d5c Ds e 4 2 csm59413-96637
d5c Ds e 4 2 csm59413-96637
d5c Ds e 4 2 csm59413-96637
D5C CSM_D5C_DS_E_4_2
Application Examples
Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills
Press
Press
D5C
D5C
D5C D5C
Detection of Fine Wire or Thin Plate Detection of Loose Screws Detection of Loose Wires
Wire
D5C D5C
D5C
D5C
Steel plate
1.0 mm
D5C
Ground pole
D5C
Paper or cloth
Paper or cloth
Ground surface
1
D5C
Ordering Information
Usable by bending tip of antenna. Ideal for high-accuracy position control.
Features Any actuator can be attached.
Overtravel of 20 mm max. Overtravel of 3.5 mm max.
Coil spring Plunger Free-attachment
Actuator
Specifications
Ratings and Characteristics
Type DC AC
Item Model D5C-1D@0 D5C-1A@0
Degree of protection Equivalent to IP67
Mechanical durability 10,000,000 operations min. (at rated overtravel value)
Supply voltage (operating voltage) 12 to 24 VDC (10 to 30 VDC), (ripple: 10% max.) 100 to 240 VAC (45 to 264 VAC), 50/60 Hz
Rated frequency --- 50/60 Hz
Sensitivity setting range 30 to 100 pF
Current consumption 17 mA max. ---
Circuit --- 2 mA max.
Leakage current
Antenna 1 mA max. 1 mA max.
Response time 2 ms max. 8 ms max.
Output current 200 mA max. (resistive load)
Insulation resistance 50 M min. (at 500 VDC) between lead wires and case
1,000 VAC, 50/60 Hz for 1 min between current-carry- 2,000 VAC, 50/60 Hz for 1 min between current-carry-
Dielectric strength
ing metal parts and non-current-carrying metal parts ing metal parts and non-current-carrying metal parts
Rated insulation voltage (Ui) 1,000 VAC
Pollution degree
3 (IEC947-5-1)
(operating environment)
Protection against electric shock Class II
Proof tracking index (PTI) 175
Switch category D (IEC335)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance 1,000 m/s2 max.
Ambient temperature Operating: 25C to +70C (with no icing)
Ambient humidity 35% to 95%RH
Weight Approx. 110 g (in case of D5C-1DS0) Approx. 120 g (in case of D5C-1AS0)
2
D5C
150 150
Sensitivity (pF)
100 100
0 0
40 25 0 40 70 80 40 25 0 40 70 80
Temperature (C) Temperature (C)
Sensitivity (pF)
100 100
50 50
LED operation
Coil spring actuator indicator
(Stainless steel) O-ring
Contactor Sensitivity adjuster
Caution label
O-ring
Lead wire
Actuator
Case Washer Filled with glass epoxy
Mounting nut
Operating Principle
The limit-type Touch Switch ...the oscillation circuit ...the switching circuit
vibrates at a high frequency. constant changes, operations, and an Use the specified
When an object touches the oscillation stops... output signal is produced. voltage.
antenna...
Feedback circuit
Antenna
Oscillator Detection circuit NOT circuit Power supply
3
D5C
Connections
Output Circuit Diagram
The lead wire colors of the D5C have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.
D5C-1D@0 (DC Model) D5C-1A@0 (AC Model)
Brown (Red)
4.7 k Load
Brown (White)
Switch Switch
main 12 to 24 VDC main Load
circuit Black (White) circuit
100 to 240 VAC
Blue (Black) Blue (Black)
DC Models
Coil Spring
D5C-1DS0
(162.5)
61 (3,000)
101.5 56
*3
51 37
4 Caution label
14 4
Overtravel
Plunger
D5C-1DP0
(85)
61 (3,000)
24 56
*3
37
4 Caution label
Overtravel 4
4
D5C
Free-attachment
D5C-1DA0 (89)
61 (3,000)
28 56
Lock nut *3
14 37
4 Caution label
4
M4 0.7 *1
AC Models
Coil Spring
D5C-1AS0
(177.5)
76 (3,000)
101.5 71
*3
51 52
Caution label
14 4 4
Overtravel
Plunger
D5C-1AP0
(101)
76 (3,000)
24 71
*3
52
Caution label
Overtravel 4 4
Free-attachment
D5C-1AA0 (104)
76 (3,000)
28 71
Lock nut *3
14 52
Caution label
4 4
M4 0.7 *1
5
D5C
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
CAUTIONS Antenna
<Shape and Extension>
Make sure that the antenna does not come into contact If a metal plate is used as an antenna by connecting it to the built-in
with the human body, otherwise an electric shock may or separated antenna of the D5C, the surface area of the metal plate
be received. must be 200 cm2 maximum (Fig. 1). The antenna can be extended,
provided that the total length of the antenna is 1 m maximum (Fig. 2)
and that the bottom of the antenna is at least 10 cm (Fig. 3) away from
the ground. Refer to the illustrations below
Precautions for Correct Use The D5C may be damaged if the antenna is excessively large or
heavy or if the antenna is used in locations with excessive vibration or
Mounting shock. Be sure to check the locations before use.
