vacon nxp and nxc superlative performance

the dynamic choice


The Vacon NXP is a state-of-art AC drive for use in all applications where reliability, dynamic performance, precision and power are required.

The quality and reliability of a machine or process is in most cases the result of the precise, dynamic control of AC motors. The Vacon NXP has been designed to provide the best possible control under all circumstances, ensuring high operational quality and availability for the entire lifetime of a system. A forerunner in designing and manufacturing AC drives, Vacon has developed innovative solutions and leading-edge technology for demanding applications and high power ranges. By bringing these solutions to customers, the Vacon NXP opens up new opportunities and helps them create the best and highly innovative products and achieve the most challenging targets.

Features
Full power and voltage range High number of options Wide set of applications adapts the Vacon NXP to virtually any need Controls induction and permanent magnet motors Dynamic open and closed loop vector control Complete range of communications and I/O options Fast drive-to-drive communication

Snap-on fan Robust power module

Removable display

Connection to PC or door installation kit

Separate control unit, exible I/O interface Touch-protected connections

fr4 fr9

fr4
2

fr5

fr6

fr7

fr8

fr9

outstanding flexibility
The Vacon NXP offers, in addition to its control characteristics, a wide choice of products and cabinets for the varying needs in the high-power range.

Three models are available to meet various customer needs as follows: Vacon NXP IP21/IP54 wall-mounted or standalone drives for installation wherever there is space available Vacon NXP high-power IP00 drive modules for installation in the customer's cabinet Vacon NXC robust cabinet drive with maximum exibility and a wide range of options

vacon nxp drive modules

vacon nxp standalone drives

vacon nxc cabinet drives


3

wall-mounted vacon nxp


For the lower power range, Vacon NXP drives are available in a compact IP21 or IP54 enclosure. One of the most compact and complete drives on the market, it has all necessary components integrated a single enclosure.
The wall-mounted units are equipped with internal EMC ltering, and the power electronics are integrated into an all-metal frame. The smaller frame sizes (FR4-FR6) have an integrated brake chopper as standard, and the 380-500 V units can be equipped with an integrated brake resistor. The larger frames (FR7-FR12) can be equipped with an integrated brake chopper as option.

Mains voltage 208240 V, 50/60 Hz, 3

Loadability Motor shaft power 230 V supply Maximum current I S 4.8 7.4 9.6 13.2 15.6 22 25 35 50 62 96 122 150 176 210 280 336 349 444 10% overload P (kW) 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 22 22 30 37 45 55 75 90 50% overload P (kW) 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 22 22 30 37 45 55 75 Frame size FR4 FR4 FR4 FR4 FR4 FR4 FR5 FR5 FR5 FR6 FR6 FR7 FR7 FR7 FR8 FR8 FR8 FR9 FR9 Dimensions and weight W*H*D (mm)/ kg 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 144*391*214/ 8.1 144*391*214/ 8.1 144*391*214/ 8.1 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 2.4 3.7 4.8 6.6 7.8 11 12.5 17.5 25 31 48 61 75 88 105 140 170 205 245 50% overload current (A) 3.6 5.6 7.2 9.9 11.7 16.5 18.8 26.3 37.5 46.5 72 92 113 132 158 210 255 308 368

Low (+40C) AC drive type Rated continuous current I L (A) 3.7 4.8 6.6 7.8 11 12.5 17.5 25 31 48 61 75 88 114 140 170 205 261 300 10% overload current (A) 4.1 5.3 7.3 8.6 12.1 13.8 19.3 27.5 34.1 52.8 67.1 83 97 125 154 187 226 287 330

NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP

0003 0004 0007 0008 0011 0012 0017 0025 0031 0048 0061 0075 0088 0114 0140 0170 0205 0261 0300

2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSF 2 A 2 H 0 SSF

Mains voltage 380500 V, 50/60 Hz, 3

Loadability Motor shaft power 400 V supply Maximum current I S 4.4 6.2 8.6 10.8 14 18 24 32 46 62 76 92 122 144 174 210 280 336 349 444 10% overload P (kW) 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 50% overload P (kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 Frame size Dimensions and weight W*H*D (mm)/ kg 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 144*391*214/ 8.1 144*391*214/ 8.1 144*391*214/ 8.1 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 2.2 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 87 105 140 170 205 245 50% overload current (A) 3.3 5 6.5 8.4 11.4 13.5 18 24 35 47 57 69 92 108 131 158 210 255 308 368

Low (+40C) AC drive type Rated continuous current I L (A) 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 87 105 140 170 205 261 300 10% overload current (A) 3.6 4.7 6.2 8.4 9.9 13.2 17.6 25.3 34 42 51 67 79 96 116 154 187 226 287 330

NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP

0003 0004 0005 0007 0009 0012 0016 0022 0031 0038 0045 0061 0072 0087 0105 0140 0168 0205

5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS

FR4 FR4 FR4 FR4 FR4 FR4 FR5 FR5 FR5 FR6 FR6 FR6 FR7 FR7 FR7 FR8 FR8 FR8 FR9 FR9

NXP 0261 5 A 2 H 0 SSF NXP 0300 5 A 2 H 0 SSF

wall-mounted vacon nxp


Mains voltage 500690 V, 50/60 Hz, 3

Loadability Motor shaft power 690 V supply Maximum current I S 6.4 9.0 11 15 20 27 36 44 54 68 82 104 124 160 200 213 245 289 10% overload P (kW) 3 4 5.5 7.5 11 15 18.5 22 30 37.5 45 55 75 90 110 132 160 200 50% overload P (kW) 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37.5 45 55 75 90 110 132 160 Frame size Dimensions and weight W*H*D (mm)/ kg 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 3.2 4.5 5.5 7.5 10 13.5 18 22 27 34 41 52 62 80 100 125 144 170 50% overload current (A) 4.8 6.8 8.3 11.3 15 20.3 27 33 41 51 62 78 93 120 150 188 216 255

Low (+40C) AC drive type Rated continuous current I L (A) 4.5 5.5 7.5 10 13.5 18 22 27 34 41 52 62 80 100 125 144 170 208 10% overload current (A) 5 6.1 8.3 11 14.9 19.8 24.2 29.7 37 45 57 68 88 110 138 158 187 229

NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP

0004 0005 0007 0010 0013 0018 0022 0027 0034 0041 0052 0062 0080 0100 0125 0144 0170 0208

6 A 2 L 0 SSS 6 A 2 L 0SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF

FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR7 FR7 FR8 FR8 FR8 FR9 FR9 FR9 FR9

standalone vacon nxp


High-power Vacon NXP drives are also available in a compact standalone IP21 or IP54 enclosure. These units are designed for use in applications where the drive has to be compact and easy to install.
The Vacon NXP standalone drives are fully enclosed at the factory and are ready for immediate installation. The drive has integrated fuses as standard and no extra protections are required by the drive. It is also possible to equip the drive with an optional integrated load switch, which further simplies handling in the eld.

