End Plates - Worked Examples With Partial Depth End Plate - Example 5
End Plates - Worked Examples With Partial Depth End Plate - Example 5
End Plates - Worked Examples With Partial Depth End Plate - Example 5
DESIGN EXAMPLE 5
Check the following beam to hollow section column joint for the design forces shown using
Blind Bolts to the column.
In this example the tie force is less than the shear force.
The connections should be checked independently for shear forces and tying forces and not for
both forces acting at the same time.
40 40
90 90
70 70
70 70
200 kN 70 70 275 kN
Tying force 70 Tying force
70
40
406 x 178 x 74 UKB 40
Grade S275 10 12 553 x 210 92 UKB
Grade S275
340 kN 550 kN
90 140
Design Information:
Bolts: M20 Blind Bolts
Welds: 6 mm leg length fillet welds
Column: S355
Beams: S275
End plates: S275
72