Download as pdf or txt
Download as pdf or txt
You are on page 1of 94

FibeAir® RFU-C

Installation Guide

Part ID: BM-0133-0


Doc ID: DOC-00017708 Rev H
June 2012

Copyright © 2012 by Ceragon Networks Ltd. All rights reserved.


FibeAir® RFU-C Installation Guide

Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this
publication may be reproduced, modified, or distributed without prior written authorization of
Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Registered Trademarks
Ceragon Networks® is a registered trademark of Ceragon Networks Ltd. FibeAir® is a registered
trademark of Ceragon Networks Ltd. CeraView® is a registered trademark of Ceragon Networks
Ltd. Other names mentioned in this publication are owned by their respective holders.

Trademarks
CeraMap™, PolyView™, EncryptAir™, ConfigAir™, CeraMon™, EtherAir™, and MicroWave Fiber™,
are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned
by their respective holders.

Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon
Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential
damage in connection with the furnishing, performance, or use of this document or equipment
supplied with it.

Open Source Statement


The Product may use open source software, among them O/S software released under the GPL or
GPL alike license ("GPL License"). Inasmuch that such software is being used, it is released under
the GPL License, accordingly. Some software might have changed. The complete list of the
software being used in this product including their respective license and the aforementioned
public available changes is accessible on http://www.gnu.org/licenses/.

Ceragon Proprietary and Confidential Page 2 of 94


FibeAir® RFU-C Installation Guide

Revision History
Rev Date Author Description Approved by Date
B December 15, B. Gitlin Revised for description of captive Rami Lerner December 18, 2011
2011 screw installation.
C December 26, B. Gitlin Revised procedure for remote Rami Lerner December 26, 2011
2011 installation of OMT, added
procedure for installation of Ericsson
adapter for RAU1 radios.
D January 22, B. Gitlin Added 4+0/4+4 with symmetrical Rami Lerner January 22, 2012
2012 couplers.
E January 24, B. Gitlin Added 31 GHz support. Rami Lerner January 26, 2012
2012
F March 4, 2012 B. Gitlin Revised marketing models. Rami Lerner March 4, 2012
G May 6, 2012 I. Benoliel/ Added 42 GHz support, revised Rami Lerner May 6, 2012
B. Gitlin marketing models.
H June 24, 2012 Baruch Gitlin Add list of test kits and replace Rami Lerner June 24, 2012
graphic in Step 4 of 2+0 Dual
Polarization – Direct Mount
Installation.

Ceragon Proprietary and Confidential Page 3 of 94


FibeAir® RFU-C Installation Guide

Table of Contents
1. Important Notes ................................................................................................ 9

2. Acronyms .......................................................................................................... 9
3. RFU-C Overview ............................................................................................. 10
4. Installing an RFU-C ........................................................................................ 11
4.1 Packing......................................................................................................................... 11
4.2 Transportation .............................................................................................................. 11
4.3 Inspection ..................................................................................................................... 11
4.4 Installation Components............................................................................................... 12
4.5 Available Adapters and Installation Kits ....................................................................... 13
4.6 Antenna Connection..................................................................................................... 17

5. Cable Installation and Grounding.................................................................. 18


6. Generic Installation Procedures .................................................................... 19
6.1 Remote Mount Installation with Imperial Waveguide ................................................... 19
6.2 OMT WG Adaptor Installation ...................................................................................... 22

7. RFU-C Configurations .................................................................................... 24


7.1 1+0 Direct Mount Installation ....................................................................................... 24
7.2 1+0 Remote Mount Installation .................................................................................... 26
7.3 1+1 Direct Mount Installation ....................................................................................... 28
7.4 1+1 Remote Mount Installation .................................................................................... 31
7.5 2+0 Dual Polarization – Direct Mount Installation ........................................................ 33
7.6 2+0 Dual Polarization – Remote Mount Installation ..................................................... 37
7.6.1 OMT WG Adaptor Installation ...................................................................................... 38
7.6.2 1+0 Ready for 2+0 Dual Polarization – Direct Mount Installation ................................ 39
7.7 2+0 Single Polarization – Direct Mount Installation – Symmetrical Couplers .............. 41
7.8 2+0 Single Polarization – Direct Mount Installation – Asymmetrical Couplers ............ 44
7.9 2+2 Dual Polarization – Remote Mount Installation ..................................................... 45
7.10 4+0 Single Polarization – Remote Mount Installation .................................................. 47
7.11 4+0 Dual Polarization – Remote Mount Installation ..................................................... 51
7.12 4+4 Dual Polarization – Remote Mount Installation ..................................................... 54

8. Installing an RFU-C External Attenuator ....................................................... 59


8.1 1+0 Mount Configuration .............................................................................................. 59
8.2 1+1 HSB with External Attenuator Configuration ......................................................... 61

Ceragon Proprietary and Confidential Page 4 of 94


FibeAir® RFU-C Installation Guide

9. Installing RFU-C on Third-Party Antenna Adapters ..................................... 63


9.1 Direct Mount for NSN FlexiHopper Antennas .............................................................. 64
9.2 Installing an RFU-P Antenna Adaptor .......................................................................... 67
9.3 Installing an RFU-C Adaptor to Ericsson Antennas (RAU1 Radios) ........................... 73
9.3.1 Connecting the Adaptor Kit to the Ericsson Antenna ................................................... 73
9.3.2 Connecting the RFU to the Ericsson Antenna ............................................................. 74
9.4 Installing an RFU-C Adaptor to Ericsson 0.3m Compact Antennas (RAU2 Radios) ... 75
9.4.1 Connecting the Adaptor Kit to the Ericsson 0.3m Compact Antenna .......................... 75
9.4.2 Connecting the RFU to the Ericsson Antenna ............................................................. 77
9.5 Installing an RFU-C – NEC Adapter (PASOLINK NEO) .............................................. 78
9.6 Installing an RFU-C – SRAL Adaptor ........................................................................... 82
9.7 Installing an ALU Melody Adapter ................................................................................ 85
9.8 Converting from Nera ODU to RFU-C ......................................................................... 89

10. Appendix A: Mediation Device Losses ......................................................... 93

11. Appendix B: Test Kit Part Numbers .............................................................. 94

Ceragon Proprietary and Confidential Page 5 of 94


FibeAir® RFU-C Installation Guide

Safety Precautions & Declared Material


General Equipment Precautions

Use of controls, adjustments, or performing procedures other than those


! specified herein, may result in hazardous radiation exposure.

When working with a FibeAir IDU, note the following risk of electric
shock and energy hazard: Disconnecting one power supply disconnects
! only one power supply module. To isolate the unit completely,
disconnect all power supplies.

Machine noise information order - 3. GPSGV, the highest sound pressure


! level amounts to 70 dB (A) or less, in accordance with ISO EN 7779.
Static electricity may cause body harm, as well as harm to electronic
components inside the device.
Anyone responsible for the installation or maintenance of the FibeAir RFU-C
must use an ESD Wrist Strap.
ESD protection measures must be observed when touching the RFU.
To prevent damage, before touching components inside the device, all
electrostatic must be discharged from both personnel and tools.

! In Norway and Sweden:


Equipment connected to the protective earthing of the building installation
through the mains connection or through other equipment with a connection
to protective earthing – and to a cable distribution system using coaxial cable,
may in some circumstances create a fire hazard. Connection to a cable
distribution system has therefore to be provided through a device providing
electrical isolation below a certain frequency range (galvanic isolator, see EN
60728-11).
Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet
jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.
Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via
annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall
medfőra risk főr brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen
och kabel-TV nätet.

Ceragon Proprietary and Confidential Page 6 of 94


FibeAir® RFU-C Installation Guide

Précautions générales relatives à l'équipement

L’utilisation de commandes ou de réglages ou l'exécution de procédures


! autres que celles spécifiées dans les présentes peut engendrer une
exposition dangereuse aux rayonnements.

L’usage de FibeAir IDU s’accompagne du risque suivant d'électrocution


et de danger électrique : le débranchement d'une alimentation
! électrique ne déconnecte qu'un module d'alimentation électrique. Pour
isoler complètement l'unité, il faut débrancher toutes les alimentations
électriques.

Bruit de machine d’ordre - 3. GPSGV, le plus haut niveau de pression


! sonore s'élève à 70 dB (A) au maximum, dans le respect de la norme ISO
EN 7779.

Allgemeine Vorsichtsmaßnahmen für die Anlage

Wenn andere Steuerelemente verwendet, Einstellungen vorgenommen


! oder Verfahren durchgeführt werden als die hier angegebenen, kann
dies gefährliche Strahlung verursachen.

Beachten Sie beim Arbeiten mit FibeAir IDU das folgende Stromschlag-
und Gefahrenrisiko: Durch Abtrennen einer Stromquelle wird nur ein
! Stromversorgungsmodul abgetrennt. Um die Einheit vollständig zu
isolieren, trennen Sie alle Stromversorgungen ab.

Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste


! Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß EN ISO 7779.

Ceragon Proprietary and Confidential Page 7 of 94


FibeAir® RFU-C Installation Guide

About This Guide


This guide describes the FibeAir RFU-C installation procedures and provides
additional information concerning system parts and frequency bands.

What You Should Know


RFU-C is a state-of-the-art Radio Frequency Unit which is fully software
configurable and supports a broad range of capacities and interfaces. The RFU
supports low to high capacities for traditional voice and Ethernet services, as well
as PDH/SDH/SONET or hybrid Ethernet and TDM interfaces.
Important! For the warranty to be honored, install the unit in accordance
with the instructions in this manual.

Target Audience
This guide contains technical information about RFU-C installation, and is
intended for use by qualified Ceragon technical personnel at all levels.

Related Documents
 FibeAir 1500R Installation Guide - DOC-00017707
 FibeAir IP-10G Installation Guide –DOC-00023199
 FibeAir IP-10E Installation Guide –DOC-00029444
 FibeAir IP-10Q Installation Guide – DOC-00029546

Ceragon Proprietary and Confidential Page 8 of 94


FibeAir® RFU-C Installation Guide

1. Important Notes
 RFU-C is intended for installation in a Restricted Access Location.
 RFU-C must be installed and permanently connected to protective earth by
qualified service personnel in accordance with applicable national
electrical codes.

2. Acronyms
CCDP Co-Channel Dual Polarization
IDU Indoor Unit
OMT Orthogonal Mode Transducer
RFU Radio Frequency Unit
WG Waveguide
XPD Cross Polar Differentiation
XPIC Cross Polarization Interference Cancellation

Ceragon Proprietary and Confidential Page 9 of 94


FibeAir® RFU-C Installation Guide

3. RFU-C Overview
RFU-C is a state-of-the-art Radio Frequency Unit which is fully software
configurable and supports a broad range of capacities and interfaces.
The RFU supports low to high capacities for traditional voice and Ethernet
services, as well as PDH/SDH/SONET or hybrid Ethernet and TDM interfaces.
This innovative platform uses an “on-the-fly” upgrade method, whereby
network operators only buy capacity as needed, benefiting from savings on
initial investments and OPEX.
Traffic capacity throughput and spectral efficiency are optimized with the
desired channel bandwidth. For maximum user choice flexibility, channel
bandwidths can be selected together with a range of modulations of from
QPSK to 256 QAM.
High spectral efficiency is ensured using the same bandwidth for double the
capacity, via two carriers, with vertical and horizontal polarizations. This
feature is implemented by a built-in XPIC mechanism.
RFU-C works together with several types of indoor units (IDUs). For
PDH/SDH/SONET, the RFU works with the FibeAir 1500R IDU. For Ethernet
and TDM to Ethernet migration, RFU-C works with the FibeAir IP-10G IDU. For
Ethernet only, RFU-C works with the FibeAir IP-10E and FibeAir IP-10Q IDUs.
Together, FibeAir RFU-C and FibeAir IDUs provide a powerful, reliable, and
comprehensive solution for a variety of wireless network scenarios and
requirements.
When RFU-C operates in co-channel dual polarization (CCDP) mode, using the
cross polarization interference canceller (XPIC) algorithm, two carrier signals
can be transmitted over a single channel, using vertical and horizontal
polarization. This enables double capacity in the same spectrum bandwidth.

Ceragon Proprietary and Confidential Page 10 of 94


FibeAir® RFU-C Installation Guide

4. Installing an RFU-C
This section describes the basic types of RFU-C installation.

4.1 Packing
The equipment should be packed and sealed with moisture absorbing bags.

4.2 Transportation
The equipment should be prepared for public transportation. The cargo must
be kept dry during transportation, in accordance with ETS 300 019-1-2, Class
2.3.
It is recommended that the equipment be transported to the installation site
in its original packing case.
If intermediate storing is required, the packed equipment must be stored in a
dry and cool environment, and out of direct sunlight, in accordance with ETS
300 019-1-1, Class 1.2.

4.3 Inspection
Check the packing lists and verify that the correct equipment part numbers
and quantities are found in the packages that arrived.

Ceragon Proprietary and Confidential Page 11 of 94


FibeAir® RFU-C Installation Guide

4.4 Installation Components


The following figures show the main components involved in the installation
procedures.

RFU-C Coupler OMT

Remote Pole Mount Remote Dual Pole 4+0/4+4 Extender


Remote Mount

Twist Remote Mount for 4+0

Ceragon Proprietary and Confidential Page 12 of 94


FibeAir® RFU-C Installation Guide

4.5 Available Adapters and Installation Kits

Description 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C COUPLER KIT RFU-C6- RFU-C7_8- RFU- RFU-C13- RFU-C15- RFU-C18-CPLR- RFU-C23- RFU-C26- RFU-C28- RFU- RFU- RFU-C42-
CPLR-Kit CPLR-Kit C10_11- CPLR-Kit CPLR-Kit*0 Kit*0 CPLR-Kit CPLR-Kit CPLR-Kit C32- C38- CPLR_Kit
CPLR-Kit CPLR- CPLR-
Kit Kit

RFU-C SYMMETRICAL NA RFU-C7_8-Sym- NA RFU-C13- RFU-C15- RFU-C18-Sym- RFU-C23- NA


COUPLERS KIT cplr-kit Sym-cplr-kit Sym-cplr-kit cplr-kit Sym-cplr-kit

RFU-C TWIST KIT RFU-C6- RFU-C7_8- RFU- RFU-C13- RFU-C15- RFU-C18-TWST- RFU-C23_26-TWST-Kit RFU-C28_32-TWST-Kit RFU- RFU-C42-
TWST-Kit TWST-Kit C10_11- TWST-Kit TWST-Kit Kit C38- TWST-Kit
TWST-Kit TWST-
Kit

RFU-C OMT KIT RFU-C6- RFU-C7_8- RFU- RFU-C13- RFU-C15- RFU-C18-OMT- RFU-C23- RFU-C26- RFU-C28- RFU- RFU- RFU-C42-
OMT-DM-Kit OMT-DM-Kit C10_11- OMT-DM-Kit OMT-DM-Kit DM-Kit OMT-DM-Kit OMT-DM-Kit OMT-DM-Kit C32- C38- OMT-DM-
OMT-DM-Kit OMT- OMT- Kit
DM-Kit DM-Kit

RFU-C ADAPTORS RFU-C6- RFU-C7_8- RFU- NA


OMT KIT OMT-ADAPT OMT-ADAPT C10_11-
OMT-ADAPT

RFU-C SHORT OMT KIT RFU-C-OMT-SHORT-PLATE

Ceragon Proprietary and Confidential Page 13 of 94


FibeAir® RFU-C Installation Guide

Remote Mount 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C REMOTE RFU-C-PoleMount


MOUNT KIT

RFU-C Dual Remote RFU-C Dual Pole Mount


Mount

RFU-C Remote mount RFU-C_4+0_RM_Kit


4+0/4+4 pole mount kit

RFU-C ADAPTOR RFU-C6- RFU-C7_8- RFU- RFU-C13-


REMOTE MOUNT KIT RM_ADAPT RM_ADAPT C10_11- RM_ADAPT
RM_ADAPT

RFU-C WG Kit Flx-WG-4FT- Flx-WG-4FT- Flx-WG-4FT- Flx-WG-3FT- Flx-WG-3FT- Flx-WG-3FT-18-26 Flx-WG-3FT-28-38 Flx-WG-
6 7_8 10_11 13 15 3FT-42

RFU-C ADAPTOR TO ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU-C18_26-RM_mill ADPT_RFU-C28_38-RM_mill


FLEX WG (IMPERIAL) KIT C6-RM_mill ADPT_RFU- C10_11- ADPT_RFU- C15-RM_mill
C7_8-RM_mill RM_mill C13-RM_mill

1500P Adaptors 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C-PHOSPHORUS ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU- NA
DM ADAPTOR KIT C10_11- C13- C15- C18- C23- C26- C28- C32- C38-
DM_1500P DM_1500P DM_1500P DM_1500P DM_1500P DM_1500P DM_1500P DM_1500P DM_1500P

Ceragon Proprietary and Confidential Page 14 of 94


FibeAir® RFU-C Installation Guide

Imperial to mm
Transitions 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C ADAPTOR KIT ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU-C13- ADPT_RFU- ADPT_RFU-C18_26-RM_Imp ADPT_RFU-C28_38-RM_Imp NA
TO IMPERIAL ANT. C6-RM_Imp C7_8- C10_11- RM_Imp C15-RM_Imp
RM_Imp RM_Imp

RFU-C ADAPTOR KIT ADPT_RFU- ADPT_RFU- ADPT_RFU- ADPT_RFU-C13- ADPT_RFU- ADPT_RFU-C18_26-RM_mill ADPT_RFU-C28_38-RM_mill NA
TO IMP WG C6-RM_mill C7_8-RM_mill C10_11- RM_mill C15-RM_mill
RM_mill

Unique Installations 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz
and Accessories

RFU-C 19in RFU-C_19-inch_rack_adapt


MOUNTING KIT

RFU-C External 20dB RFU-C38- NA


Attenuator attn-20

Ceragon Proprietary and Confidential Page 15 of 94


FibeAir® RFU-C Installation Guide

Antenna 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz 42GHz
Circ.
Adapters
for OMT

Andrew RFU-C6-OMT- RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- RFU-C32- RFU-C38- RFU-C42-
INT-A OMT-INT-A OMT-INT-A INT-A INT-A INT-A INT-A INT-A INT-A OMT-INT-A OMT-INT-A OMT-INT-A

