VRV 3 - S - 0 PDF
VRV 3 - S - 0 PDF
VRV 3 - S - 0 PDF
S
The VRVIII-S is highly space saving, featuring slim and compact
outdoor units. It is suitable for small offices and shops with capacities
of 4, 5 and 6 HP.
765 mm
320 mm
5S
concept Space saving
Sufficient capacity
Slim design
Sound-reduced operation
E
Single phase power supply
Outdoor unit can be installed
on a balcony
Easy installation
1E
The compact, trunk-shaped outdoor unit can easily
be installed on a balcony, realising complete system
installation within each floor. This enables more
concept useful utilisation of the space on the building rooftop.
Contents
Introduction.......... page 1 Indoor unit lineup..... page 15 Option list............ page 33
Indoor units......... page 33
Main features........ page 3 Specifications........... page 25 Outdoor units.......page 35
Indoor units............... page 25 Control systems...page 35
1
Control systems... page 9 Outdoor units............ page 32 2
MAIN FEATURES
Wide range of choices
To suit the variety of rooms found in small offices
Indoor units
and shops, the VRVIII-S system offers wide range of 14 types 71 models*
indoor and outdoor units. A wide range of indoor units includes
VRVIII-S indoor and outdoor units are almost as easy 71 models in 14 types. The indoor
to install as residential air conditioning systems, units can be selected to match every
making them ideal for small offices and shops. room and preference.
Outdoor units
3 models
Outdoor unit can be selected from three
models to provide the power that suits
your needs. The trunk-shaped outdoor unit
can be neatly installed outside the office.
Indoor unit lineup 14 types 71 models*
Outdoor unit lineup Type Model Name 20 25 32 40 50 63 80 100 125 140
Model Name RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 6 HP
Capacity Index 20 25 31.25 40 50 62.5 80 100 125 140
Capacity Range 4 HP (11.2 kW) 5 HP (14.0 kW) 6 HP (15.5 kW) Ceiling Mounted FXFQ-LU
Cassette
(Round Flow)
Capacity Index 100 125 140 Ceiling Mounted FXZQ-MVE
Cassette
(Compact Multi Flow)
Ceiling Mounted FXCQ-MVE
Cassette
(Double Flow)
Ceiling Mounted FXKQ-MAVE
Cassette Corner
FXDQ-PBVE
(with drain pump)
Slim Ceiling
Mounted Duct FXDQ-NBVE
(with drain pump)
Concealed FXNQ-MAVE
Floor Standing
Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.
Note: BEV units are necessary for Connection unit series indoor units.
3 4
MAIN FEATURES
Energy efficiency and quiet operation A collection of cutting-edge technologies
Outdoor units use Daikin’s unique scroll compressor to realise energy saving
realises efficient and quiet operation.
performance and quiet operation. The high efficiency compressor to achieve a higher COP
1 Compressor equipped with Reluctance DC motor 3
High COP
Daikin DC inverter models are equipped with the Reluctance DC
High COP during both cooling and achieved
in all ranges! motor for compressor. The Reluctance DC motor uses 2 different 2
compressor. 5 HP 3.41
70 More than 20% RX(Y)MQ4PVE
RX(Y)MQ5PVE
RX(Y)MQ6PVE
6 HP 3.19 60 AC motor
Quiet operation provides Note: Data are based on studies conducted under
luxurious comfort Lower operation sound is achieved controlled conditions at a Daikin laboratory
using Daikin products.
in cooling operation! 1 dB(A) reduced
*1 A neodymium magnet is approximately 10 times
Quietness is yet another important feature in each model! stronger than a standard ferrite magnet.
VRVII-S *2 The torque created by the change in power
of Daikin’s VRVIII-S system. To reduce Previous model
RXYM-MVM between the iron and magnet parts.
noise and realise comfortable operation,
latest technologies and features are Cooling 4 HP 51 -1dB(A) 50
>> Smooth sine wave DC inverter
52
Sine wave DC inverter
applied to the outdoor units. 5 HP -1dB(A) 51 Use of an optimised sine wave smoothes motor rotation, further improving
operating efficiency.
level for the night mode can be selected from 47 dB(A) 50 Escaping eddies are sucked in by
(Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3). the bent blade edges, reducing
overall turbulence.