Do not tighten the nuts with excessive force. Mounting Hole Dimension
Fig. 1 Fig. 2 Fig. 3
The maximum permissible tightening force of
Metal plate
each nut with a washer is 29.4 Nm. 200cm2 max. 1
6
5
1 m max. D5C
2 4
10 cm min.
3
+0.5 Ground
Grounding of Antenna and Sensing 18.5 -0 dia.
1+ --- 6 1 m
Object D5C D5C
Grounded
conductor
3 k max.
R D5C Maintenance
Make sure that the portion of the antenna that comes into contact
with sensing objects is free of oil, dirt, or rust, or any other insulator.
Otherwise, the D5C will not operate.
R: 3 k max. The degree of protection of the D5C is IP67. The D5C cannot be,
The sensing object must not come into contact with the human body however, used in the water or oil.
Non-grounded Object Locations with Sprayed Water or Oil
If the sensing object is the following non-grounded conductor, the The D5C may malfunction in locations where the D5C is frequently
D5C will operate if the capacitance between the sensing object and exposed to sprayed water or oil. Especially, the D5C may
the ground is 30 pF or more. The larger the surface area of the malfunction more frequently if it is exposed to sprayed water-
sensing object is, the higher its capacitance will be. The shorter the soluble cutting oil. In such locations, be sure to take appropriate
distance between the sensing object and the ground is, the higher measures to protect the D5C from oil and water.
the capacitance will be. Furthermore, the capacitance greatly Wiring and Connections
varies with the ground condition (e.g., dry sand, concrete, or wet
soil). Be sure to wire the D5C correctly according to the color of each
cord. Incorrect wiring may damage the internal components of the
Contact with Non-grounded Conductor D5C or the D5C may malfunction.
The sensing object is equivalently grounded through capacitor C.
A maximum of two models can be connected in series provided that
Non-grounded Generally, the conductor will 100 to 240 V is supplied. DC models cannot be connected in series.
conductor be detectable if the ambient
D5C Load
humidity is 60% to 70%RH and
30 pF min.
the surface area of the conductor
100 to 240 VAC
C is approximately 300 500 mm.
D5C
Be sure to supply power to the D5C via the load. If power is supplied
to the D5C directly, the fuse will blow.
C: 30 pF min.
6
D5C
attention so that the leakage current of the D5C AC model will not Antenna
Sensitivity Adjustment
The sensitivity of the D5C can be adjusted by turning the adjuster
on the rear side with a flat-blade screwdriver.
The sensitivity increases by turning the adjuster clockwise (max. 30 pF)
and decreases by turning the adjuster counterclockwise (min. 100 pF).
SENSI
Set point
Grounding
<For DC and AC Models>
In order to maintain the operational reliability of the D5C, be sure to
ground the blue or black wire of the power cable.
(Refer to Output Circuit Diagram on page 4.)
Operation may fail if the D5C is not grounded.
<DC Models>
The service power supply of the PC (Programmable Controller) is
not available to the D5C-1D@0. The negative line of the service
power supply of the PC is not grounded. Therefore, the D5C may
not operate.
Furthermore, if the negative line of the service power supply is
grounded, the noise resistance of the PC will drop.
<AC Models>
Provided that single-phase 200 V is supplied to the D5C-1A@0, if
one phase is grounded, the power supply will be short-circuited and
a machinery breakdown will result. Use an isolating transformer
and ground the secondary side of the transformer instead.
In the above case, be sure to ground the secondary side, otherwise
the D5C may not operate.
Brown
Load
(White)
AC
Blue
D5C (Black)
The lead wire colors of the D5C have been changed in compliance with the
latest applicable JIS standards. Colors in parentheses are previous ones.
7
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRONs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
2012.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.