RFS 1FT NA NA NA RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- RFU-C32- RFU-C38- NA
INT-1FT-R INT-1FT-R INT-1FT-R INT-1FT-R INT-1FT-R INT-1FT-R OMT-INT- OMT-INT-
1FT-R 1FT-R

RFS 2-6FT RFU-C6-OMT- RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- RFU-C32- RFU-C38- NA
INT-2_6FT-R OMT-INT- OMT-INT- INT-2_6FT-R INT-2_6FT-R INT-2_6FT-R INT-2_6FT-R INT-2_6FT-R INT-2_6FT-R OMT-INT- OMT-INT-
2_6FT-R 2_6FT-R 2_6FT-R 2_6FT-R

GD RFU-C6-OMT- RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- RFU-C32- RFU-C38- NA
INT-GD OMT-INT-GD OMT-INT-GD INT-GD INT-GD INT-GD INT-GD INT-GD INT-GD OMT-INT-GD OMT-INT-GD

Radio RFU-C6L- RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- NA RFU-C38- NA
Waves OMT-INT-RW / OMT-INT-RW OMT-INT-RW INT-RW INT-RW INT-RW INT-RW INT-RW INT-RW OMT-INT-RW
RFU-C6H-
OMT-INT-RW

Shenglu RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT-


OMT-INT-SH OMT-INT-SH INT-SH INT-SH INT-SH INT-SH INT-SH

Xian Putian RFU-C6-OMT- RFU-C7_8- RFU-C10_11- RFU-C13-OMT- RFU-C15-OMT- RFU-C18-OMT- RFU-C23-OMT- RFU-C26-OMT- RFU-C28-OMT- RFU-C32- RFU-C38- NA
INT-X OMT-INT-X OMT-INT-X INT-X INT-X INT-X INT-X INT-X INT-X OMT-INT-X OMT-INT-X

Ceragon Proprietary and Confidential Page 16 of 94


FibeAir® RFU-C Installation Guide

4.6 Antenna Connection


RFU-C uses Andrew, General Dynamics, RFS, Shenglu and Xian Putian
antennas.
RFU-C can be mounted directly for all frequencies (6-42 GHz) using the
following antenna types (for integrated antennas, specific antennas PNs are
required):
 Andrew: VHLP series
 RFS: SB/SU series
 Shenglu: SLC series
 Xian Putian: WTC/WTG series
 General Dynamics: HPS series
For remote mount installations, the following flexible waveguide flanges
should be used (millimetric). The same antenna type (integrated) as indicated
above can be used (recommended).
Other antenna types using the flanges listed in the table below may be used.

Frequency Circ. WG Rect. WG Flange Des. Radio Side (Remote) Flex WG Side A Flex WG Side B Antenna (Remote)
Diameter Flange Des. Flange Des. Flange Des. Flange Des.
Band Range (GHz)

6(L/U) GHz 5.8-7.1 31.8mm WR137 UDR70 PDR70 PDR70 UDR70


7/8 GHz 7.1-8.5 26mm WR112 UBR84 PBR84 PBR84 UBR84
10/11 GHz 10.0-11.7 18mm WR90 UBR100 PBR100 PBR100 UBR100
13 GHz 12.7-13.3 15mm WR75 UBR120 PBR120 PBR120 UBR120
15 GHz 14.5-15.4 13.5mm WR62 UBR140 PBR140 PBR140 UBR140
18 GHz 17.7-19.7 10.5mm WR42 UBR220 PBR220 PBR220 UBR220
23 GHz 21.2-23.6 9mm
26 GHz 24.5-26.6 8mm
28-31GHz 27.3-29.5 7mm WR28 UBR320 PBR320 PBR320 UBR320
32GHz 31.8-33.4 6.5mm
38GHz 37.0-40.0 5.5mm
42GHz 40.5-43.5 4.775mm WR22 UG383/U UG383/U UG383/U UG383/U

If a different antenna type (CPR flange) is used, a flange adaptor is required.


Please contact your Ceragon representative for details.
Note: Conductive grease must be applied to the screws that
connect the RFU-C to the antenna interface.

Ceragon Proprietary and Confidential Page 17 of 94


FibeAir® RFU-C Installation Guide

5. Cable Installation and Grounding


List of Items

Item Description Quantity Remarks


1 IF RG-8 GRD KIT 1

Procedure

1 On the front side of each RFU-C unit, loosen the nut, plain washer, and
serrated washer.
2 Place the cable lug (supplied with the RFU-C grounding kit) on the screw.
3 Secure the cable lug.
RFU-C Grounding Cable

 The unit’s earthing screw terminal shall be permanently connected to


protective earth in a building installation in accordance with applicable
national code and regulations by a service person.
 A 2-Pole circuit breaker, a branch circuit protector, suitably certified in
accordance with applicable national code and regulations, rated maximum
20A, shall be installed for full power disconnection in a building
installation.
 Any outdoor antenna cable shield shall be permanently connected to
protective earth in a building installation.

Ceragon Proprietary and Confidential Page 18 of 94


FibeAir® RFU-C Installation Guide

6. Generic Installation Procedures

6.1 Remote Mount Installation with Imperial Waveguide

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1
3 FLEXIBLE WG IMPERIAL KIT 1
4 RFU-C REMOTE MOUNT ADAPTOR KIT 1 Up to 15 GHz
5 RFU-C REMOTE POLE MOUNT KIT 1

Required Tools

 Metric offset hexagon key wrench set


 Imperial offset hexagon key wrench set

Remote Mount Installation with an Imperial Waveguide – 6-11 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Adaptor kit on the
RFU-C Remote Pole Mount kit using the four flat screws supplied with the
RFU-C Adaptor kit.
2 Mount the RFU-C using the four captive screws and washers supplied,
assembled, in the RFU-C.

Ceragon Proprietary and Confidential Page 19 of 94


FibeAir® RFU-C Installation Guide

3 Connect the Flexible Waveguide and Sealing Gasket supplied with the
Flexible Waveguide Imperial kit to the RFU-C Adaptor. Tighten the four
screws supplied with the Flexible Waveguide Imperial kit.

Remote Mount Installation with an Imperial Waveguide – 13-15 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Remote Pole Mount kit
using the four flat screws supplied with the RFU-C Adaptor kit.
2 Mount the RFU-C using the four captive screws and washers supplied,
assembled, in the RFU-C.

Ceragon Proprietary and Confidential Page 20 of 94


FibeAir® RFU-C Installation Guide

3 Connect the Flexible Waveguide and sealing O-Ring supplied with the
Flexible Waveguide Imperial kit to the RFU-C Adaptor. Tighten the four
screws supplied with the Flexible Waveguide Imperial kit.

Remote Mount Installation with an Imperial Waveguide – 18-42 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Remote Pole Mount kit
using the four flat screws supplied with the RFU-C Adaptor kit.
2 Mount the RFU-C using the four captive screws and washers supplied,
assembled, in the RFU-C.
3 Connect the Flexible Waveguide and sealing O-Ring supplied with the
Flexible Waveguide Imperial kit. Tighten the four metric screws supplied
with the RFU-C Adaptor kit.

Ceragon Proprietary and Confidential Page 21 of 94


FibeAir® RFU-C Installation Guide

6.2 OMT WG Adaptor Installation


This procedure is applicable for all remote mount configurations that involve
an OMT.
1 For 6Ghz (UDR70):
i Mount the O-Ring supplied with the OMT kit.
ii Mount OMT Adaptor #1 on the OMT, and tighten using four M4 screws
and washers (supplied with the OMT adaptor kit).
iii Mount OMT Adaptor #2 on OMT Adaptor #1, and tighten using four M4
screws and washers (supplied with the OMT adaptor kit).

iv Mount the flexible waveguide as usual.


2 For 7-11 GHz (UBR84 and UBR100):
i Mount the O-Ring supplied with the OMT kit.
ii Mount the OMT adaptor, with its installed sealing gasket, on the OMT,
and tighten using the four M4 screws and washers supplied with the
OMT Adaptor kit.
iii Mount the flexible waveguide without its gasket (only for the OMT
side).

Ceragon Proprietary and Confidential Page 22 of 94


FibeAir® RFU-C Installation Guide

3. For 13 GHz (UBR120) to 42 GHz (UG383/U), connect the flexible


waveguide and its gasket (supplied with the Flexible WG Kit) directly
to the OMT port.

Ceragon Proprietary and Confidential Page 23 of 94


FibeAir® RFU-C Installation Guide

7. RFU-C Configurations

7.1 1+0 Direct Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1

Required Tools

The following tools are required for the RFU-C installation:


 Metric offset hexagon key wrench #6
 Phillips #2 screwdriver

Procedure

To install the RFU-C in a direct mount 1+0 configuration:


Important! Do not remove the transparent pressure window located on
the antenna interface.

Note: If necessary, change the antenna polarization by rotating the


RFU-C in accordance with the relevant antenna installation
guide.

Ceragon Proprietary and Confidential Page 24 of 94


FibeAir® RFU-C Installation Guide

Vertical Pole Horizontal Pole

1 Mount the RFU-C on the antenna using the four M8 captive screws and
washers that are supplied, assembled, in the RFU-C, and tighten the
screws.