Efficiency (%)
Step 3 max. - 9 dB(A) Approx.
Step 3: 41 dB(A)
Mode 3. Combined mode ( 4 HP/11.2 kW) DC fan motor structure 60 20%
41 increase
Combinations of modes 1 and 2 can be used Night mode starts Night mode ends 40 Approx.
depending on your needs. 8:00 12:00 16:00 20:00 0:00 4:00 8:00 40% AC motor
Note: Data are based on
*1. Initial setting. Can be selected from 6, 8 and 10 hours. Note: • This function is available in setting at site. 20 increase
studies conducted under
*2. Initial setting. Can be selected from 8, 9 and 10 hours. • The relationship of outdoor temperature (load) and time shown in the 0 controlled conditions at
graph is just an example.
200 300 400 500 600 700 800 900 1000 a Daikin laboratory.
The capacity reduction rate differs depending on the operation sound level
step selected.
Motor speed (rpm)
5 6
MAIN FEATURES
Design flexibility Easy installation
VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and A variety of functions are provided that make installation easier, such as simple wiring
multiple indoor unit combinations, which provides generous freedom for office and shop and piping and automatic test operation.
design both inside and out. Previous model
VRVII-S
For a 6 HP installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check,
1 2 3 4
Max.
including wiring, shutoff valves, and sensors. The results are returned automatically after the
9 units
check finishes.
>> Max. 8 indoor units for a 5 HP
installation
5 6 7 8 9
>> Max. 6 indoor units for a 4 HP
installation
Simple wiring and piping connection
Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily.
7 8
CONTROL SYSTEMS
Control systems
The VRVIII-S system uses the same DIII-NET communication system as the
VRV, enabling the use of advanced control systems.
Wired remote controller (Option) Wired remote controller Wireless remote Signal receiver unit
(Installed type)
controller
Simplified(Option)
The remote controller has
centralised its frequently used
operation selectors and switches
(on/off, operation mode,
temperature setting and airflow
volume), making itself suitable
for use in hotel rooms or
conference rooms.
The exposed type remote
BRC1D61 controller is fitted with a
BRC1C62 Concealed type
Notes: 1. Standard remote controllers (BRC1C62) not required. (For hotel use) thermostat sensor.
2. If the BRC1D61 is connected to the centralised remote controllers (BRC3A61)
(DCS303A51, DCS302CA61, DCS301BA61, DST301BA61), the
schedule function is not available. Exposed type
(BRC2C51) The concealed type remote controller smartly fits into a
night table or console panel in a hotel room.
The wired remote controller supports a wide range of control functions
Control of Cool/Heat In all the series of VRV, Cool/Heat changeover in the same refrigerant Wide variation of remote controllers for indoor units
changeover circuit can be changed by the remote controller of the indoor unit. 1 Control by two remote controller
The indoor unit can be connected by the two FXFQ FXZQ FXCQ FXKQ FXDQ FXMQ FXHQ FXAQ FXL(N)Q FXUQ
remote controller, for example one in the room
Group control and the other one in the control room, which Navigation remote controller
Equipment One remote controller can can control the operation of indoor unit freely. (Wired remote controller)
Outdoor control the operation of max.16 (BRC1E61)
unit related to the (The last command has a priority.) Of course,
central control indoor units at the same time.
the group control by two remote controller is
also possible. Wired remote controller
(BRC1C62)
2 Remote control
Remote controller
Indoor unit Wired remote controller with
The wiring of remote controller can be
Remote controller weekly schedule timer
extended to max. 500 m and it is possible (BRC1D61)
to install the remote controllers for the
different indoor units in one place.
Wireless remote controller*
(Installed type
Remote
controller 3 Control for the combined operation
The operation of Heat Reclaim Ventilator
Forced OFF be controlled by the remote controller of the Wireless remote controller*
input (Separate type signal receiver unit)
indoor unit. Of course, the remote controller
can display the time to clean the filter.
