TW Series - 22mm NEMA Style Pushbuttons: Key Features
TW Series - 22mm NEMA Style Pushbuttons: Key Features
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
Relays & Sockets
Key features:
UL Listed
File No. E68961
CSA Approved
File No. LR21451
Timers
Self cleaning contact mechanisms allow for a wide current rating, 5mA to 10A,
which reduces the need for various contact materials.
When looking for a 22mm switch that is durable, easy to use, and versatile, then
IDECs TW series is your solution.
Contactors
Terminal Blocks
Circuit Breakers
611
22mm - TW Series
Conforming to Standards
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot
lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380,
400/440, 480V)
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights
and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440,
480V)
TV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110,
115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Certificate No.
2030010305027380
Specifications
Timers
Signaling Lights
Operating Temperature
Vibration Resistance
Shock Resistance
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
Mechanical Life
600V
10 Amp
5 mA at 3V AC/DC
Contact Operation
Contact Resistance
Contact Gap
Electrical Reliability
MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Lamp Ratings
Incandescent: 1 W
LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max
1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor)
40 A (40 ms)
Contact Material
Silver
Contact Ratings
Horsepower Rating
Maximum Inrush Current
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Characteristics
Contactors
Terminal Blocks
Approvals
Operational Voltage
Contact Block
Type HW-C/HW-F
600V
10A
AC-15 (A600)
DC-13 (P600)
Circuit Breakers
612
AC50/60Hz
Operational Current
DC
24V
48V
50V
110V
220V
440V
10A
10A
10A
6A
2A
10A
7A
5A
3A
1A
8A
5A
2.2A
1.1A
5A
2A
1.1A
0.6A
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
( )
10
( )
Assembled Pushbuttons
B
Function
Button Color
B: Momentary
O: Maintained
K: Key On/Off Lock
B: Black
R: Red
G: Green
S: Blue
W: White
Y: Yellow
Terminal Style
Bezel Shape
Timers
Blank: Standard
N: Fingersafe (IP20)
Blank: Octagonal
F: Full Shroud
G: Mushroom Shroud
Q: Square
Contact Arrangement
10: 1NO
01: 1NC
20: 2NO
02: 2NC
11: 1NO-1NC 22: 2NO-2NC
1:
2:
3:
4:
Contactors
Button Shape
Flush
Extended
Mushroom Head 29mm
Mushroom Head 40mm
Series Designation
Terminal Blocks
W: TW Series
To be used for interpreting part numbers only, not for part number development.
Circuit Breakers
613
Non-Illuminated Pushbuttons
Style
Flush
Contactors
Contacts
Momentary Action
ABW110-j
ABW101-j
ABW111-j
ABW120-j
ABW102-j
Maintained Action
Color
Code
AOW110-j
AOW101-j
AOW111-j
AOW120-j
AOW102-j
Black
Green
Red
Extended
1NO
1NC
1NO-1NC
2NO
2NC
ABW210-j
ABW201-j
ABW211-j
ABW220-j
ABW202-j
AOW210-j
AOW201-j
AOW211-j
AOW220-j
AOW202-j
Recessed
1NO
1NC
1NO-1NC
2NO
2NC
ABFW110-j
ABFW101-j
ABFW111-j
ABFW120-j
ABFW102-j
AOFW110-j
AOFW101-j
AOFW111-j
AOFW120-j
AOFW102-j
1NO
1NC
1NO-1NC
2NO
2NC
ABFW210-j
ABFW201-j
ABFW211-j
ABFW220-j
ABFW202-j
AOFW210-j
AOFW201-j
AOFW211-j
AOFW220-j
AOFW202-j
29mm
Mushroom Head
1NO
1NC
1NO-1NC
2NO
2NC
ABW310-j
ABW301-j
ABW311-j
ABW320-j
ABW302-j
AOW310-j
AOW301-j
AOW311-j
AOW320-j
AOW302-j
40mm
Mushroom Head
1NO
1NC
1NO-1NC
2NO
2NC
ABW410-j
ABW401-j
ABW411-j
ABW420-j
ABW402-j
AOW410-j
AOW401-j
AOW411-j
AOW420-j
AOW402-j
40mm
Mushroom Head
with Full Shroud
1NO
1NC
1NO-1NC
2NO
2NC
ABGW410-j
ABGW401-j
ABGW411-j
ABGW420-j
ABGW402-j
AOGW410-j
AOGW401-j
AOGW411-j
AOGW420-j
AOGW402-j
Square Flush
1NO
1NC
1NO-1NC
2NO
2NC
ABQW110-j
ABQW101-j
ABQW111-j
ABQW120-j
ABQW102-j
AOQW110-j
AOQW101-j
AOQW111-j
AOQW120-j
AOQW102-j
Square Extended
1NO
1NC
1NO-1NC
2NO
2NC
ABQW210-j
ABQW201-j
ABQW211-j
ABQW220-j
ABQW202-j
AOQW210-j
AOQW201-j
AOQW211-j
AOQW220-j
AOQW202-j
1NO
1NC
1NO-1NC
2NO
2NC
AKW210
AKW201
AKW211
AKW220
AKW202
Circuit Breakers
Terminal Blocks
Timers
Signaling Lights
22mm - TW Series
614
www.IDEC.com
Blue
Yellow
White
22mm - TW Series
Switches & Pilot Devices
Style
Button
Buttons
Part Number
Momentary
Part Number
Round Flush
AOW-100
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
Fingersafe
(IP20), CE
marked
ABW2B-j
AOFW-200
29mm Mushroom
40mm, 29mm
Mushroom Head
1NC
Dummy Block
ABW3B-j
TW-DB
AOW-300
40mm Mushroom
40mm Mushroom
Head with Full Shroud
ABW4B-j
AOGW-400
Square Flush/Extended
ABQW-100
AOQW-100
ABQW2B-j
Color
Code
Black
Green
Red
Blue
Yellow
White
Terminal Blocks
Square Extended
Contactors
ABGW-400
Timers
ABW-300
Round Extended
ABFW-200
1NO
ABW1B-j
Part Number
Style
Round Flush/Extended
ABW-100
Complete Part
Contact Blocks
Style
Maintained
Signaling Lights
Operators
Operator
AKW-200
In place of j specify the button color code from table
Circuit Breakers
615
22mm - TW Series
Signaling Lights
(L)
(B)
(99)
11
(D)
Function
Lamp Voltage
6V:
12V:
24V:
120V:
240V:
Timers
Illumination
Blank: None
L: Illuminated
W: TW Series
Button/Lens Size
3: 29mm Mushroom
4: 40mm Mushroom
Blank: Standard
N: Fingersafe (IP20)
Lens Type
Lamp Type
Contactors
Terminal Blocks
6V AC/DC
12V AC/DC
24V AC/DC
120V AC (LED only)
240V AC (LED only)
Button/Lens Color
Series Designation
Circuit Breakers
(N) R (24V)
Blank: Incandescent
D: LED
Illuminated Circuit
Contact Arrangement
99:
126:
246:
486:
10: 1NO
01: 1NC
20: 2NO
02: 2NC
11: 1NO/1NC 22: 2NO/2NC
To be used for interpreting part numbers only, not for part number development.
