1 1
267
272
(3) 89 STG UHSS
(2) 71 STG + (2) 65 STG
UHSS
15257 70.5 38 40
15372 73.0 38 40
18 1
18 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group
2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1
9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1
12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1
15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1
19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1
22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1
25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1
29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1
32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1
35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1
39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1
42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1
45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1
48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group
87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1
90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1
93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1
96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1
99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1
102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1
105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1
109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1
113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1
117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1
120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
1 1 1 1
www.woodgroup-esp.com
Page-9
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ9000) J0270
Motor
Group
2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1
9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1
12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1
15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1
19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1
22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1
25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1
29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1
32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1
35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1
39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1
42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1
45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1
48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1
87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ12000) J0360
Motor
Group
2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1
5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1
8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1
11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1
14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1
17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1
20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1
23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1
26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1
29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1
32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1
35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1
38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1
41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1
44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1
46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1
49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1
52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1
55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1
58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1
64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1
70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
4 Coated Steel
(TM19000) M0560
Motor
Group
8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1
21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1
22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1
23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1
24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1
25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1
26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1
27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1
28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1
29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1
30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1
31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1
THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TM24000) M0700
Motor
Group
8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20
21
22
23
24
25
26
27
28
29
30
31
M0700 CMP A-CUT 20 STG
M0700 CMP A-CUT 21 STG
HSS
M0700 CMP A-CUT 22 STG
HSS
M0700 CMP A-CUT 23 STG
HSS
M0700 CMP A-CUT 24 STG
HSS
M0700 CMP A-CUT 25 STG
HSS
M0700 CMP A-CUT 26 STG
HSS
M0700 CMP A-CUT 27 STG
HSS
M0700 CMP A-CUT 28 STG
HSS
M0700 CMP A-CUT 29 STG
HSS
M0700 CMP A-CUT 30 STG
HSS
M0700 CMP A-CUT 31 STG
HSS
5464 13.6 18
6199 14.2 22
6266 14.8 22
6331 15.4 22
6398 16.0 22
6468 16.6 22
6536 17.2 22
7168 17.8 26
7232 18.4 26
7302 19.0 26
7369 19.6 26
7437 20.2 26
3 1
4 1
4 1
4 1
4 1
4 1
4 1
5 1
5 1
5 1
5 1
5 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.
N 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TN35000) N1150
Motor
Group
1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1
2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1
3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1
4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1
5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1
6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1
7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1
8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1
9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1
10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1
11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1
THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group
5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1
11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1
18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1
25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1
32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1
38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1
45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1
52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1
59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1
65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1
73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1
79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1
86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1
92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1
100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1
104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1
111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1
118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1
130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1
138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1
146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1
152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1
158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1
165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1
172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1
178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1
184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group
192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1
200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1
205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1
212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1
219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1
225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1
231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1
237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1
244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1
251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1
258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1
264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1
270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE1500) E0050
Motor
Group
7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0050 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0050 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1
37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1
45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1
52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83
E0050 CMP 83 STG
5174 17.5 22 4 1 1 1 1 1
90
E0050 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98
E0050 CMP 98 STG
5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE2700) E0080
Motor
Group
7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0080 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0080 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30
E0080 CMP 30 STG
3592 7.0 14 2 1 1 1 1 1
37
E0080 CMP 37 STG
3653 8.5 14 2 1 1 1 1 1
45
E0080 CMP 45 STG
4185 10.0 18 3 1 1 1 1 1
52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1
90
E0080 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE5500) E0170
Motor
Group
5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1
11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1
17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1
23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1
29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1
35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1
41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1
47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1
53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1
59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1
65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1
71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1
77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1
83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1
89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1
94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1
100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1
106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1
112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1
118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1
130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1
136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1
142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1
148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1
154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1
160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1
166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1
172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1
178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1
183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1
189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1
195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1
201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1
THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000
ESP Pump Description
Pumps have SS & AR
Heads & Bases
Discharge
Assembly
3 Coated Steel
(TE7000) E0220
Motor
Group
154
160
(2) 77 STG HSS
(1) 83 STG + (1) 77 STG
UHSS
9598 41.0 38 8
10228 42.5 38 12
10 1
11 1
1 1 1 1
1 1 1 1
166
172
(2) 83 STG UHSS
(1) 89 STG + (1) 83 STG
UHSS
10293 44.0 38 12
10358 45.5 38 12
11 1
11 1
1 1 1 1
1 1 1 1
178
183
189
(2) 89 STG UHSS
(1) 65 STG + (2) 59 STG
UHSS
(2) 65 STG + (1) 59 STG
UHSS
10988 47.0 38 16
11104 49.5 38 16
11734 51.0 38 20
12 1
12 1
13 1
1 1 1 1
1 1 1 1
1 1 1 1
195
201
207
(3) 65 STG UHSS
(1) 71 STG + (2) 65 STG
UHSS
(2) 71 STG + (1) 65 STG
UHSS
11799 52.5 38 20
12429 54.0 38 24
12244 55.5 38 24
13 1
14 1
14 1
1 1 1 1
1 1 1 1
1 1 1 1
213
219
225
(3) 71 STG UHSS
(1) 77 STG + (2) 71 STG
UHSS
(2) 77 STG + (1) 71 STG
UHSS
12309 57.0 38 24
13040 58.5 38 28
13106 60.0 38 28
14 1
15 1
15 1
1 1 1 1
1 1 1 1
1 1 1 1
231
237
243
(3) 77 STG UHSS
(1) 83 STG + (2) 77 STG
UHSS
(2) 83 STG + (1) 77 STG
UHSS
13172 61.5 38 28
13702 63.0 38 32
13767 64.5 38 32
15 1
16 1
16 1
1 1 1 1
1 1 1 1
1 1 1 1
249
255
261
(3) 83 STG UHSS
(1) 89 STG + (2) 83 STG
UHSS
(2) 89 STG + (1) 83 STG
UHSS
14397 66.0 38 36
14462 67.5 38 36
14527 69.0 38 36
17 1
17 1
17 1
1 1 1 1
1 1 1 1
1 1 1 1
267
272
(3) 89 STG UHSS
(2) 71 STG + (2) 65 STG
UHSS
15257 70.5 38 40
15372 73.0 38 40
18 1
18 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group
2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1
9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1
12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1
15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1
19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1
22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1
25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1
29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1
32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1
35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1
39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1
42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1
45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1
48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group
87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1
90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1
93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1
96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1
99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1
102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1
105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1
109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1
113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1
117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1
120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
1 1 1 1
www.woodgroup-esp.com
Page-9
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ9000) J0270
Motor
Group
2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1
9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1
12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1
15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1
19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1
22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1
25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1
29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1
32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1
35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1
39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1
42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1
45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1
48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1
87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ12000) J0360
Motor
Group
2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1
5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1
8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1
11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1
14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1
17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1
20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1
23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1
26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1
29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1
32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1
35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1
38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1
41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1
44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1
46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1
49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1
52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1
55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1
58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1
64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1
70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
4 Coated Steel
(TM19000) M0560
Motor
Group
8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1
21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1
22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1
23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1
24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1
25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1
26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1
27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1
28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1
29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1
30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1
31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1
THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TM24000) M0700
Motor
Group
8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20
21
22
23
24
25
26
27
28
29
30
31
M0700 CMP A-CUT 20 STG
M0700 CMP A-CUT 21 STG
HSS
M0700 CMP A-CUT 22 STG
HSS
M0700 CMP A-CUT 23 STG
HSS
M0700 CMP A-CUT 24 STG
HSS
M0700 CMP A-CUT 25 STG
HSS
M0700 CMP A-CUT 26 STG
HSS
M0700 CMP A-CUT 27 STG
HSS
M0700 CMP A-CUT 28 STG
HSS
M0700 CMP A-CUT 29 STG
HSS
M0700 CMP A-CUT 30 STG
HSS
M0700 CMP A-CUT 31 STG
HSS
5464 13.6 18
6199 14.2 22
6266 14.8 22
6331 15.4 22
6398 16.0 22
6468 16.6 22
6536 17.2 22
7168 17.8 26
7232 18.4 26
7302 19.0 26
7369 19.6 26
7437 20.2 26
3 1
4 1
4 1
4 1
4 1
4 1
4 1
5 1
5 1
5 1
5 1
5 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.
N 950 SERIES SP1000
ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TN35000) N1150
Motor
Group
1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1
2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1
3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1
4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1
5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1
6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1
7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1
8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1
9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1
10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1
11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1
THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
WELLHEAD EQUIPMENT
WELLHEADS HHS - COMPLETE UNIT
PART NUMBER
CSG O.D.
TBG
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741261
2 7/8 741263
2 3/8
2 7/8 741234
3 1/2 741241 741243
2 3/8
2 7/8
3 1/2
4 1/2
2 3/8
2 7/8
3 1/2 741259
4 1/2 741482 741260
5 1/2 741251
2 7/8
4 1/2 741255
5 1/2 741253
7 741254
6 741262
7
6 5/8 741285
#2 RND #2 FLAT #4 RND
741205 741202
741211 741208
741217 741214
741223 741220
741229 741226
741233 741237 741232
741240 741242 741239
741244 741245
721247
741248
741257
741249 741529
741250
741455
741252
741283
#4 FLAT #6 RND #6 FLAT #8 RND
741204 741201 741203 741200
741210 741207 741209 741206
741216 741213 741215 741212
741222 741219 741221 741218
741228 741225 741227 741224
741236 741231 741235 741230
741284 741238
741256 741246
741458
741798
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 1
Wood Group ESP, Inc.
WELLHEAD EQUIPMENT
WELLHEADS HHS - TOP PLATE
PART NUMBER
CSG O.D.
TBG
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8
PLATE
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741377
2 7/8 741410
2 3/8
2 7/8 741410
3 1/2 741410
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741434
4 1/2 741437
4 1/2 741419
6 741467
6 5/8 741467
7
#2 RND #2 FLAT #4 RND
741377 741368
741395 741386
741377 741368
741395 741386
741377 741368
741422 741395 741386
741410
741440
741444
741453
#4 FLAT #6 RND #6 FLAT #8 RND
741374 741365 741371 741362
741392 741383 741389 741380
741374 741365 741371 741362
741392 741383 741389 741380
741374 741365 741371 741362
741392 741383 741389 741380
741472
741416
741474
WELLHEADS HHS - BOTTOM
PART NUMBER
CSG O.D.
TBG
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741375
2 7/8 741408
2 3/8
2 7/8 741423 741408
3 1/2 741405 741408
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741448 741432
4 1/2 741435
4 1/2 741417
6 741465
6 5/8 741451
7
#2 RND #2 FLAT #4 RND
741375 741366
741393 741384
741375 741366
741393 741384
741375 741366
741420 741393 741384
741402 741408 741399
741426
741438
741442 741449
741465
#4 FLAT #6 RND #6 FLAT #8 RND
741372 741363 741369 741360
741390 741381 741387 741378
741372 741363 741369 741360
741390 741381 741387 741378
741372 741363 741369 741360
741390 741381 741387 741378
741470 741396
741414
741459
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
WELLHEAD EQUIPMENT
WELLHEADS HHS - PACKOFF RUBBERS
PART NUMBER
CSG O.D.
TBG
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8
GLAND
EUE #1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741359
2 7/8 741412
2 3/8
2 7/8 741424 741412
3 1/2 741266 741412
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741433
4 1/2 741436
4 1/2 741418
7 741800
6 741466
6 5/8 741452
7
#2 RND #2 FLAT #4 RND
741376 741367
741394 741385
741376 741367
741394 741385
741376 741367
741421 741394 741385
741409
741439
741443
741466
#4 FLAT #6 RND #6 FLAT #8 RND
741373 741364 741361
741391 741382 741388 741379
741373 741364 741361
741391 741382 741388 741379
741373 741364 741361
741391 741382 741388 741379
741471
741415
741473
WELLHEAD HHS - BODY - SLIPS - PACKING
CSG
O.D
BODY
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8
PART
NUMBER 2 3/8 2 7/8
741350 741300 741301
741351 741300 741301
741352 741300 741301
741353 741430
741354 741304 741441
741355
741469
SLIPS PART NUMBER
3 1/2 4 1/2 5 1/2 6
741302 741429
741308 741303
741305
PACKING
GLAND
6 5/8 7 PART
NUMBER
741340
741340
741340
741342
741341
741341
741450 741464 741468
HHS SPECIFICATIONS
TYPE
HHS
HHS
HHS
HHS
HHS
HHS
HHS
HHS
HHS
CASING SIZE TUBING SIZE
O.D. (Inches) O.D. (Inches)
4 1/2, 5 1/2, 7 2 3/8
4 1/2, 5 1/2, 7 2 7/8
7 3 1/2
8 5/8 2 3/8, 3 1/2
8 5/8 4 1/2
8 5/8 5 1/2
9 5/8, 10 3/4 2 3/8, 3 1/2
9 5/8, 10 3/4 4 1/2
9 5/8, 10 3/4 5 1/2
RECOMMENDED
MAX LOAD
Lbs Kgs
80,000 36,000
80,000 36,000
80,000 36,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
MAXIMUM
SETTING DEPTH WEIGHT
(Safety Factor = 2.0)
Ft. M. Lbs Kgs
10,000 3,048 144 66
7,100 2,165 144 66
4,900 1,495 148 68
4,900 1,495 186 85
3,200 975 186 85
2,600 790 186 85
4,900 1,495 226 103
3,200 975 226 103
2,600 790 226 103
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 3
Wood Group ESP, Inc.
Bolt
On
Head
Couplings between Units
Couplings are shipped at the top of each unit except for the coupling adapter at the bottom of the seal and the
pump to intake (or GS) that must be ordered separately. All coupling splines are SAE 6 tooth, unless noted as
INV (Involute).
Coupling TA/TR3 TD/TR387/TR4 TG/TR5 TE/TR5/E56 TH/TR5 TJ/TR7 TM/TR7 TN
919415
Pump
Pump
Intake or
Gas
Separator
Seal
Pump
To
Pump
Pump
To
Intake
or GS
(3/8 )
914341
(5/8)
934182
(11/16)
Cprsn
120555
(5/8)
120556
(11/16)
919605
(3/8 to
11/16)
912022
(5/8 to
11/16)
934182
(11/16)
1008556 (1/2)
926477 (5/8)
934182 (11/16)
934026 (7/8)
Cprsn
120554 (1/2)
120555 (5/8)
120556 (11/16)
120557 (7/8)
934281
5/8- 7/8
934232
(11/16 to 7/8)
934026
(7/8)
934026 (7/8)
1011709 (1) 120557
(7/8)
123270
Cprsn (1)
952572
120557 (7/8) (1-3/16)
123270 (1)
949388
949388 (7/8 to
(7/8 to 1-3/16)
1-3/16)
123247
949651 (1-3/16)
(1 to
1-3/16) 949651
1- 1 3/16
123270 (1)
952572 1032770
952572 (1-3/16) (1-1/2)
(1-3/16)
952572
(1 3/16)
952572 1032770
949651 (1-3/16) (1-1/2)
(1 to
1-3/16)
Intake or GS
To Seal
912071
(11/16 to 934026 (7/8)
3/4)
960765
944512 123247
(1-3/16 to
(1 3/16) (1-3/16)
1-1/2)
Seal
to
Seal Seal
926956 Unit Adptr & Cplg
(3/4) 740211 (7/8)
943829 (1-3/16)
960245
151409 (1-3/16 HL)
(1-1/2)
151407 (1-3/16 pre-shimmed)
Coupling
Adapter
1046754
(3/4 to
1-3/16)
960641
1002575
945592 (1-3/16 to 2) (1-1/2 to
(7/8 to 1-1/2)
2-1/4)
Motor
Type 62 & 92
Seal 1000124
To 1042043 (1-1/8 to 1- 1/2)
Motor (7/8 to
(Sgl or UT) 1-3/16) Type 92 HTI
or BOH 120697
(1-1/8 to 1-1/2) Inv
Type 62 SGL: 947986
(2 to 1-3/16)
960294
Type 62 & 92 UT: 948042 (2-1/4 to
(2 to 1- 3/8) (1- 1/2)
Type 92HTI: 121437
(2 to 1-3/8) Inv
Type 62: 933523
(1)
Motor
Motor
Base
or
Sensor
Motor
To
Motor 914259
(CT or LT) (11/16)
Type 92: 110716 Type 62: 944165 (1-3/16)
(1-1/8)
Type 92: 1017623 (1-3/8)
Type 92 HTI
120696 Type 92 HTI to 92 Std: 141712
(1-1/8) Inv (1-3/8 inv to 1-3/8)
Type 62 to 92 Type 92HTI: 121784 (1-3/8) Inv
120862
(1 to 1-1/8) Type 92-62: 141710
(1-3/16 to 1-3/8)
Type 92 - 62
120787
(1-1/8 to 1)
961961
(1-1/2)
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
CHECK VALVES AND BLEEDER VALVES
DESCRIPTION
CHECK VALVES -up to 2200 psi
CHECK VALVE 2 3/8 - 8rd 2200
CHECK VALVE 2 3/8 - 8rd 2200 SST
CHECK VALVE 2 7/8 - 8rd 2200
CHECK VALVE 2 7/8 - 8rd 2200 SST
CHECK VALVE 3 1/2 - 8rd 2200
CHECK VALVE 3 1/2 - 8rd 2200 SST
CHECK VALVES -up to 5000 psi
CHECK VALVE 2 3/8 - 8rd 5000
CHECK VALVE 2 3/8 - 8rd 5000 SST
CHECK VALVE 2 7/8 - 8rd 5000
CHECK VALVE 2 7/8 - 8rd 5000 SST
CHECK VALVE 3 1/2 - 8rd 5000
CHECK VALVE 3 1/2 - 8rd 5000 SST
BLEEDER VALVES
BLEEDER VALVE 2 3/8 - 8rd
BLEEDER VALVE 2 7/8 - 8rd
BLEEDER VALVE 3 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 4 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 5 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 7 - 8rd
WEIGHT PART
Lbs. Kgs. NUMBER
6 2.72 913939
6 2.72 120169
10 4.54 925206
10 4.54 120168
16 7.26 926386
16 7.26 143565
9 4.08 145935
9 4.08 145936
15 6.80 143316
15 6.80 143317
24 10.89 145937
24 10.89 143327
6 2.72 912501
10 4.54 925339
16 7.26 926394
127400
127402
127403
BREAK OFF PLUGS
BRASS 2, 2 3/8, 2 7/8, and 3 1/2 0.30 0.14 911966
MONEL 2, 2 3/8, 2 7/8, and 3 1/2 0.30 0.14 925354
REDUCING NIPPLES
2 3/8 OD 8rd x 2 7/8 OD 8rd 2.5 1.13 917567
2 3/8 OD 8rd x 3 1/2 OD 8rd 7.5 3.40 917575
2 7/8 OD 8rd x 3 1/2 OD 8rd 7.5 3.40 917583
SHIPPING BOXES w/o Hinges
EQUIPMENT DIA
INSIDE
Type 300-700 Series 7
Type 300-900 Series 12
LENGTH WEIGHT PART
Feet Meters Lbs. Kgs NUMBER
6 1.8 146 66.2 741111
7.5 2.3 188 85.3 741121
12.5 3.8 351 159.2 741112
15.5 4.7 435 197.3 741113
18.5 5.6 500 226.8 741114
23 7.0 621 281.7 741115
26 7.9 750 340.2 741116
28.5 8.7 810 367.4 741117
32 9.8 926 420.0 741118
36 11.0 1042 472.7 741119
7.5 2.3 310 140.6 741124
12 3.7 495 224.5 741120
15 4.6 619 280.8 741127
23 7.0 949 430.5 741125
26 7.9 1073 486.7 741126
34 10.4 1403 636.4 741128
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 5
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
MONEL HARDWARE KITS
SERIES TR3 TR4 TR5 TR6 TR7 TR8
PUMP 1054519 1054519 1054691 1054766 1054774
INTAKE 1054519 1054519 1054691 1054766 1054774
GAS SEPARATOR 1054519 1054519 1054691
SEAL 1054527 1054584 1054709 1054782 1054782
MOTOR (SINGLE) 1054535 1054592 1054717 1054790
MOTOR (UT) 1054543 1054600 1054725 1054808
MOTOR (CT) 1054550 1054618 1054733 1059162
MOTOR (LT) 1054568 1054626 1054741 1054816
SENSOR- PRESS & TEMP 1054576 1054683 1054758 1054824
SENSOR - PRESSURE ONLY 1055078 1055086 1055094 1055102
BOLT-ON-BASE 1055078 1055086 1055094 1055102
Notes:
1. Monel bolts and washers are supplied as standard with all downhole equipment. Above monel
hardware kits are available to replace or upgrade equipment and includes all bolts, washers, plugs
and drain and fill components. These components may also be purchased as individual parts from
any Wood Group ESP, Inc. facility. Contact your sales or service representative for individual part
prices.
