Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
1 of 50
Document: PL.L1000A.02
Intentionally blank
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
2 of 50
Document: PL.L1000A.02
Contents
PRODUCT TRANSITION GUIDE ........................................................................................................... 1 APPLICABLE DRIVES ........................................................................................................................ 4 DRIVE REPLACEMENT CHECKLIST ..................................................................................................... 5 RATINGS SUMMARY ......................................................................................................................... 6 TERMINAL CONNECTIONS ................................................................................................................. 7 MAIN CIRCUIT TERMINALS ................................................................................................................ 7 CONTROL TERMINALS AND SIGNAL LEVELS ......................................................................................... 8 NETWORK COMMUNICATION TERMINALS .......................................................................................... 10 TERMINAL SIZES AND WIRE GAUGES ............................................................................................... 11 MAIN TERMINAL SIZE/ELECTRICAL WIRING DIFFERENCES .................................................................. 11 CONTROL CIRCUIT TERMINAL SIZE AND GAUGES .............................................................................. 18 DIMENSIONS AND INSTALLATION ADAPTERS ..................................................................................... 19 REQUIRED ADAPTERS AND ATTACHMENTS ....................................................................................... 19 OPEN-CHASSIS (IP00)................................................................................................................... 19 BRAKING RESISTOR INSTALLATION ATTACHMENT .............................................................................. 21 PARAMETER CROSS REFERENCE .................................................................................................... 22 REVISION HISTORY ........................................................................................................................ 50 REFERENCES ................................................................................................................................ 50
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
3 of 50
Document: PL.L1000A.02
Applicable Drives
This document explains the difference between L7B and L1000A for a successful transition L1000A. Be sure to check the application for any peripheral device(s) used. Original Drive: Yaskawa L7B Series General Purpose Drive CIMR-L7B
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
4 of 50
Document: PL.L1000A.02
Dimensions and installation holes differ between L7B and L1000A. Verifying the Installation Location of the Digital Operator When replacing the L7B drive, consider whether the new drive will need to have the digital operator mounted to the same location or if a different location is required. If the same location is important, please consider the mounting position of the digital operator when installing the new unit. Verifying Specialized Specifications Check to see if the L7B drive has a custom nameplate, or any other custom specifications. Verifying Main Circuit Lines (including ground) When replacing the L7B drive, be aware that the position of the main circuit terminal block wiring and wiring order will differ with the newer model. Consider how to rewire the terminal block or if different length cables are required. Verifying Main Circuit Terminal Block and Specifications When replacing the drive, be aware that the position of the terminals may not be the same shape or size in the newer model. Refer to the terminal layout to ensure a proper match.
Drive
Hardware
Main Circuit
Verifying Control Circuit Wiring When replacing the L7B drive, be aware that the position of the control circuit Control Circuit terminal block and wiring order will differ with the newer model. Consider how to rewire the terminal block or if different length cables are required. Refer to the terminal layout in the product instructions to ensure a proper match Software Software Parameter Verifying Custom Software Check the drive software you are currently using to see if it is a standard Yaskawa software. If youre not sure whether the software is standard or not, confirm the software number by contacting your Yaskawa representative. Verifying Parameter Settings Check the parameter settings in the drive you are currently using. Use this replacement guide to set the new parameters to match the current application. For specialized software or for parameters not covered in this replacement guide, contact your Yaskawa representative.
Option Card
Verifying Option Cards Option cards will need to be replaced with new option cards, as L1000A is not compatible with option cards used in L7B models.
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
5 of 50
Document: PL.L1000A.02
Braking Resistor Check to see if the L7B drive currently used has a braking resistor installed. For L7B drives 3.7 kW and smaller using an ERF-type braking resistor, check the following: Verify the braking specifications match the equivalent L1000A replacement unit. See the Braking Resistor Installation Attachment section of this guide for specifications. Use only the braking resistor recommended by Yaskawa. Option & Other Peripherals If planning to use the same ERF-type braking resistor installed to L7B in the new L1000A drive and the cable is too short, replace the cable with a longer one only if the wire specifications are the same. Braking units If braking unit is used, it can simply be transferred over to L1000A as-is. For braking units 30 kW and below, braking transistor protection should be disabled in L1000A (L8-55 = 0). AC or DC Reactor See if the L7B has an AC or DC reactor that can be reused with L1000A Noise Filter If a noise filter is used, it can simply be used with L1000A as-is.
Thoroughly review the instruction manual included with the new drive. To request a catalog, product manual, pricing, or shipping dates, please call your local Yaskawa sales office or representative. For technical questions, support, or other related information, contact a Yaskawa representative.
Ratings Summary
Power Supply Model CIMR-L7B 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 L7B Rated Output Rated Output Carrier Capacity Current Frequency (HP) (A) (kHz) 5 17.5 7.5 25 10 33 15 49 20 64 8 25 80 30 96 40 104 50 128 60 146 75 179 Model CIMR-LU 2A0018 2A0025 2A0033 2A0047 2A0060 2A0075 2A0085 2A0115 2A0115 2A0180 2A0215 L1000A Rated Output Rated Output Carrier Capacity Current Frequency (HP) (A) (kHz) 5 17.5 7.5 25 10 33 15 47 20 60 8 25 75 30 85 40 115 40 115 60 158 75 189
200 V 3-Phase
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
6 of 50
Document: PL.L1000A.02
Model CIMR-LU 4A0009 4A0015 4A0018 4A0024 4A0031 4A0039 4A0045 4A0045 4A0060 4A0075 4A0091 4A0112
Rated Output Rated Output Carrier Capacity Current Frequency (HP) (A) (kHz) 5 7.5 10 15 20 25 30 30 40 50 60 75 9.2 14.8 18 24 31 39 45 45 60 75 91 92
400 V 3-Phase
Terminal Connections
Main Circuit Terminals
Note: The L7B and L1000A drives may have different terminal sizes (depending on capacity). The terminals must be carefully
checked before replacement.
Main Circuit Terminal L7B L1000A Comments
R/L1 S/L2 T/L3 Main circuit power supply input U/T1 V/T2 W/T3 B1 B2 +1 +2 +3 Terminal connections for braking resistor or braking resistor units DC reactor, DC power supply input (positive) DC reactor Braking unit connection (positive) Negative terminals (for DC power supply and braking units) Control power for battery operation Drive output Main circuit power supply input
P0 N0
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
7 of 50
Document: PL.L1000A.02
Grounding: 200 V class: Ground to 100 or less 400 V class: Ground to 10 or less
SN +V V A1
Digital Input Supply Common For frequency reference input +15 V (20 mA max)
* L1000A has a lower voltage level for this terminal. The setting range for the frequency reference needs to be adjusted.
