Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Emission Line

1.110.01

Isokinetic Heated Probe


Heated Probe
Main Characteristics:

.
.
.
.

The materials used for sample


collection must be compatible with
gas composition to ensure the
integrity of compounds that should be
determined.
To meet these requests, TCR
TECORA studied and developed a
standard isokinetic probe to be
assembled in accordance with
applications.

Heated probe body


Length

P/N *

(useful "L" mm)

1000
AC99-090-0001SP
1500
AC99-090-0002SP
2000
AC99-090-0003SP
2500
AC99-090-0004SP
3000
AC99-090-0005SP
Other lengths on request

The main body of the probe has a


circular section with a diameter of 42
mm, available in some standard
lengths.
Inside of it a tube slides which is
electrically heated by a wire that is not
in contact with stack gases.

An expansion cylinder absorbs


dilation differences allowing to realise
probes up to 5 m length with no
deformation.

. Max. operation temperature: 400C


. Max. heating temperature = 200C
+ ambient temperature

The suction tube and the final connector


are not included in probe code

"L"

Heated Box for filterholder


Wishing to use the technique of out
stack filterholder it is necessary to
heat also the filterholder to prevent
water vapour and some volatile
organic compounds condensation.
For this purpose it is available an inox
heated box already prepared for a
quick connection to the heated probe.

The maximum temperature of heating


can be 160C higher than the ambient
temperature.
The sufficient isolation allows to
maintain the outside temperature at
not dangerous values for the user.

In heated box can be placed several


filterholders for doing measure in a
wide range of particulate
concentration.

P/N Heated box AC99-092-0000SP

A Tecora unified connector is used for


temperature control.
The heated box is supplied with fixing
device of glass curve-nozzle.

Product Data Emission Line 1.110.01

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

change and available in inox,


glass, titan, and quartz.
Total isolation of heating element
and thermocouple from stack gases.
Special property to connect
isokinetic kit, filterholder and
nozzles, in or out of the stack.
Possibility of mounting orifice
The moisture content of the sampled
meter for wet gas flow rate
gases obliges to heat not only the
sampling.
probe but often also the collection
devices.
Clamps for Pitot tube with
The material of the internal body of
thermocouple.
probe ensures not only the necessary
Auxiliary outputs for extended
rigidity but also a certain resistance to
measurements.
temperature and corrosion caused by
aggressive gases.

Ed. 0 02/04 - Technical specifications may change without previous warning

. Probe body in AISI 316


. Internal suction tube easy to

Emission Line

1.110.02

Isokinetic Heated Probe


Suction Tubes and Pitot Tubes

P/N

(useful "L" mm)

material INOX AISI 316

1000
AC99-090-9901SP
1500
AC99-090-9902SP
2000
AC99-090-9903SP
2500
AC99-090-9904SP
3000
AC99-090-9905SP
Other lengths on request

material TITANIUM

AC99-090-9911SP
AC99-090-9912SP
AC99-090-9913SP
AC99-090-9914SP
AC99-090-9915SP

Glass and quartz suction tubes

Available in glass and quartz, the


suction tubes ends with a leak proof
ball joint of 19 mm that can
accomodate either the isokinetic kit or
the glass curve-nozzles.

Length

P/N

(useful "L" mm)

material GLASS

1000
AC99-090-9941SN
1500
AC99-090-9942SN
2000
AC99-090-9943SN
2500
AC99-090-9944SN
3000
AC99-090-9945SN
Other lengths on request

material QUARTZ

AC99-090-9951SN
AC99-090-9952SN
AC99-090-9953SN
AC99-090-9954SN
AC99-090-9955SN

Pitot tubes and thermocouple

The "S" Pitot tube with thermocouple


for measuring the gas temperature
can be easily clamped to the heated
probe.
The final part of "S" Pitot tube is
detachable to allow a replacement in
case of damage or for determination
of the calibration factor.