Note: Make sure the polarization mounting direction of the RFU-C


is correct.
Ceragon Proprietary and Confidential Page 25 of 94
FibeAir® RFU-C Installation Guide

7.2 1+0 Remote Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1
2 RFU-C POLE MOUNT KIT 1
3 RFU-C REMOTE MOUNT ADAPTOR Kit 1 For 6-13 GHz

Required Tools

The following tools are required for the RFU-C installation:


 Metric offset hexagon key wrench #6
 Phillips #2 screwdriver

Procedure

1 For 6-13 GHz installations only, mount the RFU-C remote adaptor and
O-Ring to the pole mount using the four flat M5 screws supplied in the
RFU-C Remote Mount Adaptor kit, and tighten the screws.
2 Mount the RFU-C to the pole mount using the four M8 captive screws and
washers supplied, assembled, in the RFU-C, and tighten the screws.

3 Place the O-Ring in the flexible waveguide flange groove.


4 Place the O-Ring in the other end of the flexible waveguide flange groove.

Ceragon Proprietary and Confidential Page 26 of 94


FibeAir® RFU-C Installation Guide

5 Mount the flexible waveguide on the antenna, and tighten the screws and
washers.

Ceragon Proprietary and Confidential Page 27 of 94


FibeAir® RFU-C Installation Guide

7.3 1+1 Direct Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 2
4 RFU-C COUPLER KIT 1
5 RFU-C TWIST KIT 1

Required Tools

The following tools are required for the RFU-C installation:


 Metric offset hexagon key wrench #6
 Phillips #2 screwdriver
 Metric offset hexagon key wrench #2.5 and #3

Procedure

In 1+1 direct mount installation, the RFU-C is attached to a coupler. To install


a RFU-C in a direct mount 1+1 configuration:
Notes: For 15 and 18 GHz frequencies, two O-Rings are supplied in
the Twist kit and should be mounted in the twist grooves.
For 6 GHz frequency, a gasket is used instead of an O-Ring.
The gasket should be mounted between the twist and the
RFU-C Coupler kit.
1 Mount the twist to the coupler using the O-Ring and four screws supplied
in the Twist kit, and tighten the screws.

Ceragon Proprietary and Confidential Page 28 of 94


FibeAir® RFU-C Installation Guide

Important: Make sure the polarization mounting direction of the twist


to the coupler is according to the antenna polarization.

H V

2 Mount the coupler radio on the antenna using the four M8 screws and
washers supplied with the RFU-C Coupler kit, and tighten the screws.
3 Mount the two O-Rings supplied with the RFU-C Coupler kit, as shown in
the following figure.

Ceragon Proprietary and Confidential Page 29 of 94


FibeAir® RFU-C Installation Guide

4 Mount the RFU-C to the body of the coupler using the four M8 captive
screws and washers that are supplied, assembled, in the RFU-C, and
tighten the screws.

Ceragon Proprietary and Confidential Page 30 of 94


FibeAir® RFU-C Installation Guide

7.4 1+1 Remote Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 2
2 RFU-C POLE MOUNT KIT 1
3 RFU-C COUPLER KIT 1
4 RFU-C FLEXIBLE WG KIT 1

Required Tools

The following tools are required for the RFU-C installation:


 Metric offset hexagon key wrench #6
 Phillips #2 screwdriver
 Metric offset hexagon key wrench #2.5 and #3

Procedure

In 1+1 remote mount installation, the RFU-C radios are attached to a coupler,
while the coupler is connected to the antenna via flexible WG. To install the
RFU-C in a remote mount 1+1 configuration:
1 Mount the RFU-C coupler to the RFU-C pole mount bracket using the four
M8 screws and washers supplied with the RFU-C Coupler kit, and tighten
the screws.

2 Mount the two O-Rings supplied with the Coupler kit, according to the
Coupler kit instructions.

Ceragon Proprietary and Confidential Page 31 of 94


FibeAir® RFU-C Installation Guide

3 Mount the RFU-C on the body of the coupler using the four M8 captive
screws and washers that are supplied, assembled, in the RFU-C, and
tighten the screws.

6-13GHz 15-38GHz

4 Place the O-Ring in the flexible waveguide flange groove.


5 Mount the flexible waveguide on the coupler, and tighten the screws and
washers.
6 Place the O-Ring in the other end of the flexible waveguide flange groove.
7 Mount the flexible waveguide on the antenna, and tighten the screws and
washers.

Ceragon Proprietary and Confidential Page 32 of 94


FibeAir® RFU-C Installation Guide

7.5 2+0 Dual Polarization – Direct Mount Installation


CCDP

List of Items

Item Description Quantity Remarks


1 ANTENNA OMT ADAPTOR 1
2 RFU-C OMT KIT 1
3 RFU-C RADIO 2 One is optional if using item #4 or #5
4 RFU-C OMT ADAPTOR KIT 1 Optional (for 6, 7-8 and 10-11Ghz)
5 RFU-C OMT SHORT KIT 1 Optional

Required Tools

 Metric offset hexagon key wrench 6


 Metric offset hexagon key wrench 3

Ceragon Proprietary and Confidential Page 33 of 94


FibeAir® RFU-C Installation Guide

Procedure

Important! Do not remove the transparent pressure window located on


the antenna interface or the Mylar film on the OMT ports.

1 Prior to the installation, follow the antenna manufacturer’s instructions to


switch to circular adaptor (remove the existing rectangular transition,
swap the O-Ring, and install the circular transition instead).

2 Mount the OMT kit on the antenna using the four M8 screws and washers
supplied with the OMT kit. Do not tighten them yet, to enable rotation of
the entire assembly.

Ceragon Proprietary and Confidential Page 34 of 94


FibeAir® RFU-C Installation Guide

3 Mount the two O-Rings supplied with the OMT kit on the OMT body. Make
sure the mounting direction is correct, as shown in the section view.

Ceragon Proprietary and Confidential Page 35 of 94


FibeAir® RFU-C Installation Guide

4 Mount both RFUs, using the four M8 captive screws and washers supplied,
assembled, in the RFU-C, through the radio and OMT holder, and tighten
the screws. Make sure the polarization mounting direction is correct.

5 Tilt the entire assembly, as described in the XPIC link alignment


procedure, to achieve maximum XPD (Cross Polar Differentiation). After
link alignment, tighten the four M8 screws left open in step 2 above.

Ceragon Proprietary and Confidential Page 36 of 94


FibeAir® RFU-C Installation Guide

7.6 2+0 Dual Polarization – Remote Mount Installation


CCDP

When remote configuration is required, the OMT is attached directly to the


antenna and the RFUs are installed remotely, using flexible waveguides.

List of Items

Item Description Quantity Remarks


1 ANTENNA OMT ADAPTOR 1
2 RFU-C OMT KIT 1
3 RFU-C RADIO 2 One is optional if using item #5
4 RFU-C OMT ADAPTOR KIT 1 Optional (for 6, 7-8 and 10-11Ghz)
5 RFU-C OMT SHORT KIT 1 Optional
6 FLEXIBLE WG KIT 1 Optional
7 RFU-C REMOTE MOUNT KIT 1
8 RFU-C REMOTE MOUNT ADAPTOR KIT 2 For 6 to 13GHz

Required Tools

 Metric offset hexagon key wrench 6


 Metric offset hexagon key wrench 3

Ceragon Proprietary and Confidential Page 37 of 94


FibeAir® RFU-C Installation Guide

Procedure

Important! Do not remove the transparent pressure window located on


the antenna interface or the Mylar film on the OMT ports.

4. Prior to the installation, follow the antenna manufacturer’s


instructions to switch to circular adaptor (remove the existing
rectangular transition, swap the O-Ring, and install the circular
transition instead).

5. Mount the OMT kit on the antenna using the four M8 screws and
washers supplied with the OMT kit. Do not tighten them yet, to enable
rotation of the entire assembly.

7.6.1 OMT WG Adaptor Installation


1 Connect the flexible waveguides to the OMT ports either directly or using a
suitable adaptor as explained in OMT WG Adaptor Installation on page 22.
2 Connect the other end of the flexible waveguide to the RFU-C Radio port.
Note: For detailed remote mount installation instructions, refer to
1+0 Remote Mount Installation on page 26.

Ceragon Proprietary and Confidential Page 38 of 94


FibeAir® RFU-C Installation Guide

Note: Remote Configuration Frequencies 13-42 GHz do not


require adaptors.
Frequencies 6-11 GHz require adaptors, as described above.

7.6.2 1+0 Ready for 2+0 Dual Polarization – Direct Mount Installation
If you are installing a 1+0 configuration and you want to be prepared to
upgrade to a 2+0 configuration (for double capacity), a protective “short” can
be used to terminate the unused port. Later, when an additional RFU is
installed on the second port, the short should be removed.
The following steps describe the required items and procedures for the
installation.
1 Place the Plate in front of the coupler holder.
2 Tighten the plate to the upgradable port side with the M8 screws and
washers supplied with the RFU-C coupler short plate kit using 21.4 NM
torque.

Ceragon Proprietary and Confidential Page 39 of 94


FibeAir® RFU-C Installation Guide

Ceragon Proprietary and Confidential Page 40 of 94


FibeAir® RFU-C Installation Guide

7.7 2+0 Single Polarization – Direct Mount Installation –


Symmetrical Couplers
ACCP

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 2
2 RFU-C SYMMETRICAL COUPLER KIT 1
3 RFU-C TWIST KIT 1

Required Tools

 Metric offset hexagon key wrench #2.5, #3 and #6.