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
8 of 50
Document: PL.L1000A.02
Multi-function analog input Frequency Reference Common Safe Disable input common
Safe Disable input H2* DM+ DM MA MB MC M1 M2 M3 M4 M5 M6 P1 C1 P2 C2 FM AM AC E (G) Multi-function relay output 2 Drive Ready PHC output 1 (During Frequency Output ) PHC output 2 (Not Used/Through Mode) Multi-function analog monitor 1 (Output frequency) Multi-function analog monitor 2 (Output current) Analog Monitor common Ground terminal for shielded line Ground terminal for option cards Safe Disable monitor output Fault output (N.O.) Fault output (N.C.) Contact output common Multi-function relay output 1 Brake Release Command Multi-function relay output 2 Output Contactor Close Command Contact output 30 Vdc 10 mA to 1 A 250 Vac 10 mA to 1 A Minimum Load: 5Vdc, 10mA
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
9 of 50
Document: PL.L1000A.02
Name L7B MEMOBUS Comm. Input Differential input, photocoupler Differential output, photocoupler
L1000A R+ R S+ S IG
R+ R S+ S IG
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
10 of 50
Document: PL.L1000A.02
Model
Model
Terminal Signal R/L1,S/L2,T/L3, U/T1,V/T2,W/T3, ,+1, +2, B1, B2, PO, NO R/L1,S/L2,T/L3,
L7B
23P7
M4
M4 M4 M4 M4 M4 M4 M4 M4 M4 M5
10 (5.5) 10 (5.5) 10 (5.5) 8 (8) 8 (8) 8 (8) 8 (8) 14 (2) 8 (8) 8 (8)
L1000A
2A0018
L7B
25P5
R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, , +1, +2, B1, B2, PO, NO R/L1, S/L2, T/L3,
L7B
27P5
R/L1, S/L2, T/L3,U/T1, V/T2, W/T3, , +1, +2, B1, B2, PO, NO, R/L1, S/L2, T/L3, , +1, +2
M5 M4 M4 M4 M4 M5
L1000A
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
11 of 50
Document: PL.L1000A.02
L7B
2011
M5 M6 M6 M6 M5 M6
35.2 to 53.1 (4 to 6)
6 to 4 (14 to 22)
4 (22)
17.7 to 22.1 (2 to 2.5) 35.2 to 53.1 (4 to 6) 35.2 to 43.99 (4 to 5) 21.99 (2.5) 35.2 to 43.99 (4 to 5)
10 to 6 (5.5 to 14) 8 to 6 (8 to 14) 4 to 2 (22 to 38) 8 to 6 (8 to 14) 4 (22) 10 to 2 (5.5 to 38) 4 to 3 (22 to 30) 10 to 2 (5.5 to 38)
6 (14) 4 (22) 4 (22) 3 (30) 3 (30) 6 (14) 3 (30) 4 (22) 2 (38) 2 (38) 6 (14)
R/L1, S/L2, T/L3, +1, +2, NO L7B 2015 U/T1, V/T2, W/T3 B1, B2, PO
, M6 M5 M6
R/L1, S/L2, T/L3, , +1, +2 L1000A 200 V Class 2A0060 U/T1, V/T2, W/T3, B1, B2
M8 M8 M8 M5 M6 17.7 to 22.1 (2 to 2.5) 35.2 to 53.1 (4 to 6) 79.2 to 87.97 (9 to 10) 21.99 (2.5) 35.2 to 43.99 (4 to 5) 79.2 to 97.4 (9 to 11)
8 to 6 (8 to 14) 6 to 4 (14 to 22) 3 to 2 (30 to 38) 8 to 6 (8 to 14) 4 (22) 10 to 2 (5.5 to 38) 3 to 2 (30 to 38) 10 to 2 (5.5 to 38)
R/L1, S/L2, T/L3, +1, +2, NO L7B 2018 U/T1, V/T2, W/T3 B1, B2, PO
, M8 M5 M6
R/L1, S/L2, T/L3, , +1, +2 L1000A 2A0075 U/T1, V/T2, W/T3 B1, B2
R/L1, S/L2, T/L3, , +1,R1/L11, S1/L21, T1/L31, NO L7B 2022 U/T1, V/T2, W/T3, +3, PO
M8
3 (30)
M6 M8
4 (22)
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
12 of 50
Document: PL.L1000A.02
L7B
2030
79.2 to 97.4 (9 to 11) 154.8 to 197.9 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4)
4 (22)
200 V Class
M10
300 (150)
77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4)
1 (50) 16 (1.25)
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
13 of 50
Document: PL.L1000A.02
1 to 4/0 (50 to 100) 1/0 to 4/0 (60 to 100) 4 to 1/0 (22 to 60)
276.2 to 344.8 (31.4 to 39.2) 154.8 to 197.9 (17.6 to 22.5) 77.4 to 95.0 (8.8 to 10.8) 154.8 to 197.9 (17.6 to 22.5) 11.4 to 12.3 (1.3 to 1.4)
2055
154.8 to 197.9 (17.6 to 22.5) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4) 276.2 to 344.8 (31.4 to 39.2) 11.4 to 12.3 (1.3 to 1.4)
L7B
43P7
R/L1, S/L2, T/L3,U/T1, V/T2, W/T3, , +1, +2, B1, B2, NO, PO
14 to 10 (2 to 5.5)
400 V Class
L7B
45P5
M4
12 to 10 (3.5 to 5.5)
12 (3.5)
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
14 of 50
Document: PL.L1000A.02
L7B
47P5
L7B
4011
M5
22.1 (2.5)
8 10 to 6 (5.5 to 14) 8 10 to 8 (5.5 to 8) 8 to 6 (8 to 14) 10 to 6 (5.5 to 14) 10 to 6 (5.5 to 14) 17.7 to 22.1 (2 to 2.5) 6 (14) 10 to 6 (5.5 to 14) 10 to 8 (5.5 to 8) 35.4 to 53.1 (4 to 6) 35.2 to 43.99 (4 to 5) 10 to 6 (5.5 to 14) 8 to 2 (8 to 38) 8 8 (8) 10 (5.5) 6 (14) 8 (8) 6 (14) 8 (8)
L7B
4015
22.1 (2.5)
R/L1, S/L2, T/L3, , +1, +2 L1000A 4A0031 U/T1, V/T2, W/T3 B1, B2
M5 M5 M5 M6
400 V Class
L7B
4018
, M6
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
15 of 50
Document: PL.L1000A.02
Tightening Torque lb. In. (N M) 22.1 (2.5) 35.2 to 43.99 (4 to 5) 35.4 to 53.1 (4 to 6) 17.7 to 22.1 (2 to 2.5) 35.4 to 53.1 (4 to 6)
6 (14)
L7B
4022
M6
35.2 to 43.99 (4 to 5)
N/A
6 (14)
79.2 to 87.97 (9 to 10) 10 to 1/0 (5.5 to 60) 79.7 to 97.4(9 to 11) 6 to 1(14 to 50) 8 to 4 (8 to 22) 8 to 6 (8 to 14) 4 (22) 6 (14)
L7B
4030
M6
35.2 to 43.99 (4 to 5)
N/A
4 (22)
79.2 to 87.97 (9 to 10) 10 to 3/0 (5.5 to 80) 79.7 to 97.4(9 to 11) 4 to 1(22 to 50) 6 to 3 (14 to 30) 6 (14) 79.2 to 87.97 (9 to 10) N/A 35.2 to 43.99 (4 to 5) 79.2 to 87.97 (9 to 10) 6 to 250 (14 to 125) 79.7 to 97.4 (9 to 11) 3 to 1/0 (30 to 60) 6 to 1/0 (14 to 60) 4 (22) 2 (38) 3 (30) 6 (14) 2 (38)
M8
L1000A
4A0075
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
16 of 50
Document: PL.L1000A.02
L7B
4045
M8 M6 M8
1(50) 4 (22) 3/0 (80) 1/0 to 4/0 (60 to 100) 2/0 (70) 3 to 4/0 (30 to 100) 4 (22) 4 (22)
L7B
4055
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
17 of 50
Document: PL.L1000A.02
L7B
All capacities
AC, SC, A1, +V, S1, S2, S3, S4, S5, S6, S7, MA, MB, MC, M1, M2, M3, M4, M5, M6, BB, BB1, R+, R-, S+, SIG
M2 Phoenix Type
0.5 to 0.6
