Air-Cooled Condensers Dry Coolers: More For Less
Air-Cooled Condensers Dry Coolers: More For Less
1100 kW
USE
The drycoolers in the OPERA range are mainly designed for cooling water or glycol/water mix for: - condensers for water chillers, - generators, - processes or machines (presses, compressors, etc.), - free cooling. The air-cooled condensers in the OPERA range are mainly designed for the condensation of refrigerants for water chillers, as a split system.
DESCRIPTION
- Galvanised steel casing, with RAL 7035 paint - Copper tubes, aluminium fins - Hydraulic connection via swivel brackets (drycoolers) - Anti-shear system for bundle tubes - Individual partitioning of the fan motor assemblies - Electrical connection to the motor terminal box
Air
- Each coil is air tested underwater. - Rotation tests, dielectric tests, measuring current for motors with a wiring option.
OPERA
OPERA
Protection
- Fin protective screen - Precoated aluminium fins - High efficiency coating (Altena) on the finned bundle
EC motors
The new generation of EC motors enables progressive control from 0 to 100% by speed variation and brings significant benefits in terms of energy savings and reduced sound levels.
Effects on the sound level
On/Off control Reduction in noise (dBA)
Energy savings
On/Off control
mo
tor
EC
wi
Power input
ol
Co
flow rate
Co
nt
flow rate
ntr
ro
lw
ith
EC
th
ot
or
E: 1240 (1 fan line), 2360 (2 lines) F: 1280 (1 fan line), 2400 (2 lines)
S MODULES 9010-1 A B C D 830 950 9020-1 1780 1900 9030-1 2730 2850 9040-1 1840 3680 3800 9050-1 1840 2790 4630 4750 9040-2 1780 1900 9060-2 2730 2850 9080-2 1840 3680 3800 9100-2 1840 2790 4630 4750 9120-2 2790 5580 5700 9140-2 1840 4690 6530 6650
M MODULES 9010-1 A B C D 1480 1600 9020-1 3080 3200 9030-1 4680 4800 9040-1 3140 6280 6400 9050-1 3140 4740 7880 8000 9040-2 3080 3200 9060-2 4680 4800 9080-2 3140 6280 6400 9100-2 3140 4740 7880 8000 9120-2 4740 9480 9600 9140-2 3140 7940 11080 11200
L MODULES 9010-1 A B C D 1780 1900 9020-1 3680 3800 9030-1 5580 5700 9040-1 3740 7480 7600 9050-1 3740 5640 9380 9500 9040-2 3680 3800 9060-2 5580 5700 9080-2 3740 7480 7600 9100-2 3740 5640 9380 9500 9120-2 5640 11280 11400 9140-2 -
OPERA
OPERA
700/900 560/690 D 82 / 49 85 / 52 87 / 54 88 / 55 89 / 56 88 / 55 90 / 57 91 / 58 92 / 59 93 / 60 93 / 60 Y 66 / 33 69 / 36 71 / 38 72 / 39 73 / 40 72 / 39 74 / 41 75 / 42 76 / 43 77 / 44 77 / 44 D 71 / 38 74 / 41 76 / 43 77 / 44 78 / 45 77 / 44 79 / 46 80 / 47 81 / 48 82 / 49 82 / 49 Y 55 / 22 58 / 25 60 / 27 61 / 28 62 / 29 61 / 28 63 / 30 64 / 31 65 / 32 66 / 33 66 / 33 340/430 D 62 / 29 65 / 32 67 / 34 68 / 35 69 / 36 68 / 35 70 / 37 71 / 38 72 / 39 73 / 40 73 / 40
LEVELS
SOUND POWER LEVELS* / SOUND PRESSURE LEVELS** dB(A) 690/900 D 83 / 50 86 / 53 88 / 55 89 / 56 90 / 57 89 / 56 91 / 58 92 / 59 93 / 60 94 / 61 94 / 61 Y 73 / 40 76 / 43 78 / 45 79 / 46 80 / 47 79 / 46 81 / 48 82 / 49 83 / 50 84 / 51 84 / 51 680/890 D 81 / 48 84 / 51 86 / 53 87 / 54 88 / 55 87 / 54 89 / 56 90 / 57 91 / 58 92 / 59 92 / 59 Rotation speeds (rpm) MODELS 8010-1 8020-1 8030-1 8040-1 8050-1 8040-2 8060-2 8080-2 8100-2 8120-2 8140-2 Y 75 / 42 78 / 45 80 / 47 81 / 48 82 / 49 81 / 48 83 / 50 84 / 51 85 / 52 86 / 53 86 / 53
(*) Only the sound power level is characteristic of the unit. These values are obtained in compliance with the ISO 3744 standard. (**) Values measured at 10 m for horizontal units in free field, directivity 2, in line with the coil. Tolerance 3dB. The difference between the sound power level and pressure level varies according to the site. To determine the units sound pressure level, recalculate it using the sound power level of the unit and the conditions of the site (you may need to consult an acoustical engineer). As the sound emitted by the unit is not uniform in all directions, for a point 10 m away in line with the fans, the recalculated pressure value must be increased by approximately 4 dB.
INSTALLATION
RECOMMENDATIONS
l For air-cooled condensers, the calculation of the evacuation capacity of the air-cooled condenser must be carried out in accordance with professional best practice and particularly in accordance with: - the type of compressor in the installation (hermetic, semihermetic or open), - the horizontal and vertical lengths of the connection pipes and their diameter. l Commissioning and maintenance: refer to the installation, operating and maintenance manual. l These units comply with the European directives. The installer is responsible for ensuring the compliance of the installation. The installer must ensure safety and protective devices (emergency stop, shut-off valves, lightning protection, etc.) are put in place and are accessible.
l These units are designed to operate outside. When starting up, frost and snow could adversely affect the operation of horizontal units. As a general measure, all steps should be taken to avoid the risk of air recycling. This is especially so when the installation comprises several units. It is not recommended to install units near the hot air extraction duct outlet or close to deciduous plants (this could cause clogging). l A horizontal unit must have a surrounding free area of 1.5 m. Where the use of anti-vibration mounts is required, use a rigid frame which locks the feet together. l A vertical unit should preferably be placed parallel to the direction of the wind. It is not recommended for use with low fan rotation speeds. In addition, we recommend that these units be stabilised using braces connecting their two upper ends to fixed supports (wall or framework). l If speed regulators other than those recommended by CIAT are used, their compatibility with the electric motors must be verified.
This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification.