ATyS Catalogue
ATyS Catalogue
COIMBATORE VIJAYAWADA
Designer Complex, LUCKNOW D.No.-29-37-135, 2nd Floor,
Door No.130, C/2, 2nd Floor, The Business Bridge, Ist Floor, G. R. Plaza, Beside Canara Bank,
Dr. Nanjappa Road, Saran Chamber IInd, 5 Park Road, Eluru Road, Vijayawada-520 002
Coimbatore - 641018 Lucknow - 226001 Ph.: 0866- 2442275, 6622291
Ph.: 0422-4393995 Ph.: 0522-4021687 E-mail : [email protected]
E-mail : [email protected] E-Mail: [email protected]
VIZAG
DEHRADUN B.K. Towers, 49-34-1/63,
E-13D Business Centre LUDHIANA Akkayyapalem Main Road,
49, Raipur Road, Dehradun (Uttrakhand) 5 - A , First Floor, Roshan Market NH-5 Junction, Vizag-530 016 (A.P.)
Ph.: 0135-2650340, 2650373 Vishwakarma Chowk, Ludhiana Ph.: 0891-2794506, 6461730
E-mail: [email protected] E-Mail : [email protected] E-mail : [email protected]
1/21, Asaf Ali Road, New Delhi - 110002 Ph.: 23234411 Fax : 011-23232639 www.socomec.com
e-mail:[email protected], [email protected]
Presentation CONTENTS
Founded in 1956, HPL is regarded as the “Technology brand in India” and is one of the premium
manufacturers of reliable Electrical Protection Equipments, Switchgears Energy meters and Energy
Management Systems, and has a strong work force of over 3200 talented individuals, including
Technocrats, Design and R&D Engineers and Marketing Professionals.
The collaboration between SOCOMEC and HPL is now almost 16 years old. The association has been
beneficial to both partners by way of market study, evaluation, new product developments and even
SWITCHING
quality component sourcing.
Now SOCOMEC HPL is proud to introduce its latest development in Changeover Transfer Switches,
produced in the factory in Gurgaon. A newly designed range of Automatic Transfer Switches (ATS)
CONTROL
branded ATyS, from 63A to 3200A
AND
PROTECTION
MOUNTING AND CABLING
SYSTEMS
Backed up by significant research and development
resources, our offer is constantly evolving to meet
the changing needs of our clients.
For more than 85 years, our partner-clients have recognised
the quality of our products, our attentiveness to their needs,
our adaptability and our commitment.
SOCOMEC is an independent group. Its international
ACTIVITÉ
dimension gives it the ability to rise to the challenge
wherenever you need it to. SYSTÈMES D’ALIMENTATION
SANS INTERRUPTION
1 SOCOMEC-HPL Automatic Transfer Switch CATALOGUE 2
Services SERVICES
A high-tech organisation Adapted provision of services
at your service
> The company on your > Constant innovation > The right products > Pierre SIAT electrical test station
doorstep Since 1965, the SOCOMEC production Our team of dedicated professionals will
Technological scanning is second nature We offer you the most comprehensive
We attach great importance to supplying for our people. Working hand-in-hand with range of switching and protection systems site has also included a test facility. assist you in carrying out tests for
you with the best product to suit your numerous technological partners means available on the market: thanks to This laboratory is a member of ASEFA compliance with French, European or
requirements. That’s why we have a fully we can continually build on our expertise. ‘customised’ solutions adapted from (the French Association of Electrical world standards.
integrated sales network that really And with substantial R&D resources behind standard products, our range is able to Appliance Test Facilities) and is accredited Types of tests performed: dielectric tests,
understands your industrial environment. us we are able to offer the right product to cover a wide spectrum of applications. by COFRAC, the French accreditation heat tests, mechanical endurance tests,
Relevant departments work closely with satisfy your every need. Concentrating on modular design and a committee. system tests, climatic tests, short-circuit
you, depending on the project. Our innovations benefit your performance. full range of easy-to-mount accessories Now you can benefit from SOCOMEC's tests.
With SOCOMEC-HPL, our specialists also means that you benefit from many substantial expertise by having your own
are always close to hand should you complementary and cost-effective tests conducted within this specialist
need them. functions. facility.
SITE 041 A
SITE 118 A
SITE 117 A
> Delivering on time > Integrated production with > Customer satisfaction
shorter lead-times
Real-time order and logistics management Product quality is assured in our own
is our guarantee of a prompt and efficient As an independent manufacturer, ASEFA (French Association of Certified
delivery service. SOCOMEC-HPL exercises complete Testing Stations) and LOVAG (Low Voltage
Count on us to get your product to you control over its strategic design and Agreement Group) - certified testing
CORPO 163 A
on time, everytime. manufacturing processes and makes laboratory. Numerous agreements and
full use of the latest advances as far certifications (not forgetting a proven and
> Friendly and direct contact as flexibility is concerned. Our tested quality assurance) ensure that our
Being an independent manufacturer integrated production organised in equipment fully complies with international
also lends SOCOMEC-HPL its own autonomous working groups offers standards: KEMA, CEBEC, UL, CSA,
ASTA, Lloyd’s Register of Shipping, Bureau
> Metrology
special ‘style’: Doing business with us customers guaranteed manufacturing
means being in contact with friendly and quality with full control over delivery Véritas, BBJ-SEP, EZU, GOST-R… Can you guarantee the quality of the
responsible people; committed people times. Universal and adapted solutions, whatever measurements that you take during the
who care about giving the right solution your configuration - our expertise assures development, production or testing of
to meet your requirements. your complete satisfaction. your products?
SOCOMEC provides you with its
metrological know-how to inspect and
certify your measuring tools.
CORPO 175 A
CORPO 024 A
APPLI 079 A
3 SOCOMEC-HPL Automatic Transfer Switch CATALOGUE 4
SAT
> Manufacturer’s expertise > Optimum service guaranteed > A team of "field" specialists
Over several decades, SOCOMEC’s Supply transfer in complete Effective insulation monitoring of your Specially adapted skills Reassuringly close at hand Constantly attentive to your needs
Switching and Protection Systems have safety electrical installation Our intervention team consists of field Our geographical coverage means that True to our own principles, we encourage
acquired a distinguished reputation in the Changeover switches are strategic To ensure that your insulation fault personnel specialising in our specific we are close to each user and can direct and friendly contact.
domain of low voltage electrical distribution components that ensure continuity of monitoring and location system operates to domains and experienced in the respond quickly to all requests, providing Our interventions are targeted solutions
equipment testing and safety. service of supplies. In order to guarantee its optimum capacity, our team of maintenance of industrial electrical a complete service from the technical to a single problem: yours. Our engineers
Our manufacturer’s expertise naturally complete operational safety, we will specialists perform all operations on site. systems. You therefore benefit from a diagnostics before repair right up to are always very attentive to ensure that
extends to a complete offer of services implement our range of innovative supply This means that you benefit from renowned dual competence: technical expertise implementation of the most suitable we provide you with the most relevant
designed to help you get the most out of transfer solutions. expertise, as well as solutions tailored to the adapted to the products used and a solutions for your installation. technical support and advice. There's no
your installation. Your energy consumption specific monitoring requirements of your practical knowledge of your specific need to worry about your investments…
comprehensively managed electrical installation. needs.
Monitoring of energy consumption within Cost-effective electrical
any installation is one of your primary usage
operational considerations. To this end, The presence of a specialist enables you
our consultant engineers will make use to reduce your reactive energy costs, limit
of SOCOMEC’s range of market leading your energy losses by Joule effect, cut
energy measurement metering and end of line voltage drops or increase your
management systems. available active power… A real return on
investment.
Picture
CORPO 164 A
CORPO 155 A
> Tailor-made features
Commissioning Training
Installation of your equipment is carried out You will receive training, specially adapted
by a specialist, and is totally compatible to your needs, in order to familiarise you
with and adapted to your use. with our equipment and enable you to
use it to your best advantage.
Tailor-made features
A broad range of features tailored to Maintenance contracts
respond to the particular requirements and A wide range of preventive or corrective
limitations of your electrical installation, and maintenance options designed to suit
to help you deal with specific operational your installation and its environment, and
demands. to ensure continuity of service of your
electrical networks.
CORPO 174 A
APPLI 080 A
Do not hesitate to contact our SOCOMEC-HPL sales office to discuss a service
package tailored to your requirements.
ATyS 63 to 3200 A
APPLICATIONS
CHARACTERISTICS
18/29
PAGES 9 9 9 19 19 19 19 57
atysm_029_b
> ATyS M 6s: simple and ergonomic
Configurable automatic transfer switch cycles, with stable positions.
atysm_031_b
IS : 13947
atysm_030_b
A PRODUCT FOR ALL CHANGEOVER APPLICATIONS FROM 63 TO 160 A
> Network/Generator Set > Network/Network
• Generator set control • ATS solution • Building services • Control with or without priority
M 3s M 6s M 6e
GS M 6e GS
M 6s
atysm_003_a_gb
atysm_004_a_gb
atysm_005_a_gb
atysm_006_a_gb
Non-critical Non-critical Non-critical
U
U
U
P
P
P
loads loads M 6e loads
S
S
S
Critical Critical Critical
loads loads loads
atysm_019_a
atysm_021_a
• Stable positions
atysm_038_a
> A new switching module combining
• High dynamic withstand
> Auxiliary contacts > Terminal shrouds
• Fast operation
• High number of operations
atysm_027_a
atysm_035_a
> Two power switches
taysm_002_a
atysm_033_a_1_cat
Enables fast I - II switching operation
atys_565_c
> An available energy storage
device
atysm_037_a
FLEXIBLE INTEGRATION
atysm_016_b_1_cat
atys_028_c_gb
appli_177_a
appli_179_b
Operation
ATyS M 6s ATyS M 6e
atysm_031_b
atysm_030_b
4 potentiometers Display + Keypad
• Nominal voltage configuration. • Parameters configuration (thresholds, timers …).
• Voltage and frequency thresholds configuration. • 3 phases voltage and frequency for source I and II, timers,
• Operating cycles timers configuration: MFT (0 to 60s), DTT (5s), number of cycles and last event display.
MRT (0 to 30 min), CDT (4 min). • Tests and positions control facilities.