0.75
E (G) FM, AC, AM, P1, P2, PC, SC, A1, A2, +V, -V, S1, S2, S3, S4, S5, S6, S7, S8, All 200 V Class L1000A MA, MB, MC, M1,M2, M3, 400 V Class capacities M4, M5, M6 H1, H2, HC, DM+, DMIG, R+, R-, S+, S-, E(G)
M3.5
0.8 to 1.0
0.5 to 2.0 Stranded wire 0.25 to 1.0 single conductor 0.25 to 1.5 0.25 to 0.5
1.25
M2
0.22 to 0.25
0.75
M2 Phoenix Type
0.22 to 0.25
0.5
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
18 of 50
Document: PL.L1000A.02
Open-Chassis (IP00)
Voltage Class Capacity HP (kW)
5 (3.7) 7.5 (5.5) 10 (7.5) 15 (11) 20 (15) 25 (18.5) 3-Phase 200 V Class 30 (22) 40 (30) 50 (37) 60 (45) 75 (55) 10.00 15.46 10.98 17.43 (258) (279) (450) 11.81 14.76 23.62 (298) (328) 17.72 28.54 13.78 12.80 27.56 (450) (725) (348) (325) (700) 9.84 22.64 (375) (600) 12.99 (250) (575) 7.67 8.66 15.16 17.13 (254) (400) 10.24 (195) (385) (220) (435) 37.5 44.1 114.6 125.7 172.0 9.80 15.70 (250) (400) 10.20 10.80 17.70 (258) (275) (450) 12.80 21.70 11.10 (325) (550) (283) 17.70 27.80 13.00 (450) (705) (330) 7.67 (195) 8.66 (220) 10.20 (259) 12.80 (325) 15.16 (385) 17.13 (435) 21.10 (536) 26.80 (680) 9.45 13.78 8.27 8.50 13.19 (240) (350) (207) (216) (335) 24.3 8.70 13.80 7.80 (220) (350) (197) 7.60 (193) 13.19 (335) 7.87 11.81 7.87 7.32 11.22 (200) (300) (197) (186) (285) 13.2 15.4 5.51 11.02 7.09 4.96 10.47 (140) (280) (177) (126) (266) 8.8 5.51 10.20 (140) (260) 6.60 (167) 7.10 11.80 7.40 (180) (300) (187) 6.30 (160) 11.22 (285)
External Heatsink
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
19 of 50
Document: PL.L1000A.02
Voltage Class
Capacity HP (kW)
5 (3.7) 7.5 (5.5) 10 (7.5) 15 (11) 20 (15) 25 (18.5) 30 (22) 40 (30) 50 (37) 60 (45) 75 (55)
L1000A W1
Standard Installation
EZZ020801A (100-047-230) EZZ020801A (100-047-230) EZZ020801B (100-047-231) EZZ020801C (100-047-232) EZZ020801D (100-047-233) EZZ020801E (100-047-234) EZZ020801G (100-048-119) N/A
External Heatsink
(122) (249)
6.30 11.22 (160) (285) 7.60 13.19 7.67 15.16 (195) (385) 8.66 17.13
11.9
(275) (450) 10.20 (220) (435) 68.2 12.95 21.36 11.22 10.24 21.06 (325) (550) (283) (258) (535) 10.20 19.50 (259) (495)
79.4
EZZ020801J (100-048-121)
90.4
N/A
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
20 of 50
Document: PL.L1000A.02
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
21 of 50
Document: PL.L1000A.02
Language Selection
A1-00
A1-00
A1-01
A1-01
L7B L1000A A1-01 A1-01 0: Operation only 0: Operation only (monitors only) (monitors only) 1: User Parameters * 1: User Parameters * 2: All parameters 2: All parameters *Set parameters A2-01 through A2-32. L7B A1-02 0: V/f Control 2: Open Loop Vector 3: Closed Loop Vector 6: Closed Loop Vector for PM L1000A A1-02 0: V/f Control 2: Open Loop Vector 3: Closed Loop Vector 7: Closed Loop Vector for PM L1000A A1-03 0: No initialization 1110: User initialize 2220: 2-wire sequence 5550: Reset OP 04
A1-02
A1-02
Initialize Parameters
A1-03
A1-03
0 0
0 0 *If setting A1-01 to 1, refer to the manual and set parameters A2-01 to A2-32. L7B b1-01 0: Operator 1: Control circuit terminal (analog input) 2: MEMOBUS comm. 3: Option card L7B b1-02 0: Operator 1: Control circuit terminal 2: MEMOBUS comm. 3: Option card L7B b1-03 0: Ramp to stop 1: Coast to stop L1000A b1-01 0: Operator 1: Control circuit terminal (analog input) 2: MEMOBUS comm. 3: Option card L1000A b1-02 0: Operator 1: Control circuit terminal 2: MEMOBUS comm. 3: Option card L1000A b1-03 0: Ramp to stop 1: Coast to stop
b1-01
b1-01
b1-03
b1-03
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
22 of 50
Document: PL.L1000A.02
Default
b1-06
b1-06
Operation Selection After Switching to Remote Mode Run Command Selection while in Programming Mode *Up/Down Command Selection while in Programming Mode Phase Order Selection
b1-07
No corresponding parameter in L1000A. L7B b1-08 0: Disabled. 1: Run cmd always accepted 2: Cannot enter Program Mode 0: U-V-W 1: U-W-V *L1000A b1-08 0: Disabled. 1: Up/Do n always accepted 2: Cannot enter Program Mode
b1-08
b1-08
S3-08
b1-14
DC Injection Braking
b2-08
0%
b2-08
0%
Timers
b4-01 b4-02
b4-01 b4-02
0.0 s 0.0 s L1000A Setting Range 0.0Hz to 120.0 Hz 0.0% to 100.0% 0.0% to 100.0% for PM All Control Methods L7B
Dwell Function
b6-01
b6-01*
0.0 %
0.0 s 0.0 % 0.0 s 0.0% 0.05 s L7B b8-01 0: Energy Saving disabled 1: Energy Saving enabled For IPM motors only L1000A b8-01 0: Energy Saving disabled 1: Energy Saving enabled
Droop Control
Droop Control Gain Droop Control Delay Time Energy Saving Control Selection
b8-01
b8-01
b8-16
0.10
b8-16
0.10
b8-17
1.00
b8-17
1.00
Acceleration Time 1
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
23 of 50
Document: PL.L1000A.02
*Motor 2 Accel Time 1 *Motor 2 Decel Time 1 *Motor 2 Accel Time 2 *Motor 2 Decel Time 2 L7B C1-10 0: 0.01 s units 1: 0.1 s units L7B Setting Range 0.0 Hz to 120.0 Hz 0.0% to 100.0% for PM L 000A C1- 0 0: 0.01 s units 1: 0.1 s units L1000A 0.0 % to 100.0 % All Control Methods
C1-10
C1-10
Motor 2 Acceleration Time Motor 2 Deceleration Time Inspection Deceleration Ramp S-Curve Characteristic at Accel Start S-Curve Characteristic at Accel End S-Curve Characteristic at Decel Start S-Curve Characteristic at Decel End S-Curve Below Leveling Speed Slip Compensation Gain Slip Compensation Primary Delay Time Slip Compensation Limit Slip Compensation C2-01 0.50 s
*C1-12 determines the acceleration time for motor 2 as long as d1-27 is not set to 0.00 Hz.