Procedure

1 Remove the Extender from the Symmetrical Coupler by opening and


removing the four M4 screws and washers, as shown in following figure.

Ceragon Proprietary and Confidential Page 41 of 94


FibeAir® RFU-C Installation Guide

2 Mount the twist to the Circulator/Symmetrical Coupler using the O-Ring


and four screws supplied in the Twist Kit. Tighten the screws.

Note: For 15 and 18 GHz frequencies, two O-Rings are supplied in


the Twist Kit and should be mounted in the twist grooves.
For 6 GHz frequency, a gasket is used instead of an O-Ring.
The gasket should be mounted between the twist and the
RFU-C Circulator/Symmetrical Coupler Kit.

Important! Make sure the polarization mounting direction of the twist


to the RFU-C circulator / symmetrical coupler is according
to the antenna polarization.

Ceragon Proprietary and Confidential Page 42 of 94


FibeAir® RFU-C Installation Guide

H V

3 Mount the Circulator/Symmetrical Coupler on the antenna using the four


M8 screws and washers supplied with the RFU-C Circulator/Symmetrical
Coupler Kit, and tighten the screws.
4 Mount the two O-Rings supplied with the RFU-C Circulator/Symmetrical
Coupler Kit.
5 Mount the two RFU-C radios to the body of the Circulator/Symmetrical
Coupler using the four M8 captive screws and washers that are supplied
assembled in the RFU-C, and tighten the screws.

Note: RFU-C mounting screws and washers can be supplied either


assembled on the RFU-C, or as a part of the RFU-C Kit.

Ceragon Proprietary and Confidential Page 43 of 94


FibeAir® RFU-C Installation Guide

7.8 2+0 Single Polarization – Direct Mount Installation –


Asymmetrical Couplers
ACCP

For detailed installation procedures, refer to 1+1 Direct Mount Installation on


page 28.
Important! When using asymmetrical couplers for a 2+0 single
polarization configuration, make sure to cross-install the
RFU-C units for an even system gain between both channels.

Freq1 Freq1

Standard 6.5dB Loss 1.5dB Loss Standard


coupler coupler
assembly 1.5dB Loss 6.5dB Loss assembly

Freq2 Freq2

Couplers are cross – installed to


get symmetrical system gain.

Ceragon Proprietary and Confidential Page 44 of 94


FibeAir® RFU-C Installation Guide

7.9 2+2 Dual Polarization – Remote Mount Installation


CCDP - Protected

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 4
2 RFU-C COUPLER KIT 2
3 RFU-C DUAL POLE REMOTE MOUNT KIT 1
4 RFU-C OMT KIT 1
5 FLEXIBLE WAVEGUIDE KIT 2

Procedure

Important! Do not remove the transparent pressure window located on


the antenna interface or the Mylar film on the OMT ports.

1 Prior to the installation, follow the antenna manufacturer’s instructions to


switch to circular adaptor (remove the existing rectangular transition,
swap the O-Ring, and install the circular transition instead).

Ceragon Proprietary and Confidential Page 45 of 94


FibeAir® RFU-C Installation Guide

2 Mount the OMT kit on the antenna using the four M8 screws and washers
supplied with the OMT kit. Do not tighten them yet, to enable rotation of
the entire assembly.
3 For 6 GHz to 11 GHz, connect the waveguide adaptors as described in OMT
WG Adaptor Installation on page 38.
4 For 13 GHz (UBR120) to 42 GHz (UG383/U), connect the flexible
waveguide and its gasket (supplied with the Flexible WG Kit) directly to
the OMT port.
5 Connect the other end of the flexible waveguide to each RFU-C Coupler
port mounted on the RFU-C Dual Pole Remote Mount Kit.

Ceragon Proprietary and Confidential Page 46 of 94


FibeAir® RFU-C Installation Guide

7.10 4+0 Single Polarization – Remote Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 4
2 RFU-C SYMMETRICAL COUPLERS KIT 3
3 RFU-C - REMOTE MOUNT KIT FOR 4+0 1

Required Tools

 Metric offset hexagon key wrench #2.5, #3, #6 and #8.Procedure


Note: Do not remove the transparent pressure window located on
the antenna interfaces.

1 Mount the Pole mount brackets, by tightening four M10 screws and
washers (supplied with the RFU-C-Remote Mount kit for 4+0).

Ceragon Proprietary and Confidential Page 47 of 94


FibeAir® RFU-C Installation Guide

2 Remove the Extender from one RFU-C Symmetrical Coupler by opening


and removing the four M4 screws and washers, as shown in following
figure:

3 Mount the RFU-C Symmetrical Coupler, without the Extender part, to the
RFU-C Pole mount bracket, by tightening four M8 screws and washers
(supplied with the RFU-C Coupler kit).

4 Mount two adaptor brackets (supplied in the RFU-C Remote Mount for 4+0
kit) to the RFU-C Symmetrical coupler by tightening four M8 screws and
washers (screws are supplied in the RFU-C Remote Mount Kit for 4+0).
Repeat the operation for both RFU-C Symmetrical couplers.

Ceragon Proprietary and Confidential Page 48 of 94


FibeAir® RFU-C Installation Guide

5 Mount the two O-Rings (supplied in the RFU-C Symmetrical Coupler kit).
Mount the two RFU-C Symmetrical couplers to the third one. For each
RFU-C Symmetrical coupler, use four M8 screws and washers (supplied in
the RFU-C Symmetrical Coupler kit).

Note: The O-ring is mounted with the flat bottom facing coupler.
6 Mount the two O-Rings (supplied in the RFU-C Symmetrical coupler kit).
7 Mount the two RFU-C radio units on each RFU-C Symmetrical coupler by
tightening the four M8 captive screws and washers (supplied assembled in
the RFU-C radio).

Ceragon Proprietary and Confidential Page 49 of 94


FibeAir® RFU-C Installation Guide

Note: RFU-C mounting screws and washers can be supplied either


assembled on the RFU-C, or as a part of RFU-C kit.
8 Connect the flexible waveguide to the RFU-C Symmetrical coupler using
the O-Ring and screws (supplied with the Flexible Waveguide kit). Connect
the other end of the flexible waveguide to the antenna.

Ceragon Proprietary and Confidential Page 50 of 94


FibeAir® RFU-C Installation Guide

7.11 4+0 Dual Polarization – Remote Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 4
2 RFU-C SYMMETRICAL COUPLER KIT 2
3 RFU-C OMT KIT 1
4 RFU-C DUAL POLE REMOTE MOUNT KIT 1
5 FLEXIBLE WAVEGUIDE KIT 2

Required Tools

 Metric offset hexagon key wrench #2.5, #3, #6 and #8.Procedure

Procedure

The procedure is similar to the 2+2 dual polarization procedure, except that
here, symmetrical couplers are used instead of asymmetrical couplers.
Important! Do not remove the transparent pressure window located on
the antenna interface or the Mylar film on the OMT ports.

Ceragon Proprietary and Confidential Page 51 of 94


FibeAir® RFU-C Installation Guide

1 Prior to the installation, follow the antenna manufacturer’s instructions to


switch to a circular adaptor (remove the existing rectangular transition,
swap the O-Ring, and install the circular transition instead).

2 Mount the OMT kit on the antenna using the four M8 screws and washers
supplied with the OMT kit. Do not tighten them yet, to enable rotation of
the entire assembly.
3 For 6 GHz to 11 GHz, connect the waveguide adaptors as described in OMT
WG Adaptor Installation on page 38.
4 For 13 GHz (UBR120) to 42 GHz (UG383/U), connect the flexible
waveguide and its gasket (supplied with the Flexible WG Kit) directly to
the OMT port.
5 Mount the pole mount brackets by tightening four M10 screws and
washers (supplied with the RFU-C-Remote Mount kit FOR 4+0).
6 Remove the Extender from the RFU-C symmetrical coupler by opening and
removing the four M4 screws and washers. Repeat this operation for both
RFU-C symmetrical couplers.

Ceragon Proprietary and Confidential Page 52 of 94


FibeAir® RFU-C Installation Guide

7 Mount both RFU-C symmetrical couplers, without the Extender part, to the
RFU-C remote mount bracket, by tightening the four M8 screws and
washers (supplied with each RFU-C Coupler kit).

8 Connect the other end of the flexible waveguide to each RFU-C


symmetrical coupler mounted on the RFU-C Remote mount bracket.

Ceragon Proprietary and Confidential Page 53 of 94


FibeAir® RFU-C Installation Guide

7.12 4+4 Dual Polarization – Remote Mount Installation

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 8
2 RFU-C SYMMETRICAL COUPLER KIT 4
3 RFU-C - REMOTE MOUNT KIT FOR 4+0 2
4 RFU-C COUPLER KIT 2
5 RFU-C OMT KIT 1
6 FLEXIBLE WAVEGUIDE KIT 2

Required Tools

 Metric offset hexagon key wrench #2.5, #3, #6 and #8.

Procedure

Important! Do not remove the transparent pressure window located on


the antenna interface or the Mylar film on the OMT ports.

1 Prior to the installation, follow the antenna manufacturer’s instructions to


switch to circular adaptor (remove the existing rectangular transition,
swap the O-Ring, and install the circular transition instead).