616
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Style
Contacts
1NO
1NC
1NO-1NC
2NO
2NC
40mm Pushlock
Turn Reset*
40mm Push-Pull
Code
AVW410-R*
AVW401-R*
AVW411-R*
AVW420-R*
AVW402-R*
Black
Green
Red
AVW310-R*
AVW301-R*
AVW311-R*
AVW320-R*
AVW302-R*
1NO
1NC
1NO-1NC
2NO
2NC
AYW410-j
AYW401-j
AYW411-j
AYW420-j
AYW402-j
AXW410AXW401AXW411AXW420AXW402-
R*
R*
R*
R*
R*
Part Number
Full Voltage
1NO-1NC
2NO
2NC
AVLW49911n-R*-l
AVLW49920n-R*-l
AVLW49902n-R*-l
Transformer
1NO-1NC
2NO
2NC
AVLW3m11n-R*
AVLW3m20n-R*
AVLW3m02n-R*
Full Voltage
1NO-1NC
2NO
2NC
AVLW39911n-R*-l
AVLW39920n-R*-l
AVLW39902n-R*-l
Transformer
1NO-1NC
2NO
2NC
AYLW4 m 11n-k
AYLW4 m 20n-k
AYLW4 m 02n-k
Full Voltage
1NO-1NC
2NO
2NC
AYLW49911n-k-l
AYLW49920n-k-l
AYLW49902n-k-l
40mm Push-Pull
Code
Amber
Green
Red
Blue
White
Voltage
Code
6V AC/DC
6V
12V AC/DC
12V
24V AC/DC
24V
120V AC
240V AC
Code
120VAC
240VAC
480VAC
126
246
486
Code
Incandescent
Blank
LED
D
Terminal Blocks
AVLW4 m 11n-R*
AVLW4 m 20n-R*
AVLW4 m 02n-R*
29mm Pushlock
Turn Reset
Color
Contactors
Transformer
1NO-1NC
2NO
2NC
40mm Pushlock
Turn Reset Type
Timers
Contacts
Yellow
S
W
Style
Blue
White
1NO
1NC
1NO-1NC
2NO
2NC
1NO
1NC
1NO-1NC
2NO
2NC
40mm Pushlock
Key Reset *
Color
Signaling Lights
29mm Pushlock
Turn Reset*
Part Number
Circuit Breakers
617
Signaling Lights
22mm - TW Series
Contacts
Lamp Holder
Operator
Lamp
+ Button or Lens =
Operators
Style
Buttons
Contact Blocks
Part Number
Style
Non-Illuminated Illuminated
Part Number
Style
LED
AVW4B-R*
AVW-300
AVLW3-0600
Incandescent
AVW3B-R*
AYW-400
Voltage
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
AYLW4-0600
40mm Push-Pull
Timers
Complete Part
40mm Pushlock
Key Reset
Contactors
AXW4B-R*
Circuit Breakers
Terminal Blocks
618
www.IDEC.com
Color
Code
Black
Green
Red
Blue
White
Yellow
Code
Amber
Green
Red
Blue
White
22mm - TW Series
Switches & Pilot Devices
Style
Part Number
Standard
Engravable
Description
AVLW3BLU-R*
Fingersafe
Half Size Transformer
AVLW4LU-R*
AVLW4BLU-R*
1. In place of k, specify the lens color code from table on previous page.
2. *Available only in red
3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert.
Application
TW-T246B
480V AC
TW-T486B
120V AC
TW-F126B
240V AC
TW-F246B
480V AC
TW-F486B
120V AC
TW-T126SB
240V AC
TW-T246SB
Standard
TW-DA1B
Fingersafe
TW-DA1FB
Standard
HW-DA1B
Fingersafe
HW-DA1FB
Part Number
Timers
TW-T126B
240V AC
AYLW4LU-k
120V AC
Signaling Lights
Part Number
TW-LH1
All Transformers step down to 6V (use 6V lamp).
TW-LH2
HW-LH3
Contact Blocks
Style
Standard Exposed Screw
Lead Holder
Part Number
1NO
1NC
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
Terminal Blocks
Contactors
Dummy Block
TW-DB
Circuit Breakers
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
619
22mm - TW Series
Signaling Lights
(Q)
(B)
(99)
(D) R (24V)
Function
Lamp Voltage
6V:
12V:
24V:
120V:
240V:
Series Designation
W: TW Series
1: Flat
2: Dome
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Lens Type
Lamp Type
Blank: Incandescent
D: LED
Bezel Shape
Lens Shape
Illumination Circuit
99:
126:
246:
486:
Circuit Breakers
Terminal Blocks
Contactors
Timers
P: Pilot Light
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. All transformers step down to 6V.
620
www.IDEC.com
6V AC/DC
12V AC/DC
24V AC/DC
120V AC (LED only)
240V AC (LED only)
22mm - TW Series
Switches & Pilot Devices
Style
Type
Voltage
Part Number
Color
Code
Transformer
120VAC
240VAC
480VAC
APW1126m-k
APW1246m-k
APW1486m-k
Amber
Green
Red
APW199m-k-l
Round Flat
Full Voltage
120VAC
240VAC
480VAC
APW2126m-k
APW2246m-k
APW2486m-k
Full Voltage
APW299m-k-l
Transformer
120VAC
240VAC
480VAC
APQW1B126m-k
APQW1B246m-k
APQW1B486m-k
Dome
Full Voltage
APQW1B99m-k-l
Yellow
Code
6V AC/DC
6V
12V AC/DC
12V
24V AC/DC
24V
120V AC
240V AC
Square Flat
S
W
Signaling Lights
Transformer
Blue
White
Code
Incandescent
Blank
LED
Timers
Contactors
Terminal Blocks
Circuit Breakers
621
Signaling Lights
22mm - TW Series
Operator
Lamp
Lens
Operators
Style
Lamps
Part Number
Complete Part
Style
LED
APW-199
Incandescent
Square
UPQW-199
Timers
Voltage
Part Number
Color
Code
6V AC/DC
LSTD-6k
Amber
12V AC/DC
LSTD-1k
Green
24V AC/DC
LSTD-2k
Red
120V AC
LSTD-H2k
Blue
240V AC
LSTD-M4k
White
6V AC/DC
IS-6
Yellow
12V AC/DC
IS-12
24V AC/DC
IS-24
Part Number
Standard
Description
Standard
Engravable
Dome
Contactors
APW2LU-k
Fingersafe
Round Flat
APW1LU-k
APW1BLU-k
APQW1BLU-k
Square Flat
Circuit Breakers
622
Transformers
Style
Style
Lenses
Terminal Blocks
Round Dome/Flat
www.IDEC.com
Part Number
120V AC
TW-T126B
240V AC
TW-T246B
480V AC
TW-T486B
120V AC
TW-F126B
240V AC
TW-F246B
480V AC
TW-F486B
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
(F)
(B)
99
11
Function
(N) R (24V)
Lamp Voltage
L: Momentary Action
OL: Maintained Action
Timers
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC (LED only)
240V: 240V AC (LED only)
Bezel Shape
Lens Code
W: TW series
Lens Shape/Size
2: Standard Extended (round or square)
3: 29mm Mushroom
4: 40mm Mushroom
Contactors
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Series Designation
Lens Type
Blank: Standard (ribbed)
B: Engravable (smooth with insert)
Lamp Type
Terminal Blocks
Blank:
Incandescent Lamp
D: LED Lamp
Illumination Circuit
99:
126:
246:
486:
(D)
Contact Arrangement
10: 1NO
20: 2NO
11: 1NO-1NC
01: 1NC
02: 2NC
22: 2NO-2NC
Circuit Breakers
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. Transformers step down to 6V.