*Sets the deceleration ramp used for inspection run. L7B Setting Range 0.00 s to 2.50 s L1000A 0.00 s to 10.00 s
S-Curve Characteristics
C2-01
0.50 s
0.50 s 0.50 s 0.50 s 0.50 s 1.0 2000 ms *Sets the S-Curve used when the speed reference is lower than the leveling speed setting.
C3-03
200%
C3-03
200% L7B L1000A C3-04 0: Disabled 1: Enabled above 6 Hz 2: Enabled whenever slip compensation is possible
C3-04
C3-04
C3-05
C3-05
L7B L1000A C3-05 C3-05 0: Disabled 0: Disabled 1: Enabled 1: Enabled *Default setting determined by control method
C4-01
1.00
C4-01
1.00
o m p
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
24 of 50
Document: PL.L1000A.02
Default
Torque Compensation Primary Delay Time Torque Compensation at Forward Start Torque Compensation at Reverse Start Torque Compensation Time Constant Torque Compensation Time Constant 2 ASR Proportional Gain 1 ASR Integral Time 1 ASR Proportional Gain 2 ASR Integral Time 2 ASR Primary Delay Time Constant ASR Gain Switching Frequency ASR Integral Limit Speed Control (ASR) ASR Proportional Gain 3 ASR Integral Time 3 ASR Gain Encoder Offset Tuning Speed Control Loop Delay Time during Position Lock Motor Inertia Load Inertia Ratio Proportional Gain Time during Position Lock
C4-02
C4-02
C5-01
*
40.00
*Determined by the control mode selected. Default show here is for when using Closed Loop Vector Control
*
0.500 s 20.00
*
0.500 s 20.00
*
0.500 s 0.004 s
0.500 s 0.004 s
*Determined by the control mode selected. Default show here is for when using Closed Loop Vector Control. L7B Setting Range 0.0 Hz to 400.0 Hz L1000A 0.0 % to 100.0 %
0.500 s
*Determined by the control mode selected. Default show here is for when using Closed Loop Vector Control No corresponding parameter in L1000A.
*Automatically set during ASR or Inertia Auto-Tuning. Automatically set during ASR or Inertia Auto-Tuning. *Determined by the control mode selected. Default show here is for when using Closed Loop Vector Control
C5-20
0.100 s
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
25 of 50
Document: PL.L1000A.02
Default
C6-02
3*
C6-03
1.0 to 15.0 kHz *Determined by o2-04 (Most models are default to 8 khz)
C6-03
8.0 kHz
No corresponding parameter in L1000A. L1000A C6-06 0: 2-phase/3-phase Conversion 1: 2-phase modulation 2: 3-phase modulation
C6-06
C6-09
C6-09
C6-10
C6-11
L1000A Inspection Operation Carrier Frequency C6-21 1 C6-21 0: Carrier Freq = C6-03 1: Carrier Freq = 2 kHz L1000A Carrier Frequency During Initial Motor Pole Search C6-23 0 C6-23 0: Carrier Freq = 2 kHz 1: Carrier Freq = C6-03 *Sets the Speed Reference for the drive when d1-18 it set to 0 or 3. Setting units are determined by o1-03. L7B L1000A Setting Range 0.00 Hz to 120.00 Hz 0.0 % to 100.0 %
d1-01*
0.00 Hz
d1-01*
0.00 %
Frequency Reference 2 Frequency Reference 3 Frequency Reference 4 Frequency Reference 5 Frequency Reference 6 Frequency Reference 7 Frequency Reference 8
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
26 of 50
Document: PL.L1000A.02
Default
d1-18*
d1-18
Frequency Reference
Nominal Speed Intermediate Speed 1 Intermediate Speed 2 Intermediate Speed 3 Re-leveling Speed Inspection Operation Speed Rescue Operation Speed Leveling Speed Motor 2 Speed Reference
d1-28*
0.00 %
d1-29*
0.00 %
* Used when d1-18 = 0 or 3. If the speed reference selected is higher than d1-28 but lower or equal to d1-29, the drive uses inspection speed as the active reference.
L7B Magnetic Field Control Field Forcing Function Selection d6-03 0 d6-03 0 d6-03 0: Disabled 1: Enabled
d6-06
400%
d6-06
400%
V/f Characteristics
E1-01
200 V
E1-01
200 V
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
27 of 50
Document: PL.L1000A.02
Default
E1-03
E1-03
V/f Characteristics
Max Output Frequency Max Voltage Base Frequency Mid. Output Frequency Mid. Output Frequency Voltage Minimum Output Frequency Minimum Output Frequency Voltage
*Depends on the control mode and the V/f pattern selected. *Depends on the control mode and the V/f pattern selected. Double values for 400 V class drives.
*Depends on the control mode and the V/f pattern selected. *Depends on the control mode and the V/f pattern selected. *Depends on the control mode and the V/f pattern selected. Double values for 400 V class drives.
*Depends on the control mode and the V/f pattern selected. *Depends on the control mode and the V/f pattern selected. Double values for 400 V class drives.
Base Voltage
E1-13
0.0 V
E1-13
0.0 V
Motor Parameters
E2-01
E2-01
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
28 of 50
Document: PL.L1000A.02
Default
E2-02
E2-02
Motor De-Coupled Load Current Motor Poles Count Motor Line-to-Line Resistance
* 4 poles *
* 4 poles *
Motor Parameters
E2-06
E2-06
E2-07
0.50
E2-07
0.50
Motor Iron Core Saturation Co-Efficient 2 Motor Mechanical Loss Motor Iron Loss for Torque Compensation Motor Rated Output Motor Iron Core Saturation Co-Efficient 3 Motor 2 Max Output Frequency Motor 2 Max Voltage
E3-04 E3-05
60.0 Hz 200.0 V
*Determined by the control mode selected. *Determined by the control mode selected. Double values for 400 V class drives.
E3-06
60.0 Hz
Motor 2 Mid. Output Frequency Motor 2 Mid. Output Frequency Voltage Motor 2 Minimum Output Frequency Motor 2 Minimum Output Frequency Voltage
*Determined by the control mode selected. *Determined by the control mode selected. Double values for 400 V class drives.
*Determined by the control mode selected. *Determined by the control mode selected. Double values for 400 V class drives.
Motor 2 Parameter
E4-01
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
29 of 50
Document: PL.L1000A.02
Default * * 4Poles * *
Motor 2 Parameter
E5-02
E5-02
E5-03
E5-03
PM Motor Settings
Motor Poles Motor Stator Resistance (Single Phase) Motor d-Axis Inductance Motor q-Axis Inductance Motor Induction Voltage Constant 1 Encoder Offset
32 * * * * 0.0 deg
12 * * * * 0.0 deg PM Motor Settings *Determined by drive capacity. PM Motor Settings *Determined by drive capacity/Set during Auto-Tuning PM Motor Settings *Determined by drive capacity/Set during Auto-Tuning PM Motor Settings *Determined by drive capacity and motor nameplate data. Set during parameter or encoder offset auto-tuning for PM motors.
