Download as pdf or txt
Download as pdf or txt
You are on page 1of 498

Operator Handbook

Alcatel 1662SMC
STM4/16 Compact Multiservice Node

1662SMC Rel.2.4

3AL 98253 ADAA Ed.03

3AL 98253 ADAA Ed.03

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alcatel 1662SMC Rel2.4 Operator Handbook

Alcatel 1662SMC Rel2.4


Handbook Guide

03

09/01/2006

Creation

ED

DATE

CHANGE NOTE

Distribution: Internal

Chen Yu
APPROVED BY

PREPARED BY

3AL 98253 ADAA

1/15

External

ED

03

SC 1: HANDBOOK GUIDE

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

HANDBOOK STRUCTURE AND CONFIGURATION CHECK 3


1.1

General information 3

1.2

Handbook applicability3

1.3

Purpose of the handbook3

1.4

Handbook configuration check 44

PRODUCT-RELEASE HANDBOOKS 5

SAFETY NORMS AND LABELS 8


3.1

First aid for electric shock 8

3.2

Norms and labels 8

HANDBOOK DESCRIPTION 9

GENERAL ON ALCATEL CUSTOMER DOCUMENTATION 12


5.1

Products, product-releases, versions and Customer Documentation12

5.2

Handbook supply to Customers12

5.3

Aims of standard Customer Documentation12

5.4

Handbook Updating 12

5.4.1

Changes introduced in the same product-release (same handbook P/N) 13

5.4.2

Supplying updated handbooks to Customers13

5.4.3

Changes due to a new product-release13

5.5

ED

Customer documentation supply on CD-ROM14

5.5.1

Contents, creation and production of a CD-ROM14

5.5.2

Use of the CD-ROM14

5.5.3

CD-ROM identification 15

5.5.4

CD-ROM updating 15

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

2/15

1
1.1

HANDBOOK STRUCTURE AND CONFIGURATION CHECK


General information
WARNING

ALCATEL makes no warranty of any kind with regards to this manual, and specifically disclaims the implied
warranties of merchantability and fitness for a particular purpose. ALCATEL will not be liable for errors
contained herein or for damages, whether direct, indirect, consequential, incidental, or special, in connection
with the furnishing, performance, or use of this material.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

NOTICE
The product specification and/or performance levels contained in this document are for information purposes
only and are subject to change without notice. They do not represent any obligation on the part of ALCATEL.
COPYRIGHT NOTIFICATION
The technical information of this manual is the property of ALCATEL and must not be copied, reproduced or
disclosed to a third party without written consent.

1.2

Handbook applicability

This handbook applies to the following product-releases:

PRODUCT

ANV P/N

FACTORY P/N

1662SMC

3AL 98001 AAAA

--

PRODUCT

RELEASE

VERSION(N.B.)

ANV P/N

FACTORY P/N

1662SMC

2.4

3AL 98002 AHAA

--

For further information on the Alcatel software product and its physical distribution support refer to the
Introduction section.
N.B. NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS
Handbooks relevant to software applications (typically the Operators Handbooks) are not modified
unless the new software version distributed to Customers implies man-machine interface changes or
in case of slight modifications not affecting the understanding of the explained procedures.
Moreover, should the screen prints included in the handbook contain the product-releases version
marking, they are not replaced in the handbooks related to a subsequent version, if the screen
contents are unchanged.

1.3

Purpose of the handbook

This handbook describes the operations concerning commissioning, operation and maintenance that the
operators must carry out as indicated by the specific software application(s) referred to in this handbook
This handbook must be used together with the associated Technical Handbook (see Table 1.) and the
1320CT associated documentation (see Table 5.) does not replicate information contained into it.
In particular, all cautions relevant to safety, rules for EMC and ESD, as well as warnings regarding
operations that may cause damages to the equipment, are not duplicated here, but must be retrieved from
the Technical Handbook.

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

3/15

When using this handbook it is assumed that the Operators know:

1.4

The structure (hardware composition) and all the possible operating modes of the equipment
(product-release) this handbook refers to.

How to use a PC and the Windows ambient applications

Handbook configuration check

This handbook is a collection of documents (each contained in a specific section) that can have
editions different from one another.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

The Edition of the whole handbook is that of section 1 (HANDBOOK GUIDE).


The edition of the enclosed documents indicated in the following table is that of the corresponding original
internal document.

HANDBOOK EDITION

01

REGISTER AND SECTION TITLE

ED

03

02

03

04

05

SECTION EDITION

HANDBOOK GUIDE

INTRODUCTION MANUAL

NE MANAGEMENT MANUAL

MAINTENANCE MANUAL

SIBDL MANUAL

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

4/15

PRODUCT-RELEASE HANDBOOKS

The list of handbooks given here below is valid on the issue date of this Handbook and can be
changed without any obligation for ALCATEL to update it in this Handbook.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Some of the handbooks listed here below may not be available on the issue date of this
Handbook.
The standard Customer Documentation in the English language for the equipment whose product-releaseversion is stated in para.1.2 consists of the following handbooks:
Table 1. Handbooks related to the specific product hardware
REF

HANDBOOK

ANV Part No.

FACTORY

THIS HDBK

Part No.

[1]

1662SMC Rel.2.4 Technical


Handbook

3AL 98253 AAAA

Provide information regarding Equipment description, Maintenance, Hardware


setting documentation

[2]

1662SMC Rel.2.4 Installation


Handbook

3AL 98253 ABAA

Provide information regarding Equipment Installation


1662SMC Rel.2.4 Turnup &
Commissionig Handbook
[3]

3AL 98253 ACAA

Provide information regarding Equipment Turn-On, Test and Operation

Table 2. Handbooks related to the specific product SW management and local product control
REF

HANDBOOK

1662SMC Rel.2.4

ANV Part No.

3AL 98253 ADAA

FACTORY

THIS HDBK

Part No.

Or note

--

CT Operators Handbook
[4]

ED

Provides 1662SMC SDH Craft Terminal screens and operational procedures

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

5/15

Table 3. Handbooks related to ATM specific product SW

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

REF

HANDBOOK

ANV Part No.

FACTORY

THIS HDBK

Part No.

Or note

[5]

ATM Rel.1.0 Operators Handbook

3AL 80730 AAAA

957.140.552 J

[6]

ATM Rel.1.2 Operators Handbook

3AL 80814 AAAA

957.140.652 W

Provides ATM SMART Terminal screens and operational procedures

Table 4. Handbooks related to IP specific product SW


REF

[7]

HANDBOOK

IP Rel.1.0

ANV Part No.

3AL 81062 AAAA

FACTORY

THIS HDBK

Part No.

Or note

957.140.722 L

Operators Handbook
Provides ATM SMART Terminal screens and operational procedures

Table 5. Handbooks common to Alcatel Network Elements using 1320CT platform


REF

HANDBOOK

ANV Part No.

FACTORY

THIS HDBK

Part No.
1320CT
[8]

3AL 79186 AAAA

957.130.542 E

Basic Operators Handbook


Provides general information and operational procedures common to all 1320CT
(Craft terminal) of Alcatel InfoModel Network Elements.
1330AS Rel.5.1 Operators
Handbook

[9]

ED

957.130.442 A

Provides detailed information and operational procedures regarding the alarm


Surveillance software embedded in the 1320CT software package. Information
about Historical Alarms and Network Element Symbols Management (Physical
Network Management) are not valid for Craft Terminal. They are only used by
Network Management.
ELM Rel.5.0 Operators Handbook

[10]

3AL 71079 AAAA

3AL 71081 AAAA

957.130.462 E

Provide detailed information and operational procedures regarding the Event


Log Management software embedded in the 1320CT software package.

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

6/15

Table 6. Documentation on CD-ROM


REF

[11]

CD-ROM TITLE

1662SMC Rel.2.4 CD-ROM-DOC


EN

ANV Part No.

FACTORY Part No.

3AL 98254AAAA

Contains, in electronic format, the following handbooks: REF. [1] to [4] Envisaged after the
release of all handbooks

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1320CT BASIC CD-ROM-DOC EN


[12]

3AL 79549 AAAA

417.100.031

Contains, in electronic format, the following handbooks: REF. [8] to [10]

ATM Rel.1.1 CD-ROM DOC EN

3AL80739 AAAA

417.100.060

[13]
Contains, in electronic format, the following handbooks: REF. [5] Envisaged after the release of
all handbooks
[14]

ATM 1.2 CD-ROM-DOC EN

3AL 80815 AAAA

417.100.068

Contains, in electronic format, the following handbook: REF. [6]


[15]

IP 1.0 CD-ROM-DOC EN

3AL 81063 AAAA

417.100.084

Contains, in electronic format, the following handbook: REF. [7]

Table 7. Optional handbooks common to 16xxSM


REF

HANDBOOK

ANV Part No.

FACTORY

THIS HDBK

Part No.
S9-16xxSM
[16]

3AL 78901 AAAA

955.100.692 N

System Installation Handbook


Provides general installation rules necessary to install the Optinex family
equipment in the S9 Rack.

[17]

Optinex RACK-16xxSM System


Installation Handbook

3AL 38207 AAAA

955.110.202 L

Provides general installation rules necessary to install the Optinex family


equipment in the Optinex Rack.

N.B.

ED

Handbooks REF. [16] and [17] are available only on paper support

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

7/15

SAFETY NORMS AND LABELS

3.1

First aid for electric shock

Do not touch the patient with bare hands until the circuit has been opened.
Open the circuit by switching off the line switches. If that is not possible, protect yourself with dry material
and free the patient from the conductor.
ARTIFICIAL RESPIRATION

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

It is important to start mouth-to-mouth resuscitation at once and seek doctor help immediately.
TREATMENT OF BURNS
This treatment should be used after the patient has regained consciousness. It can also be employed while
the artificial respiration is being applied (in this case there should be at least two persons present).
WARNING:

Do not attempt to remove his clothing from the burnt parts;

Apply dry gauze on the burns;

Do not apply ointments or other oily substances.

3.2

Norms and labels

Refer to the Technical Handbook associated to ALCATELs designed and manufactured equipment to
obtain the following information:
-

COMPLIANCE WITH EUROPEAN NORMS.

SAFETY RULES

General rules

Harmful optical signals

Risk of explosion

Moving mechanical parts

Heat-radiating Mechanical Parts

ELECTROMAGNETIC COMPATIBILITY

ELECTROSTATIC DISCHARGERS (ESD)

EQUIPMENT LABELS

Identical or similar information on Personal Computer, Work-Station etc., other than ALCATELs, loaded
with software applicative described in this Handbook, is supplied in the Constructors technical
documentation.

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

8/15

HANDBOOK DESCRIPTION

This handbook is composed of the following Manuals:


SECTION 1: HANDBOOK GUIDE (This document)
The Handbook Guide gives general information on the application and use of the Handbook. The

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Handbook Guide includes the following chapters:


-

Chapter 1:Handbook structure and configuration check. This chapter gives information on the whole
handbook application, composition and evolution.

Chapter 2: Product-release handbooks. This chapter lists the handbooks the Operator should have
in order to carry out the tasks allowed by the specific product-release this handbook refers to.

Chapter 3: Safety norms and labels

Chapter 4: Handbook description

Chapter 5: General on Alcatel Customer Documentation

SECTION 2: INTRODUCTION Manual


The Introduction Manual describes the main features of the graphical interface and provides a general
overview of the system architecture and the different functionalities provided by the Craft Terminal. The
Introduction Manual includes the following chapters:
-

Chapter 1: Introduction. This chapter gives the structure of this manual.

Chapter 2: General description of the Craft Terminal. The Craft Terminal is introduced and the
software product listed. The Craft Terminal main functionality in the NE management (EML-USM)
are listed and briefly described.

Chapter 3: Acronyms and abbreviations. The acronyms used in all the operator manuals are listed.

Chapter 4: Glossary of terms. Definitions concerning the acronyms.

SECTION 3: NETWORK ELEMENT MANAGEMENT Manual


The aim of this document is to describe the Craft Terminal view, inserting operative information.
The Network Element Manual includes the following chapters:

ED

Chapter 1: Introduction. This chapter gives the structure of this manual.

Chapter 2: General introduction on views and menus. The view organization is presented and the
menus available listed and briefly described.

Chapter 3: NE management supervision. This chapter is dedicated to the NE states and NE access.

Chapter 4: NE management general configuration. In this chapter general configuration referred to


the equipment management are described (CT access, NE Time, Alarm Configuration etc).

Chapter 5: Security Management. In this chapter configuration referred to the Security management
are described (ACD level and Manager list).

Chapter 6: External input and output points management. This chapter describes how to display and
set the input/output environmental alarm (housekeeping alarm).

Chapter 7: Diagnosis management. In this chapter are specified: access to the Alarm Surveillance to
show the alarm condition, abnormal condition list (as result of operators command), access to the
Event and Alarm Log file and Internal Link Monitor.

Chapter 8: Communication and Routing management. In this chapter are presented the
communication and routing parameters, concerning the OSI and IP communication protocols for the
03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

9/15

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

local NE, the OS and each other related NE in order to provide a global communication capabilities
inside the network
-

Chapter 9: Equipment management. This chapter deals mainly with the setting and changing of the
boards present on the Equipment and undertaking board protection operations.

Chapter 10: Board view. This chapter permits to show the physical port available in a specific board
(alarm synthesis and port symbol), to access the port and to change the physical interface.

Chapter 11: Port view. This chapter permits to set and show the transmission resources referred to
the Port.

Chapter 12: Equipment protection management. This chapter permits to manage the EPS protection,
setting the relevant configuration.

Chapter 13: Multiplex Section protection management. This chapter permits to manage the MSP
protection.

Chapter 14: Transmission view. This chapter permits to show and set the Termination Point of the
equipment, thus having an overview of the complete signal flow of the various port.

Chapter 15: Cross connection management. This chapter permits to manage the connection of the
paths.

Chapter 16: Overhead management. This chapter permits to manage the Overhead, setting the
relevant configuration.

Chapter 17: Performance Monitoring management. This chapter permits to set and show
Performance Monitoring parameters and data.

Chapter 18: Synchronization management. This chapter permits to set and show Synchronization
parameters and status.

Chapter 19: MSSPRing Management. This chapter permits to set the MSSPRing protection of the
NE

Chapter 20: ISA/IP/ETH Configuration. This chapter describes the operations necessary for the ATM
boards creation and the ATM/IP/ETH TTPs creation.

Chapter 21: Software management. This chapter permits to update the NE by means download
procedure and to manage NE software.

SECTION 4: NETWORK ELEMENT MAINTENANCE Manual


This document aims at introducing the Maintenance procedure, inserting information useful to identify alarms
and troubleshoot the NE. The Maintenance Manual includes the following chapters:
-

Chapter 1: Introduction. This chapter gives the structure of this manual.

Chapter 2: Maintenance introduction. List the maintenance steps.

Chapter 3: Maintenance of the Personal Computer. The Personal Computer manual is referred.

Chapter 4: Problems with Craft terminal. Shut Cdown and restart of the PC is indicated.

Chapter 5: Troubleshooting (Corrective Maintenance). Detection location and correction of failure are
presented.

Chapter 6: Unit replacement with spare. The replacement procedure is detailed.

Chapter 7: Upgrading with New Hardware. The Hardware upgrading procedure is detailed.

SECTION 5: SIBDL Manual


This document describes the download procedure with SIBDL. The SIBDL Manual includes the following
chapters:

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

10/15

Chapter 1: Introduction

Chapter 2: Download with SIBDL configuration

Chapter 3: Configuration for SIBDL

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

11/15

GENERAL ON ALCATEL CUSTOMER DOCUMENTATION

5.1

Products, product-releases, versions and Customer Documentation

A product is defined by the network hierarchical level where it can be inserted and by the whole of
performance and services for which it is meant.
A product evolves through successive product-releases which are the real products marketed for their
delivery at a certain product-release availability date.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

So, a product-release defines a set of hardware components and a software package which, as a whole,
identify the possible network applications and the equipment performance which the specific
product-release has been designed, engineered and marketed for.
In some cases a product-release has further development steps, named versions, that are born to
improve or add some performance (mainly software) with respect to the previous version, or for bug fixing
purposes.
A product-release has its own standard Customer Documentation, composed by one or more handbooks.
A new version of a product-release may or may not produce a change in the status of the Customer
Documentation set, as described in para.5.4.

5.2

Handbook supply to Customers

Handbooks are not automatically delivered together with the equipment they refer to.
The number of handbooks per type to be supplied must be decided at contract level.

5.3

Aims of standard Customer Documentation

Standard Customer Documentation, referred to hereafter, must be always meant as plant-independent.


Plant-dependent documentation, if envisaged by the contract, is subjected to commercial criteria as far as
contents, formats and supply conditions are concerned (plant-dependent documentation is not described
here).
Standard hardware and software documentation is meant to give the Customer personnel the possibility and
the information necessary for installing, commissioning, operating and maintaining the equipment according
to Alcatel-Telecom Laboratory design choices.
In particular the contents of the handbooks associated to the software applications focus on the explanation
of the man-machine interface and of the operating procedures allowed by it.
Consequently, no supply to the Customers of design documentation (like software source programs,
programming tools, etc.) is envisaged.

5.4

Handbook Updating

The handbooks associated to the product-release are listed in para.2.


Each handbook is identified by:

ED

The name of the product-release (and version when the handbook is applicable to the versions
starting from it, but not to the previous ones),

The handbook name,

The handbook P/N,

The handbook edition (usually first edition=01),


03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

12/15

5.4.1

The handbook issue date. The date on the handbook does not refer to the date of print but to the
date on which the handbook source file has been completed and released for the production.
Changes introduced in the same product-release (same handbook P/N)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The edition and date of issue might change on future handbook versions for the following reasons:
-

Only the date changes (pointed out in the Table of Contents) when modifications are made to the
editorial system not changing the technical contents of the handbook.

The edition, hence the date, is changed because modifications made concern technical contents. In
this case:

The table in para.1.4 on page 5 indicates the section(s) edition change;

In each section, the main changes with respect to the previous edition are listed;

In affected chapters of each section, revision bars on the left of the page indicate
modifications in text and drawings (this is done after the first officially released and validated
version).

Changes concerning the technical contents of the handbook cause the edition number increase (e.g. from
Ed.01 to Ed.02). Slight changes (e.g. for corrections) maintain the same edition but with the addition of a
version character (e.g. from Ed.02 to Ed.02A).
NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS
Handbooks relevant to software applications (typically the Operators Handbooks) are not modified
unless the new software version distributed to Customers implies man-machine interface hanges
or in case of slight modifications not affecting the understanding of the explained procedures.
Moreover, should the screen prints included in the handbook contain the product-releases
version marking, they are not replaced in the handbooks related to a subsequent version, if the
screen contents are unchanged.
5.4.2

Supplying updated handbooks to Customers

Supplying updated handbooks to Customers who have already received previous issues is submitted to
commercial criteria.
By updated handbook delivery it is meant the supply of a complete copy of the handbook new issue
(supplying errata-corrige sheets is not envisaged).
5.4.3

Changes due to a new product-release

A new product-release change the handbook P/N and the edition start from 01. In this case the modified
parts of the handbook are not listed.

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

13/15

5.5

Customer documentation supply on CD-ROM

In the following CD-ROM means Customer Documentation on CD-ROM


5.5.1

Contents, creation and production of a CD-ROM

In most cases, a CD-ROM contains the documentation of one product-release(-version) and for a certain
language.
In some other cases, the same CD-ROM can contain the documentation of different Product-release (version) s for a certain language.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

As a general rule:
CD-ROMs for Network Management products do not contain:
The Installation Guides
The documentation of system optional features that Customers could not buy from Alcatel together with the
main applicative SW.
CD-ROMs for Network Elements products do not contain the documentation of system optional features (e.g.
System Installation Handbooks related to racks that Customers could not buy from Alcatel together with the
main equipment).
A CD-ROM is obtained collecting various handbooks and processing them by
Interleaf-World-View-Press after the manual addition of some hyperlinks that make the navigation through
the various handbooks easier. No additional information is added to each handbook; so that the
documentation present in the CD-ROMs is exactly the same the Customer would receive on paper.
The files processed in this way are then transferred on a PC where the viewer (Interleaf-World-View) is
added and a master CD-ROM is recorded.
Suitable checks are made in order to have a virus-free product.
After a complete functional check, the CD-ROM image is electronically transferred to the archive of the
Production Department, so that the CD-ROM can be produced and delivered to Customers.
5.5.2

Use of the CD-ROM

The CD-ROM can be used both in PC and Unix WS environments.


The minimum configuration for World View (Rel.2.2.2) utilization on a PC is:
-

Operative System: Windows 95 or Windows NT 4

Processor: Pentium

RAM: 32 Mbyte

Disk space: 20Mbyte

The set-up procedure is present in the booklet included in the CD-ROM box.
After the set-up procedure, which installs the viewer in the PC or Unix WS environment, the Customer is
allowed to read the handbooks on the PC/WS screen, using the navigation and zooming tools included in the
viewer, and to print selected parts of the documentation through a local printer.
N.B. Copyright notification
WorldView:

Copyright 1981-1996
INTERLEAF Inc.

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

14/15

All rights reserved.


The use of WorldView is permitted only in association with the files contained
in the CD-ROMs officially supplied by Alcatel.
Alcatel documents: All rights reserved.
Passing and copying of documents and files contained in the CD-ROMs
officially supplied by Alcatel, use and communication of its contents are not

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

permitted without written authorization from Alcatel.

5.5.3

CD-ROM identification

Each CD-ROM is identified:


1) By the following external identifiers, that are printed both on the booklet and the CD-ROM upper
surface:
-

The name of the product-release(s) (and version when the CD-ROM is applicable to the
versions starting from it, but not to the previous ones),

A writing indicating the language(s),

The CD-ROM P/N (Factory P/N 417.xxx.xxx x and ANV P/N),

The CD-ROM edition (usually first edition=01)

2) And, internally, by the list of the source handbooks and documents (P/Ns and editions) by whose
collection and processing the CD-ROM itself has been created.
5.5.4

CD-ROM updating

The list of source handbook/document P/Ns-editions indicated in previous para.5.5.3 point 2), in association
with the CD-ROMs own P/N-edition, is also loaded in the Alcatel-Information-System as a structured list.
Whenever a new edition of any of such handbooks/documents is released in the Alcatel archive system, the
Alcatel-Information-System automatically rises a warning toward the Customer Documentation department,
indicating the list of CD-ROMs that must be updated to include the new editions of these
handbooks/documents.
This causes the planning and creation of a new edition of the CD-ROM.
Updating of CD-ROMs always follows, with a certain delay, the updating of the single handbooks composing
the collection.

END OF DOCUMENT

ED

03

SC 1: HANDBOOK GUIDE
3AL 98253 ADAA

15/15

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alcatel 1662SMC Rel2.4 Operator Handbook

Alcatel 1662SMC Rel2.4


Introduction

03

09/01/2006

Creation

ED

DATE

CHANGE NOTE

Distribution: Internal

Chen Yu
APPROVED BY

PREPARED BY

External

ED

03

SC.2:Introduction
3AL 98253 ADAA

1/15

LIST OF FIGURES AND TABLES ....................................................................................................................3


1

INTRODUCTION .......................................................................................................................................4
1.1

Scope4

1.1.1

Document scope...........................................................................................................................4

1.1.2

Target audience............................................................................................................................4

1.2

Reading rules 4

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.2.1
2

Menu options ................................................................................................................................4

GENERAL DESCRIPTION OF THE CRAFT TERMINAL ........................................................................5


2.1

Introduction 5

2.2

Alcatel software product and licence delivered to the customer 5

2.2.1

Software product and licences description ...................................................................................5

2.2.2

Software products and licences list and part numbers.................................................................6

2.3

Craft Terminal main functionalities in the NE management6

2.3.1

Network Element management supervision .................................................................................6

2.3.2

Network Element general configuration........................................................................................7

2.3.3

Security Management...................................................................................................................7

2.3.4

External input and output point management...............................................................................7

2.3.5

Diagnosis management ................................................................................................................7

2.3.6

Communication and routing management....................................................................................7

2.3.7

Equipment and board management .............................................................................................8

2.3.8

Port management .........................................................................................................................8

2.3.9

Protection management................................................................................................................8

2.3.10

Transmission management ......................................................................................................8

2.3.11

Cross Connection management...............................................................................................9

2.3.12

Performance monitoring management .....................................................................................9

2.3.13

Synchronization management..................................................................................................9

2.3.14

ATM/IP/ETH Configuration.......................................................................................................9

2.3.15

Software management .............................................................................................................9

ACRONYMS AND ABBREVIATIONS ....................................................................................................10

GLOSSARY OF TERMS .........................................................................................................................12

ED

03

SC.2:Introduction
3AL 98253 ADAA

2/15

LIST OF FIGURES AND TABLES

TABLES
Table 1. Software products part numbers ..........................................................................................................6

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Table 2. Software licence part numbers.............................................................................................................6

ED

03

SC.2:Introduction
3AL 98253 ADAA

3/15

INTRODUCTION

1.1

Scope

1.1.1

Document scope

The Introduction Manual presents the Craft Terminal main functions and provides a general overview of the
different functionalities provided by the ELMUSM of the Craft Terminal for Info Model NE.
1.1.2

Target audience

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Introduction Manual is intended for all users.


The documents that should be read before starting this document are:

1320CT Basic Operators Handbook

1.2

Reading rules

1.2.1

Menu options

All the manuals describe menus, but not necessarily all the options of these menus. When a menu option is
not detailed in a manual, the information is surely given in another manual.

ED

03

SC.2:Introduction
3AL 98253 ADAA

4/15

GENERAL DESCRIPTION OF THE CRAFT TERMINAL

2.1

Introduction

The Craft Terminal is a project in charge of the local management of single network elements, providing
ITU compliant Information Model Interface to the Network Element.
Multiple NE management up to 32 Network elements is possible obtaining a remote Craft Terminal
application.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The general information of the Craft Terminal are presented in the Basic Craft Terminal Operators
Handbook, which the operator has to read before this Handbook.
In the Basic Craft Terminal Operators Handbook are described all the general description of use, navigation,
rules, etc, common to all the NE using the same Craft Terminal.
Further, the same handbook contains the detailed description of common operations as Installation and
common screens as Network Element Synthesis view.
The Network Element Synthesis view is the first view presented to the operator entering the application.
Starting from this view it is possible login the NE and than enter the EMLUSM views.
This Operators Handbook deals with the EMLUSM views of the Craft Terminal, which directly
permit to manage the Network Element.
The management main functions of the EMLUSM are inserted at para. 2.3.
A detailed description of the EMLUSM screens is given in Section Ne Management of this handbook.
From the Craft Terminal is possible to run another Specific Software application. This application is in charge
of the ATM and IP management inside the NE such as ATM/IP crossconnection, Backup and Restore
configuration files etc.
Details information about Specific Application are described in the relevant Operators Handbook (see
Section 1 HANDBOOK GUIDE for the code).
The list and part numbers of the SDH software products distributed by Alcatel is inserted in para.2.2.
The Craft Terminal characteristic (computer configuration) are listed in the Basic Craft Terminal Operators
Handbook.

2.2
2.2.1

Alcatel software product and licence delivered to the customer


Software product and licences description

The software products are distributed by Alcatel in a CDROM.


In this CDROM are contained:
Software packages for NE management by means of the craft terminal
Software package of the NE, to be installed in the NE or update the NE (by means of download function)
The software package used for management permits the dialogue between craft terminal and NE, to realize
all the functions of the NES and EMLUSM.
The software package used for updating the NE must be installed on the PC and then downloaded on the
NE, thus following product evolution.
Alcatel typically offers several software licenses on the software product (only one for this equipment)
They are referred both to the Network Element software features and to the Craft Terminal software features.

ED

03

SC.2:Introduction
3AL 98253 ADAA

5/15

2.2.2

Software products and licences list and part numbers

Every Software Product is identified by a denomination and a part number, listed on the following table.
Table 1. Software products part numbers
Name

ANV Part Number

FACTORY Part Number

DCP 1662SMC R 2.4 CDROM

3AL 98183 AAAA

415.100.666 N

N.B.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Every Software licence is identified by a denomination and a part number, listed on the following table.
Table 2. Software licence part numbers
Name

ANV Part Number

FACTORY Part Number

N.B.

SWLA 1662SMC Rel. 2.4

3AL 98180 AAAA

700.200.301 X

3AL 98180 ABAA

700.200.302 Y

3AL 98180 ACAA

700.200.303 Z

3AL98185 AAAA

700.200.304 S

3AL 98185 ABAA

700.200.305 T

LICENCE FEE
SWLB 1662SMC Rel. 2.4
LICENCE FEE
SWLC 1662SMC Rel. 2.4
LICENCE FEE
SWLLCT 1662SMC Rel. 2.4
LICENCE FEE
SWLRCT 1662SMC Rel. 2.4
LICENCE FEE
N.B. 1
License alternative for Network Element software features:
SWLA: Full functionality set
SWLB: Improved functionality set
SWLC: Basic functionality set
N.B. 2
License alternative for Craft Terminal software features:
SWLLCT: Local Craft Terminal functionality
SWLRCT: Remote Craft Terminal functionality

2.3

Craft Terminal main functionalities in the NE management

In this chapter, are described the main functionalities of the Craft Terminal, referred to the Network Element
management views, obtained by means EMLUSM. The functionalities constitute the heading of each of the
paragraphs below.
2.3.1

Network Element management supervision

Deals with the NE state and access.


ED

03

SC.2:Introduction
3AL 98253 ADAA

6/15

2.3.2

Network Element general configuration

Deals with the general configuration of the equipment.


Craft Terminal access state (allow or inhibit)
NE Time management
Alarms Configuration

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alarm Severity Assignment Profile management,


Allow/Inhibit alarm notification,
Alarm re-synchronization.
Restart NE
2.3.3

Security Management

Deals with the security configuration of the equipment.


Set Manager list
Set ACD level
2.3.4

External input and output point management

Deals with housekeeping signals input from the external (station alarms) or forwarded (output) towards the
external.
Display External points
Configure External points
2.3.5

Diagnosis management

For real time alarm reporting and subsequent fault localization and correction.
Alarm Surveillance
The alarms concerning a particular managed entity will be represented in a synthetic way in all the views
concerning the entity.
Alarms information are detailed in the Alarms Surveillance Manual
Abnormal Condition list (as result of operators commands)
Event log Manager
Permits to have access to the Event Log file.
Remote Inventory (upload and view remote inventory)
Internal Link Monitor
2.3.6

Communication and routing management

This deals with the configuration parameters concerning the communication protocols for the local NE, the
OS and each other related NE. Different types of protection can be managed:
Local NE and OS addresses
NTP configurations
LAPD, Ethernet, MESA, RAP configurations
ED

03

SC.2:Introduction
3AL 98253 ADAA

7/15

IP Configuration
Tunneling Configuration
2.3.7

Equipment and board management

Deals with the presentation of the equipment and the hierarchical tree structure, permitting to define the
types of boards present. The Board view permits to access the Port view.
Set / modify / remove boards
Software information of the selected board.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Remote Inventory
2.3.8

Port management

This permits to set and show the transmission resources (TP) referred only to the port (SDH, PDH, HOA
ATM and IP).
It is used to check the detailed alarm of each TP and to configure them (many options are the same of the
Transmission view).
For each port a specific menu is available where various configuration of the specific port can be set, for
example:
Automatic Laser Shutdown
MSP protection
Loopback management and configuration
Single fiber configuration
TP Frame Mode Configuration
Retiming
Ethernet Port Configuration
Port view is also the entry point of other management functions:
Performance Monitoring management
Cross Connection management
For each port are presented:
The various ITUT functional blocks (i.e. PPI, RST, VC4).
Details of alarm and state condition
TP role, connection, etc. information
2.3.9

Protection management

This deals with the protection mechanism that is possible to configure in the NE. Different types of
protection can be managed:
Equipment protection switching
Multiple Section Protection
2.3.10 Transmission management
This permits to cover the management of the transmission resources, opening the views of all the specific
ports of the NE (SDH and PDH).
ED

03

SC.2:Introduction
3AL 98253 ADAA

8/15

It supplies an overview of the complete signal flow.


For all the ports are presented:
The various ITUT functional blocks (i.e. PPI, RST, VC4).
Synthesis of alarm and state condition
TP role, connection, etc. information
For each port a specific menu is available similar to the Port view where various configuration of the specific
port can be set.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Also Transmission view is than the entry point of other management functions .
2.3.11 Cross Connection management
This deals with the connection of all the Termination Point (TP), which are the starting and terminating points
of a transmission segment. In this way the multiplex structures are created, managing the traffic flow. Similar
operation are made on the Overhead cross connections.
Create / modify cross connections
Activate / deactivate / switch cross connections
2.3.12 Performance monitoring management
This function deals with the set up, collect, log and display performance data associated with the managed
NE according ITUT G.826.It consists of a set of functions that evaluate and report on the behavior of the
NEs and their effectiveness relating to the communications taking place on the Network.
Set up the Performance Monitoring thresholds
Collect and display Performance Monitoring data
Performance monitoring history
2.3.13 Synchronization management
Deals with the management of the timing.
Timing source, SSU, T0, T4, T5 and T6 configuration
Protection commands
2.3.14 ATM/IP/ETH Configuration
Describes the operations necessary for the ATM/IP/ETH boards and the ATM/IP/ETH TPs creation.
2.3.15 Software management
Deals with the manipulation of the software package within NE.
Software download refers to the NE software, permitting to charge the software in the relevant NE to
upgrade the NE software, thus following product evolution, or as a consequence of substitution with a spare.
Backup and restore on the MIB of the NE.

ED

03

SC.2:Introduction
3AL 98253 ADAA

9/15

ACRONYMS AND ABBREVIATIONS

AIS: Alarm Indication Signal


APS: Automatic Protection Switching
ASAP: Alarm Severity Assignment Profile
ATM: Asynchronous Transfer Module
CDROM: Compact Disc Read Only Memory

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

CCITT: Telegraph and Telephone International Consultative Committee


CT: Craft Terminal
DCN: Data Communications Network
ECC: Embedded Communication Channels
EML: Element Management Layer
EPS: Equipment Protection Switching
FAD: Functional Access Domain
Gbit/s: Gigabits per second
GNE: Gateway Network Element
HMI: Human Machine Interface
IEEE: Institute of Electrical and Electronics Engineers
IM: Information Manager
Kbit/s: Kilobits per second
LAN: Local Area Network
LVC: Lower Order Virtual Container
MAC: Media Access Control
Mbit/s: Megabits per seconds
MIB: Management Information Base
MS: Multiplex Section
MSP: Multiplex Section Protection
NAD: Network Access Domain
NAP: Network Access Point
NE: Network Element
NML: Network Management Layer
NTP: Network Time Protocol
OS: Operation System
PI: Physical Interface
SD: Signal Degrade
SF: Signal Failure

ED

03

SC.2:Introduction
3AL 98253 ADAA

10/15

TMN: Telecommunications Management Network


TN: Telecommunications Network
TP: Termination Point
USM: User Service Manager

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

XC: CrossConnection

ED

03

SC.2:Introduction
3AL 98253 ADAA

11/15

GLOSSARY OF TERMS

Acknowledgment:
When an alarm is taken into account by the application, the operator has to acknowledge it to point out that
he has seen it and that he will react in the right way. During alarm configuration it is possible to set a
maximum delay for alarm acknowledgement. The operator can decide whether or not the alarm clear has to
be acknowledged.
Administrator:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

A user who has access rights to all the Management Domains of the Craft Terminal product. He has access
to the whole network and to all the management functionalities.
Alarm:
An alerting indication to a condition that may have an immediate or potentially negative impact on the state
of an equipment or the CT. An alarm is characterized by an alarm begin and an alarm end.
Alarm Severity Assignment Profile:
Function allowing the assignment of severities to the alarms depending on their probable causes.
Alarm Status:
Identifies the type and severity of an occurring alarm.
Board:
A board is part of an NE. They are electronic cards that fit into slots in the NE.
Compact Disk Read Only Memory:
Data saving support from which the information can only be read. Is useful for stocking data due to its
available memory space.
Craft Terminal:
Workstation or Personal computer (PC) from which local address to an NE is possible. It can be used to
configure or perform monitoring tasks on the NE.
Crossconnection
CrossConnections provide the network with the Routing Capabilities, this is the possibility of routing one
signal to a particular destination.
Digital Communication network:
Communication Network in which the transmission of data is done in a digitized format.
Embedded Communication Channel:
Communication channel used in conjunction with packet commuting networks (X25) to manage distant SDH
networks. These communication channels are related to the QECC* protocols.
Element Management Layer:
This application is responsible for the configuration and management of Network Elements.
Equipment Protection Switching:
Used to provide protection for cards within an equipment to protect traffic in the event of card failure.
Filter:
They are related to the alarms or events generated on an NE or internally within the OS itself. They can be
configured by an operator to reject specified types of notifications and limit the processing that is applied to
ED

03

SC.2:Introduction
3AL 98253 ADAA

12/15

them.
Flushing:
This deals with logs. When a log is flushed, all its records are deleted.
Functional Access Domain:
It defines the range of functions which are available to a specified user.
Gigabits per second:
Unit that corresponds to the transmission of 10 9 bits every second.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Gateway Network Element:


It is a Network Element devoted to the control, from the OS, of those NEs providing a QECC* interface. To
do this it uses a QB3* interface and performs the conversion QB3* .QECC*.
Human Machine Interface:
It is the graphical user interface application through which the operators interact with the system.
History Report:
This function enables operators to get information concerning performances, security or alarms on entities
composing the network, or on the network itself. The operator specifies the time period for which he requires
the report.
International Telegraph and Telephone Consultative Committee:
Standard organization for telecommunications. Now called the ITUT (International Telecommunication
Union).
Kilobits per second:
Unit that correspond to the transmission of 10 3 bits every second.
Line Terminal:
A line terminal is the end point of a communication link. it is used to transmit or receive signals. They can
undertake signal conversion functions (adapting a signal to two different transmission media) or
multiplexing/demultiplexing functions.
Logs:
Logs are files used to store history data concerning the incoming notifications, operator commands and
system alarms. The size of the log can be configured.
Management Domain:
The Craft Terminal product is partitioned into management domains for functional proposes. Each
management domain is associated with functionalities that enable the operators to manage the NEs.
Media Access Control Address:
Represents the Level 2 address for Local Area Networks.
Megabits per second:
Unit that corresponds to the transmission of 10 6 bits every second.
Multiplexer:
Equipment used to combine several signals to produce a single signal at a higher transmission rate and to
decompose it back to the smaller rate signals.
Multiplex Section:

ED

03

SC.2:Introduction
3AL 98253 ADAA

13/15

In general, represents the section containing the multiplexed signals.


Network Access Domain:
Defined as a set of Network Elements. NADs are used to define the set of Network Elements that a user can
manage.
Network Element:
Either a telecommunication equipment or groups parts of a Telecommunication Network. Have
characteristics compliant with CCITT recommendations.
Network Management Level:
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

Designates the management functions performed on networks elements assembled in a network.


Notification:
Spontaneous data received by the system concerning an NE.
Operation System:
A system dedicated to the supervision of NEs in a standard way, using protocols and interfaces. it offers to
the operator a set of functions necessary to supervise the NEs. The 1353SH is an Operation System.
Operator:
The enduser of the Craft Terminal. He supervises a part of the network that is dependant on his user profile.
Physical Interface:
Electrical or Electrical/Optical transformers that decouples the line signals and adapt the form of signal for
further transmission. This functional block also manages clock extraction, signal loss monitoring and
loopback functions.
Port:
A physical point at which the Network Element can be attached to a transmission medium. A port is either a
termination point or an origination point.
Repeater:
Equipment used to regenerate a signal when it has travelled a long distance.
Severity:
Linked to alarms, severities indicate the magnitude related to the failure.
Telecommunication Management Network:
Defines the concept of interoperable management of TNs. They provide an organized network structure to
achieve the interconnection of the different components of the TN and the services to process the
information.
Telecommunication Network:
Describes the network to be managed. Provides the transmission, the transport and the switching supports
to the interconnected Network Elements.
Terminal Point:
Describes either the origin or the termination of a signal in equipment. Is related to a port.
Thresholding:
This is the assignment of a specified value to monitored parameters (for example Bit Error Rates) that, when
exceeded, generate trouble indications.

ED

03

SC.2:Introduction
3AL 98253 ADAA

14/15

User Profile:
Identifies the functionalities of the Craft Terminal to which a user has access. A finite number of predefined
user profiles is determined by a fixed set of FADs. To give user access to Craft Terminal functionality, the
administrator must assign a profile to a UNIX user account by choosing one among the predefined profiles
installed with Craft Terminal.
User Service Manager:
These are presentation processes used by the Craft Terminal to manage the Human Machine Interface and
facilitate the interaction with the product.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Wrapping:
Wrapping is the technique that enables the most recent entries in a file to replace the oldest when a file is full.

END OF DOCUMENT

ED

03

SC.2:Introduction
3AL 98253 ADAA

15/15

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alcatel 1662SMC Rel2.4 Operator Handbook

Alcatel 1662SMC Rel2.4


NE Management

03

09/01/2006

Creation

ED

DATE

CHANGE NOTE

Distribution: Internal

Chen Yu
APPROVED BY

PREPARED BY

External

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

1/396

LIST OF FIGURES AND TABLES ..................................................................................................................10


1

INTRODUCTION .....................................................................................................................................21
1.1
1.1.1

Document scope.........................................................................................................................21

1.1.2

Target audience..........................................................................................................................21

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.2

Scope21

Terminology21

1.2.1

Acronyms and abbreviations ......................................................................................................21

1.2.2

Glossary of terms........................................................................................................................21

GENERAL INTRODUCTION ON VIEWS AND MENUS.........................................................................22


2.1

EML--USM view organization 22

2.2

Introduction on the EML--USM menu options23

2.2.1

Views menu introduction.............................................................................................................25

2.2.2

Configuration menu introduction.................................................................................................25

2.2.3

Diagnosis menu introduction ......................................................................................................26

2.2.4

Supervision menu introduction ...................................................................................................27

2.2.5

MS-SPRing menu introduction ...................................................................................................27

2.2.6

Download menu introduction ......................................................................................................27

2.2.7

Equipment menu introduction .....................................................................................................28

2.2.8

Board menu introduction.............................................................................................................28

2.2.9

Port menu introduction................................................................................................................28

2.2.10

EPS menu introduction...........................................................................................................30

2.2.11

Transmission menu introduction ............................................................................................30

2.2.12

Synchronization menu introduction ........................................................................................32

2.2.13

External Points menu introduction..........................................................................................33

2.3
3

Advices on Navigation principles 37

NE MANAGEMENT SUPERVISION .......................................................................................................40


3.1

NE management states40

3.2

NE supervision and login 40

NE MANAGEMENT GENERAL CONFIGURATION ..............................................................................42


4.1

Access state (allow or inhibit NE Craft access)42

4.1.1

Switching from the OS to the Craft Terminal access state.........................................................42

4.1.2

Switching from the Craft Terminal access state back to the OS access state ...........................43

4.2

NE Time management43

4.3

Alarm Configuration 45

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

2/396

4.3.1

Procedure to modify an ASAP ....................................................................................................45

4.3.2

Alarm Severity Assignment Profile Management (ASAP) ..........................................................45

4.3.3

Set SdhNE Alarms Severities .....................................................................................................50

4.3.4

Allow/Inhibit Alarms Notifications................................................................................................51

4.3.5

Alarms resynchronization........................................................................................................52

4.3.6

Alarms persistency Configuration ...............................................................................................53

4.4

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Restart NE54

SECURITY MANAGEMENT ...................................................................................................................55


5.1

Set Manager list55

5.2

Set ACD level55

EXTERNAL INPUT AND OUTPUT POINTS MANAGEMENT ...............................................................57


6.1

Displaying external points 57

6.1.1
6.2
7

Expanding or reducing external points list..................................................................................59


External points configuration 59

DIAGNOSIS MANAGEMENT .................................................................................................................62


7.1

Alarms surveillance 62

7.2

Abnormal Condition List 64

7.3

Internal Link Monitor65

7.4

Log Browsing 66

7.5

Remote Inventory67

7.5.1

Upload remote Inventory ............................................................................................................67

7.5.2

View Remote Inventory...............................................................................................................68

COMMUNICATION AND ROUTING MANAGEMENT............................................................................70


8.1

Overview on Communication and Routing Domain 70

8.1.1

OSI Protocol on QB3/Qecc.........................................................................................................70

8.1.2

Partitioning into separate Routing Domains ...............................................................................71

8.1.3

IP over OSI tunneling for ATM/IP ...............................................................................................72

8.1.4

OSI over IP tunneling on QB3 ....................................................................................................72

8.2

Communication and routing views 73

8.3

Local Configuration 75

8.4

OS Configuration 76

8.5

NTP Server Configuration 77

8.6

LAPD Configuration79

8.7

Ethernet Configuration 82

8.8

Reachable Address Prefixes Configuration 84

8.9

Manual ES Adjacencies table Configuration85

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

3/396

8.10

IP Configuration 86

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

8.10.1

IP routing configuration for ATM/IP boards management ......................................................86

8.11

IP Static Routing Configuration87

8.12

OSPF Area Table Configuration 88

8.13

IP Address Configuration of Point-to-Point Interfaces 89

8.14

ISA board IP Address 90

8.15

OSI over IP 91

8.16

IP over OSI 91

Equipment Management .......................................................................................................................93


9.1

Introduction and navigation93

9.2

Set and change or remove board/subrack 98

9.3

Connect Fan to CONGI board 102

9.4

Board administrative state 103

9.4.1

Setting a board in service .........................................................................................................103

9.4.2

Setting a board out of service ...................................................................................................103

9.4.3

Consulting a Board's Administrative state ................................................................................104

9.5

Software description104

9.6

Remote Inventory105

9.7

Show supporting equipment108

10

BOARD VIEW........................................................................................................................................109
10.1

Introduction 109

10.2

Board View Menu 111

11

10.2.1

Port Access ..........................................................................................................................111

10.2.2

Change Physical Interface ...................................................................................................112

10.2.3

Show supporting equipment.................................................................................................113

PORT VIEW...........................................................................................................................................114
11.1

Introduction 114

11.2

Port View: elements on the TP 115

11.3

Port View Menu 117

11.4

Set Retiming 117

11.5

AU4 Concatenation 119

11.6

Physical Media option menu122

ED

11.6.1

Automatic Laser Shutdown Configuration............................................................................123

11.6.2

Show Optical Configuration..................................................................................................126

11.6.3

Single Fibber Configuration..................................................................................................127

11.6.4

Ms Configuration ..................................................................................................................128

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

4/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

11.6.5

Line Length Configuration ....................................................................................................129

11.6.6

Ethernet Port Configuration..................................................................................................129

11.6.7

Ethernet Mapping Protocol...................................................................................................132

11.6.8

Control Path Activation.........................................................................................................132

11.6.9

LCAS Configuration..............................................................................................................134

11.7

TP Frame Mode Configuration138

11.8

Show Supporting Board 141

11.9

Navigate to Transmission View 142

11.10

Navigate to Monitoring View 143

11.11

Port Mode Overview145

12

Equipment Protection management (EPS) .......................................................................................148


12.1

Introduction 148

12.2

Management: consulting and modifying EPS148

12.3

Configuration: revertive and WTR for EPS153

12.4

Switching EPS 155

12.5

EPS Overview 156

13

Multiplex Section Protection Management .......................................................................................161


13.1

Architecture types161

13.2

MSP Options Introduction161

13.3

MSP Create 162

13.4

MSP Management 165

13.4.1

MSP modification..................................................................................................................166

13.5

MSP Delete167

13.6

Display of Protection State 168

13.7

MSP Commands170

13.8

MSP overview 172

14

TRANSMISSION VIEW .........................................................................................................................177


14.1

Overview 177

14.2

View elements 178

14.3

View Layout 178

14.3.1

View Description...................................................................................................................178

14.3.2

Number of TPs Displayed in Transmission View .................................................................179

14.3.3

Naming TPs..........................................................................................................................179

14.3.4

Dynamic View Behaviour .....................................................................................................180

14.4

Transmission view access and menu180

14.5

Add TP181

14.5.1
ED

03

TP Search.............................................................................................................................182
SC.3: NE MANAGEMENT
3AL 98253 ADAA

5/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

14.6

TP Configuration 188

14.6.1

High Order TP Configuration................................................................................................188

14.6.2

J0 Section Trace management ............................................................................................191

14.6.3

Low Order TP Configuration.................................................................................................191

14.7

TP Frame Mode Configuration194

14.8

TP Threshold Configuration195

14.9

Terminate/Disterminate TP196

14.9.1

Terminate TP........................................................................................................................196

14.9.2

Disterminate TP....................................................................................................................196

14.10

Monitoring Operations197

14.10.1

Creation/Deletion..................................................................................................................197

14.10.2

Configuration ........................................................................................................................199

14.11

Structure TPs201

14.12

Loopback 202

14.12.1

Loopback Configuration .......................................................................................................202

14.12.2

Loopback Management........................................................................................................204

14.13

Physical Media 207

14.13.1
14.14

15

Set Domain...........................................................................................................................208

Navigation Commands 209

14.14.1

Expand .................................................................................................................................209

14.14.2

Hide ......................................................................................................................................209

14.14.3

Show Supported Board ........................................................................................................210

14.14.4

Navigate to Port View...........................................................................................................211

14.14.5

Navigate to HOA Port...........................................................................................................213

Cross-Connection Management.........................................................................................................214
15.1

Introduction 214

15.1.1

Overview...............................................................................................................................214

15.1.2

Multiplex Structures for SDH ................................................................................................214

15.1.3

Definition of Termination Points (TP) ...................................................................................217

15.1.4

Mapping Tables: TP Names.................................................................................................221

15.1.5

Cross-Connection Types......................................................................................................222

15.1.6

Cross-Connection Protection ...............................................................................................224

15.2

Operative Sequence to execute Cross-Connections 226

15.3

Cross-Connections management228

ED

15.3.1

Search Criteria......................................................................................................................230

15.3.2

Cross-Connection List ..........................................................................................................232

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

6/396

15.3.3
15.4

Create/Modify Cross-Connections 234

15.4.1

Cross-Connection Parameters .............................................................................................236

15.4.2

Create a Cross-Connection..................................................................................................240

15.4.3

Modify a Cross-Connection ..................................................................................................245

15.5

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Actions available...................................................................................................................234

Activate/Deactivate/Delete Cross-Connections 248

15.5.1

Activate a Cross-Connection................................................................................................248

15.5.2

Deactivate a Cross-Connection............................................................................................248

15.5.3

Delete a Cross-Connection ..................................................................................................249

15.6

Split and Join Cross-Connections 249

15.6.1

Split a Cross-Connection......................................................................................................249

15.6.2

Join Two Cross-Connections ...............................................................................................251

15.7

Protection Switching 252

15.8

Print 253

15.9

Show Cross-Connected TPs 254

16

OVERHEAD MANEGEMENT ...............................................................................................................256


16.1

Introduction 256

16.2

OH Connection overview256

16.3

Overhead views257

16.4

OH Cross Connection258

16.5

OH TP creation 262

16.6

OH TP deleting 264

16.7

OH Phone Parameters 265

17

Performance Monitoring .....................................................................................................................266


17.1

ED

Introduction 266

17.1.1

Overview...............................................................................................................................266

17.1.2

Supported Performance Counters........................................................................................266

17.1.3

Far End (FE) and Near End (NE) Performance Counting....................................................267

17.1.4

Bidirectional Counting (24 h Bi) for QoS ..............................................................................268

17.1.5

End to End (e-e 24h) Performance Counting.......................................................................268

17.1.6

Performance Monitoring on AU-PJE ....................................................................................269

17.1.7

Tandem Connection Termination (TCT) and Monitoring (TCM) ..........................................269

17.1.8

Performance Monitoring on 2 Mbit/s ISDNPRA .................................................................269

17.1.9

Performance Data Collection ...............................................................................................269

17.1.10

Data Collection .....................................................................................................................270

17.1.11

Performance Monitoring History...........................................................................................271

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

7/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

17.1.12

Thresholds............................................................................................................................271

17.2

Configuration ( SDH Port ) 272

17.3

Performance Monitoring on ETHRNET port 275

17.3.1

Overview...............................................................................................................................276

17.3.2

Ethernet physical interface counters ....................................................................................277

17.3.3

Aggregate counter ................................................................................................................277

17.3.4

Flow counter .........................................................................................................................278

17.4

Display Current Data ( SDH Port ) 279

17.5

Display History Data ( SDH Port )281

17.6

PM Threshold Table Selection ( SDH Port )284

17.7

PM Threshold Table Creation / Modification / Display ( SDH Port )286

17.7.1

Creation ................................................................................................................................286

17.7.2

Modification ..........................................................................................................................288

17.7.3

Display..................................................................................................................................288

17.8

Configuration (Ethernet port)289

17.9

Display current Data (Ethernet port) 290

17.10

Display history Data (Ethernet port) 292

17.11

PM Overview293

18

Synchronization management............................................................................................................297
18.1

Introduction 297

18.2

Synchronization Management 299

19

18.2.1

Displaying the Synchronization View ...................................................................................299

18.2.2

Synchronization View ...........................................................................................................300

18.2.3

Timing Source Configuration................................................................................................302

18.2.4

Synchronization Protection Commands ...............................................................................305

18.2.5

Synchronization Configuration for T0/T4 and T4 squelch criteria ........................................306

18.2.6

SSU Configuration................................................................................................................307

18.2.7

Remove Timing Reference...................................................................................................308

18.2.8

Change T4 <-> T5 ................................................................................................................309

18.2.9

Change 2MHz ->2Mbit .........................................................................................................311

18.2.10

Set and Remove T0 Equal T4 ..............................................................................................313

18.2.11

Transmission of SSM Quality Configuration ........................................................................313

18.2.12

Show Timing Source ............................................................................................................314

MS-SPRING MANAGEMENT ...............................................................................................................315


19.1

MS-SPRING introduction315

19.2

MS-SPRING connection configuration advices 315

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

8/396

19.2.1
19.3

Operative sequence to configure MS-SPRING315

19.3.1
19.4

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Operative sequence to configure 2-Fiber MS-SPRING .......................................................315

MS-SPRING Management316

19.4.1

MS-SPRing Main Configuration ...........................................................................................317

19.4.2

Squelching table with 2 fiber Terrestrial applications ...........................................................321

19.4.3

Activate, Deactivate and Delete commands ........................................................................327

19.5

20

2-Fiber MS-SPRING connection configuration advices .......................................................315

MS-SPRING Protection Status and Commands for 2 fiber terrestrial application 328

19.5.1

2F MS-SPRing protection commands ..................................................................................328

19.5.2

External commands (2F) ......................................................................................................329

19.5.3

2F MS-SPRing dual protection commands ..........................................................................336

19.5.4

2F Protection Status Visualization........................................................................................340

ISA/IP/ETH CONFIGURATION.............................................................................................................362
20.1

Introduction 362

20.2

ATM/PR_EA/Ethernet board TTPs creation362

21

20.2.1

ATM boards ..........................................................................................................................362

20.2.2

PR_EA boards......................................................................................................................365

20.2.3

10/100 Mbit/s fast ETHERNET board ..................................................................................368

20.2.4

Gigabit/s ETHERNET board.................................................................................................372

20.2.5

ES1-8FE boards ...................................................................................................................373

20.2.6

ES4-8FE boards ...................................................................................................................376

20.2.7

ISA-ES16 board....................................................................................................................379

Software Management.........................................................................................................................382
21.1

Generalities and descriptions382

21.1.1
21.2

Naming Conventions ............................................................................................................382

Software download operative sequence 383

21.2.1

Software Download upgrade ................................................................................................383

21.2.2

NE Software package installation procedure .......................................................................384

21.2.3

Procedure .............................................................................................................................384

21.3

Software Download Manager menu 391

21.4

Init download 392

21.5

SW package Activation and Units information 393

21.6

Mib management395

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

9/396

LIST OF FIGURES AND TABLES

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

FIGURES
Figure 1.

EML--USM main view organization ............................................................................................23

Figure 2.

Menu options flow chart -- 1 .......................................................................................................34

Figure 3.

Menu options flow chart 2........................................................................................................35

Figure 4.

Menu options flow chart 3........................................................................................................36

Figure 5.

Menu options flow chart 4........................................................................................................37

Figure 6.

NE EML-USM Main view ............................................................................................................41

Figure 7.

NE management: setting the access state. ................................................................................42

Figure 8.

Consulting and/or setting the local NE time................................................................................43

Figure 9.

NE Time dialogue box ................................................................................................................44

Figure 10.

Configuring Alarm Severity Assignment Profile..........................................................................46

Figure 11.

ASAPs Management dialogue box.............................................................................................47

Figure 12.

ASAP Edition dialogue box.........................................................................................................48

Figure 13.

Set ASAP dialogue box. .............................................................................................................49

Figure 14.

Set SdhNE Alarms Severities .....................................................................................................51

Figure 15.

Inhibit alarm notification ..............................................................................................................51

Figure 16.

Allow alarm notifications .............................................................................................................52

Figure 17.

Alarm re--synchronization...........................................................................................................52

Figure 18.

Alarms persistency Configuration Menu option ..........................................................................53

Figure 19.

Alarm persistency Time Configuration........................................................................................53

Figure 20.

Restart NE confirmation..............................................................................................................54

Figure 21.

Set Manager list..........................................................................................................................55

Figure 22.

Set ACD level..............................................................................................................................56

Figure 23.

