CC Calibration File
CC Calibration File
NO.: G44CPI. EKAMRA VILLA. JAYDEV VIHAR. BHUBANESWAR -751 015 Ph.. 0674 -2558250(0).0674-6523411 (Lab).
Mobile 9937058250 Fax 0674 -2558250, E-mail meher. cal'bral,on@yahoocoln
CALIBRATION CERTIFICATE
WELDING RECTIFIER
Calibration Certificate No. PCL / 514/ 13-14 Issue No : peL / BB / 543 / 13 Date of
ue: 26_04.2013
Date of Calibration CaUbration Pag No of Pages
valid u to e
24.04.2013 23.04.2014 1/1 1
1.NAME & ADDRESS OF CUSTOMER : Mis THERMAX ENGG CONSTRUCTION CO LTD. TATA STEEL PROJECT,
5. CONDITION OF EQUIPMENTS : OK
6. TRACEABILITY : Calibration Is traceable to National Standard thrpugh NABl Accredited laboratory.
7. DETAILS OF THE REFERENCE STANDARD: 1. . DIGITAL CLAMP METER Make : lUTRON, Model: OM6056, Sr. No : 1138471
is traceable to National Standard through NABl Accredited Laboratory, Vide Calibration Certificate no. 5010608, Ot 22.11.2011, Valid upto
21.11.2013.
8 .ENVIRONMENTAL
CONDITIONS : Temperature : 270C :t 20C,
DC VOLTAGE
26_04.2013
Date of Calibration CaUbration valid u to Pag e
24.04.2013 23.04.2014 1/1
1.NAME& ADDRESS OF CUSTOMER : Mis THERMAX
ENGG CONSTRUCTION CO
LTD. TATA STEEL
PROJECT,
KALINGA NAGAR,
JAJPUR.
5. CONDITION OF EQUIPMENTS : OK
6. TRACEABILITY : Calibration Is traceable to National Standard
thrpugh NABl Accredited laboratory.
8 .ENVIRONMENTAL
CONDITIONS : Temperature : 270C :t 20C,
'+ 1.3
50 51.3
'+ 2.5
100 102.5
Temparature
Controller with '+ 3.2
Sensor 50 to 300 oC 150 163.2
'+ 3.5
200 203.5
'+ 4.6
280 284.6
11. Uncertainty measurement at 95"10 of confidence level with coverage factor k = 2 ; +-6.28oC
CALIBRATION CERTIFICATE
HOLDING OVEN
Calibration Certificate No. pel / 553 / 13-14
Issue No : PCl / BB / 5B2 / 13 Date of Issue: 26.04.2013
4 . DETAILS OF INSTRUMENT UNIT UNDER CAUBRAnON (UUC) : DIGITAL TEMPERATURE CONTROLLER WITH SENSOR
MAKE : PERFACT
RANGE : 50to4000e
ID.NO TEE/HO/002
PCL ID.NO. :7680/12-13
RESOLUTION : lOC
5. CONDITION OF EQUIPMENTS : OK
6. TRACEABILITY : Calibration Is traceable to National Standard thrpugh NABl Accredited laboratory.
8 .ENVIRONMENTAL
CONDITIONS : Temperature: 270C: t 20C,
11. Uncertainty measurement at 95"10 of confidence level with coverage factor k = 2 ; +-1.43oC