E5-24
0.0 mv/(r/min)
PG Constant
F1-01*
600
F1-01**
1024
Determined by drive capacity. *CLV/PM mode, maximum setting is 8192 ppr. **CLV/PM mode, maximum setting is 15000 ppr L7B F1-02 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L7B F1-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L1000A F1-02 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L1000A F1-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation
F1-02
F1-02
F1-03
F1-03
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
30 of 50
Document: PL.L1000A.02
Default
F1-04
F1-04
PG Rotation Selection
F1-05
F1-05
PG Division Rate (PG Pulse Monitor) Overspeed Detection Level Overspeed Detection Delay Time Excessive Speed Deviation Detection Level Excessive Speed Deviation Detection Delay Time PG speed Control Card PG Open-Circuit Detection Time Dv3 Detection Selection (CLV/PM) Dv4 Detection Selection (CLV/PM) PG Option Card Disconnection Detection 1 Absolute Encoder Resolution Magnet Position Offset Encoder Copy Selection Encoder Copy Write Permission
2 60 deg 0 0 L1000A F1-29 0: After Spd ref, SFS output and motor speed have matched once. 1: After Spd ref, SFS output has matched once. 2: Always during run No corresponding parameter in L1000A.
F1-29
F1-51
F1-63
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
31 of 50
Document: PL.L1000A.02
Default
F3-01
F3-03
L7B F4-01, F4-03, H4-01, H4-04, o1-01 01: Frequency reference 02: Output frequency 03: Output current 05: Motor speed 06: Output voltage reference
F4-01
F4-01
102
L1000A F4-01, F4-03, H4-01, H4-04, o1-01 101: Frequency reference 102: Output frequency 103: Output current 105: Motor speed 106: Output voltage reference 107: Main circuit DC 07: Main circuit DC voltage voltage 08: Output power 108: Output power 09: Torque ref (Internal) 109: Torque ref (Internal) 15: Freq ref, A1 voltage 113: Freq ref, A1 voltage 16: Freq ref, A2 voltage 114: Freq ref, A2 voltage 17: Freq ref, A3 voltage 115: Freq ref, A3 voltage 18: Secondary current (Iq) 601: Secondary current (Iq) 19: Motor excitation current 602: Motor excitation (Id) current (Id) 20: Output after soft start 116: Output after soft start 21: ASR input 603: ASR input 22: ASR output 604: ASR output 24: PID feedback amount 501: PID feedback amount 26: Output voltage ref (Vq) 605: Output voltage ref (Vq) 606: Output voltage ref 27: Output voltage ref (Vd) (Vd)) 32: ACR output (q-axis) 607: ACR output (q-axis) 33: ACR output (d-axis) 608: ACR output (d-axis) 36: PID input amount 502: PID input amount 37: PID output amount 503: PID output amount 38: PID setpoint 504: PID setpoint 44: ASR output , no filter 625: ASR output , no filter 45: Feed Forward output 626: Feed Forward output Setting units differ between L7B and L1000A. Set L1000A by multiplying F4-02 in L7B by 100. *See the comments column for F4-01. Setting units differ between L7B and L1000A. Set L1000A by multiplying F4-04 in L7B by 100.
Channel 1 Gain Channel 2 Monitor Selection Channel 2 Gain Channel 1 Output Monitor Bias Channel 2 Output Monitor Bias
100.0% 3
*
100.0% 103
*
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
32 of 50
Document: PL.L1000A.02
Default
F4-07
F4-07
F4-08
F4-08
F5-01
F5-01
Channel 2 Output Selection Channel 3 Output Selection Channel 4 Output Selection Channel 5 Output Selection Channel 6 Output Selection Digital Output Card Channel 7 Output Selection
1 2 4 6 37 0F
1 2 4 6 37 F
F5-06 F5-07
F5-08
0F
F5-08
F5-09
F5-09
L7B F5-09 F5-01=0 F5-02=1 F5-03=2 F5-04=4 0 F5-05=6 F5-06=37 F5-07=F F5-08=F 1: Signed output 2: Output according to F5-01 to 08 L7B F6-01 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L7B F6-02 0: Always detected 1: Detected during run L7B F6-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation
L1000A F5-09 F5-01=0 F5-02=1 F5-03=2 F5-04=4 0 F5-05=6 F5-06=37 F5-07=F F5-08=F 1: Signed output 2: Output according to F5-01 to 08 L1000A F6-01 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L1000A F6-02 0: Always detected 1: Detected during run L1000A F6-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation
F6-01
F6-01
F6-02
F6-02
F6-03
F6-03
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
33 of 50
Document: PL.L1000A.02
Default 2.0 s
F6-06
F6-06
F6-08
H1-01
24 (80)
H1-03
24 (50)
H1-02
14 (84)
H1-04
14 (54)
H1-03
3 (81)
H1-05
3 (51)
H1-04
4 (83)
H1-06
4 (53)
4: Multi-Step Speed Reference 2 5: Multi-Step Speed Reference 3 6: Jog freq ref selection 7: Accel/decel time selection 1 8: Baseblock command (N.O.) 9: Baseblock command (N.C.) F: Not used 14: Fault Reset 15: Fast Stop (N.O.) 16: Motor switch command 17: Fast Stop (N.C.) 17: Fast Stop (N.C.) 18: Timer function input 18: Timer function input 1A: Accel/decel time 1A: Accel/decel time selection 2 selection 2 20: External fault (N.O., 20: External fault (N.O., Always detected, Ramp to Always detected, Ramp to stop) stop) 21: External fault (N.C., 21: External fault (N.C., Always detected, Ramp to Always detected, Ramp to stop) stop) 22: External fault (N.O., 22: External fault (N.O., Detected during run, Ramp Detected during run, Ramp to stop) to stop) 23: External fault (N.C., 23: External fault (N.C., Detected during run, Ramp Detected during run, Ramp to stop) to stop) 24: External fault (N.O., 24: External fault (N.O., Always detected, Coast to Always detected, Coast to stop) stop)
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
34 of 50
Document: PL.L1000A.02
Default
H1-05
6 (F)
H1-07
5 (F)
L7B 25: External fault (N.C., Always detected, Coast to stop) 26: External fault (N.O., Detected during run, Coast to stop) 27: External fault (N.C., Detected during run, Coast to stop) 28: External Fault (N.O., always detected, Fast Stop) 29: External fault (N.C., always detected, Fast Stop)
H1-08
2A: External Fault (N.O., detected during run, Fast Stop) 2B: External fault (N.C., detected during run, Fast Stop) 2C: External fault (N.O., always detected, alarm only) 2D: External fault (N.C., always detected, alarm only) 87: High Speed Limit (Up) 88: High speed Limit (Down) 60: DC Braking command 67: Comm. test mode
L1000A 25: External fault (N.C., Always detected, Coast to stop) 26: External fault (N.O., Detected during run, Coast to stop) 27: External fault (N.C., Detected during run, Coast to stop) 28: External Fault (N.O., always detected, Fast Stop) 29: External fault (N.C., always detected, Fast Stop) 2A: External Fault (N.O., detected during run, Fast Stop) 2B: External fault (N.C., detected during run, Fast Stop) 2C: External fault (N.O., always detected, alarm only) 2D: External fault (N.C., always detected, alarm only) 57: High Speed Limit(Up) 58: High Speed Limit (Down) 5C: Floor Sensor
Digital Inputs
67: Comm. test mode 79: Brake Feedback 2E: External Fault 2E: External Fault (N.O., (N.O., detected during run, detected during run, alarm alarm only) only) 2F: External Fault (N.C., 2F: External Fault (N.C., detected during run, alarm detected during run, alarm only) only) 80: Nominal Speed 50: Nominal Speed 81: Intermediate Speed 51: Intermediate Speed 82: Releveling Speed 52: Releveling Speed 83: Leveling Speed 53: Leveling Speed 84: Inspection Operation 54: Inspection Operation 85: Rescue Operation 55: Rescue Operation 86: Motor Contactor 56: Motor Contactor Feedback Feedback 87: High Speed Limit Switch (UP) 88: High Speed Limit Switch (Down)
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
35 of 50
Document: PL.L1000A.02
Default
H2-01
40
H2-01
50
L7B H2-01 to H2-03 0: During Run 1: Zero Speed 2: Frequency Agree 1 3: User-set frequency agree 1 4: Frequency detection 1 5: Frequency detection 2 6: Drive ready 7: DC bus undervoltage 8: During baseblock 9: Freq ref selection A: Run cmd selection B: Torque detection 1 (N.O.) C: Frequency reference loss D: Braking resistor overheat E: Fault F: Not used 10: Alarm 11: Fault reset 12: Timer function output 13: Frequency agree 2 14: User-Set frequency agree 2 15: Frequency detection 3 16: Frequency detection 4 17: Torque detection 1 (N.C.) 18: Torque detection 2 (N.O.)