4 dip switches Leds
50 or 60 Hz, single or three phases, 2 seconds 0 position Power On; Sources availability; Changeover position;
transition during I-II transfer cycles (0MR/0MF), Network / Network “MAN / AUT” mode; Test / Control operation; Fault.
or Network / Genset application. 3 configurable inputs
4 leds Automatic mode inhibition; Test on load and off load; Manual
Power supply sources availability; Automatic mode (cover retransfer; Changeover position control; Network priority change.
opened); Fault (command order and position not reached). 1 NO bi-stable output relay for generator start /stop command
3 external command inputs (30 VDC / 2 A).
• Automatic mode inhibition.
• Remote test on load (or priority change). 2 programmable output relays (250 VAC / 3 A)
• Manual retransfer from emergency source to main source Source I or II availability; Load shedding output; Fault relay.
(validation required).
• Control 0 position if both supplies are available (1+2+3) at the ATyS D10 or D20 remote interface connection.
same time.
1 NO bi-stable output relay for generator start /stop command
(30 VDC / 2 A).
1 NO fault relay (250 VAC/ 0.5 A).
References
ATyS M - Accessories
ATyS M
3 3
Bridging bars
atysm_013_a_2_cat
Use References
atysm_025_a_1_cat
atysm_026_a_1_cat
atysm_027_a_1_cat
atysm_028_a_1_cat
atys_612_a_1_cat
To provide common point on Rating (A) No. of poles References
atysm_025_a_1_cat
either incoming or outgoing 63 … 125 4P 13094006G
terminals.
160 4P 13094016G
Voltage sensing DPS -
Rating No. ATySM Bridging and power Terminal Auxiliary Double power
(A) of poles 3s (1) bars supply tap shrouds(2) contacts(3) supply
63 4P 13234006G
Voltage sensing and power supply tap
80 4P 13234008G 1 AC st
Use Reference
13094006G pair pair standard
100 4P 13234010G Allows up to 2 x <=1.5 mm 2 Rating (A) No. of parts Reference
15994001G
13994006G 22944016G 2nd AC voltage sensing or power cables
atysm_026_a_1_cat
63 … 160 Pair 13994006G(1)
125 4P 13234012G 13090001G connection. To be mounted in
any terminal cage when bridging (1) 2 parts per reference.
160 4P 13234016G 13094016G bar not used.
atysm_027_a_1_cat
Advantages (1) To shroud front changeover top and bottom 2 references required.
atysm_007_a_2_cat
atysm_026_a_1_cat
atysm_027_a_1_cat
atysm_028_a_1_cat
atys_565_c_2_cat
thermographic inspection
atysm_043_a
without dismantling.
Rating Network
Voltage sensing Auxiliary contacts
No. ATySM ATySM Bridging and power Terminal Auxiliary Remote Sealable
(A) of poles (VAC) 6s 6e bars supply tap shrouds(1) contacts(2) interface(3) cover(4) Use Reference
Up to 2 auxiliary contacts For ATySM 3s
63 4P 127 / 230 13534006G 13634006G accessory per product.
Rating (A) Reference
Each accessory integrates 3
atysm_028_a_1_cat
4P 230 / 400 13544006G 13644006G 63 … 160 standard
NOC auxiliary contacts, one per
80 4P 127 / 230 13534008G 13634008G position I, 0, II. 1st AC - 2
nd
AC 13090001G
Characteristics: 250 VAC / 5 A
4P 230 / 400 13544008G 13644008G ATyS D10 maximum. For ATySM 6sand 6e
13094006G 15992010G
100 4P 127 / 230 13534010G 13634010G Rating (A) Reference
pair pair 63 … 160 13090001G
4P 230 / 400 13544010G 13644010G 13994006G 22944016G 13090001G 15590000G
ATyS D20
125 4P 127 / 230 13534012G 13634012G 15992020G
Sealable cover
4P 230 / 400 13544012G 13644012G Reference
Use
160 4P 127 / 230 13534016G 13634016G Controls settings cover to Rating (A) Reference
13094016G prevent ATyS M 6s parameters 63 … 160 15590000G
4P 230 / 400 13544016G 13644016G access due to a sealable facility.
atysm_043_a
atysm_008_a_1_cat
52 104 176
47
116
26
Thermal current I th (40°C) 63 A 80 A 100 A 125 A 160 A
Rated insulation voltage U i (V) (power circuit) 800 800 800 800 800
131,5
245
350
143
45
1
Rated impulse withstand voltage U imp (kV) (power circuit) 6 6 6 6 6
Rated insulation voltage
i U (V) (operation circuit) 300 300 300 300 300
atysm_034_a_1_x_cat
Rated impulse withstand voltage U imp (kV) (operation circuit) 4 4 4 4 4 18
6 x M6
Supply 230 VAC min / max (VAC) 176/288 176/288 176/288 176/288 176/288
ATyS M 6s
Control supply power demand RJ RS 1: manual retransfer / priority change (1)
A 2: test on load (1)
Max current under 230 VAC (A) 30 30 30 30 30 3: automatic mode inhibition (1)
6: fault relay and front cover open
Nominal power (VA) 6 6 6 6 6 7: genset start / stop relay
Mechanical characteristics B (1) 1+2+3: control 0 position.