623
22mm - TW Series
Style
Signaling Lights
Extended Lens
Contacts
Transformer
Timers
Contactors
Terminal Blocks
Square Extended
ALW2 m 11n-k
ALW2 m 20n-k
ALW2 m 02n-k
Maintained
AOLW2 m 11n-k
AOLW2 m 20n-k
AOLW2 m 02n-k
Full Voltage
ALW29911n-k-l
ALW29920n-k-l
ALW29902n-k-l
AOLW29911n-k-l
AOLW29920n-k-l
AOLW29902n-k-l
Transformer
1NO-1NC
2NO
2NC
ALFW2 m 11n-k
ALFW2 m 20n-k
ALFW2 m 02n-k
AOLFW2 m 11n-k
AOLFW2 m 20n-k
AOLFW2 m 02n-k
Transformer
Full Voltage
Momentary
1NO-1NC
2NO
2NC
Full Voltage
1NO-1NC
2NO
2NC
Part Number
Transformer
1NO-1NC
2NO
2NC
1NO-1NC
2NO
2NC
ALFW29911n-k-l
ALFW29920n-k-l
ALFW29902n-k-l
ALW3 m 11n-k
ALW3 m 20n-k
ALW3 m 02n-k
AOLFW29911n-k-l
AOLFW29920n-k-l
AOLFW29902n-k-l
AOLW3 m11n-k
AOLW3 m20n-k
AOLW3 m 02n-k
1NO-1NC
2NO
2NC
ALW39911n-k-l
ALW39920n-k-l
ALW39902n-k-l
AOLW39911n-k-l
AOLW39920n-k-l
AOLW39902n-k-l
1NO-1NC
2NO
2NC
ALW4 m 11n-k
ALW4 m 20n-k
ALW4 m 02n-k
AOLW4 m11n-k
AOLW4 m20n-k
AOLW4 m 02n-k
Full Voltage
1NO-1NC
2NO
2NC
ALW49911n-k-l
ALW49920n-k-l
ALW49902n-k-l
AOLW49911n-k-l
AOLW49920n-k-l
AOLW49902n-k-l
Transformer
1NO-1NC
2NO
2NC
ALQW2B m11n-k
ALQW2B m20n-k
ALQW2B m02n-k
AOLQW2B m11n-k
AOLQW2B m20n-k
AOLQW2B m02n-k
Full Voltage
1NO-1NC
2NO
2NC
ALQW2B9911n-k-l
ALQW2B9920n-k-l
ALQW2B9902n-k-l
AOLQW2B9911n-k-l
AOLQW2B9920n-k-l
AOLQW2B9902n-k-l
Circuit Breakers
1. In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow.
2. In place of l, specify the Full Voltage Code (lamp voltage) (see table).
3. In place of m, specify the Transformer Voltage Code (see table).
4. In place of n, specify the Lamp Type Code from table.
5. For sub-assembly part numbers, see next page.
6. For accessories, see page 643.
7. For dimensions, see page 645.
8. Light is independent of switch position.
9. Yellow pushbutton comes with white LED.
624
www.IDEC.com
Color
Code
Amber
Green
Red
Blue
White
Yellow
Code
6V AC/DC
6V
12V AC/DC
12V
24V AC/DC
24V
120V AC
240V AC
Code
120VAC
126
240VAC
246
480VAC
486
Code
Incandescent
Blank
LED
22mm - TW Series
Switches & Pilot Devices
Contacts
Lamp Holder
Operator
Lamp
Lens
Complete Part
Operators
Signaling Lights
Lamps
Style
Style
Part Number
Momentary
Maintained
LED
ALW-0600
Extended
ALFW-0600
29mm/40mm
Mushroom
AOLFW-0600
ALW3-0600
AOLW3-0600
Incandescent
Part Number
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
Extended with
Full Shroud
AOLW-0600
Voltage
6V AC/DC
Application
Lenses
Style
TW-LH1
TW-LH2
HW-LH3
Part Number
Standard
Engravable
Round Extended
ALW2LU-k
ALW2BLU-k
29mm
Mushroom Head*
ALW3LU-k
ALW3BLU-k
Contactors
Lead Holder
ALW4LU-k
ALW4BLU-k
Terminal Blocks
40mm
Mushroom Head*
Part Number
Timers
ALQW-2B0600
Square/Extended
ALQW2BLU-k
Code
Color
Code
Amber
Blue
Green
White
Red
Yellow
Circuit Breakers
1. In place of k, specify the lens color code from table on the bottom right.
2. *Mushroom lens not available in yellow.
3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an
engravable insert.
Color
625
Signaling Lights
22mm - TW Series
Contact Blocks
Style
Standard Exposed Screw
Style
Part Number
1NO
1NC
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
Description
Fingersafe
Part Number
120V AC
TW-T126B
240V AC
TW-T246B
480V AC
TW-T486B
120V AC
TW-F126B
240V AC
TW-F246B
480V AC
TW-F486B
TW-T126SB
240V AC
TW-T246SB
Standard
TW-DA1B
Fingersafe
TW-DA1FB
Standard
HW-DA1B
Fingersafe
HW-DA1FB
Dummy Block
TW-DB
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
Timers
Circuit Breakers
Terminal Blocks
Contactors
626
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
Relays & Sockets
(1)
(L)
20
(N) 304
Function
Circuit Number
S: Selector Switch
Series Designation
Blank: standard
N: Fingersafe (IP20)
Number of Positions
2: 2-Position
3: 3-Position
4: 4-Position
5: 5-Position
Blank: Maintained
1: Spring return from Right (2 or 3 position)
2: Spring return from Left (2 or 3 position)
3: 2-Way spring return from Left and Right
(3 position only)
Contactors
10: 1NO
01: 1NC
20: 2NO
02: 2NC
40: 4NO
04: 4NC
11: 1NO-1NC 22: 2NO-2NC
Terminal Blocks
1.
