Contents of Presentation
Theory of circulation Types of circulation Boiling fundamentals Economizer Water walls Drum and its internals
26 May 2012
PMI Revision 00
Circulation in Boiler
The steam generator has to produce steam at highest purity, and at high pressure and temperature required for the turbine. Water must flow through the heat absorption surface of the boiler in order that it be evaporated into steam Natural circulation is the ability of water to circulate continuously, with gravity and changes in temperature being the only driving force known as "thermal head.
The ratio of the weight of water to the weight of steam in the mixture leaving the heat absorption surfaces is called Circulation Ratio.
Cold feedwater is introduced into the steam drum where, because the density of the cold water is greater, it descends in the 'downcomer' towards the lower bottom ring header, displacing the warmer water up into the front tubes. Continued heating creates steam bubbles in the front tubes, which are naturally separated from the hot water in the steam drum, and are taken off.
26 May 2012 PMI Revision 00 3
26 May 2012
PMI Revision 00
26 May 2012
PMI Revision 00
Forced Circulation
However, when the pressure in the water-tube boiler is increased, the difference between the densities of the water and saturated steam falls, consequently less circulation occurs. To keep the same level of steam output at higher design pressures, the distance between the Bottom ring header and the steam drum must be increased, or some means of forced circulation must be introduced. Therefore natural circulation is limited to boiler with drum operating pressure around 175 Kg/cm2.
26 May 2012 PMI Revision 00 6
Natural Circulation
Forced Circulation
Forced Circulation Beyond 180 Kg/cm2 of pressure, circulation is to be assisted with mechanical pumps, to overcome frictional losses. To regulate the flow through various tubes, orifice plates are used. This system is applicable in the high sub-critical regions (say 200 Kg/cm2).
26 May 2012 PMI Revision 00 7
Diff in Density
8
26 May 2012
PMI Revision 00
26 May 2012
PMI Revision 00
10
26 May 2012
PMI Revision 00
11
12
Economiser
Boiler Economiser are feed-water heaters in which the heat from waste gases is recovered to raise the temperature of feed-water supplied to the boiler.
26 May 2012
PMI Revision 00
13
Economiser
The economizer preheats the feed water by utilizing the residual heat of the flue gas. It reduces the exhaust gas temperature and saves the fuel. Modern power plants use steel-tube-type economizers. Design Configuration: divided into several sections : 0.6 0.8 m gap
26 May 2012
PMI Revision 00
14
26 May 2012
PMI Revision 00
15
Finned Economizers
26 May 2012
PMI Revision 00
16
26 May 2012
PMI Revision 00
17
Advantages of Economiser
6oC raise in feed water temperature, by economizers corresponds to a
1% saving in fuel consumption
26 May 2012
PMI Revision 00
18
6oC raise in feed water temperature, by economizers corresponds to a 1% saving in fuel consumption
26 May 2012
PMI Revision 00
19
26 May 2012
PMI Revision 00
20
Type of Construction
Plain Tube : Several banks of tubes with either-in-line or staggered type formation. Staggered arrangement induces more turbulence than the in-line arrangement. This gives a higher rate of heat transfer and requires less surface but at the expense of higher draught loss. Welded Fin-tube : Fin welded design is used for improving the heat transfer.
26 May 2012
PMI Revision 00
21
Boiler Drum
It is an enclosed Pressure Vessel Heat generated by Combustion of Fuel is transferred to water to become steam Process: Evaporation
Steam volume increases to 1,600 times from water and produces tremendous force
26 May 2012
PMI Revision 00
22
26 May 2012
PMI Revision 00
23
SPECIFICATION500MW
MATERIAL - CARBON STEEL LENGTH - 22070 MM OD - 2130 MM ID - 1778 MM DESIGN.PR - 204 KSC WEIGHT(INT) -246 TONNES WITHOUT(INT) 224 TONNES
26 May 2012
PMI Revision 00
25
Drum Internals
The steam drum contains steam separating equipment and internal piping for distribution of chemicals to the water, for distribution of feedwater and for blowdown of the water to reduce solids concentration.
26 May 2012
PMI Revision 00
26
DRUM INTERNALS
1. PRIMARY SEPERATORS
CONSISTS OF BAFFLE ARRANGEMENT DEVICES WHICH CHANGE THE DIRECTION OF FLOW OF STEAM AND WATER MIXTURE 2. SECONDARY SEPERATORS
SEPERATORS EMPLOYING SPINNING ACTION
3. SCREENING DRYERS
26 May 2012
PMI Revision 00
27
Drum Internals
Steam Separator
26 May 2012
PMI Revision 00
28
Downcomers
There are six down comers in (500 MW) which carry water from boiler drum to the ring header. They are installed from outside the furnace to keep density difference for natural circulation of water & steam.
26 May 2012
PMI Revision 00
29
WATER WALLS
HEATING AND EVAPORATING THE FEED WATER SUPPLIED TO THE BOILER FROM THE ECONOMISERS.
THESE ARE VERTICAL TUBES CONNECTED AT THE TOP AND BOTTOM TO THE HEADERS. THESE TUBES RECEIVE WATER FROM THE BOILER DRUM BY MEANS OF DOWNCOMERS CONNECTED BETWEEN DRUM AND WATER WALLS LOWER HEADER. APPROXIMATELY 50% OF THE HEAT RELEASED BY THE COMBUSTION OF THE FUEL IN THE FURNACE IS ABSORBED BY THE WATER WALLS.
26 May 2012 PMI Revision 00 30
26 May 2012
PMI Revision 00
31
OD(MM)
51 51 51 57
26 May 2012
PMI Revision 00
33
Hydro Testing
Need: Method: Ensure pressure instrumentation is ready. Water Filling(10ppm Ammonia, 200 ppm Hydrazine, pH 10) Drainable parts (economizer, water wall and drum) Non Drainable portions filling First pressurization through boiler Fill pump Later pressurization through special purpose pumps. Test pressure and rate of pressure rise and rate of pressure drop as per IBR. After completion system drained and kept under wet preservation.
26 May 2012 PMI Revision 00 34
26 May 2012
PMI Revision 00
35
26 May 2012
PMI Revision 00
36