Probe length ("L" mm)


1000
1500
2000
2500

The final part of "S" Pitot tube is


realised in two lengths:

3000

w/ Pitot "S" L
w/ Pitot "S" S
w/ Pitot "S" L
w/ Pitot "S" S
w/ Pitot "S" L
w/ Pitot "S" S
w/ Pitot "S" L
w/ Pitot "S" S
w/ Pitot "S" L
w/ Pitot "S" S

P/N
AC99-090-0041SP
AC99-090-0051SP
AC99-090-0042SP
AC99-090-0052SP
AC99-090-0043SP
AC99-090-0053SP
AC99-090-0044SP
AC99-090-0054SP
AC99-090-0045SP
AC99-090-0055SP

- Long one - L for sampling with in-stack


filter assembly
- Short one - S for sampling with out-stack
filter assembly
"S" Type Pitot Tube - L P/N AC99-098-9900SP

"S" Type Pitot Tube - S P/N AC99-098-9901SP

Ed. 0 02/04 - Technical specifications may change without previous warning

Available in AISI 316 and Titanium,


ends with a cone shaped metal to
metal connection that can
accomodate the isokinetic kit, either in
AISI 316 or Titan, as well as directly
the curve-nozzles.

Length

Product Data Emission Line 1.110.02

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

Metal suction tube

Emission Line 1.110.03


Isokinetic Heated Probe
"Out Stack" Filter Assembly
Filterholder for membrane

Diam. 25 mm

Diam. 47 mm

Diam. 90 mm

This filterholder can accept thimble


diam. 25 mm, length 100 mm,
available on the market in glass fibre
as well as in high purity quartz fibre.

Available in glass or quartz, supplied


with membrane support in PTFE.
On request the membrane support
is available in Titan.
It is supplied complete with light alloy
fastening ring.

Available in glass or quartz, supplied


with membrane support in Titan.

Supplied complete with INOX 316 inox


fastening ring.

P/N Glass
P/N Quartz

AC99-092-0011SP
AC99-092-0021SP

It is supplied complete with light alloy


fastening ring.

P/N Glass
AC99-092-0030SP
P/N Quartz
AC99-092-0040SP
Support in Titanium
P/N
AC99-092-0039SP

P/N Glass
P/N Quartz

AC99-092-0018SP
AC99-092-0060SP

Kit to use the 47mm inox steel or titanium filterholder in the heated box
Using this kit, composed by two adapters, its
possible to use the filterholder for 47mm flat
membranes (see Emission Line 1.104.01) placing it
in the heated box of the probe for micropollutants.
The front connector fit to the outlet of the probe
while the rear connector is equipped with a spherical
joint fully compatible with all our glassware kits.
The kit is available in stainless steel (INOX 316) and
in Titanium.

P/N Inox
P/N Titanium

AC99-099-0013KP
AC99-099-0011KP

Nozzles made of INOX 316, Titanium, Glass and Quartz


Curve and nozzle made of INOX 316 and titanium
The new curve for interchangeable
nozzles is in accordance with ISO
9096 and EN 13284

Nozzles made of glass and quartz

It is available in INOX 316 and


Titanium.
It can be used with nozzles that
appear in the product data numer
1.104.03 which are useful either for
out stack or in stack applications.
These nozzles can be bought either
as a kit of 8 with different diameters,
or separately.

Curve for out stack


filterholder
INOX 316 P/N AC99-106-0011SP
Titanio P/N AC99-105-0011SP

Nozzle curve made of glass and quartz


Diameter (mm)

8 interchangeable nozzles kit


INOX 316 P/N AC99-106-0016KP
Titanio P/N AC99-105-0016KP

Gooseneck curve series are available


with glass or quartz nozzle equipped
with a spherical connection.

12
10
08
07
06
05
04

Glass
AC99-090-9966SN
AC99-090-9965SN
AC99-090-9964SN
AC99-090-9963SN
AC99-090-9962SN
AC99-090-9961SN
AC99-090-9960SN

Quartz
AC99-090-9976SN
AC99-090-9975SN
AC99-090-9974SN
AC99-090-9973SN
AC99-090-9972SN
AC99-090-9971SN
AC99-090-9970SN

Product Data Emission Line 1.110.03 Ed. 2 09/06 - Technical specifications may change without previous warning

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. +39 02 4505501 Fax. +39 02 48601811 - www.tecora.it e-mail: [email protected]

Filterholder for thimble

Emission Line

1.110.04

Isokinetic Heated Probe


"In Stack" Filter Assembly
Inox filterholder

TCR Tecora has realized a practical


and secure system which allows the
isokinetic kit in glass to be mounted in
stack.