Endurance (number of operating cycles) 10 000 10 000 10 000 10 000 10 000
ATyS M 6e
Weight switch (kg) 3.5 3.5 3.5 3.5 3.5
atysm_041_d_1_x_cat
1 - 2 - 3: programmable input
(1) A/B: Category with index A = frequent operation / Category with index B = infrequent operation. 6 7 4 5 6 7 4: “non automatic” mode output
(2) With terminal shrouds or phase barrier. 207 208 209 210 63 64 73 74 207 208 209 210 43 44 53 54 63 64 73 74 5 - 6: programmable output
(3) For a rated operating voltage Ue = 400 VAC. 7: genset start / stop relay
1 3 1 3
(4) Between the order given and the arrival in position (under the nominal conditions). 2 2 8: RJ 45 ATyS D10/D20 remote interface connection
1 2 9: RS485
A : bridging bar (accessory)
ATyS M 6s ATyS M 6e B : auxiliary contacts (accessory) - 1 AC per position I, 0, II
ATYS 015 C
ATYS 298 A
switches(ATyS 6). > Load bridging made easy by using
They are a combination of two load-break the bridging bars available as
switches mounted back to back accessories
electrically and mechanically interlocked.
FLEXIBLE UPGRADEABILITY
atys_003_a_1_cat
ATYS 011 A
ATYS 016 C
ATYS 289 A
ATYS 564 C
atys_102_a_1_cat
General characteristics
ATYS 565 C
Programming software Optional modules
• Isolation with positive break indication.
• On load switching.
> A double power supply module
• Manual emergency operation. ATyS D10 / D20 remote interface
• 3 stable positions (I, 0, II) or overlapping The DPS module allows the ATyS 3s to be powered from the available with RJ45 connection
source (Normal / Emergency). • Bridging bars, terminal shrouds,
contacts on request (I, I+II, II), for ATyS only.
terminal screens, optional
• Padlocking in 0 or in all three positions
(I, 0, II). padlocking in 3 positions,
• AUTO / MANU selector. special locks, additional
auxiliary contacts…
ATYS 597 A
ATyS from 125 to 3200 A
Rear view
10
DPS
ATYS 596 B
7
9 1. Backup handle and support ATyS 3s
(included with device)
2. Handle key interlocking accessories
8 6 SECURE SWITCHING FOR ALL YOUR APPLICATIONS
3. Door protective surround
11 4. Additional auxiliary contacts
4
5. Standard device > Network / Generator set permutation > Network / Network permutation
6. Connecting cable for ATyS D10 or D20
5 remote interfaces (ATyS 6)
7. ATyS D10 or D20 interfaces
12 3 (ATyS 6)
8. Plug-in optional modules
(not for ATyS 3s)
9. Voltage sensing and power supply kit
4
GE
4
3
2
3
2 (ATyS 6)
1
1
10. Terminal shrouds
ATYS 285 C GB
11. Bridging bars
ATYS 284 C
9 12. Mounting spacers
13. Terminal screens
atys_615_a_1_x_cat
1
13 Non-critical
loads
Critical
loads UPS
coff_306_a_2_cat
operation and allows handle use when features:
positioned in manual mode. This selector
atys_097_b_1_cat
Features
• Compact design.
Backup manual operation • Mechanically interlocked switching.
The product can still be switched without
any power source using the manual
operation. The handle (supplied with the
atys_013_a_1_cat
Main accessories
Remote control interface
Enables operation, configuration and display
of all the functions remotely. It can be
atys_565_c_2_cat
atys_712_a
Padlocking • Specific cable entry requirements available upon request.
Up to three padlocks can be used to lock • Neutral position located on the right as standard.
the device. • Alternative options available upon request.
When padlocked:
- manual operation is not possible, Main accessories
- electrical controls are disabled. • Double (Self) power supply for ATyS 3 only.
atys_008_a_1_cat
svrmo_077_c_1_gb_cat
(45-65 Hz), one defined as power source 1 and the other as priority power source 1 Single or three phases control on networks I and II
backup power source 2 . Electrical operation of the product is stand by power source 2
• Independent Under/ Over voltage and Under / Over frequency
possible as soon as one of the power supplies is available. thresholds: +/- 20% of nominal value.
switching operation possibility • Adjustable hysteresis thresholds.
Control logic • Phase rotation control.
General
• The switching operation can be driven by an external dry contact. “Pulsed contact logic” (impulse) or “maintained contact log ic” Operation
(contactor), are both recognised on the control inputs.
• The type of logic must be selected during configuration (programming).
• Priorities: the first order received has priority as long as it is present. A zero command has always priority, excepted in c ase of controls
inhibition.
• ATyS 3e integrates number of operation counter and allows optional communication or inputs/outputs module connection.
atys_679_a_1_x_cat
Impulse logic Contactor logic
• The switching command is a pulsed dry contact lasting at least • The transfer command is a maintained dry contact.
100 ms. • If command I or II disappears, the device returns to zero
• When the order disappears, the product remains in position.The position, if power supply is available.
impulse can be of infinite duration without causing any • A 0 command drives the device into zero position, irrespective of
disturbance. the status of the I and II commands.
orderI orderI
orderO orderO
order II order II
svrmo_079_b_1_gb_cat
atys_024_a_1_gb_cat
positionI positionI
positionO positionO
positionII positionII
SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify features A Display + keypad 1 configurable generator set bi-stable start/stop relay
without prior notice in view of continued improvement. 2008 - 2009
• Setup and Thresholds configuration. (30 VDC, 5 A, AC1).
