Klemsan Energy Management Solutions Catalogue
Klemsan Energy Management Solutions Catalogue
Klemsan Energy Management Solutions Catalogue
You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software
With ETOR Gateway and Systemon software, you can read and invoice electric, naturel gas and
water meters as a sub-metering application automatically.
With Rapidus, you can always keep your facilitys reactive energy under control and never pay unexpected penalties.
With Klea and Ecras you can monitor, save and analyze energy consumptions. You can make saving decisions.
Factories
With Rapidus you can monitor your reactive energy remotely and you do not make unnecessary service and
never pay unexpected penalties.
With Klea and Ecras you can monitor, save and analyze energy consumptions. You can save expenses
and decrease your carbon emission.
You can monitor, record and analyze your energy parameters and quality. You can minimize loss and leakage in your system.
With Rapidus you can keep your reactive energy consumption under control and you can monitor all energy parameters
with its advanced power measurement features.
Moduler design
No connector cables
No fixing screws
State of the art technology
Easy
mounting on panels
connection to system
Water
Meter
Gas
Meter
Quantity
Counting
KLEA
MOBDUS
Distribution
Panel
TCP/IP
ETOR
Genset
Utility
KLEA
TCP/IP
LOAD
ETOR
MOBDUS
RS 485
NETWORK
11
12
10
T1-1
T1-3
T1-2
4
5
Demand Management
User can adjust demand period between 1 to 60 minutes.
Klea keeps demand for I, P ,Q, and, S for each phase.
Klea monitors P, Q, S and I values and gets the average values of
4 parameters for each demand period.
Klea logs the maximum value of the average values in a month.
Klea keeps 4 months demand logs for 4 parameters with time stamp.
P, Q, S and I values are measured for each phase and sum.
Data Logging
Klea measures
Klea logs
Klea logs
Klea logs
1 MB Memory
100 A
5A
1 sec.
Klea current inputs can withstand surges upto 100 A for 1 second.
In medium voltage applications, current transformers may generate
peak currents in secondary windings. These peak values may reach
upto 100 A and as a result of this current inputs of the analyzer may
burn out and create an open circuit for secondary connections of
the CT.
This may result with an explosion on CT since secondary side is
open circuited.
Function
Function
Performance Class
According to IEC
61557-12
0,2
QV
SA
0,2
EA
0,2
0 to 49999999999
ERV
0 to 49999999999
Frequency
0,05
45 - 65 Hz
Phase current
0,2
20 % Ib I Imax
INc
Neutral current
0,5
20 % Ib I Imax
Voltage
0,2
Umin U Umax
PFA
Power factor
0,5
THDV
0 % to 20 %
THDI
0 % to 100 %
Measuring Range
Other
Complementary
Characteristics
Other Features
Graphical LCD
Language Support
Harmonics Measurement upto 51
Advanced Alarm Settings
Real Time Clock
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W Aron
4
TT, TN, IT
0.2
0.2
0.5
512
< 3VA
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W Aron
4
TT, TN, IT
0.2
0.2
0.5
512
< 3VA
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W Aron
4
TT, TN, IT
0.2
0.2
0.5
512
< 3VA
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W Aron
4
TT, TN, IT
0.2
0.2
0.5
512
< 3VA
Upto 51st
*
*
*
Upto 51st
*
*
*
Upto 51st
*
*
*
Upto 51st
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
300 V Cat II
1-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
300 V Cat II
1-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
300 V Cat II
1-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
300 V Cat II
1-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
2
10 A
250 VAC
1250 VA
2
100 Hz, 10 ms
Dry Contact
2
5-30 VDC
20 Hz, 50 ms
3750 Vrms
0
2
10 A
250 VAC
1250 VA
7
100 Hz, 10 ms
