Precia Molen SCL 55t 06-05-02-1ft
Precia Molen SCL 55t 06-05-02-1ft
06-05-02-1 FT
Description
The measurement principle used in the SCL load cell is based
on the deformation of beams to which a compression force is
applied. It uses strain gauges arranged to form a Wheatstone
bridge for conversion of the force to an electrical signal. The
SCL load cell is specially designed to be insensitive to
excentrical loads while remaining compact.
Wiring
V PS. +
Red
V PS.
Bleue
White
Yellow
Shielding
Black
SCL
Applications
# Weighbridges.
# Weighing of tanks, silos, etc...
Available models
General
Options
# Ex version for use in explosive and according to new
directive 94/09/ CE.
Conformity
# Test certificate issued by a notified body in accordance with
OIML recommendation R60.
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Technical data
Dimensions :
Metrological characteristics
Accuracy class*
C3.5
C3.5MB
C1
C5MB C7MB
Maximum range
(Emax)
35/55 t
35/55 t
35/55 t 35/55 t
35/55 t
Verification interval
(v min)
kg
Emax/
11666
Emax/
23333
Emax/
5000
Emax/
23333
Emax/
23333
Electrical characteristics
#
#
#
#
#
#
#
LOAD CELL
5 20V
1 200 60
1 000 10
> 5000 M
2 mV/V 1%
0,05 % S
1%S
Combined error*
%S
0,0180
0,0130
0,0180
0,0130
0,0130
Fidelity error
%S
0,0100
0,0100
0,0100
0,0100
0,0100
Temperature effect on
sensitivity
%S/C 0,0007
0,0007
0,0007
0,0007
0,0007
Effect of temperature on
the signal at minimum
dead load.
%S/C 0,0012
0,0006
0,0012
0,0006
0,0006
.......... 5.
Radius E
SCL-35t
125
16
40
175
SCL-55t
153
23
10
48
225
Environmental characteristics
# Temperature range
Compensated .................................. - 10 C / + 40 C
Operating ......................................... - 40 C / + 80 C
Storage ............................................ - 40 C / + 90 C
# Temperature range version
Compensated .................................. - 10 C / + 40 C
Operating ......................................... - 20 C / + 60 C
Storage ............................................ - 40 C / + 90 C
# Sealing and protection according to DIN 40-050......IP 68
%S
0,0140
0,0070
0,0140
0,0070
0,0070
%S
0,0140
0,0140
0,0140
0,0140
0,0140
* The effect of temperature on the sensitivity and the "combined error" are balanced
so that the sum is less than 70% of the error limit for non-automatic weighing
instruments in accordance with the OIML R76 international recommendation .
The combined error is defined as being the algebraic sum "non-linearity" and
"hysteresis".
Mechanical characteristics
# Load limit ............................................. 150% Emax
# Breaking load....................................... 300% Emax
# Maximum lateral load .......................... 10% Emax
* The "output ratio" is defined as being the quotient of the "output signal" by the "output impedance".
//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////