Opening the external points view................................................................................................57

Figure 24.

External points view....................................................................................................................58

Figure 25.

Expanding or reducing the external points list............................................................................59

Figure 26.

Configuring external points. ........................................................................................................59

Figure 27.

External input point configuration dialogue box..........................................................................60

Figure 28.

External output point configuration dialogue box (MANUAL) .....................................................60

Figure 29.

External output point configuration dialogue box (FLEXIBLE) ...................................................61

Figure 30.

Alarm Surveillance Menu............................................................................................................62

Figure 31.

Alarm Surveillance......................................................................................................................63

Figure 32.

Abnormal condition menu option ................................................................................................64

Figure 33.

Example of abnormal condition list.............................................................................................64

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

10/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 34.

Example of loopback dialog window management.....................................................................65

Figure 35.

Internal Link Monitor ...................................................................................................................66

Figure 36.

Log Browsing option in Network Element context view..............................................................66

Figure 37.

Remote Inventory confirmation request......................................................................................67

Figure 38.

Remote Inventory completed......................................................................................................67

Figure 39.

View Remote Inventory...............................................................................................................68

Figure 40.

Routing sub domain organization example ................................................................................71

Figure 41.

OSI over IP tunneling on QB3 ....................................................................................................73

Figure 42.

Comm/Routing options ...............................................................................................................74

Figure 43.

Local Configuration.....................................................................................................................76

Figure 44.

OS Configuration ........................................................................................................................77

Figure 45.

NTP Server Configuration...........................................................................................................78

Figure 46.

Creation LAPD Interface.............................................................................................................80

Figure 47.

TP search dialog.........................................................................................................................80

Figure 48.

LAPD Configuration dialog .........................................................................................................81

Figure 49.

Confirmation to change LAPD Role............................................................................................81

Figure 50.

Ethernet Configuration................................................................................................................83

Figure 51.

Ethernet Configuration -- L2 only parameter ..............................................................................84

Figure 52.

RAP Configuration ......................................................................................................................85

Figure 53.

MESA Configuration ...................................................................................................................86

Figure 54.

IP Static Routing Configuration...................................................................................................88

Figure 55.

OSPF Area Table Configuration .................................................................................................89

Figure 56.

IP Address Configuration of Point-to-Point Interfaces ................................................................89

Figure 57.

ISA Board IP Address.................................................................................................................90

Figure 58.

OSI over IP Tunneling configuration...........................................................................................91

Figure 59.

IP over OS ..................................................................................................................................92

Figure 60.

Equipment Overview -- Subracks level.......................................................................................94

Figure 61.

Equipment Overview -- Rack level (without Fans subrack)........................................................95

Figure 62.

Equipment Overview- Rack level (with Fans subrack) ...............................................................96

Figure 63.

Equipment Overview - NE level ..................................................................................................97

Figure 64.

Equipment menu.........................................................................................................................98

Figure 65.

The list of different boards relative to an NE slot (example).......................................................99

Figure 66.

Modify the module ....................................................................................................................101

Figure 67.

The list of different types of optical module (example) .............................................................101

Figure 68.

Connect FAN to CONGI ...........................................................................................................102

Figure 69.

Remove FAN connection from CONGI.....................................................................................103

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

11/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 70.

Consulting a boards administrative state.................................................................................104

Figure 71.

Software Description dialogue box. ..........................................................................................105

Figure 72.

Remote Inventory menu ...........................................................................................................105

Figure 73.

Remote Inventory dialogue box ................................................................................................106

Figure 74.

Select Printer ............................................................................................................................106

Figure 75.

Select Output Format for file.....................................................................................................107

Figure 76.

Equipment Overview -- Subrack level ......................................................................................108

Figure 77.

Equipment view: select the SDH port on a board.....................................................................109

Figure 78.

Example of a Board View .........................................................................................................110

Figure 79.

Example of a Port identification and alarm synthesis ...............................................................110

Figure 80.

Board menu options..................................................................................................................111

Figure 81.

After Port Access selection (example) ...................................................................................112

Figure 82.

Change Physical Interface........................................................................................................112

Figure 83.

Change Physical Interface dialog box ......................................................................................113

Figure 84.

Subrack level ............................................................................................................................113

Figure 85.

Example of a SDH Port View....................................................................................................115

Figure 86.

Termination TP box. .................................................................................................................116

Figure 87.

G.783 Adaptation TP box. ........................................................................................................116

Figure 88.

Examples of port menu options (SDH, PDH and ATM port) ....................................................117

Figure 89.

Set Retiming enable (before)....................................................................................................118

Figure 90.

Set Retiming enable (after).......................................................................................................119

Figure 91.

AU4 concatenate/deconcatenate commands...........................................................................120

Figure 92.

Example of a concatenated AU4 transmission view.................................................................121

Figure 93.

Example of a concatenated AU4c ............................................................................................122

Figure 94.

Physical media menu (SDH port example)...............................................................................123

Figure 95.

Automatic Laser Shutdown Management.................................................................................124

Figure 96.

Automatic Laser Shutdown Management (after ALS Function delete) ....................................125

Figure 97.

ALS and Laser current state (example)....................................................................................126

Figure 98.

Visualizing a port optical parameters........................................................................................126

Figure 99.

Bidirectional Transmission on a single fiber .............................................................................127

Figure 100.

Single Fiber Configuration View ...........................................................................................128

Figure 101.

Ms Configuration ..................................................................................................................128

Figure 102.

PDH Line Length Configuration View...................................................................................129

Figure 103.

Ethernet Port Configuration options .....................................................................................129

Figure 104.

Ethernet Port Configuration Dialog.......................................................................................130

Figure 105.

Information dialog .................................................................................................................130

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

12/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 106.

Gigabit Ethernet port view (example) ...................................................................................131

Figure 107.

Ethernet Mapping Protocol (EXAMPLE) ..............................................................................132

Figure 108.

Control Path Activation (example on Fast Ethernet board)..................................................133

Figure 109.

Control Path Activation:Range Path mode...........................................................................134

Figure 110.

LCAS Configuration..............................................................................................................136

Figure 111.

LCAS Monitoring ..................................................................................................................136

Figure 112.

TP Frame Mode Configuration .............................................................................................139

Figure 113.

Board View Example ............................................................................................................141

Figure 114.

Navigate to Transmission view selection...........................................................................142

Figure 115.

After Navigate to Transmission view selection ..................................................................143

Figure 116.

View of Monitoring Operations (example) ............................................................................144

Figure 117.

Port Mode Menu Option .......................................................................................................145

Figure 118.

Port Mode Overview Dialog..................................................................................................145

Figure 119.

set the selected port mode ...................................................................................................147

Figure 120.

Consulting EPS ....................................................................................................................149

Figure 121.

EPS Management dialogue box...........................................................................................149

Figure 122.

EPS: board selection ............................................................................................................152

Figure 123.

EPS: choose protected.........................................................................................................153

Figure 124.

EPS functional state from protected active board view........................................................153

Figure 125.

EPS functional state from protecting active board view .......................................................153

Figure 126.

Configure EPS......................................................................................................................153

Figure 127.

EPS Management dialogue box...........................................................................................154

Figure 128.

Switching EPS ......................................................................................................................155

Figure 129.

EPS Switch dialogue box .....................................................................................................155

Figure 130.

EPS overview .......................................................................................................................156

Figure 131.

EPS overview after Search (Example) .................................................................................157

Figure 132.

Subrack view after Open Subrack View command............................................................159

Figure 133.

Board view after Open Board View command...................................................................160

Figure 134.

MSP Create Option ..............................................................................................................162

Figure 135.

MSP Schema Creation.........................................................................................................162

Figure 136.

MSP schema creation Port dialog ........................................................................................163

Figure 137.

TP Search.............................................................................................................................164

Figure 138.

MSP 1+1 standard protection schema (example)................................................................165

Figure 139.

MSP Management Option ....................................................................................................165

Figure 140.

MSP Management View.......................................................................................................166

Figure 141.

MSP Delete option................................................................................................................167

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

13/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 142.

MSP Schema Deletion .........................................................................................................167

Figure 143.

MSP Protection Status Examples ........................................................................................169

Figure 144.

MSP Commands option .......................................................................................................170

Figure 145.

MSP Commands ..................................................................................................................171

Figure 146.

MSP overview.......................................................................................................................172

Figure 147.

MSP overview after Search (Example) ................................................................................174

Figure 148.

Port view after Open Port View commands .......................................................................176

Figure 149.

Symbols Used in Transmission View ...................................................................................178

Figure 150.

Transmission View Area.......................................................................................................179

Figure 151.

Transmission menu options .................................................................................................181

Figure 152.

TP Search Dialog, Initial State .............................................................................................182

Figure 153.

Information Window..............................................................................................................182

Figure 154.

TP Search Dialog with Various TP Selections .....................................................................183

Figure 155.

TP Search Dialog with Status Information Displayed...........................................................184

Figure 156.

Symbols in TP Search..........................................................................................................184

Figure 157.

Board History Check List......................................................................................................184

Figure 158.

TP Search Dialog with Different Filtering Options................................................................186

Figure 159.

Information... Dialog for Search Process ...........................................................................186

Figure 160.

Print to Printer.......................................................................................................................187

Figure 161.

Print to File ...........................................................................................................................187

Figure 162.

Example Printout ..................................................................................................................188

Figure 163.

High Order TP Configuration................................................................................................189

Figure 164.

J1 hexadecimal editor (example) .........................................................................................190

Figure 165.

J0 Configuration ...................................................................................................................191

Figure 166.

Low Order TP Configuration.................................................................................................192

Figure 167.

J2 hexadecimal editor ..........................................................................................................192

Figure 168.

TP Frame Mode Configuration .............................................................................................194

Figure 169.

Degraded Signal Threshold selection ..................................................................................195

Figure 170.

Monitoring Operations ..........................................................................................................197

Figure 171.

Monitoring Operations Creation/Deletion .............................................................................198

Figure 172.

Display of POM and TCM in Port View (example) ...............................................................199

Figure 173.

Display of POM and TCM/TCT in Port View (example) .......................................................199

Figure 174.

Monitor Configuration ...........................................................................................................200

Figure 175.

Structure TPs option.............................................................................................................201

Figure 176.

Loopback configurations ......................................................................................................202

Figure 177.

Port Loopback Configuration................................................................................................203

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

14/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 178.

Port Loopbacks View............................................................................................................204

Figure 179.

Loopback Management view................................................................................................205

Figure 180.

Loopback Management........................................................................................................205

Figure 181.

Loopback Port View..............................................................................................................206

Figure 182.

Loopback Transmission View...............................................................................................206

Figure 183.

Physical Media options.........................................................................................................207

Figure 184.

Set Domain...........................................................................................................................208

Figure 185.

Expand option.......................................................................................................................209

Figure 186.

Hide option ...........................................................................................................................210

Figure 187.

Board View ...........................................................................................................................211

Figure 188.

Port View ..............................................................................................................................212

Figure 189.

Navigate to HOA Port...........................................................................................................213

Figure 190.

SDH Multiplex Structure according to ITU-T G.709 .............................................................215

Figure 191.

Frame Construction within the Synchronous Digital Hierarchy............................................216

Figure 192.

SDH Transport Level Diagram .............................................................................................220

Figure 193.

PDH Transport Level Diagram .............................................................................................221

Figure 194.

Unidirectional Connection ....................................................................................................223

Figure 195.

Bidirectional Connection.......................................................................................................223

Figure 196.

Example of Broadcast Connection with Three Legs ............................................................223

Figure 197.

Bidirectional Connection - Input Protected...........................................................................224

Figure 198.

Bidirectional Connection - Input Protected...........................................................................224

Figure 199.

Protected Broadcast.............................................................................................................225

Figure 200.

Drop and Continue - Normal ................................................................................................225

Figure 201.

Cross connection management cascade menu ...................................................................229

Figure 202.

Cross-Connection Management Dialog (Initial State) ..........................................................231

Figure 203.

Cross-Connection Management Dialog (After Search)........................................................233

Figure 204.

Create Cross-Connections ...................................................................................................235

Figure 205.

Protection Criteria.................................................................................................................237

Figure 206.

Cross-Connection Icons .......................................................................................................239

Figure 207.

Creation of a Unidirectional, Non-Protected Cross-Connection...........................................239

Figure 208.

Create a Bidirectional Protected Cross-Connection.............................................................241

Figure 209.

Search for Cross-Connection Output ...................................................................................243

Figure 210.

Create an Unprotected Broadcast Cross-Connection..........................................................244

Figure 211.

Create a Protected Broadcast Cross-Connection ................................................................245

Figure 212.

Unprotect a Unidirectional Cross-Connection ......................................................................247

Figure 213.

Protect one Leg of a Broadcast Connection ........................................................................248

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

15/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 214.

Split/Join Unprotected Bidirectional Cross-Connection........................................................250

Figure 215.

Split/Join to Protected Bidirectional Cross-Connection........................................................250

Figure 216.

Protection Actions Dialog .....................................................................................................252

Figure 217.

Select Printer ........................................................................................................................253

Figure 218.

Select Output Format ...........................................................................................................253

Figure 219.

Show Cross Connected TPs view ........................................................................................254

Figure 220.

Show Cross Connected VC4 of an AU4 ..............................................................................255

Figure 221.

Overhead options .................................................................................................................257

Figure 222.

Cross Connection Management for Overhead dialog ..........................................................258

Figure 223.

Main Cross-Connection for Overhead dialog .......................................................................259

Figure 224.

OH TP creation.....................................................................................................................262

Figure 225.

OH Search TP for creation ...................................................................................................263

Figure 226.

OH TP deleting .....................................................................................................................264

Figure 227.

Phone Parameters dialog window........................................................................................265

Figure 228.

Far End Performance Monitoring Principles ........................................................................268

Figure 229.

Configure Monitoring. ...........................................................................................................272

Figure 230.

PM Configuration Dialog (example) .....................................................................................273

Figure 231.

PM question dialog box (example) .......................................................................................274

Figure 232.

Counter directionality: network centric view .........................................................................276

Figure 233.

Counter subdivision ..............................................................................................................277

Figure 234.

Ethernet aggregate counter..................................................................................................278

Figure 235.

Display Current Data view....................................................................................................279

Figure 236.

Current PM Data Dialog (example) ......................................................................................281

Figure 237.

PM History Data view ...........................................................................................................282

Figure 238.

PM History Data Dialog (example) .......................................................................................283

Figure 239.

PM Configuration dialog .......................................................................................................284

Figure 240.

PM Threshold Table Select ..................................................................................................285

Figure 241.

PM Port View........................................................................................................................286

Figure 242.

PM Transmission View .........................................................................................................286

Figure 243.

Create PM Threshold Table .................................................................................................287

Figure 244.

Modify PM Threshold Table .................................................................................................289

Figure 245.

PM Configuration dialog .......................................................................................................290

Figure 246.

Create Ethernet counter .......................................................................................................290

Figure 247.

Display Current Data ............................................................................................................291

Figure 248.

Display current data..............................................................................................................291

Figure 249.

PM History Data dialog.........................................................................................................292

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

16/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 250.

Display History Data .............................................................................................................293

Figure 251.

PM Overview Menu item ......................................................................................................293

Figure 252.

PM Overview ........................................................................................................................294

Figure 253.

Add TP for PM Overview......................................................................................................295

Figure 254.

PM Overview after add TP ...................................................................................................296

Figure 255.

Internal organization of the SETS. .......................................................................................297

Figure 256.

Obtaining the synchronization view......................................................................................299

Figure 257.

Synchronization View Example ............................................................................................300

Figure 258.

Synchronization Menu..........................................................................................................302

Figure 259.

Timing source configuration for cross-Connect equipments................................................303

Figure 260.

Synch. Source configuration for ADM equipment ................................................................304

Figure 261.

Lockout, Force and Manual commands ...............................................................................305

Figure 262.

Configuring the T0 or T4 SSM algorithm and the squelch criteria .......................................307

Figure 263.

SSU Configuration................................................................................................................308

Figure 264.

Synchronization source removing ........................................................................................308

Figure 265.

Synchronization source removing confirmation ...................................................................309

Figure 266.

Change T4 <-> T5 menu ......................................................................................................309

Figure 267.

Change T4 <-> T5 confirmation message............................................................................310

Figure 268.

Change T4 <-> T5: command execution..............................................................................310

Figure 269.

Change 2MHz -->2Mbit menu ..............................................................................................311

Figure 270.

Change 2MHz ->2Mbit confirmation message .....................................................................311

Figure 271.

Change 2MHz -->2Mbit: command execution......................................................................312

Figure 272.

T4 equal T0 setting...............................................................................................................313

Figure 273.

Transmission SSM Quality ...................................................................................................314

Figure 274.

Timing Source Example .......................................................................................................314

Figure 275.

Display MSSPRing pull down menu...................................................................................316

Figure 276.

MS-SPRing Management dialog box ...................................................................................317

Figure 277.

Creation Schema dialog box ................................................................................................318

Figure 278.

Activated MS-SPRing Management.....................................................................................319

Figure 279.

Node Id and associated ring node position ..........................................................................319

Figure 280.

Ring map configuration ........................................................................................................320

Figure 281.

WTR dialog box ....................................................................................................................321

Figure 282.

Example of error message ...................................................................................................321

Figure 283.

Squelching table ...................................................................................................................322

Figure 284.

Example of a ring traffic........................................................................................................322

Figure 285.

Connections of the ring ........................................................................................................323

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

17/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 286.

Squelching table of Node A, West side ................................................................................323

Figure 287.

Squelching table of Node A, East side .................................................................................324

Figure 288.

Squelching table of Node B, West side ................................................................................324

Figure 289.

Squelching table of Node B, East side .................................................................................325

Figure 290.

Squelching table of Node C, West side................................................................................325

Figure 291.

Squelching table of Node C, East side.................................................................................326

Figure 292.

Squelching table of Node D, West side................................................................................326

Figure 293.

Squelching table of Node D, East side.................................................................................327

Figure 294.

Confirmation message .........................................................................................................327

Figure 295.

Protection states and commands "Idle" status (2F) .............................................................328

Figure 296.

Ring Protection (2F) .............................................................................................................329

Figure 297.

Lockout commands (2F).......................................................................................................329

Figure 298.

Protection and working channels where the lockout command can be activated (2F) ........330

Figure 299.

Tail-end / Head-end association...........................................................................................330

Figure 300.

Tail-end / head-end protection with a lockout working and a one direction failure (2F).......331

Figure 301.

Ring protection with a lockout and a ring failure (2F)...........................................................332

Figure 302.

Lockout command and non-served failures (2F)..................................................................333

Figure 303.

Forced and Manual Commands (2F) ...................................................................................334

Figure 304.

Manual and Force Span/Ring command (2F) ......................................................................334

Figure 305.

Ring Protection with Force and Manual commands (2F) .....................................................335

Figure 306.

Automatic protection Bridge/Switch (2F)..............................................................................336

Figure 307.

Example of confirmation dialog box .....................................................................................336

Figure 308.

Clear WTR command (2F) ...................................................................................................336

Figure 309.

Ring network reference scheme (2F) ...................................................................................337

Figure 310.

Examples of Double ring failure ...........................................................................................338

Figure 311.

Automatic protection (tail/head) for double ring failure visualization....................................339

Figure 312.

Tail / head dual "Events" Protection table (2F) ....................................................................340

Figure 313.

Manual command applied at the "Reference Point" ring network........................................342

Figure 314.

Visualization of the Forced / Manual protection Statuses (2F) ............................................343

Figure 315.

Visualization of the Lockout command Statuses (2F) ..........................................................344

Figure 316.

Visualization of Automatic Protection Statuses (2F) ............................................................345

Figure 317.

Protection status with double ring failure (reference point -SS-AN).....................................346

Figure 318.

Protection status with double ring failure (reference point-SS-RN) .....................................347

Figure 319.

Protection status with double ring failure (reference point-OS-AN) .....................................348

Figure 320.

Protection status with double ring failure (reference point-OS-AN) recovering to "idle" ......349

Figure 321.

Double manual ring command (reference point-SS-AN)......................................................351

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

18/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 322.

Double manual ring command (reference point-OS-AN) .....................................................352

Figure 323.

Manual ring and Lockout Protection (reference point-SS-SN).............................................353

Figure 324.

Manual ring and Lockout Protection (reference point-SS-RN).............................................355

Figure 325.

Automatic working ring and Manual Ring (reference point-OS-AN) ....................................357

Figure 326.

Automatic working ring and Force Ring (reference point-SS-AN) .......................................358

Figure 327.

Automatic working ring and Lockout working Ring (reference point-SS-SN).......................359

Figure 328.

Automatic working ring and Lockout Protection (reference point-OS-RN)...........................360

Figure 329.

ATM 4X4 MATRIX (initial empty fields) ................................................................................363

Figure 330.

ATM 4X4 MATRIX (with defined TPs)..................................................................................364

Figure 331.

Navigate to ATM port view (example) ..................................................................................365

Figure 332.

PR_EA MATRIX (initial empty fields) ...................................................................................366

Figure 333.

PR_EA MATRIX (with defined TPs) .....................................................................................367

Figure 334.

MPLS port view example......................................................................................................368

Figure 335.

ETHMB (initial empty fieds)................................................................................................369

Figure 336.

ETHMB (with defined TPs).................................................................................................370

Figure 337.

Control Path activation window (example) ...........................................................................371

Figure 338.

ETHERNET port view example ............................................................................................372

Figure 339.

ES1-8FE MATRIX (initial empty fields) ................................................................................374

Figure 340.

ES1-8FE MATRIX (with defined TPs) ..................................................................................375

Figure 341.

Navigate to ETH port view (example)...................................................................................376

Figure 342.

ES4-8FE MATRIX (initial empty fields) ................................................................................377

Figure 343.

ES4-8FE MATRIX (with defined TPs) ..................................................................................378

Figure 344.

Navigate to ETH port view (example)...................................................................................379

Figure 345.

ISA-ES16 MATRIX (initial empty fields) ...............................................................................380

Figure 346.

ISA-ES16 MATRIX (with defined TPs) .................................................................................380

Figure 347.

Navigate to ETH port view (example)...................................................................................381

Figure 348.

Software Download general principle...................................................................................382

Figure 349.

Software Administration menu .............................................................................................385

Figure 350.

Software Package Administration view ................................................................................385

Figure 351.

SDH software package installation.......................................................................................386

Figure 352.

ATM software package installation (example) .....................................................................387

Figure 353.

OMSN enhanced software package creation (part A)..........................................................388

Figure 354.

OMSN enhanced software package creation (part B)..........................................................389

Figure 355.

Enhanced software package (SDH + ATM) .........................................................................390

Figure 356.

Equipment view ....................................................................................................................391

Figure 357.

Download menu....................................................................................................................391

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

19/396

Figure 358.

SW Downloading dialogue box example..............................................................................392

Figure 359.

Software download in progress (example)...........................................................................393

Figure 360.

Software Package Information dialogue box (example).......................................................394

Figure 361.

Detail software package (example) ......................................................................................395

Figure 362.

NE MIB management ...........................................................................................................396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

TABLE
Table 1.

MSP commands and Auto-switch protection priority ....................................................................171

Table 2.

Default value for C2/V5 Signal Label ............................................................................................189

Table 3.

PDH TPs .......................................................................................................................................221

Table 4.

SDH TPs .......................................................................................................................................222

Table 5.

Optional and Mandatory Configurable Parameters for Cross-Connection Creation.....................238

Table 6.

Modifiable Parameters ..................................................................................................................246

Table 7.

Threshold table entities association..............................................................................................286

Table 8.

Maximum Performance Parameter Values ...................................................................................288

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

20/396

1
1.1
1.1.1

INTRODUCTION
Scope
Document scope

The aim of this document is to help the operator understand, configure and manipulate Network Elements
(NEs) easily, using the Craft Terminal (CT). The different functionalities related to the equipment views.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The menu items and the different actions that can be undertaken from these views are described in detail.
1.1.2

Target audience

This document is intended for the operators whose role is to manage the Network Elements.
The documents that should be read before starting this document are:
--- 1320CT Basic Operators Handbook
The documents of this Handbook that should be read before starting this document are:
--- Introduction manual

1.2
1.2.1

Terminology
Acronyms and abbreviations

Refer to the Section Introduction manual.


1.2.2

Glossary of terms

Refer to the Section Introduction manual.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

21/396

GENERAL INTRODUCTION ON VIEWS AND MENUS

In this chapter the organization of the EML--USM screen, presented after the NE login, is described.
First is introduced the view organization, then the accessible menu options are listed.
At the end some further advice are given for Navigation principles.

2.1

EML--USM view organization

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The EML--USM view (see Figure 1) is the first window presented to the operator after the login.
It contains the following fields, which provide you with information needed to manage the NE:
Severity alarm synthesis,
Domain alarm synthesis,
Management status control panel
View title,
View area
Message/state area
The Menu bar and the View area contained in the same NE view permits to perform all the configuration and
supervision and display the specific selected item.
The view organization is detailed in the Basic Craft Terminal Operator Handbook to which refer for the
description, except for the following information, that differs according the NE type:
-- Domain alarm synthesis
The different alarm domain type in which can be subdivided the NE is: Synchronization, External Point,
Equipment, and Transmission.
Information about the alarms and status is given in the Maintenance section of this handbook.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

22/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 1.

2.2

EML--USM main view organization

Introduction on the EML--USM menu options

The menu bar allows performing configuration and supervision functions on the Network Element.
This paragraph lists all the menu options and then more details on the relevant contained entries.
For each of them the relevant operative functions are briefly introduced.
The flow charts of Figure 2., Figure 3., Figure 4., Figure 5., summarize the menu options.
From chapter 3 on details and operative information on the all the views are given. They are not presented
according the menu option sequence but according a functional subdivision.
In the menu bar there are permanent menu items always displayed. Staring from the left, the menus are:

ED

Permanent Menus
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

23/396

Views (first column).


To navigate among the views and set TMN and Overhead parameters.

Configuration (second column).


To set general configuration of the NE, set TMN and Overhead parameters
and to show or modify some parameters (performance monitoring,
ATM/IP/ETH creation, MSP, EPS and cross-connection).

Diagnosis (third column).


To get information about the NE (alarms, performance monitoring, remote
inventory internal link monitor).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Supervision (fourth column).


To set the supervision states (i.e. Craft Terminal enabling).

MS_SPRing (fifth column)


To manage the 2-fiber MS_SPRing protection, setting the relevant configuration.

Download (sixth column).


To manage the NE software (download, MIB management).

Help (last column).


To activate the help.

Further, in the menu bar there are other menus, presented as an alternative, only when a particular object or
option is selected.

Other Menus

Equipment (eighth column).


To manage the NE as a whole, setting the boards, which compose it. From
the Equipment view the Board view can be accessed.
From the Equipment menu is also possible to start the Specific Terminal
application for the ATM/IP traffic configuration.

Board (eighth column).


To show the physical port available in a specific board. It is the entry point
for the Port view.

Transmission (seventh column).


It permits to show and set the Termination Point of the equipment, thus
having an overview of the complete signal flow of the various port.
The menu permits to define all the Cross Connections and manages the
transmission resources, setting the relevant configuration.
Further access the Performance Monitoring and permits navigation to the
Board view.
It also permits to manage the MSP protection setting the relevant
configuration.

Port (seventh column).


To set and show (detailed alarm view) the transmission resources referred
to the Port.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

24/396

It also permits to manage the MSP protection setting the relevant


configuration.

EPS (seventh column).


To manage the EPS protection, setting the relevant configuration.

Synchronization (seventh column).


To show and modify synchronization parameters.

External Points (seventh column).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To show and modify housekeeping (environmental) alarms.


2.2.1

Views menu introduction

This menu permits to navigate among the views and set some parameters, by means of the following entries:

Backward:

Go back to the previous view.

Forward:

Go to the next view.

Equipment:
Open the Equipment view. The "Equipment" menu and the "EPS" menu are
then available on the menu bar.

External Points:
on the menu bar.

Open the External Point view. The "External Point" menu is then available

Transmission:
the menu bar.

Open the Transmission view. The "Transmission" menu is then available on

Synchronization:
Open the Synchronization view. The "Synchronization" menu is then
available on the menu bar

Refresh:
The aim of the refresh feature is to avoid a misalignment between the CT
and the managed NE. This misalignment is due to a loss of notifications coming from the NE.

Open Object:
Navigate and show the contents of the selected object: the current view
change. It is equivalent to a double click on the selected object in the view area.

Open in Window:
Navigate and show the contents of the selected object. The current view
doesn't change but a new window with a new view is opened.

Close:

2.2.2

Close the EML-USM view, without stopping the supervision of the NE

Configuration menu introduction

This menu permits to set general configuration of the NE and to show or modify some parameters, by means
of the following entries:

Alarm Severities:

Manage the Alarm Severity Assignment Profile.

Set Alarm severities:

Send the Alarm Severity Assignment Profile to the selected object

Set SdhNe Alarm severities: Send the Alarm Severity Assignment Profile referred to the equipment
level.

NE Time:

Performance:
Manage the Performance Monitoring domain. Used to define the PM
parameters, opening the following menu options:

Display and set the NE local time.

- Threshold table

ED

EPS overview:

03

Allows displaying as well as search for EPS states.

SC.3: NE MANAGEMENT
3AL 98253 ADAA

25/396

Set ACD level:

Cross Connection Management: Manage the connection of the paths.

Loopback Management: Enter the loopback management. Used to configure the loopback command
for commissioning or maintenance purposes.

Comm/Routing: Enter the Communication and Routing management. Used to define the parameters
for NE and OS in the TMN, opening the following menu options:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Local configuration

OS Configuration

NTP Server Configuration

Interfaces Configuration

LAPD Configuration

Ethernet Configuration

OSI Routing Configuration


-

RAP Configuration

MESA Configuration

IP Configuration
-

IP Static Routing Configuration

OSPC Area Configuration

IP Address Configuration of point-to-point interfaces

ISA board IP address

Tunneling Configuration
-

OSI Over IP

IP over OSI

Overhead: Handle the operation on the Overhead bytes. Used to define the parameters in the following
menu options:
-

OH Cross Connection

OH Phone Parameter

OH TP creation

OH TP deleting

MSP overview:

Allows displaying as well as search for MSP states.

PM overview:

Allows displaying performance overview.

ISA Port Configuration:

It allows to create the TPs for the ATM/IP/ETH connections

2.2.3

Diagnosis menu introduction

This menu permits to get information about the NE, by means of the following entries:

ED

Alarms: Display the Alarms Surveillance information of the NE. It opens the following menu options:

03

NE alarms

Object alarms
SC.3: NE MANAGEMENT
3AL 98253 ADAA

26/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Subtree alarms

Equipment alarms

Transmission alarms

External Points alarms

Log Browsing: Manage the events stored in the NE. It opens the following menu options:
-

Alarm Log

Event Log

Software Trace Log

View Remote Inventory: Display the remote inventory data, previously stored in the Craft Terminal by
means the "upload remote inventory" performed in the "Supervisory" menu.

Abnormal Condition list Display the list of the object class (Loopback, ALS Handler, protection board)
and the name of the boards that are in abnormal condition.

Internal Link Monitor: Indicates the preference of failure on Rx or Tx side for the signal
incoming/outgoing from/to the active/standby MATRIX board.

Dataflow Analyzer.

2.2.4

Supervision menu introduction

This menu permits to set the supervision states of the NE, by means of the following entries:

Access State: Manage the supervision access to the NE, with CT or OS. It opens the following menu
options:
-

OS

Requested

Alarms: Manage the alarms supervision of the NE. It opens the following menu options:
-

Resynchronize.

Allow / Inhibits Notifs.

Upload Remote Inventory: Store the Remote Inventory data in the Craft Terminal.

Set Manager list

Restart NE: Reset the NE software.

2.2.5

MS-SPRing menu introduction

This menu permits to age the 2-fiber and 4-fiber MS-SPRing protection (the last is not operative in current
release), setting the relevant configuration, by means of the following entries:
Main dialog for MS-SPRing management: Contains all the command to set and manage the MS-SPRing
2.2.6

Download menu introduction

This menu permits to manage the NE software, by means of the following entries:

ED

Init download: Manage the software download, upgrading the NE.

Units info: Show the status of the software package installed in the NE memory banks.

Mib management: Permits backup of NE software configuration and restore of backup file.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

27/396

2.2.7

Equipment menu introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This menu permits to manage the NE as a whole, setting the boards, which compose it, by means of the
following entries:

Set: Add or change the board type (a list is proposed).

Modify: Change the board type without previously remove it. It is only possible between compatible
board or modules (ex. it is possible to change from an Long and Short 1.1 optical module)

Remove: Remove the board.

Set in service: Insert a lock symbol in the board.

Set out of service Delete the lock symbol in the board, enabling changes.

Reset: Not operative.

Software description: Show information on the software of the board.

Remote Inventory: Show the Remote Inventory data inserted in the equipment. It opens the following
menu options:

Subrack level

Board level

ISA Board IP Address: Used to define the ISA board IP address

N.B. This option is available only at Subrack view level.

Show supporting equipment: Navigate to the upper equipment level.

Connect FAN to CONGI #1: Enable the management of the Fan subrack alarms on CONGI inserted
in slot 1.

N.B. This option is available only after having selected a CONGI board at Subrack level view.

Connect FAN to CONGI # 20: Enable the management of the Fan subrack alarms on CONGI
inserted in slot 20.

N.B. This option is available only after having selected a CONGI board at Subrack level view.
2.2.8

Board menu introduction

This menu permits to show the physical port available in a specific board (alarm synthesis and port symbol)
and to access the port view, by means of the following entries:

Port Access: Access the "Port view".

Change Physical Interface: Change the SPI or PPI object into PPI or SPI (and vice versa) on the bimode port (140Mbit/s / STM-1 switch able).

Show supporting equipment: Navigate to the upper subrack level.

ISA Port Configuration: It allows creating the TPs for the ATM/IP/ETH connections.

N.B. This menu is available only if an ATM/IP/ETH board has been


equipped in the subrack.
2.2.9

Port menu introduction

This menu permits to set and show the transmission resources (TP) referred to the Port, by means of the
entries indicated in the following list.
The menu differs according the port type (SDH, PDH, HOA, ATM, IP and ETHERNET).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

28/396

The "Port view" is reached by means the Equipment menu and Board view to check the detailed alarms
presented, but the available menu permits to configure the port (many setting options listed in the port
menu are common with the "Transmission" view).
In these views are presented only the TP specific of the port.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

It permits navigation to the Transmission view.

TP configuration: Set parameters for the Overhead (Signal Label and Path Trace) on Synchronous
TP's.

TP Threshold Configuration: Set B2 excessive BER and Signal Degraded parameter.

TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN-PRA management.

Set Retiming: Set the retiming feature applies to the outgoing 2Mbit/s. It opens the following options:
-

Enable

Disable

AU4 Concatenation: Only for SDH ports views.

Cross Connection: Manage the connection of the paths. It opens the following options:

Cross Connection Management

Create Cross Connection

Modify Cross Connection

Monitoring Operation: Set parameters for POM, SUT . Not available for PDH port. It opens the
following menu options:
-

Creation / Deletion

Configuration

Performance: Set and show Performance Monitoring parameters and data. It opens the following
menu options:
-

Configure Monitoring

Display Current Data

Display History Data

Loopback: Enter the loopback management. Used to configure the loopback command for
commissioning or maintenance purposes:
-

Port Loopback Configuration

Loopback management

MSP: Manage the Multiplex Section Protection of the NE. Only for SDH ports view. It opens the
following menu options:
-

MSP Create

MSP Management

MSP Commands

MSP Delete

Physical Media: Manage the physical setting of the TP of the ports. Not applicable to HOA port. It
opens a menu which differs according the port type:

ED

SDH port:
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

29/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ALS Management

Show Optical Configuration

TX Quality Configuration

Single Fiber Configuration

LAPD Configuration

Ms Configuration

PDH port:
-

Line Length Configuration

HDSL Configuration

NT G703/704 Configuration

NT X21 Configuration

ETHERNET port:
-

Remote Laser Management

ALS Management

Ethernet Port Configuration

Ethernet Mapping protocol

ISA Port Configuration

Control Path Activation

Show supporting board: Navigate to the upper board level.

Navigate to Transmission view: permit to show a complete overview about the signal flow, opening
all TP's

Navigate to monitoring view: permit to show for a selected TP the related POM/SUT/TCM and TCT
object if present.

2.2.10 EPS menu introduction


This menu permits to manage the EPS protection, setting the relevant configuration, by means of the
following entries:

Management: Set EPS protections.

Configure: Set revertive / not revertive and WTR parameters.

Switch: Manage the EPS operator commands (Force, Manual, Lockout)

2.2.11 Transmission menu introduction


This menu permits to show and set the Termination Point of the equipment, thus having an overview of the
complete signal flow of the various port.
The menu permits to define all the Cross Connections and manages the transmission resources, setting the
relevant configuration.
Further access the Performance Monitoring and manage Multiplex Section Protections and Loopbacks
functions.
It permits navigation to the Port view.
The menu lists the following entries:
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

30/396

Add TP: Search and add TP to the transmission view, than presented in the screen.

Expand: Display the TP's related to a selected TP. It opens the following menu options:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Next level of lower TP

All lower TP

Next level of upper TP

All upper TP

Hide: Remove the TP from the screen of the Transmission view. It opens the following menu options:
-

Lower TP

Upper TP

Selected TP

TP configuration: Set parameters for the Signal Label and Path trace.

TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN-PRA management.
Only for PDH ports views.

TP Threshold configuration: Set B2 Ex BER and Signal Degrade threshold.

Terminate TP: Terminate the AU4-CTP paths.

Disterminate TP: Disterminate the AU4-CTP paths.

AU4 Concatenation: Only for SDH ports views.

Cross Connection: Manage the connection of the paths. It opens the following menu options:

Cross Connection Management

Create Cross Connection

Modify Cross Connection

Port Switch Over

Show Cross Connected TP's

Monitoring Operation: Set parameters for POM, SUT. It opens the following menu options:
-

Creation / deletion

Configuration

Performance: Set and show Performance Monitoring parameters and data. It opens the following
menu options:
-

Configure Monitoring

Display Current Data

Display History Data

Structure TP's: Define the structure of a selected TP (TU2, TU3, TU12, VC3/VC4, VC12)

Loopback : Enter the loopback management. Used to configure the loopback command for
commissioning or maintenance purposes: It opens the following menu options:

ED

Port Loopback Configuration

Loopback management

Physical Media: Manage the TP physical setting. It opens the following menu options:
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

31/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ALS Management

Show Optical Configuration

TX Quality Configuration

Single Fiber Configuration

Extra traffic

Regeneration Section management

Line Length Configuration

Set Domain

HDSL Configuration

NT Configuration

X21 Configuration

MSP: Manage the Multiplex Section Protection of the NE. It opens the following menu options:
-

MSP Create

MSP Management

MSP Commands

MSP Delete

NE MSP synthesis

Show supported board: Navigate to the board supporting the selected TP

Navigate to Port view: Navigate to the port supporting the selected TP

2.2.12 Synchronization menu introduction


This menu permits to set and show the Synchronization parameters and status, setting the relevant
configuration, by means of the following entries:

ED

Timing Source Configuration: Set timing source priority and quality for the selected input reference.

Protection Command: Manage commands (force, manual, lockout) for the selected timing reference.

T0 Configuration: Enable/disable SSM and WTR on the T0 synchronization source.

T4 Configuration: Enable/disable SSM, WTR and Squelch Criteria on the T4 synchronization source.

T0 TEST Configuration: Not used.

SSU Configuration: Set NE single or with SSU.

Remove Timing Reference

Change T4<->T5: Change the synchronization physical interface from 2MHz (T4) to 2Mbit/s (T5)
without traffic and vice versa.

Change 2MHx->2Mbit: Change the source of a protection unit from 2Mhz to 2Mbit and vice versa.

Set T0 Equal T4

Remove T0 Equal T4

Transmitted SSM Quality Configuration: Set SSM quality transmitted on the selected T1 SDH timing
reference.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

32/396

Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN-PRA management. Only
for PDH ports views.

Show Timing Source: Show the "port view" related to the selected timing reference.

2.2.13 External Points menu introduction


This menu permits to display and set the input/output environmental alarm (housekeeping alarm), by means
of the following entries:
Configuration: Set the input/output environmental alarm.

Display: Show the list of the input/output environmental alarm. It opens the following menu options:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

03

Show external Input Points

Show external Output Points

Show

all

external

Points

SC.3: NE MANAGEMENT
3AL 98253 ADAA

33/396

Figure 2.

ED

03

Menu options flow chart -- 1

SC.3: NE MANAGEMENT

3AL 98253 ADAA

34/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 3.

ED

03
Menu options flow chart 2

SC.3: NE MANAGEMENT

3AL 98253 ADAA

35/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 4.

ED

03

Menu options flow chart 3

SC.3: NE MANAGEMENT

3AL 98253 ADAA

36/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 5.

2.3

Menu options flow chart 4

Advices on Navigation principles

Navigation rules are the same for all the NE using the same Craft Terminal Info Model.
This general rules are described in the "Basic Craft Terminal Operator Handbook".
In this paragraphs are instead inserted menu options typical for this NE involved in Navigation and example
of Navigation.
To reach a particular view of the NE there are several ways (navigation is also possible mixing the different
ways):

ED

Double click on the selected object

Select the object and use the Open object or Open in Window option of the View pull down menu

Use the Menu option tree structure. The View pull down menu permits to show the following menus:
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

37/396

Equipment

Transmission

Synchronization

External Points

The menu structure permits to open the same window following several menu paths.
EXAMPLE: to obtain the "Create Cross Connection" window:

First navigation path:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Open View - Transmission pull down menu


Open Transmission - Cross Connection - Cross Connection Management pull down menu Select Create
option in the presented window

Second navigation path:


Open View - Equipment pull down menu
Double click on Board
Select the Board to access the Board view
Open Board - Port Access pull down menu
Open Port - Cross Connection - Create Cross Connection pull down menu

Third navigation path:


Open Configuration - Cross Connection Management pull down menu
Select Create option in the presented window

The menu structure also permits to pass from a view menu to another (i.e. from "port view" to board view" or
to "transmission view") thus facilitating the operators activity.
Views Navigation
The first level of the "Equipment view" representation will be displayed directly into the current window,
immediately after the NE login.
The Equipment view enables a fast navigation through all levels of the equipment hierarchy.
Navigation is done from higher to lower levels. The NE hierarchy is generally organized in the following way:
Subrack > board > port > TP.
Double clicking on the objects performs the navigation through different levels of the NE hierarchy:

The first level shows the subrack level of the Equipment view

By double clicking on a board body, the board level of the Equipment view can be reached.

Further, by double clicking on a port body contained in the board, the port level of the Equipment
view can be reached. The port view displays the inner TPs.

It is possible to go back to the upper level of representation by pressing the <ESC> key on the
keyboard;
It is also possible to:

ED

Go back to the previous view, by selecting the Backward option from the views menu

Go to the next view, by selecting the Forward option from the view menu.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

38/396

N.B. Selecting in the first level of the Equipment view the Show supporting equipment option from the
Equipment menu, the Rack level view (Example) is presented.
In the Rack Level view two subrack are presented:
-

At the top the 1662SMC subrack, named SR62C (Example)

At the bottom the Fans Subrack, named SRFAN (Example)

The Fans Subrack presence is managed with the Set option as for the boards of the 1662SMC
Subrack. (Example)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Further, selecting in the Rack level view the Show supporting equipment option from the Equipment
menu, the Equipment level view is presented.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

39/396

NE MANAGEMENT SUPERVISION

This chapter is dedicated to the NE states and NE access.

3.1

NE management states

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The elementary building blocks of any telecommunication network are the Network Elements (NEs).
Operating with the Craft Terminal the NE can present different management states according to the
condition of the connection (supervision, local access, connection state, etc). Also general Alarm status is
presented.
Management states are present at Network Element Synthesis view level and at USM--EML view level.
All the information referred to the management states are inserted in the Basic Craft Terminal Operators
Handbook.
Any disruption in the communication link between the CT and the NE results in an update of the
management states when the CT has detected the communication failure.

3.2

NE supervision and login

The Network Element Synthesis views enable you to get access to the current NE EML-USM view described
in this handbook.
The Network Element Synthesis views enable you to work on local or remote NE, selecting it and activating
"Supervision" and "Login", as described in the Basic Craft Terminal Operator's Handbook.
The EML-USM Main view is presented as for the following figure.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

40/396

Figure 6.

ED

03
NE EML-USM Main view

SC.3: NE MANAGEMENT

3AL 98253 ADAA

41/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

NE MANAGEMENT GENERAL CONFIGURATION

In this chapter general configuration referred to the equipment management are described (Craft Terminal
access, NE Time, Alarms configuration, etc).

4.1

Access state (allow or inhibit NE Craft access)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Craft Terminal can manage by the OS or the NE. To control the competition of the OS and the CT, a
Local Access Control (LAC) is available.
If the LAC is "granted" that means the CT is allowed to manage the NE. In the view the icon with a key
symbol has a rectangular shape.

If the LAC is "access denied" that means the OS manages the NE and the CT is not allowed to modify NE
configuration (it can only "read"). In the view the icon with a key symbol has a circular shape.

If the LAC is "requested" that means the CT has requested permission from the OS and is waiting for a
replay.
However the OS does continue to provide a certain number of services. These services includes:

Reception and processing of alarms,


Performance processing on TPs,
Switching back to the OS access state.

The access state of an NE can be modified from two types of views:


4.1.1

Switching from the OS to the Craft Terminal access state

Select the Supervision pull down menu. Then select the Requested option from the Access State
cascading menu as shown in the following figure.

Figure 7.

NE management: setting the access state.

From the confirmation dialogue box that opens you can confirm or cancel the "Craft access" operation using
the Yes or No push buttons. The request is up to the OS, which accept or refuse it.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

42/396

If the OS doesn't answer in a predefined time it is assumed that the NE is in the Craft access state and can
be managed from a Craft Terminal.
4.1.2

Switching from the Craft Terminal access state back to the OS access state

Select the Supervision pull down menu. Then select the OS... option from the Access State.
From the confirmation dialogue box that opens you can confirm or cancel the "OS access" operation.
The OS now manages the NE.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

N.B. The key symbol icon on the management states of the NE view indicates whether the OS manages by
a craft terminal or the NE.
N.B. Local Craft Terminal access is denied on recovery phase after a loss of communication of the NE.
When communication is lost with the NE, the OS automatically recovers the communication and put the state
that was set before the loss of communication (therefore the Craft Terminal access can be denied or
granted).
4.2

NE Time management

The NE local time of a selected NE can be visualized and/or re-aligned on the OS time basis.
In this view the OS indication identifies the Craft Terminal.
The status of the Network Time Protocol can be checked
Select the NE Time... option from the Configuration pull down menu.

Figure 8.

Consulting and/or setting the local NE time

The following dialogue box is opened from which you can get and/or set the local NE time and check the
NTP Status.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

43/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 9.

NE Time dialogue box

The following fields are available:

NTP Status section (read only) with the following parameters:


NTP protocol
It can be enabled (in the NTP Server Configuration) or disabled or empty (grey).
NTP Main and NTP Spare
It displays the status of the Main and Spare NTP: reachable or unreachable.

Time section with the following data:


NE Time and OS Time
It displays (read only) the time of the Network Element and of the OS (Craft Terminal).
Set NE Time With OS Time
It permits to align the NE time with the time of the Craft Terminal.

Two different operative conditions can be defined:

ED

NTP protocol enabled

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

44/396

In this case, NTP Main and NTP Spare will be reachable or unreachable. When both are reachable
the NE uses the Main.
The Set NE Time With OS Time message is not operative and the user cannot set manually the NE
Time.

NTP protocol disabled


In this case, the NTP Main and NTP Spare are empty (grey); the Set NE Time With OS Time
message is operative and the user can set manually the NE Time (i.e. change the NE time with the
Time of the Craft Terminal).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

If you do not want to set the NE local time, click on the Close push button to close the dialogue box.
To re-align the NE time on the OS time basis click in the Set NE Time With OS Time radio button and either
click on the Apply push button to validate or on the Close push button to cancel and close the dialogue box.
The OS time comes from the PC date configuration that corresponds to the legal GMT time.
N.B. When the NTP is not present, the OS system re-aligns the time of all supervised NEs periodically and
automatically with a configured periodicity. This periodicity is common for all the NEs.
If you set the NE time, you will force the change, with an immediate effect on the NE. However it will not
have any effect on the periodic and automatic mechanism.

4.3

Alarm Configuration

The operations described in this chapter, mainly related to alarm setting, are:

Alarm Severity Assignment Profile management,

Allow/Inhibit alarm notification,

Alarm re-synchronization

4.3.1

Procedure to modify an ASAP

a)

Select the TP (or board/port/etc) whose ASAP is to be changed

b)

From the menu click on Configuration -> alarms Severities.

c)

Select one of the user profile (#10001 or #10002) and click on Modify

d)

Click on the Probable Cause Families associated to the alarm

e)

Select the relevant alarm in the list of Probable Cause Name

f)

In the Service affecting/non-affecting fields select the needed severity (critical/major/minor)

g)

Click on OK

h)

Click on Close

i)

Select the relevant TP and then Configuration -> Set Alarms Severities

j)

In the box that appears select the just modified ASAP (eventually check it by means of Detail)

k)

Click on OK

4.3.2

Alarm Severity Assignment Profile Management (ASAP)

Managed entities yield alarms when they malfunction. This section deals with the configuration of ASAPs. An
ASAP is a list of Alarm probable causes to which Severities Profiles are assigned, predefined or settable by
the operator.
Three important notions are:

ED

The Probable Cause of the alarm,


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

45/396

The Severity of the alarm.

The Alarm Type (communication alarm, equipment alarm).

4.3.2.1 Alarm Severities


This option permits to configure and display the ASAP.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Alarm Severities... option from the Configuration pull down menu.

Figure 10.

Configuring Alarm Severity Assignment Profile

The ASAP Management dialogue box is displayed.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

46/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 11.

ASAPs Management dialogue box.

The default presented profiles is:

Profile No alarms. Whit this profiles all the alarms are enabled (only Software Download Failure
is not alarmed). This ASAP enables the emission of all alarms.

Profile No Remote Alarms shows the alarm criterion configuration defined for "path alarms" (only
AIS and RDI and Software Download Failure are not alarmed). This ASAP enables the emission of
all:

ED

Communication Alarms (i.e. the AIS & RDI alarms are not alarmed)

Equipment alarms

Environmental

Error Processing (i.e. Software Download Failure is not alarmed)

Profile Primary alarms with this profile the AIS, Battery Degraded, Software Download Failure,
SSF and RDI alarms are not alarmed. This ASAP enables the emission of all:
-

Communication Alarms (i.e. the AIS, SSF & RDI alarms are not alarmed)

Equipment alarms

Environmental

Error Processing (i.e. Software Download Failure is not alarmed)

Profile All Alarms (i.e. all alarms disabled). This ASAP inhibits the emission of any potential
alarm.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

47/396

The user can set profile 10001. Each single alarm can be classified with a criterion selected by the
operator. A default standard configuration is set. (Battery Degraded, Battery Failure, Communication
Subsystem Failure, Path Trace Mismatch are not alarmed).
NOTE: if this profile is not already present in the list, it is necessary to create it, selecting
one existing profile and then clicking on the Clone button.

You can select an ASAP.


For ASAP "10001" it is then possible to choose Detail, Modify, Clone or Delete buttons.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

For ASAP No Alarms, Primary alarms. No Remote Alarms and All Alarms it is only possible to choose
Detail, or Clone buttons.
Clone selection can be used to create new ASAP.
Click on Detail, Modify, or Clone button, the ASAP edition dialogue box is displayed.

Figure 12.

ASAP Edition dialogue box.

The alarm severity assignment profile dialogue box displays a list of probable causes and a list of alarm
severity.
The Probable cause family checks buttons allows filtering the probable causes that will appear in the
Probable cause name list. NOTE: it is necessary to choose one or more of these filters to have the list.
To find a particular probable cause, enter its name in the Search entry box at the bottom.
ASAPs are already defined in the system with default values for the assigned severities.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

48/396

You can modify the severity associated with each probable cause. To do this, select the probable cause
whose severity level you wish to modify.
Then click on the option button: Service Affecting (not protected probable cause), and then Non Service
Affecting (protected probable cause) and then Service Independent (don't used, it is not operative). For each
the severity can be chosen from "Critical", "Major", "Minor", "Warning", "Non-alarmed" or "Not used". A "Nonalarm" probable cause corresponds to no alarm emitted for this probable cause.
When selecting Details the assigned severity are only shown and it isn't possible to modify.
When you have finished configuring ASAP, press the OK button to confirm the settings and close the
dialogue box or the Cancel push button to cancel the new settings and close the dialogue box.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

When Clone an ASAP the created one is identified with next number (10002,).
The max number of ASAP is six.
N.B. The number of severities and the number of probable causes is fixed. The ASAP function only enables
the modification of the severities assigned to the probable causes, it does not allow the addition, removal or
modification of these severities and causes.
N.B. To take into account a profile modification, it is mandatory to perform a re-synchronization of the alarms.
During this re-synchronization, the severity of each alarm is updated. Otherwise, the severities are updated
only when the NE emits the modified or new alarms.
4.3.2.2 Set Alarm Severities
To assign an alarm severity to a TP or equipment, select the TP or equipment in the related view and then
select the Set Alarm Severities... option from the Configuration pull down menu.
The Set ASAP dialog opens.

Figure 13.

ED

03

Set ASAP dialogue box.

SC.3: NE MANAGEMENT
3AL 98253 ADAA

49/396

Within the "Apply to" section on the right side, the user specifies the objects (TP or equipment) the ASAP
selected in the List of ASAPs (new ASAP) should be applied to:
Choose Scope

Selected object only


The new ASAP is only applied to the object currently selected in the view.
This is the default if an object is selected in the view.

Network element

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The new ASAP is applied to all objects of the NE matching criteria specified in "Choose
Classes" and "Choose current ASAP".
Since this application process takes some time, its progress is shown in the section "Execution
Monitoring".
This is the default if no object is selected in the view.

Selected object and subordinates


The new ASAP is applied to the selected object and those of this subordinates matching the
criteria specified in "Choose Classes" and "Choose current ASAP".
Since this application process takes some time, its progress is shown in the Section "Execution
Monitoring".
N.B. Due to system architecture, AU-4CTPs are no subordinates of MSTTPs. Therefore, if
the AU-4 CTP should be included as subordinate, select the related OSTTP (OpS) or
ESTTP (EIS) as main object.

Choose Class (es)


Enabled if one the scopes "Network Element" or "Selected object and subordinates" is selected.

All classes (es)

Specific class (es)


Select one or more object classes the new ASAP shall be applied to.

Choose current ASAP


The new ASAP is only applied to objects, which are currently assigned to the ASAP.
Execution Monitoring
Continuously shows the number of modified objects during the ASAP application process if one of the
scopes "Network element" or "Selected object and subordinates" is chosen.
Press Ok to confirm the ASAP assignment and close the dialog. Press Close to close the dialog and discard
any changes.
4.3.3

Set SdhNE Alarms Severities

Selecting the Set SdhNE Alarms Severities option from the Configuration pull down menu only the alarms
at Equipment level (FF, BKF, SHD and ABF) are managed.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

50/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 14.

Set SdhNE Alarms Severities

If an object was selected in a view before opening this dialog, its ASAP is highlighted in the list. Using the
Detail button or double-clicking on a list item opens the ASAP Edition dialog which displays detailed
information on this ASAP.
Press Ok to confirm the ASAP assignment and close the dialog. Press Close the dialog and discard any
changes.
4.3.4

Allow/Inhibit Alarms Notifications

The system provides the possibility to allow/inhibit the spontaneous incoming alarm notifications.
a) To inhibit alarm notification, select the Supervision pull down menu. You can then select the Inhibit
Notifs option from the Alarms pull down menu as shown in the following figure.

Figure 15.

Inhibit alarm notification

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Ok or
Cancel push buttons respectively.
To inform the operator that alarms have been inhibited, the labels of the alarm panel are grey out.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

51/396

N.B. Inhibiting the alarms notification means that they are not forwarded to the CT but alarms are still
generated by the NE.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

b) To allow alarm notification


Select the Supervision pull down menu. You can then select the Allow Notifs option from the Alarms pull
down menu as shown in the following figure.

Figure 16.

Allow alarm notifications

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Ok or
Cancel push buttons respectively.
4.3.5

Alarms resynchronization

The system provides the possibility to recover alarms present on the NE and to update the current problem
list of the NE. After this operation CT and NE current alarms are consistent.
To re--synchronize the alarms, select the Supervision pull down menu. You can then select the
Resynchronize option from the Alarms pull down menu as shown in the following figure.

Figure 17.

Alarm re--synchronization

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Ok or
Cancel push buttons respectively.
N.B. This functionality has to be used only if there is any perturbation. Never use this operation during a
correct behavior.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

52/396

Alarms persistency Configuration

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

4.3.6

Figure 18.

Alarms persistency Configuration Menu option

Figure 19.

ED

03

Alarm persistency Time Configuration

SC.3: NE MANAGEMENT
3AL 98253 ADAA

53/396

4.4

Restart NE

The restart operation is a software reset and can be executed in normal traffic conditions.
The restart operation in any case activates the Commit (active) version.
Select the Restart NE option from the Supervision cascading menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following dialogue box is opened.

Figure 20.