The small overall dimensions of the


probe along with the filterholder and
the Pitot tube allow it to pass through
a standard 4" port.

Filterholder for thimble


Diam. 25 mm

Filterholder for membrane


Diam. 47 mm

Inox device to accomodate


glass filterholder

Offered both in glass and quartz, it


can accomodate thimbles diameter
25x100 mm, that are available on the
market in glass fiber as well as in
ultrapure quartz fiber.
The filterholder is assembled by two
inox rings.
/ 19 mm
The sealing is ensured by O
spherical joints.

Offered both in glass and quartz, it


/ 47 mm flat membranes
can receive O
that are available in glass fiber as well
as in ultrapure quartz fiber.
The support of the membrane is in
sintered glass.
The filterholder is assembled using
two inox rings.

This device in AISI 316, is connected


to the heated probe incorporating
a glass suction tube.
The glass filterholder is located and
protected inside this device; a
bayonet clamp on three points
ensures the easy and secure
assembling.

Ed. 0 02/04

In particular application such as heavy


metals or micropollutants
determination, it is advisable to use a
complete sampling line in glass.
For constructive reasons the use of
isokinetic kit in glass was restricted to
the method which previewed the
external filterholder.

- Technical specifications may change without previous warning

Glass and quartz filterholders

P/N Glass
P/N Qaartz

AC99-091-0010SP
AC99-091-0020SP

P/N Glass
P/N Quartz

AC99-091-0012SP
AC99-091-0022SP

P/N AC99-091-0000SP

Nozzles for glass and quartz filterholder "In Stack"


These nozzles are provided with
spherical coupling to the filterholder.
The character of glass and quartz as
materials doesn't allow to realize the
nozzles, especially their inlet edge, in
accordance with the standard
recommendations.

Nozzle diameters (mm) P/N - Glass


12
10
08
07
06
05
04

AC99-091-9916SN
AC99-091-9915SN
AC99-091-9914SN
AC99-091-9913SN
AC99-091-9912SN
AC99-091-9911SN
AC99-091-9910SN

Quartz
AC99-091-9926SN
AC99-091-9925SN
AC99-091-9924SN
AC99-091-9923SN
AC99-091-9922SN
AC99-091-9921SN
AC99-091-9920SN

Product Data Emission Line 1.110.04

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

The filterholders described in Product Data 1.104.02 "Isokinetic Filter Assembly" can be used.

Emission Line

1.110.05

Isokinetic Heated Probe


Accessories
Depending on the probe length, there
are two different slide and lock
devices that can be used for fixing the
heated probe to the stack.

The slide and lock device


incorporates a special universal
flange plate that allows it to join to any
flange with 160-220 mm distance
between the holes (dimension "A").

Therefore the stack has to be


equipped with a O
/ 4" port fitted with
the flange.

For up to 1,5 m long probes, light


alloy device is used.
8

B = flange distance
S = stack wall
L = probe length
200

P/N

90

10

AC99-090-9800SP

For over 1.5 m long probes, an


alternative slide and lock device is
available that is also realized in light
alloy and already fitted with the
universal flange of greater dimensions
and consistency so that it provides
greater support for the probe to
move.
1

90

120

Assembling dimensions of over 1.5 m length probe with out stack filter

S
190

220

90

Assembling dimensions of over 1.5 m length probe with in stack filter

190

200

P/N

10

AC99-090-9801SP
S

220

B
L

90

Product Data Emission Line 1.110.05

320

Ed. 0 02/04 - Technical specifications may change without previous warning

Assembling dimensions of up to 1.5 m length probe

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

Slide and lock devices for probes

Carrying Case
Carrying case for isokinetic
sampling kit in glass
Metal frame case, fire painted with
foam cut out to accommodate 1
filterholder diam 47mm, 1 thimble
holder, 3 baskets, 5 glass nozzles.
It is supplied with spare gaskets for
both filterholder
Size: 38 x 23 x 8 cm
Cod. AC99-092-9930SP