L1000A H2-01 to H2-05 0: During run 1: Zero speed 2: Frequency agree 1 3: User-set frequency agree 1 4: Frequency detection 1 5: Frequency detection 2 6: Drive ready 7: DC bus undervoltage 8: During baseblock (N.O.) 9: Freq ref selection A: Run cmd selection B: Torque detection 1 (N.O.)
Digital Outputs
E: Fault F: Through-mode 10: Alarm 11: Fault reset 12: Timer function output 13: Frequency agree 2 14: User-Set frequency agree 2 15: Frequency detection 3 16: Frequency detection 4 18: Torque detection 2 (N.O.)
H2-02
41
H2-02
51
H2-03
H2-03
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
36 of 50
Document: PL.L1000A.02
Default
H2-04
37
1C: Motor selection 1D: Regen during run 1E: Fault restart 1F: Motor overload alarm 20: Drive overheat alarm 2F: Maintenance timer 30: During torque limit 30: During torque limit 33: Zero servo complete 33: Within Position Lock 37: During run 2 37: During frequency output 40: Brake Control 50: Brake Control 51: Output Contactor 41: Output Contactor Control Control 42: Door Zone Reached 52: Door Zone Reached 43: Not Zero Speed 53: Not Zero Speed 54: Light Load Direction 55: Light Load Direction Detection Status 38: Cooling Fan Status 56: Cooling Fan Status 57: Input Phase Loss 46: Hardware Baseblock 1 58: Safe Disable Status 47: Hardware Baseblock 2 3C: Magnet Position Detection Complete 3D: Cooling fan malfunction 61: Rotor detection complete 100-161: 0 to 61 with Inverse Output 1D: Regen during run 1E: Fault restart 1F: Motor overload alarm 20: Drive overheat alarm
L7B H2-01 to H2-03 19: Torque detection 2 (N.C.) 1A: Reverse run 1B: During baseblock 2 (N.C.)
H2-05
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
37 of 50
Document: PL.L1000A.02
Default
H3-01
Terminal A1 in L1000A is multi-functional. L1000A H3-01 0: 0 to +10 V (uses lower limit) 1: 0 to 10 V (no lower limit) L7B L1000A H3-15 H3-02 0: Frequency Reference 0: Speed Reference Bias 1: Torque Compensation 2: Aux Speed Reference 1 3: Aux Speed Reference 2 14: Torque Compensation 1F: Not Used
H3-15
H3-02
H3-16
100.0%
H3-03
100.0%
H3-17
0.0%
H3-04
0.0%
H3-09
Analog Inputs
H3-10
1F*
*For L1000A, see table for A1 Function Selection L7B Setting Range 0.0 % to 1000.0 % L7B Setting Range -100.0 % to 100.0 % L1000A -999.9 % to 999.9% L1000A -999.9 % to 999.9%
H3-11
100.0%
Terminal A2 Input Bias Analog Input Filter Time Constant Offset for Terminal A1
H3-12
0.0%
H3-12
0.03 s
H3-13 H3-16
0.03 s 0
H3-17
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
38 of 50
Document: PL.L1000A.02
Setting Record
H4-02
100.0%
H4-02
100.0%
H4-03
0.0%
H4-03
0.0%
103
50.0% 0.0%
50.0% *See the setting range for H4-01 and H4-02 0.0% L7B H4-07 0: 0 to +10 V output 1: 0 to 10 Vdc output L7B H4-08 0: 0 to +10 V output 1: 0 to 10 Vdc output L1000A H4-07 0: 0 to +10 Vdc output 1: 0 to 10 Vdc output L1000A H4-08 0: 0 to +10 Vdc output 1: 0 to 10 Vdc output
H4-07
H4-07
H4-08
H4-08
Slave Address
H5-01
1F
H5-01
MEMOBUS Communication
H5-02
H5-02
L7B H5-02 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19200 bps
L1000A H5-02 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19200 bps 5: 38400 bps 6: 57600 bps 7: 76800 bps 8: 115200 bps L1000A H5-03 0: No parity 1: Even parity 2: Odd parity L1000A H5-04 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L1000A H5-05 0: Disabled 1: Enabled
H5-03
H5-03
L7B H5-03 0: No parity 1: Even parity 2: Odd parity L7B H5-04 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L7B H5-05 0: Disabled 1: Enabled
H5-04
H5-04
H5-05
H5-05
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
39 of 50
Document: PL.L1000A.02
Default 5ms
H5-07
H5-07
L7B H5-07 0: Disabled (RTS always on) 1: Enabled (RTS enabled during send only)
L1000A H5-07 0: Disabled (RTS always on) 1: Enabled (RTS enabled during send only)
H5-09
2.0 s L1000A H5-10 0: 0.1 V units 1: 1 V units L1000A H5-11 0: Enter Cmd Req. 1: Enter Cmd Not Req. L7B L1000A L1-01 L1-01 0: Disabled 0: Disabled 1: General-purpose motor 1: General-purpose motor protection protection 2: Drive-dedicated motor 2: Drive-dedicated motor protection protection 3: Vector motor protection 3: Vector motor protection 5: PM motor protection 5: PM motor protection (constant torque) (constant torque) *Determined by the control mode selected. L7B Setting Range 0.1 to 5.0 min L1000A 0.1 to 5.0 min
H5-10
H5-11
L1-01
1*
L1-01
L1-02
1.0 min
L1-02
1.0 min
L2-05
190 V
L2-05
190 V
380 V for a 400 class drive. But if E1-01 is set lower than 400, then for set 350 V for L1000A. No corresponding parameter in L1000A. L7B L3-01 0: Disabled 1: Enabled 2: Optimum Tuning L1000A L3-01 0: Disabled 1: Enabled 2: Optimum Tuning
Battery Voltage
L2-11
L3-01
L3-01
Stall Prevention Level during Acceleration Stall Prevention Limit during Acceleration Stall Prevention Selection during Deceleration
150% 50%
L3-02
150%
No corresponding parameter in L1000A. 0 L7B L3-05 0: Disabled 1: Enabled (Decel Time 1) 2: Enabled (Decel Time 2) L1000A L3-05 0: Disabled 1: Enabled (Decel Time 1) 2: Enabled (Decel Time 2)
L3-05
L3-05
Stall Prevention Level during Run Speed Agreement Detection Level uenc y Dete
L3-06 L4-01
150% 0.0 Hz
L3-06 L4-01
150% 0.0 %
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
40 of 50
Document: PL.L1000A.02
L4-05
L4-05
Speed at Reference Loss Door Zone Level Number of Auto Restart Attempts Fault Restart Auto Restart Operation Selection Fault Reset Interval Time UV1 Fault Reset Selection
80 % 0.0 Hz 2 times
80 % 0.0 % 0 times L7B L5-02 0: No output 1: Outputs during restart L1000A L5-02 0: No output 1: Outputs during restart Sets the door zone speed level.