• Timers configuration MFT (0-60 s), DTT (0-60 s), 0MF (0-20 s), 1 NO fault relay activated in case of changeover position
MRT (0-60 min.), 0MR (0-20 s), CDT (0- 10 min.). ordered and not reached (30 VDC, 5 A, AC1).
Operating principle • Voltage, Frequency, Timers monitoring.
• Test and positions control operations. Control modes
• Test on-load (load transfer): allows loss of main’s network
Automatic mode (AUT) simulation. The complete automatic cycle is then followed.
Leds
Power on; Fault; Sources availability; Changeover position; Can be activated from the keypad of the device or remotely from
AUT mode; Test and control modes of operation. an external dry contact.
Generator stop • Test off-load (without load transfer)a: llows a generator set start
Source 1 failure and stop operation.
MFT Metering Can be activated from the keypad of the device.
CDT • Control I, 0, II:allows the product to be driven into one of the
Normal / Emergency Timers • 3U on network 1 and 2.
positions ; the automatic cycle is then no longer active.
Generator start Switch to position 1 • Frequency on network 1 and 2 .
• MFT: source 1 failure timer (0 to 60 s) Can be activated from the keypad of the device’s front or using
• Normal/Emergency timers. and external dry contact.
• DTT: delay to transfer on source 2 (only for genset) set timer
• 3I, In, P, Q, S, PF (3 phases) on ATyS 6m.
atys_028_d_1_gb_cat
ATyS 3s
ATyS 3e
G
G
G
G
G
G G
G G
On request G
On request G
On request G
G
G
G
G G
G G
G G
G G
G G
G G
G G
G G
G
G G
G G
G G
G G
G
1 No.NC As standard
(1)
G
G
G
G
G
G
G
G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G G
G
G
G G
G
G
G
G
G
Dimensions
Functions Shaft
The BY-PASS ATS are used to isolate an interlocked extensions
electrical equipment type ATS (Automatic No. of Switch Direct external for external Bridging Auxiliary Terminal Terminal
Transfer Switch) without interruption of the Rating (A) poles body only handle handle handle bars contacts (1) shrouds (2)(3) screens (4)
load's supply.
The BY-PASS ATS SOCOMEC HPL ensures
isolation simultaneously upstream and 125 A 12 + 4 P 4100 9813
downstream. 1P
The installation contains a SOCOMEC' 4109 0019
4P 4P
changeover switch, which allows to select the 160 A 12 + 4 P 4100 9816 200 mm 2694 4014(1)(2) 1509 4012 (3)
source during by-pass. 1401 1520
S3 S3
1er / 2 e
Black IP65 Black IP65 320 mm 1P
250 A 12 + 4 P 4100 9825 contact
I - O - II I - O - II 1401 1532 4109 0025 NO/NC
1433 3113 1433 3113 4109 0021
400 mm
Characteristics 400 A 12 + 4 P 4100 9840 1401 1540 1P
4109 0039
4P 4P
2694 4021(1)(2) 1509 4025 (3)
?
From 125 to 1600A
?
Only 4-poles type available
?
Manual operation 1P 4P 4P
630 A 12 + 4 P 4100 9863
?
3 stable positions (I,0,II), and change-over 4109 0063 2694 4051(1)(2) 1509 4063(3)
on load (AC-22)
?
Fully visible breaking
?
Mechanical interlock 800 A 12 + 4 P 4100 9880
?
IP20 product and accessories 1P
?
Direct and external operation 4109 0080
1000 A 12 + 4 P 4100 9881
Black Black IP65
4P
I - 0 - II genuine consult us
2799 7062 1509 4080 (3)
2797 7147(4)
Accessories 1250 A 12 + 4 P 4100 9882
?
Bridging bars 1P
4109 0160
?
Auxiliary contact
?
Terminal screens 1600 A 12 + 4 P 4100 9886
?
Terminal shrouds
(1) To fully shroud front, rear, top and bottom 8 references are required.
?
Padlocking (2) To shroud front switch top and bottom 4 references are required
?
Other accessories available (3) Top/Bottom
(4) Shaft extensions for external handle included
acces_001_a_1_x_cat
acces_132_a_1_x_cat
supply T1 for example) 125 ... 630 direct 1 4109 1006 (1)
125 ... 630 external 3 1499 7701
With SIRCOVER : The choice of the source, 800 ... 1600 direct and external 2 consult us
which will supply the load during the BY-PASS, (1) Specific Handle included
is possible.