Emission Line

1.110.06

Isokinetic Heated Probe


Condensing and adsorbing device MCS2 for the determination
of PCDD/PCDF in compliance to EN 1948 Method

The EN 1948-1 Filter condenser


method foresee the isokinetic
sampling with a heated probe,
filterholder and adsorbing trap
XAD2/PUF after the condenser.
This system is dedicated to the
determination of the following
compounds:
Polycyclic Aromatic Hydrocarbons
(PAH)
Polychlorinated dibenzo dioxins
(PCDD)

Allowed materials are Titan, Quartz


and Glass.
The
mod.
MCS2
condenser
(Micro-pollutants
Condensation
System rev.2), equipped with the
cooling unit mod. ISOFROST, meets
the requirements of the standard and
grants a precise and automatic
temperature control of the gas after
the condenser needed for long term
samplings.

Condensing and Adsorbing trap device mod. MCS2


The MCS2 is the evolution of the
former MCS condensation system.
In this new version, particular
attention has been dedicated to the
treatment and transport of the sample.

the direct assembing to the heated


probe, the absence of silicon
connection tubes are the strenght
points of the system and make it easy
to be handled and used on the field.

The adsorbing trap XAD2/PUF and


the condense collection flask can be
quickly changed and sealed with
caps for the transport.

Note:
To use the MCS condensing device
with the heated probe is necessary
the Fixing Kit P/N

Cod. AC99-095-0002SN

AC99-095-9901KP
The compact and rugged realization,

Spare parts and accessories


Description
4

8
7
8

9
10

P/N

1 Condenser

AC99-095-0020SN

2 1 liter condense collection flask with cap

AC99-095-0021SN

3 Trap for adsorbent with caps

AC99-095-0024SN

4 Gas inlet connector

999VE188

5 Dry gas outlet with temperature probe inlet

999VE186

6 Adsorbent trap gas inlet adapter

999VE187

7 Condense flask fixing nipple

999EB080

8 PTFE - MVQ gaskets

999UC044

9 Cap with quick connector

999HA136

10 Hosebarb connector for the cooling liquid

999RB343

Carrying case for MCS2 and accessories

AC99-095-9905SP

Ed.2 01/05 - Technical specifications may change without previous warning

Polychlorinated dibenzo furans


(PCDF)
Polychlorinated biphenils (PCB)

Product Data Emission Line 1.110.06

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

Filter condenser Method - Condensation with adsorbing trap on dry gas

Emission Line

1.110.07

Isokinetic Heated Probe


Condensing and Adsorbing Device EPAMCS2 for the Determination
of PCDD/PCDF in Compliance to EPA 23 and EN 1948 Method

(PCDD)
Polychlorinated Dibenzo Furans
(PCDF)
Polychlorinated Biphenils (PCB)

Cooler liquid exit

The EPA 23 and EN 1948-1 methods


foresee the isokinetic sampling line
with a heated probe, filterholder and
XAD2 adsorbing trap for both gas and
condensate.

Cooler liquid inlet


Cooling bath with
circulating pump
mod, IGLOO P

This system is dedicated to the


determination of the following
compounds:
Polycyclic Aromatic Hydrocarbons
(PAH)
Polychlorinated Dibenzo Dioxins

Condensing Device and Adsorbing Trap


EPAMCS2 P/N AC99-095-0003SN
The adsorbent trap for solid materials
provided with cap allows the quick
substitution and sealing during
transportation avoiding the transfer
and manipulation of the samples on
the field.
The compact and robust execution,
the direct fixing to the heated probe,
the absence of tubes or mobile
connections are the strength points of
this system and make it particularly
easy to handle respect to other
systems.

