Agenda
Introduction to Virtual Provisioning
Virtual Provisioning features
FBA
CKD

Virtual Provisioning Benefits


Fully Automated Storage Tiering for Virtual Pools (FAST
VP) Overview

Virtual Provisioning = Thin Provisioning


From wiki:
Thin provisioning is the act of using virtualization technology
to give the appearance of having more physical resources
than are actually available.
Thin provisioning[1] is a mechanism that applies to largescale centralized computer disk storage systems, SANs, and
storage virtualization systems. Thin provisioning allows space
to be easily allocated to servers, on a just-enough and justin-time basis.

Virtual Provisioning is the EMC term for thin provisioning


3

Data Layout disk device

Capacity for a disk device is allocated from a group of


physical disks
Example: RAID 5 with striped data + parity

Workload is spread across multiple physical disk


Logical
Units (LUN)

Physical
Disk Drives

Data Layout Pool-based Allocation


Virtual Provisioning
Storage capacity is structured in pools
Thin devices are disk devices that are provisioned to
hosts
Thin Device Bound to Pool

Thin Device
(TDEV)

Thin Pool

Storage Requirement: Performance


Storage Layout

Go Wide Before Deep!


Goal is to spread workload across all available system
resources
Optimize resource utilization
Maximize performance

Three approaches:
RAID data protection
Meta Devices (Symmetrix)
Virtual Provisioning
6

VP Components
 Thin Data Device (TDAT)
An internal, non-addressable
device
Provides the physical storage for
a thin device
Multiple RAID protection types
RAID 1, RAID 5, RAID 6

 Thin Pool
a shared, physical storage
resource of a single RAID
protection and drive technology
the first TDAT added determines
the protection type

Thin Pool

FC_Raid1
Add (4) x 25GB Raid 1
TDATs

VP Components
 Thin Device (TDEV)

Host-addressable, cache only device


bound to a thin pool and provisioned to hosts
Seen by the operating system as a normal device
Used in the same way as other host-addressable devices
Can be replicated both locally and remotely

Physical storage need not be completely allocated at device


creation
Physical storage is allocated from a thin pool of DATA
devices

 Thin Device Extent


unit of allocation from a thin pool when a host writes to a new
area of a thin device
12 Symmetrix tracks, 768 KB (aka track group)
8

Virtual Provisioning for


FBA (SCSI) devices
with
Linux on System z

VP Concepts for FBA as a SCSI LUN


Virtual Provisioning
Application perceived
thin devices
Reported
capacity
Allocated Allocated

Common
storage
Data
devices pool

10

Thin Provisioning - SCSI


Space efficient technology
Data storage never 100% full
Present thin device to Linux
Only consumes storage as the
host writes to the thin device
Physical storage allocated
from a shared pool

Over Subscription
Thin device capacity > pool

Binding a Thin Device


 A thin device must be bound to a pool in order to be
allocated any storage
 One extent is allocated from the pool when its bound
 Any write to a new area of a thin device will trigger an extent
allocation from the pool the device is bound to
New allocations are performed using a round robin algorithm
to spread extents across all of the enabled data devices in the
thin pool

11

Virtual Provisioning Bind


bind allocates initial extent in thin pool
Thin Pool

Storage Group

FC_Raid1

200GB TDEV

Add (4) x 25GB


Raid 1 TDATs

Bind
TDEV

100GB of Storage Capacity in


Pool

12

Thin Pool is Oversubscribed


2:1

Host sees 200GB Device (Ready)

Virtual Provisioning Writes


Write to new area of tdev will allocate extents in thin pool
Thin Pool

Storage Group

FC_Raid1

200GB TDEV

Add (4) x 25GB


Raid 1 TDATs

1000101

1000101

100GB of Storage Capacity in


Pool

13

Thin Pool is Oversubscribed


2:1

Host Reads from Thin Devices


 Thin devices are cache only devices that contain pointers to
the allocated extents on the data devices
 When a read is performed to a thin device, the data is
retrieved from the appropriate data device
 Reading from a previously unallocated logical block address
will:
return a block containing all zeros
not trigger an allocation of a new extent

14

VP Threshold Settings

15

Over Subscription with SCSI devices


 A thin pool can be over subscribed
Provision more space than exists in the pool

 A thin devices entire configured capacity counts against the


bound pools maximum subscription percentage
Even if the device remains thin (or all of its allocated extents are
promoted/demoted to other pools by FAST VP)

16

Extended Pool Functions and Attributes


 Pool Rebalancing
Rebalancing Variance % - controls whether a data device
(TDAT) will be chosen for a possible rebalance
Maximum Rebalance Scan Device Range the maximum
number of data devices (TDATs) to concurrently balance at
any one time