Locking using RONIS EL11AP lock in position I, 0, II (not included)
Rating (A) Operation Figure Reference
125 ... 630 direct 1 41091002 (1)
acces_158_a_1_x_cat 800 ... 1600 direct 2 consult us
(1) Specific Handle included
CA
Thermal Current Ith (40°C) 125 A 160 A 250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A
V
Rated Insulation Voltage Ui (V) 800 800 800 800 1000 1000 1000 1000 1000
AA
BA
N
Rated impulse withstand Voltage Uimp (kV) 8 8 8 8 12 12 12 12 12
210
CA
Rated Operation currents Ie (A) H
Rated Voltage Load duty category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
X T T T T T T X
400VAC AC-21 A/AC-21 B 125/125 160/160 250/250 400/400 630/630 800/800 1000/1000 1250/1250 1600/1600 61
400VAC AC-22 A/AC-22 B 125/125 160/160 250/250 400/400 630/630 800/800 1000/1000 1250/1250 1600/1600 J J1
400VAC AC-23 A/AC-23 B 125/125 160/160 250/250 250/250 500/500 800/800 1000/1000 1250/1250 1250/1250
690VAC (2) AC-20 A/AC-20 B 125/125 160/160 250/250 400/400 630/630 800/800 1000/1000 1250/1250 1600/1600 External front operation
690VAC (2) AC-21 A/AC-21 B 125/125 160/160 200/250 200/250 500/500 800/800 800/800 800/800 1000/1000
A
690VAC (2) AC-22 A/AC-22 B 125/125 125/125 125/160 125/160 315/315 800/800 800/800 800/800 1000/1000
690VAC (2) AC-23 A/AC-23 B 63/80 63/80 100/125 100/125 160/200 200/250 200/250 200/250 500/500
125
220VDC DC-20 A/AC-20 B 125/125 160/160 250/250 400/400 630/630 800/800 1000/1000 1250/1250 1600/1600 C
220VDC DC-21 A/AC-21 B 125/125 160/160 250/250 250/250 630/630 800/800 1000/1000 1250/1250 1250/1250 45
220VDC DC-22 A/AC-22 B 125/125 160/160 250/250 250/250 500/500 800/800 1000/1000 1250/1250 1250/1250 B
220VDC DC-23 A/AC-23 B 125/125 125/125 200/200 200/200 500/500 800/800 1000/1000 1250/1250 1250/1250
440VDC DC-20 A/AC-20 B 125/125 160/160 250/250 400/400 630/630 800/800 1000(4)/1000(4) 1250/1250 1600/1600
210
440VDC DC-21 A/AC-21 B 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 500(3)/500(3) 800(4)/800(4) 1000(4)/1000(4) 1250(4)/1250(4) 1250(4)/1250(4) A. Handle S2 type for external front operation : 125 to 160A
H 25
440VDC DC-22 A/AC-22 B 125(3)/125(3) 125(3)/125(3) 200(3)/200(3) 200(3)/200(3) 500(3)/500(3) 800(4)/800(4) 1000(4)/1000(4) 1250(4)/1250(4) 1250(4)/1250(4) E min. B. Handle S3 type foir external front operation : 250 to 630A
440VDC DC-23 A/AC-23 B 125(4)/125(4) 125(4)/125(4) 200(4)/200(4) 200(4)/200(4) 500(4)/500(4) 800(4)/800(4) 1000(4)/1000(4) 1250(4)/1250(4) 1250(4)/1250(4) 1 61 C. Door drilling for front operation
Operation Power in AC-23 (kW) (1) (4) 1. Minimal length with shaft extension : E min + 50 mm
At 400 VAC without pre-break AC 63/63 80/80 132/132 132/132 280/280 450/450 560/560 560/560 710/710
Overall dimensions Switch body Switch mounting Connection terminals
At 690 VAC without pre-break AC 55/75 55/75 90/110 90/110 150/185 185/220 185/220 185/220 475/475 Calibre (A) A 8p. E min H J 8p. J1 8p. M 8p . N T U V W X 8p. Y Z Z1 AA BA CA
125 610 260±1 193 238 338 576 101 36 20 25 8,5 76 3,5 47 143 135 115 10
Reactive Power (kvar (4) 160 610 260±1 193 238 338 576 101 36 20 25 8,5 76 3,5 47 143 135 115 10
At 400 VAC 55 75 115 185 290 365 575 575 250 725 260±1 193 295 396 691 116 50 25 30 11 83,5 3,5 49 143 160 130 10
400 725 260±1 193 295 396 691 116 50 35 35 11 83,5 3,5 49 143 170 140 15
Fuse Protected short-circuit withstand (kA rms prospective) (5) 630 850 337±1 270 358 458 816 176 65 45 50 13 91,5 5 62 199 235 220 20
Prospective short-circuit current (kA rms) 100 100 50 18 70 50 100 100 100
Associated fuse rating (A) 125 160 250 400 630 800 1000 1250 2 x 800
Overload Capacity
324
Rated short-time withstand current 1 s.Icw (kA rms) 7 7 9 9 13 26 35 3550 A
= = Z
Connection Y
CA
90
Minimum Cu Cable section (mm2) 35 50 95 185 2x150 2x185 2x240
V
Minimum Cu busbar section (mm2) 2x30x5 2x40x5 2x50x5 2x60x52x80x5
Maximum Cu Cable section (mm2) 50 95 150 240 2x300 2x300 4x185 4x185 6x185
250
AA
BA
380
Maximum Cu busbar section (mm2 25 25 32 32 50 63 63 63100
Min. tightening torque (Nm) 9 9 20 20 20 20 40
Mechanical Characteristics
CA
Y
X T T T J1 T T T X 19
Endurance (number of operating cycles) (7) 10 000 10 000 10 000 10 000 5 000 3 000 3 000 3 000 4 000 J J 344
545
(7) Increased endurances : please consult us.