2. Monel bolts and washers are recommended for use with all components having a corrosion
resistant coating.
3. Screws and lock washers are for the top end connection of the listed equipment.
4. O-rings are not provided in the kits.
MONEL HARDWARE KITS
DESCRIPTION PART NUMBER
FLAME SPRAY COATING APP-83
METAL FLAME SPRAY COATING - TOUCH-UP KIT 922872
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
MOTOR OIL
DESCRIPTION
ROCON #2 MEDIUM - 5 GALLON CAN
ROCON #3 (SYNTHETIC) - 5 GALLON CAN
ROCON #220 (SYNTHETIC - HI-TEMP) - 55 GALLON CAN
WEIGHT PART
Lbs. Kgs. NUMBER
25 11.3 985978
37 16.8 2643022
462 209.6 127295
OIL FILLING COMPONENTS
OIL CAN COMPLETE WITH PUMP, HOSE. ETC 16 7.3 1059270
PUMP 1059288
PUMP HOSE 1059296
SWEDGELOK - FEMALE 1059304
PRESSURE GAGE 1059320
ALEMITE ADAPTER 1059338
CAN, 5 GALLON WITH SEAL 0.60 0.27 1059714
PIPE, 19 X .500 BLACK 127063
PIPE ELBOW 1/2 127064
PIPE NIPPLE 1/2 X 1 1/2 127065
PIPE REDUCER 127066
PIPE TEE 127067
SCREW, HEX HEAD 5/16 X 3/4 127068
PLATE, STEEL 127069
PUMP HANDLE 127070
INSTALLATION CLAMPS
TR3 MOTOR SHOULDER CLAMP 24 10.89 T111
TA PUMP SHOULDER CLAMP 24 10.89 T110
TA PUMP FRICTION CLAMP 24 10.89 T2345
TR3 SEAL FRICTION CLAMP 24 10.89 T2346
TR387 PUMP FRICTION CLAMP 24 10.89 T2166
TR4 MOTOR SHOULDER CLAMP 24 10.89 T478
TD PUMP SHOULDER CLAMP 24 10.89 T479
TD PUMP FRICTION CLAMP 24 10.89 T328
TR5 MOTOR CLAMP 24 10.89 T480
TG PUMP FRICTION CLAMP 24 10.89 T185
TH PUMP FRICTION CLAMP 24 10.89 T2344
TJ PUMP SHOULDER CLAMP 24 10.89 T504
TR7 MOTOR CLAMP 24 10.89 T772
TR7 SEAL FRICTION CLAMP 24 10.89 T2292
TM PUMP SHOULDER CLAMP 24 10.89 T484
TM PUMP FRICTION CLAMP 24 10.89 T773
TN PUMP FRICTION CLAMP 24 10.89 T2287
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 7
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
ADAPTER KITS
DESCRIPTION PART NUMBER
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS 740220
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS 740226
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS 740235
TD INTAKE OR RGS TO TR5 SEAL 740218
TJ / TM / TN INTAKE TO TR5 SEAL 740225
TR7 SEAL TO TR5 MOTOR 740237
TR7 SEAL TO TR7 SEAL 740238
TR4 SEAL TO TR4 SEAL 740211
ADAPTER KITS COMPONENT PARTS
TD INTAKE OR RGS TO TR5 SEAL - BODY
TD INTAKE OR RGS TO TR5 SEAL - COUPLING
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 943803
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000454
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000447
TD INTAKE OR RGS TO TR5 SEAL - BODY
TD INTAKE OR RGS TO TR5 SEAL - COUPLING
TJ / TM / TN INTAKE TO TR5 SEAL - BODY 740266
TJ / TM / TN INTAKE TO TR5 SEAL - COUPLING 9601112
TR7 SEAL TO TR5 MOTOR - BODY 132718
TR7 SEAL TO TR5 MOTOR - COUPLING
TR7 SEAL TO TR7 SEAL - BODY 960641
TR7 SEAL TO TR7 SEAL - COUPLING
TR4 SEAL TO TR4 SEAL - BODY 740250
TR4 SEAL TO TR4 SEAL - COUPLING 740252
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
SEAL TO INTAKE ADAPTORS
DESCRIPTION PART NUMBER
338 CL .750 X 338 ESP BOI OR RGS .687 734 734SS 734XX
338 CL .750 X 338 ESP BOI OR RGS .875 735 735SS 735XX
338 CL .750 X 55 ODI PUMP RPS .687 736 736SS 736XX
338 CL .750 X 55 ODI RGS .875 737 737SS 737XX
400 CL .875 X 400 ESP BOI OR RGS .875 700 700SS 700XX
400 CL .875 X 55 ODI PUMP RPS .688 701 701SS 701XX
400 CL .875 X 55 ODI PUMP RPSLA 1.00 702 702SS 702XX
400 CL .875 X 55 ODI RGS .875 703 703SS 703XX
400 CL .875 X 540 ESP BOI OR RGS 1.187 738 738SS 738XX
400 CL .875 X 70 ODI PUMP KPS .875 739 739SS 739XX
400 CL .875 X 70 ODI PUMP KPSLA 1.250 750 750SS 750XX
400 CL .875 X 70 ODI RGS 1.125 751 751SS 751XX
513 CL 1.00 X 55 ODI PUMP RPS .688 710 710SS 710XX
513 CL 1.00 X 55 ODI PUMP RPSLA 1.00 711 711SS 711XX
513 CL 1.00 X 55 ODI RGS .875 712 712SS 712XX
513 CL 1.00 X 400 ESP BOI OR RGS .875 713 713SS 713XX
513 CL 1.00 X 70 ODI PUMP KPS .875 714 714SS 714XX
513 CL 1.00 X 70 ODI PUMP KPSLA 1.250 715 715SS 715XX
513 CL 1.00 X 70 ODI RGS 1.125 716 716SS 716XX
513 CL 1.00 X 540 ESP BOI OR RGS 1.187 717 717SS 717XX
338/375 ESP .750 X 338 CL PUMP OR RGS .625 758 758SS 758XX
338/375 ESP .750 X 338 CL PUMP OR RGS .687 759 759SS 759XX
338/375 ESP .750 X 400 CL PUMP .687 760 760SS 760XX
338/375 ESP .750 X 400 CL HV PMP / RGS .875 761 761SS 761XX
338/375 ESP .750 X 55 ODI PUMP RPS .688 762 762SS 762XX
338/375 ESP .750 X 55 ODI PUMP RPSLA 1.00 763 763SS 763XX
338/375 ESP .750 X 55 ODI RGS .875 764 764SS 764XX
400 ESP .875 X 338 CL PUMP OR RGS .625 765 765SS 765XX
400 ESP .875 X 338 CL PUMP OR RGS .687 766 766SS 766XX
400 ESP .875 X 400 CL PUMP .687 704 704SS 704XX
400 ESP .875 X 55 ODI PUMP RPS .688 705 705SS 705XX
400 ESP .875 X 55 ODI PUMP RPSLA 1.00 706 706SS 706XX
400 ESP .875 X 55 ODI RGS .875 707 707SS 707XX
400 ESP .875 X 513 CL BOI OR RGS .875 768 768SS 768XX
400 ESP .875 X 70 ODI PUMP KPS .875 769 769SS 769XX
400 ESP .875 X 70 ODI PUMP KPSLA 1.25 770 770SS 770XX
400 ESP .875 X 70 ODI RGS 1.125 771 771SS 771XX
400 ESP .875 X 540 ESP BOI OR RGS 1.187 772 772SS 772XX
400 ESP .875 X 400 CL HV PUMP/RGS .875 799 799SS 799XX
540 ESP 1.187 X 400 CL PUMP .687 718 718SS 718XX
540 ESP 1.187 X 55 ODI PUMP RPS .688 719 719SS 719XX
540 ESP 1.187 X 55 ODI PUMP RPSLA 1.00 720 720SS 720XX
540 ESP 1.187 X 55 ODI RGS .875 721 721SS 721XX
540 ESP 1.187 X 513 CL BOI OR RGS .875 722 722SS 722XX
540 ESP 1.187 X 70 ODI PUMP KPS .875 723 723SS 723XX
540 ESP 1.187 X 70 ODI PUMP KPSLA 1.250 724 724SS 724XX
540 ESP 1.187 X 70 ODI RGS 1.125 725 725SS 725XX
540 ESP 1.187 X 400 ESP BOI OR RGS .875 740 740SS 740XX
540 ESP 1.187 X 400 CL HV PMP/RGS .875 773 773SS 773XX
540 ESP 1.187 X 562 CL PUMP 1.187 774 774SS 774XX
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 9
Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
SEAL TO INTAKE ADAPTORS
DESCRIPTION PART NUMBER
55 ODI .875 X 338 CL PUMP OR RGS .625 785 785SS 785XX
55 ODI .875 X 338 CL PUMP OR RGS .687 786 786SS 786XX
55 ODI .875 X 400 CL HV PMP / RGS .875 787 787SS 787XX
55 ODI .875 X 513 CL BOI OR RGS .875 788 788SS 788XX
55 ODI .875 X 562 CL PUMP 1.187 789 789SS 789XX
55 ODI .875 X 400 ESP BOI OR RGS .875 708 708SS 708XX
55 ODI .875 X 400 CL PUMP .687 709 709SS 709XX
55 ODI .875 X 540 ESP BOI OR RGS 1.187 790 790SS 790XX
70 ODI KTE 1.00 X 400 CL PUMP .687 726 726SS 726XX
70 ODI KTE 1.00 X 400 ESP BOI OR RGS .875 727 727SS 727XX
70 ODI KTE 1.00 X 513 CL BOI OR RGS .875 728 728SS 728XX
70 ODI KTE 1.00 X 540 ESP BOI OR RGS 1.187 729 729SS 729XX
70 ODI KTE 1.00 X 400 CL HV PMP / RGS .875 791 791SS 791XX
70 ODI KTE 1.00 X 562 CL PUMP 1.187 792 792SS 792XX
70 ODI KETM 1.125 X 400 CL PUMP .687 730 730SS 730XX
70 ODI KETM 1.125 X 400 ESP BOI OR RGS .875 731 731SS 731XX
70 ODI KETM 1.125 X 513 CL BOI OR RGS .875 732 732SS 732XX
70 ODI KETM 1.125 X 540 ESP BOI / RGS 1.187 733 733SS 733XX
70 ODI KETM 1.125 X 400 CL HV PMP/RGS .875 795 795SS 795XX
70 ODI KETM 1.125 X 562 CL PUMP 1.187 796 796SS 796XX
MOTOR TO SEAL ADAPTORS
375 CL X 325 / 375 ESP .75 798 798SS 798XX
450 CL 1.00 X 400 ESP .875 800 800SS 800XX
450 CL 1.00 X 540 ESP 1.187 801 801SS
450 CL 1.00 X 55 ODI .875 802 802SS
450 CL 1.00 X 70 ODI 1.125 803 803SS
544 CL 1.125 X 540 ESP 1.187 804 804SS
544 CL 1.125 X 70 ODI 1.125 805 805SS
562 CL 1.250 X 540 1.187 806 806SS 806XX
562 CL 1.250 X 70 ODI 1.125 807 807SS
375 ESP X 338 CL .750 809 809SS
456 ESP 1.125 X 400 CL .875 810 810SS
456 ESP 1.125 X 513 CL 1.00 811 811SS
456 ESP 1.125 X 55 ODI .875 812 812SS
456 ESP 1.125 X 70 ODI 1.125 813 813SS
456 ESP 1.187 X 400 CL .875 814 814SS
456 ESP 1.187 X 513 CL 1.00 815 815SS
456 ESP 1.187 X 55 ODI .875 816 816SS
456 ESP 1.187 X 70 ODI 1.125 817 817SS
540 ESP 1.187 X 513 CL 1.00 818 818SS
540 ESP 1.187 X 70 ODI 1.125 819 819SS
540 ESP 1.375 X 513 CL 1.00 820 820SS
540 ESP 1.375 X 70 ODI 1.125 821 821SS
55 ODI 1.00 X 400 CL .875 822 822SS
55 ODI 1.00 X 513 CL 1.00 823 823SS
55 ODI 1.00 X 400 ESP .875 824 824SS 824XX
55 ODI 1.00 X 540 ESP 1.187 825 825SS
70 ODI 1.312 X 513 CL 1.00 826 826SS
70 ODI 1.312 X 540 ESP 1.187 827 827SS 827XX
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009
Date:
Company:
Well Name:
Reservoir:
Field Name:
Location:
Analyst:
Comments
Well Data
MD TVD OD Weight Grade Con- ID Drift
(ft | m) (ft | m) (in | mm) (lb/ft | kg/m) nection (in | mm) (in | mm)
Base Prod. Interval
Datum MD: ft | m Datum Temperature: F | C
Datum TVD: ft | m Wellhead temperature: F | C
Deviation Survey
MD TVD Angle MD TVD Angle
( ft | m ) ( ft | m ) ( deg ) ( ft | m ) ( ft | m ) ( deg )
DLS
( /100' | 90m )
DLS
( /100' | 90m )
PBTD
Tubing
Tubing
Casing
Liner
Liner
Open Hole
Top Prod. Interval
Sandstone Limestone
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 1
Shaft HP Limitations
These charts are intended as general guidelines
only. Refer to Technical Bulletins or Application
Briefs for most recent detailed information. (For more
information, contact your Wood Group ESP
representative.)
COMPONENT
STANDARD
MATERIAL
HIGH
STRENGTH
ULTRA
HIGH
STRENGTH
MOTORS 4130 4130 HS
SEALS
MONEL K-500
OR
NITRONIC 50
INCONEL 718
INCONEL 718
HS
GAS
SEPARATORS
NITRONIC 50 HS INCONEL 718
INCONEL 718
HS
PUMPS
MONEL K-500
OR
NITRONIC 50
INCONEL 718
INCONEL 718
HS
TABLE 1
SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
4130 STEEL 121 100
TR-3 UT
4130 HS STEEL 149 124
4130 STEEL 81 67
TR-3 CT
4130 HS STEEL 109 91
4130 STEEL 100 83
TR-3 UT HTI
4130 HS STEEL 120 100
4130 STEEL 60 50
TR-3 CT HTI
4130 HS STEEL 80 67
TR3-UT-HTI-HP 4130 HS STEEL 162 136
TR3-CT-HTI-HP
0.984
4130 HS STEEL 122 103
E37 HSS 0.984 4130 HS STEEL 270 225
TR-4 STD 4130 STEEL 490 408
TR-4 HSS
1.181
4130 HS STEEL 662 550
TR-5/E56 STD 4130 STEEL 775 645
TR-5/E56 HSS
1.377
4130 HS STEEL 1050 870
TABLE 2 MOTORS
SERIES
SHAFT
DIA
MATERIAL
HP @
60 HZ
HP @
50 HZ
TR-3 STD NITRONIC-50 HS 125 104
TR-3 HSS
0.687
INCONEL 718 200 167
TR-387/TR-4 STD NITRONIC-50 HS 256 213
TR-387/TR-4 HSS INCONEL 718 410 342
TR-4 UHSS
0.875
INCONEL-718 HS 522 435
TR-5 / TR-538 /
TR-675 STD
NITRONIC-50 HS 637 531
TR-5 / TR-538 /
TR-675 HSS
1.188
INCONEL 718 1019 849
TABLE 3 GAS SEPARATORS
SERIES
SHAFT
DIA
MATERIAL
HP @
60 HZ
HP @
50 HZ
TA STD NITRONIC-50 HS 125 104
TA HSS
0.687
INCONEL 718 200 167
TR-387 / TD STD NITRONIC-50 HS 256 213
TD HSS INCONEL 718 410 342
TD UHSS
0.875
INCONEL-718 HS 522 435
TE/TG/TH/TJ/TM STD NITRONIC-50 HS 637 531
TE/TG/TH/TJ/TM HSS INCONEL 718 1019 849
TE/TG/TH/TJ/TM UHSS
1.188
INCONEL-718 HS 1350 1125
TN STD 1.5 NITRONIC-50 HS 1000 833
TABLE 4 INTAKES
SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
TR-3 STD
MONEL /
NITRONIC
160 133
TR-3 HSS
0.750
INCONEL 718 256 213
TR-4 STD
MONEL /
NITRONIC
256 213
TR-4 HSS INCONEL 718 410 342
TR-4 UHSS
0.875
INCONEL 718 HS 522 435
TR-5 STD
MONEL /
NITRONIC
637 531
TR-5 HSS
1.188
INCONEL 718 1019 849
TR-5 AR
MONEL /
NITRONIC
637 531
TR-5 AR HSS INCONEL 718 1019 849
TR-5 AR UHSS
1.375
(Has a
1.188
spline) INCONEL 718 HS 1340 1100
TR-562 STD
MONEL /
NITRONIC
690 575
TR-562 HSS
1.375
INCONEL 718 1100 917
TR-7 STD
MONEL /
NITRONIC
1000 833
TR-7 HSS
1.500
INCONEL 718 1600 1333
TR-950 STD
MONEL /
NITRONIC
2100 1750
TR-950 HSS
2.000
INCONEL 718 3375 2813
TABLE 5 SEALS
SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
TD STD
MONEL /
NITRONIC
44 37
TD HSS
0.500
INCONEL 718 70 58
TA/TD STD
MONEL /
NITRONIC
94 78
TA/TD HSS
0.625
INCONEL 718 150 125
TA/TD - STD
MONEL /
NITRONIC
125 104
TA/TD HSS INCONEL 718 200 167
TA/TD UHSS
0.687
INCONEL 718 HS 255 212
TD/TG/TE - STD
MONEL /
NITRONIC
256 213
TD/TG/TE - HSS INCONEL 718 410 342
TD/TG/TE - UHSS
0.875
INCONEL 718 HS 522 435
TG/TE/TH- STD MONEL K500 375 312
TG/TE/TH - HSS INCONEL 718 600 500
TG/TE/TH - UHSS
1.000
INCONEL 718 HS 765 638
TE/TH/TJ/TM STD
MONEL /
NITRONIC
637 531
TE/TH/TJ/TM HSS INCONEL 718 1019 849
TE/TH/TJ/TM UHSS
1.188
INCONEL 718 HS 1300 1083
TM STD
MONEL /
NITRONIC
760 633
TM HSS INCONEL 718 1216 1013
TM UHSS
1.375
INCONEL 718 HS 1550 1290
TN STD
MONEL /
NITRONIC
1000 833
TN HSS INCONEL 718 1600 1333
TN UHSS
1.500
INCONEL 718 HS 2040 1700
TABLE 6 PUMPS
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 2
ENGINEERING TABLES
Pumps 50 Hz 2917 RPM
Const. Stage
Housing
Pressure
Limit
PSI
Model Series
O.D.
MM
Flt. Cprsn. Pancake
Mixed
Flow
Recommended
Operating
Range
M
3
/Day
Maximum
Downthrust
Per Stage
Cprsn.
Pump
Lbs.
BHP
per
Stage
S/O
Head
Per
Stage
Meters Std.
Hi.
Pr.
TA-400 X X X 40-72 15.1 0.07 5.0
TA-550 X X X 53-93 15.7 0.08 4.8
TA-900 X X X 87-140 15.8 0.10 4.6
TA-1200 X X X 120-200 15.5 0.12 4.4
TA-1500 X X X 132-265 16.0 0.18 4.0
TA-2200
338 85.85
X X 166-364 0.19 4.2
6000 6000
TD-150 X X X 11-37 17.0 0.05 5.0
TD-300 X X X 26-60 18.4 0.06 5.1
TD-460 X X X 40-79 22.2 0.08 5.9
TD-650 X X X 60-106 20.2 0.13 7.0
TD-850 X X X 73-135 21.0 0.18 6.9
TD-1250 X X X 106-199 30.1 0.30 7.4
TD-1750 X X X 159-278 11.0 0.22 6.2
TD-2200 X X X 185-371 12.4 0.36 7.0
TD-3000 X X X 265-490 11.9 0.37 5.9
TD-4300 X X X 397-689 15.6 0.58 5.9
TD-6000
400 101.60
X X X 464-994 18.8 0.82 6.2
5000 6000
TG-4000 513 130.30 X X X 424-636 29.5 0.90 11.4 5000 6000
TE-1500 X X X 106-298 34.7 0.79 15.2
TE-2700 X X X 199-437 36.8 0.90 14.8
TE-3300 X X X 291-596 41.4 1.59 15.9
TE-4200 X X X 344-649 64.6 1.78 14.4
TE-5500 X X X 464-967 35.4 1.63 13.1
TE-7000 X X X 530-1285 25.7 1.99 13.5
TE-7200 X X X 530-1285 25.7 1.99 13.3
TE-11000
538 135.65
X X 1060-1855 49.3 2.55 10.6
6000 6000
TH-15000 X X 1325-2517 49.3 5.27 14.8
TH-20000
562 142.75
X X 1987-3113 70.1 6.77 15.5
3000 3600
TJ-7500 X X 662-1457 59.0 3.41 17.0
TJ-9000 X X 662-1722 81.9 5.09 24.8
TJ-12000 X X 994-2385 100.0 6.60 22.0
TJ-20000
675 171.45
X X 1590-3445 132.0 7.31 21.4
3000 3600
A X X 1855-3180 232.6 11.28 31.1
B X X 1722-3047 194.7 8.33 26.0
TM
19000
C X X 1656-2981 158.3 7.24 21.2
TM
24000
A X X 1855-4239 229.2 17.36 31.3
B X X 2650-3842 193.5 16.38 26.5
C X X 2583-3776 154.9 11.92 21.2
TM25000
862 218.95
X X 1855-4504 253.5 20.41 35.1
2000 2400
A X X 4107-5962 642.4 34.08 45.5
B X X 3710-5697 534.8 25.52 37.9
TN
35000
C
950 241.30
X X 3378-5167 448.1 19.82 31.8
2300 2760
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 3
ENGINEERING TABLES
Pumps 50 Hz 2917 RPM
Maximum Number of Stages Using
Shaft
Thrust Brg.