 Attributes (for FBA as a SCSI device)


Maximum Subscription % - controls whether a pool can be
over subscribed (allocated)
Pool Reserve Capacity (PRC) pools enabled capacity to be
reserved for allocating new extents for the bound devices in
the pool
17

Space Reclamation Use Case


Some migration methods between regular and thin devices
will leave the target thin devices fully allocated
Extents that are allocated on the thin devices may be
eligible to be returned to the thin pool
Some extents may never have been written to by a host
Some extents may contain all zero data

Available capacity in the thin pool can be maximized by


returning unneeded extents back to the pool
Space Reclamation is an extension of the existing Virtual
Provisioning space de-allocation mechanism

18

Space Reclamation Feature


Reclamation operations are run against individual thin
devices
Enginuity* will examine all of the allocated groups on
specified thin device
All tracks will be examined to see if they contain all-zero data

If all tracks in an extent contain all-zero data, the


extent will be de-allocated
Tracks that are marked Never Written By Host (NWBH) do not
need to be examined by Enginuity

Space Reclamation is a slow running process


Enginuity does not reclaim space at the expense of host
performance

*Enginuity is the EMC Symmetrix Storage Operating environment


19

Thin Provisioning cleanup


 Terms are used loosely which can be confusing
 SCSI standard (t10.org) - T10 Technical Committee on SCSI
Storage Interfaces
 Host Based SCSI commands for thin devices
SCSI unmap
SCSI write same with unmap

 Support for these SCSI commands are


kernel dependent Linux vendor and release
Storage array dependent

 Any new technology should be tested and fully understood before being put
into production!
Check the vendors documentation and support matrix for requirements and/or restrictions
20

Thin Provisioning cleanup Terminology


 Unmap
SCSI command
Sent to thin device to unmap (or deallocate) one or more
logical blocks

 Write Same (with unmap flag)


SCSI command to write at least one block and unmap other
logical blocks

 fstrim executable, batch command used on filesystems


 Discard
option on mount and mkfs command for ext4 and xfs
filesystems
controls if filesystem supports the SCSI unmap command so
thin devices can free specific blocks
21

Filesystem mount discard option


 Linux Releases supporting the discard option on the
filesystem mount command
SLES 11 SP2*
RHEL 6.2 with a hot fix and ext4
RHEL 6.3 and ext4

 Storage Array
EMC VMAX @ Enginuity level 5876*
Other?
*Check the vendors support matrix for the specific details

22

Verification of discard support


 Thin device must be mapped and masked to Linux
 Examine file(s) to verify discard support for the device

/sys/bock/<device>/queue / discard_max_bytes
# cat discard_max_bytes
25165824
from kernel.org:
The discard_max_bytes parameter is set by the device driver to the maximum
number of bytes that can be discarded in a single operation. Discard requests
issued to the device must not exceed this limit. A discard_max_bytes value of 0
means that the device does not support discard functionality.

23

Create ext4 filesystem with discard


ext4 filesystem created with discard first discards
blocks on thin device, then creates filesystem
# mke2fs -F -t ext4 -E discard -vvv /dev/sdb
mke2fs 1.41.12 (17-May-2010)
fs_types for mke2fs.conf resolution: 'ext4', 'default'
Discarding device blocks: done
Discard succeeded and will return 0s
table wipe
..

24

- skipping inode

mount ext4 with discard


 Filesystem mounted with the discard option
Frees up space on thin device at time of file deletion
And when the array receives the actual write request
NOTE: there is overhead associated with active discard so this should be
tested in your own environment
mount -o discard -t ext4 /dev/sdb /thin_mount

# mount
/dev/sdb on /thin_mount type ext4 (rw,discard)

25

fstrim
mount ext4 filesystem without discard mount option
Filesystem mounted without the discard option
Does not frees up space on thin device at time of file deletion

You may free up space on a filesystem, where files were previously


deleted, on a thin device with fstrim
fstrim is executed against a filesystem and its underlying thin device
Linux support - release and vendor dependent. Check vendors
support matrix for proper support requirements

26

Virtual Provisioning for


CKD devices
with
Linux on System z

Standard Provisioning Concept (CKD)


101D -3390-9

101E -3390-9

Host
addressable
devices

Front End
(FICON)

Track
mapping
tables

Cache
Back End

Single
RAID rank

Disks

28

Virtual (thin) Provisioning Concept


Thin
devices

101D -3390-9

101E -3390-9

Front End
(FICON)