Ceragon Proprietary and Confidential Page 54 of 94


FibeAir® RFU-C Installation Guide

2 Mount the OMT kit on the antenna using the four M8 screws and washers
supplied with the OMT kit. Do not tighten them yet, to enable rotation of
the entire assembly.
3 For 6 GHz to 11 GHz, connect the waveguide adaptors as described in OMT
WG Adaptor Installation on page 38.
4 For 13 GHz (UBR120) to 42 GHz (UG383/U), connect the flexible
waveguide and its gasket (supplied with the Flexible WG Kit) directly to
the OMT port.
5 Mount the pole mount brackets by tightening four M10 screws and
washers (supplied with the RFU-C-Remote Mount kit for 4+0).
6 Remove the Extender from RFU-C symmetrical coupler by opening and
removing the four M4 screws and washers. Repeat this operation for both
RFU-C symmetrical couplers.
7 Mount the pole mount brackets by tightening four M10 screws and
washers (supplied with the RFU-C-Remote Mount kit for 4+0).

Ceragon Proprietary and Confidential Page 55 of 94


FibeAir® RFU-C Installation Guide

8 Remove the Extender from one RFU-C Symmetrical Coupler by opening


and removing the four M4 screws and washers, as shown in following
figure:

9 Mount the RFU-C symmetrical coupler, without the Extender part, to the
RFU-C pole mount bracket, by tightening four M8 screws and washers
(supplied with the RFU-C Coupler kit).

Ceragon Proprietary and Confidential Page 56 of 94


FibeAir® RFU-C Installation Guide

10 Mount two adaptor brackets (supplied in RFU-C Remote Mount for 4+0
kit) to the RFU-C symmetrical coupler by tightening the four M8 screws
and washers (screws are supplied in the RFU-C Remote Mount kit for 4+0).
Repeat the operation for both RFU-C symmetrical couplers.

11 Mount the two O-Rings (supplied in the RFU-C symmetrical coupler kit).
Mount the two RFU-C symmetrical couplers to the third one. For each
RFU-C Symmetrical coupler, use four M8 screws and washers (supplied in
the RFU-C Symmetrical Coupler kit).

Note: The O-Ring is mounted with the flat bottom facing the
coupler.

Ceragon Proprietary and Confidential Page 57 of 94


FibeAir® RFU-C Installation Guide

12 Mount the two O-Rings (supplied in the RFU-C Symmetrical Coupler kit).
Mount the two RFU-C radio units on each RFU-C symmetrical coupler by
tightening the four M8 captive screws and washers (supplied assembled in
the RFU-C radio).

Note: RFU-C mounting screws and washers can be supplied either


assembled on the RFU-C, or as a part of the RFU-C kit.
13 Connect the flexible waveguide to the RFU-C Symmetrical coupler using
the O-Ring and screws (supplied with the flexible waveguide kit). Connect
the other end of the Flexible Waveguide to one radio port polarization of
RFU-C OMT.
14 Repeat paragraphs 7 through 13 for the second polarization.

Ceragon Proprietary and Confidential Page 58 of 94


FibeAir® RFU-C Installation Guide

8. Installing an RFU-C External Attenuator


Required Tools

 Metric offset hexagon key wrench #6


 Phillips screwdriver #2

8.1 1+0 Mount Configuration

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1
2 RFU-C EXTERNAL ATTENUATOR 1

Procedure

1 Remove the stickers from the RFU-C External Attenuator carefully so that
the sealing gaskets remain in place.
2 Mount the RFU-C External Attenuator to the antenna using the four M8
screws and washers supplied with the RFU-C External Attenuator kit, and
tighten the screws.
The polarization mounting direction must be the same as that of the
antenna.

Ceragon Proprietary and Confidential Page 59 of 94


FibeAir® RFU-C Installation Guide

3 Mount the RFU-C to the RFU-C External Attenuator using the four M8
screws and washers supplied with the RFU-C Radio kit, and tighten the
screws.
The RFU-C radio mounting polarization should be mounted using the
same polarization as the RFU-C External Attenuator.

Ceragon Proprietary and Confidential Page 60 of 94


FibeAir® RFU-C Installation Guide

8.2 1+1 HSB with External Attenuator Configuration

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 2
2 RFU-C EXTERNAL ATTENUATOR 1
3 RFU-C COUPLER KIT 1
4 RFU-C TWIST 1

Procedure

1 Mount the O-Rings, RFU-C units, and RFU-C twist on the body of the RFU-C
coupler, as described in the Coupler kit instructions.
2 For each RFU-C, close the four M8 captive screws and washers supplied,
assembled in the RFU-C, and tighten the screws.
The polarization mounting direction of the RFU-C Twist must be the
same as that of the antenna.

3 Remove the stickers from the RFU-C External Attenuator carefully so that
the sealing gaskets remain in place.

Ceragon Proprietary and Confidential Page 61 of 94


FibeAir® RFU-C Installation Guide

4 Mount the RFU-C External Attenuator to the antenna using the four M8
screws and washers supplied with the RFU-C External Attenuator kit, and
tighten the screws.
The polarization mounting direction must be the same as that of the
antenna.

5 Mount the RFU-C coupler to the RFU-C External Attenuator using the four
M8 screws and washers supplied with the RFU-C Coupler kit, and tighten
the screws.

Ceragon Proprietary and Confidential Page 62 of 94


FibeAir® RFU-C Installation Guide

9. Installing RFU-C on Third-Party Antenna Adapters


The following table describes available adapters:

Other Vendors Antennas 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz

RFU-C - NEC Adaptor kit ADPT_RFU-C15-


(PASOLINK NEO) NC_ANT ADPT_RFU-C18_26-NEC_ANT

RFU-C - ERICSSON Adaptor kit ADPT_RFU-C13- ADPT_RFU-C15- ADPT_RFU-C18- ADPT_RFU-C23-26-


(RAU1) ERCS_RAU1_ANT ERCS_RAU1_ANT ERCS_RAU1_ANT ERCS_RAU1_ANT ADPT_RFU-C28-38-ERCS_RAU1_ANT

ADPT_RFU-
RFU-C - ERICSSON Adaptor kit C7_8- ADPT_RFU-C13- ADPT_RFU-C15- ADPT_RFU-C18-
(RAU2) ERCS_ANT ERCS_ANT ERCS_ANT ERCS_ANT ADPT_RFU-C23-ERCS_ANT ADPT_RFU-C28_38-ERCS_ANT

RFU-C - SRAL (SIEMENS)


Adaptor kit MK-4161-0 MK-4162-0 MK-4163-0 ADPT_RFU-C18_26-SRAL_ANT ADPT_RFU-C28_38-SRAL_ANT

RFU-C-NSN (Flexihopper) ADPT_RFU- ADPT_RFU-C13- ADPT_RFU-C15- ADPT_RFU-


ADAPTOR KIT C7_8-N_ANT N_ANT N_ANT ADPT_RFU-C18_26-N_ANT C38-N_ANT

ADPT_RFU-C13-
RFU-C - ALU Adapter Kit ALU_Melody ADPT_RFU-C18-ALU_Melody

Kit for converting a ValuLine 3


antenna for integration with RFU- VINTA-6W- VINTA-7W- VINTA-11W- VINTA-23- VINTA-26- VINTA-28- VINTA-32- VINTA-38-
1
C (ValuLine 3 antennas only) CR4A CR4A CR4A VINTA-13-CR4A VINTA-15-CR4A VINTA-18-CR4A CR4A CR4A CR4A CR4A CR4A

1
These part numbers are valid for any ValuLine 3 antenna, integrated or non-integrated. This kit may also be used to convert Andrew VL3 antennas with the old
Nera Evolution interface to RFU-C.

Ceragon Proprietary and Confidential Page 63 of 94


FibeAir® RFU-C Installation Guide

9.1 Direct Mount for NSN FlexiHopper Antennas


RFU-C can be directly mounted on a NSN FlexiHopper 6-42 GHz, 1-6 ft
antenna, in 1+0 and 1+1 configurations.
An adapter is used for the direct mount, as shown in the following figure.

Note: This adapter is for the NSN Flexihopper antenna.

List of Items

Item Description Quantity


1 RFU-C NSN INTERFACE 1
2 RFU-C O-RING 1
3 RFU-C RADIO 1
4 SCREW SOCKET HEAD M8 4
5 WASHER SPRING LOCK FOR M8 4

Required Tools

 Metric offset hexagon key wrench 6

Ceragon Proprietary and Confidential Page 64 of 94


FibeAir® RFU-C Installation Guide

Procedure

Important! Do not remove the transparent pressure window located on


the antenna interface.
1 Check that the gasket is already mounted on the NSN interface side.
Note: For UBR84 (7GHz), insert the gasket on the NSN
antenna/coupler side.

2 Insert the O-Ring in its groove at the rear side of the RFU-C. Make sure the
mounting direction is correct, as shown in the section view.

3 Insert the four screws and washers supplied with the RFU-C through the
RFU-C and NSN adapter, and tighten the screws.

Ceragon Proprietary and Confidential Page 65 of 94


FibeAir® RFU-C Installation Guide

The following figure shows the RFU mounted to the NSN antenna.

