Signet 2610 Process Optical Dissolved Oxygen Sensor

Features
The Signet 2610 RDO Pro is a rugged, reliable sensor designed to deliver accurate dissolved oxygen (DO) data across a wide measuring range while reducing maintenance costs. It features the latest optical technology for DO measurement and eliminates the replacement of membrane and reference solutions. The Signet 2610 optical sensor cap is calibrated at the factory and requires no field calibration. The optical measurement technology resists abrasion and bleaching allowing for a long life in many harsh applications. The DO sensor has a built in Modbus RS485 and 4 to 20 mA current loop outputs for ease of interface to existing control systems. Additional features include a 10 m (32.8 ft) cable with stripped and tinned ends as well as a titanium thermistor for improved compatibility in salt water applications. Optical DO measurement no flow requirements Rugged construction Calibration built into the measurement cap 2% of range 0 to 20 mg/l One year measurement cap life No membranes or filling solutions Flexible communications, 4 to 20 mA or Modbus (RS485) Measurement Range: 0 to 20 mg/L

LEAD FREE

Pb
COMPLIANT

RoHS

Applications
Municipal and Industrial Wastewater Treatment Drinking Water Reservoir Monitoring Environmental Water Discharge Monitoring Aquatic Life Support

Panel Mount Signet Instruments 8900 9900

Field Mount - Pipe, Tank, Wall Signet Instruments 9900 with 3-8050 Universal Mount Kit

System Overview

ENTER

+
OR

Signet i-GoTM Signal Converter 8058

Signet 2610 Process Optical Dissolved Oxygen Sensor

All sold separately

Specifications
General Sensor Type Transmitter/Local Display Communications Options Maximum Cable Length Internal Mounting Thread Power Requirements 4 to 20 mA output span Performance Salinity Range pH Range Barometric Range Maximum Pressure Range Accuracy (DO) Response Time of Cap Repeatability Resolution Environmental Usage Life of Cap Shelf Life of Cap Operating Temperature IP Rating Compliance Storage Conditions, Cap Storage Conditions, Sensor Warranty Sensor Standards and Approvals Luminescent dissolved oxygen sensor Optional, not required Modbus (RS485), 4 to 20 mA Up to 4000 ft (Modbus and 4 to 20 mA) 1 NPT 12 to 24 VDC 10% regulated 0 to 20 mg/L 0 to 42 PSU, fixed or real-time capable 2 to10 pH 507 to 1115 mbar, fixed or real-time capable 300 psi 0 to 20 mg/L concentration, 0 to 200% saturation 0.1 mg/L, 0 to 8 mg/L, 0.2 mg/L, 8 to 20 mg/L T90: 30 sec T95: 37 sec @ 25 C 0.05 mg/L 0.01 mg/L 1 year from the first instrument reading 24 months from date of manufacture (install within 12 mo. of manufacture) 0 C to 50 C 32 F to 122 F IP-67 with cap off, IP-68 with cap installed Heavy industrial, IEC 61000-6-2:2005 1 C to 60 C 33 F to 140 F, in factory container -5 C to 60 C 23 F to 140 F 3 years from date of manufacture CE, FCC RoHS Compliant, China RoHS

Dimensions
Protective Cap Temperature Sensor 29 mm (1.14 in.)

43.7 mm ( 1.72 in.)

20.3 cm (8.0 in.)

10 m (32.8 ft) standard cable length

Thread 1 NPT x 25 mm (1.0 in.) deep

Ordering Information
Code 159 001 753 159 310 122 Description 3-2610-31 Optical Dissolved Oxygen Sensor (0 to 20 ppm) with Modbus, SDI, and 4 to 20 mA output 3-2610.392 Replacement Optical Dissolved Oxygen Sensor Cap (0 to 20 ppm)

3-2610.099 Rev B (06/12) Georg Fischer Signet LLC 3401 Aerojet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 www.gfsignet.com e-mail: [email protected] Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.