Load Capacity
Lbs.
Thrust Brg.
(Ref Seal Section)
BHP Limit Floater Pump Cprsn. Pump
Shaft Housing
Model
Dia.
MM
Area
MM
2
Std. HS
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
#
HS
#
Std.
#
Hi Pr
#
TR 3 Seal Section
TA-400 413 1181 165 1231 1969 870 870
TA-550 414 1184 159 967 1547 872 872
TA-900 435 1243 159 796 1274 916 916
TA-1200
15.875 197.93 78 125
461 1316 161 645 1031 969 969
TA-1500 413 1179 157 581 929 1050 1050
TA-2200
17.463 239.50 104 167
875
2500
391 1118 545 873 998 998
TR 4 Seal Section
TD-150 12.700 126.68 37 58 715 3965 323 782 1244 708 849
TD-300 448 2485 299 1231 1969 693 832
TD-460 326 1807 248 752 1203 504 605
TD-650 324 1796 272 589 942 501 601
TD-850
15.875 197.93 78 125
329 1824 262 437 699 509 610
TD-1250 254 1408 183 353 565 475 570
TD-1750 303 1682 501 474 758 568 681
TD-2200
17.463 239.50 104 167
269 1489 442 286 457 502 603
TD-3000 196 1087 460 576 922 594 713
TD-4300 197 1091 352 365 584 596 715
TD-6000
22.225
387.95
213
341
992 5500
188 1042 293 261 418 570 684
TR 5 Seal Section
TG-4000 25.400 506.71 313 500 2008 10200 157 800 346 346 554 308 370
TE-1500 154 784 294 269 431 277 277
TE-2700 159 806 277 236 378 285 285
TE-3300
22.225 387.95 213 341
148 752 246 134 214 266 266
TE-4200 125 635 158 175 281 294 294
TE-5500 137 697 288 191 306 322 322
TE-7000 133 677 397 157 251 313 313
TE-7200
25.400 506.71 313 500
135 687 397 157 251 317 317
TE-11000 30.163 715.14 531 849
2008 10200
207 208 333 399 399
TH-15000 207 101 161 143 171
TH-20000
30.163 715.14 531 849 2008 10200
145 78 125 137 164
TR562 Seal Section
TJ-7500 296 155 249 124 149
TJ-9000 214 104 167 85 102
TJ-12000 175 80 129 96 115
TJ-20000
30.163 715.14 531 849 17500
133 73 116 99 119
A 75 47 75 45 54
B 90 64 102 54 65
TM
19000
C 111 73 117 67 80
A 76 31 49 44 53
B 90 32 52 53 64
TM
24000
C
30.163 715.14 531 849
113 45 71 67 80
TM25000 34.925 958.00 633 1013
17500
69 31 50 40 48
A 27 24 39 36 43
B 33 33 52 43 51
TN
35000
C
38.100
1140.09
833
1333
17500
39 42 67 51 61
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 4
ENGINEERING TABLES
Pumps 60 Hz 3500 RPM
Const. Stage
Housing
Pressure
Limit
PSI
Model Series
O.D.
Inches
Flt. Cprsn. Pancake
Mixed
Flow
Recommended
Operating
Range - BPD
Maximum
Downthrust
Per Stage
Cprsn.
Pump
Lbs.
BHP
per
Stage
S/O
Head
Per
Stage
Ft. Std.
Hi.
Pr.
TA-400 338 3.38 X X X 300-540 21.8 0.12 23.5 6000 6000
TA-550 X X X 400-700 22.6 0.14 22.9
TA-900 X X X 660-1060 22.7 0.17 21.8
TA-1200 X X X 900-1500 22.3 0.21 20.6
TA-1500 X X X 1000-2000 23.0 0.31 19
TA-2200 X X 1250-2750 0.33 20
TD-150 X X X 80-280 24.5 0.081 23.5
TD-300 X X X 200-450 26.5 0.11 24.0
TD-460 X X X 300-600 32.0 0.18 33
TD-650 X X X 450-800 29.1 0.23 33.2
TD-850 X X X 550-1020 30.2 0.31 32.7
TD-1250 X X X 800-1500 43.3 0.51 35.0
TD-1750 X X X 1200-2100 15.8 0.38 29.3
TD-2200 X X X 1400-2800 17.9 0.63 33.1
TD-3000 X X X 2000-3700 17.2 0.64 28.0
TD-4300 X X X 3000-5200 22.5 1.01 27.9
TD-6000
400 4.00
X X X 3500-7500 27.0 1.41 29.2
5000 6000
TG-4000 513 513 X X X 3200-4800 42.5 1.56 54.0 5000 6000
TE-1500 X X X 800-2250 50.0 1.37 72.0
TE-2700 X X X 1500-3300 53.0 1.56 70.0
TE-3300 X X X 2200-4500 59.7 2.75 75.0
TE-4200 X X X 2600-5400 93 3.08 68.0
TE-5500 X X X 3500-7300 51.0 2.82 62.0
TE-7000 X X X 4000-9700 37.0 3.44 63.8
TE-7200 X X X 4000-9550 37.0 3.44 62.9
TE-11000
538 5.38
X X 8000-14000 71.0 4.41 50.0
6000 6000
TH-15000 X X 10000-19000 71.0 9.10 70.0
TH-20000
562 5.62
X X 15000-23500 101.0 11.70 73.0
3000 3600
TJ-7500 X X 5000-11000 85.0 5.90 80.5
TJ-9000 X X 5000-13000 118.0 8.80 117.0
TJ-12000 X X 7500-18000 144.0 11.40 104.0
TJ-16000 X X 12000-18000 145.0 12.25 93.5
TJ-20000
675 6.75
X X 12000-26000 190.0 12.63 101.0
3000 3600
A X X 14000-24000 335.0 19.50 147.0
B X X 13000-23000 280.3 14.40 123.0
TM
19000
C X X 12500-22500 227.9 12.51 100.0
A X X 14000-32000 330.0 30.0 150.2
B X X 20000-29000 278.7 28.30 125.0
TM
24000
C X X 19500-28500 223.0 20.60 100.0
TM25000
862 8.62
X X 14000-34000 365.0 35.26 166.0
2000 2400
A X X 31000-45000 925.0 58.89 215.0
B X X 28000-43000 770.1 44.10 179.0
TN
35000
C
950 9.50
X X 25500-39000 645.3 34.25 150.0
2300 2760
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 5
ENGINEERING TABLES
Pumps 60 Hz 3500 RPM
Maximum Number of Stages Using
Shaft
Thrust Brg.
Load Capacity
Lbs.
Thrust Brg.
(Ref Seal Section)
BHP Limit Floater Pump Cprsn. Pump
Shaft Housing
Model
Dia.
In.
Area
In.
2
Std. HS
Std.
@230F
(Max.)
#
Hi-Ld
@250F
(Max.) #
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
#
HS
#
Std.