Ceragon Proprietary and Confidential Page 66 of 94


FibeAir® RFU-C Installation Guide

9.2 Installing an RFU-P Antenna Adaptor


When mounting an RFU-C on an antenna upon which an 1500P (11-38 GHz)
direct mount was previously installed, the following adaptor is required
(frequency-dependent).

List of Items

Item Description Quantity Remarks


1 RFU-C/RFU-P DIRECT MOUNT INTERFACE 1
2 RFU-C RADIO 1 or 2
3 RFU-C COUPLER 1 Optional

Required Tools

 Metric offset hexagon key wrench #6


 Metric offset hexagon key wrench #3
 Screwdriver Phillips #2

Ceragon Proprietary and Confidential Page 67 of 94


FibeAir® RFU-C Installation Guide

Procedure

1 Prior to the installation, check the polarization definition on the RFU-P


antenna. Also check that the O-Ring is mounted properly on the RFU-P
antenna.

2 The RFU-C/RFU-P interface is mounted with vertical polarization by


default. If necessary, switch the polarization by releasing four countersink
screws, rotating the central adaptor 90 degrees, and re-tightening the
screws.

Ceragon Proprietary and Confidential Page 68 of 94


FibeAir® RFU-C Installation Guide

3 Mount the O-Ring supplied in the RFU-C/RFU-P Interface kit on the RFU-
C/ RFU-P interface. Make sure the mounting direction is correct, as shown
in the section view.

For 1+0 Mounting:


Important! Do not remove the transparent pressure window located on
the antenna interface.

4 Mount the RFU-C to the RFU-P Interface, using the four M8 captive screws
and washers supplied with the RFU-C kit, and tighten the screws.
Note: RFU-C mounting screws and washers can be supplied either
assembled on RFU-C, or as a part of RFU-C Kit.
Make sure the radio polarization mounting direction is
correct.

Ceragon Proprietary and Confidential Page 69 of 94


FibeAir® RFU-C Installation Guide

For 1+1 Mounting:


Important! Do not remove the transparent pressure window located on
the antenna interface.
5 Mount the two O-Rings supplied in the Coupler kit and twist on the coupler
body, as defined in the Coupler kit instructions.
Note: For 15 GHz and 18 GHz, an EMI gasket (supplied with the
RFU-P interface) should be mounted between the twist and
the coupler body.

Ceragon Proprietary and Confidential Page 70 of 94


FibeAir® RFU-C Installation Guide

6 Mount the coupler on the RFU-P interface using the four M8 screws and
washers supplied in Coupler kit, and tighten the screws.
7 Proceed with mounting the RFUs, as defined in the Coupler kit
instructions.

Ceragon Proprietary and Confidential Page 71 of 94


FibeAir® RFU-C Installation Guide

For Remote Mounting:


8 Glue the gasket to the RFU-P interface plate with the sticky side facing the
plate. The gasket is supplied in the RFU-C/RFU-P Direct Mount Interface
Kit.
9 Connect the Flexible Wave-Guide using the four M3 screws and washers
supplied in the Coupler Kit, and tighten the screws.

Ceragon Proprietary and Confidential Page 72 of 94


FibeAir® RFU-C Installation Guide

9.3 Installing an RFU-C Adaptor to Ericsson Antennas


(RAU1 Radios)

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1
RFU-C — Ericsson Adaptor Kit for RAU1, in
2 1
accordance with BOM

Required Tools

 Automatic screwdriver with torque


 Bit screwdriver head adaptor
 Phillips screw head bits, size 2
 6.0 mm Offset hexagon key wrench

Procedure

Important: Do not remove the protective sticker from the radio.

9.3.1 Connecting the Adaptor Kit to the Ericsson Antenna


1 Before placing the coupling plate, verify that the O-Rings are placed
correctly in their sinks in the Ericsson antenna and in the interface on the
basic coupling plate.
2 Place the RFU-C-Ericsson Adapter Kit for RAU1 on the Ericsson antenna.
3 Tighten the three screws and spring washers supplied in the -C-Ericsson
Adapter Kit for RAU1, as shown in the figure below.

Ceragon Proprietary and Confidential Page 73 of 94


FibeAir® RFU-C Installation Guide

9.3.2 Connecting the RFU to the Ericsson Antenna


1 Mount the RFU to the antenna, using the four M8 captive screws and
washers supplied, assembled, in the RFU-C, and tighten the screws.
Make sure the polarization mounting direction of the RFU is correct.

Ceragon Proprietary and Confidential Page 74 of 94


FibeAir® RFU-C Installation Guide

9.4 Installing an RFU-C Adaptor to Ericsson 0.3m Compact


Antennas (RAU2 Radios)

List of Items

Item Description Quantity Remarks


1 RFU-C RADIO 1
RFU-C — Ericsson Adaptor Kit
2 for RAU2, in accordance with 1
BOM

Required Tools

 Automatic screwdriver with torque


 Bit screwdriver head adaptor
 Phillips screw head bits, size 2
 6.0 mm Offset hexagon key wrench

Procedure

Important: Do not remove the protective sticker from the radio.

9.4.1 Connecting the Adaptor Kit to the Ericsson 0.3m Compact


Antenna
1 Insert the two lower screws and two spring washers supplied in the
Ericsson kit, as shown in the figure below. Do not tighten them!

Ceragon Proprietary and Confidential Page 75 of 94


FibeAir® RFU-C Installation Guide

2 Before placing the coupling plate, verify that the O-Rings are placed
correctly in their sinks in the Ericsson antenna and in the interface on the
basic coupling plate.
3 Place the Ericsson Coupling Basic Configuration Plate with inserts on the
Ericsson antenna lower screws.
4 Insert the two upper screws and spring washers supplied in the Ericsson
kit, as shown in the figure below.

5 Tighten the four screws, as shown in the figure below.

Ceragon Proprietary and Confidential Page 76 of 94


FibeAir® RFU-C Installation Guide

9.4.2 Connecting the RFU to the Ericsson Antenna


1 Mount the RFU to the antenna, using the four M8 captive screws and
washers supplied, assembled, in the RFU-C, and tighten the screws.
Make sure the polarization mounting direction of the RFU is correct.

Ceragon Proprietary and Confidential Page 77 of 94


FibeAir® RFU-C Installation Guide

9.5 Installing an RFU-C – NEC Adapter (PASOLINK NEO)


Note: These instructions are relevant for antennas up to 4 feet.

List of Items

Item Description Quantity


1 RFU-C - NEC ADAPTOR PLATE 1
SCREW AND WASHER ASSEMBLY, SOCKET HEXAGON HEAD CAP,
2 WITH HELICAL WASHER, 4
SS, ~DIN 912-M6x16-A2-70 and ~DIN 127-B6-A2-70

Required Tools

 5 mm offset hexagon key wrench

Procedure

1 Make sure there are two O-Rings, one on the NEC antenna and one on the
RFU-C - NEC adapter plate.
2 Use the Location Pin (shown in the figures below) to guide the circular
part of the RFU-C - NEC adapter plate onto the circular part of the NEC
antenna.
3 Fasten the RFU-C - NEC adapter to the NEC Shenglu or Mobi antenna using
four screws and four washers.
Note: Fasten the screws diagonally. First fasten the upper right
screw and lower left screw, and then fasten the upper left
screw and lower right screw.

Ceragon Proprietary and Confidential Page 78 of 94


FibeAir® RFU-C Installation Guide

Attaching the Adapter Plate to an NEC Shenglu Antenna

Attaching the Adapter Plate to an NEC Mobi Antenna

Ceragon Proprietary and Confidential Page 79 of 94


FibeAir® RFU-C Installation Guide

4 Fasten the RFU-C to the RFU-C - NEC antenna adapter using four screws
and four washers.
Note: Make sure the polarization is correct, as shown in the figure
below.

5 Attach the RFU-C to the RFU-C - NEC adaptor by closing the four captive
screws and four washers that are supplied, assembled, in the RFU-C, and
tighten the screws.
Note: Make sure the polarization is correct, as shown in the
figures below.
Attaching the RFU-C to the RFU-C – NEC Adapter – Shenglu Antenna

Ceragon Proprietary and Confidential Page 80 of 94


FibeAir® RFU-C Installation Guide

Attaching the RFU-C to the RFU-C – NEC Adapter – Mobi Antenna

The figure below shows the RFU-C with the NEC adapter installed (Shenglu
antenna option).

Ceragon Proprietary and Confidential Page 81 of 94


FibeAir® RFU-C Installation Guide

9.6 Installing an RFU-C – SRAL Adaptor

List of Items

Item Description Quantity


1 RFU-C RADIO 1

RFU-C - SRAL Adapter Kit, as follows:


2  ADPT_RFU-C38-SRAL_ANT for 38 GHz (UBR320) 1
 ADPT_RFU-C18_26-SRAL_ANT for 18-26 GHz (UBR220)

Required Tools

 Automatic screwdriver with torque


 Bit screwdriver head adaptor
 Phillips screw head bits, size 2
 6.0 mm offset hexagon key wrench

Procedure

1 Place the RFU-C on the antenna adapter, aligning the holes at the four
corners of the two units.
Note: Make sure you align the units properly for the horizontal or
vertical direction. The letters H and V appear on both units,
for correct alignment.
2 Make sure the adapter O-ring is in place, as shown in the figure below.
3 Attach the RFU-C to the adaptor by closing the four captive screws and four
washers that are supplied, assembled, in the RFU-C, and tighten the screws.