Restart NE confirmation

Click on the Cancel push button to abort the restart NE.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

54/396

SECURITY MANAGEMENT

In this chapter are inserted setting options referred to the Security management:

5.1

Set Manager list

This option is referred to the Security management and allows the user to set the Manager list and the
Access Control Domain of the NE.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Set Manager list option from the Supervision pull down menu.
The dialog-box contains the following fields:

Manager list: each connected manager to the NE is highlighted in the list. The user can set a
manager clicking on the denomination.
Several managers can be enabled contemporaneously, having in charge the NE.
The Manager List contains the list of managers (i.e. RM, SY, NPOS, EML) that work on the NE. The
EML-USM administrator (SH or Craft Terminal) should set the Manager List only to remove a
manager in case of emergency (i.e. the Manager misses the NE connection).

NE Domain field allow selecting the domain among that displayed in the list, assigning it to the NE.
The different domains could be assigned to different operators.

OK button is used to validate the selection.


Cancel button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

Figure 21.

5.2

Set Manager list

Set ACD level

This option allows the user to select the level of the Access Control Domain.
The ACD manage the concurrence of access among several different managers (i.e. RM and EML).
This only acts on the functions that can be used by different manager.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

55/396

Select the Set ACD level option from the Configuration pull down menu.
The dialog-box contains the following fields:

Current ACD level


Show the Access Control Domain level currently set.

The Access Control Domain check level

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Permit to set one of two level checks. By the way, this is an operation that should be performed only
during the EML-USM installation phase:

NE level, the ACD is performed on all the NEs

No Check, the ACD is not managed

The default value is NE level. If it is changed, it is necessary to restart the EML-USM.


OK button is used to validate the selection.
Close button close the dialog without changes of the data.

Figure 22.

ED

03

Set ACD level

SC.3: NE MANAGEMENT
3AL 98253 ADAA

56/396

EXTERNAL INPUT AND OUTPUT POINTS MANAGEMENT

This chapter describes how to display and set the input/output environmental alarm (housekeeping alarm),
An external input point is an environmental alarm (also called housekeeping alarm). It corresponds to an
external event, which is monitored by the NE. Number of relays on the NE is dedicated to check modification
of the environment as for example a fire, a flood...
An external output point is used to manage a NE contact (i.e. relay) connected to detector. An external
output point is independent from external input point.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

The operations that can be undertaken in this section are:


-- Displaying external points,
-- Expanding or reducing external points list,
-- Configuring input and output external points.

6.1

Displaying external points

Select the External Points option from the Views pull down menu.

Figure 23.

Opening the external points view

After selecting this menu option the external points view is displayed into the current window instead of the
current view.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

57/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 24.

External points view

The external points view displays a list of all input and output points.
The following information is given for each external point:

The external point type: Input or Output.

The user label: a user-friendly label associated to the configurable external point (see further the
paragraph External points configuration).

The external state: represents the alarm state. "On" when the alarm is raised, else "Off". If the
external point is active (On), a little flag is represented near the status of the concerned point.

Only for the Output external point there is the following information:

ED

The Output criteria: if configured, display the alarm event and the board effected associated to the
Output point (see further the paragraph External points configuration)

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

58/396

6.1.1

Expanding or reducing external points list

The external points view displays a complete list of the external points but it can also be restricted to the
input or to the output points.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To see either the input points, the output points or all the external points, select the appropriate option from
the External Points pull down menu as shown in the following figure.

Figure 25.

6.2

Expanding or reducing the external points list.

External points configuration

The configuration operations available on external points are:

"User labels" configuration

"External state". Can be set for output points (ON or OFF)

"Output criteria" associated to the External output point

To configure an external point, click on the concerned row. And then select the Configuration option from the
External Points pull down menu as shown in the following figure.

Figure 26.

Configuring external points.

The following dialogue box is then opened, displaying information about the selected external point (Input or
Output).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

59/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 27.

Figure 28.

ED

03

External input point configuration dialogue box

External output point configuration dialogue box (MANUAL)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

60/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 29.

External output point configuration dialogue box (FLEXIBLE)

Opening the dialog the current state of the selected External Point is shown.
1) External Input Point Configuration

User Label: this field can be filled by the user with a Label that indicate the associated event that
must be taken under check (for example presences of water of fire in the room where the Equipment
is placed)

External State: this field is set to off and can't be changed by the operator

Probable Cause: the field is set to housekeeping and can't be changed by the operator

2) External Output Point Configuration

User Label: this field can be filled by the user with a Label that indicate the alarm detected or the
action that must be executed if a specific event occur (for example a "Pump" activation when water
is present in the room where the equipment is placed.

External State: can be set to "on" (alarm) or "off" (non alarm) only if "Manual" option has been
selected in the "Output Criteria" field.

Output Criteria can be configured as:

Manual (forced). The output contact is set in a fixed way, not depending on a particular event.

For example the output contact could be used to "Manually" activate a pump drain water from the
room where the equipment is placed; in this case is also necessary to set the option "On" in the field
"External State".

Flexible. It is possible to define from CT the couple event/CPO#, where the event is chosen between
a set of Output Criteria (LOS, RDI and LOF) and specifies the STM-N interface which the Output
Criteria refers to by clicking on Choose button; subsequently the TP search dialog box will be
opened.

When the configuration of the external point is completed, click on the OK push button to validate the choice
and close the dialogue box. The Cancel push button cancels the configuration and closes the dialogue box.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

61/396

DIAGNOSIS MANAGEMENT

Alarms are always present on the operator's workspace. The different types of alarms, their number and their
severity level, are represented in all Equipment views (NE views, Board views and Port views). An icon
representation is used, which change color when the relevant alarm is active. Thus, at all times, you know
the number of alarms and their severity relating to the equipment.
Access to the Alarm Surveillance to show the alarm condition is detailed in the following paragraph.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Than is presented the abnormal condition list (as result of operator's command such us loop, laser forced on
etc.).
At the end the Event log access is introduced.
Information about the significance of equipment alarms and status is given in the Maintenance
section.

7.1

Alarms surveillance

In this chapter is described the access to the Alarm Surveillance information of the NE.
It is possible to show all the Alarms or filter the alarms report.
Select the Diagnosis pull down menu. You can then select the following option from the Alarms pull down
menu:

NE Alarms: all the NE alarms are listed in the Alarm Surveillance report which is activated

Object Alarms: only the alarms of the selected object are listed in the Alarm Surveillance Report

Subtrees Alarm: only the alarms of the selected object and of the relevant subtrees are listed in the
Alarm Surveillance report

Equipment Alarms: only the alarms of the equipment management are listed in the Alarm
Surveillance report

Transmission Alarms: only the alarms of the transmission management are listed in the Alarm
Surveillance report

External Points Alarms: only the alarms of the input external point management are listed in the
Alarm Surveillance report

Figure 30.

Alarm Surveillance Menu

Selecting any of the previously seen options, the Alarm surveillance report is displayed as for the example of
the following figure.
This view shows first a synthesis of the NE alarms (Counter Summary) with the sum of all alarms, then a
detailed list of alarms of the selected filter (Alarms Sublist).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

62/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 31.

Alarm Surveillance

Detailed information for each alarm is supplied.


For example the board in which the alarm is detected, the status of the alarm, the alarm type, the probable
cause.
The information supplied helps the operator, typically during troubleshooting operation, presented in next
section. (Maintenance section, where more details about alarms is given).
Detailed description is given in the AS Operator's Handbook.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

63/396

7.2

Abnormal Condition List

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The abnormal condition provides the synthesis of NE "not normal conditions" listing the events that
contribute to abnormal condition. Select Diagnosis->Abnormal Condition List.

Figure 32.

Figure 33.

Abnormal condition menu option

Example of abnormal condition list

The abnormal conditions are the following:

Loopback

ALS is disable and the laser is forced on or off

Protection units (in case of EPS, SNCP and MSP if supported) are in lockout or in forced status

Board (or sub-board) is placed in a not configured slot

Select an abnormal condition and click on OK to open the relative dialog window. Figure below is opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

64/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 34.

Example of loopback dialog window management

The other abnormal condition types will open the corresponding management window or will open the
window to navigate towards the management window.

7.3

Internal Link Monitor

This function improves, at the user interface level, the diagnostic associated to the hardware failure.
The presence of a failure on RX or TX side for the signal incoming/outgoing from/to the active MATRIX is
detected; Internal Link Monitor displays a detailed localization of the link failure: a graphical representation of
all NGI link status, for the active and stand-by MATRIX is shown.
Select the Internal Link Monitor option of the Diagnosis menu.
As shown in Figure below. The first page displays the link status for the main MATRIX, the second one
concern the spare MATRIX.
In detail, each page contains the following functional blocks and graphical objects:

ED

The tab of the page displays the user label of the MATRIX board;

The left side of the page displays the block representing the MATRIX board;

The right side of the page displays the list of blocks representing the equipped boards; each block
displays a string contained the user label of the associated board;

Two arrows are displayed between the MATRIX block and each board block; the two arrows
represent the link status in RX and TX side:
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

65/396

A red arrow indicates a "link failure"

A green arrow indicates a "working link"

The Refresh button allows performing an explicit refresh of all the displayed information.

In order to indicate all the possible roots of the "link failure", all boards that detect the link failure are
represented by a red block in the page of the MATRIX main:
a port" board in represented by a red block if a link problem is detected in the NGI Rx from the
active MATRIX.

A red block represents the MATRIX if a link problem is detected in one of the NGI Tx from one of the
possible "port" board.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 35.

7.4

Internal Link Monitor

Log Browsing

From the Network Element context views, perform the following operations to have access to the Event Log
file:
-

In the Diagnosis pull-down menu, select the Log Browsing option.

Figure 36.
ED

03

Log Browsing option in Network Element context view

SC.3: NE MANAGEMENT
3AL 98253 ADAA

66/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Proposed option:

Select the Alarm Log option (Log Id # 1) to access the Event Log file.

The Configuration and Log Browsing ELM Windows open, permitting to analyze all alarms stored in
the NE.

Refer to the "ELB Operator's Handbook"

Select the Event Log option (Log Id # 2) to access the Event Log file.

The Configuration and Log Browsing ELM Windows open, permitting to analyze all events stored in
the NE.

Refer to the "ELB Operator's Handbook"

Software Trace Log option is reserved to Alcatel personnel only.

7.5

Remote Inventory

This paragraph describes the access to the remote inventory of this NE.
In the Remote Inventory are stored information of identification, construction data etc.
The options used are:

Upload Remote Inventory: store the Remote Inventory data in the Craft Terminal.

View Remote Inventory: display the remote inventory data, previously stored in the Craft Terminal
by means the "upload remote inventory" performed in the "Supervision" menu.

Remote Inventory option of the Equipment.


7.5.1

Upload remote Inventory

This command stores the Remote Inventory data in the Craft Terminal.
Select the Upload Remote Inventory option of the Supervision pull down menu.
A confirmation dialog box is opened.

Figure 37.

Remote Inventory confirmation request

Clicking on OK after a while an information dialog box is presented.

Figure 38.

ED

03

Remote Inventory completed

SC.3: NE MANAGEMENT
3AL 98253 ADAA

67/396

7.5.2

View Remote Inventory

This command displays the remote inventory previously stored in the Craft Terminal by means the Upload
remote inventory.
Select the View Remote Inventory option of the Diagnosis pull down menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Remote inventory data appears.

Figure 39.

View Remote Inventory

Data is displayed in specific fields:

Company

It indicates the Company's (Alcatel's branch) which designs the unit.


Refer to Alcatel for the abbreviation's meaning (four characters).

Unit Type

It indicates the units' acronym

Unit Part Number

It indicates Alcatel or Factory product's Part No. The number indicated is that printed on the labels or on the
units' front cover plate.

Software Part Number

It indicates the id. of the unit's resident software

CLEI Code

It indicates the CLEI code according to Belle core specs. TR-ISD-325

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

68/396

Manufacturing plant

It indicates the Company's manufacturing plant id. Within the company, producing the unit.
Refer to Alcatel for the abbreviation's meaning (four characters).

Serial Number

It indicates the product's serial number as specified by the NR 130 Norm.

Date identifier

It indicates the meaning of the date that follows.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

It is a two-digit code supplying the following information:


00 date of construction at the time of final testing
01 production order data
02 construction date of the unit lot
03 date products has been forwarded to customer
04 customer order date

Date (YYMMDD)

The identification of the date depends on the indications stated in the previous field. When only the year is
displayed, the format must be "YY- - - - "

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

69/396

COMMUNICATION AND ROUTING MANAGEMENT

8.1

Overview on Communication and Routing Domain

The purpose of the communication and routing domain is to define configuration parameters concerning the
communication protocols for the local NE, the OS and each other related NE in order to provide a global
communication capabilities inside the network.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

8.1.1

OSI Protocol on QB3/Qecc

A brief description of basic concepts and terms involved in the communication and routing domain follows.
During the TMN design process, a network is partitioned into domains; each domain can consist of a
collection of two types of nodes:

Nodes supporting a link state routing protocol IS-IS; these nodes will be called adaptive routers;
IS-IS protocol floods the network with link state information in order to build a complete consistent
picture of the network topology. Use of IS-IS routing protocol in a TMN facilitates installation and
operation due to the "self learning" capabilities of these protocols and automatic network
reconfiguration in case of failure; moreover the use of these standardized routing protocols
guarantees interoperability in a MultiFinder environment.

Nodes not supporting these protocols; these nodes will be called static routers;

Networks partitions consisting of the former type of node will be called adaptive routing domains; networks
partitions consisting of the later type of node will be called static routing domains.
Moreover, a node which have to take routing decisions must became Intermediate Systems, all others can
be made End Systems
For the description of the following paragraphs use is made of Figure below. It is not a network-planning
example; it is only used to describe L1, L2, RAP and MESA.
8.1.1.1

Partitioning into Routing Sub domains

In order to reduce the overhead associated with distributed adaptive routing, it may be useful to divide a
adaptive routing domain into smaller routing sub domains, called areas or level 1 sub domain. A level 1 sub
domain should fulfill the following requirements:

A level 1 sub domain should form a connected sub network; this sub network should have only a few
links to the outside world, compared with the number of internal links;

Each node must belong to exactly one level 1 sub domain;

Each node which is connected to a foreign level 1 sub domain must become a level 2 intermediate
system; level 1 intermediate systems know how to communicate only with IS in the same area;
obviously, there must be at least one level 2 intermediate system per level 1 sub domain;

Level 2 intermediate systems must form a connected network, because level 1 path cannot be
utilized for level 2 communications. This network will be called level 2 backbones.

In the simplest case, all nodes within a level 1 sub domain share the same area address.
In general it is allowed to have multiple synonymous area addresses within a level 1 sub domain even if the
usage of this features should be checked with Alcatel engineers.
The synonymous list is used to ease partitioning in the future. There is a basic rule, which must be followed
by two neighboring level 1 intermediate systems within a sub domain: there must be at least one area
address in common between their two synonymous list, otherwise they are not able to communicate with
each other.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

70/396

8.1.2

Partitioning into separate Routing Domains

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In certain situations it may be necessary to partition a given network into separate routing domains, where no
routing information is exchanged between these domains. The major benefits of this partitioning are
reduction of memory, processing and traffic overhead, because there is no exchange of routing information
between the domains. Communication between separate routing domains must be achieved through the use
of Reachable Address Prefixes (RAP).
A Reachable Address Prefixes represents static routing information. It can only be associated with a link of
a level 2 intermediate systems, whereby this link crosses routing domain boundaries. A Reachable Address
Prefixes is handled in the same way as information about a foreign level 1 sub domain within the own
domain. The Reachable Address Prefixes indicates that any packet whose destination network address
NSAP matches the prefix may be forwarded via the link with witch the prefix is associated.
For example, consider network, which is split into two separate routing domains:

Routing domain A resides in a level 1 sub domain with area address "a"

Routing domain B resides in a level 1 sub domain with area address "b"

In order to enable the communication, the Reachable Address Prefixes in routing domain A must contain the
area address "b" and the Reachable Address Prefixes in routing domain B must contain the area address "a".
On the other hand, within a given level 1 sub domain, there can be some NEs not supporting IS-IS nor ES-IS
protocol (static routing). In such condition, the communication can be achieved through the use of Manual
End System Adjacencies (MESA).
A prerequisite for the use of manual end system adjacencies is that the area addresses of the connected
nodes must be the same; as a consequence the nodes must belong to the same level 1 sub domain. Within
a pure Alcatel network there is no need to use any kind of static routing. Therefore normally RAP and MESA
shall never be used.

Figure 40.

ED

03

Routing sub domain organization example

SC.3: NE MANAGEMENT
3AL 98253 ADAA

71/396

8.1.3

IP over OSI tunneling for ATM/IP

This feature is applicable to NEs equipped with ATM/IP boards.


It permits to create a tunnel over OSI systems, to communicate IP management messages through an OSI
network; it encapsulates the SNMP messages of the TCP/IP protocol stack over the OSI stack, using CLNP,
LAPD, ECC protocols, and an OSI address. In this way the message reaches its final destination
8.1.4

OSI over IP tunneling on QB3

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This feature allows the Element Manager to reach the GNEs (and all the relevant NEs behind them) by using
IP networking.
This would permit to use an external DCN based on IP only. Hence, no OSI networking would be required on
the external DCN.
OSI over IP technique is used to meet the target. OSI packets leaving the SH are encapsulated into IP
packets within the SH system itself. Hence, packets leaving the SH are IP packets, containing the original
OSI packet.
Once the packet gets the NE through a pure IP network, the GNE has to strip off the IP encapsulation,
extracting the OSI packet, and to route the OSI packet as it does today using a pure OSI networking.
Hence, the internal networking of the SDH network (DCCs) is still based on OSI. No IP packets shall flow
inside DCCs, because the GNE receives the IP packet containing the OSI packet, deletes the IP header, and
forwards only the OSI packet on DCCs.
The default OSI lower layers networking can be replaced by IP routing capability at the bottom of the
QB3/QECC communication protocol suite; the choice is software switchable at NE level. The implementation
adopts the RFC1006 standard to put the OSI upper layers on top of IP networking.
The application goal is to offer the TCP/IP transport (i.e. Internet compatibility) in alternative to the full
ISO/OSI communication protocols, in the complete DCN network or at least in a consistent portion of it.
Figure below depicts the protocol architecture.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

72/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 41.

8.2

OSI over IP tunneling on QB3

Communication and routing views

To access select Comm/Routing option from the Configuration pull down menu as shown in the following
figure.
The Communication and Routing Views allows to perform the following operations:

ED

Local Configuration: definition of the local NE addresses

OS Configuration: addressing of the main and spare OSs connected to the local NE

NTP Server Configuration: addressing of the main and spare NTP servers connected to the local NE

Interface Configuration Subdivided in:

LAPD Configuration: definition of the LAPD port parameters for each LAPD channel on the local NE

Ethernet Configuration: definition of configuration parameters needed to manage a local NE which


provides a LAN Ethernet interface

OSI Routing Configuration Subdivided in:

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

73/396

RAP Configuration: configuration of parameters necessary to the addressing of NE connected


by Reachable Address Prefixes in a domain different from the one of the local NE. This
information is stored in RAP table.
MESA Configuration: configuration of parameters necessary to the addressing of non IS-IS NE
in the same domain as the one of local NE. This information are stored in MESA table.

IP Configuration Subdivided in:


IP Static Routing Configuration: definition of Host/Network destination address for IP static
routing

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

OSPF area Configuration: definition of Open Shortest Path First address


IP Address Config. Of Point-to Point Interfaces: definition of the Equipment Controller IP address
ISA board IP address: definition of the ISA board IP address

Tunneling Configuration Subdivided in:


OSI over IP: definition of destination IP address for IP for OSI over tunneling
IP over OSI: definition of destination NSAP address and type of IP routing for IP over OSI
tunneling

All the previously cited operation can be entered choosing the relevant option of the menu, as shown in the
figure.
The options are described in next paragraphs.

Figure 42.

ED

03

Comm/Routing options

SC.3: NE MANAGEMENT
3AL 98253 ADAA

74/396

8.3

Local Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascading
menu the Local Configuration option.
The dialog-box opens and allows configuring the local address of the NE.
The following fields are present:

a Local Address section contains the following graphical object:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

a Presentation Selector (P.Sel) identifies a presentation entity at the location identified by the
NSAP Address. The presented value must not be modified.
a Section Selector (S. Selector) identifies a section entity at the location identified by the NSAP
Address. The presented value must not be modified.
a Transport Selector (T. Sel) identifies a transport entity at the location identified by the NSAP
Address. The presented value must not be modified.
a Network Service Access Point (NSAP) Address identifies a location in the network. The first
field of the NSAP address, AFI, determines the NSAP format. The AFI filed is 2 characters long
(2 hexadecimal digits) and, depending on the its value, the length of NSAP address is variable
from 16 characters to 40 characters:
o

The value of AFI 49 identifies the local format of variable length (from 16 characters
to 40 characters).

The value of AFI 39 identifies the ISO-DCC format of 40 characters long.

The value of AFI 47 identifies the GOSIP-V2 format of 40 characters long.

In all cases the last two fields of the NSAP address are:
o

System Id: uniquely identifies a NE in an area and is 12 characters long. It might be


the equipment MAC Ethernet address; level 2, inserted in the NE or the operator
might select it.

Network Selector: provides the distinction among users of the network service and is
2 characters long (value is "1d").

In the view, the NSAP is managed as simple strings of characters without any pre-formatting
because of the variable format:
o

a first string of two characters that identifies the AFI field

a second string of variable length that identifies the remaining NSAP address

Synonymous Area Addresses section allows having multiple synonymous area addresses within a
level 1 sub domain. The compilation of the two network addresses is optional and if they are inserted,
the last two fields, System Id and Network Selector, of the mandatory address and of the
synonymous addresses must be the same.

System Type section determines whether the local NE acts as a "intermediate system level 1" or as
a "intermediate system level 2" or as a "End System". Note that a level 2 intermediate systems
performs functions of a level 1 too. End System is not operative.

Ok button is used to perform a configuration change of the data contained in the dialog-box and closes it; the
dialog is visible until the end of the operations and a wait cursor is displayed.
Cancel button close the dialog without changes of the data.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

75/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Help button provides some useful information about the dialog.

Figure 43.

8.4

Local Configuration

OS Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascading
menu the OS Configuration option.
The dialog-box opens and allows configuring the addresses of the Main and Spare OSs connected to the
local NE.
The following fields are present:

Main OS Address section contains the same graphical object of the Local Address Section in the
Local Configuration dialog-box.

Spare OS Address section contains the same graphical object of the Local Address Section in the
Local Configuration dialog-box.

Ok button is used to perform a configuration change of the data contained in the dialog-box and closes it; the
dialog is visible until the end of the operations and a wait cursor is displayed.
Cancel button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

76/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 44.

8.5

OS Configuration

NTP Server Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascading
menu the NTP Server Configuration option.
The dialog-box opens and allows configuring the addresses of the Main and Spare NTP (Network Protocol
synchronization Time) Servers connected to the local NE, used for time distribution in the network.
The following fields are present:

Enabling NTP Protocol section allows enabling or disabling the NTP Protocol.

Main NTP Server Address section contains the same graphical object of the Local Address Section
in the Local Configuration dialog-box.

Spare NTP Server Address section contains the same graphical object of the Local Address Section
in the Local Configuration dialog-box.

If the NTP server is coincident with the OS (same hardware), the same NSAP address of the OS must be
assigned.
Ok button is used to perform a configuration change of the data contained in the dialog-box and closes it; the
dialog is visible until the end of the operations and a wait cursor is displayed.
Cancel button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

77/396

Figure 45.

ED

03
NTP Server Configuration

SC.3: NE MANAGEMENT

3AL 98253 ADAA

78/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

8.6

LAPD Configuration

Select the Configuration pull down menu. Select the Comm/Routing-> Interface Configuration option
and then from the cascading menu the LAPD Configuration option.
The "LAPD Configuration" dialog opens.
It contains the following functional block and graphical objects:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

A section named LAPD Interfaces List that allows the user:

To display the list of configured LAPD Interfaces using a graphical table;

To change the role of the LAPD Interface selected in the LAPD Interface List;

To delete the LAPD Interface selected in the LAPD Interface List;

To create a new LAPD Interface

This section contains the following graphical objects:

The number of LAPD interface displayed in the LAPD Interface List;

The LAPD Interface List that lists all the configured LAPD Interfaces; for each LAPD Interfaces, the
table displays:

The user label of the TTP containing the configured LAPD Interface (MS/RS/E1A TTP);

The LAPD role that contains one of the following value:

User

Network

Delete button that allows to delete the LAPD Interface selected in the LAPD table;

Change Role button that allows too change the role (User or Network) of the LAPD Interface
selected in the table;

Create button that allows to create a new LAPD Interface; this button starts a new dialog. Named
Create LAPD Interface; it is disabled when the maximum number of LAPD Interface has been
configured.

This Create LAPD Interface dialog contains the following functional blocks and graphical objects:

A Choose button that allows the operator to select the superior TTP of the LAPD Interface to
be created; this button starts the TP Search dialog; the TP Search dialog will be configured in order
to display in the right tree only the allowed TTP of the LAPD Interface;

A section LAPD Role that allows configuring the role (User or Network) of the LAPD Interface to be
created.

This connection is a must to establish connection between two NE's: if one is configured with User
role, the other one connected must be configured with Network role.

- a section named Search Criteria that allows the user to display only the LAPD's of the selected type in
the LAPD Table; the section contains the following graphical objects:

ED

The field Interface Type that allows to select the type of the LAPD's to be displayed in the LAPD
Table; the field will manage both ADM and WDM DCC type; the value "Ignore" will allow to display
all the LAPD types;

The Search button starts the search of the selected LAPD type; this buttons can be used to refresh
the LAPD table too.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

79/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The LAPD Interface List will be updated on reception of the Delete/Create/Change DCC CTP notification. If
no LAPD Interface is configured in the equipment, the message "No LAPD Interface" will be displayed near
LAPD Interface counter (that it is at zero)

Figure 46.

Creation LAPD Interface

\
Figure 47.
ED

03

TP search dialog

SC.3: NE MANAGEMENT
3AL 98253 ADAA

80/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 48.

LAPD Configuration dialog

Close button close the dialog without changes of the data.

Figure 49.

ED

03

Confirmation to change LAPD Role

SC.3: NE MANAGEMENT
3AL 98253 ADAA

81/396

8.7

Ethernet Configuration

Select the Configuration pull down menu. Select the Comm/Routing-> Interfaces Configuration option
and then from the cascading menu the Ethernet Configuration option.
The dialog-box opens (figure below) and allows defining the parameters needed to manage a NE, which
provide a LAN Ethernet interface.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following fields and data are present:

Ethernet Interface field allows defining or removing a Local Area Network Port for the access to the
Data Communication Network.

MAC Address section allows displaying the address of the Network Element in the Ethernet LAN; it
is a read-only field.

OSI Section:

L2 only Parameter field indicates if the port shall be used for level 2 traffic only, thus
avoiding transmitting L1 packets. Note that the flag shall be set to No if some other
nodes (NEs or OSs) of the same area of the relevant NE are connected to the
Ethernet.

L1 Default Metric is a not modifiable field, Priority field can be set (default value for
Ethernet is 64)

L2 Default Metric is a not modifiable field, Priority field can be set (default value for
Ethernet is 64)

IP Section allows to define the node IP Address, IP Mask and the Routing IP Protocol used; If
OSPF or Both options of Routing IP Protocol field are selected, also the Associated OSPF Area
must be set.

Apply button performs a configuration change of the data.


Close button close the dialog without changes of the data.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

82/396

Figure 50.

ED

03
Ethernet Configuration

SC.3: NE MANAGEMENT

3AL 98253 ADAA

83/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 51.

8.8

Ethernet Configuration -- L2 only parameter

Reachable Address Prefixes Configuration

Select the Configuration pull down menu. Select the Comm/Routing -> OSI Routing Configuration option
and then from the cascading menu the RAP Configuration option.
The dialog-box opens and allows configuring the Reachable Address Prefix table.
Each element of the RAP table allows to link a LAPD port or a LAN port of the local NE to a separate domain;
the separate domain is selected by the address Prefixes. If the addressed element is the OS, the LAN port
will be used.
The view simulates a real notebook; it allows the user to select the pages of the notebook using the pointing
device; each page represents a particular element of the RAP table and the respective pointing device
displays the element counter.
In detail, each page contains the following data:

Physical Interface button


o

If the element is empty, displays the "none" value and allows to select a LAPD ports
or a LAN port which will be used to reach the addressed area.

If the element isn't empty, displays the selected port and allows to change it.

Area Address Prefix section allows the user to address the separate domain. The Area Address
Prefix represents a NSAP address without the fields System Id and Network Selector.

MAC Address section allows addressing the element of a domain to be reached the Ethernet LAN;
the field is managed as a simple string of 12 digits.

Apply button is used to perform a configuration change of the data contained in the complete RAP table and
close the view; the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page.
Delete button is used to delete the selected page.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

84/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Close button close the dialog without changes of the data.

Figure 52.

8.9

RAP Configuration

Manual ES Adjacencies table Configuration

Select the Configuration pull down menu. Select the Comm/Routing -> OSI Routing Configuration option
and then from the cascading menu the MESA Configuration option.
The dialog-box opens and allows configuring the Manual ES Adjacencies table.
Each element of the MESA table allows linking a LAPD port or a LAN port of the local NE to a End System
element; the ES element must be in the same area as the one of the local NE. If the addressed element is
the OS, the LAN port will be used.
The view simulates a real notebook; it allows the user to select the pages of the notebook using the pointing
device; each page represents a particular element of the MESA table and the respective pointing device
displays the element counter.
In detail, each page contains the following data:

Physical Interface button


o

If the element is empty, displays the "none" value and allows selecting a LAPD ports
or a LAN port, which will be used to reach the End System element.

If the element isn't empty, displays the selected port and allows changing it.

System Id section represents the System Id of the ES element.

MAC Address section allows addressing the element in the Ethernet LAN; the field is managed as a
simple string of 12 digits.

Apply button is used to perform a configuration change of the data contained in the complete MESA table
and close the view; the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

85/396

Delete button is used to delete the selected page.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Close button close the dialog without changes of the data.

Figure 53.

MESA Configuration

8.10 IP Configuration
The options listed in the menu Configuration > Comm/Routing > IP Configuration and also in
Configuration > Comm/Routing > Tunneling Configuration is relevant to the configuration of
messages communications for the management of ATM or IP boards (ISA) inside the equipment and in the
network.
8.10.1 IP routing configuration for ATM/IP boards management
In order to manage the ATM/IP boards inserted into the equipment, the following operations are to be done:

IP Address Configuration of PointtoPoint Interface defines the IP address for the


EquipmentController (EC). This should be the first addressing operation

Routing configuration, by means of the options:

IP Static Routing Configuration if using static routing


OSPF Area Configuration if using the automatic OSPF routing

ISA Board IP Address it defines the IP address for the ATM or IP boards (ISA); it is to be defined
for every ISA board hosted by the equipment.

NOTE: if the ISA boards are in EPS 1+1 configuration, they must have the same address)

ED

IP over OSI Tunneling it defines the OSI address (NSAP) of the destination node to be reached
(for instance the GNE connected to the TMN), when the ATM/IP management message passes

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

86/396

through an SDH/OSI network; i.e. it is to be done for every SDHNE of the network, if equipped with
ATM/IP boards.
NOTE: this addressing must be carried out at both end nodes of the tunnel, so that they can see each
other.

OSI over IP Tunneling it defines the IP address of the destination node to be reached (for
instance the IP router where the TMN is connected), when an OSI management message passes
through an IP network. It is to be defined on a a Gateway Network Element (GNE) equipped with the
QB3 interface, where the QB3 is connected to a LAN/IP network.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

NOTE: this addressing must be carried out at both end nodes of the tunnel, so that they can see each
other.

8.11 IP Static Routing Configuration


Select the Configuration pull down menu. Select the Comm/Routing -> IP Configuration and then from
the cascading menu, the IP Static Routing Configuration option.
The dialog box opens and allows configuring the parameters for IP Static Routing Configuration.
The following fields and data are present:
[1] Destination Host IP Address: allows defining the IP address necessary to reach a specific Host
[2] Destination Network: it is alternative to Destination Host IP Address; allows defining the IP Address IP
Mask to reach a network.
[3] Default Gateway IP Address: allows defining the address of the next hop gateway
[4] CLNP (Connection Less Network Protocol): allows to use a pre-define IP over OSI tunnel to towards a
gateway.
[5] IP Point-to-Point Interface Id: allows to use point to point interfaces made available by EC.
N.B. Points from [3] to [5] are alternative
Apply button is used to perform a configure change of the data contained in the column of the table and
close the view; the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page.
Delete button is used to delete the selected page.
Close button close the dialog without changes of the data.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

87/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 54.

IP Static Routing Configuration

8.12 OSPF Area Table Configuration


Select the Configuration pull down menu. Select the Comm/Routing -> IP Configuration and then from
the cascading menu, the OSPF Area Table Configuration option.
The dialog-box opens and allows configure the parameters for OSPF (Open Shortest Path First) Area Table
Configuration.
The following fields and data are present:

OSPF Area IP Address

OSPF Area Range Mask

Both fields gives a synthetically information that includes all the addresses (specific a NE and to a Network)
in an Area.
Apply button is used to perform a configuration change of the data contained in the complete RAP table and
close the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page.
Delete button is used to delete the selected page.
Close button close the dialog without changes of the data.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

88/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 55.

OSPF Area Table Configuration

8.13 IP Address Configuration of Point-to-Point Interfaces


Select the Configuration pull down menu. Select the Comm/Routing->IP Configuration and then from the
cascading menu, the IP Address Configuration of Point-to-Point Interfaces option.
The dialog-box opens and allows setting the Equipment Controller IP address used to communicate with the
ISA board.
OK button is used to perform a configuration change of the data contained in the dialog-box and closes it;
the dialog is visible until the end of the operations and a wait cursor is displayed.
Cancel button close the dialog without changes of the data.

Figure 56.

ED

03

IP Address Configuration of Point-to-Point Interfaces

SC.3: NE MANAGEMENT
3AL 98253 ADAA

89/396

8.14 ISA board IP Address


Select the Configuration pull down menu. Select the Comm/Routing->IP Configuration and then from the
cascading menu, the ISA Board IP Address option.
The dialog-box opens and allows setting the IP Address of the ISA Board that communicate with the
Equipment Controller (EC).
OK button is used to perform a configuration change of the data contained in the dialog-box and closes it;
the dialog is visible until the end of the operations and a wait cursor is displayed

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Cancel button close the dialog without changes of the data.

Figure 57.

ED

03

ISA Board IP Address

SC.3: NE MANAGEMENT
3AL 98253 ADAA

90/396

8.15 OSI over IP


Select the Configuration pull down menu. Select the Comm/Routing->Tunneling Configuration and then
from the cascading menu, the OSI over IP option.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The dialog-box opens (Figure below) and allows configuring the Remote Destination IP Address of the
Equipment Controller.

Figure 58.

OSI over IP Tunneling configuration

Apply button is used to perform a configuration change of the data contained in the complete table and
close the view; the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page.
Delete button is used to delete the selected page.
Close button close the dialog without changes of the data.

8.16 IP over OSI


Select the Configuration pull down menu. Select the Coo/Routing->Tunneling Configuration and then
from the cascading menu, the IP over OSI option.
The dialog-box opens and allows configuring the Destination NAPS Address and the IP Routing Type.
The following fields are present:

Destination NAPS Address:


A Network Service Access Point (NSAP) Address identifies a location in the network. The
first field of the NSAP address. AFI determines the NSAP format.
The AFI field is 2 characters long (2 hexadecimal digits) and, depending on the its value, the
length of NSAP address is variable from 16 characters to 40 characters:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

91/396

The value of AFI 39 identifies the ISO-DCC format of 40 characters long.

The value of AFI 47 identifies the GOSIP-V2 format of 40 characters long.


In all cases the last two fields of the NSAP address are:

System Id: uniquely identifies a NE in an area and is 12 characters long. It might be the equipment
MAC Ethernet address; level 2, inserted in the NE or the operator might select it.

Network Selector: provides the distinction among users of the network service and is 2 characters
long (value is "1d")

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In the view, the NSAP is managed as simple strings of characters without any pre-formatting
because of the variable format:

A first string of two characters that identifies the AFI field

A second string of variable length that identifies the remaining NSAP address

IP Routing: allows to choose the type of IP routing supported as follows;

OSPF (Open Shortest Path First)

RIP (Routing Information Protocol)

Both

None
If "OSPF" or "Both" options are selected, also the "Associated OSPF Area" must be set.
Apply button is used to perform a configuration change of the data contained in the complete table
and close the view is visible until the end of the operations and a wait cursor is displayed.
New button is used to insert a new page
Delete button is used to delete the selected page
Close button close the dialog without changes of the data.

Figure 59.

ED

03

IP over OS

SC.3: NE MANAGEMENT
3AL 98253 ADAA

92/396

Equipment Management

9.1

Introduction and navigation

This section deals mainly with the setting and changing of the boards present on the Equipment and
undertaking board protection operations.
Using the menu options, select the Equipment option from the View pull down menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The first level of the "Equipment Overview" representation will be displayed directly into the current window
The Equipment Overview enables a fast navigation through all levels of the equipment hierarchy. Navigation
is done from higher to lower levels.
The NE hierarchy is organized in the following way: subrack > board > port > TP.
Double clicking on the objects performs the navigation through different levels of the NE hierarchy:

The first level shows the subrack level of the Equipment view;

Further, by double clicking on a board body, the board level of the Equipment view can be reached.

Further, by double clicking on a port body contained in the board, the port level of the Equipment
view can be reached. The port view displays the inner TPs.

It is possible to go back to the upper level of representation by pressing the <ESC> key on the
keyboard;
It is also possible to:

Go back to the previous view, by selecting the Backward option from the views menu

Go to the next view, by selecting the Forward option from the view menu

N.B. Selecting in the first level of the Equipment view (subrack level)
The Show supporting equipment option from the Equipment menu, the Rack level view is presented;
further, selecting in the Rack level view the Show supporting equipment option from the Equipment menu,
the Equipment level view is presented.
In the Rack level view, two subrack are presented:

At the top the 1662SMC Subrack, named SR62C

At the bottom the Fans Subrack, named SRFAN

The Fans Subrack presence is managed with the Set option as for the boards of the 1662SMC Subrack
Further, selecting in the Rack level view the Show supporting equipment option from the Equipment
menu, the Equipment level view is presented.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

93/396

Figure 60.

ED

03
Equipment Overview -- Subracks level

SC.3: NE MANAGEMENT

3AL 98253 ADAA

94/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 61.

ED

03
Equipment Overview -- Rack level (without Fans subrack)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

95/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 62.

ED

03
Equipment Overview- Rack level (with Fans subrack)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

96/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 63.

Equipment Overview - NE level

In the Subrack view it is possible use the options offered by the Equipment menu clicking on it in the menu
bar.
Alarms indications are present at every NE level.
Details about these alarms indication are given in the Maintenance section.
All the options offered by equipment menu are described in the next paragraphs.
Set and change the boards present on the Equipment is the main function.
Board administrative state that decides on the "in/out of service" of the board is also described.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

97/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 64.

Equipment menu

Equipment setting operation are defined according the following sequences:


-

Configuration of a new board

Configure the board using the option "Set"

Change of board type

"Set out of service" the board

Configure the board using the option "Set"

Remove a board

"Set out of service" the board

"Remove" the board

9.2

Set and change or remove board/subrack

The boards can be set, changed or removed using the menu options of the Equipment view.
a ) Setting or changing a board/subrack
A new board/subrack may be created in either an empty slot or it may replace an existing Out of Service
board/subrack (without the lock symbol). In fact, the Set option is available only after selecting an empty slot
or an Out-of-service board.

ED

Click on the empty slot in which a board/subrack has to be added, or on an existing Out of Service
board in order to change it. The contour becomes highlighted to show that operations can be done
on it.

Select the Set option of the Equipment pull down menu.

The following example of dialogue box containing a list of the different types of boards/subrack is
displayed.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

98/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 65.

The list of different boards relative to an NE slot (example)

N.B. The list of boards/subrack displayed during a "Set Board" operation is restricted to those, which the
equipment may accept in the selected slot. Therefore the list will vary depending on which slot has been
selected.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

99/396

For details on the board/subrack identified by acronyms and NE physical composition please refers to the
Technical Handbook.

Choose the board/subrack/access card type required, by clicking on the corresponding item in the
list. The name of the board is highlighted. Click on the OK push button to validate the choice.
Note: In case of 4xANY Modules it is also necessary to choose the type of user supported as shown
in Figure 64.

The board/subrack representation appears on the NE view in the slot when the board change is
effective.
A lock representation appears over the boards ("in-service")

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In the Create/Modify dialogue box, the Cancel push button cancels the operation and closes the
dialogue box. The Help push button opens a Help view giving information about the context.

b) Removing a board/subrack

Click on the board/subrack to remove.


The outline of the slot becomes highlighted. This indicates that the board is selected and that
operations can be done on the slot.

If the slot you are working on is already empty no name appears under the slot.

Select the Remove option of the Equipment pull down menu.

From the confirmation dialogue box that opens you can confirm or cancel the "Remove" operation.
N.B. It is possible remove a board only if it is not involved in any type of cross connection (OH bytes
included) or Performance monitoring.

c) Modify a board
N.B. This procedure can be done to replace an existing optical module with another of different type
without previously remove it.

ED

Click on the optical module to replace. The outline of the slot becomes highlighted to show that
operation can be done on it.

Select the Modify option of the Equipment pull down menu.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

100/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 66.

A dialog box containing a list of different types of optical module is displayed.

Figure 67.

ED

Modify the module

03

The list of different types of optical module (example)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

101/396

9.3

Chose the optical module type required by clicking on the corresponding item in the list; the name of
the module is highlighted.

Click on OK push button to validate the choice.

The board representation appears on the N.E. view in the slot when the board change is effective. A
padlock representation appears over the board.

Connect Fan to CONGI board

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This command enable the Fan Subrack alarms management from CONGI in slot 10 or slot 12 according to
the option selected in the Equipment menu.
Figure below. Shows an example
Select the CONGI board
To enable this function select the Connect Fan to CONGI#1 option (or as alternative Connect Fan to
CONGI#20) of the Equipment menu if the supervision Fan Subrack cable is connected to CONGI unit
inserted in slot 1.

Figure 68.

Connect FAN to CONGI

It is possible to disable this function by selecting the relevant CONGI board and then choosing the Remove
Fan connection from CONGI#1 option of the Equipment menu.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

102/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 69.

9.4

Remove FAN connection from CONGI

Board administrative state

The operator decides to set a board in service or out of service, if the NE allows it.
N.B. In the equipment view, a lock representation appears over the boards which are in "in service" state.
9.4.1

Setting a board in service

In the Subrack NE view, click on the board in order to select it.

Select the Set in service option of the Equipment pull down menu.
A lock representation appears over the boards.

9.4.2

Setting a board out of service

In the Subrack NE view, click on the board in order to select it.

Select the Set out of service option of the Equipment pull down menu. Select the Ok push button
in the confirmation window that appears.
A lock representation disappears, substituted by the symbol

ED

03

over the boards..

SC.3: NE MANAGEMENT
3AL 98253 ADAA

103/396

9.4.3

Consulting a Board's Administrative state

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The board's administrative ("in service" or "out of service") state is indicated on the board view as shown in
the following figure.

Figure 70.

9.5

Consulting a boards administrative state

Software description

This function allows the operator to visualize information about the software(s) which is (are) present in the
selected board.

Click on a board in which the software is wanted to know (COMPACT ADM unit). The outline of the
slot becomes highlighted. This indicates that the board is selected and that operations can be done
on the slot.

Select the Software description option of the Equipment pull down menu.

Opened dialogue box contains as many folder sheets as there is software in the selected board.
Click on the Close push button to close the dialogue box.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

104/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 71.

9.6

Software Description dialogue box.

Remote Inventory

This command displays the remote inventory data present in the Subrack and Boards.

Select the Remote Inventory option of the Equipment pull down menu.
Two options are available:

Subrack level: prints or write on a file the remote inventory data of the subrack.

Board level: show the remote inventory data of the selected board

Figure 72.

Remote Inventory menu

For the Board level a dialog similar to Figure below. Appear.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

105/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 73.

Remote Inventory dialogue box

The remote inventory data of the Subrack level can be printed on the default printer or to a file in postscript
or ASCII format.

Figure 74.

Select Printer

N.B. If no printer is installed, there is no error message displayed to indicate this.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

106/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 75.

ED

03
Select Output Format for file

SC.3: NE MANAGEMENT

3AL 98253 ADAA

107/396

9.7

Show supporting equipment

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Click on Show Supporting Equipment menu option of the Equipment menu to navigate to the equipment
that supports the selected board.

Figure 76.

ED

03

Equipment Overview -- Subrack level

SC.3: NE MANAGEMENT
3AL 98253 ADAA

108/396

10 BOARD VIEW
10.1 Introduction
The Board View permits to show the physical port available in a specific board and to access the Port view.
The "Board view" is reached selecting the Equipment option in the View pull down menu, then double
clicking on the selected board to show the relevant Board view, presenting the ports.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In case of board with multi access SDH another view permits to select the SDH port.
An example of "board view" with the presented port is in Figure 78.
Alarms and Status indications referred to the board level are present at the bottom of the view, as indicated
in the example (Administrative State and Board Alarms/Status).
This information are "In/Out of service" of the board (Administrative State) and board alarms and status like
"missing" (RUM) or "mismatch" (RUTM), EPS condition if supported and other indications typical of each unit.
In the Maintenance section details on this indication are given.

Figure 77.

ED

03

Equipment view: select the SDH port on a board

SC.3: NE MANAGEMENT
3AL 98253 ADAA

109/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 78.

Example of a Board View

A port type is described with a board rectangular view and port identification.
The port identification is usually internal to the rectangular board (see Figure below. one example of optical
port)

(SDH)
Figure 79.

(ATM or IP)

(PDH)

(GBit ETHERNET)

Example of a Port identification and alarm synthesis

The following information is available:

Type of port (name)

State of port (alarm status synthesis)

Symbol of the port

The operator is provided with a representation of the port alarm synthesis on each port.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

110/396

The messages displayed at the top view provide port denomination.


The messages displayed at the bottom provide information about Board alarms.
A message under the mouse facility provides the name and the port type or the alarms name. A message
appears in the message area in the bottom left corner of the view.
By double clicking on a board view, it is also possible open the corresponding port view.

10.2 Board View Menu


Selecting the "Board" option in the menu bar the complete pull down Board menu is presented:
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

Port Access: Access the "Port" view.

Note: this option is accessible after the selection of a port contained in the view.

Change Physical Interface: Change the SPI or PPI object into PPI or SPI (and vice versa) on the bimode port (140Mbit/s / STM-1 switchable).

Show supporting equipment: Navigate to the upper subrack level.

ISA Port Configuration: It allows configuring the TPs for the ATM connections.

Figure 80.

Board menu options

These options are described in next paragraphs.


10.2.1 Port Access
Click on Port Access menu option of the Board menu to access the "Port View"
Navigation to the Port view permits to show a detailed alarm presentation of the port and to set the relevant
configurations.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

111/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 81.

After Port Access selection (example)

10.2.2 Change Physical Interface


This command allows to change the type of physical interface in a bi-mode port (140 Mbit/s / 155 Mbit/s
switchable port) i.e. it changes the SPI or PPI object into PPI or SPI
Select the Symbol of the port in the "Board view".
Click on Change Physical Interface menu option of the Board menu.

Figure 82.

Change Physical Interface

The following dialog box is opened:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

112/396

Figure 83.

Change Physical Interface dialog box

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Click on the OK push button to change the physical interface.


Click on the Cancel push button to abort the change of the physical interface.
10.2.3 Show supporting equipment
Click on Show Supporting Equipment menu option of the Board menu to navigate to the subrack that
supports the selected port view.

Figure 84.

ED

03

Subrack level

SC.3: NE MANAGEMENT
3AL 98253 ADAA

113/396

11 PORT VIEW
11.1 Introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This section describes the operations necessary for the consultation, modification and configuration of each
port.
The Port View permits to set and show the transmission resources (i.e. the Termination Point, TP) referred to
the specific Port; it permits to check the detailed alarms presented by each TP of the Port, and the
available menu permits to configure the port, (many setting options listed in the port menu are common
with the "Transmission" view).
In these views are presented only the TP specific of the port.
The menu differs according the port type (SDH, PDH, HOA, ATM/IP/ETH).
The Port View can be accessed from the Equipment or Transmission Views.
The "Port view" is reached selecting the Equipment option in the View pull down menu then double clicking
on the presented rack/subrack to present the subrack view, as described in chapter "Show supporting
equipment"
Double clicking on the selected board the relevant Board view is available presenting the ports.
By double clicking on a board view, the corresponding port view is opened.
The "Port view" is also reached selecting the Transmission option in the View pull down menu.
Then the Add TP option of the Transmission menu permits to select and confirm a TP.
On the transmission view, which appears, select the TP and on the Transmission menu select the Navigate
to a port view option.
The HOA port view can only be reached from the Transmission view, selecting a VC or TU TP.
The ATM/IP/ETH TPs are not automatically created when the board is inserted in the subrack but must be
created as explained in chapter ATM/IP/ETH Configuration
From the Port view It is possible to Navigate to Transmission view.
The port types contain the following TP:

ED

SDH port: Electrical or Optical SPI TTP, RS TTP, prot TTP (MSP TTP), AU4 CTP, Trail Monitor (only
with enabled POM)

PDH port: PPI TTP, En CTP, VCn TTP

HOA port: VC4 TTP, TUG3, TUG2, TU3, TU12, Trail Monitoring (only with enabled POM)

ATM port: VC4C TTP, VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP and E1 TTP

PR_EA port: VC4 TTP, VC3 TTP and VC12 TTP

Fast ETHERNET port: MAU, PTC, VC3XV, VC12XV, VC4 TTP, VC3 TTP and VC12 TTP

Gigabit ETHERNET port: MAU, PTC, VC4XV, VC4 TTP, VC3 TTP and VC12 TTP

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

114/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 85.

Example of a SDH Port View

On the port view, the messages displayed at the top view in the form of message boxes provide more
information concerning the type and the alarms of the port.
On the other hand the messages displayed at the bottom provide information about MSP protection and ALS
state (if they are supported).
A message under the mouse facility provides the name and the port type. A message appears in the
message area in the bottom left corner of the view.

11.2 Port View: elements on the TP


The symbols of the TPs have the following meaning:

Alarm Icon Area


The icon boxes represent alarms. The color of the boxes changes according to the alarm severity.

TP Role
The icon boxes represent the function: Adaptation, Termination or Compound Adaptation and
Termination.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

115/396

Cross-connected state
If the condition of the resource is cross-connected, an icon with a x appears beneath the box.

Performance State
If the condition of the resource is under performance monitoring, an icon with a P appears beneath
the box.

Loop state
If the condition of the resource is under loop, an icon with a L appears beneath the box

Selected state

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

An orange frame around the box identifies the TP selection, so port menu refers to the selected TP.

Figure 86.

Figure 87.

ED

03

Termination TP box.

G.783 Adaptation TP box.

SC.3: NE MANAGEMENT
3AL 98253 ADAA

116/396

11.3 Port View Menu


Selecting the "Port" option in the menu bar the complete pull down Port menu is presented.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The menu differs according the port type (SDH, PDH, HOA and ATM), and is introduced in the following:

TP configuration: Set parameters for the Signal Label and Path Trace overhead on Synchronous
TP's.

TP Threshold Configuration: Set B2 excessive BER and Signal Degraded parameter

TP Frame Configuration: Set parameters for 2Mbit/s G.703/G.704 or ISDN-PRA management.

Set Retiming: Enable/disable the retiming feature on the outgoing 2 Mbit/s signal.

AU4 Concatenation: Only for SDH ports views.

Cross Connection: Manage the connection of the paths.

Monitoring Operations: Set parameters for POM/SUT and TC (Tandem Connection) TPs. Not
available for PDH port.

Performance: See and Show Performance Monitoring parameters and data.

Loopback: Manage the loopback commands, for commissioning or maintenance purposes

MSP Manage the Multiplex Section Protection of the NE.

Physical Media: Manage the physical setting of the TP of the port. Not applicable to HOA port. It is
described in the following paragraph.

Show supporting board: Navigate to the upper board level. It is described in this chapter.

Navigate to Transmission view: permit to show a complete overview about the signal flow, opening
all TP's

Navigate to Monitor view: permit to show an overview about the monitoring operation (POM, SUT,
TC) all TP's.

Figure 88.

Examples of port menu options (SDH, PDH and ATM port)

11.4 Set Retiming


The Retiming feature applies to the outgoing 2 Mbit/s and its purpose is absorb the jitter / wander that is
transferred to the PDH signal when SDH pointer justification occur. The feature is set individually per port.
Select a 2Mbit/s port and zoom in to open the port view.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

117/396

When the Retiming feature is disabling, the color of the state information at the bottom of the window is
brown and the label "Retiming State Disable" is written.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Set Retiming->Enable option from the Port menu.

Figure 89.

Set Retiming enable (before)

As result of this operation the state information color become green and the label "Retiming State Enable" is
written.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

118/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 90.

Set Retiming enable (after)

11.5 AU4 Concatenation


Select a STM-16 or STM-4 optical interface to configure as AU4 concatenation structure.
Zoom in to open the board and then the port view menu.
Select the AU4 Concatenation option from the Port menu to open Figure below. (In this example a STM-16
view is shown)
The STM-16 stream appears divided into different groups: not all AU4s can be chosen as first AU4 but only
AU4#1 AU4#5, AU4#9, AU4#13 for AU4c. Therefore for concatenated action of for AU4s in one AU4c these
AU4 streams are deleted and substituted by the new AU4c component.
Select the supported concatenation Number =4 (selection 64 is not operative) to visualize the available
group/groups then select the group to concatenate and click on the Concatenate push button.
Click on the Cancel key to exit and come back to the previous window.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

119/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 91.

AU4 concatenate/deconcatenate commands

The Concatenate button will be enabled and the Deconcatenate button will be disabled when is selected a
non concatenated AU4, vice versa when is selected a concatenated AU4.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

120/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 92.

Example of a concatenated AU4 transmission view

The port view represented in Figure up. Shows an STM4 interface with four AU4 concatenated in one AU4c.
The AU4c appears as a single icon that has the same size of the actual AU4 blocks. The AU4c streams
support the Alarm synthesis, Cross-Connection states and Performance Monitoring information as standard
AU4 streams.
To deconcatenate an AU4c select again the "AU4 Concatenation" option in the Port View menu and then
select the AU4c to deconcatenate. Click on the Deconcatenate push button to apply the command or on
Cancel to exit.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

121/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 93.

Example of a concatenated AU4c

11.6 Physical Media option menu


The Port -> Physical Media options permit to set physical configuration of each TP of the port.
The Physical Media options are also accessible from the Transmission menu.
It opens a menu that differs according the port type:

SDH port:
- ALS Management
- Show Optical Configuration
- Tx Quality Configuration
- Single Fiber Configuration
- LAPD Configuration
- Ms Configuration

PDH port:
- Line Length Configuration.
- HDSL Configuration. Not operative
- NT G703/704 Configuration. . Not operative
- NT X21 Configuration. . Not operative

ETHERNET port:
- Remote Laser Management. Not operative

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

122/396

- ALS Management. Not operative


- Ethernet Port Configuration
- Ethernet Mapping Protocol.
- ATM/IP/ETH Configuration
- Control Path Activation.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

These options are described in next paragraphs except the previously referenced.

Figure 94.

Physical media menu (SDH port example)

11.6.1 Automatic Laser Shutdown Configuration


The aim of this paragraph is to describe the optical port hence the laser sources.
Automatic laser shutdown (ALS) is useful in case of a loss of communication between two NEs due to optical
fiber breakdown. For safety reasons it may be necessary to shutdown the laser to enable the fixing of the
communication link.
The automatic laser shutdown function can only be configured from the optical ports of the equipment.
Select the SPI block in the port view and then select the Port pull down menu.
Select the Physical media option and then from the cascading menu the ALS Management option.
The Automatic Laser Shutdown State dialogue box opens.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

123/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 95.

Automatic Laser Shutdown Management

The dialogue box enables the ALS Management and the Restart parameters. The following actions are
available
a) Allow Automatic Laser Shutdown.
To allow the automatic laser shutdown functionality, select the ALS Enabled option of the ALS
Function: option button.
b) Forcing the Laser to start or stop.
When the laser is forced to ON or OFF, it is restarted or stopped and the Automatic Laser Shutdown
is disabled, if it was not already so.
1) Force laser ON.
To carry out a laser forced ON, select the Laser Forced ON option of the ALS Function
then click on Apply and then or close push button to close the dialogue.
2) Force laser OFF.
To carry out a laser forced OFF, select the Laser Forced OFF option of the ALS Function
then click on Apply and then or close push button to close the dialogue
c) Delete: this option deactivates the ALS function, returning to the state.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

124/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

From this window it is only possible to create the ALS function (all ALS commands are grey)

Figure 96.

Automatic Laser Shutdown Management (after ALS Function delete)

d) Enabling or Disabling Automatic / Manual Laser Restart.