Dry Contact
7
5-30 VDC
20 Hz, 50 ms
3750 Vrms
0
2
10 A
250 VAC
1250 VA
2
100 Hz, 10 ms
Dry Contact
2
5-30 VDC
20 Hz, 50 ms
3750 Vrms
2
2
10 A
250 VAC
1250 VA
2
100 Hz, 10 ms
Dry Contact
2
5-30 VDC
20 Hz, 50 ms
3750 Vrms
4
*
Isolated
*
Nonisolated
0,404 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
0,428 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
0,428 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
0,428 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
*
*
*
*
*
*
*
*
*
*
*
*
EN 61000-4-2
EN 61000-4-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-8
EN 61000-4-11
EN 61000-4-8
EN 61000-4-11
EN 61000-4-8
EN 61000-4-11
EN 55011/A1:2010
EN 55011/A1:2010
EN 55011/A1:2010
EN 55011/A1:2010
General
Graphical LCD 6 buttons
Password Protection
Supply Voltage AC
Supply Voltage DC
Current Transformer Ratio
Voltage Transformer Ratio
Connection Type
Measurement in Quadrants
Networks
Accuracy Class Voltage
Accuracy Class Current
Accuracy Class Active Energy
Number of Measurement in a period
Power Consumption
Power Quality Measurements
Harmonics / current and voltage
THD-Voltage in %
THD-Current in %
Phasor Diagram
Data Logging
Average, Minimum, Maximum Values
Alarms
Time Stamp
Demand
Voltage Measurement Input
Overvoltage Category
Measured Range L-N
Measured Range L-L
Measured Frequency Range
Power Consumption
Sampling Freq.between 45-65 Hz
Current Measurement Input
Rated Current
Measurement Range
Overvoltage Category
Measurement Surge Voltage
Power Consumption
Peak current for 1 sec
Sampling Freq.between 45-65 Hz
Input Outputs
Relay Outputs
Max. Switching Current
Max. Switching Voltage
Max. Switching Power
Digital Inputs
Minimum Counting Frequency
Input Present or Not
Digital Outputs
Switching Voltage Range
Minimum Switching Frequency
Isolation Level
Analog Outputs
Range of Outputs
0-5 V, 0-10 V, -5-5 V, -10-10V, 0-20 mA, 4-20 mA
Isolation
Mechanical Properties
Weight
Protection Class
Assembly Type
Dimensions
Cable Cross Sections
Supply Voltage, Current, Relay Outputs
Stranded:
Solid:
Digital I/O, RS 485
Stranded:
Solid:
Ambient Conditions
Operating Temperature
Storage Temperature
Relative Humidity (no condensation)
Communication and Others
Modbus RTU
Battery
Real Time Clock
Standarts in Compliance
Safety requirements for electrical equipment
for measurement, control, and laboratory use
Dimensions (mm)
Wiring Diagrams
Moduler design
No connector cables
No fixing screws
State of the art technology
Easy
mounting on panels
connection to system
Instanteneous Measurement
Each phase VL-N and its averages.
Each phase VL-L and its averages.
Each phase I and its sum.
Neutral Current
Each phase active power(P) and its sum.
Each phase reactive power(Q) and its sum.
Each phase apparent power(S) and its sum.
Each phase power factor(PF) and its average.
Frequency
Data Logging
Ecras measures 30 different energy parameters.
Ecras logs min and max values of the measured parameters
Ecras logs demand values for I, Q, P and S.
Alarms
Low limit, High Limit, Hysterysis and Delay Values can be set from the
Alarm Menu for the below parameters:
VL-N, V L-L, I, IN, PF and F
Phase sequence
Absence of Voltage and Current
Can be detected by Ecras and indicates each alarm by blinking
leds on its front panel.
User can activate two output relays by assigning them individually to
any alarm.
1 sec.
Ecras current inputs can withstand surges upto 100 A for 1 second.
In case of a current rise in the secondary winding of the current
transformer, current inputs of the multimeter should withstand to
these peak values. If not, current transformer may explode due to
open circuit in the secondary winding.
This may result with shutdown of the measurement system.