Mains voltage 380500 V, 50/60 Hz, 3

Loadability Motor shaft power 400 V supply Maximum current I S 10% overload P (kW) 200 250 250 315 355 400 50% overload P (kW) 160 200 250 250 315 355 Frame size Dimensions and weight W*H*D (mm)/ kg 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 794*2020*602/ 470 794*2020*602/ 470 794*2020*602/ 470 High (+40C) Rated continuous current I H (A) 300 385 460 520 590 650 50% overload current (A) 450 578 690 780 885 975

Low (+40C) AC drive type Rated continuous current I L (A) 385 460 520 590 650 730 10% overload current (A) 424 506 572 649 715 803

NXP 0385 5 A 2 L 0 SSA NXP 0460 5 A 2 L 0 SSA NXP 0520 5 A 2 L 0 SSA NXP 0590 5 A 2 L 0 SSA NXP 0650 5 A 2 L 0 SSA NXP 0730 5 A 2 L 0 SSA

540 693 828 936 1062 1170

FR10 FR10 FR10 FR11 FR11 FR11

Mains voltage 500690 V, 50/60 Hz, 3

Loadability Motor shaft power 690 V supply Maximum current I S 10% overload P (kW) 250 315 355 400 450 500 560 50% overload P (kW) 200 250 315 315 355 450 500 Frame size Dimensions and weight W*H*D (mm)/ kg 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 794*2020*602/ 400 794*2020*602/ 400 794*2020*602/ 470 High (+40C) Rated continuous current I H (A) 208 261 325 325 385 460 502 50% overload current (A) 312 392 488 488 578 690 753

Low (+40C) AC drive type Rated continuous current I L (A) 261 325 385 416 460 502 590 10% overload current (A) 287 358 424 458 506 552 649

NXP 0261 6 A 2 L 0 SSA NXP 0325 6 A 2 L 0 SSA NXP 0385 6 A 2 L 0 SSA NXP 0416 6 A 2 L 0 SSA # NXP 0460 6 A 2 L 0 SSA NXP 0502 6 A 2 L 0 SSA NXP 0590 6 A 2 L 0 SSA #
# max. ambient temperature of +35C

375 470 585 585 693 828 904

FR10 FR10 FR10 FR10 FR11 FR11 FR11

hardware configurations
FUNCTION IP21 IP54 (FR10 only) Integrated fuses Load switch EMC ltering L EMC ltering T Brake chopper (cabling top entry) AVAILABILITY Standard Optional Standard Optional Standard Optional Optional (H: +122 mm)

ip00 vacon nxp modules


The Vacon NXP high-power IP00 drive modules are intended for installation in a separate enclosure. Thanks to the robust, square-shaped design of the module, enclosure design is easy and straightforward.
Mains voltage 380500 V, 50/60 Hz, 3

Loadability Motor shaft power 400 V supply Maximum current I S 10% overload P (kW) 200 250 250 315 355 400 450 500 560 50% overload P (kW) 160 200 250 250 315 355 400 450 500 Frame size Module W*H*D (mm)/ kg Chokes W*H*D (mm)/ kg High (+40C) Rated continuous current I H (A) 300 385 460 520 590 650 730 820 920 50% overload current (A) 450 578 690 780 885 975 1095 1230 1380

Low (+40C) AC drive type Rated continuous current I L (A) 385 460 520 590 650 730 820 920 1030 10% overload current (A) 424 506 572 649 715 803 902 1012 1133

NXP 0385 5 A 0 N 0 SSA NXP 0460 5 A 0 N 0 SSA NXP 0520 5 A 0 N 0 SSA NXP 0590 5 A 0 N 0 SSA NXP 0650 5 A 0 N 0 SSA NXP 0730 5 A 0 N 0 SSA NXP 0820 5 A 0 N 0 SSA NXP 0920 5 A 0 N 0 SSA NXP 1030 5 A 0 N 0 SSA

540 693 828 936 1062 1170 1314 1476 1656

FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12

500*1165*506/ 120

350*383*262/ 84 1)

500*1165*506/ 120 497*399*244/ 115 1) 500*1165*506/ 120 497*399*244/ 115 1) 709*1206*506/ 210 709*1206*506/ 210 709*1206*506/ 210 2x(350*383*262/ 84) 2x(350*383*262/ 84) 2x(350*383*262/ 84)

2x(500*1165*506/ 120) 2x(497*399*244/ 115) 2x(500*1165*506/ 120) 2x(497*399*244/ 115) 2x(500*1165*506/ 120) 2x(497*399*244/ 115)

1) 12-pulse units, 2x(354*319*230/ 53 kg)

Mains voltage 500690 V, 50/60 Hz, 3

Loadability Motor shaft power 690 V supply Maximum current I S 10% overload P (kW) 250 315 355 400 450 500 560 630 710 800 50% overload P (kW) 200 250 315 315 355 450 500 560 630 630 Frame size Module W*H*D (mm)/ kg Chokes W*H*D (mm)/ kg High (+40C) Rated continuous current I H (A) 208 261 325 325 385 460 502 590 650 650 50% overload current (A) 312 392 488 488 578 690 753 885 975 975

Low (+40C) AC drive type Rated continuous current I L (A) 261 325 385 416 460 502
#

10% overload current (A) 287 358 424 458 506 552 649 715 825 902

NXP 0261 6 A 0 N 0 SSA NXP 0325 6 A 0 N 0 SSA NXP 0385 6 A 0 N 0 SSA NXP 0416 6 A 0 N 0 SSA # NXP 0460 6 A 0 N 0 SSA NXP 0502 6 A 0 N 0 SSA NXP 0590 6 A 0 N 0 SSA NXP 0650 6 A 0 N 0 SSA NXP 0750 6 A 0 N 0 SSA NXP 0820 6 A 0 N 0 SSA #

375 470 585 585 693 828 904 1062 1170 1170

FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12

500*1165*506/ 120 354*319*230/ 53 1) 500*1165*506/ 120 350*383*262/ 84 1) 500*1165*506/ 120 350*383*262/ 84 1) 500*1165*506/ 120 350*383*262/ 84 1) 709*1206*506/ 210 497*399*244/ 115 2) 709*1206*506/ 210 497*399*244/ 115 2) 709*1206*506/ 210 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84)

590 650 750 820

# max. ambient temperature of +35C

1) 12-pulse units, 2x(354*319*230/ 53 kg)

2) 12-pulse units, 2x(350*383*262/ 84 kg)

Bigger units are available on request.

hardware configurations
FUNCTION Integrated control unit External control unit Integrated brake chopper 6-pulse supply 12-pulse supply EMC ltering N EMC ltering T AVAILABILITY Standard Optional Optional Standard Optional Standard Optional

vacon nxc, compact and flexible


The Vacon NXC cabinet drive is compact and well tested, fully utilizing the exibility of the Vacon NXP drive. The Vacon NXC is designed to meet the most demanding requirements for exibility, robustness, compactness and service-friendliness. It is a safe choice for any application.

Easy ordering The Vacon NXC contains the AC drive itself and optional items such as main switch, contactor, control options and output ltering in one compact unit which is easy to install and service. Ordering is made easy by integrating the Vacon NXC enclosure options into the typecode, to which they are appended with + codes.