To enable (disable) an automatic laser restart following an automatic laser shutdown
(periodic restart), select the Enabled (Disabled) option of the ALS Auto Restart. The laser
will be ON for 2 secs and OFF for 70 secs, in periodic mode. The same procedure is
applicable for the ALS Manual restart: while the ALS auto Restart is disabled, the manual
restart permits to permits to perform a laser restart for single time period.
e) Wait to restart time
The Wait To Restart Time: field indicating the delay period in seconds, occurring before an
automatic laser restart is launched (following an automatic shutdown). The restart time
period for this equipment is fixed to 70 secs.
f) ALS Manual restart
When the ALS Manual Restart is Enabling it is possible to enter two different commands:
Manual or Test Restart. The manual command immediately activates a single laser restart:
this command overrides the wait to restart time. The test restart is similar to the manual
restart but the laser remains "ON" for a longer time in order to make a measurement of the
received optical power.
When all the different parameters have been configured, select the Apply button to confirm the setting and
close the dialogue box.
Selecting only the Close button allows you to cancel the choices made.
Note that the ALS procedure is activated ( if enable ) only when the fiber has been interrupted and the ALS
state has not to be confused with the laser state.
ALS states (see example of), displayed by the functional state message area of the optical port, are:
ALS states:
Inactive = No ALS has been activated (Off) or the laser has been Forced ON/OFF.
In test = the laser restart has been automatically activated.
Active = The ALS has been activated (On).
Undefined = The ALS is not present (not created).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

125/396

Laser state:
On = all OK or ALS not present (not created).
Off = Laser off (when ALS is created).
Forced on = ALS forced on by operator command.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Forced off = ALS forced off by operator command.

Figure 97.

ALS and Laser current state (example)

11.6.2 Show Optical Configuration


This command permits to get detailed information on the optical characteristics of the port that is visualized.
Firstly select an optical board and the SPI block, then click on Show Optical Configuration option from the
Physical media pull down menu to visualize the parameters of the selected optical port.
Shows an example of the parameters of the selected interface.
N.B. This dialogue box can only be read. You cannot write in the entry boxes.

Figure 98.

Visualizing a port optical parameters

The laser ports are identified by three major characteristics:

ED

STM Level: describes the input/output optical interface types: STM1/STM4


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

126/396

The wavelength of the laser source: the units are nanometers (nm = 10-9 m).

The use of the port: describes whether the laser port is used for interoffice transmissions on long
distances (Long Haul) 40 km) or for interoffice transmissions on short distances (Short Haul ] 15
km).

The Colored Interface Parameters section is not applicable in the current release
To close the dialogue box click on the Cancel push button.
11.6.3 Single Fibber Configuration

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The single fiber configuration can be realized with passive optical couplers.
The optical coupler must not loop the Tx signal onto the local Rx.
For this purpose and in general to avoid a low Tx/Rx decoupling also when the optical line is interrupted, an
identification label has been assigned to the local Tx side; the Rx part in the remote receive side checks the
congruency between the received and the expected labels. If a signal label mismatch is recognized on the
received section, an alarm (AIS and RDI) will be generated. Example of Figure below. Shows that are
accepted the label "1" from Tx1 to Rx2 while is accepted label "2" from Tx2 to Rx1.

Figure 99.

Bidirectional Transmission on a single fiber

Select the Physical media option and then from the cascading menu the SDH Single Fiber Configuration
option.
In the figure that opens, the following fields have to be considered:

Allow Single Fiber - select the transmit mode on the single fiber (enable or disable).

Transmitted Section:
Transmitted Media Byte - assigned label to Tx (0-14)
Transmitted Media Type - overhead byte used for the communication:
- Media Dependent byte of Regeneration Section or
- S1 byte of Multiplex Section (the part not used for the SSM)

ED

Received Section:

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

127/396

Received label

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Expected label (0-14)

Figure 100.

Single Fiber Configuration View

11.6.4 Ms Configuration
The Ms Configuration menu allows the SS bit provisioning for Multiplex Section Object (MSTTP) in
SONET/SDH network interworking.
Select the MSP TP.
Click on Ms Configuration menu option of the Port menu.
This dialog allows selecting between SDH or SONET networks. After the selection click on Apply and then
on Close to close the dialog.
Ms Forced AIS is not supported in the current release.

Figure 101.
ED

03

Ms Configuration

SC.3: NE MANAGEMENT
3AL 98253 ADAA

128/396

11.6.5 Line Length Configuration


To manage the Line Length configuration click on Line Length Configuration menu option of the Physical
Media menu.
This dialog allows configuring the line length for a PDH PPI TP of a 45 Mbit/s port.
The OK button validates the configuration and closes the dialog box.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Cancel button removes the dialog

Figure 102.

PDH Line Length Configuration View

11.6.6 Ethernet Port Configuration


To set Ethernet port parameters, select the Ethernet Port Configuration option of the Port -> Physical
Media menu as shown in Figure below.

Figure 103.

Ethernet Port Configuration options

Subsequently Figure below. Will be opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

129/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 104.

Ethernet Port Configuration Dialog

For the Fast Ethernet (10/100 Mbit/s) port it is possible to choose between two Configuration Type:
1. Auto navigation : enable allows to configure the "Rate" to be negotiated (10 or 100 Mb/s). The
"Directionality" (Full Duplex) and the "Flow Control" (Activated) are always enabled and can't be
changed.
2. "Manual: allows forcing the "Rate" at 10 or 100 Mb/s.
The "Directionality" is always Full Duplex.
Moreover It is possible to Restart the Auto Negotiation by depressing the relevant button; if parameters
has been changed before pressing the Restart button, a question dialog is displayed to advice that the user
has changed data but not applied them.

Figure 105.

Information dialog

In read only mode there are indication if the Auto negotiation on remote side is activated (Remote Auto
Negotiation) and what parameters are allowed on remote (Remote Allowed Parameters).
In both cases is possible to check the Auto negotiation Current State with the possible massage:
Completed OK
Completed KO
Configuring
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

130/396

Deactivated
Parallel Defect Fail
Other
At the bottom of the port view are displayed the following indications:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Interface Type:

S1000 Base SX (only for Gigabit Ethernet board)

S1000 Base LX (only for Gigabit Ethernet board)

S1000CX (only for Gigabit Ethernet board)

S100BaseTX

S100BaseFX

Unknown

S10BaseT

The Bit Rate (only for fast Ethernet board):

10 Mb/s

100 Mb/s

Figure 106.
ED

03

Gigabit Ethernet port view (example)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

131/396

11.6.7 Ethernet Mapping Protocol


Select a VC TP.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Click on Port Ethernet Mapping Protocol option of the Port> Physical Media menu. Figure below opens.

Figure 107.

Ethernet Mapping Protocol (EXAMPLE)

This dialog aims to show the actual Ethernet mapping protocol used and allowing the user to change it. The
options available are the following:
FAST ETHERNET boards:
GFP null extension Header with FCS
GFP null extension Header without FCS
GFP for packed concatenation extended
GIGABIT ETHERNET boards:
GFP null extension Header with FCS

GFP null extension Header without FCS


11.6.8 Control Path Activation
This dialog allows modifying the state of the Ethernet port virtualTPs.
Select a TP in the Ethernet port view window.
Click on Control Path Activation option of the Port> Physical Media menu.
A new window will be opened; a similar window is display when a new concatenated VCX is created in the
ISA/IP/ETH configuration window.
This dialog aims to show the activation state of the virtualTPs present in the Ethernet Port View and to
change the number of virtualTPs active.
The Active state is reached by choosing the number of Virtual TPs to be active and click on the Apply
button.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

132/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 108.

Control Path Activation (example on Fast Ethernet board)

On the contrary to change in Idle the Active state of a TP decrease the Virtual TPs to be active field and
then and click on the Apply button.
Click on the Refresh button to update the changes.
Click on Close button to close the Control Path Activation window.
Example figure below is the Active state.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

133/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 109.

Control Path Activation:Range Path mode

11.6.9 LCAS Configuration


11.6.9.1 LCAS Introduction
The LCAS protocol is supported since R. 2.1 in ISA Ethernet Switch board at STM-1 ES1-8FE/8FX and since
R.2.2 in ISA Ethernet switch at STM-4. Board and ISA Gigabit Ethernet (GETH-MB).
11.6.9.1.1 LCAS parameters
The indication that LCAS protocol can be activated on a virtual concatenation group is represented by the
instantiation of the conditonal package lcasControlPackage on vc-nXVritualTTP (n=12, 3, 4). The following
conditonal packages have to be instantiated on vcnXVirtualTTP (n=12, 3, 4) for supporting lcas specific
parameter:

MaxDifferentialDelayPackage for reporting the max supported (by the board) differential delay and
for configuring the maximum tolerated differential delay; the default value has been chosen at
48(ms).

RsAckTimeoutPkg for configuring the timeout of re-sequence acknowledge; the default value has
been chosen at 512 (ms) .

Note: the conditional packages tsdContributionPkg, holdOffTimeAndWTRPackage have not to be


instantiated.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

134/396

11.6.9.1.2 LCAS operations


The action controlPathActivation allows to activate (ADD) more than one member (vc-nVirtualTTP) with a
single manager request.
Similarly is possible to de-activate (REMOVE) more than one member (vc-nVirtualTTP) with a single
manager request.
The capability of de-activating (REMOVE) specific members ( vc-nVirtualTTP) is supported, this

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

functionality is not working if LCAS protocol is not activated, but its possible to de-activate from last active
member. Simmetrically the capability of activating (ADD) specific members ( vc-nVirtualTTP) is supported.
The activation of LCAS protocol on a virtual concatenation group already working is possible, but its a trafficaffecting operation since it requires to de-activate all members before LCAS enabling.
The symmetrical operation (even if not meaningful) of de-activing the LCAS protocol on a virtual
concatantion group already working is possible, such operation impacts the traffic bandwidth transmission
since it requires of remaining with only the vc-VirtualTTP with ID=1 as active member.
11.6.9.1.3 LCAS protocol information
For monitoring the LCAS protocol the LcasMonitor action is provided; some parameters returned by the
action are defined as Optional, the following ones are expected to be anyway returned:the number of
working members in tx, the number of working members in Rx, the member identifier reference for MST
(TBC), the received rs-ack bit (TBC), the transmitted rs -ack bit (TBC), the differential delay of each member.
11.6.9.1.4 Alarm indications
If the LCAS protocol is activated the following alarm indications can be raised:
At virtual path level (vc n Virtual TTP, n=12, 3, 4)

Member Not De-skew-able (probable Cause excessive Differential Delay): when the virtual path has
a differential delay which cant be compensated; if LCAS is not activated this alarm corresponds to
Loss Of Alignment alarm raised at virtual group level (virtual PTC). at virtual concatenation group
level (vc-nX Virtual TTP, n=12, 3, 4):

Loss Of Partial (probable Cause bandwidth Reduced): when one of active members vc-n Virtual TTP)
is affected by SSF, TIM, UNEQ, L OM or Excessive Differential Delay.

Loss Of Total (probable Cause server Signal Failure): when all the active members are affected by
SSF,TIM, UNEQ, LOM or Excessive Differential Delay.

LCAS protocol failure (probable Cause communications Protocol Error) raised when inconsistent
sequence numbering of the members is received or the CRC error control fails on LCAS multiframed
packet.

11.6.9.2 LCAS Configuration


This dialog allows modifying the state of the Ethernet port.
Select a TP in the Ethernet port view window.
Click on LCAS Configuration option of the Port> Physical Media menu.
A new window will be opened; a similar window is display when a new concatenated VCX is created in the
ISA Port configuration window.
This dialog aim is LCAS (Link Capacity Adjustment Scheme) protocol management of the TPs present in the
Ethernet Port View.
The button "Apply" will set the configuration if the LCAS protocol is enabled.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

135/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In the following picture we can note that are managed all the attributes described before and the two actions
are managed by means of the two buttons (Enable/Disable and Monitoring...).

Figure 110.

LCAS Configuration

The "Monitoring..." button start the "LCAS protocol monitoring" view like the figure below.

Figure 111.
ED

03

LCAS Monitoring

SC.3: NE MANAGEMENT
3AL 98253 ADAA

136/396

The LCAS Monitoring window is divided in two section, the first reports information concerning the Virtual
Concatenation Group Monitoring Parameters, the second reports the Channels Monitoring Parameters.
Virtual Concatenation Group Monitoring Parameters fields description:
Active Channel Number: display the number of Vcs active on Source and Sink read on Node A.
Acknowledge Bit (ReSequence Acknowledge) Source and Sink: when a renumbering of the
sequence numbers of the members sending in CTRL field NORM, DNU, EOS, or when a change of

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

the number of these members is detected at the Sk, a notification to the So per VCG has to be
performed by toggling (i.e. change from 0 to 1 or from 1 to 0 ) the RSAck bit.
MST Channel Ref.: indicates wich channel of the VCG is the reference one for MST information;
MST information report the member status from Sk to So with two states: OK or FAIL (1 status bit
per member).OK = 0, FAIL = 1.
VCG Master: indicates wich channel is the reference channel for the Differential Delay calculation.
Channels Monitoring Parameters fields description:
The first column contains the channel identifier inside the VCG (called Sequence Number) .
Tx CTRL Packet: Message sent (ADD, DNU, IDLE, NORM, EOS, FIXED), relative to a traffic flow
from Node A to Node B; it provides the status of the individual member of the group as reported in
the following:

Fixed: this is an indication that this end uses Fixed bandwidth (nonLCAS mode)

Add: this member is about to be Added to the group

Norm: Normal transmission

Eos: End of Sequence indication and Normal transmission

Idle: this member is not part of the group or about to be removed

Dnu: Do Not Use (the payload) the Sk side reported FAIL status

Unknow

Rx Channel State: MST indication (OK/FAIL) relative to a traffic flow Node B to Node A;
Rx CTRL Packet: Message received (ADD, DNU, IDLE, NORM, EOS, FIXED), relative to a traffic
flow from Node B to Node A; it provides the status of the individual member of the group as reported
in the following:

ED

Fixed: this is an indication that this end uses Fixed bandwidth (nonLCAS mode)

Add: this member is about to be Added to the group

Norm: Normal transmission

Eos: End of Sequence indication and Normal transmission

Idle: this member is not part of the group or about to be removed

Dnu: Do Not Use (the payload) the Sk side reported FAIL status

Unknow
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

137/396

Tx Channel State: MST indication (OK/FAIL) relative to a traffic flow Node A to Node B;
Differential Delay: it is calculated respect to the Virtual Concatenation group Master channel,
relative to a traffic from Node B to Node A .
TxVC: contains the sequence number assigned to a specific member from Node A to Node B. Each
member of the same VCG is assigned a unique sequence number, starting at 0.
RxVC:contains the sequence number assigned to a specific member from Node B to Node A. Each
member of the same VCG is assigned a unique sequence number, starting at 0.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Refresh button refreshes the values displayed.

11.7 TP Frame Mode Configuration


This menu item enables the configuration of the most important transmission parameters concerning the
Primary Rate Access (PRA) and G.703/G.704 frame management.
PRA management
The PRA functionality performs termination bidirectional function for Time Slot 0 on framed with CRC4 2
Mbit/s signal.
In detail, it extracts in sink direction and writes in source direction particular bits (E, Sa5, Sa6 and A) of the
Time Slot 0.
Moreover, it generates substitution frames in case of detection of LOS on the signal coming from a
Terminal Equipment.
The PRA functionality has been extended in order to manage proprietary handling of the bits of Time Slot 0
(Framed with leased line PRA option) in terms of state, defect detection and consequent actions.

G.703/G.704 management
This functionality allows to activate the adaptation function to process a framed (G.704 interface) or not
framed (G.703 interface) 2Mbit/s signal.
This TP Frame Mode Configuration option is available for: P12CTP
Select the desired P12CTP and then the Port >TP Frame Mode Configuration option.
TP Frame Mode Configuration can also be accessed from the Transmission and Synchronization view
menu.
The following dialog appears:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

138/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 112.

TP Frame Mode Configuration

The windows contains the following graphical objects:

Framed Signal Mode that allows to configure the attribute framed Signal Mode; the user can choose
one of the following value:

Not Framed (G.703 interface): the PRA function cannot be activated;

Framed without PRA (G.704): the behavior according to ETS 300233 is applied in the handling of
bits of Time Slot 0 in terms of state, defect detection and consequent action;

Framed with PRA: PRA function is activated

Framed with leased line PRA: a proprietary leased line behavior is applied.

CRC4 Status that defines the monitoring capabilities applied to the signal with a CRC multiframe:

Operation: allows configuring the CRC4 processing modalities; the possible value is:

ED

Disabled that disables the CRC4

Forced that configures CRC4 with consequent actions


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

139/396

Automatic that triggers the CRC4 algorithms in order to allow interworking of pieces of equipment
with and without a CRC4 capability.

Monitoring Enabling: enable or disable the CRC4 error counting

Remote Indication: readonly field that indicates if status of CRC4 error counting functionality of
farend NE is enabled or disabled.

Loss of Synch Consequent Action allows to perform the consequent action on the transmitted
2M/s signal with retiming when the CRU is in Holdover or Free running mode; the consequent action is
performed only if PRA or leased line application ha been configured on the associated P12CTP.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Frame Status is a readonly field that reports an indication of the received signal:

No indication

The 2Mb/s signal is multiframe

Press Ok to apply the parameters or Cancel to close the dialog.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

140/396

11.8 Show Supporting Board


Select a TP.
Click on Show Supporting Board menu option of the Port menu to navigate to the board that supports the
selected port view.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure below. (Example) opens.

Figure 113.

ED

03

Board View Example

SC.3: NE MANAGEMENT
3AL 98253 ADAA

141/396

11.9 Navigate to Transmission View


Select a TP.
Click on Navigate to Transmission View menu option of the Port menu to navigate to the corresponding
Transmission View that is related to the selected TP.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Navigation to the Transmission view permits to show a complete overview about the signal flow as for the
example of the following figure.

Figure 114.

ED

03

Navigate to Transmission view selection

SC.3: NE MANAGEMENT
3AL 98253 ADAA

142/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 115.

After Navigate to Transmission view selection

11.10 Navigate to Monitoring View


Select a TP where are configured some Monitoring Operations (POM, SUT, TC)
Click on Navigate to Monitoring View menu option of the Port menu to navigate to the corresponding
Monitoring View that is related to the selected TP.
Navigation to the Monitoring view permits to show a complete overview about the Monitoring Operations
(POM, SUT, TC) as for the example of the following figure.
In figure below is shown an example of Monitoring View of a TP with POM and TCM both before and after
matrix.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

143/396

Figure 116.

ED

03
View of Monitoring Operations (example)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

144/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

11.11 Port Mode Overview

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Click on Port mode option of the Configuration> Port mode menu. Figure below.

Figure 117.

Figure 118.

Port Mode Menu Option

Port Mode Overview Dialog

You can select the port type you want to see, and click the search button to list them. As below, then you can
click the port you want to set at the found port list table. And set the port mode.
Port Mode Overview Dialog allows a centralized mechanism for:
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

145/396

System wide search for Port Mode settings


Change of Port Mode setting
Change of Port Mode default.
System wide search capability is offered in order to show port mode value representation for all ports in a NE
or in a port subset.
The subset is defined according to the filtering capabilities on Port Type (all ports, SDH port Only, PDH port
Only, Ethernet port only, CWDM port only) and to the Port Mode set (Ignore, Mon, Auto).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To prevent alarms from being raised and failures being reported during trail provisioning actions, trail
termination functions have the ability to enable and disable fault cause declaration.
This is controlled via their termination point mode or port mode parameter.
The termination point mode can be either monitored (MON) or not monitored (NMON). The state can be
MON if the termination function is part of a trail and provides service and NMON if the termination function is
not part of a trail or is part of a trail which is in the process of set-up, breakdown or re-arrangement.
In physical section layers, the termination point mode is called the port mode. It has three modes: MON,
AUTO, and NMON (the last is not supported).
The AUTO mode is like the NMON mode with one exception: if the LOS defect clears, the port mode is
automatically changed to MON. This allows for alarm-free installation without the burden of using a
management system to change the monitor mode.
Change of Port Mode setting can be done on the selected ports in the matrix gadget. Multiple selection is
allowed. The user can choose the new Port Mode ( in the Define Port Mode Values field) and can start the
change on the selected ports (Set Mode).
Change of Port Mode System Default can be done in the related frame Current system default is visualized
in the combo box current value. Port Mode Overview dialog is available both at Configuration menu and Port
View menu and Transmission View as well. Using it at Configuration menu the multi port working mode is
enabled with full support for search and filtering. Using it in Port View or Transmission View enable the
single port functionality and the search capability is greyed out.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

146/396

Figure 119.

ED

03
set the selected port mode

SC.3: NE MANAGEMENT

3AL 98253 ADAA

147/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

12 Equipment Protection management (EPS)


12.1 Introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

It is unthinkable to launch a telecommunications system, handling millions of communications, without the


possibility of replacing equipment in a real time way, consequent to equipment failure. Everything must be
done so that the communications can continue smoothly and so that the equipment failure remains
transparent to the users. Protection management deals with this aspect of the EML-USM.
Switching the board supporting the protected service when this board fails to a protecting board capable of
supporting the same service performs the protection. This protection is realized according to a protection
scheme.
An equipment protection scheme is composed of the following parameters, which can be configured:

Group type: 1+1 or 1+n


The group type specifies if one or more unreliable resources for protection can be assigned to one or
more reliable resources. 1+1 group type means that one protecting unit protects a working element.
1+n group type means that only one protecting unit protects n working elements.

Protection priority:
A priority can be assigned to protected units in 1+n protection schemes. This priority can be 1, 2, ...
or n, 1 being the highest priority.

Configuration type: revertive or non revertive


In revertive mode, a protected service will be switched back to its protected element when it has
recovered from its failure.
In non-revertive mode, the switch to the protecting element is maintained even after a recovery from
failure.

Protection wait to restore time:


Used when revertive mode is active, the protection wait to restore time prevents several protection
switches due to an intermittent failure. A protected element must be fault free during this fixed period
of time before a protected service is switched back to it.

Board duplication remains the easiest way to ensure equipment protection in a system.
The actions that can be undertaken are of the following type:

Consult and modify an Equipment Protection Scheme (EPS),

Manual Switch EPS,

In Board view, the board whose content is represented is considered as implicitly selected.
The functional state message area of the boards involved in an equipment protection scheme displays EPS
protection states.

12.2 Management: consulting and modifying EPS


In order to consult EPS, perform the following operations:
The "Port view" is reached selecting the Equipment option in the View pull down menu to present the
subrack view.

ED

Select the Equipment option in the View pull down menu.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

148/396

Select the EPS pull down menu. Then select the Management...

Figure 120.

Consulting EPS

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following dialogue box is opened.

Figure 121.

EPS Management dialogue box

The EPS Management dialogue box shows the current NE protection schemes in the left side. The list
gives for each protecting board the protected board(s).
The available protection schemes are coherent with the NE type and release.
The right side of the dialogue box allows modifying the EPS configuration.
The current release of this NE fixes the following protection:

N+1 (with N 3) "P63E1 or P63E1N" protection


- Board of slot MAIN (protected): P63E1 or P63E1N, slots 7 to 14.
- Board of slot SPARE (protecting): P63E1 or P63E1N, slots 7 to 14.

N+1 (with N7) "P3E3/T3" protection


- Board of slot MAIN (protected): P4E3/T3, from slots 7 to 14.
- Board of slot SPARE (protecting): P3E3/T3, from slots 7 to 14.

N+1 (with N 7) "P4ES1N" protection


- Board of slot MAIN (protected): P4ES1N, from slot 7 to 14.
- Board of slot SPARE (protecting): P4ES1N, from slot 7 to 14.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

149/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

N.B. For P3E3/T3 and P4ES1N more than one protection group N+1 revertive can be created, depending
on the equipment configuration. The spare board position can be assigned in a flexible way. The only
constraint is the following:

The access card corresponding to the protecting board must be an HPROT card

The HPROT card has to be plugged at the left side of the access card group

The main/spare boards have to be adjacent

The protecting board has to be plugged at the left side of the protected group of boards

The protecting/protected group of ports have to be of the same type

1+1 "ATM MATRIX 4x4" protection


The ATM MATRIX board can be protected in 1+1 equipment protection scheme. In this configuration
the ATM MATRIX and all indirect interfaces connected to it are protected against ATM module failure.
This does not apply to the local STM-1 interface so the traffic on it is lost. A maximum of two
protection group 1+1 not revertive can be created. The spare card position can be assigned in a
flexible way; no restriction for position of main and spare ATM MATRIX is present.

1+1 "ATM MATRIX 8x8" protection


The ATM MATRIX board can be protected in 1+1 equipment protection scheme. In this configuration
the ATM MATRIX and all indirect interfaces connected to it are protected against ATM module failure.
A maximum of two protection group 1+1 not revertive can be created. The spare card position can
be assigned in a flexible way; no restriction for position of main and spare ATM MATRIX is present.

1+1 ISA PR_EA (PREA4ETH, PREA1GBE) protection


The ISA PR_EA boards can be protected in 1+1 equipment protection scheme. In this configuration
the ISA PR_EA and all indirect interfaces connected to it are protected against module failure. This
does not apply to the local interface so the traffic on it is lost. A maximum of two protection group
1+1 not revertive can be created. The spare card position can be assigned in a flexible way; no
restrictions for position of main and spare ISA PR_EA are present.

1+1 ISA ES-16 protection


The ISA ES-16 boards can be protected in 1+1 equipment protection scheme.In this configuration
the ISA ES-16 and all indirect interfaces connected to it are protected against module failure. This
does not apply to the local interface so the traffic on it is lost.A maximum of two protection group 1+1
not revertive can be created.The spare card position can be assigned in a flexible way; no restriction
for position of main and spare ISA ES-16 are present.

1+1 "COMPACT ADM" protection


- Board of slot 6, COMPACT ADM main (protected)
- Board of slot 15, COMPACT ADM spare (protecting)

N.B. For each type of failure on the MATRIX main board (CRU, Shelf Controller) a switch is performed to
the spare boards
The COMPACT ADM protection is automatically presented in the left side of the dialog box when
the SPARE COMPACT ADM is created in the Set option of the Equipment menu. It is not created with
the EPS menu described in this chapter.
This right side is divided into two parts.
The upper part provides a message field with the name of the Protecting board and a choose button to
display the list of boards available.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

150/396

The lower part provides a list to display the Protected boards currently in the displayed scheme.
A choose button is provided to display the list of boards which could be added as protected.
A delete button enables user to remove a protected board from a scheme.
a) Scheme displaying
To display a specific scheme, user selects an item on the left list.
This operation fills the protecting element text field and the protected list with the board user name. If user
clicks where there is no item displayed, the right part is displayed empty.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Cancel push button closes the dialog box.


b) Scheme creation
To create a new protection scheme, don't click on item in the left list.
In this way the right part is displayed empty and the Choose Protecting button is sensitive.
Press this button to displays a window to choose a board in the "Board Selection" list. The board are listed
opening the NE>rack>subrack levels.
After that operation, Choose Protecting button becomes insensitive and Choose Protected becomes
sensitive.
The user can add, always using the same "Board Selection" list dialogue box presented, as many protected
boards as wanted.
When the right part of window is correctly filled, the OK button close the dialog box and create the scheme
(the new list is update re-opening the EPS Management dialogue box).
The Cancel push button cancels the creation and closes the dialog box.
c) Scheme deletion
To delete an existing protection scheme, the user selects a scheme in the left list. Using the Delete button,
ser could delete the scheme.
d) Scheme modification
To modify an existing protection scheme by adding or removing protection units, the user selects a scheme
in the left list. Using Choose button for protected elements, user could add protected boards.
By selecting a protected board and using the Delete Protected button, user could remove protected
elements from scheme. When the right part of window is correctly filled, the OK button close the dialog box
and modify the scheme.
The Cancel push button cancels the creation and closes the dialog box.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

151/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 122.

ED

03
EPS: board selection

SC.3: NE MANAGEMENT

3AL 98253 ADAA

152/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 123. EPS: choose protected


The EPS functional state of a board selected in the board view is displayed at the bottom of the view as
shown in the following figures.

Figure 124.

EPS functional state from protected active board view

Figure 125.

EPS functional state from protecting active board view

12.3 Configuration: revertive and WTR for EPS


This functionality configures Revertive and Wait Time to restore in a protection scheme.
In order to configure, perform the following operations:

Select a transmission board in the Equipment view.

Select the EPS pull down menu. Then select the Configure.

Figure 126.

Configure EPS

The following dialogue box is opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

153/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 127.

EPS Management dialogue box

The dialog box provides configuration for elements such as:

The name of the protecting element as a label

The Equipment Type (board) of the protecting element as a label

A list displaying the protected elements owned by the scheme

The Revertive Mode flag as an option menu. The available values are revertive and non revertive

The wait time to restore time value (steps of 30 seconds, from 60 to 600). Only for N+1 EPS.
Notes: in the current release the Wait Time to Restore is fixed to 5 minutes.

For this NE:

1+1 ATM MATRIX 4x4 is Not Revertive only

1+1 ATM MATRIX 8x8 is Not Revertive only

1+1 PR_EA is Not Revertive only

1+1 ES-16 is Not Revertive only

1+1 COMPACT ADM is Not Revertive only

N+1 63 x 2 Mbit/s (P63E1 or P63E1N) protection is Revertive

N+1 3x34/45 Mbit/s (P3E3/T3) protection is Revertive

N+1 4xSTM-1 ELECTRICAL port (P4ES1N) protection is Revertive

When the configuration of the equipment protection scheme is completed confirm closing the dialog box by
clicking on the OK push button. The Cancel push button cancels the configuration and closes the dialog box.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

154/396

12.4 Switching EPS


This functionality enables to force a protecting board to work even if there is not failure.
The forced switch will fail if the other board is already forced switched or if the protecting board has a failure
condition.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In order to switch an EPS, perform the following operations:

Select a transmission board in the Equipment view.

Select the EPS pull down menu. Then select the Switch.

Figure 128.

Switching EPS

The following dialogue box is opened.

Figure 129.

EPS Switch dialogue box

This dialogue box displays in its left part the EPS of the selected board.
From this dialogue box the operator can configure, in the current release, only the Lockout options, by
clicking on the relevant radio button.
The Manual to command perform the "manual" switch, active only if the other board is not alarmed.
Clicking on the OK push button will initiate the switch and close the dialogue box. The Cancel push button
cancels the operation and closes the dialogue box.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

155/396

12.5 EPS Overview


EPS Overview allows displaying as well as search for EPS states.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Selecting the EPS Overview option from the Configuration pull down menu Figure below. Opens:

Figure 130.

EPS overview

To Search the EPS groups two different ways of filtering are supported; a filtering for all protection units
located on a dedicated Board Type as well as a filtering for protection units carrying a specific Status.
The search criteria can be chosen with the help of a combo box:
- Board Type: allows filtering for the EPS protected boards; the following filters values should be offered
(examples)

ED

1+1 ATM MATRIX 4x4 is Not Revertive only

1+1 ATM MATRIX 8x8 is Not Revertive only

1+1 PR_EA is Not Revertive only

1+1 ES16 is Not Revertive only

1+1 COMPACT ADM is Not Revertive only

N+1 63 x 2 Mbit/s (P63E1 or P63E1NM4) protection is Revertive

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

156/396

N+1 3x34/45 Mbit/s (P3E3/T3) protection is Revertive

N+1 4x STM1 ELECTRICAL port (P4ES1N) protection is Revertive

N+1 16x STM1 ELECTRICAL port (P16S14E) protection is Revertive

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- Status: allows filtering for all possible EPS protection states; the following values should be offered
(examples):

Ignore

Normal

DNR

Auto-Fail

Auto-WTR

Manual

Lockout

After the filter selection click on Search button to start; the field below the Search button will be updated
(see Figure below.)

Figure 131.

ED

03

EPS overview after Search (Example)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

157/396

Each protection unit is presented with the following information:


-

Protection Group (example protection Groupld, 15)

Board Id (example r01sr1/board#15)

Board Role:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Ped

(Protected)

Ping

(Protecting)

B Status (board status)

(Active)

(Standby)

(Faulty)

Protection Status: defines the current state of the protection unit follow

Normal

DNR

(Do Not Revert)

Auto-Fail

(Auto switch Equipment Fail)

Auto-WTR

(Auto switch Wait Time to Restore)

Manual

(Manual switch)

Force

(Force switch, not supported in current release)

Lockout

The colors used for each row have the following meaning:
-

Green (OK): for protected protection units active

- Red (Critical): for protected protection units in fail condition, protection unit in lockout or active on auto
switch or commands
- Orange (Major): for protected units in standby after a command and protecting protection unit in standby
for auto switch or commands
- Cyan (Indicative) for protecting protection unit active and no fail condition present in the schema (Do Not
Revert State)
At the button of the EPS Overview windows are available five buttons that allows navigating through the
EPS management views and subrack view, board view. In this way the operator has a quick link towards the
views showing the correlation between the alarms and the protection states.
N.B.

Before to click on one of the five buttons select a row

The buttons available are:


- Open Subrack View: opens the Subrack view showing the protection states with icons on the boards
(see Figure below.)
The possible protection states and the relevant symbols are explained in the following:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

158/396

Symbol

EPS protection status


No Request
Do not Revert
Lockout

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Auto Switch (WTR, Fail)


Manual
-

Open Board View: opens the board view showing the alarm and the board administrative states

Open Commands: opens the EPS Switch dialog box, and the relevant description.

EPS Management: opens the EPS Management dialog box, and the relevant description.

EPS Parameters: opens the EPS Configuration dialog box, and the relevant description.

Clock on Close button to exit from the EPS Overview window

Figure 132.

ED

03

Subrack view after Open Subrack View command

SC.3: NE MANAGEMENT
3AL 98253 ADAA

159/396

Figure 133.

ED

03
Board view after Open Board View command

SC.3: NE MANAGEMENT

3AL 98253 ADAA

160/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

13 Multiplex Section Protection Management


13.1 Architecture types

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Multiplex Section Protection in the connection between two NEs protected by cable and port duplication.
At the source the signal is duplicated and sent to the sink via two independent cables. When occurs a
multiplex section failure, the system switches to the other cable and port.
The MS Linear Trail Protection can be applied to any NE where it is possible to configure a linear APS
(single ended/dual ended) line protection. For this NE is applicable the APS 1+1 Proprietary, m the APS 1+1
Standard and the APS 1:1 Standard dual ended.
The APS 1+1 (not revertive) feature permits a 1+1 protection in a linear link, where a path signal is protected
by another dedicated path carrying the same signal. The protection can be set both in single (unidirectional)
and in dual (bidirectional) ended mode.
In single ended mode (unidirectional) the protection is accomplished by switching only the signal affected
by the failure.
In dual ended mode (bidirectional) the protection is accomplished by switching both the affected and the
unaffected signals.
Architecture 1+1 or N+1 Standard
Described in ITU-T Rec. G783/G841. The reference switching criteria are SF and SD. It provides a
k1/k2 communication protocol thus this protection can be single or dual ended.
Architecture 1+1 Proprietary (not used)
The reference switching criteria are SF and SD. No k1/k2 communication protocol is provided thus
this protection can be only single ended.
Architecture 1+1 Optimized (not used)
Architecture 1 : 1 Standard (not used)
Described in ITU-T Rec. G.783/G841 as architecture 1 : n (with n=1). The reference switching
criteria are SF and SD. It provides revertive mode managed by k1/k2 protocol and thus this
protection can be single or dual ended. The spare interface can be used to transport "low priority
traffic".
The WTR time is used with revertive mode.
Signal Degrade (SD) software setting enables the MSP protection mechanisms when a SD is recognized on
the working port. The SD threshold reference values depend on the NE selected threshold on the MS
termination point.

13.2 MSP Options Introduction


All the MSP options are available starting from the Port View following the step explained below:
-

Select Equipment from the Views menu

Double click on the SDH optical board to configure to open the port icon

Double click on the port icon to open the port view

- Select the MSP block in the port view and then choose the MSP options by clicking on Port -> MSP
menu; the possible choice are:

ED

MSP Create
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

161/396

MSP Management

MSP Commands

MSP Delete

MSP Create, MSP Management, MSP Commands and MSP Delete can also be accessed from the
Transmission-> MSP menu

13.3 MSP Create

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the MSP Create option from the Port -> MSP menu (see Figure below.) to open the MSP Schema
Creation.

Figure 134.

Figure 135.
ED

03

MSP Create Option

MSP Schema Creation

SC.3: NE MANAGEMENT
3AL 98253 ADAA

162/396

In this release two MSP Protection Schemas are supported:


-

MSP 1+1 standard

MSP N: 1 standard

Select one and then click on Add Port button in the Ports field to create a MSP schema.
Figure below. Is opened

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Following steps are necessary:


-

Choose Port

Select a Port Role (protected or protecting)

Define Channel Id (mandatory for MSP N: 1)

Define SDH Priority (type of traffic, High or Low)

Figure 136.

MSP schema creation Port dialog

Select the Choose Port button to define the "Protected Port" and "Protecting Port" units.
Figure below is opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

163/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 137.

TP Search

Click on Rack-Subrack and select the Board (Protected/Protecting) on the "Equipment" window (left side).
The "termination Points" list (right side) is available.
On this right side select the OpS TP of the chosen board and then click on the OK button. It is possible to
select the board through the "Board History" button selecting the board list menu.
The "Filter Section" is divided into different fields. It permits to visualize a reduced TP Class. If used, OpS
class must be selected. The complete TP research description is reported in the "Transmission View".
Click on the OK button and repeat the operation for both Protected Port" and "Protecting Port". If it has been
selected a Protected/Protecting port configured in a previously MSP schema protection an error message of
access denied will be appear on the screen.
In the dialogue of Figure below. Also configure the MSP protection schema with the chosen Protection
Schema and enter the related Schema Parameters according the following rules:

ED

1+1 Standard can be dual-ended or single-ended, No revertive

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

164/396

N+1 Standard can be only dual-ended Revertive.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

At the end click on the OK button to confirm the MSP protection schema configuration. An error message will
be appear if the NE does not support the selected schema

Figure 138.

MSP 1+1 standard protection schema (example)

13.4 MSP Management


Select the MSP Management option from the Port -> MSP menu (see Figure below) to open the MSP
Schema Configuration.

Figure 139.

MSP Management Option

The MSP Schema Configuration dialog shows the current state of the MSP schema, setting and state
(protected or protecting) of the current SDH-n port.
This dialog allows setting the configuration parameters for the designated multiplex section:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

165/396

Protection Schema reported in the previous paragraph Architecture Types

Schema Parameters:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Dual Ended / Single Ended protection switch and directionality.

Revertive/Non Revertive mode

The WTR Time (Wait to Restore) is the delay time for switching protection and protecting port after
recovery from failure / defect.

Enable Switch on SD is not operative in current release.

Ports area display the current MSP schema:

Port Id: identify the location of the board

Role: identify the role of the board ("Protecting" or "Protected")

Channel Id: mandatory for MSP N:1 (max. value is 14)

Priority: type of traffic, High or Low

Configure the MSP protection Schema with the chosen protection schema and enter the related schema
parameters. At the end click on the OK button to configure the MSP protection schema. An error message
will be appear if the selected schema in not supported by the NE.

Figure 140.

MSP Management View

13.4.1 MSP modification


The same MSP Management option can be used to modify the schema parameters of an active MSP
configuration.
Before changing a single ended (unidirectional) schema into a dual ended (bidirectional), all active switches
must be cleared (manual switch, lockout,). If the operator wants to change the protection schema
architecture or the ports involved in the MSP schema, the current schema must be removed and re-created.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

166/396

13.5 MSP Delete

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the MSP Delete option from the Port->MSP menu (see Figure below.) to open the "MSP Schema
Deletion".

Figure 141.

Figure 142.

MSP Delete option

MSP Schema Deletion

Click on "OK" button to delete the selected MSP Schema Configuration

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

167/396

13.6 Display of Protection State


The MSP protection state of a port is displayed at the bottom of the Port view. Some examples are reported
in Figure below.
The following states are always displayed:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Port Status - Active (red color) or Standby (orange color). The active protection status is referred to
a protected/protecting port (where the traffic is transported): when a failure is detected, the protecting
port is ready to save the traffic (and becomes active). The standby protection status is referred to a
protecting/protected port that is ready to save the traffic.
MSP Group Status, MSP Own Unit and MSP Related Unit - (green color) Displayed if an automatic switch
is requested. "Own Unit" stands for the currently displayed unit in the port view; "Related Unit" stands for the
related unit of the same protection group. The status indications are:
NR: (abbreviation of No Request); normal, idle condition, the traffic is on the main port
DNR: (abbreviation of Do Not Revert); the SF or SD has been recovered but the traffic is switched on
the spare port
PF: a protection failure has been detected on the port
RF: a release command has been failed
FOP: a failure of protocol has been detected
Complete: = the bridge/switch actions are completed
Pending: = the bridge/switch actions are pending
The "complete" and "pending" indications precede the following statuses:
AS: automatic protection switching enabled
MS: a manual local protection command has been activated
FS: a forced local protection command has been activated
LO: a lockout local protection command has been activated
SF/SD: Signal Failure or Signal Degraded has been detected
WTR: wait time to restore status
MSP Request Source - (green color) indicates where the operator commands (force/manual/lockout) have
been performed. Only present when a command is operative.
- Local: switch due to near end SD/SF or local user switch command
- Remote: switch due to received K1/K2 bytes.
A remote switch cannot be released locally, but can be overwritten by a switch with higher priority.
MSP Protocol Status
This parameter indicates the current APS Protocol status.
The following values are possible:
- OK
- Failure (in case of FOP)

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

168/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 143.

MSP Protection Status Examples

Figure up. Represent a MSP configuration with a normal condition, with an automatic protection switching
and with a forced command. In any situation are represent the statuses displayed on both
protected/protecting Port views. The Active status indication, with a forced command on the protecting group,
shows where the forced command is applied.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

169/396

13.7 MSP Commands

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the MSP Commands option from the Port -> MSP menu (see Figure below) to open the "MSP
Command window".

Figure 144.

MSP Commands option

Protecting Port: the location of the board hosting the protecting port is displayed.
Protected Port: the location of the board hosting the protected port is displayed.
The lockout of protection command denies working channel access to the protection section by issuing a
"Lockout" of protection request (on the "Protection Status" of MSP Management). It is possible to "Lockout
the Protecting Port" or "Lockout the Protected Port"; to remove the lockout commands select Release Ping
(for the protecting) and Release Ped (for the protected).
The Force to command switches the working channel (Protected port) to the protection section (Protecting
port), unless an equal or higher priority switch command is in effect or SF condition exits on the protection
section, by issuing a "Forced" switch request for that port (on the "Protection Status" of MSP Management).
It is also possible to switch back to the working channel using again the "Forced to" Protected port command.
For 1+1 non-revertive system, forced switch no working channel transfer the working channel back from
protection to working section, unless an equal or higher priority request is in effect. Since forced switch has
higher priority than SF or SD on working section, this command will be carried out regardless of the working
section condition.
The Manual to command switches the working channel (Protection port) to the protection section (Protection
port), unless a failure condition exits on the protection section or an equal or higher priority switch command
is in effect, by issuing a "Manual" switch request for that port (on the "Protection Status)" of MSP
Management). Is also possible to switch back to the working channel using again the "Manual to" Protected
port command.
For 1+1 non-revertive system, manual switch no working channel transfers the working channel back from
protection to working section, unless an equal or higher priority request is in effect. Since manual switch has
lower priority than SF or SD on working section, this command will be carried out only if the working section
is not in SF or SD condition
The Clear WTR command cancels the delay time for switching protection and protecting port after recovery
from failure/defect.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

170/396

The Exercise command issues an exercise request for protection channel and checks response on MSP
bytes, unless the protection channel is in use. This check controls the k1/k2 communication protocol
functionality to be sure that the protocol is right also on the protection section.
Not operative in current release.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Release command clears all previously switching commands.\

Figure 145.

MSP Commands

The priority levels for the MSP commands are (from the higher to the lower one)_ Lockout. Force to, Autoswitch (SF&SD), Manual to.
Table 1. Gives the priority rules when are occurred two different commands. The first column on the left and
the first row at the top report the switch protection and the external MSP commands. The row/column
crossing gives the command or protection result (i.e.: if an "Auto-switch" and a "Manual to" command are
present, "Auto-switch" is operative.
Table 1. MSP commands and Auto-switch protection priority
Lockout of
Protection

Forced to

Auto--switch

Manual to

Lockout

Lockout

Lockout

Forced

Forced

Lockout of
Protection
Forced to

______________

Auto--switch

Lockout

Forced

Manual to

Lockout

Forced

ED

Lockout

03

______________

______________
Auto--switch

Auto--switch

______________

SC.3: NE MANAGEMENT
3AL 98253 ADAA

171/396

13.8 MSP overview


MSP Overview allows displaying as well as search for MSP states.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Selecting the MSP Overview option from the Configuration pull down menu Figure below opens.

Figure 146.

MSP overview

To Search the MSP groups two different ways of filtering are supported; a filtering foe all protection units
located on a dedicated Board Type as well as a filtering for protection units carrying a specific Status.
The search criteria can be chosen with the help of a combo box:
- Board Type: allows filtering for the MSP protected boards; the following filters values should be offered
(example):

ED

Ignore

P4ES1N

P4S1N

P4E4N

P4S4N

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

172/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

P16S1N

S-41N

L-41N

L-42N

S-161

S-161N

S-161ND

L-161

L-161N

L-161ND

L-162

L-162N

L-162ND

SYNTH16

SYNTH16N

- Status: allows to filter for all possible EPS protection states; the following filters values should be offered
(example):

Ignore

NR (Normal)

DNR

Auto-SF

Auto-SD

Auto-WTR

Manual

Force

Lockout

APS Invalid (Fail)

Bad channel (Fail)

After the filter selection click on Search button to start; the field below the Search button will be update (see
Figure below.)

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

173/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 147.

MSP overview after Search (Example)

Each protection unit is presented with the following information:


-

Protection Group (example protection Groupld, 160)

Port Id (example r01sr1sl9/port#01-OpS)

Role:

Ped

Protected

Ping

Protecting

Status (board status):

(Active)

(Standby)

(Faulty)

ET

Extra Traffic (Not operative)

Protection Status: defines the current state of the protection unit as follow

ED

NR

(Normal)

DNR

(Do Not Revert)

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

174/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Auto-SF

(AutoSwitch Signal Degrade)

Auto-SD

(AutoSwitch Signal Degrade)

Auto-WTR

(AutoSwitch Wait Time To Restore)

Manual

(Manual Switch)

Force

Lockout

APS Invalid

Bad channel

(Protection fail condition APS invalid)


(Protection fail condition Channel Mismatch)

The colors used for each row have the following meaning:
-

Green (OK): for protected protection units active

- Red (Critical): for protected protection units in fail condition, protection unit in lockout or active on
autoswitch on commands
- Orange (Major) for protected units in standby after a command and protecting protection unit in standby
for autoswitch or commands
- Cyan (Indicative: for protecting protection unit active and no fail condition present in the schema (Do Not
Revert State)
At the bottom of the MSP Overview windows are available five buttons that allows to navigate through the
MSP management views and to open the Port View.
By clicking on Open Port View the operator has a quick link towards the view showing the correlation
between the alarms and the protection states.
N.B.

Before to click on one of the five buttons select a row

The buttons available are:


- Open Port view: opens the port view showing the correlation between the alarm and the MSP protection
states. (See Figure below)
-

MSP Create: opens the MSP Create dialog box.

MSP Delete: opens the MSP Delete dialog box

MSP Management: opens the MSP Management dialog box

MSP Commands: opens the MSP Commands dialog box

Click on Close button to exit from the MSP Overview window

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

175/396

Figure 148.

ED

03
Port view after Open Port View commands

SC.3: NE MANAGEMENT

3AL 98253 ADAA

176/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

14 TRANSMISSION VIEW
14.1 Overview
This section describes the operations necessary for the consultation, modification and configuration of TPs,
providing a representation of the entire signal flow.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The generic Transmission View, described in this chapter, offers the possibility of displaying a single TP or
a set of all kinds of TPs (or collected functionality which is represented by one/several TPs).
To display the termination points in the Transmission View, either select specific TPs from a TP search
dialog or access the view directly from another view, e.g. by navigating from the Port View.
The Transmission View provides the following features:

Brief overview regarding transmission resources.


An overview concerning all TPs belonging to a port can be called in by activating the function to
expand the selected TP. TP names are listed in an additional information area if the mouse
pointer is positioned over it. The following states are indicated:
- The alarm synthesis icon indicates the alarm state
- A cross indicates the cross-connection state
- A circle indicates whether a TP can be structured
- Whether a TP is under Performance Monitoring indicated by a blue "P" letter
- Whether a TP is involved in a loop action, an arrow indicates it

An overview concerning signal flow can be requested by a user action. The user can select a TP and
apply the action Show Cross-connected TPs. The result is that the objects related to the TP are
displayed and lines indicate the connections. Expanding and hiding TPs that are related to the
currently selected TP (e.g. show all TPs that are above the TU-12 CTP) enables all related TPs to be
added to the view, thus providing a representation of the entire signal flow.

Display of single or multiple termination points.


Search for and select a termination point in a TP search dialog and display it in the Transmission
View.
Pop-up the Transmission View from the board view. All TPs/compound TPs associated with the
physical port are displayed (i.e. TPs down to AU-4).

ED

Provide the functionality to create/show cross-connections.

Provide the functionality to create/show Multiplex Section Protection (Not operative in the current
release)

Provide the functionality to create/show Loopback commands.

Provide the possibility of configuring a selected TP. Calling the configuration dialogs of the common
Transmission/Port Views category accesses this functionality.

Provide the possibility of showing a detailed view of a TP with alarms, navigating to the Port view.

Provide the possibility of showing and setting Performance Monitoring parameters and data.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

177/396

14.2 View elements

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Transmission View uses the symbols illustrated in Figure below.

Figure 149.

Symbols Used in Transmission View

14.3 View Layout


The Transmission View is a main view. It provides views of specific areas, which display the transmission
resources, and the specific Transmission View pull down menu, which provides the Transmission View
operations.
14.3.1 View Description
Figure below. Illustrates the Transmission View area. TPs that are received from the network element are
displayed in the Transmission View with the respective TP and connection symbols described in The number
of TPs presented initially depends on whether the Transmission View is popped up from a board view,
whether a TP has been selected in another view or whether it is called without a selected TP.
When the "Transmission view" is reached selecting the Transmission option in the View pull down menu in
its initial state contains no objects.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

178/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 150.

Transmission View Area

14.3.2 Number of TPs Displayed in Transmission View


It is possible both to expand a VC-4, thus displaying all underlying TPs, and to hide TPs, which are of no
interest. The objects initially displayed depend on the situation/definition.
14.3.3 Naming TPs
The following rules are applied in order to identify the TPs displayed:

ED

The root node contains the full user label,

All child nodes contain a short label indicating the position inside the tree.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

179/396

14.3.4 Dynamic View Behaviour


The following section describes the view states and provides a short description of events that affect the
view.
Initial state of the view
In its initial state, the Transmission View contains no objects. Objects can be searched for and displayed
using the Add TP dialog.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Working state of the view


In its working state, the Transmission View already contains objects. If the operator searches for and
displays a TP using the TP Search dialog, the view is first initialized again and then the TP is displayed. The
same applies in the case of navigation from another view to the Transmission View - the Transmission View
is always initialized and the corresponding objects are then displayed in it.
Navigation to Transmission View from other views
If the Transmission View is popped up from the Port View, only the selected TP is displayed.
Alarm notification
The alarm synthesis icons of the TP objects indicate alarms concerning the TPs displayed graphically. The
TP objects are updated accordingly.
Object deletion
The TP objects indicate all kinds of object deletion events related to TPs displayed. The graphical objects
are removed accordingly from the Transmission View. Example: modification of the payload structure from
63 TU-12 to 3 TU-3.

14.4 Transmission view access and menu


The "Transmission view" can be reached selecting the Transmission option in the View pull down menu. In
this case, in its initial state, the Transmission View contains no objects.
In the case of navigation from another view (example the "Port view") to the Transmission View, the
Transmission View is always initialized and the corresponding objects are then displayed in it.
Selecting the "Transmission" option in the menu bar the complete pull down Transmission menu is
presented
The following menu items are available:

ED

Add TP

Select the TP to show on the Transmission view.

Expand

Display TPs that are related to the selected TP.

Hide

Hide TPs that are related to the selected TP or the selected TP.

TP Configuration

Set parameters for the Overhead on Synchronous TP's.

TP Frame Mode Configuration


management

TP Threshold Configuration

Set B2 ExBER and Degraded Signal parameters.

Terminate TP

Terminate a path on a AU-4 CTP

Disterminate TP

Disterminate a path on a AU-4 CTP

AU4 Concatenation

Cross-Connection
03

Set parameters for 2Mbit/s G.703/G.704 or ISDN-PRA

Manage the connection of the paths.

SC.3: NE MANAGEMENT
3AL 98253 ADAA

180/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Monitoring Operations

Create, configure and delete POM/SUT and TC TP's.

Performance

Set and show Performance Monitoring parameters and data.

Structure TPs
TP

Provides the possibility of structuring and destructuring selected

Loopback
maintenance purposes

Manage

Physical Media

Manage the physical TP setting.

MSP
Manage the Multiplex Section Protection of the NE. Not available
for PDH port. See MSP Management. In this paragraph is not described the MSP>NE MSP
synthesis option of the Transmission menu, not used in this NE.

Show Supported Board


Navigate to Port View

the

loopback

commands,

for

commissioning

or

Navigate to the upper board level.


Permit to show the detailed alarm of the TP.

These options are described in next paragraphs except the previously referenced.

Figure 151.

Transmission menu options

14.5 Add TP
Select the Transmission -> Add TP option.
This menu item opens the TP Search dialog. The TP Search dialog enables the user to search for and add a
TP to the Transmission View (e.g. search for all TPs on a board with PM enabled).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

181/396

14.5.1 TP Search
Default Mode

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In this mode, the dialog displays the structure of the equipment tree. After double-clicking, e.g. on a port, the
contents of the port appear on the right-hand side of the dialog (TP list). To keep the number of items
displayed small, they are displayed in a hierarchical order. Double-click again to recall the next level .

Figure 152.

TP Search Dialog, Initial State

After double-clicking on an object, an Information window appears (see). The message text corresponds to
the object selected.

Figure 153.

ED

03

Information Window

SC.3: NE MANAGEMENT
3AL 98253 ADAA

182/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

It is possible to select several individual TPs from the TP list by clicking on them while holding down the Ctrl
key on the keyboard. To select a block of TPs, click on the first TP and then click on the last TP in the block
while holding down the Shift key on the keyboard. But only the first TP selected in the list will be shown in
the Transmission View.

Figure 154.

TP Search Dialog with Various TP Selections

After clicking on Show CC State, a more detailed TP list is displayed containing TP cross connection status
information.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

183/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 155.

TP Search Dialog with Status Information Displayed

The symbols in the TP list have the following significance:

Figure 156.

Symbols in TP Search

The background color of the symbols represents the status of the TP:

Grey = inactive

Green = active

An easy way to recall to previously displayed boards is to use Board History. Select the relevant board from
the list.

Figure 157.

ED

03

Board History Check List

SC.3: NE MANAGEMENT
3AL 98253 ADAA

184/396

Search Mode
Use Search Mode together with the filtering options provided below the TP list. The following options are
available:

Class:
Ignore, E1S, OpS, PPI, AU-4, VC-4, AU-4+VC-4, TU-3, TU-3+VC-3, TU2, TU-12, VC-12,
TU-12+VC12, AUX, MS, RS, OGP, GMAU.

Connection State (Current connectivity status):


Ignore, not connected, connected

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alarm State (Path Trace):


Ignore, critical, major, minor, warning, not alarmed

Assign State:
Ignore, NML, EML

Perf. Monitoring (Performance Monitoring condition):


Ignore, enabled

TTI expect: not used

TTI receive: not used

TTI transmit: not used

Location:
Permits to insert the location of the TP in the following format:
r<rack#>sr<subrack#>sl<slot#><port#>

ED

Name: not supported

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

185/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 158.

TP Search Dialog with Different Filtering Options

After activating the search process with the Search TP button, the following dialog box appears. Clicking on
Cancel can interrupt the search.

Figure 159.

Information... Dialog for Search Process

N.B. When searching for PM-enabled TPs on NE, Rack or Subrack, the time for the request can be very high.
It is recommended to search for PM-enabled TPs at the board level (a board is selected for the search).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

186/396

Common Buttons
The following buttons are available in all modes:
Ok
Closes the dialog and opens the Transmission View containing the selected TP.
Close
Closes the dialog without updating the Transmission View.
Print

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This command is used to generate and print a list of TPs according to the current filter selection.
The command opens the following dialog:

Figure 160.

Print to Printer

Select the desired printer from the list box and click on Ok to start the print job or abort with Cancel.
The dialog changes after clicking on File:

Figure 161.

ED

03

Print to File

SC.3: NE MANAGEMENT
3AL 98253 ADAA

187/396

Enter the name of the output file in the input field or select a file name from the File Select dialog by clicking
on Select file. Select if the output format should be Postscript or ASCII.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The output file is generated after clicking on Ok. Use Cancel to stop the process.

Figure 162.

Example Printout

Help
This command opens the online help for the TP-Search dialog.

14.6 TP Configuration
Select the Transmission -> TP Configuration option.
TP Configuration can also be accessed from the "Port" view menu.
14.6.1 High Order TP Configuration
Depending on the TP selected, a dialog appears for the configuration of the main parameters of the objects.
Example:

VC-4 TTP (140 Mbit/s PDH)

VC-3 TTP (34 and 45 Mbit/s PDH)

Mod VC-4 TTP (matrix resource)

The main parameters are:

C2 Signal Label: "Automatic" (decided by the NE) or "Equipped not specific".