M
Connection Terminals ø12,5
BY-PASS ATS 1250 to 1600 A
Overall
12,5
800 1 055 510,5 189 1 021 80 60,5 81,5 7 84,5 321 268 26,5
ø 15
svr_098_a_1_x_cat
25 25 1000 1 055 510,5 189 1 021 80 60,5 81,5 7 84,5 321 268 26,5
30 30 1250 1 320 643 195 1 286 120 44 88 8 85,5 288 258 15
8.5 33 8.5 45 45 1600 1 320 643 195 1 286 120 44 88 8 85,5 288 258 15
90
50
ø9
atys_712_a_1_cat
Single Double
Standard device - 230 VAC line line
Functions Rating (A) No. of poles References References
G • ATyS 6m Automatic Transfer Switch provides all functions 63 4P 17734007G 17744007G
G required for break before make ATS applications.
100 4P 17734011G 17744011G
G • The SOCOMEC BY-PASS system allows complete ATS isolation.
Top and bottom isolation is achieved using the SOCOMEC 125 4P 17734013G 17744013G
G
12+4 pole BY-PASS switch up to 630 A. 160 4P 17734016G 17744016G
G
• For the double line version during the ATS isolation, supply, 250 4P 17734025G 17744025G
G
selection remains possible thanks to a manual changeover. 400 4P 17734040G 17744040G
G
• ATyS 6m associated to a ATyS D20 remote display allows 630 4P 17734063G 17744063G
G
configuration, operation and measurement from outside the panel 800 4P 17734080G 17744080G
G (adjustable time/transfer delays and control level (U, F), generator
1000 4P 17734100G 17744100G
G start/stop control,...).
G
1250 4P 17734120G 17744120G
• Different optional accessories are available.
1600 4P 17734160G 17744160G
207.6
• Floor standing feet from 630 to 1600 A rating. N SIRCOVER
Q2
• Terminals protection screen. SIRCOVER BY-PASS
ATS 12 + 4
• Steel enclosure.
atys_717_a_1_gb_cat
atys_718_a_1_gb_cat
Q1
• RAL 7035.
1-2 2-2 1-2
Q3
By-pass ATS
Cable entry
Up to 400 A
• Bottom cable entry as standard. From to 630 A
LOAD Earth connection rand plate
• Specific cable entry requirements available upon request. Cu 15 x 3
• Neutral position located on the right as standard. Example: ATyS 6m 400 A - double line version with isolation BY-PASS in
• Alternative options available upon request. enclosure.
For the double line version, I4 or II2 closed depending on supply source required.
H
1
atys_708_a_1_gb_cat
ATyS from 125 to 630 A - SINGLE LINE ATyS from 125 to 630 A - DOUBLE LINE
T1 T2 T1 T2 2
1. Remote interface ATyS D20
12.5
3
2. Up to 400 A
S2
3. From 630 A
S1
atys_714_a_1_gb_cat
I3
BY-PA SS ATS
II I3
BY-PA SS ATS
II 250 120 150 1200 800 400 848 1158
400 240 240 1200 800 400 848 1158
D
Load Load
Floor standing - Bottom
• 1 ATyS 6m • 1 ATyS 6m Connection
• 1 SIRCOVER 12 + 4 pole • 1 SIRCOVER 12 + 4 pole Rating (A) section (mm 2) Max. connection section (mm 2) H W D M N
• 1 SIRCOVER 4 pole 630 300 300 1600 1000 400 - -
800 2 x 185 2 x 300 2200 1000 1000 - -
1000 2 x 240 2 x 400 2200 1000 1000 - -
ATyS from 800 to 1600 A - SINGLE LINE ATyS from 800 to 1600 A - DOUBLE LINE 1250 - 4 x 185 2200 1000 1000 - -
1600 - 4 x 400 2200 1000 1000 - -
T1 T2 T1 T2
I3 II I3 II
Steel enclosure
Environment
The complete enclosure meets the following environmental requirements:
- operating temperature: -10 to +40 °C without de-rating, - 95 % humidity non condensing at +40 °C,
- operating temperature: +40 to +65 °C with de-rating, - maximum operating altitude without switch de-rating is 2000 m
- maximum storage is one year, above sea level.
- 80 % humidity non condensing at +55 °C,
Functional diagram
Load
3 1 2
C C 18
6 4 5
19
9 7 8
20
A A
12 10 11
21
B B
2 1
Manual changeover
A
1 Power 230 VAC
Power 230 VAC 2
ATyS
6m
Isolation
103
N
BY-PA SS
203
L1
Voltage sensing
Voltage sensing
L3
104
L2
17
SIRCOVER 8p (from 800A to 1600A)
L2
B
105
205
L3
106
206
317316315314313
207208209210
4
13 3
12 2
11 1
16
64 63
73 74
64 63
73 74
10 14
atys_719_b_1_gb_cat
RJ
RJ
15
5 6 7 8 9
13 14 24 34 43 44 53 54
13 14 24 34 43 44 53 54
1 Priority source 13: DTT inhibit input. Transfer initiated as soon as the input is closed when
DTT = max. value.
