210 Set-Stop Valve 200 Series Valve Elastomer Selection
210 Set-Stop Valve 200 Series Valve Elastomer Selection
210 Set-Stop Valve 200 Series Valve Elastomer Selection
210 Set-Stop Valve and 200 Series Valve Packages Elastomer Selection
Application Bulletin
Bulletin AB03003 Issue/Rev. 1.2 (11/10)
Applies To: Model 210, 2" through 6", Hydraulic Set-Stop Valves and 200 Series Valve Packages
1. Valve Temperature and Pressure Limits The 150 ANSI flanged valve temperature range is -20F to 100F @ 285 PSI maximum working pressure for valve material ASTM A 216 WCB per ASME B16.5. The maximum working pressure is reduced at temperatures above 100F per ASME B16.5. The temperature range of the valve elastomers are in the table below.
Temperature Range -20F to 200F (-28C to 93C) -20F to 200F (-28C to 93C) -20F to 350F (-28C to 177C)
2. Low Temperature Applications For colder climate applications use Elastomer Group 1 and replace Buna-LS (Low Swell) diaphragm with Buna-N diaphragm for improved consistent response of the valve. The elastomers must be compatible with the liquid product in all cases.
4. 200 Series Valve Pilot Elastomers The control pilots used with 200 series valves will have the base elastomer of the valve; i.e., Low Swell Buna valve will have Buna-N pilot elastomers or Viton-A valve will have Viton-A pilot elastomers.
1 LSD and ULSD elastomers may incur increased wear if lubricity additive is not present before flowing through the valve.
Revisions included in AB03003 Issue/Rev. 1.2 (11/10): Ethanol-Neat and Blends added - Group 4.
The specications contained herein are subject to change without notice and any user of said specications should verify from the manufacturer that the specications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact Us link in the left-hand column.
Headquarters: 500 North Sam Houston Parkway West, Suite 100, Houston, TX 77067 USA, Phone: +1 (281) 260 2190, Fax: +1 (281) 260 2191 Measurement Products and Equipment: Erie, PA USA +1 (814) 898 5000 Ellerbek, Germany +49 (4101) 3040 Barcelona, Spain +34 (93) 201 0989 Beijing, China +86 (10) 6500 2251 Buenos Aires, Argentina +54 (11) 4312 4736 Burnham, England +44 (1628) 603205 Dubai, United Arab Emirates +971 (4) 883 0303 Los Angeles, CA USA +1 (310) 328 1236 Melbourne, Australia +61 (3) 9807 2818 Moscow, Russia +7 (495) 5648705 Singapore, +65 6861 3011 Thetford, England +44 (1842) 822900 Integrated Measurement Systems: Corpus Christi, TX USA +1 (361) 289 3400 Kongsberg, Norway +47 (32) 286700 Dubai, United Arab Emirates +971 (4) 883 0303