J1 Path Trace.

The dialogs of the following figure appears:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

188/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 163.

High Order TP Configuration

14.6.1.1 J1 Path Trace


Operative only on VC-4 in current release.
If the Path Trace is 16 bytes long, the first byte is a CRC7 checksum calculated by NE.
If the Path Trace is shorter than 16 bytes, it is filled with zero bytes ("0" hexadecimal).
Received fields are read only.
With the relevant button the operator can set the Expected field as:
- TTI Enable
- TTI Disable
- TTI Repeated
The Transmitted field can be set with TTI Enable or TTI Repeated byte
Empty TTI button permits to send an all zeroes path trace.
To replace modified with the default, enter the default manually according to the following table .
Table 2. Default value for C2/V5 Signal Label

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

189/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

TP

VC-4 TTP / AU4 CTP

VC-4 TTP

VC3-TTP

VC-12 TTP

(SDH)

(PDH)

Significant Byte

C2

C2

C2

V5

Default value

18

Click on Hex button will be opened displaying in hexadecimal code the same value reported in Transmitted
and received field.

Figure 164.

J1 hexadecimal editor (example)

14.6.1.2 C2 Signal Label


Received, Expected and Transmitted fields are read only.
They can display the following number, according the G.707 recommendations for the C2 Signal Label:

0: Unequipped

1: Equipped non-specific

2: TUG structure

3: Locked TU-n

4: Asynchronous 34/45Mbyte

18: Asynchronous 140Mbyte

19: ATM

20: MAN, DQDB

21: FDDI.

In the Transmitted field it is possible to select the values:

ED

Automatic: the NE according the VC structure automatically selects the C2 Signal Label value.

Equipped not specific (it corresponds to number 1)


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

190/396

14.6.2 J0 Section Trace management


Select RST block and then select Port -> TP Configuration

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The fields of the following figure appears:

Figure 165.

J0 Configuration

This function is implemented in order to manage the J0 Trace configuration.


This dialog shows the current values for received, expected and transmitted trail trace and it allows the
operator to change only the values of expected and transmitted trail trace.
The received trail trace is read-only.
Expected and Transmitted fields are editable by the operator.
With the relevant button it is possible to enable or disable TTI Monitoring.
Click on Hex button will be opened displaying in hexadecimal code the same value reported in Transmitted
and received field.
14.6.3 Low Order TP Configuration
Depending on the TP selected, a dialog to configure the main parameters of the following objects:

VC-12 TTP.

The main parameters are:

V5 Signal Label. "Automatic" (decided by the NE) or "Equipped not specific".

J2 Path Trace. Not operative in current release.

The following dialogs appears:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

191/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 166.

Low Order TP Configuration

Click on Hex button will be opened displaying in hexadecimal code the same value reported in Transmitted
and received field.

Figure 167.

ED

03

J2 hexadecimal editor

SC.3: NE MANAGEMENT
3AL 98253 ADAA

192/396

14.6.3.1 J2 Path Trace


Not operative in current release.
If the Path Trace is 16 bytes long, the first byte is a CRC7 checksum calculated by the NE.
If the Path Trace is shorter than 16 bytes, it is filled with zero bytes ("0" hexadecimal).
Expected and Transmitted fields are editable by the operator.
Mode1 enable the 16 bytes long sequence for Path trace

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

One repeated byte allows setting one byte that will be repeated
Received fields are read only.
With the relevant button it is possible to enable or Disable TTI Monitoring.
Empty TTI send an all zeroes path trace.
14.6.3.2 V5 Signal Label
Received, Expected and Transmitted fields are read only.
They can display the following number, according the G.707 recommendations for the V5 Signal Label:

0: Unequipped

1: Equipped non-specific

2: Asynchronous

3: Bit Synchronous

4: Byte Synchronous

In the Transmitted field it is possible to select the values:

Automatic: the NE according the VC structure automatically selects the C2 Signal Label value.

Equipped not specific (it corresponds to number 1)

To replace modified with the default, enter the default manually according to the value reported in Table 2.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

193/396

14.7 TP Frame Mode Configuration


This command is available for:
-

P12

Select the Transmission -> TP Frame Mode Configuration option


TP Frame Mode Configuration can also be accessed from the "Port" and "Synchronization" view menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This menu item enables the configuration of the most important transmission parameters concerning the
Primary Rate Access and G.703/G.704 frame management.
The following dialog appears:

Figure 168.

TP Frame Mode Configuration

The windows contains the following graphical objects:


- "Framed Signal Mode" that allows to configure the attribute framed Signal Mode; the user can choose
one of the following value:

"Not Framed" (G.703 interface): the PRA function cannot be activate;

"Framed without PRA" (G.704): the behavior according to ETS 300-233 is applied in the handling of
bits of Time Slot 0 in terms of state, defect detection and consequent action;

"Framed with PRA" : PRA function are activated

"Framed with leased line PRA" a proprietary leased line behavior is a applied.
"CRC4 Mode" that defines the monitoring capabilities applied to the signal with a CRC multiframe:

ED

"Enabling": enable or disable the CRC-4 error counting

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

194/396

"Remote Indication": red-only field that indicates if status of CRC-4 error counting functionality of farend NE is enabled or disabled

"Frame Status" that reports an indication of the received signal:

"No indication"

"The 2Mb/s signal is multi-frame"

Press OK to apply the parameters or Cancel to close the dialog

14.8 TP Threshold Configuration


All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

This menu allows the operator to set the alarm thresholds for MST and VCi layer.
Select the MST or the VCi block
Select the Transmission -> TP Threshold Configuration option.
Figure below. Will be opened.
The user can select one of the two different Defect distributions:
- Poisson distribution enable configuration of the Excessive Bit Error Ratio (ExBER on MST, VCi)
threshold and of the Signal Degrade (SD on MST, VC) threshold of the TP's related counted primitives.
- Burst distribution enable configuration of the maximum number of error frames and the total a amount
of bad block per frame.
-

ExBER - Threshold: 10-3 to 10-5


Enable Consequent Actions: fixed to enables

Signal Degrade - Threshold: 10-5 to 10-9

Burst Parameters - Threshold: 1 or 10 or 100 or 1000

Burst Parameters - Consecutive Bad Seconds: 2 to 10

Figure 169.

Degraded Signal Threshold selection

Click on OK to confirm the chosen parameters.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

195/396

14.9 Terminate/Disterminate TP
Select the Transmission -> Terminate TP or Disterminate TP option.
Only one command in the menu is available, depending on whether a TP is terminated or not.
14.9.1 Terminate TP
Use this action to terminate a path. It can be performed on a AU-4 CTP.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

A cross-connection between the selected AU-4 CTP (= aTP) and a modifiable VC-4 TTP (= bTP) is created.
Three TUG-3 and TU-3 are created if the modifiable VC-4 TTP was not already structured.
A cross appears in the icon of the terminated TP:

If the TP is already cross-connected a error message appears.


14.9.2 Disterminate TP
Use this action to disterminate a path. It can be performed on a AU-4 CTP. The related cross-connection is
deleted.
NOTE: the Disterminate action is not possible in the
operation/connection/termination on the underlying signals, such as:

Performance Monitoring on lower or higher TPs

POM / HPOM operations

Lower order Connections

Higher order Connections

Lower/Higher order Path Terminations

Loopbacks on lower TPs

case

that

is

still

existing

any

Thus the deletion of every operation/connection/termination is necessary, in the same order as above listed,
before disterminating a TP.
A box message will be presented, in order to confirm the TP distermination.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

196/396

14.10 Monitoring Operations


Select the Transmission -> Monitoring Operations option as for the following figure.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Creation/Deletion and Configuration options are present.

Figure 170.

Monitoring Operations

Monitoring Operations can also be accessed from the "Port" view menu.
The commands of this menu item are for the management of the POM/SUT /TC (Path Overhead
Monitoring, Supervised Unequipped Termination and Tandem Connection).
This command is available for:

AU-4 CTP

TU-3 CTP

TU-12 CTP

14.10.1 Creation/Deletion
The dialog allows multiple object creation/deletion.
The dialog shown in the following Figure below opens

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

197/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 171.

Monitoring Operations Creation/Deletion

The Path Overhead Monitoring has the following parameters:

Before Matrix (available only on AU-4 CTP)

After Matrix

The Supervisory Unequipped Termination, not operative in current release, has the following parameters:

Sink (before matrix)

Sink (after matrix)

Source

Bidirectional

The Tandem Connection has the following configurable parameters:

Tandem Connections Monitoring (TCM):


-

TCM Before Matrix

TCM After Matrix

Tandem Connection Termination (TCT):


-

TCT Bidirectional Before Matrix

TCT Bidirectional After Matrix

Press Ok to apply the parameters or Close to close the dialog and discard the not with Ok applied changes.
When select and apply the Path Overhead Monitoring, the changes will be displayed in the Port View in the
following manner:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

198/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 172.

Display of POM and TCM in Port View (example)

When select and apply the Tandem Connection Monitoring / Tandem Connection Termination, the changes
will be displayed in the Port View in the following manner:

Figure 173.

Display of POM and TCM/TCT in Port View (example)

14.10.2 Configuration
Depending on the parameters selected in the Monitoring Operations Creation/Deletion dialog, not all
sections of the dialog are available.
N.B. It is possible to open the POM and TCT/TCM Configuration dialog for a CTP even if neither Path
Overhead Monitor nor Tandem Connection was created before (SUT isn't available in this release). No
changes can be made in this case and the values displayed can be ignored.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

199/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 174.

Monitor Configuration

TTI Definition
The TTI (Trail Trace Identifier) has a maximum length of 16 characters.
The following TTI Definitions are available:

TTI Expected

TTI Received without the display

TTI Sent

The following TTI Types are available:

TTI Enabled

TTI Disabled

TTI Repeated Byte

Error Distribution
Poisson and Burst error distribution are supported
TCM/TCT Cons Actions
It is needed to support explicit consequent action activation (AIS insertion) for TCT sink and bidirectional.
Thresholds
Set the thresholds of the following parameters:
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

200/396

Signal Degrade
Poisson mode only: from 10-5 to 10-9.

Excessive Error
Poisson mode only: from 10-3 also if presented a selection from 10-3 to 10-5

Burst Degrade
Select a value between 1 and 1000 errors/sec for the Burst Degrade threshold.

Burst Consecutive

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select a value between 2 and 10 sec for the Burst Degrade Consecutive.
Alarm Timing
Rising and Clearing Timing are not supported by OMSN.
Unequipped Trail
Not available

14.11 Structure TPs


Select the Transmission -> Structure TPs option.

Figure 175.

Structure TPs option

This menu item provides the possibility of structuring and destructuring a selected TP. The level that is
selected defines how the signal is to be structured, e.g. if a VC-4 TTP is selected and the menu item TU-12
is chosen, the signal is structured down to 63 TU-12 CTPs. The following menu items represent all those
possible:
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

201/396

TU-2. Not supported.

TU-3.

TU-12.

VC-3/VC-4. Not supported.

VC-12. Not supported.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following items are available for synchronous TPs:

Modifiable VC-4 TTP: TU-3, TU-12

TUG-3: TU-3, TU-12

TUG-2: TU-12.

14.12 Loopback
The commands of this menu item are for the management of the loopback commands, for commissioning or
maintenance purposes.
14.12.1 Loopback Configuration
The loopback can be applied at line (external to equipment) level or at internal equipment level. The
loopback commands are used to separate the communication network into independent part checking the
line/equipment functionality during the network installation or maintenance operation.
The loopback architecture provides four configurations.
Line Loopback And Continue
Line Loopback And AIS
Internal Loopback And Continue
Internal Loopback and AIS

Figure 176.
ED

03

Loopback configurations

SC.3: NE MANAGEMENT
3AL 98253 ADAA

202/396

Select a TP that supports the Loopback Configuration


Loopback act on the following TPs:

PDH board (only from the Port View):


- Line loopback performed on:
P for 2/34/45/140 Mbit/s PPI
- Internal loopback performed on:
P12 for 2Mbit/s CTP

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

P31 for 34/45Mbit/s CTP

P4 for 140Mbit/s CTP

SDH board:

The loopback configuration can be done only on SDH ports with the acronym ending with a
"N" letter (i.e. P4S1N, S-4.1N, L-4.1N, L-4.2N, etc.)
- Line loopback performed on:
EIS for electrical STM-1 SPI
OpS for optical STM-1, STM-4, STM-16 SPI
- Internal loopback performed on:
MsT TTP for STM-1, STM-4, STM-16 ports
Select the Transmission -> Loopback -> Port Loopback Configuration option.
Port Loopback Configuration can also be accessed from the "Port" view menu.

Figure 177.
ED

03

Port Loopback Configuration

SC.3: NE MANAGEMENT
3AL 98253 ADAA

203/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure below. Opens.

Figure 178.

Port Loopbacks View

Choose the TP clicking on the "Choose TP" button. Select the TP where to apply the loopback command.
For this NE the "Timed Loopbacks" field is not managed and thus Start/Stop loopbacks time is not editable.
14.12.2 Loopback Management
To manage the loopback configuration select the Transmission -> Loopback -> Loopback Management
option.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

204/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 179.

Loopback Management view

Loopback Management can also be accessed from the "Port" view menu and from the "Configuration
menu
Figure below. Opens.

Figure 180.
ED

03

Loopback Management

SC.3: NE MANAGEMENT
3AL 98253 ADAA

205/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The configured loopback are listed into the current loopback table. This table can be managed by the
"Search" criteria, "Delete" and "Create" commands.

Search Criteria (operative): to configure the filter select the "Loop and Continue" type (Yes= Loop
And Continue, No= Loop And AIS) then select the "Directionality" Internal or Line and edit the Initial
TP Id (write: rack, subrack, board, port# and the TP type: EIS (SPI/PPI Electrical), OpS (SPI/PPI
Optical), MST and so on. For "Initial TP" has to be intended the outgoing signal while for "Destination
TP" the incoming signal. Enable the filter through the "Toggle Filter" Enable/Disable button. Click on
the "Search" button to start the configured loopback research into the current loopback table.

The "Delete" command permits to delete a loopback listed in the Current loopbacks Table: select a
loopback in the list and click on the "Delete" button.

The "Create" command permits to create a new loopback configuration: clicking on "Create" the
previous figure opens. Follow the previously paragraph indications to create a new loopback
configuration.

The activated loopbacks are signaled in the Port view and in the Transmission view as for the following
figures:

Figure 181.

Figure 182.

ED

03

Loopback Port View

Loopback Transmission View

SC.3: NE MANAGEMENT
3AL 98253 ADAA

206/396

14.13 Physical Media

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Transmission -> Physical Media option.

Figure 183.

Physical Media options

The Physical Media options permit to set physical configuration of each TP.
It opens a menu in which the various options will be available according the TP's type (for the option
common with the "Port view" reference is made to the relevant paragraph):
- ALS Management.
- Show Optical Configuration.
- TX Quality Configuration.
- Single Fiber Configuration.
- Extra traffic Not operative
- Regeneration Section management Not operative
- Line Length Configuration.
- Set Domain.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

207/396

- HDSL Configuration Not operative


- NT Configuration Not operative
- X21 Configuration Not operative
14.13.1 Set Domain
This option is referred to the Security management and allows the user to set the Manager list and the
Access Control Domain of the selected TP.
Select the block: EIS for Electrical SDH port, OpS for Optical SDH port, P (PPI) for PDH port.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Set Domain option from the Physical Media cascade menu to present the following view:
The dialog-box contains the following fields:

NML Assignment: each connected manager to the TP is highlighted in the list. The user can set a
manager clicking on the denomination.
Several managers can be enabled contemporaneously, having in charge the TP.
The Manager List contains the list of managers ( i.e. RM, SY, NPOS , EML) that work on the NE.
The EML-USM administrator (SH or Craft Terminal) should set the Manager List only to remove a
manager in case of emergency (i.e. the Manager misses the NE connection).

Resource domain field allow selecting the domain among that displayed in the list, assigning it to
the TP.
The different domains could be assigned to different operators.

OK button is used to validate the selection.


Cancel button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

Figure 184.

ED

03

Set Domain

SC.3: NE MANAGEMENT
3AL 98253 ADAA

208/396

14.14 Navigation Commands


14.14.1 Expand

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Transmission -> Expand option.

Figure 185.

Expand option

This menu item provides the possibility of displaying TPs that are related to the selected TP. These may be
TPs that are contained by the TP or TPs, which belong to the physical port that is actually connected to the
TP.

Show next level of lower TPs,

Show all lower TPs,

Show next level of upper TPs,

Show all upper TPs.

14.14.2 Hide
Select the Transmission -> Hide option.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

209/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 186.

Hide option

This menu item provides the possibility of hiding all upper/lower TPs of a selected TP and the deletion of a
selected TP.

Lower TPs,

Upper TPs,

Selected TPs.

14.14.3 Show Supported Board


Select the Transmission -> Show Supported Board option.
This menu provides the possibility of navigating directly to the board that supports the TP.
The Board View appears.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

210/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 187.

Board View

14.14.4 Navigate to Port View


Select the Transmission -> Navigate to Port View option.
This menu provides the possibility of navigating to the corresponding Port View related to the selected TP in
order to access a detailed overview of alarms quickly.
The Port View appears.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

211/396

Figure 188.

ED

03
Port View

SC.3: NE MANAGEMENT

3AL 98253 ADAA

212/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

14.14.5 Navigate to HOA Port


After selected a structured VC or TU, then click on Transmission > Navigate to Port View option.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The HOA port displays the internal structure of the payload, as for the following figure:

Figure 189.

ED

03

Navigate to HOA Port

SC.3: NE MANAGEMENT
3AL 98253 ADAA

213/396

15 Cross-Connection Management
15.1 Introduction
15.1.1 Overview
The purpose of this domain is to manage the connection of the high and low level path.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following chapters provide the user with information concerning operations on cross-connections:

"Multiplex Structures for SDH" gives an overview on the SDH technology

"Definition of Termination Points" gives an overview about the termination points implemented on the
NE

"Cross-Connection Types" provides information concerning cross-connection types supported by the


NE

"Cross-Connection Protection" provides information concerning cross-connection protection


supported by the NE

"Operative sequence to execute Cross-Connections" details the complete procedure to realize


cross-connection

"Cross-Connections Management" details the contents of the main cross-connections view

"Create/Modify Cross-Connections" describes the creation and modification of cross-connections

"Activate/Deactivate/Delete Cross-Connections" describes the activation, deactivation and deletion


of cross-connections. Activation and deactivation not supported in current release.

"Split and Join Cross-Connections" describes how to split or join bidirectional cross-connections. Not
supported in current release.

"Protection Switching" deals with switching actions (force, manual, lockout protection) on crossconnections

"Print" deals with printing out list entries on printers or into files

"Port Switch Over" not operative.

"Show Cross-Connected TPs" describes the possibility of showing connections between two or more
TPs of different hierarchies, e.g. connection between AU4 and VC4.

15.1.2 Multiplex Structures for SDH


By introducing the Synchronous Digital Hierarchy (SDH), a standardized transmission has been created,
matching the European with the American standard. The SDH signal structure contains an extended
overhead as well as a fixed pointer controlled assignment of the user signal elements, thus improving the
possibilities of the network management.
Synchronous multiplexers into Virtual Containers (VC) pack signals of the Synchronous and Plesiochronous
Digital Hierarchy (PDH). The STM-1 signal structure is achieved by using the multiplex structure complying
with ITU-T and ETSI. Each of the user channels (2 Mbit/s, 34 Mbit/s, 45 Mbit/s and 140 Mbit/s) is packed into
a container synchronous to the STM-1 frame according to a predefined structure.
To adjust the plesiochronous signals to the synchronous network clock, certain filling algorithms are
available. Fix fill bits are inserted into synchronous signals. A byte column (9 Byte) as Path Overhead (POH)
is added to the Container (C) generated. Path Overhead and Container together form the Virtual Container
(VC). With the pointer pointing to the start of the VC, in respect of the STM-1 frame, an Administrative Unit
(AU) or - if several Containers of a group are to be combined - a Tributary Unit (TU) is generated. Several
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

214/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

TUs form a Tributary Unit Group (TUG) and TUGs again can be combined into a VC. The AU of the signal,
together with the Section Overhead (SOH), finally makes up the STM-1 frame.

Figure 190.

SDH Multiplex Structure according to ITU-T G.709

The STM-1 frame consists of:

ED

A Section Overhead (SOH)

An AU Pointer area

A payload area

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

215/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 191.

Frame Construction within the Synchronous Digital Hierarchy

The STM-1 frame has a basic bit rate of 155.520 Mbit/s. A single user channel is packed into a Virtual
Container. These Virtual Containers are of different size and may be nested or packed differently.
Virtual Containers for the European bit rates:

The STM-1 frame contains a VC-4,

A VC-4 may contain one C-4 or three TUG-3,

Each TUG-3 may contain one VC-3 or seven TUG-2,

Each TUG-2 contains three VC-12 or one VC-2.

An STM-1 user signal can be constructed of:

ED

Either 1 x VC-4

Or 3 x VC-3

Or 2 x VC-3 + 7 x VC-2

Or 2 x VC-3 + 21 x VC-12

Or 1 x VC-3 + 14 x VC-2

Or 1 x VC-3 + 7 x VC-2 + 21 x VC-12

Or 21 x VC-2

Or 14 x VC-2 + 21 x VC-12

Or 7 x VC-2 + 42 x VC-12

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

216/396

Or 63 x VC-12.

STM-N signals are constructed by integer multiples of the basic signal STM-1 of 155.520 Mbit/s. For
example an STM-16 signal of 2.488.320 Mbit/s is generated by combining sixteen STM-1 signals byte
interleaved.
15.1.3 Definition of Termination Points (TP)
When ports are depicted on the user interface, the following abbreviations are used.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This section concerns the multiplex structure as well as on the information model of object-oriented
programming which was used when forming the user interface. As a rule, a Termination Point (TP) is the
starting and terminating point of a transmission segment. A distinction is made between the following types
of TPs:

CTP (Connection Termination Point)


The CTP represents the termination of a connection. The transmission signal is "terminated", i.e., the
received signal is monitored and the error signaling evaluated, while own-code signaling is inserted
in the transmitted signal.

TTP (Trail Termination Point)


The TTP represents the termination of a transmission segment. The signal is monitored and passed
on after modification in one form or another.

Both TP types exist on the SDH level and the PDH level.

CTPs on SDH level


On SDH level a distinction is made between the following CTPs:
AU4 (au4 Connection Termination Point)
The AU-4CTP represents both the creation and termination of an STM-1 connection. The High-order
Connection Supervision (HCS) function is included.
TU-x (Connection Termination Point), e.g. TU-12CTP, TU-2CTP, TU-3CTP
The TU-x CTP represents both the creation and termination of a VC-x connection. The Low-order
Connection Supervision (LCS) function is included.

CTPs on PDH level


On PDH level a distinction is made between the following CTPs:
E4 (Connection Termination Point)
The E4-CTP represents the non-intrusive monitoring of incoming 140 Mbit/s PPI

S4 (Connection Termination Point)


The S4-CTP represents the non-intrusive monitoring of outgoing 140 Mbit/s PPI

E32 (Connection Termination Point)


The E32-CTP represents represent the non-intrusive monitoring of incoming 45 Mbit/s PPI

S32 (Connection Termination Point)


The S32-CTP represents the non-intrusive monitoring of outgoing 45 Mbit/s PPI

E31 (Connection Termination Point)


The E31-CTP represents represent the non-intrusive monitoring of incoming 34 Mbit/s PPI

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

217/396

S31 (Connection Termination Point)


The S31-CTP represents the non-intrusive monitoring of outgoing 34 Mbit/s PPI

E1 (Connection Termination Point)


The E1-CTP represents the non-intrusive monitoring of outgoing 2 Mbit/s PPI. The Mon.
(monitoring) label indicates that is possible to enable the CRC4 control signal.

S1 (Connection Termination Point)


All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

The S1-CTP represents the non-intrusive monitoring of outgoing 2 Mbit/s PPI. The Mon.
(Monitoring) label indicates that is possible to enable the CRC4 control signal.

TTPs on SDH level


On SDH level a distinction is made between the following TTPs:
ES (Electrical Section TTP)
An ESTTP displays the physical characteristics of a port with electrical access (level and
code monitoring and conversion).
OS (Optical Section TTP)
An OSTTP displays the physical characteristics of a port with optical access (level and
code monitoring and conversion).
RST (Regenerator Section TTP)
An RSTTP displays the creation and/or termination of an RSOH (Regenerator Section
Overhead), i.e., rows 1 to 3 of the first 9xN columns of an STM-N frame.
MST (Multiplexer Section TTP)
An MSTTP displays the creation and/or termination of an MSOH (Multiplexer Section
Overhead), i.e., rows 5 to 9 of the first 9xN columns of an STM-N frame.
VC-4 (Trail Termination Point)
A VC-4 TTP represents both the creation and termination of a VC-4 path.

TTPs on PDH level


On PDH level a distinction is made between the following TTPs:
PPI (Trail Termination Point)
On the PDH side, an PPITTP corresponds to the ESTTP of the synchronous side.
Depending on the type, it can either display the characteristics of a 140 Mbit/s, a 45
Mbit/s, a 34 Mbit/s or a 2 Mbit/s port.
P (PPI Trail Termination Point)

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

218/396

On the PDH side, a pPITTP corresponds to the esTTP of the synchronous side.
Depending on the type, it can either display the characteristics of a 140 Mbit/s, a
45MBit/s, a 34 Mbit/s or a 2 Mbit/s port.

E4 (Trail Termination Point)


The E4-TTP represents the creation and/or termination of a 140 Mbit/s connection.
E3 (Trail Termination Point)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The E3-TTP represents the creation and/or termination of a 34 Mbit/s connection.


E2 (Trail Termination Point)
The E2-TTP represents the creation and/or termination of a 8 Mbit/s connection.
VC-4 (Trail Termination Point)
A VC-4 TTP represents both the creation and termination of a VC-4 path.
VC-3 (Trail Termination Point)
A VC-3 TTP represents both the creation and termination of a VC-3 path.
VC-12 (Trail Termination Point)
A VC-12 TTP represents both the creation and termination of a VC-12 path.

MSP definition

Transmit side, the MSNP (AU4-CTP) input enters two different MSNP/MSN (unprotected CTP) sources and
then the MSN-TTP working and protection sources (to insert the K1-K2 bytes) are sent to the own SPI
interfaces. Receive side; the working and protection MSN/MSNP outputs (AU4-CTP) enter in the switching
selector. The MSNP-TTP terminates the selected signal and checks the SSF and the MSP protocol failure.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

219/396

Figure 192.

ED

03

SDH Transport Level Diagram

SC.3: NE MANAGEMENT

3AL 98253 ADAA

220/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 193.

PDH Transport Level Diagram

15.1.4 Mapping Tables: TP Names


The TP names on the 1662SMC reflect the software model the user interface is based on. Therefore they
differ from the TP names given in the ITU-T recommendations. The following tables list the TP names
mapping conventions in the "Transmission" View.
Table 3. PDH TPs
ITU-T
PPITTP

TP names on 1662SMC
P

E4 CTP

eCTP

S4 CTP

p4

E31 CTP

eCTP

S31 CTP

p31

E32 CTP

eCTP

S32 CTP

p32

E1 CTP

eCTP

S1 CTP

p12Mon

E4 TTP

not supported
not supported

E3 TTP
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

221/396

ITU-T
E2 TTP

TP names on 1662SMC
not supported

VC-4 TTP

Vc4

VC-3 TTP

Vc3

VC-12 TTP

Vc12

ITU-T

TP names on 1662SMC

ESTTP

ElS

OSTTP

OpS

RSTTP

RST

MSTTP

MST

MSP

MSP

AU-4 CTP

Au4/Au4P

AU-4-4c CTP

Au4P-4c

VC-4 TTP

Vc4

TUG-3

Tug3

TUG-2

Tug2

TU-3 CTP

Tu3

TU-2 CTP

Tu2

TU-12 CTP

Tu12

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Table 4. SDH TPs

15.1.5 Cross-Connection Types


A cross-connection represents the logical connection between the input and output of the matrix, called the
matrix port.
The matrix only receives and transmits signals in GTI format. The Generic Transport Interface GTI, Alcatel's
standardized signal format for internal interfaces, is similar to the STM-1 format. The incoming signals are
mapped or converted to GTI format on the plesiochronous and synchronous I/O boards. This frame is based
on the STM-1 frame specified by ITU-T Recommendation G.707. It enables the transport of all signals in the
US hierarchy and ETSI hierarchy levels 1 to 4 (1.5 Mbit/s to 140 Mbit/s) mapped to Virtual Containers (VCs).
The VCs are sent from the I/O boards to both copies of the Matrix (A and B) via the GTI. The matrix performs
the cross-connection on the VC-4, VC-3, VC-2 or VC-12 level and transfers the VCs to the relevant I/O
boards via GTI. The configuration of both matrix copies is always identical. On the I/O boards, one GTI signal
is selected from Copy A or Copy B, based on quality.
The NE supports unidirectional, bidirectional and broadcast connections unprotected as well as protected.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

222/396

15.1.5.1 Unidirectional Connection


Information is transmitted exclusively from the input port to the output port (point-to-point); there is no routing
in reverse direction.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 194.

Unidirectional Connection

15.1.5.2 Bidirectional Connection


Information is transmitted between input port and output port in both directions (point-to-point).

Figure 195.

Bidirectional Connection

15.1.5.3 Broadcast Connection (Multi-leg / Multipoint)


In contrast to a cross-connection between just two points (point-to-point), one source and one sink, a
broadcast connection consist of one source and several sinks, different `legs' that share the same source TP.
In the example below, information is broadcast from one input to outputs A, B and C on three legs.

Figure 196.

Example of Broadcast Connection with Three Legs

A warning box indicates when the resources available for broadcast connections are exhausted.
N.B. Non-intrusive Monitoring
Adding a protection leg to a unidirectional cross-connection offers the ability to perform non-intrusive
monitoring on this cross-connection. No errors are introduced to the original cross-connection with applying
or removing the protection leg.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

223/396

15.1.6 Cross-Connection Protection


15.1.6.1 Protected Unidirectional Connection

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

A unidirectional connection is routed from Input A to the Output (primary route). In the case of a failure, the
system automatically switches to the protection path from protection Input B to the Output. This second
connection is permanently kept in hot standby operation.

Figure 197.

Bidirectional Connection - Input Protected

N.B. By means of this connection are created links with SNCP protection.
15.1.6.2 Protected Bidirectional Connection
A bidirectional connection is routed from Input A to the Output C (primary route). Input A (input protected)
can be protected:

Figure 198.

Bidirectional Connection - Input Protected

N.B. By means of this connection are created links with SNCP protection.
15.1.6.3 Protected Broadcast Connection
The protected broadcast is realized as a set of independent, protected, unidirectional connections using the
same pair of input termination points. Each protection can be forced, locked out or switched independently.
Therefore, if a failure occurs at a certain input, it is possible that only some of the protections of the protected
broadcast actually switch to the protection input.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

224/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 199.

Protected Broadcast

Figure up. Shows a broadcast connection from input A to outputs A, B and C. Leg 2 and 3 are protected via
input B, whereas leg 1 is not protected.
In current release only one out of N legs can be protected.
15.1.6.4 Drop and Continue Connection
A Drop and Continue connection is a composed by:

A unidirectional connection routed from Input A to the Output C and also to Input protecting B.

A unidirectional connection from Input protecting B to Output C.

A unidirectional connection from Output C to Input A.

Output C is protected; when receive from Input main the connection is defined normal,
when receive from Input Protecting main the connection is defined inverse.
All the connections are created in a single step of configuration.

Figure 200.

ED

03

Drop and Continue - Normal

SC.3: NE MANAGEMENT
3AL 98253 ADAA

225/396

15.2 Operative Sequence to execute Cross-Connections


This paragraph lists general procedure to realize cross-connection moving among the various menus.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Three main cases have been considered:

High order signal cross connection (AU4s between SDH ports);

High order concatenated signal cross connection (AU4xc between SDH ports)

Low order signal cross connection (TU12 cross connected with VC12; ports involved: SDH and
PDH )

4XANY TPs cross connection (ports involved: 4XANY and SDH)

ISA board TPs cross connection (ports involved:ISA, SDH or PDH)

Procedure for high order signal (AU4)

Select "Transmission" option from the "View" menu

Select "Transmission" " "Cross Connection" ""Cross Connection Management"

Click on "Create" in the Cross Connection Management windows; a new window called "Main Cross
Connection" is opened.
Select the correct value in the fields "Type" and "Protection"
Click on "Choose" relative to the "Input" field; a new window called "TP search" is opened.
On the "Equipment" field select the Board, in the "Termination Points" field select the AU4
Click on "OK"; the "TP search" window is closed.

In the "Main Cross Connection" window repeat the same on the "Output" field and on the "Prot.
Input" field for protected connections

Click on "OK" in the "Main Cross Connection" window to terminate the creation and subsequently
click on "Cancel" to go to the "Cross Connection Management" window.

Click on "Search" in the "Cross Connection Management" window to see the new cross-connection
created.

Procedure for AU4 concatenated (AU4c)


N.B. Before to create an AU4 concatenated cross-connection is necessary to define that the AU4s on a
STM-4 board are concatenated as explained.

Select "Transmission" option from the "Views" menu

Select "Transmission" " "Cross Connection" " "Cross Connection Management"

Click on "Create" in the Cross Connection Management window; a new window called "Main Cross
Connection" is opened.
Select the correct value in the fields "Type" and "Protection"

Click on "Choose" relative to the "Input" field; a new window called "TP search" is opened.
On the "Equipment" field select the Board, in the "Termination Points" field select the
concatenated AU4c (syntax example: r01sr1sl08/port#01-#01AU4P-4c)

ED

Click on "OK"; the "TP search" window is closed.

In the "Main Cross Connection" window repeat the same on the "Output" field and on the "Prot.
Input" field for protected connections

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

226/396

Click on "OK" in the "Main Cross Connection" window to terminate the creation and subsequently
click on "Cancel" to go to the "Cross Connection Management" window.

Click on "Search" in the "Cross Connection Management" window to see the new cross-connection
created.

Procedure low order signal (example TU12)

Select "Transmission" option from the "View" menu

Select "Transmission" ""Add TP"; a new window called "Tp search" is opened.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

On the "Equipment" field select the Board, In the "Termination Points" field select the AU4 and
click on "OK";
In the transmission window the AU4 block is displayed;

Select "Transmission" " "Terminate TP" ; a cross is displayed on the AU4 block

Click twice on the AU4 block and on the VC4 block that appears, then selecting the showed TUG3

Select "Transmission" " "Structure TPs" " then selecting the structure

N.B. The AU4 is then terminated on a VC4 of the matrix circuit of the COMPACT ADM unit.
The VC4 is automatically choose and indicated as "port # n", where "n" is the VC4 number.
This connection will appear on the Cross Connection Management view in a independent line.

If TU12 (example) are selected, in the transmission window clicking twice on the TUG3 and TUG2
blocks the TU12 are displayed

Select the TU12 to be used

Select "Transmission" " "Cross Connection" " "Cross Connection Management"; a new window
called "Cross Connection Management" is opened.

In the "Cross Connection Management" window click on "Create" button; a new window called "Main
Cross Connection" is opened.
Select the correct value in the fields "Type" and "Protection"

Click on "Choose" relative to the "Input" field; a new window called "TP search" is opened.
On the "Equipment" field select the Board, In the "Termination Points" field select the structured
TP (example: TU12 1.1.1)

Click on "OK"; the "TP search" window is closed.

Repeat the same on the "Output" field and on the "Prot. Input" field for protected connections

Click on "OK" in the "Main Cross Connection" window to terminate the creation and subsequently
click on "Cancel" to go to the "Cross Connection Management" window.

Click on "Search" in the "Cross Connection Management" window to see the new cross-connection
created.

Procedure 4XANY TPs cross connection


Note: before to create a cross connection the following step must be executed:

ED

configure the 4xANY board with the Equipment > Set menu

configure the 4xANY MODULES with the Equipment > Set menu and choose the traffic type that
must be supported by the module (e.g. FICON, FDDI etc.); after having selected the traffic type,
automatically a number of TPs (VC4) are generated for this port and can be viewed in the port view.
All the TPs must be used when the cross connection will be created.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

227/396

For details on 4xANY board refer to the Technical Handbook.


In the subrack view click twice on the 4xANY board; the board view will be opened .
Click twice on the module to be used; the daughter view will be opened.
Click twice on the daughter board icon; the port view will be opened with all the relevant TPs.
In the following will be explained how to connect one TpP of the 4XANY; repeat the same sequence for
all the TPs that has been generated when the traffic type has been defined.
Select the VC4 TP and then choose the Port >Cross Connection > Create Cross Connection

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

option of the menu bar; a new window called Main Cross Connection is opened.

Select the correct value in the fields Type and Protection

The Input field is automatically filled in

Click on Choose relevant to the Output field; a new window called Search for Cross Connection
Output is opened.

On the Equipment field select the Board to be used for the connection with the 4XANY board (for
example S4.1N), in the Termination Points field select the AU4

Click on OK; the Search for Cross Connection Output window is closed.
Click on OK in the Main Cross Connection window to terminate the creation.
repeat the same procedure for all the VC4 generated for the specific traffic type associated to the 4xANY
module.
To check the presence of the new crossconnection select the Port >Cross Connection > Cross
Connection Management option of the menu bar; a new window called Coss connection Management will
be opened

Click on the Search button; all the cross connected TP will be displayed in the Cross Connection
in list field.

Procedure ISA board TPs cross connection


Note: before to create a cross connection the following step must be executed:

configure the ISA board with the Equipment > Set menu

define the TP that must be created on the ISA board by selecting the Configuration > ISA Port
Configuration menu (refer to Chapter 20 for details)

The ISA board TP cross connection is similar to that described for the 4xANY board .

15.3 Cross-Connections management


A list of cross-connections can be displayed in the Cross-Connection Management dialog. The dialog can
be accessed via the Transmission or Port view or via Configuration menu.
Transmission view is presented with the View " Transmission pull down menu.
Port view is presented with the View " Equipment pull down menu, then clicking on the presented objects
with the sequence board>port.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

228/396

Figure 201.

ED

03

Cross connection management cascade menu

SC.3: NE MANAGEMENT

3AL 98253 ADAA

229/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Cross-Connection Management dialog is initially empty.


A list of cross-connections is displayed in the Cross-Connection Management dialog after selecting the
Search command.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

There are two possibilities of displaying a list of cross-connections:

Do not enter any search criteria and press the Search button to display a list of all existing crossconnections,

Enter Search Criteria (one or more) and then press the Search button to display a selection of
cross-connections. Set Ignore for attributes not to be used as filtering criteria.

Use button Cancel Search to cancel an active search request or close the dialog.
15.3.1 Search Criteria

Name (not supported.)


Number of the cross-connection (automatically assigned)

ACD (not supported.)


Enter the Access Control Domain of the relevant cross-connections: E= connection made with
1353SH, M= connection made with 1354RM, empty= connection made with CT.
This filter option can only be used, if at least one ACD is defined on the NE and one or more crossconnections are assigned to this ACD(s).

Type
Select the connection type:

Unidirectional

Bidirectional

Multipoint

Drop Continue

Protection
Select protection functionality:

Protected

Not protected

TP Class
Select one of the TP types involved in the requested cross-connection.

State
Select the connection state:

Activated

Deactivated (not operative in current release, the connection state is always Activated)

Prot. State
Select the protection state:

ED

Forced to Input

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

230/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Forced to Protecting

Manual Switch to Input

Manual Switch to Protecting

Auto. Switch to Input

Auto. Switch to Protecting

Lockout

Normal I

Normal P

TP ID Prefix
Enter the TP type and physical location of the port, or only the physical location at least down to
board level, according to the following format:

R<rack#>s<subr.#>b<board#>/port#<port#>-TP.
The # within brackets identifies a number.

Figure 202.

ED

03

Cross-Connection Management Dialog (Initial State)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

231/396

15.3.2 Cross-Connection List


After a successful search, a read only list of cross-connections matching the search criteria appears. The
number of matching cross-connections is displayed in the upper left corner of the list. The list contains
information concerning the following parameters for each cross-connection:

Prot. State
Detailed switching information in the format:
<Protection state> <traffic Ind> (<location>: <signal state>-<switch status>,
[<Location>: <signal state>-<switch status>])

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

<Protection state>
Normal, Auto, Lockout, Forced or Manual.

<Traffic ind>
Indicates the location of current traffic:
P (Protecting input) or I (Input).

<Location>
Indicates the location of the error signal:
P (Protecting input) or I (Input)

<Signal state>
Indicates the signal state: SD (Signal Degrade) or SF (Signal Failure)

<Switch status>
Status of the switch:
C (completed) or p (pending)
Example:
Auto I (P: SD-c)
There has been an Automatic switch from the protecting input to the Input where the traffic is
currently located. The reason for the automatic switch was Signal Degrade in the Protecting input.
The switch was completed.

State
Connection state indicating whether cross-connection is A (activated) or D (deactivated)

Dir.
Direction-related connection type:
uni (directional), bi(directional) or mp (multipoint), DC_N (Drop & Continue Normal) or DC_I (Drop &
Continue Inverse)

Input
Signal source; contains the TP type and physical location of the port according to the format
<Rack#>-<subr. #>-<Board#>-<port#>, <port#>#TP
The # within brackets identifies a number.

ED

Protecting Input

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

232/396

Protecting source (for protected cross-connections only); contains the TP type and physical location
of the port according to the format
r<rack#>s<subr.#>b<board#>/port#<port#>-TP.
The # within brackets identifies a number.

Output
Signal
destination
for point-to-point cross-connections, the TP ID of the destination is specified according to the format

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

r<rack#>s<subr.#>b<board#>/port#<port#>-TP ; for multi-leg cross-connections, the string "multiple


Legs" appears instead.
At the bottom of the dialog is a range of buttons to start actions on the listed cross-connections. Before
starting any action apart from creation or printing, mark at least one cross-connection.
To mark several cross-connections (multi-select) that are listed in succession, select the first crossconnection of a block with a mouse click and the last one with a mouse click while pressing the <Shift> key.
Or, mark a number of individual cross-connections by clicking the mouse button while pressing the <Control>
key.
Deselect cross-connections by clicking on the respective row while simultaneously pressing the <Control>
key. To deselect a number of cross-connections at a time, press the <Shift> key and hold it down while
moving the mouse pointer to the last entry.
All actions that may affect traffic must be confirmed. A confirmation dialog pops up in this case and the user
has to confirm the requested action.

Figure 203.

ED

03

Cross-Connection Management Dialog (After Search)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

233/396

15.3.3 Actions available


The following actions are available:

Create a cross-connection.
The Main Cross-Connection dialog is opened.

Modify a Cross-Connection.
Available if just one cross-connection is selected from the list. The Main Cross-Connection dialog
is opened.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Activate a Cross-Connection.
Available if at least one cross-connection is selected from the list. Not operative.

Deactivate a Cross-Connection.
Available if at least one cross-connection is selected from the list. Not operative.

Delete a Cross-Connection.
Available if at least one cross-connection is selected from the list.

Split a Cross-Connection.
Available if at least one bidirectional cross connection is selected from the list.

Join Cross-Connections.
Available if two cross connections are selected. Not operative.

Protection Switching.
Available if exactly one protected cross-connection is selected from the list. The Protection Actions
dialog is opened.

Print.
Prints the filtered list of cross-connections.

The dialog has to be closed explicitly.

15.4 Create/Modify Cross-Connections


Creation and modification of cross-connections are performed in the Main Cross-Connection dialog. The
dialog can be accessed via the Transmission or Port view as for the following menus example or by using
the Create or Modify buttons in the Cross-Connection Management dialog.
The dialog box of Figure below is presented ( Main Cross Connection view).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

234/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 204.

Create Cross-Connections

To prevent operation faults, the system is designed according to the following guidelines:

ED

All operations that may affect traffic must be confirmed. The subsystem provides a confirmation
dialog box before the operation can be executed.

If the window displays an existing cross-connection, the OK button is insensitive when this crossconnection is assigned to NML or it is not assigned to the user profile.

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

235/396

If the window is used to create a new cross-connection, the system verifies that the relevant TPs can
be used (not assigned to NML and assigned to the user profile) after the OK button is pressed. If a
specified TP is not permitted, the corresponding message box appears.

15.4.1 Cross-Connection Parameters


The "Main Cross Connection" permits to create the cross connections.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

A cross-connection is defined through a set of parameters, which depend on the connection and protection
type. Only those parameters, which are permitted within the current context, can be accessed. All others are
disabled (faded gray).
To create a cross-connection, one or more of those parameters must be defined according to the crossconnection type. Table 1. Gives an overview about the optional and mandatory input parameters for the
various cross-connection types. Activate the relevant entry boxes first of all by clicking on them with the
mouse.
Configurable Parameters

Type
Select the connection type:

Unidirectional

Bidirectional

Drop Continue

D&C Topology
Select the direction for Drop Continue:

Normal

Inverse

Protection
Define protection state:

Protected

Not Protected

Prot. Criteria (only available for protected connections)


Clicking on the Prot. Criteria button, for the Protection Criteria dialog is opened, where the user can
display and configure the SNCP Type Protection. No protection criteria for automatic protection
switching can be configured.
The following SNCP Type is available:

ED

SNCP-I (Inherently monitored Sub-Network Connection Protection)

SNCP-N (Non-intrusively monitored Sub-Network Connection Protection)

SNCP-S (Sub-layer Sub-Network Connection Protection) (Not operative in current release)

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

236/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 205.

Protection Criteria

Revertive (available only for protected connections)


Select whether protection is to be revertive or not.
In Revertive mode, a protected service is switched back to its initial, protected element when the
fault has been eliminated.
When Revertive mode is active, the Wait To Restore protection period prevents several protection
switches being initiated as a result of an intermittent failure. The protected element must be errorfree during this defined period of time before a protected service is switched back to it.
The Wait To Restore time period is fixed to 5 minutes.
In Non-revertive mode, switchover to the protecting element is maintained even after the fault has
been eliminated.

HOT (available only for protected connections) Not operative in current release
To enter the Hold Off Time expressed in msec. HOT is the time between declaration of Signal
Degrade or Signal Fail, and the initialization of the protection switching algorithm.

Input
To enter the input TP, click the relevant Choose button and select the TP in the TP Search dialog.
Otherwise, select the input field and enter the name of the TP directly.

Prot. Input
To enter the protecting TP, click the relevant Choose button and select the TP in the TP Search
dialog. Otherwise, select the input field and enter the name of the TP directly.

Output
It is possible to enter one or more output TPs.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

237/396

To enter one output TP, click the relevant Choose button and select the TP in the TP Search dialog.
Otherwise, select the input field and enter the name of the TP directly.
To enter more than one output TP and create a broadcast connection, proceed as described
previously and press button Add afterwards. The previously chosen TP is then moved to the list box
located below. Click the Choose button and select the next TP in the TP Search dialog. Otherwise,
select the input field and enter the name of the TP directly. Repeat this procedure for each destination
TP. A list of all the selected output TPs is displayed in the list box located below it.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To delete a leg from the list, select the TP in the list box and click on the Delete Leg button.
N.B.
Non-intrusive
Monitoring
Adding a protection leg to a unidirectional cross-connection offers the ability to perform non-intrusive
monitoring on this cross-connection. No errors are introduced to the original cross-connection with
applying or removing the protection leg.
Table 5. Optional and Mandatory Configurable Parameters for Cross-Connection Creation
Input Parameters

Unidirectional/Bidirectional Cross
Connection
Not Protected

Type

Protected

Broadcast Cross Connection


Not Protected

Unidirectional/Bidirectional

D&C Topology

Protected

Unidirectional

Normal/inverse

Protection

Not Protected

Protected

Not Protected

Protected

Protection

SNCP-1

SNCP-1

Criteria

SNCP-N

HOT
operative)

(NOT

SNCP-N

Protected

Revertive

One TP

One TP

One TP

One TP

One TP

One TP

One TP

One TP

One or more TPs

One or more TPs

Input
Protecting Input
Output
_ not available
x configuration optional

Non-configurable Parameters

CC Topology
The topology of the cross-connection is indicated via two icons. The left-hand icon displays the
current topology and the right one displays a view of the topology following confirmation of the
current modifications.
In addition, the color of an icon indicates the connection state of the cross-connection:
Green -> active
Brown -> inactive
The icon is set according to the entries made in Type and Protection:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

238/396

TPs not cross connected

Unidirectional, not protected

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Bidirectional, not protected

Unidirectional, protected

Bidirectional, protected

Broadcast, not protected

Broadcast with one protected leg

Drop & Continue normal

Drop & Continue inverse

Loopback connection: unidirectional, same input and output TP


Figure 206.

Cross-Connection Icons

Example:

Figure 207.

ED

03

Creation of a Unidirectional, Non-Protected Cross-Connection

SC.3: NE MANAGEMENT
3AL 98253 ADAA

239/396

-- Input TTI
The received Trail Trace Identifier of the far end signal is displayed. Not operative in the current Release.
-- Output TTI
The Trail Trace Identifier of the transmitted (near end) signal is displayed. Not operative in the current
Release.
15.4.2 Create a Cross-Connection

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This chapter lists the steps the user has to take to create a cross-connection using The "Main Cross
Connection"
For a detailed description of the single parameters.
For information on cross-connection types.
N.B. After creation of a cross-connection, the cross-connection list in the Cross Connection Management
dialog is not automatically updated. Use button Search in this dialog to update the list.
Create a Point-to-Point Cross-Connection (unit- or bidirectional)
1) Select the cross-connection type.
2) Select the protection state.
3) Select or type in the input TP.
To enter the TP, click the Choose button and select the TP in the Search for Cross Connection
Input dialog, or select the input field and enter the name of the TP directly.
The Search for Cross Connection Input dialog offers the possibility to list TPs according to different filter
criteria. E.g. to obtain a list of all not connected AU-4 TPs of a rack, first select the rack in the left list box,
then select the filter criteria Connection State "not connected" and Class "AU-4" and click on button Search.
The matching TPs are listed in the right list box. Select the input TPs in the list and confirm with Ok.
For a more detailed description on the Search for Cross Connection.
4) Select or type in the output TP as described in Step 3).
The following steps only apply to protected cross-connections:
5) Select or type in the protection TP as described in Step 3).
6) Configure the Revertive mode
7) Configure the Protection Criteria (Prot.Criteria)
8) The Hot (Hold Off Time) is not operative in current release
Press the button Ok to confirm the creation.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

240/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 208.

Create a Bidirectional Protected Cross-Connection

Create a Broadcast Connection


1) Select the cross-connection type "unidirectional"
2) Select the protection state.
3) Select or type in the input TP.
To enter the TP, click the Choose button and select the TP in the Search for Cross Connection Input dialog
or select the input field and enter the name of the TP directly.
This dialog offers the possibility to list TPs according to different filter criteria. E.g. to obtain a list of all TU12
TPs of a board, first select the board in the left list box, then select the filter criteria Connection State "Ignore"

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

241/396

and Class "TU12" and click on button Search TPs. The matching TPs are listed in the right list box. Select
the input TPs in the list and confirm with Ok.
For a more detailed description on the Search for Cross Connection.
4) Select or type in the output TPs as described in Step 3 )
Press the button Add Leg in the Main Cross Connection dialog and all output TPs are displayed in
the list box under the output field.
To delete a leg from the list, select the TP in the list box and click on the Delete Leg button.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following steps only apply to protected broadcast connections:


5) Select or type in the protection input TP. Note that each single protected leg of the broadcast has to be
assigned to the same protecting input.
Proceed as described in Step 3 ). Afterwards, select the protected output TP in the output list box and
click button Protect Leg. The leg is then marked as "protected" in the list box. Repeat this procedure
for each protected output TP (only one protected leg is supported in current release).
To unprotect a leg from the list, select the protected TP in the list box and click on the Unprotect Leg
button.
6) Configure the criteria for automatic protection switching.
7) Configure the Protection Criteria (Prot.Criteria)
8) The HOT (Hold Off Time) is not operative in current release
Press the button OK to confirm creation.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

242/396

Figure 209.

ED

03
Search for Cross-Connection Output

SC.3: NE MANAGEMENT

3AL 98253 ADAA

243/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 210.

ED

03
Create an Unprotected Broadcast Cross-Connection

SC.3: NE MANAGEMENT

3AL 98253 ADAA

244/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 211.

Create a Protected Broadcast Cross-Connection

15.4.3 Modify a Cross-Connection


When modifying a cross-connection, note that some of the transformations involved may affect traffic
(because the system may have to destroy and re-create the cross-connection to perform the necessary
transformation). As mentioned at the beginning of this chapter, the user is required to confirm operations
affecting traffic, i.e. a confirmation window warns the user.
Within the Main Cross Connection dialog, modification of a cross-connection is restricted to the protection
state and the parameters required by the protection. Refer to Table 2. For an overview of the accessible
parameter when the protection state has been changed from "not protected" to "protected" and vice versa.
For a description of the parameters, please refer to the previous Para. 1.1.1 on page 2.
To modify a cross connection selects one from the connection list and then click on the Modify button.
N.B. After modification of a cross-connection, the cross-connection list in the Cross Connection
Management dialog is not automatically updated. Use button Search in this dialog to update the list.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

245/396

Table 6. Modifiable Parameters


Input Parameters

Modification
Not Protected to Protected

Protected to not Protected

Normal/inverse

Normal/inverse

Protected

Not Protected

Protection Criteria

HOT (NOT operative)

Unprotected

Protected

Revertive

Input

Protecting Input

Output

Type
D&C Topology

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Protection

_ Not available
X configuration optional
The following few facts should be taken into consideration when modifying connections.
Unprotect a protected cross-connection:
When a protected cross-connection is being unprotected (protection changed to "not protected"), the
dialog displays the additional option button Unprotected.
It offers the choice of whether to keep the protected input TP (Input) or the protecting input TP (Prot.
Input) as the only signal source of the new unprotected cross-connection. Ensure that the active TP is
selected (i.e. check the protection state in the Cross-Connection Management dialog).
An example is in the following Figure.
In addition, a question box appears, asking the user to confirm the unprotect action.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

246/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 212.

Unprotect a Unidirectional Cross-Connection

Protect an unprotected cross-connection:


When an unprotected cross-connection is being protected, the Prot. Input button is available to
select the protection input connection to insert.
An example is in the following Figure.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

247/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 213.

Protect one Leg of a Broadcast Connection

15.5 Activate/Deactivate/Delete Cross-Connections


15.5.1 Activate a Cross-Connection
Not supported in current release.
The Cross Connection Management dialog provides the possibility of displaying a selection of existing
cross-connections. The connection state (Act = A or D) is indicated in this connection list.
To activate a cross-connection, select one from the connection list (see) and then click on the Activate
button to initiate the process. A confirmation box appears in which to confirm the state change request. The
connection in the list is automatically updated to indicate the new connection state (Act = A).
If the set of cross-connections selected from the list includes both activated and deactivated crossconnections, clicking the Activate button only initiates actions on the deactivated cross-connections, which
were selected.
15.5.2 Deactivate a Cross-Connection
Not supported in current release.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

248/396

After creation, a cross-connection is automatically in an active state. To deactivate a cross-connection, select


one from the connection list and then click on the Deactivate button to initiate the process. A confirmation
box appears in which to confirm the state change request. The connection in the list is automatically updated
to indicate the new connection state (Act = D).
If the set of cross-connections selected from the list includes both activated and deactivated crossconnections, clicking the Deactivate button only initiates actions on the activated cross-connections, which
were selected.
15.5.3 Delete a Cross-Connection

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Only deactivated cross-connections should be deleted. However, deletion of active cross-connections is


possible.
NOTE: the Delete crossconnection action is not possible in the case that is still existing any
operation/connection/termination on the underlying supported signals, such as:

Performance Monitoring on lower or higher TPs

POM / HPOM operations

Lower order Connections

Higher order Connections

Lower/Higher order Path Terminations

Loopbacks

LAN/LAPD (and any comm/routing channel)

Auxiliary channels

Thus the deletion of every active operation/connection/termination is necessary, in the same order as above
listed, before the deletion of a crossconnection.
To delete a cross-connection, select the corresponding connection from the list and click on the Delete
button. To prevent operation errors, the user must confirm the deletion request.
The deleted cross-connection automatically disappears from the connection list when the operation is
successful.

15.6 Split and Join Cross-Connections


Not supported in current release.
15.6.1 Split a Cross-Connection
Precondition
Only bidirectional cross-connections can be split.
Split
Select one or more bidirectional cross connections from the list in the Cross Connection Management
dialog and press Split. The cross-connections are split without further confirmation from the user.
The original cross connection(s) disappear from the list in the Cross Connection Management dialog after
a successful action. The user has to press Search to see the new cross connections.
Depending on the protection state of the original cross-connection, the split action has the following effect:
a) Unprotected Cross-Connection
An unprotected bidirectional cross-connection is split into two unidirectional cross-connections with
the input TP in one of them being the output in the other and vice versa (see Figure below.).
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

249/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The new cross connection has the same name and activation status as the old bidirectional one.

Figure 214.

Split/Join Unprotected Bidirectional Cross-Connection

b) Protected Cross-Connection
Splitting a protected connection results in one protected unidirectional cross-connection and one
broadcast with two legs. The input of the original cross-connection is one of the legs in the broadcast.
The other leg in the broadcast is the protecting input. The input of the broadcast is the output of the
original protected cross-connection.