2 Backup source
14: fault output
1: position 0 control
15: remote control interface
2: position I control
16: slots for optional modules
3: position II control
17: 3 current transformers (Cts) for ATyS metering
4: position control inhibition inputs (0-I-II)
18: by-pass position
5: auxiliary contact, closed when the switch is in position I
19: ATS position
6: auxiliary contact, closed when the switch is in position II
20: 1 Priority source used
7: auxiliary contact, closed when the switch is in position 0
21: 2 Backup source used
8: auxiliary contact, closed when the switch is on “AUT” mode
101 - 102: supply 1 220 -20% / 240 +20%
9: auxiliary contact, closed when the switch is padlocked
201 - 202: supply 2 220 -20% / 240 +20%
10: gen-set start command
11: auxiliary power supply (for optional modules control)
12: remote “test on-load ”input
atys_448_b_1_cat
atys_448_b_1_cat
atys_599_b_1_cat
ATyS VISION Software
Other Changeover Switches
References
ATyS C20 ATyS C30 ATyS C40
References References References
Supplied from measurement circuit 15993020 G 15993030 G -
Power supply DC 15993021 G 15993031G 15993040G
Functions Characteristics
ATyS C30 / C40 allows any type of Supplied from measurement circuit 110 … 400 VAC
changeover control: ATyS 3, SMV, Power supply DC < 9 … 30 VDC
contactors, circuit breakers or other Measurement range 110 … 400 VAC± /10 %
motorised switches. Fréquence 50 / 60 Hz
ATyS C20
Accuracy ± 1%
Conformity to Applications
atys_448_b_1_cat
4 5
atys_566_b_1_x_cat
General characteristics
atys_149_e_1_x_cat
• Modular design (6 modules).
• DIN rail mounting.
• 2 outputs relays for changeover control. ATyS 3s
atys_448_b_1_cat
ATyS 3s
1. Measurement and power supply 1 & 1’. Generating sets measurment
2. Control and position information feedback 2. Control and position information feedback
ATyS C20 / C30 3. Generating set “start/stop” 3 & 3’. Generating set “start/stop” control
4. ATyS interface connection 4. External “start/stop” command for basic cycle
• ATyS D10 or D20 possible connection. (Only for C30)
5. DC power supply
• Inputs for auxiliary contacts position.
• Metering 3U on network 1.
• Metering 1U on network 2.
Terminals
6 7 8 9 10 6 7 8 9 10
• 1 start/stop generator contact.
ATyS C20 / C30 ATyS C40
• Programmable inputs.
• Programmable outputs.
1 2 3 4 5 1 2 3 4 5
ATyS C40
• Dual gensets controller with
a redundant genset application cycle.
atys_599_b_1_cat
atys_418_b_1_x_cat
atys_567_a_1_x_cat
11 12 11 12
• Single phase sensing on Gen1 & Gen 2.
N L3 L2 L1 L1’ L3’ L3 L1 L1’ L3’
• Programmable inputs.
103 104 105 106 203 205 104 106 203 205
• Programmable output.
• 2 start Gen contacts (Gen1 & Gen2). 1. Generator 1 start / stop control 8. CA2 : auxiliary contact position 2 1. Generator 1 start / stop control 7. I3 : programmable input
2. Pos 1: control 9. I1 : programmable input 2. Pos 1: control 8. CA2 : auxiliary contact position2
3. Pos 2: control 10. I2 : programmable input 3. Pos 2: control 9. I1 : programmable input
4. O1 programmable output 11. 3 U network 1 and alimentation 4. O1 programmable output 10. I2 : programmable input
5. O2 programmable output measurement 5. Generator 2 start / stop control 11. Metering 1U + frequency generator 1
6. CA1: auxiliary contact position 1 12. 1 U network 2 and alimentation 6. CA1: auxiliary contact position1 12. Metering 1U + frequency generator 2
7. CA0 : auxiliary contact position 0 measurement
atys_608_a_1_x_cat
It operates in a Windows® 98, NT4 (pack 6),
Millenium, 2000 or XP environment with a
minimum PC configuration of: Pentium ® II,
64 Mb RAM, hard disk space of at least
200 Mb, one or more RS232 or RS485
serial ports, a 17” VGA 1024 x 768 screen.
ATyS configuration
Settings:
General characteristics - communication parameters,
The ATyS VISION software allows you - automatic recognition product.
to visualise:
- product status, Configuration:
- all instantly measured electrical values, - product configuration,
- product configuration parameters, - network type,
- voltage and frequency thresholds,
atys_609_a_1_x_cat
- timer values,
- input and output status. - timers,
- inputs/outputs,
For each ATyS, you can export the - Excel import or export capability.
couv_128_a_1_cat
atys_610_a_1_x_cat
- source status, switch position.
atys_611_a_1_x_cat
485
bd_03_03_01
232
atys_572_a_1_gb_cat
ATyS VISION
Software
PC
atys_003_a_1_cat
Do not hesitate to consult us. a UPS (I, I+II, II).
• VDE 0660-107 (1992) • Emergency manual operation.
bd_03_04_01
They provide switching, source inversion to switch from one to the other under
and changeover under load for two low of different power ratings.
load (AC-22 and AC-23).
voltage power circuits, as well as their • Fully visible breaking.
atys_725_a_1_cat
safety isolation. • Double visible breaking.
ATyS 63 to 100A