Magic Tee
This template automatically sets the units to mm and GHz, the background material
to PEC (which is the default) and all boundaries to be perfect electrical conductors.
WCS->Align WCS
WCS->Align WCS
Define Port 1
CST COMPUTER SIMULATION TECHNOLOGY | www.cst.com | Jan-13
Port Definition(II)
Objects->Pick->Pick face Solve->Waveguide port
Define Port 2
Define Port 3
Define Port 4
CST COMPUTER SIMULATION TECHNOLOGY | www.cst.com | Jan-13
Define Units, Set Frequency Range
Solve->units
Solve->frequency
This dialog box gives you the opportunity to define field monitors that you might need to
obtain additional information on the electromagnetic field distribution inside your
structure. It is possible to define frequency as well as time monitors. After a calculation,
you can observe your field monitors by selecting them in the navigation tree.
CST COMPUTER SIMULATION TECHNOLOGY | www.cst.com | Jan-13
Mesh View
Mesh-> Global mesh properties
For the Magic Tee device we are interested in the input reflection at port 1 and in the
transmission from port 1 to the other three ports (2, 3 and 4). Accordingly, we only need
to calculate the S-parameters S1,1, S2,1, S3,1 and S4,1. All of the S-parameters can be
derived by an excitation at port 1. Therefore, you should change the Source type field in
the Stimulation settings frame to Port 1
CST COMPUTER SIMULATION TECHNOLOGY | www.cst.com | Jan-13
Port Signals