#
Hi
Pr
#
TR 3 Seal Section
TA-400 320 881 126 783 1253 590 590
TA-550 329 904 122 671 1074 605 605
TA-900 345 950 121 553 885 636 636
TA-1200
0.625 0.3068 94 150
366 1005 123 448 716 673 673
TA-1500 328 901 120 403 645 729 729
TA-2200
0.688 0.3712 125 200
1000 2750
311 854 379 606 693 693
TR 4 Seal Section
TD-150 0.500 0.1963 44 70 596 3004 245 543 864 491 590
TD-300 373 1882 226 855 1367 481 578
TD-460 272 1369 188 522 836 350 420
TD-650 270 1361 206 409 654 348 417
TD-850
0.625 0.3068 94 150
274 1382 199 303 485 353 424
TD-1250 212 1067 139 245 392 330 396
TD-1750 253 1274 380 329 526 394 473
TD-2200
0.688 0.3712 125 200
224 1128 335 198 317 349 419
TD-3000 163 823 349 400 640 413 495
TD-4300 164 826 267 253 406 414 497
TD-6000
0.875
0.6013
256
410
1190 6000
157 789 222 182 290 396 475
TR 5 Seal Section
TG-4000 1.000 0.7854 375 600 2410 11000 131 599 259 240 385 214 257
TE-1500 129 587 220 187 299 193 193
TE-2700 132 604 208 164 263 198 198
TE-3300
0.875 0.6013 256 410
123 563 184 93 149 185 185
TE-4200 104 476 118 122 195 204 204
TE-5500 114 522 216 133 213 224 224
TE-7000 111 507 297 109 174 217 217
TE-7200
1.000 0.7854 375 600
113 514 297 109 174 220 220
TE-11000 1.188 1.1085 637 1019
2410 11000
155 144 231 277 277
TH-15000 155 70 112 99 119
TH-20000
1.188 1.1085 637 1019
109 54 87 95 114
TR562 Seal Section
TJ-7500 226 108 173 86 103
TJ-9000 163 72 116 59 71
TJ-12000 134 56 89 67 80
TJ-20000
1.188 1.1085 637 1019 19250
101 50 81 69 82
A 1.188 1.1085 637 1019 57 33 52 31 38
B 69 44 71 38 45
TM
19000
C 84 51 81 46 55
A 58 21 34 31 37
B 69 23 36 37 44
TM
24000
C 86 31 49 46 55
TM25000 1.375 1.4849 760 1216
19250
53 22 34 28 33
A 21 17 27 25 30
B 25 23 36 30 36
TN
35000
C
1.500 1.7671 1000 1600 19250
30 29 47 35 43
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 6
ENGINEERING TABLES
Model STD Motors
300 Series Motors (3.75 O.D.) 400 Series Motors (4.56 O.D.) 500 Series Motors (5.44 O.D.)
H.P. Volts H.P. Volts H.P. Volts
60
Hz
50
Hz
60
Hz
50
Hz
Amps
60
Hz
50
Hz
60 Hz
50
Hz
Amps
60
Hz
50
Hz
60
Hz
50
Hz
Amps
7.5 6.3 410 342 14 10 8.3 435 363 15 290 241 45
10.5 8.8 390 325 20.5 435 363 23 440 367 29
315 263 35.5
15 12.5
610 508 16 755 629 17
400 333 28 450 375 28.5
20 16.7
1020 850 12 15 12.5
900 750 14
20 16.7
750 625 17 435 363 45
18 15 265 220 51 410 342 39 710 592 28
387 323 38 690 575 22
30 25
1215 1013 16
19.5 16.3
630 525 23
25 20.8
810 675 20 435 363 60
330 275 51.5 425 354 44.5 730 608 36
440 367 38.5
30 25
750 625 25.5 880 733 30 22.5 18.8
730 608 23 400 333 55
40 33.3
1325 1104 20
370 308 51 675 563 33 450 375 72
500 417 37
35 29.2
750 625 28 725 604 45 25.5 21.3
630 525 30 420 350 62 905 754 34
770 642 33 1270 1058 25
880 733 29
50 41.7
1375 1146 22
40 33.3
1295 1079 20 425 354 91
675 563 47 645 538 59
815 679 39 870 725 45
955 796 33 970 808 39
1070 892 31 1085 904 35
50 41.7
1210 1008 27
60 50
1320 1100 30
640 533 59 755 629 60
810 675 47 1015 846 45
970 808 39
70 58.3
1265 1054 35
1330 1108 29 865 721 60
60 50
1945 1620 20 1160 967 45
540 450 82.5
80 66.6
2180 1817 23
750 625 60 705 588 90
945 788 47 835 696 76
1135 946 39 1070 892 60
1310 1092 35 1255 1046 50
70 58.3
1885 1570 24 1450 1208 45
635 529 80
100 83.3
2170 1808 29
860 717 60 855 713 88
1085 904 46 1030 858 73
1310 1092 39 1295 1079 59
80 66.7
2155 1796 24 1450 1208 45
90 75 710 592 81
120 100
2165 1804 33
960 800 59 925 771 88
Model E56 Motors
1135 946 50
130 108.3
1125 938 67
H.P. Volts 1220 1017 46 985 821 90
1460 1216 39 1210 1008 67 60
Hz
50
Hz
60
Hz
50
Hz
Amps
1930 1608 31
140 116.7
2015 1679 44
200 166.7 1403 1169 86 100 83.3 775 646 84 1075 896 87
250 208.3 1754 1462 86 1075 896 59 1240 1033 76
2055 1712 73 1355 1129 46
150 125
2105 1754 44
2355 1962 64 2205 1838 28.5 825 688 122
3858 3215 40
1190 992 60
1115 929 88.5
300 250 1744 1453 104 1487 1239 48 1423 1186 71
2105 1754 86
110 91.7
2380 1983 30 2003 1669 50
350 291.7 2034 1695 104 930 775 84
160 133.3
2185 1821 46
2455 2046 86 1040 867 76 945 788 120
3718 3098 58 1125 938 70 1275 1063 89
400 333.3 1847 1539 135 1295 1079 59 1945 1621 59
2325 1937 104 1625 1354 46
180 150
2260 1883 50
2806 2338 86
120 100
2245 1871 35 1100 917 115
2616 2180 104 1415 1179 89
450 375 1960 1633 140
200 166.7
2140 1783 54
2350 1958 116 1135 946 127
3698 3081 75
225 187.5
2235 1863 64
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 7
ENGINEERING TABLES
Model THD Motors
300 Series Motors (3.75 O.D.) 400 Series Motors (4.56 O.D.) 500 Series Motors (5.44 O.D.)
H.P. Volts H.P. Volts H.P. Volts
60
Hz
50
Hz
60
Hz
50
Hz
Amps
60
Hz
50
Hz
60
Hz
50
Hz
Amps
60
Hz
50
Hz
60
Hz
50
Hz
Amps
10 8.3 455 379 17 15 12.5 505 421 20 30 25 515 429 37
15 12.5 445 371 26 20 16.5 480 400 28 880 733 22
25 20.8 385 320 49 675 563 20 1190 992 15
490 408 39 30 25 525 437 38 45 37.5 505 421 58
1100 917 19 870 725 23 830 691 36
30 25 455 379 50 35 29.5 465 387 49 1415 1179 21
745 621 30 780 650 28 60 50 505 421 77
35 29.2 390 325 68 915 763 25 850 708 46
520 433 51 45 37.5 495 413 59 1025 854 39
865 721 30 870 725 34 1545 1288 26
40 33.3 440 367 68 50 41.5 455 379 71 75 62.5 525 437 93
595 496 49 770 642 42 845 704 58
750 625 40 855 710 36 1055 879 44
60 50 490 408 83 1480 1233 32
895 746 44 1605 1338 28
1025 854 39 90 75 750 625 76
1505 1254 27 1015 846 58
75 62.5 785 654 63 1130 942 50
945 787 52 1265 1041 45
1110 925 44 1540 1283 39
1245 1037 41 105 87.5 880 733 77
1405 1171 36 1185 988 58
90 75 745 620 79 1475 1229 45
940 783 63 120 100 1010 841 77
1130 941 52 1355 1129 58
1545 1288 39 2545 2121 30
2260 1883 27 150 125 975 812 98
105 87.5 630 525 110 1250 1041 77
870 725 80 1465 1221 65
1100 917 63 1690 1408 58
1320 1100 52 2530 2108 37
1525 1271 47 180 150 1200 1000 94
120 100 740 616 107 1510 1258 76
1000 833 80 2030 1691 58
1260 1050 61 2525 2104 43
1525 1271 52 195 162.5 1310 1092 87
2505 2088 32 210 175 1150 958 116
135 112.5 825 687 108 1410 1175 87
1115 929 79 2350 1958 57
1320 1100 67 225 187.5 1255 1046 112
1420 1183 61 1445 1204 98
1695 1413 52 2455 2046 57
2245 1871 41 240 200 1300 1083 114
150 125 900 750 112 1660 1383 92
1250 1041 79 2335 1946 65
1575 1313 61 2550 2125 59
2565 2138 38 270 225 1485 1238 115
165 137.5 1385 1154 80 2270 1892 76
1728 1440 64 2635 2196 65
2765 2304 40 300 250 1285 1071 149
180 150 1080 900 112 1510 1258 127
1210 1008 101 1650 1375 115
1310 1091 93
2495 2079 70
1505 1254 79
2610 2175 47
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 8
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 9
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 10
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 11
Copyright Wood Group ESP March 2009
ENGINEERING TABLES
API Tubular Goods
SIZE
INCHES (MM)
DIAMETER
INCHES / MM
NOMINAL OD
THREAD
WEIGHT
LB / FT OD ID DRIFT
COUPLINGOD
INCHES / MM
API LINE PIPE:
1- (31.8) 11-1/2 V 2.30 1.660 / 42.2 1.380 / 35.1 2.054 / 52.2
1- (38.1) 11 to 11-1/2V 2.75 1.900 / 48.3 1.610 / 40.1 2.200 / 55.9
2 (50.8) 2-3/8 (60.3) 11-1/2 V 3.75 2.375 / 60.3 2.067 / 52.5 2.875 / 73.0
3 (76.2) 3-1/2 (88.9) 8 V 7.70 3.500 / 88.9 3.068 / 77.9 4.000 / 101.6
4 (101.6) 4- (114.3) 8 V 11.00 4.500 / 114.3 4.026 / 102.3 5.200 / 132.1
6 (152.4) 6-5/8 (168.4) 8 V 19.45 6.625 / 168.3 6.065 / 167.8 7.390 / 187.7
8 (203.2) 8-5/8 (219.2) 8 V 25.55 8.625 / 219.1 8.071 / 205.0 9.625 / 244.5
API TUBING (NON UPSET):
1- (38.1) 10 RD 2.75 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.200 / 55.8
2 (50.8) 2-3/8 (60.3) 10 RD 4.00 2.375 / 60.3 2.041 / 51.8 1.947 / 49.5 2.875 / 73.03
2- (63.5) 2-7/8 (73.0) 10 RD 6.40 2.875 / 73.0 2.441 / 62.0 2.347 / 59.6 3.500 / 88.9
3 (76.2) 3- (88.9) 10 RD 7.70 3.500 / 88.9 3.068 / 77.9 2.943 / 74.8 4.250 / 108.0
3- (88.9) 4 (101.6) 8 RD 9.50 4.000 / 101.6 3.548 / 90.1 3.423 / 87.0 4.750 / 120.7
API TUBING (EXTERNAL UPSET):
1- (38.1) 10 RD 2.90 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.500 / 63.5
2 (50.8) 2-3/8 (60.3) 8 RD 4.70 2.375 / 60.3 1.995 / 50.7 1.901 / 48.3 3.063 / 77.8
2- (63.5) 2-7/8 (73.0) 8 RD 6.50 2.875 / 73.0 2.441 / 62.0 2.347 / 59.61 3.668 / 93.2