Figure 215.

ED

03

Split/Join to Protected Bidirectional Cross-Connection

SC.3: NE MANAGEMENT
3AL 98253 ADAA

250/396

15.6.2 Join Two Cross-Connections


Precondition
Two cross-connections can be joined if they match the following characteristics:

The connections are either

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1) Both unprotected, unidirectional and the input is the output of the other one, or
2) One of them is protected and unidirectional, and the other one a broadcast with two legs.
Restriction: the input of the broadcast connection has to be the output of the protected connection
and the legs of the broadcast match the input and the protection input of the unidirectional
connection, also refer to Chapter Split a Cross-Connection, effect b).

Both cross-connections have the same connection state (activated or deactivated).

Both cross-connections have the operational state "enabled", i.e. they are listed in black color in the
Cross Connection Management dialog.

Join
Select exactly two cross connections in the Cross Connection Management dialog and press the Join
button. The cross-connections are joined without further confirmation from the user.
The original cross connection(s) disappear from the list in the Cross Connection Management dialog after a
successful action. Press Search to see the new cross-connections in the list.
The result is either a bidirectional or a protected bidirectional cross-connection.
If the original cross-connections have different names, the new name is a concatenation of the names of
both of them.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

251/396

15.7 Protection Switching


The Protection Actions dialog is displayed after clicking on the Protection button in the Cross Connection
Management dialog.
Users can only switch protection on cross-connections belonging to them and not assigned to the NML. A
second condition is that protection is enabled for the cross-connection concerned (protection parameter is
set to "protected").

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The three protection actions Force, Lock Out and Manual Switch belong to different levels, whereby Lock
has the highest priority and Manual Switch the lowest.
Note that a protection state can only be changed within the same or from a higher priority level, e.g. Force
To Protecting can be reverted with Release but not with Manual Switch To Input.

Figure 216.

Protection Actions Dialog

The dialog window enables the user to perform protection- related operations on protected crossconnections. These are:

Force to Input (not operative in current release)


The cross-connection is switched to the protected input regardless of signal quality. Automatic
protection is disabled.

Force to Protecting (Input)


The cross-connection is switched to the protecting input regardless of signal quality. Automatic
protection is disabled.

Release Force
Forced switching is disabled and automatic protection switching re-enabled.

Manual Switch to Input (not operative in current release)


The user can switch over to the protected input manually. Switching over is not executed if the signal
quality on the protected path is worse than on the protecting path.

Manual Switch to Protecting Input (not operative in current release)


The user can switch over to the protecting input manually. Switching over is not executed if the
signal quality on the protecting path is worse than on the protected path.

ED

Release Manual Switch (not operative in current release)


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

252/396

A manual switch is disabled and automatic protection switching re-enabled.

Lock Out to Invoke


The connection path is locked for protection switching, i.e. neither forced nor manual switching can
be performed.

Release Lock
The protection lock is disabled.

N.B. All the operations listed are context-dependent and are enabled or disabled ("grey") accordingly.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

After completion of protection switching, the list entry in the Cross Connection Management dialog is
updated automatically.
After clicking on an action button and completing the action initiated, the dialog disappears automatically.

15.8 Print
This option is used to print the currently filtered cross-connection list and the related filter settings on the
default printer or to a file in postscript or ASCII format.

Figure 217.

Select Printer

N.B. If no printer is installed, there is no error message displayed to indicate this.

Figure 218.

ED

03

Select Output Format

SC.3: NE MANAGEMENT
3AL 98253 ADAA

253/396

15.9 Show Cross-Connected TPs

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

An overview of signal flow can be requested by means of a user action. The user can select a TP and initiate
the action Show Cross Connected TPs from the Transmission view.

Figure 219.

Show Cross Connected TPs view

The result is that all other TPs connected to the currently selected TP are displayed. A line indicates the
connection.
This functionality should only be applied selectively (either for a single TP or selected group of TPs).
Expanding and hiding TPs that are associated with the currently selected TP (e.g. show all TPs that are
above the TU12CTP) enables all the related TPs to be added to the view so that the complete signal flow
can be illustrated.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

254/396

Figure 220.

ED

03
Show Cross Connected VC4 of an AU4

SC.3: NE MANAGEMENT

3AL 98253 ADAA

255/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

16 OVERHEAD MANEGEMENT
16.1 Introduction
The purpose of this set of dialogs is to handle the operations on the Overhead (OH) bytes of the NE.
The possible operations are:

Overhead cross-connection

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- Cross-connection between 2 or more OH bytes


- Termination of an OH byte onto an auxiliary port or vocal channel
- Total Pass-through of the MSOH bytes for some cards
- Definition of the Phone Parameters
There is a TP associated to every OH byte and to every auxiliary port, so TP could be used instead of OH
bytes or auxiliary port, depending on the context.

16.2 OH Connection overview


Here are described the possible OH connections

OH Cross-connection

The operator has to be able to cross-connect 2 or more OH bytes on 2 different boards.


The possible cross-connection types are:

Unprotected bidirectional point to point

The steps an operator has to do in order to perform the cross-connection are the following:

Create the OH TPs involved in the operation

Create the OH cross-connection:


- Select type of cross-connection
- Select the input OH TP involved in the operation
- Select the output OH TP involved in the operation

After having deleted an OH cross-connection, the involved TPs have to be deleted.

OH Termination

The operator has to be able to terminate one OH byte onto an auxiliary port or vocal channel.
The steps an operator has to do in order to perform the OH bytes termination are the following:

Create the OH TP involved in the operation

Create the OH byte termination:


- Select the created OH TP
- Select the auxiliary port/vocal channel TP involved in the operation

After having deleted an OH byte termination, the involved TP have to be deleted.

ED

Total MSOH Pass-through

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

256/396

For STM ports it make sense to allow the operator to perform a total pass-through of the MSOH bytes. A
total msoh pass-through connection (connection between msPassThroughCTP points) is set-up only if no
single msoh pass-through connection are set and if no single msoh cross-connection are set. If a total msoh
pass-through connection is set, a single msoh pass-through connection or a single msoh cross-connection
cannot be set.
The steps an operator has to do in order to perform the total MSOH pass-through are the following:

Create the msPassThroughCTP points involved in the operation

Create the total MSOH pass-through:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- Select the input msPassThroughCTP point involved in the operation


- Select the output msPassThroughCTP point involved in the operation
After having deleted a total MSOH pass-through, the involved msPassThroughCTP points have to be
deleted.

16.3 Overhead views


The Overhead Views allows performing the previously presented operations.
To access select Overhead option from the Configuration pull down menu; the following options are
presented in the cascading menu.

OH Cross Connection.

OH Phone Parameters.

OH TP creation.

OH TP deleting.

Figure 221.

Overhead options

The options are described in next paragraphs.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

257/396

16.4 OH Cross Connection


Select the Configuration pull down menu. Select the Overhead option and then from the cascading menu
the OH Cross Connection option.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Cross-Connection Management for Overhead dialog opens and allows to start the configuration.

Figure 222.

Cross Connection Management for Overhead dialog

It is similar to the dialog used for the cross-connection of the TP for paths, then the same description
and functions are valid.
Next configuration steps use the Main Cross-Connection for Overhead dialog and the TP Search dialog,
also in this case already described for path management.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

258/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 223.

Main Cross-Connection for Overhead dialog

There is one big difference between the OH TPs and the other kinds of TPs: the OH TPs have to be:

Created ONLY BEFORE a cross-connection/termination operation involving them has been


performed.

Deleted AFTER a cross-connection/termination deleting involving them has been confirmed.

The current implementation of the TP Search Dialog (TPSD) works only with created TPs.
In the following a description of the main functions and commands is given, also to list the Supported and
Not Supported operation.
Cross-Connection Management for Overhead dialog

Supported operations
Search cross connections/terminations according to one or more of the following filtering
attributes: type, TPs . The operator can set the filtering criteria, can start the search and select
one or more cross connections/terminations among those presented in a read-only list as a
result of the search operation. For each cross connection/termination matching the filtering
criteria, the following information is shown: direction (bidirectional) and the input, output TPs
involved ;
After choosing one or more cross connections/terminations, this dialog allows to:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

259/396

Delete the selected xconnection/termination

Go to the "Main Cross Connection for Overhead" dialog and modify the existing cross
connection/termination

Note: this dialog disappears only when the user explicitly clicks on the close button.
Delete operations can be performed on several cross connections/termination at the same time.
Modify operations can be performed only on single cross connections/terminations.
The OH xconnections are automatically active at the moment of their creation.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The operation buttons availability follows some rules:

The Delete and Print buttons are enabled only if at least one item is selected from the list.
A special dialog will ask the user for a confirmation.

The modify button is enabled if one (and only one) item is selected. It brings up the Main cross
connection dialog.

The create button is always enabled. It brings up the Main cross connection Dialog.

When some operation may affect the existing traffic, the operator is warned about that, and a confirmation
dialog must be answered to carry on/cancel the operation. The choices for this dialog are: yes/no for single
items, yes to all/cancel for multiple items

Not Supported operation

When used for OH purposes, the Cross-Connection Management dialog doesn't support the following
functionalities:

Protect cross connections/terminations: all the OH cross connections/terminations are unprotected

Activate/Deactivate cross connections/terminations: all the OH cross connections/terminations are


automatically active since their creation

Split cross connection/termination

Modify Cross Connection Termination

16.4.1.1 Main Cross-Connection for Overhead dialog


See Figure up.
According to the philosophy of offering only meaningful operations to the user, and being the OH cross
connection operations a subset of those applying to the general cross connections (e.g: protections are not
allowed), some fields of this dialog are disabled.
By clicking on the proper portions of the dialog and on the proper buttons, the operator can perform the
operations hereafter listed:

Selection of the cross-connection type

Selection of the input TP involved in the cross-connection

Selection of the output TP involved in the cross-connection

In order to do that the operator can either type in the involved TPs ID or use the TP Search dialog.

Supported operations
When creating a new cross connection, some or all of the following operations are available,
depending on the NE type characteristics:
Choose one input TP

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

260/396

Choose one output TP


It is possible to directly type in the TP name or to click on the Choose button to select a TP from
the TP Search dialog box
16.4.1.2 TP Search dialog
The TP Search dialog currently offers:

Navigation rack/subrack/board/port

A list of TPs to choose from

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

When used in the OH domain, this dialog is a subcase of the most generic TP Search.
The operator can choose among a list of:

All the possible OH TPs belonging to a specified class: no board selected and MS, RS or VC class
selected

All the possible OH TPs belonging to a specified board/port: board/port selected and no TP class
selected

All the possible OH TPs belonging to a specified board/port and class: board/port selected and MS,
RS or VC class selected

All the OH TPs already connected (also accordingly to the connection type)

All the OH TPs not yet connected

A combination of the above options

In this Network Element to connect the auxiliary / vocal channels and the Overhead bytes the following
operative indication must be observed:
-

The auxiliary and vocal channels TPs are in the SERVICE board of slot 20
The auxiliary channels are:

1 x G.703 2Mbit/s (not operative in current release); in the screen are indicated as:
- R01sr1sl20/port#03--#01-eOCTP
Expanding this TP, 31 referred TPs are presented

2 x G.703 64Kbit/s; in the screen are indicated as:


- R01sr1sl20/port#04-#01-aux
- R01sr1sl20/port#05-#01-aux

2 x V11; in the screen are indicated as:


- R01sr1sl20/port#01-#01-v11CTP
- R01sr1sl20/port#02-#01-v11CTP

2 x V24; in the screen are indicated as:


- R01sr1sl20/port#01-#01-v24CTP
- R01sr1sl20/port#02-#01-v24CTP

1 x phonic interface (voice channel); in the screen are indicated as:


- R01sr1sl20/port#01-#01-q23TTP

Expanding this TP, four referred TPs are presented


- R01sr1sl20/port#01-#01-q23TTP
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

261/396

- R01sr1sl20/port#01-#02-q23TTP
- R01sr1sl20/port#01-#03-q23TTP
- R01sr1sl20/port#01-#04-q23TTP
-

The other boards used to terminate or cross-connect the OH bytes are the STM-n boards.
The OH TP is present in MS, RS and VC4 TP Class.

In these TPs the indication "...#0011 to 0099 (MS or RS) are referred to the coordinates of the Section
Overhead bytes on the SDH frame (1,1 to 9,9)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The voice channel are identified by the "ow" indication, the "FU" is for Future Use, the "NU" is for National
Use, "UC" is for User Channel and "Pass" is for Pass through channel.
The examples of the figure in this OH connection chapter can be helpful to the operator

16.5 OH TP creation
Select the Configuration pull down menu. Select the Overhead option and then from the cascading menu
the OH TP creation option.
The OH TP creation dialog opens and allows to create the OH TP to cross connect.
In detail, the dialog-box contains the following graphical object:
- a Choose button is used to display a list of OH Tps to be created. The Choose button starts the
TP Search with predefined filtering; the TP Search dialog allows the operator to visualize only not
created OH Tps.
To visualize the OH TP in the TP Search view double clicks on the MS, RS or VC4 Tp.
- OH TP field displays the label of the selected OH Tp to be created.
Apply button is used to perform a create request of the TP displayed in the OH TP field. After having
performed the create request, the OH TP field is set to empty.
Close button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

Figure 224.

ED

03

OH TP creation

SC.3: NE MANAGEMENT
3AL 98253 ADAA

262/396

Figure 225.

ED

03
OH Search TP for creation

SC.3: NE MANAGEMENT

3AL 98253 ADAA

263/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

16.6 OH TP deleting
Select the Configuration pull down menu. Select the Overhead option and then from the cascading menu
the OH TP deleting option.
The OH TP deleting dialog opens and allows deleting the OH TP no more involved in an OH crossconnection.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In detail, the dialog-box contains the following graphical object:


- a Choose button is used to display a list of OH Tps to be deleted. The Choose button starts the
TP Search with predefined filtering; the TP Search dialog allows the operator to visualize only
created and not cross-connected OH Tps.
- OH Tp field displays the label of the selected OH Tp to be deleted.
Apply button is used to perform a delete request of the TP displayed in the OH Tp field. After having
performed the delete request, the OH Tp field is set to empty.
Close button close the dialog without changes of the data.
Help button provides some useful information about the dialog.

Figure 226.

ED

03

OH TP deleting

SC.3: NE MANAGEMENT
3AL 98253 ADAA

264/396

16.7 OH Phone Parameters


The OH phone parameters option permits to configure the telephone number and to manage the parameter
"phonic extension".

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the Configuration pull down menu. Select the Overhead option and then from the cascading menu
the OH Phone Parameters option. Figure below. Opens.

Figure 227.

Phone Parameters dialog window

In the window are presented:

The interface field (at the top) where can be selected the phonic interfaces to be configured.

The phone number field, to set the telephone number for operator calls on the phonic interface.

The phonic extension field, where enable or disable the extension of the selected phonic interface.
If enabled the phonic signal is extended towards the external on the access panel of the NE.
Not operative in current release

Apply button performs the configuration change of the modified phone parameters of the selected phonic
interface without close the dialog
Close button close the dialog without changes of the data.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

265/396

17 Performance Monitoring
17.1 Introduction
The Performance Monitoring domain on the NE covers the monitoring of counter values for trail termination
points and connection termination points.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Examples of these counters are Error Seconds (ES) and Severely Error Seconds (SES).
The Performance Monitoring domain counts these errors during specified granularity periods (15 min, 24h)
and stores the values in history data logs.
For the purpose of quality supervision, the values of the error counters can be compared to user-defined
threshold levels. If a counter value has crossed a threshold level, a notification (threshold crossing alarm) is
issued.
The principle performance management functions are:

Configuration of the counting interval for each performance measurement point.

Collection of the performance data.

Configuration of the quality thresholds that generate alarms and log records when predefined values
are exceeded.

On the ETHERNET boards a set of performance counters are foreseen, for future releases ,for QoS and
maintenance purpose. By selecting the GMAU TP and subsequently the Transmission >Performance menu,
the following options are available:
Configure Performance Monitoring. Not operative in current release.
Display Current Data. Not operative in current release.
Display Maintenance Counter. Not operative in current release.
17.1.1 Overview
These functionalities are described in the following chapters in addition to general information concerning
performance monitoring on the NE.

Chapter Configuration deals with the configuration of performance monitoring

Chapter Display Current Data deals with displaying current performance data

Chapter Display History Data deals with displaying history performance data

Chapter PM Threshold Table Selection deals with the selection of threshold tables

Chapter PM Threshold Table Modification/Display deals with the modification of threshold tables
and permits or display the same

17.1.2 Supported Performance Counters


The NE uses performance counters to count transmission errors.
A set of performance counters is provided according to the Termination Point (TP), where performance
measurement occurs.
The user can start performance monitoring on one or more subsets of counters for each TP; it is not possible
to start individual performance counters.
Near end performance monitoring events are:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

266/396

Background Block Error (BBE): A BBE counter measures the number of error blocks, which do not
occur as part of an SES.

Error Second (ES): A one second period with one or more error blocks or with a defect.

Severely Error Second (SES): A one second period which contains > 30% of error blocks, or at
least one Severely Disturbed Period (SDP). An SES is also counted as an ES.

Near End Unavailable Second (NEUAS): An Unavailable Second is a second, which is part of the
Unavailable Time.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The corresponding Far End (FE) performance monitoring events are:

Far End Background Block Error (FEBBE): A far end error block, which does not occur as part of
an FESES.

Far End Error Second (FEES): Identifies, at a terminal, a one second period with one or more error
blocks or with a defect, which were received by the Far End Terminal.

Far End Severely Error Second (FESES): Identifies, at a terminal, a one second period which
contains > 30% of error blocks, or at least one Severely Disturbed Period (SDP) which was
received/detected by the Far End Terminal. An FESES is counted as an FEE.

Far End Unavailable Second (FEUAS): An Unavailable Second is a second, which is part of the
Unavailable Time at the far end.

The Termination Point (TP) type determines which performance monitoring events can be counted:
-

SDH TPs
Both near end and far end counters are supported in receive direction of the signal for all SDH path
layers and for the multiplex section layer. For the regenerator section, no far end information is
transmitted and, therefore, only near end counting is supported.

PDH TPs
Only near end counters are supported in receive direction for all PDH path layers.

Further definitions:

Error Block (EB): A block in which one or more bits associated with the block are erroneous.

Remote Error Indicator (REI) [formerly Far End Block Error (FEBE)]: Identifies, at a terminal, the
count of error blocks that were received by the far end terminal.

Remote Defect Indicator (RDI) [formerly Far End Receive Failure (FERF)]: indicates to a terminal
that the far end terminal has detected an incoming failure.

Unavailable Time (UAT): A period of unavailable time begins at the onset of 10 consecutive SES
events. These 10 seconds are considered to be part of unavailable time. A new period of available
time begins at the onset of 10 consecutive non-SES events.

Pointer Justification Event (PJE): A PJE is an inversion of I- or D- bits of the pointer, together with
an increment or decrement of the pointer value to signify a frequency justification.

Out of Frame Second (OFS): An AFS is defined as a second in which one or more out of frame
events have occurred. This event is identified by the A1/A2 byte of the SDH Frame.
The counting of OFS is sonly supported for the regenerator section termination. Please note that this
counter is deprecated by ETSI and will be removed from international standards.

17.1.3 Far End (FE) and Near End (NE) Performance Counting
Far end performance monitoring parameters are derived from Remote Defect Indicators (RDI) and Remote
Error Indicators (REI).
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

267/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 228.

Far End Performance Monitoring Principles

At Node A, the near end information represents the performance of the unidirectional section/path
from B to A, while the far end information represents the performance of the unidirectional
section/path from A to B.

At Node B, the near end information represents the performance of the unidirectional section/path
from A to B, while the far end information represents the performance of the unidirectional
section/path from B to A.

Near end performance data at Node A and far end performance data at Node B correspond as long as
neither direction is disturbed, and vice versa.
In compliance with ETSI and ITU-T standards, far end errors cannot be counted in the case of near end
failures.
17.1.4 Bidirectional Counting (24 h Bi) for QoS
As specified in G.826, G.784 and ETSI 300417, the bidirectional PM collection for Quality of Service has
been supported by combining the information on each direction of transport to assess a single unavailability
state: the bidirectional path is in the unavailable state if either one or both directions are in the unavailable
state.
PM data are collected by a single UAS plus two sets of three event counters (BEE, ES, SES) for NE-PM and
FE-PM respectively. When the path transports unidirectional payload just the four counters for the NE-PM
are activated (BEE, ES, SES and UAS). Data collection is performed only on 24 hours registers and the NE
maintains a buffer of two registers: the 24hours current registers and the historical one.
17.1.5 End to End (e-e 24h) Performance Counting

VCn trails can be monitored in intermediate node through the activation of performance monitoring
process on Monitoring function.
As the trails are often responsible of the end-to-end customer service, the end-to-end monitoring can be
requested provide monitoring for Quality of Service purposes and, in addition, for network Maintenance
applications.
If SNCP is configured the Quality of Service collection have to be enable in the monitoring functions after the
matrix.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

268/396

End to end monitoring is achieved by activation of Performance monitoring on the two direction of path and
using far-end primitives. This process can be unidirectional (for Monitoring) or bidirectional process (for QoS).
In case of unidirectional process one direction can be monitored end to end and both 15minute and 24h
collection can be activate 15min./24H FE_BBE_, FE-ES, FE-SES, FE-UAS on incoming or egress signal
depending of the POM is enable. The TCA are also evaluated in both 15-minute and 24H counters.
The bidirectional process need the presence on the two Monitoring functions in the two directions in one NE
and among the two monitoring function a 24 hour collection can be activated with the collection of
incFE_BBE, incFE-ES, incFE-SES, UAS, eFE-BBE, eFE-es, eFE-SES.
17.1.6 Performance Monitoring on AU-PJE
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

AU PJE (Administrative unit point justification event) is an optional parameters request in G.784.
For AU PJE counters, the positive and negative PJE shall be counted separately on one selectable AU
within an STM-N signal, after the AU has been resynchronized to the local clock. Refer to G.783
The number of positive and negative outgoing PJE per second are collected in 15 minutes and 24 H
counters. A history of 16 x 15minutes counters and 2 x 24H are stored in the NE for each AU selected.
No Threshold crossing mechanism is supported on AU-PJE counters.
17.1.7 Tandem Connection Termination (TCT) and Monitoring (TCM)
TCM allows monitoring within the operator domain. The quality within the operator's on domain can be
proven regardless of the received quality of the signal at the entry point of the network. At the input point the
reference value is set to zero by using the TCM feature.
Tandem Connection Monitoring is applicable to VC-4-nc (n=1,4,16...), VC-4, VC-3 and VC-12 layers.
TCM provides:
-

Incoming error count (IEC)

TC_REI to indicate error blocks within the TC to the far end;

OEI to indicate error blocks of the engrossing VC-n;

TC_API as access point identifier complying with generic 16-byte string format;

TC_RDI indicating to the far end that defects have been detected within the TC at the near end TC sink;

17.1.8 Performance Monitoring on 2 Mbit/s ISDNPRA


The feature provides PM data collection at the 2 Mbit/s ISDNPRA terminations.
The performance monitoring capabilities (applied on p12Mon TP) support both the standard data collection
modes:
G. 826 bidirectional for QoS
M2120 unidirectional nearend / farend for maintenance
17.1.9 Performance Data Collection
Near end and far end performance-monitoring events are counted over fixed monitoring periods of 15
minutes and 24 hours.
The 24-hour monitoring periods start at 00: 00 (UTC) and the 15-minute monitoring periods start at xx: oo,
xx : 30 and xx : 45.
Performance monitoring can be enable and disables at any time during a monitoring period. An entity of all
near end or far end performance monitoring events is always counted, it is not possible to start individual
performance counters (e.g. SES only). BBE, ES and SES counting is stopped during Unavailable Time.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

269/396

Event Counting
The performance events (e.g. SES) are counted in a counter per event. These counters are called the
current register. At the end of the monitoring period, the contents of the current registers are transferred to
the first of the recent registers, together with a time stamp to identify the period (including the day). Time
stamping is performed using UTC (as for all alarms). After that, the current register is reset. It is also possible
to reset an individual current register manually.
Suspect Flag
A suspect interval flag is set as an indication that the data of the corresponding register may be either
incomplete or invalid.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Zero Suppression
Zero suppression is a basic mechanism to remove irrelevant PM information and to reduce the amount of
PM reports in the system. A PM report is suppressed and hence no history record is created by the entity,
which is responsible for PM reporting when all of the following conditions are true for the monitoring period:
-

An interval is error-free (all PM counter values are zero)

- PM was enable enabled during the entire monitoring interval (the elapsed time equals its nominal value,
i.e. 900 for 15 min. and 86400 for 24 h<9.
-

PM was running properly (the suspect interval flag is not set)

By default, zero suppression is active for all PM enabled TPs. The number of suppressed intervals is
indicated.
17.1.10 Data Collection
N.B. PM data is not counted on boards that were plugged out at the moment of enabling data collection (see
PM Configuration dialog). Nevertheless, PM data is counted on boards that were plugged in at the moment
of enabling data collection, but were plugged out and back in some time during data collection.
Performance Monitoring can be started at any time.
As soon as Performance Monitoring is started on the Craft Terminal, current PM data is collected on the I/O
boards, incrementing the performance counters each time an error is detected.
The performance data counted is evaluated every quarter of an hour or every 24 hours and stored there in a
history record.
When the user disables the monitoring of a TP within the first 10 minutes of a 15-minute period, it is possible
that have still not been received the PM data of the previous monitoring interval.
Since PM data is not stored after monitoring is disabled, the PM data of the previous interval is lost in this
case.
If equipment or line protection switching occurs during a counting interval, the NE does not provide complete
performance measurement for the protected TPs.
Only the period between the last switch and the end of the counting window is counted.
The interval is marked for suspect data and the elapsed time indicates the length of the measured period.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

270/396

17.1.11 Performance Monitoring History


Performance monitoring history data is necessary to assess the recent performance of transmission system.
Such information can be used to sectionalize faults and to locate the source of intermittent errors.
History data, in the form of performance monitoring event counts, is stored in registers in the NE. All the
history registers are time stamped.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In compliance with ETSI and ITU-T standards, the history registers operate as follows:
The history data is contained in a stack of registers. There are sixteen 15-minute period registers and one
24-hour period registers per monitored event. These registers are called the recent registers. At the end of
each monitoring period, the contents of the current registers are moved the first of the recent registers. When
all recent registers are full, the oldest information is discarded.
17.1.12 Thresholds
For quality supervision purposes, the recorded errors through the performance counters can be compared to
threshold levels. If a counter value has crossed a threshold level, a Threshold Crossing Alarm (TCA) is
transmitted to the alarm manager.
The threshold values are defined in threshold tables together with a severity and a flag indicating whether
crossing this value should be notified by an alarm and logged or only stored in the current problem list. The
user can modify and delete such tables.
Different thresholds can be assigned for near end and far end and for granularity of 15 minutes and 24 hours.
The TCA only reports the value of the counter, which has crossed the threshold; it does not provide a
complete set of all counters. Therefore, the user has to explicitly retrieve all current performance data after
receiving the alarm. The user can retrieve this information from the Current Performance Management Data
Dialog..
Two thresholds mechanism are supported:
- For 24-hour (implicit clearance) monitoring periods, one threshold value is defined: if the event count
reaches or exceeds the threshold value during the monitoring period, a TCA is generated. To clear a TCA,
the alarm must be manually acknowledged by the user.
- For 15-minute (explicit clearance) monitoring periods, two threshold values (set, reset) are defined: a TCA
is generated during the monitoring period when the event count reaches or exceeds the set threshold value
the first time. This TCA is automatically cleared by the system at the end of the following monitoring period in
which the event count is less than or equal to the reset threshold value and there was neither an unavailable
nor a suspect period during this monitoring period.
The following limitations apply for explicit clearance:

The value of the low threshold is fixed to "0" (only a single threshold is provided by a threshold table).

An SES threshold crossing is cleared at the end of the interval if no unavailability was detected and
SES had not reached the low threshold (low threshold equal to 0).

Even in case of a suspect interval the TCA is cleared if no unavailability was detected and the low
threshold had not been reached.

Additionally an explicit clearance of TCAs for all granularity periods is executed if one of the following events
occurs during the current interval:

ED

Deletion of the current data instance,

Resetting of counters,

Increased thresholds (higher than current value of counters) (only for 24 h)

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

271/396

17.2 Configuration ( SDH Port )


Use menu item Add TP to display a special TP in the Transmission menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the TP and open the PM Configuration dialog by clicking on the menu item Configure Monitoring.

Figure 229.

Configure Monitoring.

This "PM Configuration" dialog serves as the main interface to all PM services. Every configuration
of all monitoring intervals is defined using this dialog.
It is possible to access the same "PM Configuration" dialog selecting a TP in the "Port view" and opening the
same Performance > Configure Monitoring option in the Port pull down menu.
N.B. To configure PM for au4CTPs and tuxCTPs, Path Overhead Monitoring (POM) or Supervised
Unequipped Termination (SUT, not supported) or Tandem Connection (TCT, TCM) must be created first.
The PM Configuration dialog is designed as a notebook consisting of a text field, to identify the selected TP,
and page labels.
The selected TP is indicated in the first box at the top of the screen: TP Identifier.
In case of au4CTP and tuxCTPs and VcxCTP, the PM Configuration dialog also contains an option button
showing the configured POM and SUT options as follow.
-

PathOverhMon After Matrix

PathOverhMon Before Matrix

TP (Performance is made on AU-PJE)

TCM After Matrix

TCM Before Matrix

TCT Bidirectional After Matrix

TCT Bidirectional Before Matrix

When more than one of the above options is chosen, a Question dialog box is displayed; click on Cancel to
continue or OK to interrupt any action.
N.B. As long as the PM Configuration dialog is open, a modified POM/SUT/TC configuration is not
automatically recognized and displayed. This may lead to rejections or confirmations of forbidden PM

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

272/396

configuration. Therefore make sure to reopen the PM Configuration dialog each time the POM/SUT
configuration is changed.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Each page label presents a range of parameters for one near end or far end granularity period (15 min. or 24
h), which together form a dataset. To select a special page label, click on the top part of the label:

NE15, near end 15 minutes page

NE24, near end 24 hours page

FE15, far end 15 minutes page

FE24, far end 24 hours page

24hBi, near and far end 24 hours page bidirectional (UAS is the sum of far end near end)

e-e-24h, end to end 24 hours page (enable only on HPOM)

Each dataset has to be configured independently. For AU-4 CTP and TU-x CTP the highest criteria are POM
and SUT. I.e. select the POM or SUT option first and then configure the different associated data sets.
Confirm the configuration with Apply before you continue with a different POM or SUT option.

Figure 230.

ED

03

PM Configuration Dialog (example)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

273/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 231.

PM question dialog box (example)

Activate any item within the page label by selecting the respective radio button.

Mode
Data Collection
Select this button to activate performance monitoring. Disabling Data Collection leads to clearance of
the current and all history data of this entity.
Create History Data
If this item is selected, history data collection is performed in the selected entity for the
corresponding TP.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

274/396

Note that on disabling this mode item, no history data is available. Nevertheless, datasets collected
prior to deactivation are not cleared and are displayed after re-enabling the item, as long as the
number of displayed datasets does not exceed 16 for 15 min. granularity.
Lock Data Collection. Not supported
If Lock is selected, PM remains enabled but data collection is stopped. All history performance data
remain available. All current values are set to zero.

EML OS Monitoring (only accessible from SH)


Not available for Craft Terminal.

Notifications

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

UAT (only available for 24 h granularity)


For 24 h granularity, UAT (Unavailable Time) notifications are created if enabled. This notification
results in an UAT alarm in the Alarm Surveillance.
N.B. This parameter can only be selected during creation and cannot be subsequently modified.
Suppress Additional Threshold
Disabled: the alarm is generated every time the value exceed the upper threshold (value up).
Enabled: after a first alarm generation, the alarm is generated again when the value exceeds the
upper threshold (value up) after the lower threshold (value down) has been exceeded.

Threshold Table
Attach a threshold table to the selected TP. Only assign threshold tables that match the granularity
period of the datasets (i.e. a 15 min. threshold table must not be assigned to a 24 h dataset).
Otherwise the Transmission view is blocked and only released by closing and reopening the PM
Configuration window and the Transmission view.
Click on button Attach... to open the PM Threshold Table Select dialog (see) and configure the
threshold table (see Chapter on page).
Select button Remove to disassociate the threshold table from the entity.
N.B. A threshold table can only be attached if Data Collection is enabled.

Set Alarm Severity UAT


ASAP Id
This field shows the label of the ASAP pointer assigned to the UAT alarm
Set ASAP
Allows to set new ASAP pointer for the UAT alarm. The Set ASAP button opens the window
displayed.

Confirm the configuration with the button Apply before closing the dialog. Otherwise the configuration is lost.

17.3 Performance Monitoring on ETHRNET port


Performance Monitoring on Ethernet port, are described in the following paragraph:
Paragraph 17.8 Configuration (Ethernet port) deals with the configuration of performance monitoring.
Paragraph 17.9 Display Current Data (Ethernet port) deals with displaying current performance data.
Paragraph 17.10 Display History Data (Ethernet port) deals with displaying history performance data.
An Ethernet link can be defined between two 10/100 Ethernet interfaces, or between two Gb Ethernet
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

275/396

interfaces, or also between a Fast Ethernet and a Gb Ethernet interface.


At the terminations of Ethernet link, it s possible to monitor the Ethernet frames and to collect information
about the Ethernet traffic by means of some counters.
Definitions of incoming and outgoing counter direction
[1] Incoming (network centric view): it refers to the direction starting from Ethernet domain toward SDH
domain (see Figure 232.). The traffic arrives to the board from an Ethernet link and goes out from an SDH
link.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

[2] Outgoing (network centric view): it refers to the direction starting from SDH domain toward Ethernet
domain (see Figure 232.). The traffic arrives to the board from an SDH link and goes out from an
Ethernet link.

Figure 232.

Counter directionality: network centric view

17.3.1 Overview
Ethernet counters can be distinguished from different points of view as depicted in Figure 230.
They can be:
Physical interface counters
aggregate counters
flow counters
At physical interface level, the working status of transceiver is controlled.
At aggregate level, all Ethernet traffics passing through the same port can be viewed as an aggregate.
At flow level, each single flow is managed.
Besides this classification, some counters can be of Quality of Service, others only of maintenance.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

276/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 233.

Counter subdivision

17.3.2 Ethernet physical interface counters


Ethernet physical interface counters are used to test Ethernet interface working state.
They are:
Symbol Error : for an interface operating at 100Mb/s, the number of times there was as invalid data symbol
when a valid carrier was present. For an interface operating in fullduplex mode at 1000 Mb/s, the number of
times the receiving media is nonidle carrier event for a period of time equal or greater than min Frame Size,
and during which there was at least one occurrence of an event that causes the PHY to indicate Data
reception error on the GMII. The count represented by an instance of this object is incremented at most once
per carrier event, even if multiple symbol errors occur during the carrier event. This count does not increment
if a collision is present.
Media Available Exits : number of times that if Mau Media Available for this MAU instance leaves the state
available. Discontinuities in the value of this counter can occur at reinitialization of the management system,
and at other times as indicated by the value of if Counter Discontinuity Time.
Jabber State : number of times that mau Jabber State for this MAU instance enters the state jabbering.
This counter will always indicate zero for MAUs of type dot1MauTypeAUI and those of speeds above
10Mbps. Discontinuities in the value of this counter can occur at reinitialization of the management system,
and at other times as indicated by the value if Counter Discontinuity Time.
False Carrier: number of false carrier events during IDLE in 100BASEX and 1000BASEX links.
For all other MAU types, this counter will always indicate zero. This counter does not increment at the
symbol rate. It can increment after a valid carrier completion at a maximum rate of once per 100 ms for
100BASEX and once per 10s for 1000BASEX until the next Carrier Event. Discontinuities in the value of
this counter can occur at reinitialization of the management system, and at other times as indicated by the
value of if Counter Discontinuity Time.
They are only maintenance counters.
17.3.3 Aggregate counter
Aggregate counters count frames that pass through the same port. Single flows are hidden inside the
aggregate.
Aggregate counters are (refer to :
TRCO (Total Received Correct Octets): total number of octets of Ethernet frames received correctly by the
Virtual Ethernet Interface , including Ethernet header characters.
TRCF (Total Received Correct Frames): total number of Ethernet frames received correctly by the Virtual
Ethernet Interface

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

277/396

TTO (Total Transmitted Octets): total number of octets of Ethernet frames transmitted out by the Virtual
Ethernet Interface , including Ethernet header characters.
TTF (Total Transmitted Frames): total number of Ethernet frames transmitted out by the Virtual Ethernet
Interface
TDF (Total Discarded Frames): total number of Ethernet frames which were chosen to be discarded due to
buffer congestion. TRSEF (Total Received Service Errored frames): it is the sum of three contributions.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

They are Quality of Service counters.

Figure 234.

Ethernet aggregate counter

17.3.4 Flow counter


Flow frames can be coloured Red Green or Yellow depending if flow is in compliance or not with SLA
parameters.
So flow counters definitions take in consideration frames colours.
Counters definitions are:
TRCO_G (Total Received Correct Green Octets): total number of octets of green Ethernet frames received
correctly, including Ethernet header characters.
TRCF_G (Total Received Correct Green Frames): total number of green Ethernet frames received
correctly.
TRCO_Y (Total Received Correct Yellow Octets): total number of octets of yellow Ethernet frames
received correctly, including Ethernet header characters.
TRCF_Y (Total Received Correct Yellow Frames): total number of yellow Ethernet frames received
correctly
TRCO_R (Total Received Correct Red Octets): total number of octets of red Ethernet frames received
correctly, including Ethernet header characters.
TRCF_R (Total Received Correct Red Frames): total number of red Ethernet frames received correctly.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

278/396

TDF_G (Total Discarded Green Frames): total number of green Ethernet frames which were chosen to be
discarded due to buffer congestion.
TDF_Y (Total Discarded Yellow Frames): total number of yellow Ethernet frames which were chosen to be
discarded due to buffer congestion.
TTO_G (Total Transmitted Green Octets): total number of octets of green Ethernet frames transmitted out,
including Ethernet header characters.
TTF_G (Total Transmitted Green Frames): total number of green Ethernet frames transmitted out.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

TTO_Y (Total Transmitted Yellow Octets): total number of octets of yellow Ethernet frames transmitted out,
including Ethernet header characters.
TTF_Y (Total Transmitted Yellow Frames): total number of yellow Ethernet frames transmitted out.

17.4 Display Current Data ( SDH Port )


Use menu item Add TP to display a special TP in the Transmission view.
Select the TP and open the Current PM Data dialog by clicking on the menu item Display Current Data.

Figure 235.

Display Current Data view

This "Current PM Data" dialog serves to show the results and status of the Performance Monitoring
counters.
It is possible to access the same "Current PM Data" dialog selecting a TP in the "Port view" and opening the
same Performance > Display Current Data option in the Port pull down menu.
The Current PM Data dialog is designed as a notebook consisting of a text field, to identify the selected TP,
and page labels.
The selected TP is indicated in the first box at the top of the screen: TP Identifier.
In case of au4CTP and tux CTPs, the Current PM Data dialog also contains an option button showing the
configured POM and SUT options to display as follow:
-

Path Overh Mon After Matrix

Path Overh Mon Before Matrix

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

279/396

TP (Performance is made on AU-PJE)

TCM After Matrix

TCM Before Matrix

TCT Bidirectional After Matrix

TCT Bidirectional Before Matrix

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Each page label presents a range of parameters for one "near end and far end" granularity period (15min. or
24h) which together form a dataset. To select a special page label, click on the top part of the label:

15 min, near end and far end 15 minutes page

24 h, near end and far end 24 hours page

24hBi, far end 24 hours page bidirectional (UAS is the sum of far end and near end)

e-e 24h, end to end 24 hours page (enable only on HPOM)

All datasets available, which are related to the selected TP and recorded in the current monitoring interval,
are displayed in this dialog.
The following items are indicated for each entity:

Administrative State
Indicates whether the PM collection is locked for the local user or not.

Operational State
Indicates whether PM is enabled or disabled.

Suspect Data
Indicates if collection errors occurred during the collection period.

Threshold Table

Indicates which threshold table is assigned to the entity.

Current Problem List


Indicates current UAT ("Unavailable") and TCA ("Threshold Crossed") alarms.
N.B. The entry "Unavailable Threshold Crossed" indicates, that both alarms are active. Since the text
field is too small to display the full text at a time, use the cursor to scroll the text field in this case.

Elapsed Time
Indicates the time, which has elapsed since the monitoring interval was started. This information tells
the user whether the data collection covers the whole period.

At the bottom the PM results are listed.


Reset button is used to restart the counting period. Two buttons are present for near-end and far-end
periods.
Press the Refresh button to update the window contents and display the latest data.
Using the Print button, PM data can be saved to a file or printed on paper.
N.B. If no printer is installed, there is no error message displayed to indicate this.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

280/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 236.

Current PM Data Dialog (example)

17.5 Display History Data ( SDH Port )


Use menu item Add TP to display a special TP in the Transmission view.
Select the TP and open the PM History Data dialog by clicking on the menu item Display History Data.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

281/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 237.

PM History Data view

This "PM History Data" dialog serves to show stored Performance Monitoring counting.
It is possible to access the same "PM History Data" dialog selecting a TP in the "Port view" and opening the
same Performance > Display History Data option in the Port pull down menu.
The PM History Data dialog is designed as a notebook consisting of a text field, to identify the selected TP,
and page labels.
The selected TP is indicated in the first box at the top of the screen: TP Identifier.
In case of au4CTP and tuxCTPs VCxCTPs, the PM History Data dialog also contains a cascading menu
that allows choosing the POM and SUT options to display follow:
-

PathOverhMon After Matrix

PathOverhMon Before Matrix

TP (Performance is made on AU-PJE)

TCM After Matrix

TCM Before Matrix

TCT Bidirectional After Matrix

TCT Bidirectional Before Matrix

Each page label presents a range of parameters for one "near end and far end" granularity period (15min.,
24h, 24h bidirectional). To select a special page label, click on the top part of the label.
All available datasets (entities), which are related to the selected TP, are displayed in the table:

15 min, near end and far end 15 minutes page

24 h, near end and far end 24 hours page

24hBi, far end 24 hours page bidirectional (UAS is the sum of far end and near end)

e-e 24h, end to end 24 hours page (enable only on HPOM)

The PM data is displayed containing information concerning:


ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

282/396

Interval End Time


In the format dd.mm.yyyy hh:mm:ss.

The number of recorded events concerning an entity is divided into near end and far end data

Elapsed Time
Indicating whether the data collection was complete.

Susp

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Indicating suspect data where collection errors occurred during the collection period.
In case of 15 min. entities, a maximum of 16 datasets can be displayed simultaneously for each counter; the
24h entities display a maximum of one dataset. The user cannot change these figures.
If the limit of 16 datasets for 15 min. granularity and 3 datasets for 24 h granularity is reached, the oldest set
in the list is cleared when the next data set arrives.
Using the Print button, PM data can be saved to a file or printed on paper.
N.B. If no printer is installed, there is no error message displayed to indicate this.

Figure 238.

ED

03

PM History Data Dialog (example)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

283/396

17.6 PM Threshold Table Selection ( SDH Port )

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The PM Threshold Table Select dialog pops up if the Attach button is clicked in the PM Configuration
dialog.

Figure 239.

PM Configuration dialog

In addition, this dialog can be accessed using the Configuration menu:


N.B. Do not open several dialogs at the same time using both possibilities. Since those dialogs are not
synchronized, they could display different contents.
The dialog presents a list of existing threshold tables.
The tables are individually indicated with a number.
Each table is dedicated to specific entities, as reported in each table can be modified according the operator
selections.
The filtering criteria are not operative.
The user can perform the following actions:

Create / Modify / Display a threshold table.

Delete an existing threshold table


Mark the table in the list and click on the Delete button.
Note that a threshold table cannot be deleted if it is attached to a PM entity. An error message
informs the user of this situation.

Attach the selected threshold table to a TP entity. It is only available entering from the PM
Configuration dialog.

The user has to close the dialog explicitly by clicking on the button Close.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

284/396

Figure 240.

ED

03
PM Threshold Table Select

SC.3: NE MANAGEMENT

3AL 98253 ADAA

285/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Table 7. Threshold table entities association


N

Layer

TPs ASSOCIATED

Granularity

STM4

RS

15 minutes

2
3
4

STM4
STM1
STM1

RS
RS
RS

24 hours
15 minutes
24 hours

5
6
7
8

STM4
STM4
STM1
STM1

MS NE / FE
MS NE / FE
MS NE / FE
MS NE / FE

15 minutes
24 hours
15 minutes
24 hours

9
10
11
12
13
14

VC4
VC4
VC3
VC3
VC12
VC12

Path Termination NE / FE
Path Termination NE / FE
Path Termination NE / FE
Path Termination NE / FE
Path Termination NE / FE
Path Termination NE / FE

15 minutes
24 hours
15 minutes
24 hours
15 minutes
24 hours

After the activation of a PM on a TP, it will be signaled in the Port view and in the Transmission view as for
the following figures:

Figure 241.

Figure 242.

PM Port View

PM Transmission View

17.7 PM Threshold Table Creation / Modification / Display ( SDH Port )


17.7.1 Creation
The PM Threshold Table Create dialog pops up when the Create button is clicked in the PM Threshold
Table Selection dialog.
Carry out the following steps to create a threshold table:
1) Enter the table name in input field Name.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

286/396

Leading and succession blanks are ignored. Leaving the input field blank or entering only blanks is not
allowed and rejected.
2) Select a Granularity of 15 min. or 24 h for the entity.
3) Enter the set (Value Up) and the reset (Value Down) threshold values. Node that the reset value if
supported, will be available with 15 min. monitoring periods.
Table 1 shows the maximum performance monitoring event values.
The respective value is automatically reset to the maximum if a larger figure is entered.
4) Select the alarm Severity for each PM attribute in case a threshold is crossed.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

5) Disable Send notification if no notification message should be sent in the case of a crossed threshold.
6) Confirm the entries with Apply to create the threshold table. A number of threshold tables can be created
from the same window.
Explicitly close the window with button Close.

Figure 243.

ED

03

Create PM Threshold Table

SC.3: NE MANAGEMENT
3AL 98253 ADAA

287/396

17.7.2 Modification
The PM Threshold Table Modify dialog (see) pops up if a threshold table is selected in the PM Threshold
Table Selection dialog (see) and the Modify button is clicked.
Carry out the following steps to modify a threshold table:
1) Modify the upper threshold value (Value Up) and the lower value (Value down)
Table 1. Shows the allowed maximum performance parameter values.
2) Modify the alarm Severity for each PM attribute in case a threshold is crossed.
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization.

3) Disable Send notification if no notification message should be sent in the case of a crossed threshold.
Note that the Name (really "number") cannot be changed.
4) Confirm the modifications with Apply.
5) To modify more than one threshold table, do not close the dialog, but select the next threshold table in the
PM Threshold Table Selection dialog and press the Modify button (see).
Explicitly close the dialog with button Close.
17.7.3 Display
The PM Threshold Table Display dialog pops up if a threshold table is selected in the PM Threshold Table
Selection dialog and the Display button is clicked.
Refer to the previous chapter for a description of the attribute values and types.
Table 8. Maximum Performance Parameter Values
Performance Parameter

Max. Value for 15-min period Max. Value for 24-h period

BBE, FEBBE on STM-4

8,639,100

829,353,600

BBE, FEBBE on STM-1

2,159,100

207,273,600

BBE, FEBBE on all the other board

539,100

51,753,600

OFS, ES, UAS, FEES,

900

86,400

SES, FESES

810

78,760

PJC high, PJC low

1,800,000

172,800,000

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

288/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 244.

Modify PM Threshold Table

17.8 Configuration (Ethernet port)


Use menu item Add TP to display a special TP in the Transmission menu.
Select the TP (Gmau) and open the PM Configuration dialog (see Figure 245.) by clicking on the menu item
Transmission >Performance >Configure Performance Monitoring.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

289/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 245.

PM Configuration dialog

The Create Ethernet Counter window is opened

Figure 246.

Create Ethernet counter

In that dialog the operator will be allowed to create/delete the current Data by checking/unchecking the
corresponding checkbox for the incoming and outgoing direction.

17.9 Display current Data (Ethernet port)


Use menu item Add TP to display a special TP in the Transmission view.
Select the TP and open the Current PM Data dialog (see Figure 247.) by clicking on the menu item
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

290/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Display Current Data.

Figure 247.

Display Current Data

This Current PM Data allows the operator to send a request in order to retrieve the maintenance counters.
The layout of the dialog maintenance counters is depicted in Figure 248.
At startup the dialog displays an empty table; the dialog allows to choose the polling time and how many
times the action will be done; the default values for those entries are 0 for polling time and 1 for number of
retries, with that default configuration if the Start polling button allows to perform the configured request. If
the number of retries is bigger than 1, several actions are performed on the NE.
During the polling interval the label of the button Start polling will be changed to Stop polling, and for
every response arrived a row is added to the table. Every time the operators push the Start polling button
new lines will be added to the lines already present in the table.

Figure 248.
ED

03

Display current data

SC.3: NE MANAGEMENT
3AL 98253 ADAA

291/396

17.10 Display history Data (Ethernet port)


Use menu item Add TP to display a special TP in the Transmission view.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the TP (Gmau) and open the PM History Data dialog (see Figure 249.) by clicking on the menu item
Display History Data.

Figure 249.

PM History Data dialog

The menu item Display History Data will be opened:


In case of one hour history data, the showed values are the hourly historic data collected by NE.
If the NE has collected only one history data, the dialog shows directly counter values.
If the NE has collected more than one history data, the displayed counter values are calculated as a
difference from the older available history data value.
The older one will be added in the first line with the label and for each cell a tool tip will show the history
value received.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

292/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 250.

Display History Data

17.11 PM Overview
MSP Overview allows displaying performance overview.
Selecting the PM Overview option from the Configuration pull down menu figures below open.

Figure 251.

ED

03

PM Overview Menu item

SC.3: NE MANAGEMENT
3AL 98253 ADAA

293/396

Figure 252.

ED

03
PM Overview

SC.3: NE MANAGEMENT

3AL 98253 ADAA

294/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 253.

Add TP for PM Overview

You can click Add TP button to see the PM data about the selected TP. Like the figure below.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

295/396

Figure 254.

ED

03

PM Overview after add TP

SC.3: NE MANAGEMENT

3AL 98253 ADAA

296/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

18 Synchronization management
18.1 Introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All SDH NEs require timing in order to generate the necessary synchronization and frame phase reference
information. The timing can be provided by a source external to the NE or an internal timing generator. The
derived timing shall be used for all signals and interfaces in the NE that are related to the SDH frame
structure.
Follows a brief description of the heart of the NE clock known as the Synchronization Equipment Timing
Source (SETS).
It can be divided into 2 parts:

OSC: the internal oscillator.

SETG: the Synchronization Equipment Timing Generator.

The SETG is responsible for the generation of the external timing source for the Frame structure and the
clock, whilst the internal oscillator is useful only in the abnormal functioning "Free-running" mode that will be
explained later.
The simplified figure that follows represents the internal organization of the SETS.

Figure 255.

Internal organization of the SETS.

The internal sources (inputs) are:

T1: Reference obtained from incoming STM-N signals,

T2: Reference obtained from incoming 2 Mbit signals,

T3/T6: Reference obtained from an external incoming 2.048 MHz signal,

OSC: the internal oscillator.

The number of timing reference inputs depends on the configuration of the NE.
The external sources (outputs) are:

ED

T0: is the reference output signal for the clock and signal frames,

T4: is the reference output for the external equipment synchronization.


03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

297/396

T5: is the 2 Mbit/s reference output for the external equipment synchronization

Other reference points:

Y: is used for communication of Synchronization Status Message (SSM) between SETS and MST
functional blocks.

S15: is used to provide notifications and loss of incoming timing reference reporting to the
Synchronous Equipment Management Function (SEMF).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Selector A provides the capability to select timing reference from available T1 inputs, either automatically
based on the priority and quality level of the candidate sources (SSM algorithm), or manual as a result of
commands issued from the managing system.
Selector B is capable of selecting timing reference from T1, T2, or T3 inputs, according to the SSM
algorithm. The capability for manual selection of the timing source is also provided.
Selector C is only operated in manual mode, to switch between SETG output signal (T0) and a T1 timing
reference.
The squelch functions A and B mute the relevant timing references in the presence of failure condition, or
SSM threshold violation.
The choice of the timing reference is done in two ways:

Automatically:
Following a particular algorithm based on the quality and the priority of the incoming timing signals.
The automatic selection is based either on the priority of the incoming timing source (Priority
algorithm) or on the priority and the quality level of the incoming sources (SSM algorithm).

Manually:
Following an order from the Operator.

N.B. The Operator for each candidate-timing source determines the priority level. It is static information.
On the other hand, the quality of the source is dynamic information, dependant of the quality of the
reference clock generating the timing.
In an SDH signal frame, the quality of the timing source is located in the Section Overhead.
The SETG has 3 modes of operation:

Locked mode:
The SETG output is fully controlled by the external timing references (T1, T2 and T3).

Hold-Over mode:
The external timing reference is malfunctioning. The SETG during normal functioning stores
regularly the value of the external timing reference. In this case the SETG output is controlled by this
memorized value.

Free running mode:


This is not a normal operating mode. The external timing reference and the memorized timing
reference are malfunctioning. In this case the SETG output is controlled by the internal clock source.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

298/396

18.2 Synchronization Management

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The operations that can be done on the synchronization sources are the following:

Timing Source Configuration,

Protection Commands,

T0 Configuration,

T4 Configuration,

T0 TEST Configuration (not operative in current release)

SSU Configuration,

Remove Timing Reference,

Change T4<-> T5

Set T0 Equal T4

Change 2 MHz -> 2 Mbit (available only if T3 has been configured as timing source)

Remove T0 Equal T4,

Transmitted SSM Quality Configuration,

Frame Mode Configuration

Show Timing Source.

Before any other operation the synchronization view has to be displayed.


18.2.1 Displaying the Synchronization View
The synchronization view can be normally opened using the menu Views options.
Using menu options, select the Synchronization option from the Views pull down menu as shown in the
following figure.

Figure 256.

Obtaining the synchronization view

Selecting this menu option the synchronization representation will be displayed directly into the current
window instead of the current view. All the operations that can be done on the synchronization sources are
performed from this synchronization view.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

299/396

18.2.2 Synchronization View


The Synchronization view shows the external timing reference sources and the T0, T4 or T5, generation.
The selection is based on the SSM algorithm or on the priority of the incoming timing sources. Activating the
SSM algorithm implies that the selection of the source is before done on the quality criteria and then on the
priority criteria for sources at the same quality level.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

After selecting the Synchronization option from the Views menu the Synchronization View is visualized.

Figure 257.

Synchronization View Example

Synchronization View Description


The synchronization view provides two lists of allowable timing references:

One for T0 timing output; T0 list is always present;

One for T4 timing output; the presence of the T4 list is configurable using resource files.

T0 list contains:
- A timing reference associated to the Internal Oscillator timing source; it is always present and it cannot be
removed or redefined.
- 6 max timing reference for candidate inputs belonging to the allowable timing reference T1, T2 or T3/T6
configurable by the operator.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

300/396

T4 list contains:
- 6 timing reference for candidate inputs belonging to the allowable timing reference T1 configurable by the
operator.
The T0 and T4 lists are used for the management of reference timing source protection; a 1:n protection like
mechanism is used for the selection of the timing source from T0 (T4) list of the allowable timing references,
The protection system chooses the timing reference to generate the output T0 (T4) either automatically,
basing on the priority and quality level of the candidate sources according a selection algorithm or manually
under control of the managing system.
View elements description

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Here after, the basic component contained in the synchronization view are described:

Timing reference

Each allowable timing reference, , is represented by the graphical object displayed in the view; the timing
reference graphical object displays (with the exception of Internal Oscillator timing reference) the following
information (if the timing source has been declared by the user):
- The name of the selected timing source
- The status of the synchronization source: (lockout, manual switch, force switch, automatic switch, no
request, failure)
- The label of the quality level of the timing input source
- The priority of the timing input source
- 2 small boxes representing the SSF (Los) and DRIFT alarms detected on the timing source;
DRIFT means that the Frequency Offset between the external signal source and the internal clock is high
then the maximum tolerance value.
SSF means that the Server Signal Failure is sending a wrong reference signal to the NE.
In case of alarm indication the operator can select Show Timing Source to visualize the alarm detail.
In the timing reference graphical object associated to the Internal Oscillator the following information are
displayed:
- The name of the timing source: Internal Oscillator
- A small box representing the LOS alarm; the small box will be lighted up when all the selected timing
source are lost, indicating the Holdover or Free Running operation mode;
- A label field representing the abnormal clock operation modes, one of the following strings can be
displayed in the label field:
- Holdover, displayed when the clock operates in Holdover mode;
- Free running, displayed when the clock operates in Free Running mode;
- Empty string is displayed when the clock operates in Lock;
- A label "0" representing the priority of the Internal Oscillator

Selectors

Small ellipse are used to represent respectively:


- The selector A;
- The selector B;
- The selector C;

ED

Squelch Status
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

301/396

Boxes contained a label field are used to represent the squelch statuses T0/T4 and T4. The box displays the
configured quality level threshold and it is lighted up when the output-timing signal is inhibited.