User-friendly In the Vacon NXC, the control unit is mounted in a separate compartment at an easily accessible height together with all control options. Ample space around the power terminals allows easy installation and connection of power cables. Bottom plates and earthing clamps for 360-degree earthing of motor cable shields are provided as standard.

Well tested Vacon NXC drives are the result of more than 20 years of experience in enclosure design. It is a well tested and proven solution. The good thermal handling of the enclosure guarantees a long lifetime for the AC drive and trouble-free operation even in the most demanding environments. Approved EMC solutions ensure reliable operation of the converter without disturbing other electrical equipment.

Service-friendly The Vacon NXC enclosures are designed to fully utilize the new and innovative installation features of the high-power Vacon NXP. The Vacon NXP power units are mounted on rails which are extendable with a pull-out jig. The jig can be used for pulling the power unit out of the enclosure for service.

vacon nxp/nxc type designation code


NXC 0520 5 A 2 L 0 SSF A1A2000000 + IFD
NXC options, see table below Option PCBs; each slot is represented by two characters where: Ax = basic I/O PCBs, Bx = expander I/O PCBs Cx = eldbus PCBs, Dx = special PCBs Control S = standard FR4-FR8 V = as S, but varnished PCBs F = standard FR9 and NXC G = as F, but varnished PCBs A = standard NXP FR10-FR12 B = as A, but varnished PCBs N = standard IP00 FR10 and NXC O = as N, but varnished PCBs with IP54 control unit enclosure Cooling S = standard air-cooled, T = through-hole mounting FR4-FR9 Supply S = 6-pulse, T = 12-pulse, O = 6-pulse + load switch (standalone) R = Regenerative low-harmonic (AFE) Brake chopper 0 = no brake chopper 1 = integrated brake chopper EMC emission level EN61800-3 C = 1st env., unrestricted distribution T = for IT networks H = 1st env., restricted distribution N = enclosure required (FR10-FR14) L = 2nd environment Enclosure class 0 = IP00 (module only) 2 = IP21 (NEMA 1) 5 = IP54 (NEMA 12) Control keypad A = standard alphanumeric B = no local keypad F = dummy keypad G = graphic display Nominal mains voltage 5 = 380-500 VAC, 6 = 525-690 VAC, 2 = 208-240 VAC Nominal current voltage 0520 = 520 A Product range NXP = wall-mounted / standalone / module NXC = cabinet

vacon nxc options


Control terminal options (T group) +TIO +TID +TUP +ILS +IFD +ICB +ICO +IFU +MDC +OCM +ODU +OSI +PTR +PES +PED +PAP +PIF +G40 +G60 +G80 +GPL +CIT +COT Basic I/O wired to external terminals Basic I/O wired to external terminals + additional terminals Terminals for 230 VAC control voltage Load switch Switch fuse and fuses Circuit breaker (MCCB) Input contactor Input fuses Terminals in cabinet for DC / brake chopper Common mode lters du/dt lter Sine wave lter External thermistor relay Emergency stop (cat 0) Emergency stop (cat 1) Arc protection Insulation fault sensor 400 mm empty cabinet 600 mm empty cabinet 800 mm empty cabinet 100 mm base Input (mains) cabling from top Output (motor) cabling from top Auxiliary equipment (A group) +AMF +AMH +AMB +AMO +ACH +ACL +ACR +AAI +AAA +AAC +AT1 +AT2 +AT3 +AT4 +ADC +ACS +DLV +DLD +DLF +DLR +DCO +DRO +DEP +DRP +DAM +DAR +DCM +DVM Motor fan control Motor heater feeder Mechanical brake control Motor operator for +ICB Cabinet heater Cabinet light Control relay Analog signal isolator Auxiliary contact (control voltage devices) Auxiliary contact (input device) Auxiliary voltage transformer 200 VA Auxiliary voltage transformer 750 VA Auxiliary voltage transformer 2500 VA Auxiliary voltage transformer 4000 VA Power supply 24 VDC 2.5 A 230 VAC customer socket Pilot light (Control voltage on) Pilot light (DO1) Pilot light (FLT) Pilot light (RUN) Main contactor operation switch Local / Remote operation switch Emergency stop push-button Reset push-button Analog meter (AO1) Potentiometer for reference Analog meter + current trafo Analog voltage meter with selection switch

Input device options (I group)

Main circuit options (M group) Output lter options (O group)

Protection devices (P group)

Door-mounted options (D group)

General options (G group)

Cabling options (C group)

vacon nxc, 6-pulse supply


Mains voltage 380500 V, 50/60 Hz
Loadability Low (+40C) AC drive type Rated continuous current I L (A) 261 300 385 460 520 590 650 730 820 920 1030 1150 1300 1450 1770 2150 10% overload current (A) 287 330 424 506 572 649 715 803 902 1012 1133 1265 1430 1595 1947 2365 High (+40C) Rated continuous current I H (A) 205 245 300 385 460 520 590 650 730 820 920 1030 1150 1300 1600 1940 50% overload current (A) 308 368 450 578 690 780 885 975 1095 1230 1380 1545 1725 1950 2400 2910 Maximum current I S Motor shaft power 400 V supply 10% overload P (kW) 132 160 200 250 250 315 355 400 450 500 560 630 710 800 1000 1200 50% overload P (kW) 110 132 160 200 250 250 315 355 400 450 500 560 630 710 900 1100 Frame size Dimensions and weight W*H*D (mm)/ kg 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 403 606*2275*605/ 403 806*2275*605/ 577 806*2275*605/ 577 806*2275*605 / 577 1206*2275*605/ 810 1206*2275*605/ 810 1206*2275*605/ 810 1406*2275*605/ 1000 1606*2275*605/ 1100 1606*2275*605/ 1100 2806*2275*605/ 2440 2806*2275*605 / 2500

NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC

0261 0300 0385 0460 0520 0590 0650 0730 0820 0920 1030 1150 1300 1450 1770 2150

5 A 2 H 0 SSF 5 A 2 H 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF

349 444 540 693 828 936 1062 1170 1314 1476 1656 1854 2070 2340 2880 3492

FR9 FR9 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14

Mains voltage 500690 V, 50/60 Hz


Loadability Low (+40C) AC drive type Rated continuous current I L (A) 125 144 170 208 261 325 385 416 460 502 590 650 750 820 920 1030 1180 1500 1900 2250 10% overload current (A) 138 158 187 229 287 358 424 458 506 552 649 715 825 902 1012 1133 1298 1650 2090 2475 High (+40C) Rated continuous current I H (A) 100 125 144 170 208 261 325 325 385 460 502 590 650 650 820 920 1030 1300 1500 1900 50% overload current (A) 150 188 216 255 312 392 488 488 578 690 753 885 975 975 1230 1380 1463 1950 2250 2782 Maximum current I S Motor shaft power 690 V supply 10% overload P (kW) 110 132 160 200 250 315 355 400 450 500 560 630 710 800 900 1000 1150 1500 1800 2000 50% overload P (kW) 90 110 132 160 200 250 315 315 355 450 500 560 630 630 800 900 1000 1300 1500 1800 Frame size Dimensions and weight W*H*D (mm)/ kg 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 341 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 371 806*2275*605/ 524 806*2275*605/ 524 806*2275*605/ 577 1206*2275*605/ 745 1206*2275*605/ 745 1206*2275*605/ 745 1406*2275*605/ 1000 1406*2275*605/ 1000 1406*2275*605/ 1000 2406*2275*605/ 2350 2806*2275*605/ 2440 2806*2275*605/ 2500

NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC

0125 0144 0170 0208 0261 0325 0385 0416 0460 0502 0590 0650 0750 0820 0920 1030 1180 1500 1900 2250

6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF#

200 213 245 289 375 470 585 585 693 828 904 1062 1170 1170 1410 1755 1755 2340 2700 3335

FR9 FR9 FR9 FR9 FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14 FR14

# max. ambient temperature of +35C

hardware configurations
6-pulse Enclosure EMC Brake chopper IP54 L T H 380-500 V IP21 FR9 S O (H: +130) S O FR10 S O (H: +130) S O FR11 S O (H: +130)* S O FR12 S O (H: +130) S O FR13 S O (H: +170) S O FR14 S O (H: +170) S O 500-690 V FR9 S O (H: +130) S O FR10 S O (H: +130) S O FR11 S O (H: +130)* S O FR12 S O (H: +130) S O FR13 S O (H: +170) S O FR14 S O (H: +170) S O O O O O
1 1

Cabling Top Bottom S S S S S S S S S S S S +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) +IFU O O O O O O O O +ILS O O O O O O O O -

Input device Fuses Load Sw. Sw.-fuse Contactor MCCB Cmn Mode +IFD O O O O S O O O O S +ICO O O O O O O O O +ICB O O O O O S O O O O O S +OCM O O O O O O O O O O O O

Output lters du/dt +ODU O (W: +400) O (W: +400) O (W: +400) O (W: +400) O S O (W: +400) O (W: +400) O (W: +400) O (W: +400) O S Sine wave +OSI O(W: +600) O(W: +600) O(W: +600-800) O(W: +1200) O(W: +800) O(W: +1600) O(W: +600) O(W: +600) O(W: +600) O(W: +1200) O(W: +800) O(W: +1600)

O O O O
1 1

S = Standard
10

O = Optional

1)

(W: +400) = Contact factory

*) NXC07305 and NXC05906, H: +170 mm

vacon nxc, 12-pulse supply


Mains voltage 380500 V, 50/60 Hz
Loadability Low (+40C) AC drive type Rated continuous current I L (A) 385 460 520 590 650 730 820 920 1030 1150 1300 1450 1770 2150 10% overload current (A) 424 506 572 649 715 803 902 1012 1133 1265 1430 1595 1947 2365 High (+40C) Rated continuous current I H (A) 300 385 460 520 590 650 730 820 920 1030 1150 1300 1600 1940 50% overload current (A) 450 578 690 780 885 975 1095 1230 1380 1545 1725 1950 2400 2910 Maximum current I S Motor shaft power 400 V supply 10% overload P (kW) 200 250 250 315 355 400 450 500 560 630 710 800 1000 1200 50% overload P (kW) 160 200 250 250 315 355 400 450 500 560 630 710 900 1100 Frame size Dimensions and weight W*H*D (mm)/ kg 606*2275*605/ 371 606*2275*605/ 403 606*2275*605/ 403 806*2275*605/ 577 806*2275*605/ 577 806*2275*605/ 577 1206*2275*605/ 810 1206*2275*605/ 810 1206*2275*605/ 810 1406*2275*605/ 1000 2006*2275*605/ 1100 2006*2275*605/ 1100 2806*2275*605/ 2440 2806*2275*605/ 2500

NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC

0385 0460 0520 0590 0650 0730 0820 0920 1030 1150 1300 1450 1770 2150

5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF

540 693 828 936 1062 1170 1314 1476 1656 1854 2070 2340 2880 3492

FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14

Mains voltage 500690 V, 50/60 Hz


Loadability Low (+40C) AC drive type Rated continuous current I L (A) 261 325 385 416 460 502 590 650 750 820 920 1030 1180 1500 1900 2250 10% overload current (A) 287 358 424 458 506 552 649 715 825 902 1012 1133 1298 1650 2090 2475 High (+40C) Rated continuous current I H (A) 208 261 325 325 385 460 502 590 650 650 820 920 1030 1300 1500 1900 50% overload current (A) 312 392 488 488 578 690 753 885 975 975 1230 1380 1463 1950 2250 2782 Maximum current I S Motor shaft power 690 V supply 10% overload P (kW) 250 315 355 400 450 500 560 630 710 800 900 1000 1150 1500 1800 2000 50% overload P (kW) 200 250 315 315 355 450 500 560 630 630 800 900 1000 1300 1500 1800 Frame size Dimensions and weight W*H*D (mm)/ kg 606*2275*605/ 341 606*2275*605/ 371 606*2275*605/ 371 606*2275*605/ 403 806*2275*605/ 524 806*2275*605/ 524 806*2275*605/ 577 1206*2275*605/ 745 1206*2275*605/ 745 1206*2275*605/ 745 1406*2275*605/ 1000 1406*2275*605/ 1000 1406*2275*605/ 1000 2806*2275*605/ 2440 2806*2275*605/ 2440 2806*2275*605/ 2500

NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC

0261 0325 0385 0416 0460 0502 0590 0650 0750 0820 0920 1030 1180 1500 1900 2250

6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF#

375 470 585 585 693 828 904 1062 1170 1170 1410 1755 1755 2340 2700 3335

FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14 FR14

# max. ambient temperature of +35C

hardware configurations
12-pulse Enclosure L S S S S S EMC T H O O O O O Brake chopper IP54 380-500 V IP21 FR10 S O (H: +130) FR11 S O (H: +130)* FR12 S O (H: +130) FR13 S O (H: +170) FR14 S O (H: +170) 500-690 V FR10 S O (H: +130) FR11 S O (H: +130)* FR12 S O (H: +130) FR13 S O (H: +170) FR14 S O (H: +170) O O
1 1

Cabling Top Bottom S S S S S S S S S S +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +800) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +800) +IFU O O O O O O +ILS O O O O -

Input device Fuses Load Sw. Sw.-fuse Contactor MCCB Cmn Mode +IFD O O O O +ICO O O O O +ICB O O O S S O O O S S +OCM O O O O O O O O O O

Output lters du/dt +ODU O (W: +400) O (W: +400) O (W: +400) O S O (W: +400) O (W: +400) O (W: +400) O S Sine wave +OSI O(W: +600) O(W: +600-800) O(W: +1200) O(W: +800) O(W: +1600) O(W: +600) O(W: +600) O(W: +1200) O(W: +800) O(W: +1600)

S O S O S O S O S O

O O
1 1

S = Standard

O = Optional

1)

(W: +400) = Contact factory

*) NXC07305 and NXC05906, H: +170 mm

11

vacon nxc, regenerative low-harmonic drive


The Vacon NXC regenerative low-harmonic brings savings in applications in which either regenerative function or low-harmonics are required.