3 (76.2) 3- (88.9) 8 RD 9.30 3.500 / 88.9 2.992 / 76.0 2.867 / 72.8 4.500 / 114.3
3- (88.9) 4 (101.6) 8 RD 11.00 4.000 / 101.6 3.476 / 88.3 3.351 / 85.1 5.000 / 127.0
4 (101.6) 4- (114.3) 8 RD 12.75 4.500 / 114.3 3.958 / 100.5 3.833 / 97.4 5.563 / 141.3
API TUBING REGULAR CASING:
8 RD 9.50 4.090 / 103.9 3.965 / 100.7
8 RD 11.60 4.000 / 101.6 3.875 / 98.43
4- (114.3)
8 RD 13.50
4.500 / 114.3
3.920 / 99.56 3.795 / 96.39
5.000 / 127.0
8 RD 14.00 5.012 / 127.3 4.887 / 124.1
8 RD 17.00 4.892 / 124.3 4.767 / 121.1
8 RD 20.00 4.778 / 121.4 4.653 / 118.2
5- (139.7)
8 RD 23.00
5.500 / 139.7
4.670 / 118.61 4.545 / 115.44
6.050 / 153.7
8 RD 17.00 6.135 / 155.8 6.010 / 152.7
8 RD 24.00 5.921 / 150.4 5.796 / 147.2
8 RD 28.00 5.791 / 147.09 5.666 / 143.91
6-5/8 (168.4)
8 RD 32.00
6.625 / 168.4
5.675 / 144.14 5.550 /140.97
7.390 / 187.7
8 RD 20.00 6.456 / 164.0 6.331 / 160.8
8 RD 23.00 6.366 / 161.7 6.241 / 158.5
8 RD 26.00 6.276 / 159.4 6.151 / 156.2
8 RD 29.00 6.184 / 157.07 6.059 / 153.89
7 (177.8)
8 RD 32.00
7.000 / 177.8
6.094 / 154.78 5.959 / 151.35
7.656 / 194.5
8 RD 28.00 8.017 / 203.6 7.892 / 200.5
8 RD 32.00 7.921 / 201.19 7.796 / 198.0
8 RD 36.00 7.825 / 198.8 7.700 / 195.6
8-5/8 (219.1)
8 RD 40.00
8.625 / 219.1
7.725 / 196.21 7.600 / 193.04
9.625 / 244.5
8 RD 36.00 8.921 / 226.6 8.765 /222.6
8 RD 40.00 8.835 / 224.4 8.679 / 220.5
8 RD 47.00 8.681 / 220.49 8.525 / 216.53
9-5/8 (244.5)
8 RD 53.50
9.625 / 244.5
8.535 / 216.78 8.379 / 212.82
10.625/ 269.9
8 RD 40.50 10.050 / 255.3 9.894 / 251.3
10-3/4 (273.1)
8 RD 55.50
10.750/ 273.1
9.760 / 247.9 9.604 / 243.9
11.750/ 298.5
8 RD 48.00 12.715/ 323.0 12.559/ 319.0
13-3/8 (339.9)
8 RD 68.00
13.375/ 339.9
12.415/ 315.3 12.259/ 311.4
14.375/ 365.1
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 12
Intentionally left Blank
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 13
ENGINEERING TABLES
Gravity Correction Table
Weight (Density) Fluid Head
Gallon Cubic
Foot
Barrel Pressure per Foot Height per Pound
Buoyancy
Factor
Degrees
API
Specific
Gravity
Pounds Lbs / Sq In Feet Totally Immersed
60.0 0.739 6.16 46.1 259.0 0.320 3.13 0.906
59.0 0.743 6.20 46.4 260.0 0.322 3.11 0.905
58.0 0.747 6.23 46.6 262.0 0.324 3.09 0.905
57.0 0.751 6.26 46.8 263.0 0.325 3.08 0.904
56.0 0.755 6.30 47.1 265.0 0.327 3.06 0.904
55.0 0.759 6.33 47.4 266.0 0.329 3.04 0.903
54.0 0.763 6.36 47.6 267.0 0.330 3.03 0.903
53.0 0.767 6.40 47.9 269.0 0.332 3.01 0.902
52.0 0.771 6.43 48.1 270.0 0.334 2.99 0.902
51.0 0.775 6.46 48.3 271.0 0.336 2.98 0.901
50.0 0.780 6.51 48.7 273.0 0.338 2.96 0.901
49.0 0.784 6.54 48.9 275.0 0.340 2.94 0.900
48.0 0.788 6.57 49.2 276.0 0.341 2.93 0.900
47.0 0.793 6.61 49.5 278.0 0.343 2.92 0.899
46.0 0.797 6.65 49.8 279.0 0.345 2.90 0.898
45.0 0.802 6.69 50.0 281.0 0.348 2.87 0.898
44.0 0.806 6.72 50.3 282.0 0.349 2.87 0.897
43.0 0.811 6.76 50.6 284.0 0.351 2.85 0.897
42.0 0.816 6.81 50.9 286.0 03354 2.82 0.896
41.0 0.820 6.84 51.2 287.0 0.355 2.82 0.896
40.0 0.825 6.88 51.5 289.0 0.357 2.80 0.895
39.0 0.830 6.92 51.8 291.0 0.359 2.79 0.894
38.0 0.835 6.96 52.1 292.0 0.362 2.76 0.894
37.0 0.840 7.01 52.4 294.0 0.364 2.75 0.893
36.0 0.845 7.05 52.7 296.0 0.366 2.73 0.892
35.0 0.850 7.09 53.0 298.0 0.368 2.72 0.892
34.0 0.855 7.13 53.3 299.0 0.370 2.70 0.891
33.0 0.860 7.17 53.6 301.0 0.372 2.69 0.891
32.0 0.865 7.21 53.9 303.0 0.375 2.67 0.890
31.0 0.871 7.26 54.3 305.0 0.377 2.65 0.889
30.0 0.876 7.31 54.7 307.0 0.380 2.63 0.889
29.0 0.882 7.36 55.1 309.0 0.382 2.62 0.887
28.0 0.877 7.40 55.4 311.0 0.384 2.60 0.887
27.0 0.893 7.45 55.7 313.0 0.387 2.58 0.886
26.0 0.898 7.49 56.0 315.0 0.389 2.57 0.885
25.0 0.904 7.54 56.4 317.0 0.392 2.55 0.885
24.0 0.910 7.59 56.8 319.0 0.394 2.54 0.884
23.0 0.916 7.64 57.2 321.0 0.397 2.52 0.883
22.0 0.922 7.69 57.5 323.0 0.399 2.51 0.883
21.0 0.928 7.74 57.9 325.0 0.402 2.49 0.882
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 14
ENGINEERING TABLES
Gravity Correction Table (continued)
Weight (Density) Fluid Head
Gallon
Cubic
Foot
Barrel Pressure per Foot Height per Pound
Buoyancy
Factor
Degrees
API
Specific
Gravity
Pounds Lbs / Sq In Feet Totally Immersed
20.0 0.934 7.79 58.3 327.0 0.405 2.47 0.881
19.0 0.940 7.78 58.7 329.0 0.407 2.46 0.880
18.0 0.946 7.89 59.0 331.0 0.410 2.44 0.879
17.0 0.953 7.95 59.5 334.0 0.413 2.42 0.879
16.0 0.959 8.00 59.8 336.0 0.416 2.40 0.878
15.0 0.966 8.06 60.3 339.0 0.419 2.39 0.877
14.0 0.973 8.11 60.7 342.0 0.421 2.38 0.876
13.0 0.979 8.16 61.0 343.0 0.424 2.36 0.876
12.0 0.986 8.22 61.5 345.0 0.427 2.34 0.874
11.0 0.993 8.28 61.9 348.0 0.430 2.33 0.874
1.00 8.34 62.4 350.0 0.433 2.31 0.873
1.01 8.40 62.8 353.0 0.436 2.29 0.872
1.03 8.60 64.3 361.0 0.447 2.24 0.869
1.06 8.80 65.8 370.0 0.457 2.19 0.866
10.0
Degrees
API or
Pure
Water
1.08 9.00 67.3 378.0 0.468 2.14 0.862
1.10 9.20 68.8 386.0 0.478 2.09 0.860
1.13 9.40 70.3 395.0 0.488 2.05 0.856
1.15 9.60 71.8 403.0 0.499 2.00 0.853
1.154 9.625 72.0 404.0 0.500 2.00 0.853
1.18 9.80 73.3 412.0 0.509 1.96 0.850
1.20 10.0 74.8 420.0 0.519 1.93 0.847
1.22 10.2 76.3 428.0 0.530 1.89 0.844
1.25 10.4 77.8 437.0 0.540 1.85 0.841
1.27 10.6 79.3 445.0 0.551 1.81 0.838
1.29 10.8 80.8 454.0 0.561 1.78 0.835
1.32 11.0 82.3 462.0 0.571 1.75 0.832
1.34 11.2 83.8 470.0 0.582 1.72 0.829
1.37 11.4 85.3 479.0 0.592 1.69 0.826
1.39 11.6 86.8 487.0 0.603 1.66 0.823
1.41 11.8 88.3 496.0 0.613 1.63 0.820
1.44 12.0 89.8 504.0 0.623 1.61 0.817
1.46 12.2 91.3 512.0 0.634 1.58 0.814
1.49 12.4 92.8 521.0 0.644 1.55 0.810
1.51 12.6 94.3 529.0 0.655 1.53 0.808
1.53 12.8 95.8 538.0 0.665 1.50 0.804
1.56 13.0 97.2 546.0 0.675 1.48 0.801
1.58 13.2 98.7 554.0 0.686 1.46 0.798
1.61 13.4 100.0 563.0 0.696 1.44 0.795
1.63 13.6 102.0 571.0 0.706 1.42 0.792
Salt
Water
1.65 13.8 103.0 580.0 0.717 1.39 0.789
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 15
Copyright Wood Group ESP January 2000
ENGINEERING TABLES
Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current Power Factor ratio of true to apparent power
Amperes unit of current or rate at flow of
electricity.
Watthour unit of electrical work; indicates
expenditure of electrical power of one
watt for one hour.
Volt unit of electromotive force Horsepower A measure of time rate of doing work;
equivalent to raising 33,000-lbs one ft.
in one minute. 1 hp = 746 watts
Ohm unit of resistance Torque Formulas:
Ohms Law for DC
Current
Ohms
Electromotive Force / Resistance
Volts / Amperes
N
HPx5252
T =
DC Direct Current Where: T = Torque (lb-ft)
HP = Horsepower
N = Speed (RPM)
Volt Amperes unit of apparent power T = F x R
Megohm 1,000,000 Ohms Where: F = Force (lbs)
R = Radius (ft)
Watt unit of true power
= volt amperes x power factor
To Find Formula Inflow Performance Relationships for
Solution Gas Drive Wells (Below Bubble Point)
Brake HP
Pump%Eff x 3960
SpGr HeadFeet x x GPM
2
Pr
Pwf
0.80
Pr
Pwf
0.20 1
Max Qo
Qo
=
Brake HP
Pump%Eff x 136,000
SpGr HeadFeet x x BPD
Pr Static Reservoir Pressure at
Producing Zone
HP Input
(Three Phase)
746
PF x 1.732 Volt x x Amp
Pwf Flowing Wellbore Pressure at
Producing Zone
Qo Production Rate at Pwf HP Input
(Three Phase)
KW x 1.34
Qo Max Production Rate at 100% Drawdown, Pwf = 0
Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency
BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts
Formulas for Determining Kilowatts, KVA, Horsepower and Amperes
Alternating Current
Desired Data
Single Phase Three Phase
Kilowatts
1000
Pf x Amps x Volts
1000
Pf x Amps x Volts x 1.732
Kilovolt Ampere
1000
Amps x Volts
1000
Amps x Volts x 1.732
Horsepower (Output)
100 x 746
Pf x Eff x Amps x Volts
100 x 746
Pf x Eff x Amps x Volts x 1.732
Amperes (When HP is known)
HP x Eff x Volts
746 x HP
PF x Eff x Volts x 1.732
746 x HP
Amperes (When Kilowatts are known)
PF x Volts
1000 x Kilowatts
PF x Volts x 1.732
1000 x Kilowatts
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 16
Abbreviations, Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current
Amperes
(Amp) (A)
Unit of current or rate at flow of
electricity.