2.
3.
4.
Timers
W: TW Series
Use only when interpreting part numbers. Do not use for developing part numbers.
Custom contact configurations available.
Custom key removable codes available.
Portions of part number inside ( ) are optional.
Circuit Breakers
627
Part Number
Operator
Position
Spring Return
from Left
Mounting
Spring Return
from Right
Contact
Maintained
1NO
1
2
O
O
X
O
Knob
Lever
Key
ASW210
ASW2L10
ASW2K10
ASW2110
ASW21L10
ASW21K10
ASW2210
ASW22L10
ASW22K10
1NC
1
2
X
O
O
O
Knob
Lever
Key
ASW201-116
ASW2L01-116
ASW2K01-116
ASW2101-116
ASW21L01-116
ASW21K01-116
ASW2201-116
ASW22L01-116
ASW22K01-116
1NO
1NC
1
2
X
O
O
X
Knob
Lever
Key
ASW211
ASW2L11
ASW2K11
ASW2111
ASW21L11
ASW21K11
ASW2211
ASW22L11
ASW22K11
2NO
1
2
O
O
X
X
Knob
Lever
Key
ASW220
ASW2L20
ASW2K20
ASW2120
ASW21L20
ASW21K20
ASW2220
ASW22L20
ASW22K20
2NC
1
2
X
X
O
O
Knob
Lever
Key
ASW202-104
ASW2L02-104
ASW2K02-104
ASW2102-104
ASW21L02-104
ASW21K02-104
ASW2202-104
ASW22L02-104
ASW22K02-104
2NO
2NC
1
2
3
4
O
X
O
X
X
O
X
O
Knob
Lever
Key
ASW222
ASW2L22
ASW2K22
ASW2122
ASW21L22
ASW21K22
ASW2222
ASW22L22
ASW22K22
2NO
2NC
1
2
3
4
O
O
X
X
X
X
O
O
Knob
Lever
Key
ASW222-111
ASW2L22-111
ASW2K22-111
ASW2122-111
ASW21L22-111
ASW21K22-111
ASW2222-111
ASW22L22-111
ASW22K22-111
Circuit Breakers
Terminal Blocks
Contactors
Timers
Signaling Lights
22mm - TW Series
628
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Part Number
Spring Return from Right
Mounting
Maintained
Contact
Operator Position
2NO
1
2
X
O
O
O
O
X
Knob
Lever
Key
ASW320
ASW3L20
ASW3K20
ASW3120
ASW31L20
ASW31K20
ASW3220
ASW32L20
ASW32K20
ASW3320
ASW33L20
ASW33K20
2NC
1
2
O
X
X
X
X
O
Knob
Lever
Key
ASW302
ASW3L02
ASW3K02
ASW3102
ASW31L02
ASW31K02
ASW3202
ASW32L02
ASW32K02
ASW3302
ASW33L02
ASW33K02
2NO
2NC
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
Knob
Lever
Key
ASW322
ASW3L22
ASW3K22
ASW3122
ASW31L22
ASW31K22
ASW3222
ASW32L22
ASW32K22
ASW3322
ASW33L22
ASW33K22
2NO
2NC
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
Knob
Lever
Key
ASW322-309
ASW3L22-309
ASW3K22-309
ASW3122-309
ASW31L22-309
ASW31K22-309
ASW3222-309
ASW32L22-309
ASW32K22-309
ASW3322-309
ASW33L22-309
ASW33K22-309
2NO
2NC
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
Knob
Lever
Key
ASW322-310
ASW3L22-310
ASW3K22-310
ASW3122-310
ASW31L22-310
ASW31K22-310
ASW3222-310
ASW32L22-310
ASW32K22-310
ASW3322-310
ASW33L22-310
ASW33K22-310
4NO
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Knob
Lever
Key
ASW340
ASW3L40
ASW3K40
ASW3140
ASW31L40
ASW31K40
ASW3240
ASW32L40
ASW32K40
ASW3340
ASW33L40
ASW33K40
4NC
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Knob
Lever
Key
ASW304
ASW3L04
ASW3K04
ASW3104
ASW31L04
ASW31K04
ASW3204
ASW32L04
ASW32K04
ASW3304
ASW33L04
ASW33K04
Signaling Lights
Relays & Sockets
Timers
X
O
O
O
Part Number
4
2NO
2NC
1
2
3
4
X
O
O
O
O
X
O
O
O
O
X
O
O
O
O
X
Knob
Lever
ASW422-411
ASW4L22-411
Maintained
Operator Position
Mounting
1
2
3
4
Style
Contact
Operator Position
Mounting
2NO
2NC
Maintained
O
X
O
O
O
O
O
O
Part Number
O
O
X
O
O
O
O
X
2
1
Knob
Lever
ASW522-501
ASW5L22-501
Terminal Blocks
Contact
Style
Contactors
1. The truth table indicates the operating position of contact block when the operator is switched to that position.
X = On (closed contacts)
O = Off (open contacts)
X
X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions.
2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately.
3. Every key selector switch uses an identical key. The key is removable in any maintained position.
4. Custom contact configurations are available, see page 635.
Circuit Breakers
629
Signaling Lights
22mm - TW Series
Operator
Knob or Lever*
Color Insert*
Complete Part
Operators
Positions
ASW200
ASW2100
ASW2200
Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3
ASW300-1
ASW300-2
ASW300-3
ASW3100-1
ASW3100-2
ASW3200-1
ASW3200-2
ASW3300-1
ASW3300-2
ASW400
ASW400-1
ASW500
ASW500-1
Maintained
ASW2K00
Contactors
1.
2.
3.
4.
ASW21K00
ASW22K00
Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3
ASW3K00-1
ASW3K00-2
ASW3K00-3
ASW31K00-1
ASW31K00-2
ASW32K00-1
ASW32K00-2
ASW33K00-1
ASW33K00-2
Color
Code
Black*
Blue
Green
Red
Yellow
White
Part Number
Knob
ASWHHY-j
Lever
ASWHHL-j
Color
Insert
TW-HC1-j
Contact Blocks
Style
Standard Exposed
Screw
Fingersafe (IP20), CE
marked
Part Number
1NO
1NC
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
Dummy Block
Replacement Parts
AKW2B-B
TW-DB
630
Style
Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position.
Locking rings are included with all operators. Order knobs, levers, and color inserts separately.
Different cams produce different contact actions. For details, see page 635.
Key switch operator supplied with black sleeve.
Circuit Breakers
Part Number
Knob/Lever
Key
Description
Maintained
Terminal Blocks
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
SL
(2)
99
11
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC (LED only)
240V: 240V AC (LED only)
Series Designation
W: TW series
Number of Positions
Timers
2: 2-Position
3: 3-Position
Contactors
Illumination Circuit
99:
126:
246:
486:
Function
Terminal Blocks
Lamp Type
Blank: Incandescent Lamp
D: LED Lamp
Contact Arrangement
01: 1NC
02: 2NC
04: 4NC
22: 2NO-2NC
Circuit Breakers
10: 1NO
20: 2NO
40: 4NO
11: 1NO-1NC
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. All transformers step down to 6V (use 6V lamp).
631
Style
Part Number
Spring Return from Right
Mounting
Maintained
Contact
Operator
Position
1NO
1NC
1
2
O
X
X
O
Transformer
Full Voltage
ASLW2 j 11m-k
ASLW29911m-k-l
ASLW21 j 11m-k
ASLW219911m-k-l
ASLW22 j 11m-k
ASLW229911m-k-l
2NO
1
2
O
O
X
X
Transformer
Full Voltage
ASLW2 j 20m-k
ASLW29920m-k-l
ASLW21 j 20m-k
ASLW219920m-k-l
ASLW22 j 20m-k
ASLW229920m-k-l
2NC
1
2
X
X
O
O
Transformer
Full Voltage
ASLW2 j 02m-104-k
ASLW29902m-104-k-l
ASLW21 j 02m-104-k
ASLW219902m-104-k-l
ASLW22 j 02m-104-k
ASLW229902m-104-k-l
2NO
2NC
1
2
3
4
O
X
O
X
X
O
X
O
Transformer
Full Voltage
ASLW2 j 22m-k
ASLW29922m-k-l
ASLW21 j 22m-k
ASLW219922m-k-l
ASLW22 j 22m-k
ASLW229922m-k-l
Lamp
Circuit Type
Style
Voltage
Code
120VAC
126
240VAC
246
480VAC
486
Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right
Color
Code
Amber
Green
Red
Blue
White
Yellow
Part Number
Spring Return From Right
Mounting
Maintained
Contact
Operator Position
2NO
1
2
X
O
O
O
O
X
Transformer
Full Voltage
ASLW3 j 20m-k
ASLW39920m-k-l
ASLW31 j 20m-k
ASLW319920m-k-l
ASLW32 j 20m-k
ASLW329920m-k-l
ASLW33 j 20m-k
ASLW339920m-k-l
2NC
1
2
O
X
X
X
X
O
Transformer
Full Voltage
ASLW3 j 02m-k
ASLW39902m-k-l
ASLW31 j 02m-k
ASLW319902m-k-l
ASLW32 j 02m-k
ASLW329902m-k-l
ASLW33 j 02m-k
ASLW339902m-k-l
2NO
2NC
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
Transformer
Full Voltage
ASLW3 j 22m-k
ASLW39922m-k-l
ASLW31 j 22m-k
ASLW319922m-k-l
ASLW32 j 22m-k
ASLW329922m-k-l
ASLW33 j 22m-k
ASLW339922m-k-l
2NO
2NC
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
Transformer
Full Voltage
ASLW3 j 22m-309-k
ASLW39922m-309-k-l
ASLW31 j 22m-309-k
ASLW319922m-309-k-l
ASLW32 j 22m-309-k
ASLW329922m-309-k-l
ASLW33 j 22m-309-k
ASLW339922m-309-k-l
2NO
2NC
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
Transformer
Full Voltage
ASLW3 j 22m-310-k
ASLW39922m-310-k-l
ASLW31 j 22m-310-k
ASLW319922m-310-k-l
ASLW32 j 22m-310- k
ASLW329922m-310- k -l
ASLW33 j 22m-310-k
ASLW339922m-310-k-l
4NO
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Transformer
Full Voltage
ASLW3 j 40m-k
ASLW39940m-k-l
ASLW31 j 40m-k
ASLW319940m-k-l
ASLW32 j 40m-k
ASLW329940m-k-l
ASLW33 j 40m-k
ASLW339940m-k-l
4NC
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Transformer
Full Voltage
ASLW3 j 04m-k
ASLW39904m-k-l
ASLW31 j 04m-k
ASLW319904m-k-l
ASLW32 j 04m-k
ASLW329904m-k-l
ASLW33 j 04m-k
ASLW339904m-k-l
Lamp
Circuit Type
Circuit Breakers
Terminal Blocks
Contactors
Timers
Signaling Lights
22mm - TW Series
632
Code
Lamp
Code
6V AC/DC
6V
Incandescent
Blank
12V AC/DC
12V
LED
24V AC/DC
24V
120V AC
240V AC
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Contact Block
Operator
+ Lamp/Lead Holder +
Lamp
Lens
Complete Part
Operators
Style
Lamps
Positions
Description
Part Number
Maintained
ASLW200
ASLW2100
ASLW2200
ASLW300-2
ASLW3200-1
ASLW3300-1
ASLW3100-2
ASLW3200-2
ASLW3300-2
Different cams produce different contact action. For details, see Contact Arrangements
on page 635.
Lenses (Knobs)
ASLWLU-k
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
Code
Amber
Green
Red
Blue
White
Yellow
Contactors
Part Number
Voltage
Timers
ASLW3100-1
Knob
Incandescent
ASLW300-3
Style
LED
ASLW300-1
Maintained, cam 1
Maintained, cam 2
Maintained, cam 3
Style
Signaling Lights
*Full voltage units use a full voltage adaptor (TW-DA1B) instead of a transformer.
Terminal Blocks
Circuit Breakers
633
Signaling Lights
22mm - TW Series
Part Number
1NO
1NC
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
Description
Fingersafe
Part Number
120V AC
TW-T126B
240V AC
TW-T246B
480V AC
TW-T486B
120V AC
TW-F126B
240V AC
TW-F246B
480V AC
TW-F486B
TW-T126SB
240V AC
TW-T246SB
Standard
TW-DA1B
Fingersafe
TW-DA1FB
Standard
HW-DA1B
Fingersafe
HW-DA1FB
Dummy Block
TW-DB
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
Application
Part Number
Contactors
TW-LH1
TW-LH2
HW-LH3
Circuit Breakers
Terminal Blocks
Lead Holder
634
www.IDEC.com
22mm - TW Series
Contact Arrangement
Circuit Number
* N/D = No designation
required
Contact Block
Mounting Position
Operator Position
Truth table indicates the operating position of contact block
when operator is switched to
that position.
Position or mounting
contact blocks on operator
N/D
1NC
116
1NO
1NC
103
600
1NO-EM
1NC-LB
2NO
N/D
2NC
104
2NO
2NC
HW-C10
TW-DB
HW-C01
TW-DB
HW-C10
HW-C01
HW-C01
HW-C10
HW-C10R
HW-C01R
HW-C01R
HW-C10R
HW-C10
HW-C10
HW-C01
HW-C01
HW-C10
HW-C01
HW-C10
HW-C01
HW-C10
HW-C10
HW-C01
HW-C01
Spring Ret.
from Rt.
L
Spring Ret.
from Lt.
L
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Circuit Breakers
111
Maintained
Description
Terminal Blocks
N/D
Contact Block
Part Number
Contactors
601
Timers
N/D
1NO
Mounting
Position
Contact Block
Part Number
Signaling Lights
Contact
Circuit
Number
Operator
Position
635
22mm - TW Series
Contact Arrangement Chart: 3-Position Selector Switches
Style
Contact
Circuit
Number
Signaling Lights
202
203
1NO
1NC
302
303
N/D
2NO
301
Timers
304
2NC
N/D
Contactors
N/D
210
2NO
2NC
Terminal Blocks
308
309
Circuit Breakers
310
Mounting
Position
Contact Block
Part Number
HW-C10
HW-C01
HW-C01
HW-C10
HW-C10
HW-C01
HW-C01
HW-C10
HW-C10
HW-C10
HW-C10
HW-C10
HW-C01
HW-C01
HW-C01
HW-C01
HW-C10
HW-C10
HW-C01
HW-C01
HW-C01
HW-C10
HW-C01
HW-C10
Description
Maintained
L
HW-C10
HW-C01
HW-C10
HW-C01
HW-C10
HW-C01
HW-C01
HW-C10
HW-C01
HW-C10
HW-C01
HW-C10
Spring Return
from Right
L
Spring Return
from Left
L
Two-Way
L
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
1. Each operator sub-assembly is available as a -1 and a -2 for 3-position selector switches. The internal cam of a -1 is different from that of a -2. This results in designated combinations of open
and closed contacts in the various operator positions.
2. N/D = No circuit number designation required in assembled part number.
3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions.
636
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Contact
Circuit
Number
4NO
305
4NC
314
Description
Maintained
L
HW-C10
HW-C10
HW-C10
HW-C10
HW-C10
HW-C10
HW-C10
HW-C10
HW-C01
HW-C01
HW-C01
HW-C01
HW-C01
HW-C01
HW-C01
HW-C01
Spring Return
from Left
L
Two-Way
L
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
N/D
Contact Block
Part Number
Signaling Lights
N/D
Mounting
Position
Spring Return
from Right
Timers
1. Each operator sub-assembly is available as a -1 and a -2 for 3-position selector switches. The internal cam of a -1 is different from that of a -2. This results in designated combinations of open
and closed contacts in the various operator positions.
2. N/D = No circuit number designation required in assembled part number.
3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions.
Contactors
Terminal Blocks
Circuit Breakers
637
22mm - TW Series
Mounting Positions
Step 1
Signaling Lights
3
1
Step 2
How many contacts should there be?
# of isolated contacts
(maximum 6)
Step 3
Fill in the Truth Table
(X = closed, 0 = open)
Knob Position
1
1
Contacts
Timers
2
3
4
5
6
Contactors
Step 4
If building a 2 position selector, skip this step. (2 position selectors have only one cam)
If building a 3, 4, or 5 position selector, determine appropriate cam as follows:
Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page).
Repeat for all rows. The user must find one operator that contains all rows from above table.
Record the operator cam version.
Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. L and R refer to mounting on left or right
side of operator as viewed from the front of the panel.
Step 6
Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 627 or 631. In place of the
Circuit Number indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where 3 is the cam number, and contact arrangement OELCXX
calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations.
Circuit Breakers
Terminal Blocks
Step 5
Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance.
1. For Operator Truth Tables, see next page.
638
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
ASW200
ASLW200
ASW2K00
HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
Operator
Position
Left
Right
Contact
Contact
HW-C10
(NO)
ASW300-1
ASW3K00-1
ASLW300-1
HW-C01
(NC)
HW-C01R
(NC-LB)
Contact
ASW300-2
ASW3K00-2
ASLW300-2
HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
HW-C10
(NO)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
Mounting
Position
Center
Right
ASW400-1
Left
Center
Right
Left
Center
Right
HW-C01
(NC)
HW-C10R
(NO-EM)
ASW500
HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
Contact
Operator Position
Mounting
Position
HW-C10
(NO)
HW-C01R
(NC-LB)
Operator Position
Mounting
Position
Operator Position
HW-C10
(NO)
ASW500-1
HW-C01
(NC)
HW-C10R
(NO-EM)
HW-C01R
(NC-LB)
Operator Position
Mounting
Position
Operator Position
Mounting
Position
Circuit Breakers
ASW300-3
ASW3K00-3
ASLW300-3
HW-C01
(NC)
Terminal Blocks
Contact
X
O
Contactors
HW-C10
(NO)
Left
Timers
HW-C10R
(NO-EM)
Operator Position
Contact
Mounting
Position
Operator Position
1
HW-C10
(NO)
ASW400
Mounting
Position
Signaling Lights
HW-C10
(NO)
Mounting
Position
639
Faceplates
NWAL
NWAQL
1.13" (29mm)
70mm
0.566"
(14.5mm)
1.76" (45mm)
0.975"
(25mm)
1.0"
Signaling Lights
Relays & Sockets
Timers
1.76" (45mm)
Part Number
NWAL-OB (black)
NWAL-OR (red)
NWAQL-OB (black)
NWAQL-OR (red)
NWAS-OB
NWAR-O
Nameplate
(engraved)
NWAL-j
NWAQL-j
NWAS-j
NWAR-27
1. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by .
2. Standard engravings are available at no charge.
3 NWAR-27 comes marked Emergency Stop as shown in drawing.
Code
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
Legend
OPEN
OUT
RAISE
RESET
REVERSE
RUN
SLOW
START
STOP
STOP
TEST
UP
I (Intl On)
O (Intl Off)
EMO
Pushbuttons/Selector Switches
Code
116
117
118
119
120
121
122
123
124
125
126
127
150
151
152
Legend
AUTO-MAN
CLOSE-OPEN
DOWN-UP
FAST-SLOW
FOR-REV
HAND-AUTO
HIGH-LOW
JOG-RUN
LEFT-RIGHT
LOWER-RAISE
MAN-AUTO
OFF-ON
ON-OFF
OPEN-CLOSE
RAISE-LOWER
Code
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
Legend
REV-FOR
RUN-JOG
RUN-SAFE
SAFE-RUN
SLOW-FAST
START-STOP
STOP-START
UP-DOWN
Selector Switches
Code
Legend
Code
216
217
218
219
220
221
222
223
AUTO-MAN-OFF
AUTO-OFF-MAN
CLOSE-OFF-OPEN
DOWN-OFF-SLOW
FAST-OFF-SLOW
FOR-OFF-REV
LEFT-OFF-RIGHT
LOWER-OFF-RAISE
OFF-MAN-AUTO
OFF-SLOW-FAST
OFF-1-2
OPEN-OFF-CLOSE
SLOW-OFF-FAST
SUMMER-OFF-WINTER
UP-OFF-DOWN
1-OFF-2
HAND-OFF-AUTO
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
Circuit Breakers
Terminal Blocks
EMERGENCY STOP
Nameplate
(blank)
Pushbuttons
Contactors
NWAS
1.13" (29mm)
(25.4mm)
22mm - TW Series
640
www.IDEC.com
22mm - TW Series
Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired.
To ensure engraving accuracy, fax it to your IDEC representative. or Distributor.
Telephone:_ _________________________________________
NWAL
Step 1.
7/64 Letters:
1/8 Letters:
Qty
8 9 10 11
7/64
11 characters max
(for 7/64 size letters)
1/8
9 characters max
(for 1/8 size letters)
Letter Size
Qty
4 5
8 9 10 11
20 characters max
(for 3/32 size letters)
1/8
14 characters max
(for 1/8 size letters)
Letter Size
8 9 10 11 12 13 14 15 16 17 18 19 20
Circuit Breakers
3/32
Letter Size
Specify Location.
Terminal Blocks
Contactors
1/8 Letters:
Step 3.
Qty
7/64 Letters:
Engraving Location B
Step 1.
4 5
Specify Quantity.
Letter Size
Engraving Location A
Timers
Specify Quantity.
Step 2.
Letter Size
Step 1.
NWAS
9 characters max
(for 1/8 size letters)
Step 2.
1/8
Specify Quantity.
Engraving
Location
11 characters max
(for 7/64 size letters)
Step 2.
NWAQL
7/64
Letter Size
Engraving
Location
Signaling Lights
3/32 Letters:
Location
1/8 Letters:
641
Signaling Lights
22mm - TW Series
Your Company:
Telephone:
Name:
Fax:
Address:
Email:
PO:
Please check one of the boxes below to indicate your choice of engraving options:
Relays & Sockets
# of Lines
Letter
Height
Max. Characters
Per Line
5/32
# of
Lines
Timers
Letter
Height
Max. Characters
Per Line
5/32
1
1/8
5/32
1/8
5/32
2
5
1/8
3/32
Contactors
1/8
1/8
1/8
3/32
Engraving
Area 1
Engraving
Area 2
5/32 Letters:
Line 2:
Line 3:
642
Line 1:
Line 4:
Circuit Breakers
# of
Lines
1. Above mentioned specifications hold true for standard size pushbuttons (round and square).
2. Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only.
3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights.
4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters.
Engraving
Round
Switch
Square
Switch
www.IDEC.com
Letter
Height
Max. Characters
Per Line
5/32
1/8
5/32
1/8
22mm - TW Series
Switches & Pilot Devices
Accessories
TW Series Accessories
Item
Appearance
Description/Usage
Part Number
Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to
determine panel thickness adjustment.
TW-KC1
Used in OR-14 locking wrench to tighten locking nuts inside square bezel
TW-KQ2
Metal Bezel
Plastic Bezel
AW-R8
AW-RF8
AW-G4
AW-RP1B
AW-FP1B
AW-Q1B
AW-QF1B
APW00LN
APW00L
OC-31
OC-32
OCW-11*
OGL-31
OB-31
For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of
12 kfg-cm maximum
Degree of protection: IP66
Replacement Keys
LW9Z-BM
Terminal Blocks
TW-SK
AKW2B-B
Circuit Breakers
Contactors
Anti-Rotation Ring
Replacement Black
Sleeve for Keyswitch
Timers
OR-55
Signaling Lights
OLW-C
643
Signaling Lights
22mm - TW Series
Item
Appearance
Description/Usage
Part Number
TW-FA1
Lock-out Adaptor
Used to provide lock-out protection for pushbuttons and knob selector switches:
Up to 40mm mushroom head size
(Padlock not included.)
Not applicable for e-stops.
HW9Z-KL1
TW to TWTD Adaptor
Used to mount TW series control unit (except square units) 7/8 (22mm) into a 1-13/64
(30mm) panel cut-out.
TWN-A1R8
Replacement Marking
Plates
ALW2B
APW2B
ALW3B
APQW1B
ALQW2B
Used with
644
Part Number
APS-PVL
HW-VL2
APW and UPQW transformer pilot lights, and illuminated pushbuttons and illuminated selectors
HW-VL3
HW-VL4
HW-VL5
HW-VL6
Circuit Breakers
Terminal Blocks
Contactors
Timers
Appearance
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Dimensions
Pushbuttons
37
30
30
47
M3.5 Terminal
Screws
37
37
30
47
Panel Thickness
1 to 6
37
40
25
25
Square Flush
Panel Thickness
1 to 6
37
40
M3.5 Terminal
Screws
45
13
40mm Push-Pull
Reset
(unlock)
13
22.5
45
37
Timers
M3.5 Terminal
Screws
Reset Angle 75
40
37
29
Panel Thickness
1 to 6
30
22.5
Panel Thickness
1 to 6
29
M3.5 Terminal
Screws
30
23
37
40mm Push-Lock-Turn-Reset
Reset Angle 75
Panel Thickness
1 to 6
30
22.5
25
30
Panel Thickness 1 to 6
37
37
22.5
M3.5 Terminal
Screw
Panel Thickness 1 to 6
13
29mm Push-Lock-Turn-Reset
M3.5 Terminal
Screws
40
Panel Thickness 1 to 6
29
48.5 (1-2 block)
24
40mm Mushroom
M3.5 Terminal
Screws
30
46
29mm Mushroom
30
19
30
Signaling Lights
30
Panel Thickness 1 to 6
37
24
M3.5 Terminal
Screws
Panel Thickness 1 to 6
37
29
24
Panel Thickness 1 to 6
M3.5 Terminal
Screws
M3.5 Terminal
Screws
29
Extended
M3.5 Terminal
Screws
29
Flush
13
25
30.5