Track group
mapping
tables

Cache
Back End

Virtual Pool

Disks

Data
devices

29

VP Components for CKD


 CKD VP components are same for CKD as they are for
FBA:
Thin Pool a shared, physical storage resource of a single
RAID protection and drive technology
Data Device (TDAT) RAID protected devices that provide
the actual storage for a thin pool
Thin Device (TDEV) cache only devices that are bound to a
thin pool and provisioned to hosts
Thin Device Extent allocation unit from a thin pool when a
host writes to a new area of a thin device
12 Symmetrix tracks, 768 KB (aka track group)

30

VP for CKD with Linux on System z


Present thin CKD device to z/VM and/or Linux on z
Thin CKD device must be fully provisioned for z/VM and
Linux
Initial format of thin CKD device fully allocates device
cpfmtxa
dasdfmt

Benefits
Wide striping
EMC FAST Fully Automated Storage Tiering

31

Common Functions of VP for CKD and FBA


Underlying VP technology is the same for FBA and CKD
therefore certain management activities are also the same
Rebalancing
Drain
Fully Automated Storage Tiering (FAST)

32

Rebalancing
Should be started after adding new TDATs to an existing
pool
Runs at a very low priority
Can be influenced by two extended pool attributes:
Rebalancing Variance %
controls whether a data device (TDAT) will be chosen for a
possible rebalance

Maximum Rebalance Scan Device Range


the maximum number of data devices (TDATs) to concurrently balance
at any one time

33

VP Benefits
Improved capacity utilization (with VP LUNs and Linux)
Reduces the amount of allocated but unused physical storage
Avoids over-allocation of physical storage to applications

Efficient utilization of available resources

Wide striping distributes I/O across spindles


Reduces disk contention and enhances performance
Maximizes return on investment

Ease and speed of provisioning

Simplifies data layout


Lowers operational and administrative costs

Basis for Automated Tiering (FAST VP)


Active performance management at a sub-volume, sub dataset
level
34

Basis for FAST


With information growth trends, all
Fibre Channel (FC) configurations will:

EFD

FC

SATA

Cost too much


Consume too much energy
Take up too much space

Skew: At any given time, only a small


address range is active the smaller
the range, the better
Persistence: If an address range is
active (or inactive), it remains so for a
while the longer the duration, the
better

Workload

FAST helps by leveraging disk drive


technologies
What makes FAST work in real-world
environments?

80% of IOs on 20% of capacity

35

Fully Automated Storage Tiering VP


FAST VP is a policy-based system that promotes and
demotes data at the sub-volume, and more importantly,
sub-dataset/sub-lun which makes it responsive to the
workload and efficient in its use of control unit resources
Performance behavior analysis is ongoing
Active performance management
FAST VP delivers all these benefits without using any
host resources

36

Virtual Provisioning with Tiers


VP_ProdApp1

TDAT
R53

TDAT
R53

TDAT
R1

TDAT
R1

TDAT
R1

TDAT
R614

TDAT
R614

TDAT
R614

TDAT
R614

TDAT
R614

TDAT
R53

TDAT
R53

TDAT
R1

TDAT
R1

TDAT
R1

TDAT
R614

TDAT
R614

TDAT
R614

TDAT
R614

TDAT
R614

R53_EFD_Pool
37

VP_DevApp1

R1_FC_Pool

R6_SATA_Pool

Storage Elements
Symmetrix Tier a shared storage resource with
common technologies (Virtual Pools)
FAST Policy manage Symmetrix Tiers to achieve
service levels for one or more Storage Groups
FAST Storage Group logical grouping of thin devices
for common management
FAST Storage
Groups

FAST Policies
Automatic

<100%
100%

Custom

38

R53_EFD_200GB
200 GB EFD
RAID 5 (3+1)

R1_FC_450GB

VP_Prod_DB2

VP_QA_DB2

Symmetrix Tiers

x%
y%
z%

450 GB 15K FC
RAID 1
R66_SATA_1TB
1 TB SATA
RAID 6 (6+2)

FAST VP Implementation
Performance data collected by
the system
Intelligent Tiering algorithm
generates movement requests
based on performance data
Allocation Compliance
algorithm generates movement
requests based on capacity
utilization
Algorithms continuously assess
I/O statistics and capacity use,
and make decisions for
promotion and demotion
39

Performance Data
Collection

Analyze
Performance Data

Intelligent Tiering
Algorithm

Execute Data
Movement

Allocation
Compliance
Algorithm

Summary
Virtual Provisioning = Thin Provisioning
Available for FBA/SCSI and CKD devices
FBA as SCSI devices
Space is allocated as needed
Over subscription
Cleanup of unused space via space reclamation or T10 SCSI
command standards
Linux and Storage array dependent

CKD
Fully allocated

Wide Striping
FAST VP Fully Automated Storage Tiering VP
Active performance management

40

THANK YOU
Gail Riley
EMC Corporation
[email protected]

You might also like