The Vacon NXC regenerative and low-harmonic cabinet drives are a perfect choice for applications where low harmonics are required or where energy is fed back to the mains. Clean power saves costs The regenerative low-harmonic cabinet drive offers an excellent total solution to meet even the most demanding power quality requirements. The drive complies with the IEEE-519, G5/4 harmonic standards, when correctly installed. The low current THDi reduces supply currents and allows supply transformers, protection devices and power cables to be smaller. It brings savings for new and retrofit projects because there is no need to invest in expensive 12- or 18-pulse transformers when new or old existing 6-pulse transformers can be used. Regenerative functionality saves energy The regenerative function makes it possible to feed energy back to the mains in energy generation applications or to improve the efficiency of the system when the braking power can be fed back to the mains. An additional advantage is simplified installation work and space savings when no brake resistors are needed. Power factor control improves the supply The power factor of the active supply unit can be set in a wide range that makes it possible to minimize the required reactive power of the system. Main features Clean power with total current harmonics less than 5% Regenerative function brings savings Power factor control Compact solution with a wide range of standard options available makes it easy to configure the drive

12

vacon nxc options


Vacon NXC options give greater exibility and make it easy to extend the range of functions. Options are available in different categories and can be combined to meet almost any requirements.

Auxiliary equipment (A group) +AMF Motor fan control +AMH Motor heater feeder +AMB Mechanical brake control +ACH Cabinet heater +ACL Cabinet light +ACR Control relay +AAI Analog signal isolator +AAA Aux. contact (ctrl voltage) +AAC Aux. contact (input device) +AT3 Aux. voltage transformer 2500 VA +AT4 Aux. voltage transformer 4000 VA +ADS 230 VAC customer socket Control terminal options (T group) +TIO Basic I/O wired to external terminals +TID Basic I/O wired to external terminals + additional terminals

Door-mounted options (D group) +DLV Pilot light (control voltage on) +DLD Pilot light (DO1) +DLF Pilot light (FLT) +DLR Pilot light (RUN) +DEP Emergency stop push-button +DRP Reset push-button +DAM Analog meter (AO1) +DAR Potentiometer for reference +DCM Analog meter current trafo +DVM Analog voltage meter switch

Output lter options (O group) +OCM Common mode lters +ODU du/dt lter +OSI Sine wave lter Protection devices (P group) +PTR External thermistor relay +PES Emergency stop (cat 0) +PED Emergency stop (cat 1) +PAP Arc protection +PIF Insulation fault sensor

General options (G group) +G40 400 mm empty cabinet +G60 600 mm empty cabinet +G80 800 mm empty cabinet +GPL 100 mm base

Cabling options (C group) +CIT Input (mains) cabling from top +COT Output (motor) cabling from top

current harmonic mitigation


6-pulse rectier with choke Cost-effective transformer and simple power cabling with high current distortion. Oversizing of transformers needed due to high THDi. Direction of power Current distortion (THDi) > 35 %

Direction of power 12-pulse rectier with choke Higher transformer and power cabling cost. Low current distortion on primary side of transformer.

Current distortion (THDi) > 12 %

Direction of power Active front-end with LCL lter Cost effective transformer and power cabling with very low current distortion. No oversizing of transformer needed.

Current distortion (THDi) < 5 %

13

vacon nxc, regenerative low-harmonic drive


Mains voltage 380500 V, 50/60 Hz, 3~
Loadability Low (+40C) Low-harmonic regenerative drive type Rated continuous current I L (A) 261 300 385 460 520 650 730 820 920 1030 1150 1300 1450 1770 2150 2700 10% overload current (A) 287 330 424 506 572 715 803 902 1012 1133 1265 1430 1595 1947 2365 2970 High (+40C) Rated continuous current I H (A) 205 245 300 385 460 590 650 730 820 920 1030 1150 1300 1600 1940 2300 50% overload current (A) 308 368 450 578 690 885 975 1095 1230 1380 1545 1725 1950 2400 2910 3278 Maximum current IS (A) 349 444 540 693 828 1062 1170 1314 1476 1656 1854 2070 2340 2880 3492 3933 Motor shaft power 400 V supply 10% overload P (kW) 132 160 200 250 250 355 400 450 500 560 630 710 800 1000 1200 1500 50% overload P (kW) 110 132 160 200 250 315 355 400 450 500 560 630 710 900 1100 1200 Frame size Dimensions and weight W*H*D (mm)/ kg 1006x2275x605/680 1006x2275x605/680 1006x2275x605/700 1006x2275x605/700 1006x2275x605/700 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2206x2275x605/1950 2206x2275x605/1950 2206x2275x605/1950 4406x2275x605/3900 4406x2275x605/3900 4406x2275x605/3900

NXC 0261 5 A 2 L 0 RSF NXC 0300 5 A 2 L 0 RSF NXC 0385 5 A 2 L 0 RSF NXC 0460 5 A 2 L 0 RSF NXC 0520 5 A 2 L 0 RSF NXC 0650 5 A 2 L 0 RSF NXC 0730 5 A 2 L 0 RSF NXC 0820 5 A 2 L 0 RSF NXC 0920 5 A 2 L 0 RSF NXC 1030 5 A 2 L 0 RSF NXC 1150 5 A 2 L 0 RSF NXC 1300 5 A 2 L 0 RSF NXC 1450 5 A 2 L 0 RSF NXC 1770 5 A 2 L 0 RSF NXC 2150 5 A 2 L 0 RSF NXC 2700 5 A 2 L 0 RSF

FI9 + FI9 FI9 + FI9 FI10 + FI10 FI10 + FI10 FI10 + FI10 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 FI13 + FI13 FI13 + FI13 FI13 + FI13 2xFI13 + FI14 2xFI13 + FI14 2xFI13 + FI14

Mains voltage 525690 V, 50/60 Hz, 3~


Loadability Low (+40C) Low-harmonic regenerative drive type Rated continuous current I L (A) 125 144 170 208 261 325 385 416 460 502 590 650 750 820 920 1030 1180 1500 1900 2250 10% overload current (A) 138 158 187 229 287 358 424 416 506 552 649 715 825 902 1012 1133 1298 1650 2090 2475 High (+40C) Rated continuous current I H (A) 100 125 144 170 208 261 325 325 385 460 502 590 650 650 820 920 1030 1300 1500 1900 50% overload current (A) 150 188 216 255 312 392 488 488 578 690 753 885 975 975 1230 1380 1463 1950 2250 2782 Maximum current IS (A) 200 213 245 289 375 470 585 585 693 828 904 1062 1170 1170 1476 1656 1755 2340 2700 3335 Motor shaft power 690 V supply 10% overload P (kW) 110 132 160 200 250 315 355 400 450 500 560 630 710 800 900 1000 1150 1500 1800 2000 50% overload P (kW) 90 110 132 160 200 250 315 315 355 450 500 560 630 630 800 900 1000 1300 1500 1800 Frame size Dimensions and weight W*H*D (mm)/ kg 1006x2275x605/680 1006x2275x605/680 1006x2275x605/680 1006x2275x605/680 1006x2275x605/700 1006x2275x605/700 1006x2275x605/700 1006x2275x605/700 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2006x2275x605/1400 2206x2275x605/1950 2206x2275x605/1950 2206x2275x605/1950 4406x2275x605/3900 4406x2275x605/3900 4406x2275x605/3900

