e - Book - 12p
e - Book - 12p
e - Book - 12p
Company
VISION
We are proud of our excellent designing and engineering capability in
X-ray technology which make us to manufacture the high quality X-ray
machines.
Our product lines are wide from systems and components.
Dongmun is applying the X-ray products to more than 60 countries over
the world, including world famous X-ray Systems manufacturers.
Dongmuns products are welcomed to supply OEM or ODM basis.
HISTORY
1994
1997
1998
1999
2007
Certied, GOST
CE Certied for X-ray Generators
2008
2000
Registered, KFDA
2001
2003
2010
2011
2004
2005
2006
2012
Product
DM-1150RF
DIG-1150
E7254X, E7239X
12M2, 6M2 Selectable
DM-RFT-5
DM-FCT-1
DM-LB50, DM-LBF50
DM-VB-1
12, 9, 6 Selectable
21, 19, 17, 14 Selectable
DM-6150RF
DIG-650
E7252X, E7239X
DM-5125RF
DIG-525
E7239X
Specications
Model
Generator
X-ray Tube
High Tension Cable
Bucky Table
Tube Support Unit
Collimator
Bucky Stand
Option 1
Option 2
DM-1150
DIG-1150
E7254X
12M2, 6M2
Selectable
DM-BT-1
DM-FCT-1
DM-LB50
DM-VB-1
DM-6150
DIG-650
E7252X
DM-5125
DIG-525
E7239X
DM-3125
DIG-325
DM-200
DIG-200
DM-100
DIG-100
DM-BT-1
DM-FCT-1
DM-LB50
DM-VB-1
Product
Specications
U-Arm
(Motor Driving)
Handle Bar
Bucky Device
Moving Table
Option 1
Option 2
DIG-360
DIG-610
DIG-1100
Product
Digital Type
Articulated Type
Mobile Stand
Foldable Stand
Features
- User-friendly operation console and data display
- Calibration program satisfy specication of various X-ray tubes and cable length
- Self-diagnostic mode with error display improving fast fault detection
DM-100MR
DM-200MR
DM-325MR
DM-525MR
Model
DIG-100
DIG-200
DIG-325
DIG-525
Power rating
12.5KW
15KW
32KW
40KW
KV accuracy
40-125(10%+1kV)
40-125(10%+1kV)
40-125(10%+1kV)
40-125(10%+1kV)
mA range
100
50,100,150,200
10 400mA
10 500mA
Time range
5%+1mA
5%+1mA
5%+1mA
5%+1mA
mAs range
1mS-10sec
1mS-10sec
1mS-10sec
Generator
APR
15
216
216
216
Bucky
1 unit standard
2 unit standard
2 unit standard
2 unit standard
220/240V
220/240V
220/240V
220/240V
50/60Hz, 1
50/60Hz, 1
50/60Hz, 1
50/60Hz, 1
10%
10%
10%
10%
1.0X2.0mm
1.0X2.0mm
1.0X2.0mm
1.0X2.0mm
dual focus
dual focus
dual focus
dual focus
Line power
Line compensation
X-ray tube
DM-FCT-1
DM-FCT-1
DM-FCT-1
DM-FCT-1
Lock
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic
Vertical movement
950-1650mm
950-1650mm
950-1650mm
950-1650mm
Transversal movement
600-770mm
600-770mm
600-770mm
600-770mm
Rotating movement
180 at each 90
180 at each 90
180 at each 90
180 at each 90
Angle indication
180
180
180
180
Handle bar
Model
DM-LB50
DM-LB50
DM-LB50
DM-LB50
Tube stand
Collimator
Manual driven
AC24V, 100W
AC24V, 100W
AC24V, 100W
AC24V, 100W
Federal ends
Mobile cart
Transportation
Dimensions
3m X 2
manual stop standard
with cassette box
1170Lx560Wx1870H
3m X 2
manual stop standard
with cassette box
1170Lx560Wx1870H
3m X 2
manual stop standard
with cassette box
1170Lx560Wx1870H
3m X 2
manual stop standard
with cassette box
1170Lx560Wx1870H
Net weight
Approx. 150kg
Approx. 150kg
Approx. 170kg
Approx. 170kg
Option
1. PSU
option
option
option
option
2. Electric transporting
option
option
option
option
3. Wireless type
option
option
4. Flat-panel detector
10 X 12 portable
10 X 12 portable
14 X 17 portable
14 X 17 portable
Product
Detector
DIG-360
Features
- Compact and light weight design.