606200 ECRAS
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W
4
TT, TN, IT
0.2
0.2
0.5
512
+ - 1 digit
< 6VA
*
*
85-300 V AC
85-300 V DC
1-5000 A
1-5000 A
3P4W, 3P3W
4
TT, TN, IT
0.2
0.2
0.5
512
+ - 1 digit
< 6VA
*
*
*
*
*
*
*
*
*
*
*
*
*
*
300 V Cat II
10-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
300 V Cat II
10-300 Vrms
2-500 Vrms
45-65 Hz
<0.1 VA
25,6 kHz
6A
0.01-5,5A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-5,5A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
2
10 A
250 VAC
1250 VA
0,291 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
0,292 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
*
*
*
*
*
*
Dimensions (mm)
Wiring Diagrams
Measuring
Current
Measuring
Voltage
Measuring
Current
Measuring
Voltage
Moduler design
No connector cables
No fixing screws
State of the art technology
Easy
mounting on panels
connection to system
Initial Values
Contactors
C1
C2
C3
C4
10 kvar
10 kvar
20 kvar
MOBDUS - RS 485
Contactors
C1
C2
C3
C4
3 kvar
1 kvar
0 kvar
Means
Means
capacitor should
be changed
Capacitor/Reactor---1P/3P
Rapidus can be connected to either single or three phase capacitors or reactors.
Rapidus can be used in Data Centers or Mining Areas where the load is frequently capacitive.
Rapidus can be used with a selection of capacitors and reactors in single or three phase connections.
3 Phase Reactor
1 Phase Reactor
- Fig. A
Mono Phase
Capacitor
3 Phase Capacitor
3 Phase Capacitor
- Fig. B
V1
V1
V2
V2
V3
V3
K3 L2 K2 L1 K1
V1 V2 V3 N
K3
Correct connection
L3 L2 K2 K1 L1
V1 V3 V2 N
Wrong connection
Saving On
Extra multimeter / analyzer cost
Wiring cost
Labor cost
Data Logging
Rapidus measures
68 different energy parameters.
Rapidus logs
80 days hourly
240 days daily
36 months monthly real time measurements of 68 parameters.
Rapidus logs
demand values for P. Q, S, I
Rapidus logs
50 recent alarms with time stamp.
1 MB Memory
100 A
5A
1 sec.
Rapidus current inputs can withstand surges upto 100 A for 1 second.
In case of a current rise in the secondary winding of the current
transformer, current inputs of the PFC should withstand to these peak
values. If not, current transformer may explode due to open circuit in the
secondary winding.
This may result with shutdown of the compensation system and
compensation penalty for the end-user.
Function
Symbol
Function
Function
Performance Class
According to IEC
61557-12
0,2
QV
SA
0,2
EA
0,2
0 to 49999999999
ERV
0 to 49999999999
Frequency
0,05
45 - 65 Hz
Phase current
0,2
20 % Ib I Imax
INc
Neutral current
0,5
20 % Ib I Imax
Voltage
0,2
Umin U Umax
PFA
Power factor
0,5
THDV
0 % to 20 %
THDI
0 % to 100 %
Other Features
Graphical LCD
Language Support
Harmonics Measurement upto 51
Advanced Alarm Settings
Real Time Clock
Measuring Range
Other
Complementary
Characteristics
RS 485
Stranded:
Solid:
Ambient Conditions
Operating Temperature
Storage Temperature
Relative Humidity (no condensation)
Communication and Others
Modbus RTU
Battery
Real Time Clock
Standarts in Compliance
Safety requirements for electrical equipment
for measurement, control, and laboratory use
*
*
3 Phase
95-272 V AC
95-272 V AC
85-265 V AC
1-12 Selectable
1-5000 A
1-5000 A
3P4W
Relay