NXC 0125 6 A 2 L 0 RSF NXC 0144 6 A 2 L 0 RSF NXC 0170 6 A 2 L 0 RSF NXC 0208 6 A 2 L 0 RSF# NXC 0261 6 A 2 L 0 RSF NXC 0325 6 A 2 L 0 RSF NXC 0385 6 A 2 L 0 RSF NXC 0416 6 A 2 L 0 RSF# NXC 0460 6 A 2 L 0 RSF NXC 0502 6 A 2 L 0 RSF NXC 0590 6 A 2 L 0 RSF NXC 0650 6 A 2 L 0 RSF NXC 0750 6 A 2 L 0 RSF NXC 0820 6 A 2 L 0 RSF# NXC 0920 6 A 2 L 0 RSF NXC 1030 6 A 2 L 0 RSF NXC 1180 6 A 2 L 0 RSF# NXC 1500 6 A 2 L 0 RSF NXC 1900 6 A 2 L 0 RSF NXC 2250 6 A 2 L 0 RSF#

FI9 + FI9 FI9 + FI9 FI9 + FI9 FI9 + FI9 FI10 + FI10 FI10 + FI10 FI10 + FI10 FI10 + FI10 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 FI13 + FI13 FI13 + FI13 FI13 + FI13 2xFI13 + FI14 2xFI13 + FI14 2xFI13 + FI14

# max. ambient temperature of 35C

hardware configurations
Active supply unit 380-500 V FI9+FI9 FI10+FI10 2 x FI10+FI12 FI13+FI13 2 x FI13+FI14 525-690 V FI9+FI9 FI10+FI10 2 x FI10+FI12 FI13+FI13 2 x FI13+FI14 1) Contact factory S S S S S O (H: +130) O (H: +130) O (H: +130) O (H: +170) O (H: +170) S S S S S O O O O O 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) S S S S S O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) S S S S S O O O O O O (W:+400) O (W: +600) O (W:+400) O (W: +600) O (W:+400) O (W: +1200) O S O (W: +800) O (W: +1600) Enclosure IP21 S S S S S IP54 O (H: +130) O (H: +130) O (H: +130) O (H: +170) O (H: +170) L S S S S S EMC T O O O O O 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) Brake chopper Cabling Bottom S S S S S Top +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) Input device Output lters Load Sw. & Cmn Mode du/dt Sinewave MCCB +OCM +ODU +OSI +ILS & +ICB S S S S S O O O O O O (W:+400) O (W: +600) O (W:+400) O (W: +600) O (W:+400) O (W: +1200) O S O (W: +800) O (W: +1600)

14

S = Standard

O = Optional

vacon drivesynch
The Vacon DriveSynch is a new, innovative control concept for running standard drives in parallel to control high-power AC motors. This concept suits high-power single or multiple winding motors typically above 1 MW.

High-power AC drives up to 5 MW can be built using standard drive components with the following benets:
System is modular and easy to extend High total power can be obtained combining smaller drives The redundancy of the system is higher than in a conventional drive because each unit can be run independently The small size of the individual drive makes it easy to maintain and service Identical individual units reduce the required amount of spare parts and costs No special skills are required for engineering, installation, commissioning and maintenance of high-power drives as they are made from standard low-power modules Du/dt filter at the output of each individual unit ensures load balancing Can also run multiple winding motors with a phase shift between the windings

Fiber Optic Link

Fiber Optic Link

Mains voltage 380500 V, 50/60 Hz


Loadability Low (+40C) AC drive type Rated continuous current I L (A) 2150 2470 2755 3278 3705 4133 10% overload current (A) 2365 2717 3031 3605 4076 4546 High (+40C) Rated continuous current I H (A) 1940 2185 2470 2936 3278 3705 50% overload current (A) 2910 3278 3705 4403 4916 5558 Maximum current I S (A) 3492 3933 4446 5284 5900 6669 Motor shaft power 400 V supply 10% overload P (kW) 1200 1350 1500 1800 2000 2250 50% overload P (kW) 1100 1100 1350 1500 1800 2000 Frame size Dimensions and weight W*H*D (mm)/ kg 2x(1406*2275*605/1250) 2x(1606*2275*605/1350) 2x(1606*2275*605/1350) 3x(1406*2275*605/1250) 3x(1606*2275*605/1350) 3x(1606*2275*605/1350)

2 x NXC 2 x NXC 2 x NXC 3 x NXC 3 x NXC 3 x NXC

1150 1300 1450 1150 1300 1450

5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF

2 x FR13 2 x FR13 2 x FR13 3 x FR13 3 x FR13 3 x FR13

Mains voltage 500690 V, 50/60 Hz


Loadability Low (+40C) AC drive type Rated continuous current I L (A) 1748 1900 2250 2622 2936 3363 10% overload current (A) 1923 2090 2475 2884 3229 3699 High (+40C) Rated continuous current I H (A) 1558 1500 1900 2337 2622 2936 50% overload current (A) 2337 2250 2782 3506 3933 4170 Maximum current I S (A) 2679 2700 3335 4019 5002 5002 Motor shaft power 690 V supply 10% overload P (kW) 1700 1800 2000 2500 2800 3200 50% overload P (kW) 1400 1500 1800 2000 2500 2800 Frame size Dimensions and weight W*H*D (mm)/ kg 2x(1406*2275*605/1250) 2x(1406*2275*605/1250) 2x(1406*2275*605/1250) 3x(1406*2275*605/1250) 3x(1406*2275*605/1250) 3x(1406*2275*605/1250)

2 x NXC 2 x NXC 2 x NXC 3 x NXC 3 x NXC 3 x NXC

0920 1030 1180 0920 1030 1180

6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF#

2 x FR13 2 x FR13 2 x FR13 3 x FR13 3 x FR13 3 x FR13

# max. ambient temperature of 35C

15

vacon nxp control


The Vacon NXP offers a high-performance control platform for all demanding drive applications. There are ve slots (A, B, C, D and E) for I/O boards, and a suitable board can be selected for each slot (see table below). An external +24 V supply option enables communication with the control unit even if the main supply is switched off (e.g. for eldbus communication and parameter setting). The Vacon NXP supports both induction motors and permanent magnet motors in open and closed loop control modes. The Vacon NXP also supports special motors such as highspeed motors. For a closed loop control encoder, feedback from an incremental pulse encoder is normally used. It is also possible to use absolute encoders, since the Vacon NXP is available with EnDat, SSI and resolver interfaces. Fast drive-to-drive communication is possible using Vacons fast SystemBus ber optic communication.

option boards
Type Card slot
DI DO DI AI (mA/ V/V) AI (mA) isolated AO (mA/V) AO (mA) RO RO