PC
DIG-1100
DIG-610
Specications
Model
DIG-360
Generator
Maximum Output
Power Rating
Frequency
kVp selection
mA selection
mAs selection
X-ray tube
Anatomical program
Display
35mA/100kV
2.4kW
70kHz
40kV100kV, by 1kV step
0.4mAs-100mAs, 25 steps
Focal spot : 1.2 mm
Memories for 6 selection
7-segment LED read-out
Auto timer, DC24V, 100W
Halogen lamp. 30sec
Light Field Min,
5X5cm@1m SID Max,
35X35cm@65cm SID
SID scale length : 2m
Laser pointer 110/220V AC
110V or 220V AC,50/60Hz, single phase
Collimator
Line Nominal/Phase
Line Voltage
Compensation
Accessories
Dimensions
Weight (Net)
Option
DIG-610
DIG-1100
High Frequency, inverter,
High Frequency, inverter
Capacitor bank
60mA/100kV
100mA/110kV
3.2kW
5.0kW
50kHz
50kHz
40kV100kV, by 1kV step
40kV110kV, by 1kV step
20-100mA, Variable
0.4mAs-100mAs, 25 steps
0.1mAs-100mAs, 38 steps
Focal spot : 2.0 mm
Focal spot : 1.5 mm
Memories for 6 selection
Memories for 750 selection
7-segment LED read-out
LED read-out : kV, mA, mAs/sec,
Auto timer, DC24V, 100W
Auto timer, DC24V, 100W
Halogen lamp. 30sec
Halogen lamp. 30sec
Light Field Min,
Light Field Min,
5X5cm@1m SID Max,
5X5cm@1m SID Max,
35X35cm@65cm SID
35X35cm@65cm SID
SID scale length : 2m
SID scale length : 2m
Laser pointer 110/220V AC
Laser pointer 110/220V AC
110V or 220V AC, 50/60Hz, single phase 110V or 220V AC, 50/60Hz, single phase
10%
Hand Switch, Power cable,
Carrying case, Shoulder band
350L X 250W X 206H mm
Net weight : 12.5kg
10%
Sensor
Features
- Light and small with rechargeable battery enables easy shooting and
keeping everywhere
- Small dose of radiation keeps patients and dentists away from radiation
- High performance Tube and HFG makes sharp and clear images
- Use with digital sensor option as well as chemical lm
10%
DM-70D
Product
Specications
Part
DMX-300
Type
Generator
X-ray Tube
Radiographic Stand
Bucky Device
Automatic Exposure Control
Optional
Line Voltage
Generator
X-ray Tube
XENO-360
Type
Output
KV
mA
ABC
Pulses
Type
Focal Spot
Heat Capacity
Target Angle
Tube Voltage
Type
Field Size
Image Intensier
Resolution
Weight
Power Requirement
Net Weight
Product
DSP-33SQ
DSP-3800
DSP-5000
DSP-8000
Specications
Model
DSP-33SQ
DSP-3800
DSP-5000
DSP-8000
Type
Continue roller
Continue roller
Continue roller
Continue roller
Processing Time
90sec
90/120/180/210sec
90/120/180/210sec
3545cm-115lms/hr
3545cm-150lms/hr
3545cm-200lms/hr
3545cm-300lms/hr
2530cm-200lms/hr
2530cm-190lms/hr
2530cm-280lms/hr
2530cm-420lms/hr
35cm
Developer 8.2L
Developer 10L
Developer 21L
Developer 21L
Fixer 5.2L
Fixer 10L
Fixer 21L
Fixer 21L
Developer 20L
Developer 30L
Developer 60L
Fixer 20L
Fixer 30L
Fixer 60L
220VAC, 50/60Hz
220VAC, 50/60Hz
220VAC, 50/60Hz
220VAC, 50/60Hz
Single Phase
Single Phase
Single Phase
Single Phase
Throughput
Film Size
Tank Capacity
Replenishment
Power
DSP-200
Specication
Model
DSP-200
Film Size
30-350mm in width
Processing Time
4-5minutes
Process Temp
28-34
Tank Capacity
Line Voltage
AC110V/220V/230V
45/60/75/90/120/
120/180/210/240sec
Product
X-ray Generator
DIG-525 / DIG-650
DIG-200
DIG-300
DIG-100
DIG-325
DIG-525
DIG-650
DM-FCT-1,
Floor to Ceiling
DM-FCT-1,
Floor Mounted
DM-MPR-30
DM-500C
Ceiling Suspended
Tube Support Unit
RF Tilting Table
Features
Sturdy and compact design resulting in smooth movements for patients
comport
- Wide range of Fluoroscopic and Radiographic examinations.