30
Square Extended
37
Contactors
30
Panel Thickness
1 to 6
25
M3.5 Terminal
Screws
30
20
Selector Switches
48.5 (2 blocks)
13
25
30
68.5 (4 blocks)
13
25
30
48.5 (2 blocks)
68.5 (4 blocks)
37
29
24
37
37
25
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6
Terminal Blocks
29
M3.5 Teminal
Screws
Panel Thickness 1 to 6
29
M3.5 Terminal
Screws
Panel Thickness 1 to 6
24
M3.5 Terminal
Screws
13
19
41
30
Circuit Breakers
645
Illuminated Pushbuttons
Extended with Full Shroud
25
37
29
24
37
29
30
Panel Thickness
1 to 6
Reset Angle: 75
13
30
22.5
13
30
22.5
21mm
Panel Thickness
1 to 6
Reset Angle 75
40
37
13
Marking plate:
Mushroom
37
Panel Thickness
1 to 6
40mm Push-Turn-Reset
29
29mm Push-Turn-Reset
30
20
37
20
30
19
29
Signaling Lights
Panel Thickness
1 to 6
13
13
30
22.5
Marking plate: 13.9mm
Push-Pull
Panel Thickness
1 to 6
37
40
Square Extended
Panel Thickness
1 to 6
37
Panel Thickness
1 to 6
30
Extended
24
22mm - TW Series
13
25
30
30.5
Transformer (2 blocks)
X1
X1
Timers
X2
Panel Thickness
1 to 6
X1
X2
X2
Contactors
86.5
64.5
X1
Panel Thickness
1 to 6mm
X2
Panel Thickness
1 to 6
X1
X2
106.5
63.5
68.5
3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Half Size Transformer
M3.5
Terminal Screws
Panel Thickness
1 to 6
Panel Thickness
1 to 6
X1
X2
X2
X1
Terminal Blocks
X2
X1
X1
Circuit Breakers
X2
68.5
84.5
646
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Dimensions continued
Pilot Lights
Round Flush APW1 Transformer
28.5
30
28.5
66.5
25
37
30
37
37
Panel Thickness 1 to 6
28.5
66.5
22 mm
Timers
25
30
Marking plate:
30
25
M3.5 Terminal
Screw
Panel Thickness
1 to 6
13
13
16
37
29
23.6
37
30
25
13
Panel Thickness
1 to 6
M3.5 Terminal
Screw
29
23.6
13
30
17
Panel Thickness
1 to 6
16
13
66.5
29
24
28.5
30
28.5
Panel Thickness
1 to 6
37
13
17
28.5
29
24
Panel Thickness
1 to 6
30
17
Signaling Lights
28.5
13
66.5
17
37
24
37
13
30
28.5
Panel Thickness
1 to 6
29
24
Panel Thickness
1 to 6
29
30
Marking plate:
22 mm
A: 63.5 (2 blocks)
83.5 (4 blocks)
37
29
Panel Thickness 1 to 6
24
Contactors
13
25
30
Terminal Blocks
Circuit Breakers
647
22mm - TW Series
Dimensions continued
Panel Cut-Out
Diagram
Dimension
Part
Pushbuttons
1.17 (30mm)
Std. Octagonal
Pilot Light
C
Signaling Lights
1.95 (50mm);
1.76 (45mm)
minimum
0.137
(3.5mm)
Illuminated Pushbuttons
0.878
(22.3mm)
Selector Switches
D
1.17 (30mm)
*See note.
1.The 0.137 ( 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used.
2. *>1.404 (36mm) for 2- or 3-position.
>1.95 (50mm) for 4- or 5-position.
22.5
0.8
15
1.6t
18.5
Button
installed
21
AW-RP1B
Round Plastic Bezel
Panel Thickness
0.8 to 3.2
29
29
2.2
Key hole 8
29.5
30
Waterproof Rubber
Gasket 0.5t
HW-VL5
HW-VL4
HW-VL3
HW-VL2
APS-PVL
Circuit Breakers
Terminal Blocks
30
Contactors
70
30
13
93
6.5
R6
AW-QF1B
Square Full Shroud
24 (inside)
0
5 4.4)
4
:
(ID
648
3.5
3.5
AW-FP1B
Round Plastic w/Full Shroud
19.8
82.5
25
Button
installed
13
Timers
29
Extended
Flush
HW9Z-KL1
Lock-out Adaptor
31
.5
M22 P1.0
OB-31
Mounting Hole Rubber Plug
26
R42
32
Mounting Centers
50 min.
27.4
M22 P1.0
18.6
22
OCW-11
Pushbutton Rubber Boot
32
OLW-C
Metal Button Guard
31
OGL-31
Anti-Rotation Ring
10.2
Accessory Dimensions
www.IDEC.com
22mm - TW Series
Switches & Pilot Devices
Signaling Lights
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0.1 mm
1
1 mm
A
3
5
4
6
An adjustment for panel thicknesses shown below can be made quickly by using
the contact block remover tool.
Tool TW-KC1
1.6 mm
2
4
6
3
5
2.3 mm
3.5 mm
Timers
1 mm
2 mm
3.2 mm
Contactors
Terminal Blocks
Circuit Breakers
649
Signaling Lights
22mm - TW Series
Instructions continued
Pilot Lights and Pushbuttons
IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up.
Round
Marking
Unit
Lens
Insert marking
plate under lens
Marking
Plate
Press in
Square Bezels
Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally,
install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base.
Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be
printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on.
Insert
Insert marking
plate under lens
Marking Plate
Insert marking
plate under lens
Square Lens
Press in
Illuminated Pushbutton
Pilot Light
Square Lens
Timers
Square
Marking
Units
Marking Plate
Lens Retainer
To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the
indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16 screwdriver into one of the recesses.
Terminal Blocks
Contactors
Waterproof Lens
Circuit Breakers
Shape
Round
Engraving Area
Used With
Part Number
0.55 (14mm)
Illuminated pushbuttons
ALW2B
0.55 (14mm)
Pilot lights
APW2B
Mushroom
0.55 (14mm)
Illuminated mushroom
Square
q 0.83 (21mm)
APQW1B
Square
q 0.83 (21mm)
ALQW2B
650
ALW3B
www.IDEC.com
22mm - TW Series
Selector Switches
The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the
handle and then press handle into the operator, as shown below.
Recess
Press in
color insert
Selector Switch
(non-illuminated)
Signaling Lights
Press in
handle
Illuminated
Selector Switch
Remove color insert before pulling out the handle.
3-Postion, 45
4-Postion, 45
0
1
5-Postion, 30
2
Instructions, continued
Timers
Installation
TW Pilot Lights
Terminal X1 = Positive
Terminal X2 = Negative
Contactors
TW Illuminated Pushbuttons,
TW Selector Switches
(AC Transformer or Full Voltage)
Terminal Blocks
Terminal
X2
Circuit Breakers
Ter minal
X1
Diode
Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals.
651