Output Signal

An arrow and a label field are used to represent respectively:


- The output signal T0;
- He output signal T4/T5;

Line Type

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following different line type are used to link the output signals and the respective allowable timing
reference:
- A solid line between an output signal and an allowable timing reference means that timing reference is
currently used to generate that signal;
- A dashed line between an output signal and an allowable timing reference means that timing reference is
not currently in use as timing source but will act in the protecting role.
In the same way, a solid line between T0 signal and T4/T5 signal (or T0_Test signal) box is drawn when T0
signal is used to generate T4/T5
18.2.3 Timing Source Configuration
This functionality allows configuring the input synchronization sources and configuring or modifying the
timing source priority and quality.

Figure 258.

Synchronization Menu

The menu options are grey according to the current state of the dialogue box that the user can open.
Firstly select a synchronization source reference and after the Synchronization menu to open the
Synchronization Option List. Then select the Timing Source Configuration option from the cascading menu,
as shown in the above figure.
The following dialogue box is opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

302/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 259.

Timing source configuration for cross-Connect equipments

The Timing source configuration dialogue box which opens, displays the extracted quality of the selected
timing source. It permits to configure the following timing source information:

Quality level,

Priority level

Extracted Quality is the actual Rx quality retrieved from the signal received from the line.
Select an empty synch. Source reference and click on Timing Source Configuration and then on the Input
Source Choice. Figure below shows an example of the opened windows.
Following the TP Search procedure (rack, subrack, board, port) enter the physical board termination point
(TP) value; these TP are: EIS for electrical SDH port, OpS for optical SDH port.
This operation can be repeated for the entire available empty synch. Sources both for T0 clock and for T4
clock.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

303/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 260.

Synch. Source configuration for ADM equipment

Click on the Input Quality Configuration: the option button opens the option menu to select the desired
quality level.
Timing source may have, in increasing order, five quality levels: G.811, G.812T, G.812L, G.813, Q. Don't use
(where the highest quality level is G.811).
If Input Quality Configuration is set to a value other than "Extracted", Rx quality is forced to this value.
Click on the Priority: the option button opens the option menu to select the desired priority level.
The internal oscillator-timing source will have the lowest priority (priority=0) and its priority cannot be
changed. The other timing sources will have a priority of 1 to n.
Priority of 1 is the highest priority. Levels 6,...2 are intermediate levels between level 0 and 1, in increasing
order of priority (i.e. 0 6 5 4 3 2 1).
When the configuration of the timing source is completed, click on the OK push button to validate the choice
and close the dialogue box. The Cancel push button cancels the configuration and closes the dialogue box.
Positioning the mouse on the synch. Source box "Port#" test, the corresponding physical interface
denomination (rack-subrack-board-port) is written on the window bottom left.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

304/396

18.2.4 Synchronization Protection Commands

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select the timing reference from the synchronization view. Select the Synchronization pull down menu. You
can then select the Protection Commands to open the view. Menu options are grey. According to the
current state of the selected timing source.

Figure 261.

Lockout, Force and Manual commands

a) Invoke/Release Lockout: Locking or unlocking a timing source enables or disables the timing
source from being considered as a possible timing source for T0 or T4.
b) Invoke/Release Force and Manual Selection of Timing Source
General selection
A timing source can be selected manually or automatically. Furthermore, the selection of a particular
incoming timing source (except the internal oscillator) may be forced.
This selection is independent of the priority or quality of the timing source. If the timing source is lockout or
unavailable, this operation is impossible. A timing source is considered to be available if it is not lockout and
has not a failure condition or Priority level of 0.
Releasing terminates the forced switch mode or inhibiting the force selected timing source.
The manual selection option is only possible if the quality and priority of the selected timing source are
sufficient. Otherwise the automatic selection algorithm overrules the manual selection.
If the previously manual selected timing source becomes unavailable the automatic selection is activated.
The "Status" indication describes the current synch. status (No Request, Automatic Switch, Failure, ...)
N.B. The internal oscillator cannot be forced or manually selected.
From the dialogue box that opens, you can confirm or cancel the operation.
To perform or release a T0 or T4 lockout, forced or manual selection, the following operations have to be
done:

ED

Select the T0 or T4 source.

Click on the Synchronization menu.

Select the Protection Commands option then invoke/Release the Lockout, Forced or manual
Selection option.
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

305/396

Click on Apply in the displayed confirmation box.

Manual selection is not operative in the current release


18.2.5 Synchronization Configuration for T0/T4 and T4 squelch criteria
Select the available T0 or T4 synchronization sources and then the T0 or T4 Configuration... command.
This command permits to select/deselect the SSM algorithm, to set the wait time to restore and to enable the
revertive procedure if all these features are available.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In this NE revertive mode is hardware set, with fixed WTR.


In Revertive mode the internal selector A/B changes every time to the best reference clock with the highest
quality; on the same quality level basis the reference clock Source with the best priority will be selected. The
changing mechanism of the reference inputs is controlled by the wait time to restore: this time sets a delay
before to change the input source.
Selecting the T0 or T4 Configuration set the SSM algorithm and the Wait To Restore Time in the dialog box
upper part.
Click on the SSM Algorithm to select/deselect it.
Wait To Restore Time button and Revertive option button are disabled
Selecting T4 Configuration it is possible to set the T4 squelch criteria in the bottom dialog box.
This functionality allows configuring the external timing reference (T4) squelch criteria. The squelch function
mutes the relevant timing references in the presence of a failure condition.
Squelch may be forced by the Operator or according to squelch criteria, which consists in a choice of quality
level.
Different squelch criteria may be applied:

When T0 is selected to generate T4 (squelch B ): T0 may be squelched if all the allowable timing
references of Selector B have Quality Level lower than the programmable threshold.

When T1 is selected to generate T4 (squelch A ) :T1 may be squelched if T1 Quality Level is lower
than the programmable threshold or if it becomes unavailable.

The T0/T4 and T1/T4 squelch fields enables you to configure the quality level of the T0 or T4 timing source,
opening the relevant option menu.
When the configuration of T0/T4 Configuration is completed, click on the OK button to validate the choice
and close the dialogue box.
The T5 output field allows selecting the bit used (from #4 to #8) for SSM.
The Cancel push button cancels the configuration and closes the dialogue box.
The T4 squelch configuration dialogue box enables you to configure the quality level of the T4 timing
source.
Click on the T0: option button to open the option menu and select the desired quality level.
Click on the T4: option button to open the option menu and select the desired quality level.
The T4 Force Squelch enables you to activate the T4 forced squelch.
When the configuration of T0/T4 Configuration is completed, click on the OK push button to validate the
choice and close the dialogue box.
The Cancel push button cancels the configuration and closes the dialogue box.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

306/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 262.

Configuring the T0 or T4 SSM algorithm and the squelch criteria

18.2.6 SSU Configuration


The SSU configuration command allows either to configure the single NE or the NE with SSU. In the last
case the SSU quality has to be defined.
Selecting SSU Configuration from the Synchronization menu.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

307/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 263.

SSU Configuration

18.2.7 Remove Timing Reference


Select the synch. Source to remove and click on the Remove Timing Reference option. To remove the
selected source click on "OK" button of the confirmation message.

Figure 264.

ED

03

Synchronization source removing

SC.3: NE MANAGEMENT
3AL 98253 ADAA

308/396

To remove the selected source click on "OK" button of the confirmation message.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 265.

Synchronization source removing confirmation

18.2.8 Change T4 <-> T5


This Menu allows the change of the synchronization physical interface from 2Mhz (T4) to 2 Mbit/s (T5) and
vice versa
This menu is enabling only if the SERGI board is present in the subrack
Select Change T4 <-> T5 from the Synchronization.

Figure 266.

ED

03

Change T4 <-> T5 menu

SC.3: NE MANAGEMENT
3AL 98253 ADAA

309/396

A confirmation message appears

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 267.

Change T4 <-> T5 confirmation message

Click on ok to confirm; the new window display T5 inserted of T4

Figure 268.

ED

03

Change T4 <-> T5: command execution

SC.3: NE MANAGEMENT
3AL 98253 ADAA

310/396

18.2.9 Change 2MHz ->2Mbit


This menu is enabled only if the operator selects a protection unit, which has as source a 2 MHz or a 2
Mbit/s without traffic

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Select Change 2MHz -> 2Mbit from the Synchronization

Figure 269.

Change 2MHz -->2Mbit menu

A confirmation message appears

Figure 270.

Change 2MHz ->2Mbit confirmation message

Click on ok to confirm
The label of the protection unit will be changed depending on the kind of source selected:

ED

If the selected protection unit is a 2 MHz, then the label will be changed into 2Mbit/s.
03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

311/396

If the selected protection unit is a 2 Mbit/s, then the label will be changed into 2MHz

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 271.

ED

03

Change 2MHz -->2Mbit: command execution

SC.3: NE MANAGEMENT
3AL 98253 ADAA

312/396

18.2.10 Set and Remove T0 Equal T4

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To connect T0 internal synch. Select a synch. Source and click on Set T0 Equal T4 menu option. The
connection between T0/T4 will pass from a shaped to a continue line as in the example of Figure below.

Figure 272.

T4 equal T0 setting

To separate T4 from T0 click on the "Remove T0 Equal T4" menu option. The T0/T4 connection will become
shaped while the connection between T1/T4 will pass from a shaped to a continue line.
18.2.11 Transmission of SSM Quality Configuration
Select the T1 SDH Reference Source in the Synchronization View hence the Transmission SSM Quality
Configuration is enabled. This selection allows, with the Inserted option, to transmit the system internal T0
clock quality towards the external SDH interface. It is also possible to transmit different quality level selecting
a different value.
Click on Transmitted SSM Quality Configuration of the Synchronization menu option.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

313/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 273.

Transmission SSM Quality

This Transmission SSM Quality window can be also opened from any SDH boards. Select the Equipment
option of the View menu, then access the Board view> Port view> Physical Media> SDH Tx Quality
Configuration; it is also possible to open the window selecting the Transmission option of the View menu,
then access the Physical Media> SDH Tx Quality Configuration option.
In both cases select the MST block
18.2.12 Show Timing Source
Selecting any T1 or T2 Reference Source in the Synchronization View hence the Show Timing Source is
enabled. This selection allows analyzing
the input source considering its payload structure and the related alarms (Port view is presented) .
Click on Show Timing Source of the Synchronization menu option.

Figure 274.

ED

03

Timing Source Example

SC.3: NE MANAGEMENT
3AL 98253 ADAA

314/396

19 MS-SPRING MANAGEMENT
19.1 MS-SPRING introduction
Different MS-SPRING protections architectures are provided: 2-Fiber (Terrestrial), and 4-Fiber NPE
(Transoceanic).
See ITU-T Rec. G.841.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The description of the MS-SPRING protections is inserted in the Technical Handbook.


4 Fiber MS-SPRING is not operative in this release.

19.2 MS-SPRING connection configuration advices


In the following paragraphs 2-Fiber and NPE advices are reported, to follow before to implement the MSSPRing protection: there are some limitations concerning the aggregate types or the AU4s crossconnections to be considered.
19.2.1 2-Fiber MS-SPRING connection configuration advices
The following suggestions must be considered in the MS-SPRING connection configuration:

SNCP, 4 Fiber MS-SPRING and Aggregate MSP protection connections cannot be installed in a 2
Fiber MS-SPRING network. This leads to an unprotected connections installation.

AU4s from #9 to #16 don't have to be used for connections nor considered in any parameter of
"Squelching table" provisioning. Only AU4s from #1 to 8# must be used and configured for path
installation.

AU4 permutation (change of AU4 allocation) is not allowed. The AU4 allocated to pass-through in
HVC connections must be the same through the node.

AU4 cross connection Aggregate side, i.e. paths received from the Aggregate line and looped-back
to the (same) Aggregate line are not allowed.

Follow the "Squelching Table Configuration" in order to define the "Squelching Table HO" for East
and for West aggregates describing, for each connection installed, as Source Node, the Node
Identifier of the node generating the considered AU4 and as Destination Node, the Node Identifier
of the node terminating the AU4.

19.3 Operative sequence to configure MS-SPRING


In the following paragraphs 2-Fiber and NPE operative sequence to follow during configuration are inserted.
19.3.1 Operative sequence to configure 2-Fiber MS-SPRING
Next paragraphs lit the operative sequence according the type of produce to obtain.
-

Activation procedure
a. Create an MS-SPRING schema with WTR, Node Identifier, Ring map and the related Squelching
Table for each node of the ring, in the desired order. WTR Ring must be same in all the nodes.
b. In the Main dialog for MS-SPRing management select "ACTIVATE" in each node of the ring, in the
desired order. Consider that, in this step, "Default K byte West or East" detection by View Protection
Status Parameter (under MS-SPRing label -> " Protocol exception"), will occur on those Aggregate
of the activated nodes connected to the nodes just deactivated.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

315/396

c. Verify in the View Protection Status Parameter screen, at the end of the provisioning update, that all
the nodes of the ring are in "MS-SPRing activate" and "No request" state.
-

Deactivation procedure
a. In the Main dialog for MS-SPRing management select "DEACTIVATE" in each node of the ring.
Consider that, in this step, "Default K byte West or East" detection by View Protection Status
Parameter (under MS-SPRing label -> "Protocol exception"), will occur on those Aggregate of the
activated nodes connected to the nodes just deactivated.

b. In the Main dialog for MS-SPRIng management select "DELETE" in each node of the ring.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Removing a node
a. In the Manage ring Map view select the node and click on the "Remove Node" button
b. Modify the table in the Configure Squelch Table view according the new Ring Map.
c.

Opening the View Protection Status Parameter screen, send "Force Ring" command to both NE's
adjacent to the node to be removed.

d. Physical remove the node


e. Connect the fibers and send the "Release" command of the relevant "Force Ring" to both NE's
adjacent to the removed node.
-

Adding a node
a. In the Manage ring Map view insert the node in the selected position. Next nodes are automatically
shifted.
b. Modify the table in the Configure Squelch Table view according the new Ring Map.
c.

Opening the View Protection Status screen, send "Force Ring" command to both NE's adjacent to
the node to be added.

d. Physical add the node and configure with 2-Fiber MS-SPRING activated with the right configuration
(Ring Map, Squelching table, WTR, node Identifier).
e. Connect the fibers and send the "Release" command of the relevant "Force Ring" to both NE's
adjacent to the added node.

19.4 MS-SPRING Management


In the NE current release the NE supports the MS-SPRING protection as "Terrestrial architecture".
The Transoceanic application with 4-Fiber is not supported in current release.
For the 2-Fiber Terrestrial application a max. of 16 nodes are available.
The available tables permit to visualize for the same NE the architecture 2 x 2-Fiber.
Figure below shows the MSSPRing pull down menu.

Figure 275.

Display MSSPRing pull down menu

The first Main Dialog for MS-SPRing management option contains all the commands to configure and
manage the MS-SPRing.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

316/396

In any dialog box is present the Cancel or Close buttons. When the user clicks on these buttons the dialog
box will close without starting any operation.
19.4.1

MS-SPRing Main Configuration

Select the MS-SPRing pull down menu. Then select the Main Dialog for MS-SPRing management option
from the pull down menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The following dialogue box is displayed when no protection have been previously configured

Figure 276.

MS-SPRing Management dialog box

The only command available is Create. The name of Schema Selection in not editable but is fixed to "No
Schema".
Click on Create to start the MS-SPRing configuration. Figure below opens

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

317/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 277.

Creation Schema dialog box

The user can select the MS_SPRing Application and the Architecture types supported by the Network
Element.
Terrestrial MS-SPRing Application is a 2Fiber architecture.
Transoceanic MS-SPRing is a 4 Fiber architecture.(not supported in current relese)
The "Port Selection" depends on the Architecture type: if the architecture is a 2F MS-SPRing, the working
and protection port on each side is the same and the "Protecting West and East" fields are disabled (greyed).
If the architecture is a 4F MS-SPRing, the working and protection ports on each side are different.
The label r(xx)sr(y)sl(zz)port#(hh) where r=rack, sr=subrack, sl=slot give the position of the physical port. In
the same board it is generally possible to have different port numbers.
The OK button will start the selected operation. The cursor is displayed busy up to receiving a reply. Then
the dialog window will be closed. Figure below opens and all commands are now available.
The Holdoff Time command is not operative in current release.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

318/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 278.

Activated MS-SPRing Management

Click on Ring Map to configure the network node connection. Figure below opens

Figure 279.

Node Id and associated ring node position

The Ring Map sets the connection sequence of the nodes within the ring. The matrix represents up to 64
nodes for transoceanic application and up to 16 nodes for terrestrial application.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

319/396

Select Current Nodeld (it means the NE where the operator is acting) in the box and enable
Nodeld button (Id means Node Identifier)

Change

Select Available Nodeld in the pull down list ( 0 to 63 for transoceanic application, 0 to 15 for terrestrial
application) releasing the left mouse button or pushing the stepper arrows and enter keys to select the
Nodeld value.
This will be displayed in the Available Nodeld box then click on Add Node button.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Clicking on the Add Node button the selected "Ring position" will shift one step on the righ starting from "1"
position and in the "Nodeld" field the Available Nodeld values is inserted. In the same time the Available
Nodeld will be updated to a new value.
The default association for a four node node ring related to the fourth node (Nodeld=3; Ring Position=4) is
depicted in Figure below.

Figure 280.

Ring map configuration

Repeat the procedure for all nodes of the ring selecting the different NEs and edit the different Current
Nodeld value.
To remove a node, select the node and click on Remove Node button. The following Ring Position of the
nodes on the right decreases by one and the erased Nodeld is inserted into Available Nodeld, so it can be
assigned to other nodes.
The OK button will start the selected operation, displaying the busy cursor up to receiving the replay to the
actions. Then the dialog window will be closed.
Click on the WTR Time button. Figure below opens

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

320/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 281.

WTR dialog box

Click on the push mouse button on the p/down Seconds arrows to select the required delay for the relevant
WTR. The step value is 60 sec. The range value accepted is from 60 sec. to 900 sec. Click on OK to apply
the WTR Configuration.
WTR Time Span is used only for 4-fiber architecture; it is disable (grey) for 2 fiber architecture.
The same WTR Time Ring must be set on each Node of the ring.
19.4.2 Squelching table with 2 fiber Terrestrial applications
With a 2 fiber Terrestrial application can be selected the Squelching Table while with a 4 fiber
Transoceanic application can be selected the Ring Traffic
If the operator tries to select a different table a error message is visualized. Figure below shows the error
message visualized when is selected the Ring Traffic with a Terrestrial application.

Figure 282.

Example of error message

Click on Squelching Table to configure the AU4 (Au4#1 to AU4#8 for 2F Architecture) connection between
the different nodes. Figure below opens. The same opens clicking on Configure Squelch Table of the MSSPRing pull down menu.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

321/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 283.

Squelching table

When the window is opened for the first time the squelching table is N/A (not available) because the NE has
never been configured. Point the mouse on the matrix position and click on the right mouse button to open
the node list menu. Select the node identification number ( 0 to 15 ) from the available list using the slider or
the stepper arrows on the right scroll region.
19.4.2.1 Squelching table example

Figure 284.

ED

03

Example of a ring traffic

SC.3: NE MANAGEMENT
3AL 98253 ADAA

322/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The squelching table is applicable only for OH-VC signals.

Figure 285.

Figure 286.

ED

03

Connections of the ring

Squelching table of Node A, West side

SC.3: NE MANAGEMENT
3AL 98253 ADAA

323/396

ED

03
Figure 287.
Squelching table of Node A, East side

Figure 288.

Squelching table of Node B, West side

SC.3: NE MANAGEMENT

3AL 98253 ADAA

324/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

03
Figure 289.
Squelching table of Node B, East side

Figure 290.

Squelching table of Node C, West side

SC.3: NE MANAGEMENT

3AL 98253 ADAA

325/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

03
Figure 291.
Squelching table of Node C, East side

Figure 292.

Squelching table of Node D, West side

SC.3: NE MANAGEMENT

3AL 98253 ADAA

326/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 293.
19.4.3

Squelching table of Node D, East side

Activate, Deactivate and Delete commands

The Main Activates commands manage the MS-SPRing configuration. The MS-SPRing status can be Enable,
Active, Disable and Inactive.
After having configured the protection schema by means of the Create button, the status becomes Enable.
The Activate button selection set "in service" the MS-SPRing protection mechanism on the selected schema
configuration.
To change from Active to Enable click on the Deactivate button. This command starts the request to
deactivate the MS-SPRing protection mechanism
When the selected protection schema is Enable the Delete button starts the request to remove it. The delete
action is started after confirming the window message.

Figure 294.

Confirmation message

During the activation procedure on different ADMs some of these can be Activate status, others in Inactivate
status. The statuses, the protocol request and the protocol protection errors are described in next chapters
describing the "MS-SPRing Protection Status and Commands".
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

327/396

19.5 MS-SPRING Protection Status and Commands for 2 fiber terrestrial application
19.5.1 2F MS-SPRing protection commands
If a protection schema is Active it is possible to select one of the above commands.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Clicking on the Prot. Commands button in the MS-SPRing -> Main Dialog for MS-SPRing management
Figure below is opened.

Figure 295.

Protection states and commands "Idle" status (2F)

The working/protection span state boxes are not available (grey) for the 2Fibwer MS-SPRing architecture.
In the MSPRing 2 Fiber configuration, the 1-8 working channels are inserted into the 9-16 protection
channels in the opposite side of the failure event as shown in figure below.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

328/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 296.

Ring Protection (2F)

19.5.2 External commands (2F)


The external protection commands are: Lockout, Force, Manual, Exercise (not operative in current release).
Manual. WTR.
The lockout commands disable the MS-SPRing management.
The lockout section present six lockout commands, four operative. Each lockout command is applicable on
different points where the lockout actions has to be performed and any "Lockout" command is associated to
a "Release" command to come back to the previous status.
Term "Span" identifies the section interested by the command; it doesn't assume the Span meaning of the
four-fiber protection.

Figure 297.

ED

03

Lockout commands (2F)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

329/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 298.

Protection and working channels where the lockout command can be activated (2F)

The protection events can be equipment/signal failure, signal degrade or external command or a
combination of them.
The "Events" will be served if some actions (B/S=bridges and switches) are executed and the network has
been updated.
The "Events" will be signaled if the K1/K2 protocol communicates to the network nodes what has happened,
without execute actions.
A single ring failure is completely restored but not two ring failures. When are present multiple ring failures
the automatic B/S protection will try to maintain on all the possible connections.
The K1/K2 communication protocol MS-SPRing is generated from the two nodes adjacent to "Event" via the
protection communication channels. A node is defined tail-end when it firstly receives the "Event", the
second node is defined head-end when it receives back the protocol answer. Figure below shows the
association of tail end / tail end or head-end / tail end.
Some network protection mechanisms are accepted or rejected depending on the type (tail/head) (lockout
command.)

Figure 299.

Tail-end / Head-end association

If the node is tail end, the lockout working ring/span commands disable the protection MS-SPRing
mechanisms, while if the node is head-end, it serves the request node protection. (Protection not disable).
With the lockout protection span command and a ring failure, the ring protection is served if this ring failure
occurred the same section; the ring protection is disable if this ring failure has occurred in another ring
section. On the contrary, with the lockout working ring command failure and a ring failure along a different
section, the ring protection is served (protection non disable)

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

330/396

Figure 300.

ED

03
Tail-end / head-end protection with a lockout working and a one direction failure (2F)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

331/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 301.

Ring protection with a lockout and a ring failure (2F)

Figure below shows a ring with three nodes and the actions performed by the lockout commands. This
command disables the acknowledgment of the signal failure/degrade on the aggregate ports.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

332/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 302.

Lockout command and non-served failures (2F)

The Force command executes a forced protection. The Force Ring command substitutes the working
channels (AU4 1 to 8) with the opposite direction protection channels (AU4 9 to 16) between two adjacent
nodes.
The Force Span command is not operative in " fiber MS-SPring.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

333/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 303.

Figure 304.

Forced and Manual Commands (2F)

Manual and Force Span/Ring command (2F)

The Manual command is similar to Force command but it is at a lower priority level with respect to automatic
MS-SPRing. The general priority scale that can be applied to solve antithetical situations starting from the
lowest priority level is: manual ring - automatic working ring force ring - lockout working ring - lockout
protection span.
When a force ring command is applied a next working failure is not able to modify the forced configuration
applied. That is because force ring command has a higher priority respect to the "Automatic" working
protection. In this condition the ring can be split according the location of command and event. Vice versa
the "Manual" protection is exceeded by the "Automatic" protection. Figure below visualizes the ring
protection with a Force/Manual command and a signal failure. FS-R is for "Force Switching Request", SF-R
is for "Signal Failure Request".

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

334/396

Figure 305.

ED

03

Ring Protection with Force and Manual commands (2F)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

335/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 306.

Automatic protection Bridge/Switch (2F)

Each command starts when the proper button is selected. A dialog box has to be confirmed before the
command is performed.
From each command exists its own Release button to cancel the previously selected command and come
back to normal MS-SPRing protection.

Figure 307.

Example of confirmation dialog box

Clicking on the WTR command next figure opens. If the WTR box, in the Local Condition field of Figure
(Protection states and commands "Idle" status (2F)), becomes red a waiting time has been activated after
repairing the ring failure. The waiting time, set in the configuration menu, can be cleared selecting the Clear
WTR Ring command. A confirmation dialog box opens and, if the operator clicks OK, the WTR box turns off
and the protection status window is updated.

Figure 308.

Clear WTR command (2F)

19.5.3 2F MS-SPRing dual protection commands


In general dual contemporary "Events" can be:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

336/396

Two external commands


An external command and a ring/span failure
Two contemporary ring/span failures

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Dual "Events" can appear on the same side W/W (West/West) or E/E (East/East)(SS= same side) or on the
opposite side W/E or E/W (OS= opposite site) of the ring network. In the SS or OS the "Events" can appear
on the same node (SN) or on the different nodes (DN), the different node can be an adjacent node (AN) or a
remote node (RN). Figure below depicts a clockwise ring network. The network propagation K1-K2 protocol
signals are according to the following legend:
C

= served the column element

= served the row element

= served both row and column elements

Cs

= signaled (no served) the column element

Rs

= signaled (not served) the row element

Bs

= signaled (not served) both row and column elements

When a command (Manual switch, Force switch) is neither served nor signaled that is erased
(it is not pending at the node)

Figure 309.

Ring network reference scheme (2F)

Figure up visualizes the ring reference scheme: the adjacent node (AN) is the node connected to the
reference point.
The automatic protection for dual ring failure is below. Consider the network reference scheme with a tail end
/ head-end alarm propagation. In this figure are depicted the node switches for any reported double events.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

337/396

Figure 310.

ED

03

Examples of Double ring failure

SC.3: NE MANAGEMENT

3AL 98253 ADAA

338/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 311.

Automatic protection (tail/head) for double ring failure visualization

Schemas are applied to describe dual generic "Events" where both ring failures and external commands are
considered.
The first row at the top of the protection table shows the "Events" at the reference pint. For each of them the
associated "Events" is listed on the first column at the left of the table.
Two manual ring commands can be only signaled: Bs (Manual SS-SN and OS-AN commands give the same
ring protection switching and then both can be served).
Two Lockout commands are both always served: B
Force command has priority with respect to the Manual one.
Automatic protection has priority with respect to the Manual command.
Force Ring and Automatic Protection (or two Force ring commands) are always served if they are not applied
on the SS-SN. In this last case has to be considered the priority level. The behavior is that seen for two
automatic protection switching.
Lockout working SS.SN has priority with respect to Manual or Automatic protection and Force commands. In
the other cases. both commands are served (B).
Lockout protection SS.SN/OS-AN and Manual or Automatic or Force command are both served because the
switching SS.SN/OS.AN channels are not managed by the lockout protection: B.
Lockout protection SS-AN/OS-SN overrides the Manual or Automatic or Force command because the
lockout protection controls the switching channels of the same Node.
Lockout protection SS-RN/OS-RN and manual or automatic or force command. The lockout protection
prevents the working 1-8 channels from being inserted into protecting 9-16 ones. The lockout protection is
served, because it has a higher priority, the ring protection will be only signaled (pending).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

339/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 312.

Tail / head dual "Events" Protection table (2F)

19.5.4 2F Protection Status Visualization


The protection statuses ring networks are:
-

1 - Lockout Switching

2 - Forced Switching

3 - Automatic Switching (MS-SPRing protection for equipment/signal failure).

4 - Manual Switching

5 - Idle (regular operation without MS-SPRing protection)

These protection states are represented with the following color state boxes:
-

Green: Active State, No Request condition

Red: Inactive State and any external or protection executed command (that has been served).

Yellow: ordered but not executed command (that has only been signaled = pending status)

Grey: not available state box.

Automatic switching and external commands are revertive: then when the "Events" have been cleared, the
MS-SPRing configuration comes back to its status.
The state boxes visualize the "Node Condition Request" as a consequence of the equipment/signal failure or
the external commands detected on the corresponding side ("Event"). The state boxes don't describe the
protection actions provided on the NEs.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

340/396

The served "Events" (B/S=bridges and switches are executed and the network has been updated) are
completed B/S actions visualized as red box indications.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The signaled "Events" (the k1/k2 protocol communicates to the network nodes what has happened) are
pending B/S visualized as yellow box indications.
Figure below shows the protection status with a served East manual ring command. Any protection status
window is divided in different status fields: Schema description and status, Local Conditions, Node
Conditions and Protocol Exceptions. The first one describes the network configuration and application type
and its status, the second gives the local external commands indications, the third the "Events" result on the
nodes and the fourth one checks the k1/k2 ring protocol. The window is divided into three parts: West,
Middle and East. On the West there are all the box indications corresponding to the West protections and
commands. In the middle "WTR-Ring" refers to West and East sides, "No Request" corresponding to "Idle
Status", and "Intermediate Node" denotes that the protections and commands don't concern the node
involved. The Manual Ring command visualizes "Manual Ring" on the local node and "Request Node Ring"
in the both "Local Conditions adjacent East ADM1-West ADM2 nodes, while the 3 and 4 nodes are
"Intermediate Node". The red color means that the command has been served. A regular protocol
"Exceptions" is represented with white boxes; a protocol alarm is signaled with red boxes. The "Prot.
Unavailable" indications are activated when a lockout protection command is applied in a network node.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

341/396

Figure 313.

ED

03

Manual command applied at the "Reference Point" ring network

SC.3: NE MANAGEMENT

3AL 98253 ADAA

342/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure below reports the "Protection Status" for external "Force and Manual" commands in a 3 -node ring (A,
B, C). Figure below shows the lockout statuses and Figure below the automatic protection statuses.

Figure 314.

ED

03

Visualization of the Forced / Manual protection Statuses (2F)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

343/396

Figure 315.

ED

03
Visualization of the Lockout command Statuses (2F)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

344/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 316.

Visualization of Automatic Protection Statuses (2F)

The WTR status is visualized on the side where the link has been repaired. The considered network failures
are related to a tail-end/head-end node connection. The "WTR Clear" command can be executed by the user
without waiting the WTR setting time.
19.5.4.1 Double ring failure
The double ring failure visualization Figures (Example of Double ring failure) are here following reported.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

345/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 317.

Protection status with double ring failure (reference point -SS-AN)

Figure up reports the protection status with double ring failure (reference point-SS-AN). The node 2 isolated,
the nodes 2-3 in switching and the node 4 intermediate. The box color is white unless otherwise specified:
"Active: green
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

346/396

"Request Node Ring" West ADM3-East ADM1: red (served)


"Request Node Ring" West ADM2-East ADM2: yellow (pending)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM4: red

Figure 318.

ED

03

Protection status with double ring failure (reference point-SS-RN)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

347/396

Figure up reports the protection status with double ring failure (reference point-SS-RN). The nodes 1,2,3,4
are being switched for signal failure alarm and both the two signal failures are served. The box color is white
unless otherwise specified:
"Active: green
"Request Node Ring" East ADM3-Eas ADM1: red (switching for SF)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Request Node Ring" East ADM4-East ADM2: red (switching of the opposite nodes)

Figure 319.
ED

03

Protection status with double ring failure (reference point-OS-AN)


SC.3: NE MANAGEMENT
3AL 98253 ADAA

348/396

Figure up reports the protection status with double ring failure (reference point-OS-AN). The nodes 1,2 are
being switched for signal failure alarm and both signal failures are served: B. The box color is white unless
otherwise specified:
"Active: green
"Request Node Ring" West ADM2-East ADM1: red (switching for SF)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM3-ADM4: red

Figure 320.

ED

03

Protection status with double ring failure (reference point-OS-AN) recovering to "idle"

SC.3: NE MANAGEMENT
3AL 98253 ADAA

349/396

Figure up reports the previous protection status with double ring failure (reference point-OS-AN) while the
ring protection comes back to its "idle" status. The "WTR (Wait To Restore) Ring" on ADM1 node becomes
red to signal that the SF disappears at the "reference point". The box color is white unless otherwise
specified:
"Active: green
"WTR Ring: red (to signal the SF recovering)
"Request Node Ring" West ADM2-East ADM1: red

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM3-ADM4: red

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

350/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

19.5.4.2 Double external command or an external command and a ring failure

Figure 321.

Double manual ring command (reference point-SS-AN)

Figure up report the protection status with double manual command (reference point-SS-AN). Both the
commands can be only pending. The "Request ring" to 1,2,3 nodes becomes pending while the 4 node is
"Intermediate node". The box color is white unless otherwise specified.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

351/396

"Active": green
"Request Node Ring" East ADM1-West ADM2: yellow (pending) for Manual Ring East ADM1
"Request Node Ring" East ADM2-West ADM3: yellow (pending) for Manual Ring East ADM2
"Request Node Ring" West ADM1-East ADM3: yellow (pending) for switching of the opposite nodes

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM4: red

Figure 322.

ED

03

Double manual ring command (reference point-OS-AN)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

352/396

Figure up reports the protection status with double manual command (reference point-OS-AN). Both the
commands can be served. The "Request Manual ring" to ADM1 (East) and to ADM2 opposite side (West)
collapses in the same manual command. Both the manual commands are served. The box color is white
unless otherwise specified:
"Active: green
"Request Node Ring" East ADM1-West ADM2: red (served)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM3, ADM4: red

Figure 323.

ED

03

Manual ring and Lockout Protection (reference point-SS-SN)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

353/396

Figure up reports the protection status with a manual command and a lockout protection (reference pointSS-SN). Both the manual and the lockout commands are visualized to the same ADM1 node (East). Both the
commands are served because the bridge/switch points are different. The box color is white unless
otherwise specified:
"Active: green
"Request Node Ring" East ADM1 - West ADM2: red (served)
"Intermediate Node" ADM3, ADM4: red
"Manual Ring and Lockout Prot." commands East ADM1: red

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Prot. Unavailable" East ADM1: red.


N.B. The "Prot. Unavailable" is not propagated on West ADM2 node because on West ADM2 the
protection switching has been executed.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

354/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 324.

Manual ring and Lockout Protection (reference point-SS-RN)

Figure up reports the protection status with a manual command and a lockout protection (reference pointSS-RN). The manual command is pending while the lockout command is served. The box color is white
unless otherwise specified:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

355/396

"Active: green
"Manual Ring" commands East ADM1: yellow
Request Node Ring" East ADM1 - West ADM2: yellow (pending)
"Request Node Ring" West ADM1 - East ADM2: yellow (pending) for switching of the opposite nodes
"Lockout Prot." command: East ADM3: red

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Prot. Unavailable" East ADM3 and West ADM4: red (served)

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

356/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 325.

Automatic working ring and Manual Ring (reference point-OS-AN)

Figure up reports the protection status with a ring failure and a manual ring command (reference point-OSAN). The automatic protection has a higher priority with respect to the manual command and then it has
been served. The box color is white unless otherwise specified:
"Active: green
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

357/396

"Request Node Ring" East ADM1-West ADM2: red (served)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM3-ADM4: red

Figure 326.

Automatic working ring and Force Ring (reference point-SS-AN)

Figure up reports the protection status with a ring failure and a force ring command (reference point-SS-AN)
The ADM2 is isolated and the force command is pending. The box color is white unless otherwise specified:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

358/396

"Active: green
"Request Node Ring" East ADM1: red (served) the West ADM1 switching is applied for SF
"Request Node Ring" West ADM3: red (served) the East ADM3 switching is applied for the force command
"Request Node Ring" West ADM2, East ADM2: yellow (pending) the ADM2 is isolated

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM4: red

Figure 327.

ED

03

Automatic working ring and Lockout working Ring (reference point-SS-SN)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

359/396

Figure up reports the protection status with a ring failure and a lockout working command (reference pointSS-SN). The lockout command has a higher with respect to the automatic protection switching and then only
the lockout command has been served. The box color is white unless otherwise specified:
"Active: green
"Lockout Ring" commands East ADM1: red
"Request Node Ring" East ADM1 - West ADM2: red (served)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM3 - ADM4: red

Figure 328.

ED

03

Automatic working ring and Lockout Protection (reference point-OS-RN)

SC.3: NE MANAGEMENT
3AL 98253 ADAA

360/396

The lockout protection has a higher priority with respect to the automatic ring protection. The box color is
white unless otherwise specified:
"Active": green
"Lockout Prot." commands West ADM3: red
"Prot. Unavailable" West ADM3 - East ADM2: red (lockout protections served)
"Request Node Ring" East ADM1 - West ADM2: yellow (automatic protection is pending)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

"Intermediate Node" ADM4: red

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

361/396

20 ISA/IP/ETH CONFIGURATION
20.1 Introduction
This Chapter describes the operations necessary for the ATM/PR_EA/Ethernet boards creation in the
Equipment view and the ATM/PR_EA/Ethernet TTPs creation; as a matter of fact ATM/PR_EA/Ethernet
boards does not crate TTPs when they are configured.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The ATM/Ethernet/PR_EA board creation is performed when CT users sets an ATM/PR_EA/Ethernet board
and then configure the IP Address.
For the TTPs creation refer to paragraph 20.2 where all the operation are explained.
For the ATM/PR_EA/Ethernet traffic configuration (for example creation of Hard/Soft cross connection, PNNI
configuration etc.) refers to the relevant OPERATORS HANDBOOK (ATM or PR_EA) where Specific
Terminal application is explained in details.
The operational sequence to follow to manage ATM/PR_EA/Ethernet crossconnection is:
a) ATM/PR_EA/Ethernet board declaration (Equipment Set)
b) ATM/PR_EA/Ethernet IP Address Configuration (Called ISA board IP Address)
c) ATM/PR_EA/Ethernet board TTPs creation (VC4XV, VC12XV, VC3XV, VC44c TTP, VC4 TTP, VC3 TTP,
VC12 TTP, s31 TTP, E1 TTP)
d) TTPs crossconnection.
e) ATM/PR_EA/Ethernet traffic configuration with Specific Terminal application

20.2 ATM/PR_EA/Ethernet board TTPs creation


In this paragraph will be explained how to create, delete and modify ATM/IP/ETH TTPs.
20.2.1 ATM boards
On the ATM 4X4 board can be configured up to 16 TPs (VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP, E1TTP)
with a maximum throughput of 622 Mbit/s.
On the ATM 8X8 board can be configured up to 32 TPs (VC44c TTP, VC4 TTP, VC3 TTP, VC12 TTP, s31
TTP, E1 TTP) with a maximum throughput of 1.2 Gbit/s.
Select ISA/IP/ETH Configuration option from the Configuration menu to open the ISA/PR_EA/Ethernet
ports Configuration.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

362/396

Figure 329.

ED

03
ATM 4X4 MATRIX (initial empty fields)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

363/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 330.

ATM 4X4 MATRIX (with defined TPs)

The ATM/IP/Ethernet ports Configuration window is filled with notebook pages (initially blank), each page is
an ATM, Ethernet or PR_EA board with relevant ports;
The user can create a new port, delete an existing one and change port associations (that means
modify the STM1 number and STM1 Time Slot on ATM/IP/Ethernet ports already created) via the three
buttons contained in the notebook page.
When the users want to create a new ATM port he can select an empty row, then in the Selected Item
sections, he can fill the field Signal choosing among the available options and push the Create button.
The STM1 Number and the STM1 Time Slot are automatically assigned.
If the users want to change the port attribute association he can select a filled row, then in the Selected
Item section he can change the fields STM1 number and STM1 Time Slot and than push the Time Slot
Sw. button.
To delete a port the user can select a row and push Delete button.
To close the dialog box click on the Close push button.
It is possible to see the ATM Ports created as above explained by selecting the relevant row in the
ATM/IP/Ethernet configuration window and then click on the Navigate button.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

364/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 331.

Navigate to ATM port view (example)

20.2.2 PR_EA boards


On the PR_EA boards can be configured the following TPs:
PREA4ETH: up to 59 TPs (SDH VC4, SDH VC3, SDH VC12) with a maximum throughput of 622 Mbit/s.
PREA1GBE: up to 62 TPs (SDH VC4, SDH VC3, SDH VC12) with a maximum throughput of 622 Mbit/s.
Select ISA/IP/ETH Configuration option from the Configuration menu to open the
ATM/PR_EA/Ethernet ports Configuration.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

365/396

Figure 332.

ED

03
PR_EA MATRIX (initial empty fields)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

366/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 333.

PR_EA MATRIX (with defined TPs)

The ATM/IP/Ethernet ports Configuration window is filled with notebook pages (initially blank), each page is
an ATM, Ethernet or PR_EA board with relevant ports;
The user can create a new port, delete an existing one and change port associations (that means
modify the STM1 number and STM1 Time Slot on ATM/IP/Ethernet ports already created) via the three
buttons contained in the notebook page.
When the users want to create a new PR_EA port he can select an empty row, then in the Selected Item
sections, he can fill the field Signal choosing among the available options and push the Create button.
The STM1 Number and the STM1 Time Slot are automatically assigned.
If the users want to change the port attribute association he can select a filled row, then in the Selected
Item section he can change the fields STM1 number and STM1 Time Slot and than push the Time Slot
Sw. button.
To delete a port the user can select a row and push Delete button.

To close the dialog box click on the Close push button.


It is possible to see the PR_EA Ports created as above explained by selecting the relevant row in the
ATM/IP/Ethernet configuration window and then click on the Navigate button.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

367/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 334.

MPLS port view example

20.2.3 10/100 Mbit/s fast ETHERNET board


On the FAST ETHERNET boards can be configured up to 11 TPs (VC4 TTP, VC3 TTP, VC12 TTP, C12XV
and VC3XV) on the port card (ETHMB) and up 14 TPs (VC4 TTP, VC3 TTP, VC12 TTP, VC12XV and
VC3XV) on the relevant access card (ETHATX).
Select ISA/IP/ETH Configuration option from the Configuration menu to open the ATM/PR_EA/Ethernet
ports Configuration.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

368/396

Figure 335.

ED

03
ETHMB (initial empty fieds)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

369/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 336.

ETHMB (with defined TPs)

The ATM/IP/Ethernet ports Configuration window is filled with notebook pages (initially blank), each page is
an ATM, Ethernet or PR_EA board with relevant ports;
The user can create a new port, delete an existing one and change port associations (that means
modify the STM1 number and STM1 Time Slot on ATM/IP/Ethernet ports already created) via the three
buttons contained in the notebook page.
When the user want to create a new TPs he can select an empty row, then in the Selected Item sections,
he can fill the field Signal choosing among the available options and push the Create button.
Note: in case of concatenated VC TP creation (example VC12XV or VC3XV), before to push on Create
button it is also necessary to choose the Concatenation Level value; after creation command new fields and
a new button appear.
The STM1 Number and the STM1 Time Slot are automatically assigned.
If the user want to change the port attribute association he can select a filled row, then in the Selected Item
section he can change the fields STM1 number and STM1 Time Slot and than push the Time Slot Sw.
button.
The Ctrl Path Act. button allows to change the state of the concatenated virtual VCs (example VC12XV or
VC3XV) that could be Idle or active.; Click on Ctrl Path Act. button a new window will be opened.
To delete a port the user can select a row and push Delete button.
To close the dialog box click on the Close push button.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

370/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 337.

Control Path activation window (example)

It is possible to see the VCs created on the ETHERNET board as above explained by selecting the relevant
row in the ATM/IP/Ethernet configuration window and then click on the Navigate button.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

371/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 338.

ETHERNET port view example

20.2.4 Gigabit/s ETHERNET board


Three architectures are possible to provide Gigabit Ethernet ports:
[1] 10/100Mbit/s Ethernet board (ETHMB)+GBIT Access (GETHAG).
With this architecture can be configured up to 2 TPs (VC4XV TTP Type concatenation level=1) on
the GETHAG access card and up to 11 TPs (VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP, E1 TTP Type) on
the ETHMB main board taking into account that the maximum throughput must not exceed 622 Mbit/s.
[2] GIGABIT board (GETHMB) standalone.
With this architecture can be configured up to 4 TPs (VC4XV Type) on each board taking into account that
the maximum throughput must not exceed 622 Mbit/s (for example it is possible to configure 1 port VC4XV
with a max. concatenation level equal to 4 or as alternative 4 ports VC4XV with concatenation level equal to
1).
The same rules above described are applicable to 1662SMC when the GIGABIT board (GETHMB) is
equipped in normal slot (i.e. slot with a throughput of 622 Mbit/s).
If the GIGABIT board (GETHMB) is equipped in one of these slots it is possible to reach a max
concatenation level equal to 7 per port. Of course this means that there is only one VC4XV with
concatenation level =1 available for another port and no resources for the last two ports present on the board.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

372/396

For more details read the Gigabit Ethernet description reported in the Technical Handbook.
[3] GIGABIT board (GETHMB) + GBIT Access (GETHAG).
With this architecture can be configured up to 4 TPs (VC4XV Type) on the GETHAG access card and up to
4 TPs (VC4XV TTP Type) on the GETHMB main board taking into account that the maximum throughput
for the couple must not exceed 1.2 Gbit/s.; the concatenation level per port can be from 1 to 7.
The Gigabit Ethernet TPs creation follows the same rules described for the 10/100Mbit/s Ethernet Board.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

20.2.4.1 Configuration of the auto-negotiation protocol on Gigabit Ethernet interface


In order to inter-working both with Gigabit Ethernet interfaces supporting the auto-negotiation protocol and
with Gigabit Ethernet interfaces not supporting it, the configuration of the auto-negotiation protocol has to be
managed also for the Gigabit Ethernet board, since R2.2.
The conditional package auto-Negotiation Package has to be instantiated by GMAU TTP Bid created at
Gigabit Ethernet SFP configuration of the board Gigabit Ethernet rate adaptive (GETH-MB); it has to be
confirmed if the auto-Negotiation Package has not to be instatiated also by GMAU TTP Bid of SFP of Gigabit
Ethernet access card (GETH-AG) in case of Gigabit Ethernet Stop Gap solution, since it doesnt support the
protocol. The default value for auto-negotiation Status is disabled, for backward compatibility reasons, since
in the previous releases the protocol was not supported on Gigabit Ethernet interfaces.
Because of the Gigabit Ethernet application in OMSN doesnt negotiate nothing: it works only at Gigabit rate
full duplex with Asimmetric pause mode, the only mainingfull attribute to be managed is auto-negotiation
Configuration, which enables or disables the protocol; the attributes auto Negotiation Configuration Par, auto
Negotiation Current Status, auto Negotiation Remote Signalling are auto Negotiation Remote Status have
not to be managed and in case of manager request, the NE replies service Not Supported. The action auto
Neg Restart has been requested in order to trigger the activation of the protocol when it has been enabled.
20.2.5 ES1-8FE boards
The Alcatel Reference ISA-ES NE can integrate:

Local Ethernet Interface


__ 8 local Ethernet 10/100 BaseT interface;

Remote Ethernet interface


__ Remote Ethernet 10/100 interface mapped into a single VC12, VC3, VC4, VC12 nv[n=1..63],
VC3-nv [n=1.3];
__ Remote Gigabit Ethernet interface mapped into a SDH VC4.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

373/396

Figure 339.

ED

03
ES1-8FE MATRIX (initial empty fields)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

374/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 340.

ED

03
ES1-8FE MATRIX (with defined TPs)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

375/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 341.

Navigate to ETH port view (example)

20.2.6 ES4-8FE boards


ES4-8FE board is supported from R.2.2 and it supports up to 8 100MB optical interfaces
ES4-8FE doesnt foresee any access cards.
ES4-8FE supports up to 16 trunks between the SDH mapper and the L2 switch, in detail we can use up to 12
vc3 Groups (vc3Xvirtual), or up to 16 vc12 Groups (vc12Xvirtual) for a total maximum backplane capacity of
622 Mbit/s.
Furthermore ES4-8FE supports up to 4 vc4 terminations (vc4TTP), or up to 12 vc3 terminations (vc3TTP), or
up to 252 vc12 terminations (vc12TTP), for a total maximum backplane capacity of 622 Mbit/s.
Each vc3 groups can contains up to 2 vc3 (vc3Virtual) and each vc12 Group can contain up to 50 vc12
(vc12Virtual).
NOTE: Up to 2 vc3Virtual per vc3Xvirtual are considered enough for supporting 100Mbit, according to OMSN
DR1 meeting of December 2003.
LCAS protocol is supported on these VCs.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

376/396

Figure 342.

ED

03
ES4-8FE MATRIX (initial empty fields)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

377/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 343.

ED

03
ES4-8FE MATRIX (with defined TPs)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

378/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 344.

Navigate to ETH port view (example)

20.2.7 ISA-ES16 board


ISA Ethernet Switch at STM-16 (ISA-ES16), the detailed management description is present on [41], it has to
be managed since Rel. 2.3.
ISA-ES16 can integrate 14 local Ethernet 10/100 Base T via ISA ETH access board. And it can integrated 4
local GE 1000Base SX/LS(SFP module) via ISA GbE access board.
LCAS protocol is supported on these vc.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

379/396

ED

03
Figure 345.
ISA-ES16 MATRIX (initial empty fields)

Figure 346.

ISA-ES16 MATRIX (with defined TPs)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

380/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 347.

ED

03
Navigate to ETH port view (example)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

381/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

21 Software Management
21.1 Generalities and descriptions

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Craft Terminal provides a set of functions, which allow software packages manipulation within NEs. The
downloading operation consists in the establishment of session between the NE and a software server for
the purpose of file transfer.
Actions can then be performed on the NE software version as update and activation operation, or roll back
to the previous software version operation. In this way the NE can follow the product evolution with "in
service" equipment.
The same function is used during maintenance phase, to update spare boards for substitution after
troubleshooting.
The operations that can be undertaken in this section are:

Display Software Download Information,

Initiate / Abort Software Package Download,

Manage Software Packages within NEs, activating the downloaded Software Package or coming
back to the previous condition.

A backup/restore can be also done on the MIB of the NE. Indeed the MIB can be saved to or restored from
the mass storage of the Craft Terminal.
The software download general principle is represented in the following figure.

Figure 348.

Software Download general principle

21.1.1 Naming Conventions


The naming conventions used for Download Management are the following:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

382/396

Software Package: Software Package stands for a piece of software, which can be executed by an
NE of a particular type. It consists in one or more Software Units and a Descriptor File. A software
package is identified by its name, release, version and edition.
On the NE (i.e. once downloaded) a software package can be:

- The active version: the software package currently running on the NE

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- A standby version: a software package, which is neither the active version nor the boot version

Software Unit: A Software Unit is a part of a software package, which can be either executable
code, or a data segment of a particular board within an NE. A software unit is also identified by its
name, release, version and edition.

Descriptor File: A Descriptor File contains information about the software package it belongs to and
lists the composing software units. Each software package must have a descriptor file otherwise it
would not be possible to interpret the content of the package.

Software Management Function: The Software management function offers information about all
current software packages present in an NE. Indicators enable software management (running
package, activated package, etc...).

The following software version states are available:

Commit (active) version: the software version currently running on the NE.

Standby version: is a software version which has been downloaded on the NE but which is not in
the active state.

Two main functions are involved in the software downloading:


- Software Download Manager function
- Software Download Server function
The Software Download Manager function takes the downloading and management requests of the operator
and sends them to the NE. Thus, this function enables a download process to be initiated and monitored by
the operator. It manages the NE software releases and initiates software download operations.
The Software Download Server is only responsible for fulfilling the requests received from NEs and
performing software package file transfer operations to the NE.

21.2 Software download operative sequence


Two main different operative condition are defined for this Equipment:
First installation of a 1662SMC
The NE is received without the relevant software install. The software download must be done
As described in the SIBDL section of this Handbook.
Updating a 1662SMC with already installed software.
Follow the operative indications.
21.2.1 Software Download upgrade
N.B. In order to migrate from Release 1.1A to a Higher Release, the download procedure requires
Two steps. The first is from 1.1A to 1.1X (intermediate package) and the second is from 1.1X
To the Higher Release (e.g. 1.1B1).
In order to update the following procedure is to be done as explained in the next steps:
a) Install the CD ROM with the NE Software Package on the PC.
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

383/396

b) Open a session on Craft Terminal application (start-up of the application, start supervision and NE login)
c) Check the present status of the software on a selected NE.
Download should not be performed in presence of unstable alarms
d) Open the Download menu.
e) Select the new software package in the server and triggers the download process, A message will indicate
the completed download.
f) Activate the package as presented at para.20.5 on page 333.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

g) Check that the activated package is in the Commit status.


h) If problems are found with the new activated package, activate the previous software package
(Revert--back operation) to come back to the previous condition and then try to repeat the procedure.
21.2.2 NE Software package installation procedure
The following procedure allows the NE software package installation. According to the customer
Requirement two types of installation are possible:
[1] If only SDH software package installation is required follow the instruction from point a) to point e) and
than download the software package SDH (example 662SMC 2.1B.09) from the EMLUSM (refer to
paragraph 20.4 for details).
[2] If SDH+Specific Software package installation is required follow the instruction from point a ) to point o ).
In the example that follows will be described the ATM specific software installation; following the same rule
will be possible to install also the IP specific software.
21.2.3 Procedure
a) Install from CD ROM the NE Software Package on the Personal Computer, as explained in the
1320CT Basic Operator Handbook.
b) Run the 1320CT V.x platform
c) From Network Element Synthesis (NES) choose the Software Administration option of the Supervision -> File Administration menu.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

384/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 349.

Software Administration menu

After the selection Figure below. Will be opened.

Figure 350.

Software Package Administration view

d) Select the <SDH/WDM> tag


e) Press the <INSTALL> button to install the relevant software package
In the window that opens select the directory where the NE software package file has been installed
(Typically is Alcatel/usm/ect/swdw/<equipment name>/<version>/<descriptor file>) and execute.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

385/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 351.

SDH software package installation

f) Insert the ATM CD ROM in the computer


g) Select the <SERV. SPEC.> tag
h) Press the <INSTALL> button to install the ATM software package present on the ATM CD ROM In the
window that opens select the directory where the ATM software package file has been installed (typically is
/ect/swdw/<atm>/<version>/<descriptor file>) and execute.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

386/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 352.

ATM software package installation (example)

i) Select the <SDH/WDM> tag


j) Select the SDH software package base onto which ATM software package has to be merged
k) Press <Create Enhanced> to launch the software merging process and create the SDH+ATM
Software package The New Software package will be created.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

387/396

Figure 353.

ED

03
OMSN enhanced software package creation (part A)

SC.3: NE MANAGEMENT

3AL 98253 ADAA

388/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 354.

OMSN enhanced software package creation (part B)

The originated Enhanced software package has a new label as follows:


OMSN name = is the SDH name + E letter
OMSN version = is the SDH version
Example: Starting from SDH SWP 662SMC ver. 3.xy.wz will be created the OMSN SWP
662SMCE ver. 3.xy.wz
l) Select the <OMSN> tag.
m) Select the previously created software package (example 662SMCE 3.1.08)
n) Select the ATM software package (in the right view) (example ATM 1.01.07)
o) Press the <ADD> button

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

389/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 355.

Enhanced software package (SDH + ATM)

It is now possible to download the enhanced software package (SDH + ATM) from the EML-USM
(Refer to paragraph 20.4 for details).

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

390/396

21.3 Software Download Manager menu

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All the software download operations are carried out from the software download manager.

Figure 356.

Equipment view

To display the software download manager menu from the main view, select the NE on which you want to
perform download operations, then select the Download pull down menu. The following menu is displayed:

Figure 357.

ED

03

Download menu

SC.3: NE MANAGEMENT
3AL 98253 ADAA

391/396

21.4 Init download


You can request the NE to start / abort a software download operation. After selecting the desired NE you
must choose an available software package and then start the download process. All these operations can
be performed from the SW downloading dialogue box.
Select the Init download option from the Download cascading menu.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The Software download initiate dialogue box is opened.

Figure 358.

SW Downloading dialogue box example

The following fields are available to search a specific package:

Server filter: to enter the server name selected,

Package filter: to enter the package name selected.

To use the filter and display the selection, push on Apply filter(s) button. The SW packages existing on the
Craft Terminal are displayed.
In the next field the list of the packages is displayed:

Server: name of the server,

Package: name of the package,

Version: version number of package.

Click on Forced push button to set the forced download attribute: then all software units of the Descriptor file
have to be downloaded. Otherwise only the units with different software version will be loaded.
If you want stop the download, click on the Cancel push button of the Software download initiate dialogue
box to close it.
Click on the OK push button to start the download. From the confirmation dialogue box that opens, you can
confirm or cancel the download. If you confirm the operation, the SW Downloading dialogue box then
disappears and the Software download in Progress dialogue box is displayed from which you can if
necessary abort the software download.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

392/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

You can monitor the download progress by means of the Software in Progress dialogue box, which also
enables you to possibly abort the current download.