- Exceptional range of travel of the table top and spot lm device
- Smooth motor driven tilting from +90 to -15
- +80 to -50cm table top movement allows whole body examinations
- Short distance between the table top and the bucky (6.5cm)
- Front loaded spot lm device
- Fully motorized spot lm device capable of lm divisions
Bucky Table
DM-BT-1
DM-BT-6
DM-FT-1
Description
Dongmun Bucky Table Series are designed for versatile and efficient
radiographic procedures and to reduce patient positioning time and efforts.
They require minimum space for installation and very convenient control.
DM-BT-6, 6-way Floating / Elevating Table Top Bucky Table
DM-BT-1, 4-way Floating Table Top Bucky Table
DM-FT-1, Fixed Table Top Bucky Table
Product
DF, Motor
- Provided with a push button switch timer to automatically switch off the
lamp of light localizer in 30seconds.
DR, Manual
- The lamp of light localizer easily replaceable with minimum error of the same.
- Lamp position and the lamp lament position can be easily adjusted.
- Maximum shutter opening of collimator is 48 48cm at SID 100cm.
- Minimum X-ray eld size at SID 100cm is 0 0cm (Blades overlapped).
- The average illumination of light eld at SID 100cm is 160Lux or more.
DRF, Motor
- The contrast ratio on the light eld edge is 4 : 1 or more, which allows an
easy identication of light eld and its size.
DRP, Manual
Specications
Model
DM-LB10
Type
DR, Manual
DF, Motor
DRF, Motor
DRP, Manual
Maximum kVp
150kVp
100kVp
Projection Lamp
Lamp Timer
Light Projection
Inherent Filtration
1.2mm Al Equivalent
0.5mm Al Equivalent
13,15,18,20,23,25,28,30,36,40cm
Leakage Radiation
Rotation of Radiation
180 Degree
Mounted
Mounted
Electric Requirement
24VAC, 7A
Option
10
DM-LB50
Product
Model
DMC-12DR
DMC-14DR
DMC-17DR
Pixel Matrix
20802560
24002880
30723072
264325mm
360432mm
439.3439.3mm
Pixel Pitch
127um
150um
143um
Resolution
3.9lp/mm
3.3lp/mm
3.5lp/mm
Energy Range
40 150kVp
40 150kVp
40 150kVp
Specications
Sizes
1318cm, 1824cm, 2430cm, 3040cm, 3535cm, 3543cm, 4446cm, 4448cm, 3090cm, 30120cm,
35120cm,
Ratio
5 : 1, 6 : 1, 8 : 1, 10 : 1, 12 : 1, 15 : 1
Density
85LPI, 103 LPI, 150 LPI, 200 LPI, 34LPC, 40LPC, 60LPC
Focal Range
Grid Types
810, 1012, 1114, 1215, 1414, 1417, 171/4187/8, 1818, 1435, 1451,
85LPI (34LPC)
1.75
2.5
3.5
103LPI (40LPC)
1.7
2.5
2.9
3.3
11
Product
Lead Glasses
X-ray Chemicals
Lead Glass
- Optimum image quality
- Flexible polyester base
- Free from static charge
and a scratch
- Compatible with any lms
Cassette Cart
Intensifying Screens
Apron
Thyroid Shield
Ovarian Shield
Gonad Shields
Glove
Apron
- 0.3mm or 0.5mm PB eq
- Shield Size: Single-sized or double-sized
- Velcro and string tie
- Cover: Washable material
- Sized: small, medium, large
12