I / O signal
+10Vref Therm +24V/ pt100 42-240 EXT +24V VAC input (10...24V) (RS422) DI/DO DI/DO DO (NO/ (NO)

A B C D E Basic I/O cards (OPT-A) OPT-A1 OPT-A2 OPT-A3 OPT-A4 OPT-A5 OPT-A7 OPT-A8 OPT-A9 OPT-AE OPT-AF OPT-AK OPT-B1 OPT-B2 OPT-B4 OPT-B5 OPT-B8 OPT-B9 OPT-BB OPT-BC OPT-BE OPT-C2 OPT-C3 OPT-C4 OPT-C5 OPT-C6 OPT-C7 OPT-C8 OPT-CF OPT-CG OPT-CI OPT-CJ OPT-D1 OPT-D2 OPT-D3 OPT-D6 OPT-D7 6 1

isolated NC)

1Vp-p

DI

Resolver Out +5V/ +15V/ +24V

Out +15V/ +24V

Out +5V/ +12V/ +15V

Note

1 2 1 1

1 1

2 2 6 1 6 1 2 2 2 2 1 1 2 1 1 1 2 2

3/0 3/0 6/2

1 1 1
2 enc. input + 1 enc. output 1) 2.5 mm 2 terminals

3/0 3 6 1 1 2 3 1 3 5 0/2 3/3 2 1 1 1 1 1

1 1

DO = Divider+Direction EN954-1, cat 3 / ATEX therm. Sin/Cos/ Marker

I/O expander cards (OPT-B)


Selectable DI/DO 2)

2 2

Sin/Cos + EnDat Encoder out = Resolver simulation EnDat/SSI

Fieldbus cards (OPT-C) RS-485 (Multiprotocol) Probus DP LonWorks Probus DP (D9-type connector) CANopen (slave) DeviceNet RS-485 (Multiprotocol, D9-type connector) CAN / Euromap SELMA 2 protocol Modbus/TCP (Ethernet) BACNet, RS-485 System Bus adapter (2 x ber optic pairs) System Bus adapter (1 x ber optic pair) & CAN-bus adapter (galvanically decoupled) RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypad CAN-bus adapter (galvanically decoupled) Line voltage measurement 2) analogue signals galvanically isolated separately
Modbus, N2

Modbus, N2

Communication cards (OPT-D)

NOTES: Allowed slots for the board are marked in blue. 1) analogue signals galvanically isolated as a group

16

vacon nxp standard i/o


OPT-A1
Terminal 1 1...10 k 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
mA

OPT-A2
Default settings Reference voltage Frequency reference 010 V AI common (GND) Frequency reference 420 mA AI common (differential) Control supply (bidirectional) I/O Ground Start forward Start reverse External fault input Common for DIN1 - DIN3 (GND) Control supply (bidirectional) I/O Ground Multi-step speed select 1 Multi-step speed select 2 Fault reset Common for DIN4 - DIN6 (GND) Output frequency (020 mA) AO common (GND) READY, I < 50 mA, U < 48 VDC Many possibilities Many possibilities Many possibilities Floating Many possibilities 420 mA, 010 V PTC Many possibilities 230 VAC N +24 V GND Many possibilities Many possibilities Many possibilities Floating -10+10 V, 0/420 mA Differential 020mA, 0/-10 V10 V GND 230 VAC N Programmable +24 V GND Terminal 21 R01 22 R01 23 R01 24 R02 25 R02 26 R02 FAULT Many possibilities RUN Many possibilities Default settings Programmable

+10V AI1+ AI1AI2+ AI2+24V GND DIN1 DIN2 DIN3 CMA +24V GND DIN4 DIN5 DIN6 CMB AO1+ AO1DO1

OPT-A3 (alternative)
Terminal 21 R01 22 R01 23 R01 25 R02 26 R02 28 TI1+ 29 TI1Thermistor input FAULT Warning No response FAULT Many possibilities RUN Many possibilities Default settings Programmable

19 20

Default settings of OPT-A1, OPT-A2 and OPT-A3 for the Basic and Standard Applications.

OPT-A4 (encoder input example)


Terminal 1 2 3 4 5 6 7 8 9 DIC1A+ DIC1ADIC2B+ DIC2BDIC3Z+ DIC3ZENC1Q DIC4 GND Qualier input Fast DI Ground for control and inputs ENC1Q and DIC4 Control voltage (auxiliary voltage) output to encoder: Output voltage selectable with jumper X4. Pulse input Z; one pulse per revolution Pulse input B; Phase shift of 90 degrees compared to pulse input A Technical information Pulse input A

10

+5V/+15V/+24V

17

first-class usability
Vacon PC tools can be downloaded from the Vacon website at http://www.vacon.com. They include: Vacon NCDrive for setting, copying, storing, printing, monitoring and controlling parameters Vacon NCLoad for updating software and uploading special software to the drive Vacon NC61131-3 Engineering is available for making tailor-made software. A license key and training are required. The text display with functions such as multi-monitoring, parameter copy, parameter backup and start-up wizard makes commissioning as easy as possible.

The Vacon NCDrive communicates with the drive via the following interfaces: RS-232 Ethernet TCP/IP CAN (fast multiple drive monitoring) CAN@Net (remote monitoring)

plc functionality built in


The Vacon NXP features built-in PLC functionality without the need for any additional hardware. Vacon NC61131-3 Engineering can be used to improve performance and bring cost savings by integrating customer-specic functionality into the drive.

18

software modularity
The All-in-One application package has seven built-in software applications (=default settings and functionality of control inputs and outputs) which can be selected with one parameter. Which software application to use is asked by the Start-up Wizard at the rst power-up. With this single setting, the drive can be programmed for example for two external control places or pressure control with an integrated PID controller.

vacon nxp applications


Instead of the default All-in-One application package, the Vacon NXP can also be equipped with advanced application software. This is designed to meet the requirements of demanding automation applications.

System Interface Application


The System Interface Application is designed to provide a logical, exible interface to machine controllers for use in demanding automation applications.

Fast multiple drive monitoring with NCDrive Control system

Master-follower with drive-to-drive communication

Flexible fieldbus process data connections Flexible speed and torque reference chains Adaptive speed controller Inertia compensation and oscillation damping features Fast drive-to-drive communication for master-follower applications Supports permanent magnet motors Integrated mechanical brake and motor fan control Emergency stop with separate ramp time

19

vacon nxp applications


Position Control Application
The Position Control Application offers an integrated singleaxis interpolating positioning controller for the Vacon NXP. User-specied units for positions Alternative zero calibration cycles Home position Absolute and relative positioning Sequencing Hardware or software based end limits

Shaft Synchronization Application


The Shaft Synchronization Application controls the position or the angle of the follower axis directly or in an adjustable ratio to the master axis. Master position from secondary encoder input Follower position from incremental encoder or resolver Adjustable gear ratio Trim +/- inputs for ratio change during run

Lift Application
The Lift Application offers ready-made lift functions for easy commissioning and tuning of a lift. Induction and permanent magnet motor support Lift speed parameters in [Hz] and [m/s] Integrated lift brake control logic Lift evacuation feature. In case of power failure, the lift can be run to the next oor. In-built motor contactor control logic
Lift drive

Lift car

Permanent magnet motor

High Speed Application


The High Speed Application allows the Vacon NXP to be used with high-speed motors, e.g. in turbo compressors and highspeed spindles. Induction and permanent magnet motor control Ready tested solutions up to 7200 Hz Proven technology for low motor noise and less losses Easy commissioning with standard hardware and software

High-speed drive

Compressor

20

vacon nxp applications


Marine Application
The Marine Application adds support for marine specic functionality that simplies the use of the drive in marine systems. Fast drive-to-drive communication for speed / load share Black out prevention using fast power limit control Full speed and constant power mode control Temperature measurement using PT100 sensors Built-in brake control logic for winches Load drooping

functional safety integrated


The Vacon NXP can help to increase the safety of a system and reduce complexity by offering integrated safety-related functions in the drive, reducing the need for external components and wiring.