Figure 359.

Software download in progress (example)

The Software download in Progress dialogue box displays the name and type of the NE and the SW
package name, the total of bytes, the current percentage and the current file, which is being downloaded.
Click on the Abort push button to abort the complete download transaction. From the confirmation dialogue
box that opens you can confirm or cancel the abort.
Click on the Close push button to close the SWDL Work in Progress dialogue box at the end of the software
download.

21.5 SW package Activation and Units information


This item permits to activate the downloaded software package and to get information about the software
of the various units of the equipment.
The operator is able to get information about the software package of the NE at any moment, even if no
download operations have been performed previously.
For this, select the Units info option from the Download pull down menu.
The following dialogue box is opened.

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

393/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 360.

Software Package Information dialogue box (example)

The SW Information dialogue box displays the name and type of the NE, and the respective package name
and status of the committed and (if existing) the uncommitted software.
You can select one software package by clicking on the name.
The following fields are displayed:

Software package: name, release, version, edition of the package,

Service Specific Components: name, release, version, edition of the Service Specific Components
(example ATM, IP etc.)

Operational state: enabled or disabled,

Activation date: date and hour of the last activation

Vendor: the supplier of the product,

Current state\Action: commit or stand-by and with the option button; none/Force/Activate/Delete
Current state = standby means the package is not active on the NE
Current state = commit means the package is active on the NE
Action = (none) means no action to do

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

394/396

Action = activate serves to activate the selected SW package


Action = force (item not operative)
Select the Activate option of the "Current State\Action" field, to activate the Software package
The Sw units Det. button allows giving more information about a selected software package.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Clicking on it, the following window is displayed:

Figure 361.

Detail software package (example)

Clicking on [-] symbol behind each software package all details disappear.
When you click on Close the previous view is displayed
In when you click on the:

OK push button you close dialogue box,

Cancel push button you close the SW Information dialogue box,

Help push button you access to help on context.

21.6 Mib management


This function allows to make a backup and/or a restore of the Mib.. (MIB is a data base pertaining the
configuration of the equipment).
Select the Mib management option from the Download pull down menu. The following window is displayed:

ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

395/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 362.

NE MIB management

The following fields are displayed:

Available backups on local server: gives the list of the backups available on the Craft Terminal,

Backup name: to enter the new backup name.

Three push buttons allow choosing the action with click on:

Backup: performs the backup on the CT of the Mib present on the NE,

Restore: this function allows the managing system to restore the NE configuration database of the
managed system. Only one restore operation can be performed at the same time on a given NE.

Delete: this action allows deleting a backup of the NE database. The NE is not involved in this action.
The only effect is to delete the selected backup version stored in a specific directory of the FT server.

To activate an already restored MIB you click on Activate push button. Only at this point it becomes
operative on the NE.
To exit of the NE MIB management window, you click on Close push button.
To save or load the Mib to/from an external disk follow the indication of the "Basic 1320CT Operator's
Handbook" using the menu options of the Network Element Synthesis.

END OF DOCUMENT
ED

03

SC.3: NE MANAGEMENT
3AL 98253 ADAA

396/396

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alcatel 1662SMC Rel2.4 Operator Handbook

Alcatel 1662SMC Rel2.4


NE Maintenance

03

09/01/2006

Creation

ED

DATE

CHANGE NOTE

Distribution: Internal

Chen Yu
APPROVED BY

PREPARED BY

External

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

1/51

LIST OF FIGURES AND TABLES ....................................................................................................................4


1

INTRODUCTION .......................................................................................................................................6
1.1
1.1.1

Document scope...........................................................................................................................6

1.1.2

Target audience............................................................................................................................6

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.2

Scope6

Terminology6

1.2.1

Acronyms and abbreviations ........................................................................................................6

1.2.2

Glossary of terms..........................................................................................................................6

MAINTENANCE INTRODUCTION............................................................................................................7
2.1

Introduction 7

MAINTENANCE OF THE PC ....................................................................................................................8


3.1

Introduction 8

PROBLEM WITH CRAFT TERMINAL...................................................................................................9


4.1

Purpose of the procedure 9

CORRECTIVE MAINTENCE (TROUBLESHOOTING)...........................................................................10


5.1

Purpose of the procedure 10

5.2

Troubleshooting organization 10

5.3

On site Troubleshooting12

5.4

Troubleshooting by means of the Craft Terminal.14

5.4.1

Preliminary Concepts and Definitions.........................................................................................15

5.4.2

Alarms/states view Organization (subrack view) ........................................................................16

5.4.3

Alarm synthesis indication ..........................................................................................................17

5.4.4

Alarm Surveillance (AS)..............................................................................................................20

5.4.5

Port View alarms.........................................................................................................................27

5.4.6

Board view alarms and states.....................................................................................................31

5.4.7

Subrack and Rack view alarms ..................................................................................................33

5.4.8

Fans Subrack alarms view..........................................................................................................35

5.4.9

Equipment View alarms ..............................................................................................................36

5.4.10
6

External Points alarms (Housekeeping) .................................................................................37

UNIT REPLACEMENT WITH A SPARE.................................................................................................39


6.1

COMPACT ADM unit replacement39

6.2

ATM MATRIX 4X4 unit replacement 44

6.3

IP MATRIX unit replacement 46

7
ED

UPGRADING WITH NEW HARDWARE.................................................................................................47


03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

2/51

SYNTH substitution with SYNTHN 47

7.2

P4S1, S-41, L-41, L-42 substitution with P4S1N, S-41N, L-41N, L-42N 51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

7.1

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

3/51

LIST OF FIGURES AND TABLES

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

FIGURES
Figure 1.

General Flow-chart for on site troubleshooting...........................................................................13

Figure 2.

Power supply alarm ....................................................................................................................14

Figure 3.

Transmission network level structure .........................................................................................16

Figure 4.

Alarms/status view Organization (subrack view) ........................................................................17

Figure 5.

Alarm pull down menu ................................................................................................................20

Figure 6.

Alarm Surveillance......................................................................................................................21

Figure 7.

Example of SDH Port View alarms (with MSP schema).............................................................29

Figure 8.

Example of ATM Port View alarms .............................................................................................30

Figure 9.

Example of Ethernet Port View alarms.......................................................................................31

Figure 10.

Example of SDH Board View alarms and status ........................................................................32

Figure 11.

Example of PDH Board View alarms and status ........................................................................33

Figure 12.

Example of Subrack view alarms and status..............................................................................34

Figure 13.

Example of Rack view alarm and status.....................................................................................35

Figure 14.

Fans subrack alarms view ..........................................................................................................36

Figure 15.

Example of Equipment View alarms and status .........................................................................37

Figure 16.

Example of External Points alarms and status ...........................................................................38

Figure 17.

COMPACT ADM unit replacement (EPS protected) ..................................................................41

Figure 18.

COMPACT ADM unit replacement (EPS not protected) ............................................................42

Figure 19.

Consulting and/or setting the local NE time................................................................................43

Figure 20.

NE Time dialogue box ................................................................................................................44

Figure 21.

ATM MATRIX 4X4 unit replacement without EPS protection.....................................................45

Figure 22.

ATM MATRIX 4X4 unit replacement with EPS protection..........................................................46

Figure 23.

Upgrading with a new SYNTHN EPS not protected ...................................................................48

Figure 24.

Upgrading with a new SYNTHN EPS protected .........................................................................50

TABLES
Table 1.

Alarms colors and Severity association ..........................................................................................18

Table 2.

Alarm Synthesis indication ..............................................................................................................18

Table 3.

Domain Alarm Synthesis indication ................................................................................................19

Table 4.

Management States Control Panel. ................................................................................................19

Table 5.

Alarm Surveillance information general description........................................................................22

Table 6.

General aspect of alarms meaning and relevant maintenance actions..........................................22

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

4/51

Board Alarm ....................................................................................................................................24

Table 8.

Module Alarm ..................................................................................................................................26

ED

03

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Table 7.

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

5/51

INTRODUCTION

1.1
1.1.1

Scope
Document scope

The aim of this document is to help the operator understand, configure and manipulate Network Elements
(NEs) easily, using the Craft Terminal (CT). The different functionalities related to the equipment views, the
menu items and the different actions that can be undertaken from these views are described in detail.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.1.2

Target audience

This document is intended for the operators whose role is to manage the Network Elements.
The documents that should be read before starting this document are:
--- 1320CT Basic Operators Handbook
The documents of this Handbook that should be read before starting this document are:
--- Introduction manual

1.2
1.2.1

Terminology
Acronyms and abbreviations

Refer to the Section Introduction manual.


1.2.2

Glossary of terms

Refer to the Section Introduction manual.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

6/51

MAINTENANCE INTRODUCTION

2.1

Introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The maintenance procedures consist of the following steps:

ED

Maintenance of the PC.

Problems with Craft Terminal (shut-down and restart of the PC).

Corrective Maintenance (Troubleshooting).

Unit replacement with a spare.

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

7/51

3
3.1

MAINTENANCE OF THE PC
Introduction

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

With regard to maintenance PC, refer to the constructor's documentation.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

8/51

4
4.1

PROBLEM WITH CRAFT TERMINAL


Purpose of the procedure

This procedure describes the Shutdown and restarts the PC should the Craft Terminal Software Product not
be working properly or not responding to the operator's commands.
In order to shut down the PC execute the command: start>shut down
A window (Windows NT Security user dialog) is displayed. It permits to shut down the computer or restart it.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The same window is displayed pressing he keys <Ctrl> + <Alt> + <Del> simultaneously.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

9/51

CORRECTIVE MAINTENCE (TROUBLESHOOTING)

5.1

Purpose of the procedure

Troubleshooting involves the detection, location and correction of failures in the equipment and the
replacement of the defective parts.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

5.2

Troubleshooting organization

The troubleshooting procedure is carried out with the help of some flow-charts and tables, reported
hereinafter. Anyway this method does not deal with the following aspects (which are to be deduced in other
ways):

Faulty electronic alarm indication, processing and detection circuits

Faulty wiring (back-panel, connectors, etc.)

The following interfaces are present to troubleshoot the equipment:

Q3 interface for Telecommunication Management Network

F interface for Craft Terminal (Local or Remote)

Remote Alarm for Supervisory Center

LEDs on the units of the NE

Usually maintenance is firstly done via software (TMN or Remote Craft Terminal) to locate the faulty
equipment and the faulty unit or the faulty path and then on site to physically solve the trouble.
The Maintenance can be done:

From a TMN network management center

From a Remote Craft Terminal (RCT) management center

From a station supervisory center

On site

TMN network management center: by means of the TMN the maintenance technician can see the alarms
sent by each equipment of the managed network (see the relevant TMN handbooks).
Remote craft terminal: the operator, connected to a local NE, can remotely manage and troubleshooting a
network composed of max 32 NEs included itself. This handbook is used.
Station supervisory center: the maintenance technician refers to the Remote Alarms received from the
equipment in a centralized office of the station i.e.:

T URGENT (MAJOR and CRITICAL), T NOT URGENT (MINOR): remote alarms pertaining to the
urgent, not urgent alarm type.

TOR, TAND: remote alarms respectively due to the decrease or loss of one or both station power
supply DC voltages.

INT: Remote alarm pertaining to the local (internal) alarm type

When a second CONGI unit is used the following remote alarms are added:

ED

TORC, TANC: remote alarms respectively due to the loss of +3,3V generated by the on board
converter in of one or both the CONGI units.

IND: Indeterminate alarm synthesis. Indicates synthesis of alarms not associated to others severities.
Not operative.
03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

10/51

TUP: remote alarm due to microprocessor fault in the COMPACT ADM unit

LOSQ2: remote alarm due to loss of communication with Mediation Device. Not operative.

Depending on the supervisory center organization, it is possible to locate the equipment in troubles and to
detect the failure type and source.
On site: the operator is on site in case:
1) The equipment is not managed by a TMN or by a Remote Craft terminal (RCT)
2) The equipment is not reachable by the remote manager (TMN or RCT) and is therefore isolated

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

3) Link problems are present


4) The trouble has been located and a substitution is necessary
In case 1), 2), 3), the alarmed equipment is checked by means of the local Craft Terminal and of rack LED
indications and station buzzers.
The NE is provided with LEDs, which indicate:
Units Alarms:
Each port card or access card of the equipment is provided with a bicolor LED (green/red) on the front cover
plate.
This LED indicates:

When red, internal failure (indicates that the unit concerned must be replaced)

When green, in service unit

Centralized Equipment Alarms:


All the alarms detected on the units are collected by the COMPACT ADM unit which will deliver centralized
optical indications (by means of LEDs on its front cover plate). Specifically, from the top to the bottom:

Red LED: detection of an urgent (MAJOR and CRITICAL) alarm

Red LED: detection of a not urgent (MINOR) alarm

Yellow LED: alarm condition ATTENDED

Yellow LED: detection of an ABNORMAL operative condition. Type: active loopbacks, forcing the
unit into service, laser forced ON or OFF, try to restore after ALS

Yellow LED: detection of an indication (WARNING) alarm

The analysis of these LEDs permits to detect the alarm type (Urgent - Not Urgent - Indication) and relevant
condition (Abnormal condition, Attended).
In case of urgent or not urgent alarm, after having located the alarmed equipment, the alarm condition can
be "attended" by pressing the relevant alarm storing push button on the COMPACT ADM unit.
This condition causes:

On the rack
The YELLOW LED to light up
The RED LED to go off
On the front cover plate:
Yellow LED (ATTENDED) to light up
Red LEDs NOT URGENT (MINOR) and URGENT (MAJOR and CRITICAL) to turn off (free
to accept other alarms)

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

11/51

If both LEDs are on, the Attend command should be given twice: one for attending the NOT URGENT
(MINOR) alarm and one for attending the URGENT (MAJOR) alarm.

5.3

On site Troubleshooting

The trouble-shooting operation proceeds according to the information indicated in the flow-charts:

Figure 1.: General flow-chart

Figure 2.: Power supply alarm

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

As indicated in the flow-charts the troubleshooting operation is done by means of the Craft Terminal, and of
the optical indicators (LEDs) present on the NE.
The Craft Terminal is cord-connected to the relative connector on the COMPACT ADM unit front cover plate
(F interface).
The Craft Terminal applications provide detailed information on the alarm state thus facilitating fault location
and subsequent removal.
To correctly execute the troubleshooting operations the technician must know the exact equipment
configuration (see Equipment Configuration applications on the Craft Terminal).
The aim of the flow-charts which follow and of the maintenance tables is to locate the faulty unit and to
replace it with a spare as well as to locate a failure along the link.
The flow-charts/tables should be also consulted when the unit LEDs flash, because the flashing condition
might be due to external alarm causes usually related to line problems.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

12/51

Figure 1.

ED

03

General Flow-chart for on site troubleshooting

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

13/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

WARNING!

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Before removing CONGI unit from subrack, switch-off the relevant Station Battery Fuse Breaker present at
the top of the Rack or in the Station Distribution Frame; subsequently remove the station battery cable if
necessary and then extract the CONGI unit.

Figure 2.

Power supply alarm

N.B. IF THE REMOTE ALARMS ARE NOT UTILIZED CHECK FOR PRESENCE OF STATION POWER
SUPPLY. SHOULD IT HAVE FAILED THEN ALL THE UNITS LEDS WILL BE OFF (FOLLOW OUTPUT
YES OF THE FLOW-CHART). IF POWER SUPPLY IS PRESENT PROCEDE WITH OUTPUT NO.

5.4

Troubleshooting by means of the Craft Terminal.

The troubleshoot proceeds checking the detailed information on the NE alarm by means of the craft terminal.
The information on the NE alarm will be mainly obtained by means of the craft terminal through the Alarm
Surveillance data and the alarms/status indications presented in the various views, depending on the level
of the structure under observation.
Navigation across the various level views is done from higher to lower levels, by double clicking on the
objects (see instructions on "NE management" section).
The NE hierarchy is organized in the following order: NE > rack > subrack > board > port > TP.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

14/51

The troubleshoot procedure with the Craft Terminal consists of the following steps:
a) The alarms/status view organization for the equipment is shown in Figure 2.. Observe the active
alarms on the Severity Alarm Synthesis, Domain Alarm Synthesis and Management States
Control Panel always present on the window (it resumes all the NE alarms).
Table 3. Describes the meaning of these alarms/statuses and the relevant maintenance actions.
b) In case of alarm presence, access the Alarm Surveillance to troubleshoot. This application
gives the details of the detected alarms and helps for their localization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Para 1.1.4 describes this view.


c) It is possible to analyze the detailed alarm presence on the TPs of each ports of the NE,
following the indication of Para 1.1.5.
d) It is also possible to check alarm and status at Board view; Subrack view and Equipment view
are also supplied following the indication of Para 1.1.6 and Para 1.1.8.
e) Eventual housekeeping alarms can be localized following the indications given in Para. 1.1.9.
f) These above said paragraphs describe general aspect of alarms meaning and relevant
maintenance actions that can be done with the information given in the applications.
g) The history of past events can be obtained by means of the Event log option of the Diagnosis
pull down menu (see "NE management" section).
Troubleshooting with Automatic Laser Shutdown
The Automatic Laser Shutdown (ALS) is used to protect the operator who is working with the optical fiber.
When the ALS is active, it may be difficult to detect the link failed.
To locate it, it is necessary to "force on" the ALS, thus enabling the optical power transmission on the
opposite direction of the failed link.
WARNING: During this phase the operator has to pay attention when working with fibers and connectors.
The ABNORMAL indication informs the operator of the ALS forced condition.
After having completed the maintenance, enable the ALS.
The ALS states are indicated in the port view.
5.4.1

Preliminary Concepts and Definitions

The following concepts and definitions are considered useful to facilitate maintenance operations with the aid
of the previously indicated tables.
The various units specified in the synchronous multiplexing hierarchy imply structuring the Transmission
network into three levels (sublevels of the physical OSI level):

ED

Transmission bearer level. It is the support for the path level and can be further split into physical
level (Transmission media) and Transmission section level. The sections can be either regenerator
or multiplexer and utilized for specific functions associated to the EOW channels of the SDH frame.
The interface alarms (or section alarms, indicated in the tables) belong to this level (example: Line
LOS, LOS, B2etc.).

Path level It concerns the data transfer between the access points and the path. It does not depend
on the service or on the type of Transmission media. It constitutes the circuit level support. The path
can be either lower order (LO) or higher order (HO) depending on the capacity of data transferring.
Like the regenerator and multiplexer sections, the paths too have specific functions associated to the
EOW channels of the SDH frame. The alarms listed in the cited tables, where path level
troubleshooting is required, belong to this level (example: TU AIS, TU LOP).

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

15/51

Circuit level. This level concerns the transfer of information between the access points and the
circuit proper. It is a direct support for the telecommunication services. It superimposes the SDH
function and is considered as the transport agent hence no SDH order-wire channel associated
functions are required. An example of this level alarm is Tributary LOS.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The above level structuring in the Transmission network is depicted in Figure 3.

Figure 3.

5.4.2

ED

Transmission network level structure

Alarms/states view Organization (subrack view)

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

16/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 4.

Alarms/status view Organization (subrack view)

The critical (CRI) or major (MAJ) alarms indicate severe alarms that could have impact on the current
traffic (interruption or degrade). Thus requiring a rapid intervention to restore the regular working condition
of the equipment.
A message under the mouse facility provides the alarm or status complete denomination. A message
appears in the message area in the bottom left corner of the view.
5.4.3

Alarm synthesis indication

Alarms and Statuses synthesis are given in all the screens.


The alarms CRI, MAJ, MIN, WNG, IND are part of the Severity Alarms Synthesis area, presented in Table
3.
The alarms EXTP, EQP, TRNS are part of the Domain Alarms Synthesis area, presented in Table 4.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

17/51

The alarms SUP, LAC, COM, OS, MGR, NTP and AC are part of the Management States Control Panel,
presented in Table 5.
All these indications (except for SUP, LAC, COM, OS, MGR, and NTP) are the summaries of particular types
of alarms detected by the equipment, hence the specific cause of alarm is to be found as indicated in the
following paragraphs: 1.1.4, 1.1.5, 1.1.6, 1.1.7, 1.1.9.
Table 1. Reports the association between the colors of the Alarms and their Severity.
For the Domain Alarms Synthesis the color corresponds to the highest severity among the set of the active
alarms for the relevant domain, according to the same rules of previous Tableau 1.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Tableau 2. Reports the colors of the Management States Control Panel when not in "normal" condition.
Table 1. Alarms colors and Severity association

Alarm Color

Severity

RED

CRITICAL

ORANGE

MAJOR

YELLOW

MINOR

CYAN

WARNING

WHITE

INDETERMINATE

GREEN

NO ALARM

Table 2. Alarm Synthesis indication

Mnemonic

Alarm/Status
Description

CRI

Critical alarm

Maintenance
Synthesis of alarms that needs immediate troubleShooting (typical: NE isolation). NB1.
See detailed indication in the following Para.

MAJ

Major (Urgent) alarm Synthesis of alarms that needs immediate troubleshooting. NB1. See detailed indication in the following
Para.

MIN

Minor (Not urgent) alarm Synthesis of alarms for which a delayed


troubleshooting can be defined. NB1. See detailed
indication in the following Para.

WNG

Warning alarm

IND

Indeterminate alarm

Synthesis of alarms due to failure of other NE in the


network. NB1. See detailed indication in the following
Para.
Synthesis of alarms not associated to the previous
Severities. Not operative. See detailed indication in
the following Para.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

18/51

Table 3. Domain Alarm Synthesis indication


Mnemonic

Alarm/Status
Description

EXTP

External Point
(Housekeeping alarm)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

SYNC

Maintenance
Check the relevant station alarm associated to the
Input housekeeping indication. See detailed indication
in the following Para.

Synchronization alarm Synthesis of alarms of the Synchronization domain.


See unit detailed indication in the following Para.

EQP

Equipment alarm

Synthesis of alarms of the Equipment domain.


See unit detailed indication in the following Para.

TRNS

Transmission alarm

Synthesis of alarms of the Transmission domain.


See unit detailed indication in the following Para.

Table 4. Management States Control Panel.


Mnemonic

Description

SUP

Supervision state

Maintenance
GREEN: NE is under supervision.
BROWN: NE is not under supervision.
Used in the OS.

Local Access State

GREEN: Indicates that the Craft Terminal has the OS


permission to manage the NE (granted).
CYAN: Indicates that the Craft Terminal has not the
OS permission to manage the NE (denied).

COM

NE
GREEN: Identifies the Enable operational state of
unreachable/unreachable the connection between NE and Craft Terminal (SDH
service link up)
RED: Identifies the Disable operational state of the
connection between NE and Craft Terminal (SDH
service link down)

OS

Operational System
Isolation

GREEN: Indicates that the N.E. is not managed by


the 1353SH
CYAN: Indicates that the N.E. is managed by the
1353SH.

MGR

Manager level

GREEN: Indicates that the N.E. is not managed by


the 1354RM
CYAN: Indicates that the N.E. is not managed by the
1354RM

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

19/51

NTP

Network Time Protocol

GREEN: NTP protocol enabled and both NTP servers


(main and spare) are unreachable.
BROWN: NTP protocol disabled.
CYAN: NTP protocol enabled and at least one NTP
servers (main or spare) are reachable.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

AC

Abnormal Condition

GREEN: normal operating condition.


CYAN: detection of an ABNORMAL operative
condition. Type: active loopbacks, forcing the unit into
service, laser forced ON or OFF, try to restore after
ALS

NB1: Alarm Severity Assignment Profile can modify the assignment of each alarm root to the various
syntheses.

5.4.4

Alarm Surveillance (AS)


In case of alarm presence, access the Alarm Surveillance (AS) to troubleshoot. For this purpose
select the Diagnosis pull down menu. With the Alarm pull down menu (see Figure 3.). It is possible
to show all the NE Alarms or filter the alarms report, for example displaying only the alarms of a
specific domain (i.e. only alarms of the Equipment domain).

Figure 5.

Alarm pull down menu

After the selection a list with a synthesis of the Alarm Surveillance is presented and immediately after also
the detailed list of the Alarm Surveillance (see Figure 6.).
In the synthesis list it is possible to filter the data to show with the detailed view, double clicking on the
selected row of the sublist of Figure 6.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

20/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 6.

Alarm Surveillance

Detailed information of each alarm is supplied.


The alarms scenario is indicated by the colors of the alarms and by the information displayed in the table.
For instance, if an alarm is still active, the whole row has the same color of its relevant "Perceived Severity";
else if it has been cleared, the color of the row is green (except the "Perceived Severity"). The same
information is reported in the "Clearing Status" column.
In the following are shortly described the main information obtained in the AS view, starting from the left
column:

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

21/51

Table 5. Alarm Surveillance information general description


TITLE
- Perceived Severity

DESCRIPTION
The severity assigned to the alarm is indicated, with the relevant
color, i.e.: MAJOR, MINOR, WARNING

- Event date and time Indicates year, month, day and hour of the alarm.
- Friendly Name

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- Event Type
- Probable Cause
- Reservation Status
- Clearing status

Identify the rack, board, port, and TP in which the alarm is detected,
i.e.: / r01sr1sl09/#port01-CE1S
Indicates the family type of the alarm as subdivided in the ASAP
list, i.e.: EQUIPMENT, COMMUNICATION,
The fault/problem is indicated, i.e.: loss of signal, transmitter
degraded, replaceable unit missing, resource isolation, ...
Indicates if the alarm is reserved (RSV) or not (NRSV) according
security management.
Indicates if the alarm condition is terminated (CLR) or is still active
(NCLR). If cleared it has a green background,

- Acknowledge status Indicates if the alarm has been acknowledge (ACK) with the button
on the COMPACT ADM unit or not (NACK).
- Correlated notification Not used
flag
- Repetition counter

Not used

The information supplied helps the operator during the troubleshooting operation.
Table 6. Supply general indications of alarms meaning and relevant maintenance actions that can be done
with the information given in the applications.
The maintenance action must take into account the board where the alarm is detected.
External Points alarms are referred to the input external point relevant to the Housekeeping signals. They
are available for the customer by connecting them to a dedicated subrack connector.
Detailed description of this application is given in the AS Operator's Handbook.
Table 6. General aspect of alarms meaning and relevant maintenance actions
PROBABLE CAUSE

MAINTENANCE

NAME AND/OR ACRONYM


OF DISPLAYED ALARM
Loss of signal (LOS)

Check line

Transmitter Signal (TF)

Replace unit

Transmitter degraded (TD)

Replace unit when possible (laser degrade)

Loss of frame (LOF)

Check line (alignment problems due to line error)

AIS

Check connected equipment

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

22/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Excessive BER (EBER)

Check line (excessive line BER)

Degraded Signal (DS)

Check line (line signal degrade)

Loss of Pointer (LOP)

Check line

Payload Mismatch (PLM)

Configuration error

Far End Received Failure (FERF)

Check far-end equipment

Server Signal Failure (SSF)

Check the entire TU path. Alarm indicates AIS signal received on the
TU

Frequency offset (DRIFT)

Check reference and connection between it and the equipment

Loss of timing source (LOSS)

Check reference and connection between it and the equipment

Resource Isolation

Check connection between NE and Craft Terminal

Communication Subsystem

Check Communication configuration (LAPD)

Isolation (CSF)
Unequipped (U)

Configuration error

Referred to Signal Label


Unconfigured Equipment

Unit inserted but not declared

Present (UEP)
Internal Communication Problem

Reset NE. If persists substitute Compact ADM unit

URU - Underlying Resource

Insert the board

Unavailable
PM_AS- Performance

Check path / line section interested to the indication.

Monitoring Alarm Synthesis


CPE-Communication protocol

Check MSP protocol (architecture type, switch fail)

error
LOMF - Loss Of MultiFrame

Check payload structure

PTM- Path Trace Mismatch

Not operative in current release

AUXP

Check far-end equipment

Remote Node Transmission

Check far-end equipment

error (RNTE)

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

23/51

Table 7. Board Alarm

NAME AND ACRONYM

BOARD

OF DISPLAYED ALARM

ACRONYM

Unit missing
(RUM)

A2S1
A21E1
A3E3
A3T3
A4ES1
ETHATX
ETHMB
GETHAG
HPROT
L41
L41N
L42
L42N
P3E3/T3
P4ES1N
P4S1
P4S1N
P21E1
P21E1N
P21E1NM4
P63E1
P63E1N
P63E1NM4
P8DCN
S41
S41N
ES18FE
ES48FE
COADM1
COADM2
COWLA2
COMDX8

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

MAINTENANCE

Unit Problem
(RUP)

Unit type mismatch


(RUTM)

Replace unit

Insert right unit (unit inserted into a slot set


with another type of
unit)

PR16

Unit missing

Insert missing unit

(RUM)
Unit Problem

Replace unit

(RUP)
Unit type mismatch
(RUTM)
Power Problem

Insert right unit (unit inserted into a slot set


with another type of unit)
Replace unit

(POP)
Pump failure

Replace unit

(PF)

ED

Insert missing unit

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

24/51

Enclosure Door Open


(EDO)

Check that the protection cover in front of


the unit has been correctly placed.

Unit missing (RUM)

Insert missing unit

Unit Problem (RUP)

Replace unit

Unit type mismatch (RUTM)

Insert right unit (unit inserted into a slot set


with another type of unit)
BST10
BST15
BST17

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Pump failure (PF)


Enclosure Door Open (EDO)

Check that the protection cover in front of


the unit has been correctly placed.

Unit missing (RUM)

Insert missing unit

Unit Problem (RUP)


Unit type mismatch (RUTM)

GETHMB
ES18FE
ES18FX
ES48FE
ES16

Internal communication problem


(ICP)

Unit missing (RUM)


Unit Problem (RUP)
Unit type mismatch (RUTM)
Version Mismatch

SYNTH16
SYNTH16N
PREA1GBE
PREA4ETH
ATM8X8
ATM4X4

Internal Communication problem


(ICP)
Unit missing
(RUM)
Unit Problem
(RUP)
Unit type mismatch
(RUTM)
High Laser Temperature
(HLT)

S161
S161N
S161ND
L161
L161N
L161ND
L 162
L162N
L162ND
I161ND

Cooling Fans Failure


(CFF)
FAN
Unit missing
(RUM)
Unit missing
(RUM)

ED

Replace unit

03

Replace unit
Insert right unit (unit inserted into a slot set
with another type of unit)
Internal dialogue problem in the unit. It
indicates a temporary condition which will
be restored. If the condition persists it is
due to a unit hardware failure: in this case
it will activate the RUP alarm
Insert missing unit
Replace unit
Insert right unit (unit inserted into a slot set
with another type of unit)
Update software version by means of SW
download
Internal dialogue problem in the unit. It
indicates a temporary condition which will
be restored. If the condition persists it is
due to a unit hardware failure: in this case
it will activate the RUP alarm
Insert missing unit
Replace unit
Insert right unit (unit inserted into a slot set
with another type of unit)
Replace unit
Check the fan units and substitute the
faulty one
Insert missing unit

CONGI

Insert missing unit

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

25/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Unit Problem
(RUP)

Replace unit

Unit type mismatch


(RUTM)

Insert right unit (unit inserted into a slot set


with another type of unit)

LAN problem
(LAN)

This alarm type is present only on


1650SMC or 1660sm.
Check LAN interconnection or substitute
CONGI unit

Battery Failure
(BF)

According to the CONGI slot check the


station battery.(Battery A or Battery B)

Fuse Failure
(FF)

Substitute the fuse on the CONGI unit.

Unit missing
(RUM)
Unit Problem
(RUP)

Insert missing unit


Replace unit

Unit type mismatch


(RUTM)

SERGI

Battery Failure
(BF)
Fuse Failure
(FF)

Insert right unit (unit inserted into a slot set


with another type of unit)
Check the Station Battery connected to the
unit
Substitute the fuse on the CONGI unit.

Table 8. Module Alarm

ED

NAME AND ACRONYM

MODULE

OF DISPLAYED ALARM

ACRONYM

03

MAINTENANCE

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

26/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Unconfigured
Equipment Present
(UEP)

5.4.5

ICMI
IS1.1
IL1.1
IL1.2
MM1
IS4.1
IL4.1
IL4.2
1000B
1000B
100B
OHI
OLIN
OHMM
OLMM
SS162E
SL162E
SS162C
SL162C
SL162
SL161
SI161
SS161

Insert missing unit

Port View alarms

It is also possible to analyze the detailed alarm presence on the TPs of each ports of the NE, following the
indication of the Port View chapter on the previous Section of this Handbook.
Figure 7. To Figure 9 is an example of a Port view.
For each TP of the Port a detail of the relevant alarms is presented.
On the port view the messages displayed at the bottom provide information about:
-

MSP protection (if enable)

Automatic Laser Shutdown state

State of the connection for Ethernet port (available only if an Ethernet port has been selected)

A message under the mouse indicator provides the name of the alarm or object on which it is located, in this
way facilitating the identification of the alarm or status or object.
The non-alarmed condition of an alarm icon is represented by a green color and a "-" sign in the box.
The alarmed condition is represented by the color of its severity (as assigned by the ASAP) and an "X" signs
in the box.
The alarms, which can be found in the Port view, are listed in Table 7. Where the relevant maintenance
actions are reported too.
The information regarding ALS states and Laser state useful for operators safety purpose are
reported in the following:
ALS states:
Inactive = No ALS has been activated (Off) or the laser has been Forced ON/OFF.
In test = the laser restart has been automatically activated.
ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

27/51

Active = The ALS has been activated (On).


Undefined = The ALS is not present (not created).
Laser state:
On = all OK or ALS not present (not created).
Off = Laser off (when ALS is created).
Forced on = ALS forced on by operator command.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Forced off = ALS forced off by operator command.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

28/51

Figure 7.

ED

03
Example of SDH Port View alarms (with MSP schema)

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

29/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 8.

ED

03
Example of ATM Port View alarms

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

30/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 9.
5.4.6

Example of Ethernet Port View alarms

Board view alarms and states

The alarm and status indications at Board level can be obtained, following the indication of the Board View
chapter on the previous Section of this Handbook.
The alarm and status indications depend on the unit type; for example SDH units is organized on two levels
of presentation (in the first is selected one of the available ports) and each view contains dedicated
indications.
An alarm box is displayed on each port, to indicate whether the port is alarmed.
An indication in the "message/status area" provides information about the board Administrative State: "inservice" or "out-of-service".
The alarms of the board are reported at the bottom of the "message/status area", by means of various boxes
containing relevant acronyms.
ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

31/51

The non-alarmed condition of an alarm icon is represented by a green color.


The alarmed condition is represented by the color of its severity (as assigned by the ASAP).
A message under the mouse indicator provides the name of the alarm or object on which it is located, in this
way facilitating the identification of the alarm or status or object.
In the view is present the Administrative State information: "in service" or "out of service".
The alarms, which can be found in the Board view, are listed in Table 7., where the relevant maintenance
actions are reported too.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In the view can also be present EPS indications.

Figure 10.
ED

03

Example of SDH Board View alarms and status

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

32/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 11.
5.4.7

Example of PDH Board View alarms and status

Subrack and Rack view alarms

The alarms and status indications at subrack and rack level can be obtained, following the indications given
on the previous Section of this Handbook ("NE management").
An alarm box is displayed on each board, to indicate whether the board is alarmed. This board alarm
summarization is activated when one of the board alarms (those reported at the bottom of the Board view) is
active.
A "lock" symbol on a board indicates that it is "in-service". Else, the lack of this symbol indicates its "out-ofservice" state. (Administrative State information).
A message under the mouse indicator provides the name of the alarm or object on which it is located, in this
way facilitating the identification of the alarm or status or object.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

33/51

Figure 12.

ED

03
Example of Subrack view alarms and status

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

34/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 13.
5.4.8

Example of Rack view alarm and status

Fans Subrack alarms view

To obtain Fan Subrack alarms indications click twice with the mouse on the relevant subrack drawing in the
rack level view.

ED

Battery Failure (BF): check that the station battery cables are right connected

Cabling Problem (CAP): check that the alarms cable between the Fans Subrack and the CONGI unit
is right connected; check also the configuration in the Equipment menu. (Connected FAN to
CONGI#1 or connected FAN to CONGI#20)

Temperature Out Of Range (TOOR): verify the Fan unit alarm and in presence of faulty substitute
the relevant unit; clean also the Dust filter if necessary.

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

35/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 14.
5.4.9

Fans subrack alarms view

Equipment View alarms

The alarm indications at Equipment level can be obtained, following the indication of the Equipment View
chapter on the previous Section of this Handbook.

Fuse Failure (FF): Substitute the fuse in the CONGI unit and search for a cause

AND Battery Failure (ABF): Failure of the Service Power Supply connected to the CONGI Rack
connector.

Backplane Failure (BKF): Substitute the Termination BUS

Specific Hardware Diagnostic (SDH): Indicate the presence of link failure between the MATRIX and
one of the units; for details choose the Internal Link Monitor option of the Diagnosis menu.

These alarms can be observed at OS level.


ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

36/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 15.

Example of Equipment View alarms and status

5.4.10 External Points alarms (Housekeeping)


The alarms and status indications relevant to External Points (housekeeping) can be obtained, following the
indication of the External Points chapter on the previous Section of this Handbook.
The external state represents the alarm state. "On" when the alarm is raised, else "Off".
If the external point is active (On), a red flag is represented near the state of the concerned point.
In case of input point the alarm state is reported also in the user label column, by the box near its name:
Green color and sign "-" ---> means non-alarmed condition.
The change of color, as assigned by the severity (ASAP) ---> means alarmed condition.
ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

37/51

Figure 16.

ED

03
Example of External Points alarms and status

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

38/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

UNIT REPLACEMENT WITH A SPARE

No particular indication is given as to spare handling, which is left to the Maintenance Administration.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The replacement procedures are executed as follows:


-

Hardware set the spare unit exactly as the unit to replace. Settings are specified in the MS
documents. Here a layout figure indicates the exact location of all the setting arrangements and a
table relates the operations to achieve with the settings. The cited documents are enclosed in the
Technical Handbook.

Simply replace those units not provided with any software settings

With regard to the COMPACT ADM (also called SYNTH or SYNTHN) unit refer to paragraph 6..

With regard to the ATM MATRIX 4X4 unit refer to paragraph 6.2.

With regard to the IP MATRIX unit refer to paragraph 6.3.

When upgrading equipment with New Hardware (for example SYNTHN unit) that substitutes the
old units (for example SYNTH unit), follow the indication given in paragraph 7.

WARNING: In order to avoid short Circuit, before substituting the CONGI unit,
Switch--off the relevant Station battery fuse breaker. Subsequently remove the Station
Battery cable and extract the CONGI unit.

WARNING: before inserting the new spare unit carefully checks the integrity of the
relative connectors.
Dont insert the units that have been damaged during the transport/storing or in a phase
before their replacing.

6.1

COMPACT ADM unit replacement

N.B. In this paragraph for COMPACT ADM is generically intended one of the following unit:
-

SYNTH16

SYNTH16N

Various procedures are utilized to replace a COMPACT ADM faulty unit. They depend on the
following maintenance conditions:
-

EPS protection of the COMPACT ADM unit


o

EPS present or not (typically present)

Failure on the Main board

Failure on the Spare board

Type of spares available:


o

ED

03

Spare without software installed. This is the normal condition.

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

39/51

Spares with installed software, belonging to the same type of equipment and with SW
release identical to the unit to replace.

Spares with installed software, belonging to the same type of equipment but with SW
release differing from the one of the unit to replace, or belonging to other types of equipment
or unknown.

CONGI unit version (read NOTES in Figure 17. and Figure 18.)

MIB store in the Craft Terminal or O.S.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

The flow charts of Figure 17. And Figure 18. Illustrates the procedures to follow
For the COMPACT ADM substitution.
The procedure aim is to replace the faulty unit without causing configuration changes and/or
unwanted faults; when not possible this is indicated in the flow chart.

Replacement problems:
1 When replacing the COMPACT ADM unit the traffic of the two SDH ports is lost when not SNCP protected.
Then it is suggested to replace in low traffic condition.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

40/51

Figure 17.

ED

03

COMPACT ADM unit replacement (EPS protected)

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

41/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 18.

ED

03

COMPACT ADM unit replacement (EPS not protected)

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

42/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

2 When plug-in a COMPACT ADM unit and supervision it with NM, if the following warning box
appear.

Then it is suggested to set the NE Time in CT.


Because when NTP is enable, and the board initial time isnt changed firstly, sometimes the DCC
channel doesnt work, the NE will be lost from NM.
The procedure as following:
Select the NE Time... option from the Configuration pull down menu.

Figure 19.

Consulting and/or setting the local NE time

The following dialogue box is opened from which you can set the local NE time.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

43/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 20.

6.2

NE Time dialogue box

ATM MATRIX 4X4 unit replacement

Two different procedures are available for ATM MATRIX 4X4 substitution according to the EPS schema.
The flow-charts of Figure 19. Illustrates the procedures to follow for the ATM MATRIX 4X4 when it is not EPS
protected.
The flow-charts of Figure 20. Illustrates the procedures to follow for the ATM MATRIX 4X4 when it is EPS
protected.
The procedure aim is to replace the faulty unit without causing configuration changes and/or unwanted faults.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

44/51

Figure 21.

ED

03
ATM MATRIX 4X4 unit replacement without EPS protection

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

45/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 22.

6.3

ATM MATRIX 4X4 unit replacement with EPS protection

IP MATRIX unit replacement

For IP MATRIX unit replacement refer to the specific Operators Handbook.

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

46/51

UPGRADING WITH NEW HARDWARE

In the next paragraphs is indicated the procedure to follow when upgrading an equipment with New
Hardware.
The new Hardware is identifying by the N letter at the end of the acronym unit (for example SYNTHN is the
new version, SYNTH without N is the old version).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

This procedure permits, if the equipment is EPS protected and inserted in a protected network (linear or ring
protection), to maintain the system in service.

7.1

SYNTH substitution with SYNTHN

According to the EPS and SNCP SYNTH protection scheme different procedure are available:
[1] Upgrading with a new SYNTHN EPS not protected
Substituting the old SYNTH all the traffic is lost!

ED

Remove the old SYNTH in slot 6 from the subrack

Before inserting the new SYNTHN in subrack slot 6, follow the instruction described in Figure 21.. At
the end of the procedure a RUTM (unit type mismatch) alarm will be present.

On Craft Terminal in the Subrack level view select the SYNTHN unit in slot 6

Select the Modify option from the Equipment menu and select the SYNTHN acronym from the list
then click on ok.

Verify that the RUTM alarm disappear

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

47/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 23.

Upgrading with a new SYNTHN EPS not protected

[2] Upgrading with a new SYNTHN EPS protected


Supposing that the STM-16 ports are not network protected, their traffic will be lost during
the substitution; the traffic of all the other board will not be lost.
ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

48/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

Remove first the old SYNTH in slot 15 from the subrack

Insert the new SYNTHN into the subrack slot 15; a RUTM (unit type mismatch) alarm will be present.

On Craft Terminal in the Subrack level view select the SYNTHN unit in slot 15

Select the Modify option from the Equipment menu and select the SYNTH acronym from the list
then click on ok.

Verify that the RUTM alarm disappear

Force the EPS Switching on SYNTHN in slot 15 by selecting the Switch option from the EPS menu.
For details see the paragraph Switching EPS in the NE MANAGEMENT section of this Handbook.

Remove the old SYNTH in slot 6 from the subrack

Before inserting the new SYNTHN in subrack slot 6, follow the instruction described in Figure 22.. At
the end of the procedure a RUTM (unit type mismatch) alarm will be present.

On Craft Terminal in the Subrack level view select the SYNTHN unit in slot 6

Select the Modify option from the Equipment menu and select the SYNTHN acronym from the list
then click on ok.

Verify that the RUTM alarm disappear

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

49/51

Figure 24.

ED

03

Upgrading with a new SYNTHN EPS protected

SC.4 : NE MAINTENANCE

3AL 98253 ADAA

50/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

[3] Upgrading with a new SYNTHN EPS protected with STM-N ports SNCP protected
The procedure is the same of that described on point [2]. But without traffic interruption on the STM-16 ports
present on the SYNTH because SNCP protected.

7.2

P4S1, S-41, L-41, L-42 substitution with P4S1N, S-41N, L-41N, L-42N
During the substitution the traffic carried by the units will be lost if not SNCP protected.

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

In the following an example will be given substituting a P4S1 with a P4S1N; the same procedure can be
applied to substitute the S-41, L-41, L-42 units respectively with S-41N, L-41N, L-42N units.

Remove the old unit (example P4S1) from the subrack

Insert the new unit (example P4S1N) into the subrack slot previously occupied by the old unit; on
Craft Terminal a RUTM (unit type mismatch) alarm will be present.

On Craft Terminal in the Subrack level view select the slot where the new unit has been inserted

Select the Modify option from the Equipment menu and select the acronym of the new unit (in our
example P4S1N) from the list, then click on ok.

Verify that the RUTM alarm disappear

END OF DOCUMENT

ED

03

SC.4 : NE MAINTENANCE
3AL 98253 ADAA

51/51

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Alcatel 1662SMC Rel2.4 Operator Handbook

Alcatel 1662SMC Rel2.4


Download and SIBDL Configuration

03

09/01/2006

Creation

ED

DATE

CHANGE NOTE

Distribution: Internal

Chen Yu
APPROVED BY

PREPARED BY

External

ED

03

SC.5: SIBDL
3AL 98253 ADAA

1/19

LIST OF FIGURES AND TABLES ....................................................................................................................3


1

INTRODUCTION .......................................................................................................................................4
1.1
1.1.1

Document scope...........................................................................................................................4

1.1.2

Target audience............................................................................................................................4

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.2

Scope................................................................................................................................................4

Terminology.....................................................................................................................................4

1.2.1

Acronyms and abbreviations ........................................................................................................4

1.2.2

Glossary of terms..........................................................................................................................4

DOWNLOAD WITH SIBDL .......................................................................................................................5


2.1

Purpose of the procedure ..............................................................................................................5

2.1.1
3

SIBDL download procedure..........................................................................................................5

CONFIGURATION FOR SIBDL ..............................................................................................................14


3.1

ED

Purpose of the procedure ............................................................................................................14

3.1.1

Remote Access Service configuration (only needed for Windows NT environment) .................14

3.1.2

Serial Cable Modem configuration for Windows NT environment..............................................14

3.1.3

Serial Cable Modem configuration for Windows 2000 environment...........................................14

03

SC.5: SIBDL
3AL 98253 ADAA

2/19

LIST OF FIGURES AND TABLES


Figure 1. SIBDL download procedure - step 1 ...................................................................................................6
Figure 2. SIBDL download procedure - step 2 ...................................................................................................7
Figure 3. SIBDL download procedure - step 3 ...................................................................................................8
Figure 4. SIBDL download procedure - step 4 ...................................................................................................9

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 5. SIBDL download procedure - step 5 .................................................................................................10


Figure 6. SIBDL download procedure - step 6 .................................................................................................10
Figure 7. SIBDL download procedure - step 7 .................................................................................................11
Figure 8. SIBDL download procedure - step 8 .................................................................................................12
Figure 9. Serial Cable Modem configuration - step 1.......................................................................................15
Figure 10. Serial Cable Modem configuration - step 2.....................................................................................16
Figure 11. Serial Cable Modem configuration - step 3.....................................................................................17
Figure 12. Serial Cable Modem configuration - step 4.....................................................................................18
Figure 13. Serial Cable Modem configuration - step 5.....................................................................................19

ED

03

SC.5: SIBDL
3AL 98253 ADAA

3/19

INTRODUCTION

1.1

Scope

1.1.1

Document scope

The SIBDL Manual describes the SIBDL application, used to download the NE software via Q or F interface.
The SIBDL (Standard Image Binary Download) procedure contains the following operative descriptions:

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

1.1.2

Download with SIBDL. The complete procedure is indicated. See Chapter on page
Configuration for SIBDL. Configurations to be performed for SIBDL operation are described.
Target audience

The SIBDL Manual is intended for all users.


The documents that should be read before starting this document are:

1.2
1.2.1

1320CT Rel. 1.1 Basic Operator's Handbook

Terminology
Acronyms and abbreviations

Refer to the Section Introduction manual.


1.2.2

Glossary of terms

Refer to the Section Introduction manual.

ED

03

SC.5: SIBDL
3AL 98253 ADAA

4/19

DOWNLOAD WITH SIBDL

2.1

Purpose of the procedure

This procedure describes how to download NE software with the SIBDL (Standard Image Binary Download)
program.
2.1.1

SIBDL download procedure

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Download with SIBDL program is performed in the following phases:

Turn on phase, when activating the NE.


Maintenance phase, when substituting the COMPACT ADM unit with a spare, and the spare one
dont contain software.

ATTENTION:
Download with SIBDL program put the COMPACT ADM unit out of service regarding to the supervision and
control function, while the traffic is not lost.
It must not be executed to download a spare unit that contains software; in this case use the Download
option of the EML-USM, presented in the previous section.
SIBDL tool permits to download the software towards the NE using the Q interface (Ethernet connection) or
the F interface RS232 (serial line) of the NE.
When using the Q interface the time necessary to the operation is reduced to some minute.
WARNING:
In Windows NT environment, it should have configured, before to use SIBDL:

TCP/IP protocol, Protocol Service, TEL NET Accessory, defined by the NT Administrator.
RAS (Remote Access Service) and Serial Cable Modem.

In Windows 2000 environment, it should have configured, before to use SIBDL:

TCP/IP protocol, Protocol Service, TEL NET Accessory, defined by the NT Administrator.
Serial Cable Modem refer in Para Serial Cable Modem configuration for Windows 2000
environment
N.B.

RAS (Remote Access Service) is not necessary in Windows 2000 environment

To download with SIBDL execute the following steps:


1) Connect the Craft Terminal with the NE:

When download by means of Q interface, always connect both the F and Q interface.
When download by means of F interface, connect only the F interface.

2) Start SIBDL, selecting Start > Program> Alcatel> SIBDL"version"> SIBDL


3) In the screen, which appears (see Figure 1.) with the command menu, select "automatic mode"
commands typing 8 and then ENTER.

ED

03

SC.5: SIBDL
3AL 98253 ADAA

5/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 1.

SIBDL download procedure - step 1

4) In the field "source file" at the bottom write the path name of the NE descriptor file (see Figure 2.).
The path name has typically the following format (see the example in the figure):
<Directory>/<NE name and release number>/<file descriptor>
Note: In current release it is possible to download two types of file descriptor according to the following rules:
1. Create the NE software package as explained in the paragraph "NE Software package installation
procedure" NE MANAGEMENT of this Manual.
2. If the software to download manage only the SDH functionality, select the file descriptor in the
directory 1662SMC (example:
/ALCATEL/Q3CT_Pv1.3.05/FTservices/data/1662SMC/2.3.08/1662.dsc)
3. If the software to download manage the SDH+ATM/IP functionality, select the file descriptor in the
directory
1662SMC(example:/ALCATEL/Q3CT_Pv1.3.05/FTservices/data/1662SMCE/2.3.08/1662.dsc)

ED

03

SC.5: SIBDL
3AL 98253 ADAA

6/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 2.

SIBDL download procedure - step 2

5) Press ENTER
6) This step (see Figure 3.) asks for the "IP Address" insertion.
In the field "NE_IP_address [PPP TEL NET]" at the bottom:
- With F interface: write PPP and press ENTER
- With Q interface:

First possibility: write TELNET and press ENTER


In next step, which appears, write the IP Address of the Craft Terminal

ED

Second possibility: write the IP Address of the NE and press ENTER

03

SC.5: SIBDL
3AL 98253 ADAA

7/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 3.

SIBDL download procedure - step 3

7) This step (see Figure 4.) asks if the flash card must be formatted. Type "y" to format the flash card; as
result of this action the program ask for a confirmation (see Figure 5.)

ED

03

SC.5: SIBDL
3AL 98253 ADAA

8/19

Figure 4.

ED

03

SIBDL download procedure - step 4

SC.5: SIBDL

3AL 98253 ADAA

9/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

ED

03
Figure 5.
SIBDL download procedure - step 5

Figure 6.

SIBDL download procedure - step 6

SC.5: SIBDL

3AL 98253 ADAA

10/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

8)Typey.(if the synth16s version is before 2005/01/19,please choose n to improve the download speed.)
(see Figure 6.).
9) Type "y. The screen shows the automatic download evolution with a final message indicating the
completed download (see Figure 7.).

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

On the contrary repeat the procedure.

Figure 7.

SIBDL download procedure - step 7

10) Press ENTER.


11) In the presented screen type 4 (see Figure 8.) and ENTER.

ED

03

SC.5: SIBDL
3AL 98253 ADAA

11/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 8.

SIBDL download procedure - step 8

12) Extract and re-insert the EQUICO unit to complete the operation.
13) Extract and re-insert again the EQUICO unit to complete the operation
14) Run the 1320CT application, execute Start supervision and NE login
15) From Craft Terminal (EML-USM view) execute the normal download procedure:
N.B. Check that no RUTM alarm is present in the slot reserved to the main MATRIXN.
If RUTM alarm is present means the board type inserted in the subrack (typically MATRIXN in this release)
and the board type software configured (typically MATRIX) is not the same; under this condition the user
must change the board type with the Equipment->Set menu.
- Select Init download from Download menu
- Select the SW package to Download and click on OK button
In this condition the download is executed immediately
- Select Unit info from Download menu
- Select the Software Package loaded as explained above and activate it

ED

03

SC.5: SIBDL
3AL 98253 ADAA

12/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

- Press OK to complete the operation

In this condition the download is executed immediately.

ED

03

SC.5: SIBDL

3AL 98253 ADAA

13/19

CONFIGURATION FOR SIBDL

3.1

Purpose of the procedure

This chapter describes the configurations to be performed for SIBDL operation.


3.1.1

Remote Access Service configuration (only needed for Windows NT environment)

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

To install a new modem, the user should have administrator privileges and need the installation CD-ROM of
Windows NT, then execute:

Double click on "My computer" icon on the PC desktop and double click on "Control panel" icon;

Double click on "Network" icon;

Select the folder "Services" in the "Network" window and push the button "Add": start the "Select
Network Service" window;

Select Remote Access Service (RAS) in the dialog box;

Follow the instructions.

3.1.2

Serial Cable Modem configuration for Windows NT environment

To install a new modem, the user should have administrator privileges, then execute:

Double click on "My computer" icon on the PC desktop and double click on "Control panel" icon;
Double click on "Network" icon;
Select the folder "Services" in the "Network" window;

Select "Remote Access Service" and push button "Properties...


Push the button "add" in "Remote Access Setup" window;
Push the button "Install Modem" in "Add RAS Device" window: start the "Install New Modem"
window;
Put a tick against "Don't detect my modem; I will select him from a list" and push the "Next > " button;
Push the button "Have disk... start the window Install from disk;
Push the button "Browse...
Search the folder where SIBDL is installed (Alcatel / SIBDL "version" / SIBDL /) and select the file
"mdmalca.inf", after push the button "Open";

Push the button "OK" in window "Install from disk";


Select the modem named "Serial cable" in the dialog box of window "Install New Modem" and push
the button "Next >";
Put a tick against "Selected ports" and select only one port (the port must be available, i.e. not used
by another RAS modem) and push the button "Next >";

Follow the instructions;


Push the button "OK" in "Add RAS Device" window;
Push the button "Continue" in "Remote Access Setup" window;
Push the button "OK" in "Network" window;

3.1.3 Serial Cable Modem configuration for Windows 2000 environment


To install a new modem, you should have administrator privileges;

ED

03

SC.5: SIBDL
3AL 98253 ADAA

14/19

Double click on "My computer" icon on your PC desktop and double click on "Control panel" icon;
Double click on "Phone and Modem Options" icon and select the "Modems" folder;
Push the button "Add": "Add/Remove Hardware Wizard: Install New Modem" window will appear;
Put a tick against "Don't detect my modem; I will select it from a list" and push the button "Next >";

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 9.

ED

Serial Cable Modem configuration - step 1

Push the button "Have disk... the window "Install from disk" will appear;
Push the button "Browse..."
Search the folder where SIBDL is installed and select the file "mdmalca.inf", after push the button
"Open";
Push the button "OK" on the "Install from disk" window;
Select the modem named "Serial cable" into dialog box from "Install New Modem" window and push
the button "Next >";

03

SC.5: SIBDL
3AL 98253 ADAA

15/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 10.

ED

Serial Cable Modem configuration - step 2

Put a tick against "Selected ports" and select only one port (the serial port must be available, i.e. not
used by another RAS modem) and push the button "Next >";

03

SC.5: SIBDL
3AL 98253 ADAA

16/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 11.

ED

Serial Cable Modem configuration - step 3

The window "Digital Signature Not found" will appear: push the button "Yes", and after the button
"Finish" to end modem installation;

03

SC.5: SIBDL
3AL 98253 ADAA

17/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

Figure 12.

ED

Serial Cable Modem configuration - step 4

At the end, the "Phone and Modem Options" window will display the installed modem

03

SC.5: SIBDL
3AL 98253 ADAA

18/19

Figure 13.

ED

03

Serial Cable Modem configuration - step 5

END OF DOCUMENT

SC.5: SIBDL

3AL 98253 ADAA

19/19

All rights reserved. Passing on and copying of this


document, use and communication of its contents
not permitted without written authorization.

You might also like