To use the condensing device


EPAMCS with heated probe a fixing
kit is necessary.
Fixing Kit P/N AC99-095-9901KP

Allowed materials are Titan, Quartz


and Glass.
The sampling line in accordance to
the methods is composed by the
EPAMCS2 condenser, the cooling
bath unit mod. IGLOO P and a set
impingers.
For more information about IGLOO-P
see product data :
Emission Line1.012.01

Set of Glassware EPA 23


P/N AC99-096-0001SN
Consists of:
1. N 5 Washing bottles with threaded
rings
2. N 4 U Tubes
3. Temperature tip on gas outlet
4. Thermometer
2

3
1

Note:
4

Spare Parts and Accessories


4

10

8
7
8

Description

P/N

1 Condensing system

AC99-095-0020SN

2 XAD2 Refrigerated trap

AC99-095-0025SN

4 Inlet gas connector

999VE188

7 Fixing nipple for condensed vapour collection flask

999EB080

8 Gasket PTFE - MVQ

999UC044

10 Inlet hosebarb for cooling liquid

999RB343

Carrying case for MCS2 and accessories

AC99-095-9905SP

Product Data Emission Line 1.110.07 Ed.2 01/05 - Technical specifications may change without previous warning

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

Filter condenser Method - Adsorbing Trap on Gas and Condensate

Emission Line

1.110.08

Isokinetic Heated Probe


Accessories for Sampling Line Method US-EPA
The used configuration needs a
heated sampling probe with out stack
filter in accordance with US EPA 5
Method.
The special modularity realization of

Cooling Bath for n6 Impingers

Glassware

Support for EPA Device

The cooling bath can be quickly


connected to the heated probe
through a support as it is shown in the
design.

P/N AC99-096-0013SP

A support kit is necessary for


mounting the cooling bath or the
MCS condensing system to the
heated probe equipped with a
heated box.

P/N AC99-095-9901KP

To decide about the necessary accessories for the specified determination please refer to the TCR Tecora sampling
line.

EPA 500 cc Free Tube Impinger

EPA 500 cc Plate Impinger

Gas Inlet Adapter

Equipped with threaded ring with


screw joints and gasket in PTFE.

Equipped with threaded ring with


screw joints and gasket in PTFE.

Equipped with spherical joint with


O-ring in Viton.

P/N AC99-096-9900SN

P/N AC99-096-9901SN

"U" Tube for Impinger EPA

Outlet Temperature Joint for


Impinger EPA

It is necessary for connecting two


impingers.

Equipped with outlet with ring with


screw joints and gasket for inserting a
thermometer.

P/N AC99-096-9907SN

P/N AC99-096-9905SN

P/N AC99-096-9908SN

Ed. 0 02/04 - Technical specifications may change without previous warning

Consists of a thermo isolated


stainless inox box.
Inside the box, there are up to 6
impingers of 500 cc. fitted.

our probes allows the separation of


the different elements for the simple
transport managing, and so giving
possibility to reconfigure the probes
for other reference methods.

Product Data Emission Line 1.110.08

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

Some EPA methods for compound


sampling in gaseous phase are
provided for using an impinger train
that is placed on the back of the
probe.

Emission Line

1.110.09

Isokinetic Heated probe


ISOTERM Thermoregulator Units

The connections are unified to allow


the widest versatility of use.

ISOTERM 4

In the 2 and 3 output models it is


possible to insert alarm thresholds
that activate a built-in sound and
visual signal.

P/N AC99-090-0090SP

With these units it is possible to


control:
- heated probes
- external filterholder box at the stack
- heated sampling lines
- wet gas meter

ISOTERM 2
P/N AC99-090-0094SP

Standard power cords:


Length
4m
8m

P/N
AC99-090-0091SP
AC99-090-0092SP

ISOTERM 1
P/N AC99-090-0093SP

Ed. 0 04/07 - Technical specifications may change without previous warning

Through the electronic PID regulators


it is possible to measure and control
the heated temperature in a precise
and effective way.

Product Data Emission Line 1.110.05

TCR TECORA s.r.l. Via Alessandro Volta, 22/24 - 20094 Corsico (Mi) Italy - Tel. 02 4505501 Fax. 02 48601811 - www.tecora.it e-mail: [email protected]

The ISOTERM thermoregulation


devices are available in three different
configurations that provide 1, 2 or 4
outputs.