Most Critical Interior Panel
Most Critical Interior Panel
Lx = 2.4 m
Top cover mm 25 (Normal weight concrete) Plan
Btm cover mm 25
Edge 4
Edge 2
LOADING characteristic EDGE CONDITIONS
Self weight kN/m 3.60 Edge 1 C C = Continuous
Extra dead kN/m 2.20 Edge 2 C D = Discontinuous Ly = 3.6 m
Total Dead, gk kN/m 5.80 gf= 1.40 Edge 3 C
Imposed, qk kN/m 1.50 gf= 1.60 Edge 4 C 2
Design load, n kN/m 10.52 See Figure 3.8 and clauses 3.5.3.5-6 Edge 3
SUPPORT REACTIONS (kN/m char uno) (See Figure 3.10) Sum vx = 0.889 Table 3.15
EDGE 1 EDGE 2 EDGE 3 EDGE 4 Sum vy = 0.667
1, F-G G, 2-1 2, F-G F, 2-1 equations
v 0.444 0.333 0.444 0.333 19 & 20
Dead kN/m 6.19 4.64 6.19 4.64
Imposed kN/m 1.60 1.20 1.60 1.20
Vs kN/m 11.2 8.4 11.2 8.4
OUTPUT/SUMMARY
SHORT LONG EDGE 1 EDGE 2 EDGE 3 EDGE 4
PROVIDE SPAN SPAN 1, F-G G, 2-1 2, F-G F, 2-1
MAIN STEEL T8 @ 250 B1 T8 @ 250 B2 T8 @ 250 T1 T8 @ 250 T2 T8 @ 250 T1 T8 @ 250 T2