Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

GE Healthcare

Lullaby
Phototherapy System
Because every baby deserves a high standard of care

Lullaby Phototherapy

Better for baby. More convenient for you.


What if you could specify a phototherapy system that would
meet all of your requirements for clinical quality, versatility,
and ease of use?
Now you can.
The Lullaby Phototherapy System from GE Healthcare is a
unique device for treating indirect hyperbilirubinemia in
newborns that combines a high level of clinical performance
with a simple, flexible design that improves workflow
efficiency and can help keep costs down.
In short its phototherapy that makes sense for todays
healthcare demands.

Designed to meet high clinical standards


Many overhead phototherapy systems have serious drawbacks
from a clinical perspective, including low irradiance levels
and scattered, unfocused coverage. The Lullaby Phototherapy
System was designed specifically to overcome these
impediments to provide more effective newborn care.
The Lullaby Phototherapy Systems blue light delivers healing
phototherapy that meets internationally recognized clinical
guidelines, such as the recommendations of the American
Academy of Pediatrics* including the following critical
specifications:

Performance Factors

Clinical Guideline

Lullaby Phototherapy System

Light Intensity

Irradiance level at least 30 Wcm-2nm-1 30 Wcm-2nm-1 @ 35 cm


In comparison, many other overhead phototherapy
systems provide a low irradiance level of
< 18 Wcm-2nm-1

Light Spectrum

Wavelength between 430-490 nm

450-475 nm (peak of 458nm matching the peak


absorption wavelength at which bilirubin is
broken down)
Instead of scattered light, Lullaby Phototherapy
Systems compact fluorescent lights deliver the
highly focused blue light preferred for medical
therapy.

Surface Area Coverage

Large surface area to combat


extremely high bilirubin levels

Lullaby Phototherapy Systems light covers a


greater area of babys mattress than many other
overhead phototherapy systems.

Distance

Distance between infant and light


source is critical to spectral
irradiance level

Lullaby Phototherapy System enables vertical


light adjustment from 1190-1650 mm from
ground level to achieve optimal source-infant
distance. (35 cm or greater)

* American Academy of Pediatrics, clinical practice guideline, subcommittee on hyperbilirubinemia: Management of hyperbilirubinemia in the newborn infant 35 or more
weeks of gestation, 2004; 297-316.

Bring the light to baby

A long, cost-effective life

The Lullaby Phototherapy System is a highly versatile


device that can be used in any clinical setting where
phototherapy is needed, including well-baby nurseries,
NICU, and PICU. The stand has a vertical light adjustment
that enables easy positioning over incubators, radiant
warmers, bassinets, or open beds. This versatility makes
Lullaby Phototherapy System a highly practical choice
to meet your phototherapy needs wherever and
whenever they occur.

The Lullaby Phototherapy System is exceptionally durable


and easy to maintain. GE Healthcare equipment is known
for its robust design and this system meets all IEC and EMC
regulatory standards for safe operation. The long life of its
robust high intensity lamps upwards of 1000 hours
makes Lullaby Phototherapy System a reliable performer,
day after day, patient after patient. Theres a lamp-life meter
that shows how long the lamps have been operating.

Double intensive phototherapy


If double phototherapy is warranted in an intensive care
setting, Lullaby Phototherapy System, along with
GEs BiliBlanket HighOutput system, can effectively provide
double intensive phototherapy treatment. GE offers a
complete portfolio of phototherapy products for treatment
of hyperbilirubinemia.

At your service
Like all GE Healthcare products, the Lullaby Phototherapy
System is backed by comprehensive service and support.
This includes clinical training to optimize the skills and
efficiency of your staff. You also can take advantage of our
optional multi-year service coverage and extended service
options. From training to service, GE Healthcare stands
behind you to ensure the long-term sustainability of your
equipment investment.

Easy does it
Lullaby Phototherapy System is remarkably simple to
operate, making it as easy to use as switching on a lamp,
even for first-time operators. Its lightweight, slim design
and wheel-brake system make it easy to move across
various floor surfaces and small spaces so you can
easily give therapy to baby.

Specifications
Electrical Specifications

Performance Specifications

100 VA maximum at 120-240 V ~ 50/60 Hz

Spectral Irradiance

High Irradiance Mode:


30 Wcm-2nm-1
(+/- 25%) 18-point check*

Low Irradiance Mode:


20 Wcm-2nm-1
(+/- 25%) 18-point check

Input

0.85 A @ 120 V ~, 50/60 Hz

0.42 A @ 240 V ~, 50/60 Hz

Fuses

T2.0 A, Slow blow type (qty. 2)

Overheat protection

Power cutoff for temp > 90 C

Chassis leakage



Less than 500 A at 264 VAC RMS


(power on) with ground intact for
normal and reverse polarity and
with ground open for normal and
reverse polarity

Ground impedance

Less than 0.1 Ohm from ground pin


of the power inlet module to any
exposed metal surface

Environmental Operations

* Using an Ohmeda Medical BiliBlanket Light Meter


(420-480 nm range)

Wavelength

450-475 nm (peak of 458 nm)

Compact Fluorescent
Light (CFL) Lamps

A typical CFL lamp will run for


1,000 hours before the light
intensity drops to 15%

Acoustic Noise

< 30 dB(A)

Physical Specifications

Ambient temperature

+10 C to +35 C (50 to 95 F)

Overall dimensions
(L x W x H)

710 x 680 x 1650 mm

Humidity

10% to 95% RH non-condensing

Light unit (W x H x L)

460 x 290 x 70 mm

Atmospheric pressure

70 kPa to 106 kPa

Total unit weight

20 kg

Footprint

560 x 590 mm

Height

1190 to 1650 mm

Storage Requirements
Temperature

0 C to +70 C (-40 to 158 F)

Humidity

0% to 100% RH non-condensing

Regulatory Standards

Atmospheric pressure

50 kPa to 106 kPa

IEC Class 1

(continuous operation)




Product TUV certified to the following


standards:
IEC 60601-1-1; IEC 60601-1-2;
IEC 60601-2-50, 2000;
UL 60601-1: 2003;
IEC 60601-1: 1998;
CAN/CSA 601-1M90

EMC ClassA,
CISPR 11, Group 1

Certified under IECEE CB scheme

GE Healthcare
P.O. Box 900, FIN-00031 GE, Finland
Tel. +358 10 394 11 Fax +358 9 146 3310
www.gehealthcare.com

2007 General Electric Company All rights reserved.


General Electric Company reserves the right to make changes in specifications and
features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your GE Representative for the most current information.
BiliBlanket is a registered trademark owned by Datex-Ohmeda, Inc.
Lullaby is a registered trademark owned by GE Healthcare.
GE and GE Monogram are trademarks of General Electric Company.
All other company and product names mentioned may be trademarks
of the companies with which they are associated.

GE imagination at work

GE Healthcare Finland Oy, a General Electric company doing business as


GE Healthcare.

2038979-002-2007.10.-V1.0
0086

You might also like