Safe disable
The function is intended for use where there is a need to ensure that the motor will not be driven by the drive, ie. for safe standstill, for example when there is a need to perform mechanical maintenance on a machine. In such installations the function may be used to replace mechanical power switches. The function is certied in accordance with EN954-1, Cat 3.

ATEX-certied motor thermal supervision


The ATEX-certied thermistor input of the Vacon NXP is certied for use in supervising the temperature of Ex motors located in potentially explosive areas. The integrated function offers cost savings compared to conventional solutions with external thermistor relays and contactors. The thermal supervision input is certied to be compliant with the ATEX 94/9/EC directive.

21

emc and installation environment

1ST ENVIRONMENT
3 2

4 5

2ND ENVIRONMENT

The product family standard EN61800-3 sets limits for both emissions and immunity to radio frequency disturbances. The environment has been divided into the rst and second environments, in practice, public and industrial networks, respectively. Radio Frequency Interference (RFI) lters are typically required to meet the EN61800-3 standard. These lters are integrated in the Vacon NXP as standard.

The 208240 V and 380500 V ranges of the Vacon NXP (FR4-FR9) meet the requirements of the rst and second environments (H level: EN61800-3(2004), category C2). No additional RFI lters or cabinets are required. The FR10-FR14 and the 500-690 V ranges of the Vacon NXP meet the requirements of the second environment (L-level: EN61800-3(2004), category C3). The units in the frame sizes FR4, FR5 and FR6 (with a voltage range from 380 to 500 V) are also available with extremely lowemission integrated EMC lters (C level: EN61800-3 (2004), category C1). This is sometimes required in very sensitive locations such as hospitals.

EMC Selection Table, restricted distribution


1
Vacon NXP EMC C H L T R = Required ; O = Optional Hospital O R R R O R O R R (IT Network) R (IT Network)

2
Residential Area

3
Commercial

4
Light Industry Area

5
Heavy Industry Marine

22

technical data
Mains connection Input voltage Uin Input frequency Connection to mains Motor connection Output voltage Continuous output current 208240 V; 380500 V; 500...690 V; 10%+10% NXC regenerative low-harmonic drive 525-690 V; -10%...+10% 4566 Hz Once per minute or less (normal case) 0Uin High overloadability: IH, ambient temperature max. +50C (FR10 + 40C) Low overloadability: IL , ambient temperature max. +40C Overloadability Max. starting current Output frequency Control characteristics Control performance High: 1.5 x IH (1 min/10 min), Low: 1.1 x IL (1 min/10 min) Is for 2 s every 20 s 0320 Hz; up to 7200 Hz with special software Open loop vector control (5-150% of base speed): speed control 0.5%, dynamic 0.3%sec, torque lin. <2%, torque rise time ~5 ms Closed loop vector control (entire speed range): speed control 0.01%, dynamic 0.2%sec, torque lin. <2%, torque rise time ~2 ms NX_2/ NX_5: Up to and including NX_0061: 116 kHz; Factory default 10 kHz From NX_0072: 110 kHz; Factory default 3.6 kHz 16 kHz; Factory default 1.5 kHz

Switching frequency

NX_6: Field weakening point Acceleration time Deceleration time Braking Ambient conditions Ambient operating temperature Storage temperature Relative humidity Air quality: - chemical vapours - mechanical particles Altitude Vibration EN50178/EN60068-2-6 Shock EN50178, EN60068-2-27 EMC Immunity Emissions 8320 Hz

03000 sec 03000 sec DC brake: 30% * TN (without brake resistor), ux braking 10C (no frost)+50C: IH (FR10 + 40C) 10C (no frost)+40C: IL 40C+70C 0 to 95% RH, non-condensing, non-corrosive, no dripping water IEC 721-3-3, unit in operation, class 3C2 IEC 721-3-3, unit in operation, class 3S2 100% load capacity (no derating) up to 1000 m 1% derating for each 100 m above 1000 m; max. 3000 m (690 V max. 2000 m) 5...150 Hz: Displacement amplitude 1 mm (peak) at 515.8 Hz (FR10: 0.25 mm (peak) at 531 Hz) Max acceleration amplitude 1 G at 15.8150 Hz (FR10: 1 G at 31150 Hz) UPS Drop Test (for applicable UPS weights) Storage and shipping: max 15 G, 11 ms (in package) Full all EMC immunity requirements EMC level C: EN61800-3 (2004), category C1 EMC level H: EN61800-3 (2004), category C2 EMC level L : EN61800-3 (2004), category C3 EMC level T: Low earth-current solution suitable for IT networks, EN61800-3 (2004), category C4 (can be modied from L/H-level units) EN 50178 (1997), EN 60204-1 (1996), EN 60950 (2000, 3rd edition) (as relevant), IEC 61800-5, CE, UL, CUL; (see unit nameplate for more detailed approvals)

Safety Control connections (OPT-A1, -A2 or OPT-A1, -A3) Analogue input voltage Analogue input current Digital inputs Auxiliary voltage Output reference voltage Analogue output Digital output Relay outputs Thermistor input (OPT-A3) Protections

0+10 V (10 V+10 V joystick control), Ri = 200 k , resolution 0.1%, accuracy 1% 0(4)20 mA, Ri = 250 differential, resolution 0.1%, accuracy 1% 6, positive or negative logic; 1830 VDC +24 V, 15%, max. 250 mA +10 V, +3%, max. load 10 mA 0(4)20 mA; R L max. 500 , resolution 10 bit, accuracy 2% Open collector output, 50 mA/48 V 2 programmable change-over (NO/NC) relay outputs (OPT-A3: NO/NC+NO) Switching capacity: 24 VDC/8 A, 250 VAC/8 A, 125 VDC/0.4 A. Min. switching load: 5 V/10 mA Galvanically isolated, R trip = 4.7 k Overvoltage, undervoltage, earth fault, mains supervision, motor phase supervision, overcurrent, unit overtemperature, motor overload, motor stall, motor underload, short-circuit of +24 V and +10 V reference voltages

23

Vacon Plc Runsorintie 7, 65380 Vaasa, Finland Tel. +358 (0)201 2121, Fax +358 (0)201 212 205 www.vacon.com, e-mail: [email protected]