Ohms Law for DC
Current
Ohms
Electromotive Force / Resistance
Volts / Amperes
API American Petroleum Institute
P
B
Bubble Point Pressure
AR Abrasion Resistant PBTD Plug Back Total Depth
ASSY Assembly PIP Pump Intake Pressure
BEP Best Efficiency Point PMP Pump
BHT Bottom Hole Temperature Power Factor (PF) Ratio of true to apparent power
BO Bolt-On
P
R
Reservoir Pressure
BPD Barrels Per Day PSD Pump Setting Depth
Pump % Eff Pump Percent Efficiency Brake Horsepower
(BHP)
The net effective power of a prime
mover
P
WF
Producing Bottom Hole Pressure
BRG Bearing Q Volume Flow Rate
C
P
Wellhead Casing Pressure
Qmin Minimum volumetric flow rate
CONST Construction Qmax Maximum volumetric flow rate
CMP Compression Stage SHD Shroud
DC Direct Current Sp Gr Specific Gravity
DLS Dog Leg Severity SST Stainless Steel
STBPD Stock Tank Barrels Per Day Drift Guaranteed minimum inside
diameter of API tubulars STD Standard
EFF Efficiency STGS Stages
FLT Floater Stage STL Steel
FT Feet TA 338 Series Equipment
GLR Gas / Liquid Ratio 400 Series Equipment
GOR Gas / Oil Ratio
TD
Total Depth
GPM Gallons Per Minute TE 538 Series Equipment
GS Gas Separator
T
F
Tubing Friction Loss
TG 513 Series Equipment
TH 562 Series Equipment
Horsepower (HP) A measure of time rate of doing
work; equivalent to raising 33,000-
lbs one ft. in one minute. 1 hp =
746 watts
THD Motors rated for wellbore conditions
HL High Load TJ 675 Series Equipment
HIPR High Pressure TM 862 Series Equipment
HSG Housing TN 950 Series Equipment
HSS High Strength Shaft
T
P
Wellhead Tubing Pressure
Hz Hertz TVD True Vertical Depth
ID Inside Diameter Unit of electromotive force
KG Kilograms
Volt ( )
Surface Voltage
KW Kilowatts Volt Amperes Unit of apparent power
LBS Pounds
M Meters
Watt unit of true power
= volt amperes x power factor
MCF Thousand cubic feet
MD Measured Depth
Megohm 1,000,000 Ohms
Watt-hour Unit of electrical work; indicates
expenditure of electrical power of
one watt for one hour.
MMSCF Million cubic feet WC Water Cut
MTR Motor
Y
G
( SG
g
)
Gas Specific Gravity
NO Number
Y
O
( SG
o
)
Oil Specific Gravity
OD Outside Diameter
Y
W
( SG
w
)
Water Specific Gravity
Ohm Unit of resistance
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 17
Copyright Wood Group ESP January 2000
ENGINEERING TABLES
Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current Power Factor ratio of true to apparent power
Amperes unit of current or rate at flow of
electricity.
Watthour unit of electrical work; indicates
expenditure of electrical power of one
watt for one hour.
Volt unit of electromotive force Horsepower A measure of time rate of doing work;
equivalent to raising 33,000-lbs one ft.
in one minute. 1 hp = 746 watts
Ohm unit of resistance Torque Formulas:
Ohms Law for DC
Current
Ohms
Electromotive Force / Resistance
Volts / Amperes
N
HPx5252
T =
DC Direct Current Where: T = Torque (lb-ft)
HP = Horsepower
N = Speed (RPM)
Volt Amperes unit of apparent power T = F x R
Megohm 1,000,000 Ohms Where: F = Force (lbs)
R = Radius (ft)
Watt unit of true power
= volt amperes x power factor
To Find Formula Inflow Performance Relationships for
Solution Gas Drive Wells (Below Bubble Point)
Brake HP
Pump%Eff x 3960
SpGr HeadFeet x x GPM
2
Pr
Pwf
0.80
Pr
Pwf
0.20 1
Max Qo
Qo
=
Brake HP
Pump%Eff x 136,000
SpGr HeadFeet x x BPD
Pr Static Reservoir Pressure at
Producing Zone
HP Input
(Three Phase)
746
PF x 1.732 Volt x x Amp
Pwf Flowing Wellbore Pressure at
Producing Zone
Qo Production Rate at Pwf HP Input
(Three Phase)
KW x 1.34
Qo Max Production Rate at 100% Drawdown, Pwf = 0
Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency
BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts
Formulas for Determining Kilowatts, KVA, Horsepower and Amperes
Alternating Current
Desired Data
Single Phase Three Phase
Kilowatts
1000
Pf x Amps x Volts
1000
Pf x Amps x Volts x 1.732
Kilovolt Ampere
1000
Amps x Volts
1000
Amps x Volts x 1.732
Horsepower (Output)
100 x 746
Pf x Eff x Amps x Volts
100 x 746
Pf x Eff x Amps x Volts x 1.732
Amperes (When HP is known)
HP x Eff x Volts
746 x HP
PF x Eff x Volts x 1.732
746 x HP
Amperes (When Kilowatts are known)
PF x Volts
1000 x Kilowatts
PF x Volts x 1.732
1000 x Kilowatts
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 18
Conversion Factors
MULTIPLY BY TO OBTAIN MULTIPLY BY TO OBTAIN
Length Weight
Feet 0.3048 Meters Kilograms 2.6792 Pounds (Troy)
Inches 25.4 Millimeters Tons (Long) 2722.22 Pounds (Troy)
Area Tons (Short) 2430.55 Pounds (Troy)
Square Inches 6.4516 Sq. Centimeters Tons (Metric) 1000 Kilograms
Volume Linear Weight
Cubic Feet 7.481 Gallons Kgs. / Meter 0.672 Pounds / Foot
0.02832 Cubic Meters Pounds / Foot 1.488 Kgs. / Meter
Cubic Inches 16.387 Cu. Centimeters Pressure
Barrels (US Pet.) 5.6146 Cubic Feet Atmospheres 14.7 Pounds / Sq. In.
42 Gallons (US Liq.) 101.32 Kilopascals
0.159 Cubic Meters 29.92 Inches of Mercury
Gallons (Imperial) 1.2009 Gallons (US Liq.) 760 Millimeters of Mercury
Gallons (US Liq.) 231 Cubic Inches Bar 14.5 Pounds / Sq. In.
128 Ounces (US Liq.) 100 Kilopascals
8 Pints (US Liq.) Kilograms / Sq. Cm. 14.22 Pounds / Sq. In.
4 Quarts (US Liq.) 98.07 Kilopascals
Cubic Meters 35.31 Cubic Feet Kilopascals 0.145 Pounds / Sq. In.
6.2898 Barrels (US Pet.) Pounds / Sq. In. 6.895 Kilopascals
Liters 1000 Cu. Centimeters Feet of Water 0.4335 Pounds / Sq. In.
0.001 Cubic Meters 2.989 Kilopascals
Tons (Metric) 36Crude 7.452 Barrels (US Pet.) Meters of Water 1.422 Pounds / Sq. In.
Volume Ratios 9.806 Kilopascals
Cu. Feet / Cu. Foot 5.615 Cu. Feet / Bbl. Density
Cu. Meters / Cu. Meter 5.615 Cu. Feet / Bbl. Pounds / Cu. Ft. 16.0184 Kgs. / Cu. Meter
Velocity Pounds / Cu. In. 27.68 Grams / Cu. Cm.
Feet / Second 0.3048 Meters / Second Pounds / Gallon 7.48 Pounds / Cu. Ft.
Feet / Minute 0.00508 Meters / Second Kgs. / Cu. Meter 0.06243 Pounds / Cu. Ft.
Meters / Second 3.2808 Feet / Second Cubic Feet of Water 62.43 Pounds of Water
Meters / Minute 0.05468 Feet / Second Productivity Index
Volumetric Flow Rate Bbls/Day / Atm 0.06805 Bbls/Day / PSI
Cubic Feet / Day 0.1781 Barrels / Day 0.001569 Cu. Meter/Day / KPa
0.2831 Cu. Meters / Day Bbls/Day / Bar 0.06895 Bbls/Day / PSI
Barrels / Minute 1440 Barrels / Day 0.00159 Cu. Meter/Day / KPa
228.9 Cu. Meters / Day Bbls/Day / Kg/Cm
2
0.07031 Bbls/Day / PSI
Barrels / Hour 24 Barrels / Day 0.001621 Cu. Meter/Day / KPa
3.816 Cu. Meters / Day Bbls/Day / KPa 6.895 Bbls/Day / PSI
Barrels / Day 0.159 Cu. Meters / Day 0.159 Cu. Meter/Day / KPa
Gallons / Minute 34.29 Barrels / Day Bbls/Day / PSI 0.02307 Cu. Meter/Day / KPa
5.451 Cu. Meters / Day Cu. Meter/Day / Atm. 0.4279 Bbls/Day / PSI
Cu. Meters / Hour 150.9 Barrels / Day 0.00987 Cu. Meter/Day / KPa
24 Cu. Meters / Day Cu. Meter/Day / Bar 0.4336 Bbls/Day / PSI
Cu. Meters / Day 6.289 Barrels / Day 0.01 Cu. Meter/Day / KPa
Temperature Cu. Meter/Day / PSI 6.289 Bbls/Day / PSI
Celsius + 17.78 1.8 Fahrenheit 0.145 Cu. Meter/Day / KPa
Celsius + 273 1 Kelvin Cu. Meter/Day / Kg/Cm
2
0.4422 Bbls/Day / PSI
Fahrenheit - 32 0.5555 Celsius 0.01019 Cu. Meter/Day / KPa
Fahrenheit + 460 1 Rankin Cu. Meter/Day / KPa 43.35 Bbls/Day / PSI
Torque Power
Foot-Pound 1.356 Newton-Meters Horsepower 0.7457 Kilowatts
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 19