0,80--1,00 Inductive or Capacitive
0.2
0.2
0.5
512
< 10VA
*
*
3 Phase
95-272 V AC
95-272 V AC
85-265 V AC
1-24 Selectable
1-5000 A
1-5000 A
3P4W
Relay
0,80--1,00 Inductive or Capacitive
0.2
0.2
0.5
512
< 10VA
*
*
1 Phase
95-272 V AC
95-272 V AC
85-265 V AC
1-12 Selectable
1-5000 A
1-5000 A
3P4W
Relay
0,80--1,00 Inductive or Capacitive
0.2
0.2
0.5
512
< 10VA
*
*
1 Phase
95-272 V AC
95-272 V AC
85-265 V AC
1-24 Selectable
1-5000 A
1-5000 A
3P4W
Relay
0,80--1,00 Inductive or Capacitive
0.2
0.2
0.5
512
< 10VA
*
*
1 Phase
95-272 V AC
95-272 V AC
85-265 V AC
1-8 Selectable
1-5000 A
1-5000 A
3P4W
Relay
0,80--1,00 Inductive or Capacitive
0.2
0.2
0.5
512
< 10VA
Upto 51st
*
*
*
Upto 51st
*
*
*
Upto 51st
*
*
*
Upto 51st
*
*
*
Upto 51st
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
6A
0.01-6A
300 V Cat II
2 kV
<0.2 VA
100 A
25,6 kHz
12
2A
250 VAC
1250 VA
2
4A
250 VAC
1000 VA
1
85 - 265 VAC
24
2A
250 VAC
1250 VA
2
4A
250 VAC
1000 VA
1
85 - 265 VAC
12
2A
250 VAC
1250 VA
2
4A
250 VAC
1000 VA
1
85 - 265 VAC
24
2A
250 VAC
1250 VA
2
4A
250 VAC
1000 VA
1
85 - 265 VAC
8
2A
250 VAC
1250 VA
2
4A
250 VAC
1000 VA
1
85 - 265 VAC
0,670 kg
IP 40 front, IP 20 rear
Panel Mount
W144xH144xD78
0,765 kg
IP 40 front, IP 20 rear
Panel Mount
W144xH144xD78
0,653 kg
IP 40 front, IP 20 rear
Panel Mount
W144xH144xD78
0,750 kg
IP 40 front, IP 20 rear
Panel Mount
W144xH144xD78
0,415 kg
IP 40 front, IP 20 rear
Panel Mount
W96xH96xD72
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
300 VAC CAT III acc. to IEC 61010-1 300 VAC CAT III acc. to IEC 61010-1
Dimensions (mm)
58.0
137
7.0
144
144
Wiring Diagrams
Gen Input
Gen Input
Product Code
Product Name
Product Description
601400
Etor-4
601401
Etor-2
Technical Specifications
Supply
Network Features
6 Remote Connections
Configuration via Web Interface
DHCP (Automatic IP Assignment)
ARP
Ping blocking
Serial Communication
Supports Up To 64 Devices
Baudrate: 300, 600, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200
Stop Bit and Parity Bit Settings
USB
Supported Protocols
MODBUS RTU
MODBUS ASCII
MODBUS TCP
MODBUS RTU via TCP
MODBUS ASCII via TCP
Protocol Conversions
ETOR is capable of performing conversions between the serial and Ethernet data by running in server or client modes.
Server Mode
When running in the server mode, ETOR converts the MODBUS TCP, MODBUS RTU over TCP and MODBUS ASCII over
TCP queries to MODBUS RTU and MODBUS ASCII queries and transmits these queries to the serial devices. It converts the
responses it receives to query protocols and transmits them to the querying device (master).
Query Side
Response Side
Physical Port
Ethernet
Physical Port
Serial
Protocol
MODBUS TCP
Protocol
MODBUS RTU
MODBUS ASCII
Client Mode
When running in the client mode, ETOR converts the MODBUS RTU and MODBUS ASCII queries to MODBUS TCP, MODBUS
RTU over TCP and MODBUS ASCII over TCP queries and transmits these queries to the remote devices connected to the
Internet or the local network. The responses received from the devices, convert the query protocols and transmit them to the
querying device (master).
Query Side
Response Side
Physical Port
Serial
Physical Port
Ethernet
Protocol
MODBUS RTU
Protocol
MODBUS TCP
MODBUS ASCII