L5-02
L5-02
L5-03 L5-05
2.0 s 0
L5-04 L5-06
10.0 s 0 0: Same as the L5-01 selection. 1: Always automatically reset UV1. L7B L6-01, L6-04 0: Disabled 1: oL3 detection only active during speed agree, operation continues after detection 2: oL3 detection always active during run, operation continues after detection 3: oL3 detection only active during speed agree, output shuts down on an oL3 fault 4: oL3 detection always active during run, output shuts down on an oL3 fault 5: UL3 detection only active during speed agree, operation continues after detection 6: UL3 detection always active during run, operation continues after detection 7: UL3 detection only active during speed agree, output shuts down on an oL3 fault 8: UL3 detection always active during run, output shuts down on an oL3 fault L1000A L6-01, L6-04 0: Disabled 1: oL3 detection only active during speed agree, operation continues after detection 2: oL3 detection always active during run, operation continues after detection 3: oL3 detection only active during speed agree, output shuts down on an oL3 fault 4: oL3 detection always active during run, output shuts down on an oL3 fault 5: UL3 detection only active during speed agree, operation continues after detection 6: UL3 detection always active during run, operation continues after detection 7: UL3 detection only active during speed agree, output shuts down on an oL3 fault 8: UL3 detection always active during run, output shuts down on an oL3 fault
L6-01
L6-01
Torque Detection Level 1 Torque Detection Time 1 Torque Detection Selection 2 Torque Detection Level 2 Torque Detection Time 2 Forward Torque Limit rq ue Li mi
150% 10.0 s 0
*
150% 0.1 s 0
*
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
41 of 50
Document: PL.L1000A.02
No corresponding parameter in L1000A. * Determined by drive capacity. L7B L8-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L7B L8-05 0: Disabled 1: Enabled Determined by drive capacity. L7B L8-07 0: Disabled 1: Enabled (triggered by a single phase loss) 2: Enabled (triggered when two phases are lost) L7B L8-09 0: Disabled 1: Enabled L7B L8-10 0: During run only 1: Fan always on L1000A L8-07 0: Disabled 1: Enabled (triggered by a single phase loss) 2: Enabled (triggered when two phases are lost) L1000A L8-09 0: Disabled 1: Enabled L1000A L8-10 0: During run only 1: Fan always on 2: Temp Controlled Operation L1000A L8-03 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation L1000A L8-05 0: Disabled 1: Enabled
L8-03
L8-03
Input Phase Loss Protection Selection Input Phase Loss Detection Level
L8-05
L8-05
L8-06
L8-07
L8-07
L8-09
L8-09
L8-10
L8-10
L8-11 L8-12
60 s 45
L8-11 L8-12
60 s 40 Set the ambient temperature where the drive is being used. L1000A L8-15 0: Disabled 1: Enabled
L8-15
Soft CLA Selection Output Phase Loss Detection Time Overcurrent Detection Gain
L8-18 L8-20
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
42 of 50
Document: PL.L1000A.02
Default
L8-29
L8-29 0: Disabled 1: Enabled L7B L1000A L1000A does not have an internal cooling fan L1000A L8-32 0: Alarm detection 1: Fault detection L8-35 0: IP00 Enclosure 2: IP00 with top cover L1000A L8-38 0: Disabled 3: Enabled
L8-32
L8-35
L8-38
L8-39
3.0 kHz L1000A L8-55 0: Disabled 1: Enabled L1000A L8-62 0: Ramp to stop 1: Coast to stop 2: Fast Stop 3: Continue operation
L8-55
L8-62
Oscillation Suppression Safe Disable Operation Mode Speed Feedback Detection Control Function Speed Feedback Detection Control (AFR) Gain Speed Feedback Detection Control (AFR) Time Constant Speed Feedback Detection Control (AFR) Time Constant 2 n2-01 n2-02 1.00 50 ms
0 1 1.00 50 ms
n2-03
750 ms
n2-03
750 ms
L7B Feed Forward Control Selection n5-01 0 n5-01 0 n5-01 0: Disabled 1: Enabled Motor Acceleration Time n5-02 * n5-02 * Determined by drive capacity. n5-01
n5-03
1.00
n5-03
1.00
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
43 of 50
Document: PL.L1000A.02
L7B n8-35 Magnet Position Detection Method 0: Detection method 1 n8-35 2 n8-35 1 2: Detection method 2 4: HIPERFACE method 5: EnDat method High Frequency Injection Level High Frequency Injection Amplitude Low Pass Filter Cut-off Freq Inductance Measurement Current Level Output Voltage Limit High Frequency Injection During Rescue High Frequency Injection Amplitude During Rescue Polarity Detection Current n8-36 n8-37 n8-39 n8-46 500 Hz 30.0 % 50 Hz 10.0 % n8-62 n8-81 n8-82 n8-84 200.0 V 90 Hz 15.0 % 100.0 % L1000A Magnet Pole Search Error Detection n8-86 0 n8-86 0: Disabled 1: Enabled No corresponding parameter in L1000A. Double values for 400 V class drives. n8-36 n8-37 500 Hz 20.0 % n8-35
n9-60
0.0 s
n9-60
0.0 s
Current Detection
n9-74
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
44 of 50
Document: PL.L1000A.02
Default
o1-01
o1-01
106
L7B o1-02 0: Frequency reference User Monitor Selection After Power Up o1-02 1 o1-02 1 1: Output frequency 2: Output current 3: Determined by o1-01 o1-02
L1000A 1: Frequency reference 2: Direction 3: Output Frequency 4: Output Current 5: User-selected Monitor
L7B o1-03 0: 0.01 Hz units 1: 0.01% units 2 to 39: r/min units Display Setting / Selection 40 to 39999: User-set units o1-03
L1000A 0: 0.01 Hz units 1: 0.01% units 2: r/min units 3: User-set units o1-10 o1-11 1 to 60000 0 to 3 4: Elevator units 1 5: Elevator units 2 6: Elevator units 3
o1-03
o1-03
o1-10: Determines the units for the frequency reference. o1-11: Sets the decimal point for the frequency reference display. Ex. : For a max output frequency of 200.0, set the following: L7B L1000A Setting value: Setting value: o1-03=3 o1-03=12000 o1-10=2000 o1-11=1 12000 Max value, excluding decimal point o1-10= 2000 digits displayed to the right of the decimal o1-11= 1
L7B Setting Unit for Frequency Constants Related to V/f Characteristics LCD Brightness Length Units Traction Sheave Diameter Roping Ratio Mechanical Gear Ratio S3-13 S3-14 400 mm 2 o1-04 0 o1-04 0 o1-04 0: Hz units 1: r/min units o1-05 3 o1-12 o1-20* o1-21 o1-22 0 400 mm 2 * o1-04
No corresponding parameter in L1000A. 0: Millimeter unit 1: Inch Unit Scales the display unit calculations. *L1000 CLV and CLV/PM Only Sets the ratio (1:1, 1:2, 1:3 or 1:4) Determined by the control method.
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
45 of 50
Document: PL.L1000A.02
Default
o2-01
o2-01
o2-02
o2-02
o2-03
o2-03
o2-04
o2-04
Do not change this setting. Determined by drive capacity. L7B L1000A o2-05 0: ENTER required 1: ENTER key not required L1000A o2-06 0: Disabled 1: Enabled o2-05 0: ENTER required 1: ENTER key not required L7B o2-06 0: Disabled 1: Enabled
Multi-Function Selection
o2-05
o2-05
Operation Selection when Digital Operator is Disconnected Cumulative Operation Time Setting
o2-06
o2-06
o2-07
0H
o4-01
0H L7B o2-08 0: Whenever the power is on 1: During run only *Do not change this setting. L7B Setting Range : 0 to 65535H L1000A Setting Range : 0 to 9999H L7B L1000A o4-11 0: No change L1000A o4-02 0: Whenever the power is on 1: During run only
o2-08
o4-02
Factory Tuning Fan Operation Time (L1000A: Cooling Fan Operation Time Setting)
o2-09 o2-10
0 0H
o2-09 o4-03
* 0H
o2-12
o4-11
o2-12 0: No change
1: Reset U2, U3 parameters 1: Reset U2, U3 parameters Number of Travel Counter Initialize
02-15
04-13
L7B Copy Function o3-01 0: No Action Copy Function Selection o3-01 0 o3-01 0 1: READ 2: COPY 3: VERIFY o3-01
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
46 of 50
Document: PL.L1000A.02
Default
o3-02
o3-02
o4-12
1: Reset the kWh monitor Zero Speed Level at Stop DC Injection Current at Start DC Injection Current at Stop DC Injection/Position Lock Time at Start Brake Sequence DC Injection/Position Lock Time at Stop Brake Release Delay Time S1-01* S1-02 S1-03 S1-04 * 50.0 % 50.0 % 0.40 s S1-01* S1-02 S1-03 S1-04 * 50.0 % 50.0 % 0.40 s In CLV and CLV/PM, S1-04 determines how long Position Lock should be performed. A setting of 0.00 disables this function. In CLV and CLV/PM, S1-05 determines how long Position Lock should be performed. A setting of 0.00 disables this function. Determines the delay time between the start of Position Lock and setting the brake control command in order to release the brake. Determines the delay time between reaching Zero Speed (S1-01) and resetting the brake control command in order to apply the brake. Sets the delay time after the Up/Down command is entered until the internal run command is set. Determines the delay time between shutting off the output of the drive and resetting the contactor control command to release the motor contactor. Sets the motor rated speed. *Slip compensation for leveling speed can be set separately for motoring and regenerative states. This can help improve the accuracy of leveling. Determined by the control method. Determines the speed to begin applying DC Injection (or Position Lock) when the drive is ramping to a stop.
S1-05
0.60 s
S1-05
0.60 s
S1-06
0.20 s
S1-06
0.20 s
Brake Close Delay Time Run Command Delay Time Output Contactor Open Delay Time Motor Rated Speed Slip Compensation Gain in Motoring Mode Slip Compensation Gain in Regenerative Mode Slip Compensation Torque Detection Delay Time Slip Compensation Torque Detection Filter Time Constant
S2-15
Start/Stop Optimization
Position Lock Gain at Start 1 Position Lock Gain at Start 2 (Anti Rollback Gain) Position Lock Gain at Stop Position Lock Bandwidth S1-33 S1-20 S1-21 0.00 5 10
5 0.00 5 10
Sets gain levels 1 and 2 for Position Lock at start to avoid rollback.
Sets the Position Lock gain at stop to keep the car in position until the brake has been applied entirely.
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
47 of 50
Document: PL.L1000A.02
Default 500 ms
0 0.0 % 1000 ms 100 ms 0.00 % 0.00 % 100.0 % 20.0 % -50.0 % 50.0 % 0.0 % 100.0 % 0.0 % 0.0 % 0 0 0.00 1 pulse 0.50 L1000A S4-01 Sets the responsiveness for Anti-Rollback during Position Lock. Sets the amount of pulses for movement detection during Anti-Rollback.
S4-01
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
48 of 50
Document: PL.L1000A.02
Default
S4-02
Light Load Direction Search Time Light Load Direction Search Speed Reference Rescue Operation Torque Limit
S4-06
UPS Power
S4-07
0.0 kVa
S4-08
0: Disabled 1: Enabled until Light Load Detection Search is complete 2: Enabled until stop
DC Bus Voltage During Rescue Operation Rescue Operation Power Supply Deterioration Detection Level
S4-12 S4-13
0V 80.0 % Determines at which level of backup power supply deterioration a PF5 fault is triggered. L1000A S5-01
S3-01
S5-01
Nominal Speed for Short Floor Calculation Short Floor Minimum Constant Speed Time Distance Calculation Acceleration Time Gain Distance Calculation Deceleration Time Gain
When d1-18 is set for 0 or 3, S5-02 determines the rated speed used during Short Floor. Sets the minimum operation time when Short Floor function is enabled.
L1000A Short Floor Operation S5-10 Stopping Method Selection S5-10 0 0: Disabled 1: Direct Landing 2: Leveling Distance Control Deceleration Distance Stop Distance Direct Landing Minimum Speed Level S5-11 S5-12 S5-13 0 mm 0 mm 20.0 % Sets the speed level for the start of Direct Landing.
Doc#: PL.L1000A.02
www.yaskawa.com
February, 2010
49 of 50
Document: PL.L1000A.02
Default
S1-28
S6-01
0: Detect during stop, SE1 manually reset 1: Detect during stop, SE1 automatically reset 2: No SE1 detection
Starting Current Error (SE2) Detection Delay Time Output Current Error (SE3) Detection Delay Time Brake Response Error (SE4) Detection Time Error Detection Overacceleration Detection Level Overacceleration Detection Time
S1-14 S1-15
200 ms 200 ms
200 ms 200 ms 500 ms * 50 ms L1000A Default setting determined by o1-03 display units.
S3-16 S3-17
* 50 ms
S6-10 S6-11
S3-18
S6-12
S6-12 0: Always Enabled 1: During run only L7B L1000A S6-15 0: FrL Disabled 1: FrL Enabled L1000A S3-09 0: FrL Disabled 1: FrL Enabled S6-16 0: No Restart 1: Restart
S3-09
S6-15
S6-16