Brosur New NS Industrial 271014
Brosur New NS Industrial 271014
That means that NS Accelerate powers much more than just your backup
power. from automotive, fleet, heavy duty, marine, renewable energy,
telecommunication and defense: If it needs power, you’ll find NS
Accelerate at the heart of it. although the applications can very greatly
from industry to industry, one thing remains constant; with NS Accelerate
you can be confident that you’ll get reliable power every time.
Capacity Dimension (mm) Maximum
Maximum
Discharge Internal
Voltage Appox. Charge
Model Terminal type Current @5 Resistance
(V) 10HR (Ah) 20HR (Ah) Length Width Height Total Height Weight (kg) Current
Second (mΩ)
(A)
(A)
NSAG 12-40 12 36 40 198 166 171 171 13,3 F4/F11 400 8 8,9
NSAG 12-55 12 49 55 229 138 210 235 18,1 F11/F15 550 11 8,5
NSAG 12-60 12 53 60 260 169 210 235 20,6 F15 600 12 8,4
NSAG 12-65 12 58 65 350 167 180 183 21,2 F5/F11 650 13 8,8
NSAG 12-70 12 62 70 350 167 180 183 22,6 F5/F11 700 14 8,8
NSAG 12-70S 12 62 70 260 169 210 235 21,7 F15/F11 700 14 8,8
NSAG 12-75 12 67 75 260 169 210 235 23,6 F11/F15 750 15 7,9
NSAG 12-80 12 71 80 350 167 180 183 24,2 F5/F11 800 16 7,9
NSAG 12-90 12 80 90 307 169 211 216 28,7 F12/F15 900 18 6,4
NSAG 12-100 12 89 100 328 172 222 222 30,3 F5/F12 1000 20 7,3
FGB 12-100 12 100 110 284 272 210 213 36,2 F10-M8 1000 30 5,0
NSAG 12-120 12 106 120 407 177 225 225 35,3 F5/F12 1200 24 5,4
NSAG 12-134 12 119 134 340 173 280 285 41,6 F5/F12 1340 26,8 5,0
NSAG 12-145 12 129 145 340 173 280 285 44,3 F5/F12 1450 29 5,0
NSAG 12-150 12 133 150 483 170 240 240 44,6 F5/F12 1500 30 5,9
NSAG 12-160 12 142 160 530 209 214 219 50,3 F12/F16 1600 32 5,9
NSAG 12-180 12 160 180 530 209 214 219 53,2 F12/F16 1800 36 5,4
NSAG 12-200 12 177 200 522 240 219 240 60,3 F16 2000 40 5,1
NSAG 12-225 12 200 225 522 240 219 240 65,2 F16 2250 45 4,6
NSAG 12-230 12 204 230 521 269 203 208 67,1 F12 2300 46 5,9
NSAG 12-260 12 231 260 521 269 203 224 74,2 F14 2600 52 4,8
Dimension (mm)
Voltage Capacity Appox. Internal
Model Terminal type
(V) 10HR (Ah) Total Weight (kg) Resistance (mΩ)
Length Width Height
Height
OPzV 2-200 2 200 103 206 355 397 18,3 F10-M8 0,78
OPzV 2-250 2 250 124 206 355 397 22,2 F10-M8 0,56
OPzV 2-300 2 300 145 206 355 397 25,1 F10-M8 0,55
OPzV 2-350 2 350 124 206 471 513 29,2 F10-M8 0,40
OPzV 2-420 2 420 145 206 471 513 33,4 F10-M8 0,35
OPzV 2-500 2 500 166 206 471 513 39,0 F10-M8 0,35
OPzV 2-600 2 600 145 206 646 687 48,4 F10-M8 0,30
OPzV 2-800 2 800 191 210 646 687 64,5 F10-M8 0,30
OPzV 2-1000 2 1000 233 210 646 687 75,0 F10-M8 0,25
OPzV 2-1200 2 1200 275 210 646 687 90,2 F10-M8 0,23
OPzV 2-1500 2 1500 275 210 795 836 110,5 F10-M8 0,22
OPzV 2-2000 2 2000 399 214 772 813 150,6 F10-M8 0,21
OPzV 2-2500 2 2500 487 212 772 813 190,3 F10-M8 0,18
OPzV 2-3000 2 3000 576 212 772 813 220,4 F10-M8 0,18