Brahma Capacitive-Discharge Ignitors
Brahma Capacitive-Discharge Ignitors
SERIES
CAPACITIVE-DISCHARGE IGNITORS
DESCRIPTION
The devices of this series are capacitive-discharge ignitors
for continuous operation, suitable for gas combustion in
atmospheric burners. The available types essentially differ
for their spark frequency and its energy; remember that the
ignition power of a capacitive-discharge ignitor is directly
proportional to its discharge energy.
Thanks to its high discharge energy the TSC1 is suitable
even for the applications in which normal capacitivedischarge ignitors are not effective. The plastic case and an
internal epoxy resin casting grant an adequate insulation.
Notes:
Remember that an excessively long ignition cable
connected to the ignitor can lead to a discharge energy
reduction, because of the production of a parasitic
capacity between the cable and the nearby ground
planes.
Avoid laying the ignition cable next to other conductors:
energy transfer between close conductors due to
parasitic capacity phenomena could damage connected
devices, especially the electronic ones.
TECHNICAL FEATURES
3968_r02
Power supply
Available
discharge
voltage
Discharge
frequency
Discharge
energy
Power
consumption
Type
TSC
220-240Vac
50-60Hz
20kV
25Hz
2mJ
2 VA
TSC1
220-240Vac
50Hz
20kV
50Hz
9mJ
7,5VA
TSC1
110-120Vac
50-60Hz
20kV
50Hz
3mJ
4VA
TSC1/Z
110-120Vac
50-60Hz
10kV
50Hz
6mJ
4VA
TSC1/F
220-240Vac
50-60Hz
20kV
50Hz
8mJ
7,5VA
1/2
OVERALL DIMENSIONS
INSTALLATION
Connect and disconnect the ignition transformer only
after switching off power supply.
Respect the applicable national and European standards
(e.g. EN 60355-1 / EN 50165 / EN 61558-1-2-3)
regarding electrical safety.
Make sure the earth of the transformer and the earth of
the electrical system are well connected The device can
be mounted in any position.
Avoid placing high voltage cables close to other cables.
Make sure the protection degree is suitable to the
system.
Reduce the ignition cable length to a minimum (this
reduces stray capacitance and the possibility that the
ignition cable acts like an antenna transferring
interference to the nearby cables).
Make ignition cables follow a separate path close to
ground planes (this reduces the influence of interference
on the remaining electrical wires).
Arrange a single earth centre, thus preventing earth
conductors from creating ring paths.
CONNECTION
The power supply connection occurs by means of
6,3X0,8 fast-on connectors; the high voltage part is
connected by means of 2,8X0,5 fast-on connectors..
ATTENTION -> Company Brahma S.p.A. declines any responsibility for any damage resulting from the Customers interfering with the device