Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

CDB 4313 HEAT INTEGRATION

CASE STUDIES

ZULFAN ADI PUTRA, PDENG

OFFICE: 05-03-08
TELP: 05 368 7562
EMAIL: [email protected]
Discussion time: Friday 15.00 17.00
COURSE OVERVIEW
Data extraction
Composite Curve
Problem Table Algorithm
Grand Composite Curve
Basics Placement of utilities
Process Modification (+/-)
Heat Exchanger Network Design

HEAT Capital Cost Targeting


INTEGRATION
Retrofitting of
Heat Exchanger Network
Process
integration Reactors and separators

Heat engines and heat pumps


LP/MILP
Automated design
MINLP
2
OTHER EXAMPLE (1)

Temp supply Temp target Heat


o o
C C kW
840 40 4000
70 45 150
50 40 7
24 25 300
30 80 60
25 150 350

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

3
OTHER EXAMPLE (2)

Temp supply Temp target Heat


o o
C C kW
180 181 2500
50 250 300
230 240 600
180 80 100
180 179 293
90 45 180

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

4
OTHER EXAMPLE (3)

Temp supply Temp target Heat


o o
C C kW
180 75 3150
280 120 2400
180 75 3150
50 190 4200
50 250 4000
40 150 1100

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

5
OTHER EXAMPLE (4)

Temp supply Temp target Heat


o o
C C kW
180 55 1250
140 45 2850
220 120 2500
40 230 3800
120 260 4900
40 190 5250

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

6
OTHER EXAMPLE (5)

Temp supply Temp target Heat


o o
C C kW
170 45 3750
180 50 3900
280 90 2850
60 120 1800
40 130 3150
120 210 3150

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

7
OTHER EXAMPLE (6)

Temp supply Temp target Heat


o o
C C kW
160 80 1800
250 100 450
340 90 1350
25 125 950
120 240 2400
150 300 900

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

8
OTHER EXAMPLE (7)

Temp supply Temp target Heat


o o
C C kW
90 50 6200
120 40 4000
105 35 2100
55 65 6000
65 165 18000
10 170 1600

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

9
OTHER EXAMPLE (8)

Temp supply Temp target Heat


o o
C C kW
120 50 5600
120 40 4000
110 90 2000
55 65 3000
80 160 10000
160 170 2000

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

10
OTHER EXAMPLE (9)

Temp supply Temp target Heat


o o
C C kW
200 50 3000
180 100 4000
350 150 2000
60 180 1800
40 100 3000
120 250 2600

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

11
OTHER EXAMPLE (10)

Temp supply Temp target Heat


o o
C C kW
200 201 2000
50 250 300
200 210 600
180 80 1000
180 179 2500
100 50 200

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

12
OTHER EXAMPLE (11)

Temp supply Temp target Heat


o o
C C kW
80 50 6000
130 60 3500
150 40 2700
55 65 8000
80 160 8000
100 170 1400

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

13
OTHER EXAMPLE (12)

Temp supply Temp target Heat


o o
C C kW
800 100 7000
70 30 160
120 40 80
150 151 3000
40 200 3200
25 175 1500

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!

14
OTHER EXAMPLE (13)

Temp supply Temp target Heat


o o
C C kW
300 50 7500
160 40 4000
100 90 2000
55 85 3000
65 185 12000
100 170 1700

With the above data, please do the following:


- Hot and cold composite curve
- Problem table algorithm
- Grand composite curve

Use Tmin of 10, 20, 30, 40, 50 oC!