Ceragon Proprietary and Confidential Page 82 of 94


FibeAir® RFU-C Installation Guide

4 Make sure the two antenna O-Rings (one smaller, the other larger) are in
their respective grooves on the antenna.
5 Place the RFU-C fastened to the adapter on the antenna, aligning them with
the two antenna location pins.
Note: Make sure you align the units properly for the horizontal or
vertical direction.

6 Fasten the RFU-C and the adapter to the SRAL antenna using the four
latches.

Ceragon Proprietary and Confidential Page 83 of 94


FibeAir® RFU-C Installation Guide

The figure below shows the RFU-C with the SRAL adapter installed.

Ceragon Proprietary and Confidential Page 84 of 94


FibeAir® RFU-C Installation Guide

9.7 Installing an ALU Melody Adapter

List of Items

Item Description Quantity


1 RFU-C Radio 1
RFU-C - ALU Adapter Kit, as follows:
2 ADPT_RFU-C18-ALU_Melody for 18-26 GHz (UBR220) 1
ADPT_RFU-C13-ALU_Melody for 13 GHz (UBR120)

Required Tools

 Automatic screwdriver with torque


 Bit screwdriver head adaptor
 Phillips screw head bits, size 2
 6.0 mm Offset Hexagon Key Wrench

Procedure

1 Place the O-ring (supplied with RFU-C ALU Adapter kit) at the center of the
transition, so the flat area is facing towards the tube.

Ceragon Proprietary and Confidential Page 85 of 94


FibeAir® RFU-C Installation Guide

2 Verify the alignment of polarization between the antenna and the RFU-C
ALU Adapter kit. If they are not aligned, release the four screws of RFU-C
ALU Transition, rotate the RFU-C ALU Transition by 90 degrees, and re-
tighten the screws.

3 Place the RFU-C Radio on the RFU-C ALU Adapter Kit according to the
correct polarization and secure with the four screws and washers
(included in the RFU-C Radio kit).

Ceragon Proprietary and Confidential Page 86 of 94


FibeAir® RFU-C Installation Guide

4 Verify the presence of the antenna O-Ring on ALU Antenna before


mounting the RFU-C ALU Adapter kit (this O-Ring is part of the ALU
antenna).

5 Gently place the RFU-C ALU Adapter kit on the ALU Antenna tube's feeder,
using the slots to center the RFU-C ALU Adapter Kit with the ALU antenna.
Note: Make sure the units are properly aligned with horizontal or
vertical polarization.

Ceragon Proprietary and Confidential Page 87 of 94


FibeAir® RFU-C Installation Guide

6 Latch the RFU-C ALU Adapter kit to the ALU antenna using the four latches.
It is highly recommended to secure at least one of the latches with a lock.

Ceragon Proprietary and Confidential Page 88 of 94


FibeAir® RFU-C Installation Guide

9.8 Converting from Nera ODU to RFU-C


If you need to replace a Nera ODU with an RFU-C, you must replace the
adaptor for the ValuLine antenna. The following are instructions for installing
the new Andrews adapter.
This integration assembly used in conjunction with the feed assembly is
designed to be mounted into the reflector of a 2ft (0.6m), 3ft (0.9m), 4ft (1.2m)
or 6ft (1.8m) antenna.

Notice

The installation, maintenance, or removal of antenna systems requires


qualified, experienced personnel. Andrew installation instructions have been
written for such personnel. Antenna systems should be inspected once a year
by qualified personnel to verify proper installation, maintenance, and
condition of equipment.
Ceragon disclaims any liability or responsibility for the results of improper or
unsafe installation practices.

Use protective wear to avoid skin contact with the compound. Keep away
from mouth. Wash thoroughly after use with liberal amounts of liquid soup
and rinse with water. Do not store open near food or food sources. Contents:
WARNING!
Oil, Clay, and Zinc Dust.

List of Items

List of Items (10-42 GHz) List of Items (6-7 GHz)

Item Description Qty Item Description Qty


1 Interface Plate 1 1 Interface Plate 1
2 O-Ring (2 & 3 ft ONLY) 1 2 O-Ring (2 & 3 ft ONLY) 1

3 Transition 1 3 Transition 1
4 M8 Skt Hd Cs'k Screw 16lg 8 4 M8 Skt Hd Cs'k Screw 16lg 2
5 Silicon Grease (tube) 1 5 M8 Skt Hd Cs'k Screw 55lg 6
6 Conductive Grease (tube) 1 6 Silicon Grease (tube) 1
7 O-Ring 1 7 Conductive Grease (tube) 1
8 O-Ring 1

Ceragon Proprietary and Confidential Page 89 of 94


FibeAir® RFU-C Installation Guide

Procedure

1 Fit the interface plate to the hub mounting ring using six of the c'sk screws
that are supplied.
i Make sure that the interface plate has been properly located before
tightening to a torque of 10Nm±5%. Refer to Step 6 for polarization
settings.
ii Make sure that the timing pin is located in the timing recess in the
interface plate.

2 Remove the protective tape.


3 Assemble the small o-ring to feed.
4 Smear a small amount of silicon grease onto the O-Ring (two and three feet
ONLY).

Ceragon Proprietary and Confidential Page 90 of 94


FibeAir® RFU-C Installation Guide

5 To assemble the transition hub, orient the hub as shown above and fasten
two of the c'sk screws that are supplied in line with the scalloped edges, as
shown above, to a torque of 10Nm±5%.
6 Set the polarization:
Vertically Polarized Application
i Align the Polarization indicator on the transition assembly with the “V”
timing mark on the interface plate.

ii Loosen the two c'sk screws two places until the transition assembly
can rotate freely.
iii Rotate the transition assembly until the timing pin is located in the
timing recess of the interface plate at the “V” position.
iv Re-tighten the c’sk screws to a torque of 10Nm±5%.

Ceragon Proprietary and Confidential Page 91 of 94


FibeAir® RFU-C Installation Guide

Horizontally Polarized Application


i Align the Polarization indicator on the transition assembly with the “H”
timing mark on the interface plate.

ii Loosen the two c'sk screws two places until the transition assembly
can rotate freely.
iii Rotate the transition assembly until the timing pin is located in the
timing recess of the interface plate at the “H” position.
iv Re-tighten the c’sk screws to a torque of 10Nm±5%.
View Showing Full Assembly of Interface Plate and Transition Hub to Reflector

Ceragon Proprietary and Confidential Page 92 of 94


FibeAir® RFU-C Installation Guide

10. Appendix A: Mediation Device Losses


RFU-C Mediation Device Losses

13-15 18-26 28-42


Configuration Interfaces 6-8 GHz 11 GHz
GHz GHz GHz
Remote Mount Added on remote
Flex WG 0.5 0.5 1.2 1.5 1.5
antenna mount configurations
1+0 DirectMount Integrated antenna 0.2 0.2 0.4 0.5 0.5
1+1 HSB Main Path 1.6 1.6 1.8 2 2
Direct Mount
with asymmetrical coupler Secondary Path 6 6 6 6 6
1+1 HSB Main Path 1.4 1.4 1.6 1.8 1.8
Remote Mount
with asymmetrical coupler Secondary Path 6 6 6 6 6
2+0 DP (OMT) Direct Mount Integrated antenna 0.5 0.5 0.5 0.5 0.5
2+2 HSB (OMT) Main Path 1.9 1.9 2.1 2.3 2.3
Remote Mount
with asymmetrical coupler Secondary Path 6.5 6.5 6.5 6.5 6.5
2+0/1+1 FD SP Integrated antenna 3.8 3.8 3.9 4 4
4+0 DP (OMT) Remote Mount 4.2 4.2 4.3 4.4 4.4

Notes: The antenna interface is always the RFU-C interface.


If other antennas are to be used, an adaptor with a 0.1 dB
loss should be considered.
Loss (dB)
Item
6-8 GHz 11 GHz 13-15 GHz 18-32 GHz 38 – 42 GHz
Flexible Waveguide 0.5 0.5 1.2 1.5 1.5
Main Coupler 1.4 1.4 1.4 1.5 1.5
Secondary Coupler 6 6 6 6 6
Twist 0 0 0 0 0

Note: The numbers above are typical losses per component.

Ceragon Proprietary and Confidential Page 93 of 94


FibeAir® RFU-C Installation Guide

11. Appendix B: Test Kit Part Numbers

Band 1+0 1+1 XPIC


6 GHz RFU-C6-TS/NP RFU-C6-TS/P RFU-C6-TS/X
7/8 GHz RFU-C7_8-TS/NP RFU-C7_8-TS/P RFU-C7_8-TS/X
10/11 GHz RFU-C10_11-TS/NP RFU-C10_11-TS/P RFU-C10_11-TS/X
13 GHz RFU-C13-TS/NP RFU-C13-TS/P RFU-C13-TS/X
15 GHz RFU-C15-TS/NP RFU-C15-TS/P RFU-C15-TS/X
18-26 GHz RFU-C18_26-TS/NP RFU-C18_26-TS/P RFU-C18_26-TS/X
28-38 GHz RFU-C28_38-TS/NP RFU-C28_38-TS/P RFU-C28_38-TS/X
42 GHz RFU-C42-TS/NP RFU-C42-TS/P RFU-C42-TS/X