Heat Reclaim
Ventilator
Remote
Simplifiedremote controller
Remote controller controller Remote controller (Exposed type)
Remote controller Remote controller 4 Expansion of system control (BRC2C51)
9 Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. *Refer to page 35 for the name of each model. 10
CONTROL SYSTEMS
Centralised control systems
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Residential central remote controller* (Option)
Optional controllers for centralised control can be combined and optimised in Max. 16 groups of indoor units can be easily controlled with
accordance with building scale and purpose. the large LCD panel.
Max. 16 groups (128 indoor units) controllable
System integration with various air-conditioning peripheral equipment such as Backlight and large LCD panel for easy readability
ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.
Heat Reclaim Ventilator is easy. All indoor units can be turned on or off at once with “ALL” button.
Each group has a dedicated button for convenience.
Wiring can be run up to a total length of 2 km, and adapts easily to large-scale DCS303A51
Outside temperature display
*For residential use only. Cannot be used with other centralised control equipment.
system expansion.
11 12
CONTROL SYSTEMS
Advanced control systems
New
One touch selection to total air comfort Communication functions in the user-friendly icon-based multilingual controller simplify
centralised control of the VRV system.
Daikin proudly introduces its new intelligent Touch Manager, a VRV system controller
featuring an array of simple, useful system management functions for added value.
system overview
Up to 2,560 groups (5,120 indoor units) can be controlled by one system
Dio Unit Di Unit
DEC102A51 DEC101A51
system overview (Option) (Option)
Internet
Intranet LAN iTM plus adaptor line iTM plus adaptor (Max. 7 adaptors)
Max. 50m
Web Access
Lighting Pump Fan Sensor
Features Features
✫ Central control
• Handy area settings simplify detailed management of VRV. Colour LCD touch panel icon display
• Display of floor plans enables a quick search of desired air conditioning units.
• Operation history shows manner of control and origin in past operations of air conditioning units. Small manageable size
✫ Remote access
• Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the Simplified engineering
intelligent Touch Manager.
Multi language (English, French, Italian, German,
• Authorised users can centrally control individual air conditioning units from their own computers.
✫ Automatic control Spanish, Dutch, Portuguese, Chinese and Korean)
• VRVs are controlled automatically throughout the year by the schedule function.
• Interlocking VRVs and other equipment enables easy automation of building facilities operation. Yearly schedule
• Setback adjusts temperature settings even when rooms are unoccupied.
✫ Energy management
Auto heat/cool change-over
• The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient Temperature limitation
operation.
✫ Troubleshooting Enhanced history function
• Contact information of maintenance contractors can be registered and displayed.
• E-mails are sent automatically to alert of malfunctions and potential trouble. Simple Interlock Function
• The intelligent Touch Manager can link to the Air Conditioning Network Service System for 24-hour monitoring of operating Built-in modem for connecting to Air Conditioning Network Service System (Option)
conditions and status.
✫ Scalability Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)
• A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings.
• Large building properties can also take advantage of the iTM integrator to link up and expand system up to 5 intelligent Touch Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)
Managers for integrated control.
13 14
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Round Flow) Type (Compact Multi Flow) Type
FXFQ25L/FXFQ32L/FXFQ40L
FXZQ20M/ FXZQ25M
FXFQ50L/FXFQ63L/FXFQ80L FXZQ32M/FXZQ40M
FXFQ100L/FXFQ125L FXZQ50M
FXZQ-M 20/25 32 40 50
been applied, with a panel surface that has been has been applied to the drain pan, preventing Angles can be also set on site to prevent drafts (0-35)
or soiling of the ceiling (25-60), other than standard setting (0-60).
treated with a dirt-repellant coating. the growth of slime, mould and bacteria that
Treated surface Untreated surface
cause blockages and odours.
Dirt and
2 2-, 3-, and 4-way airflow patterns are available,
Resists grime • Condition after
exposure to the The horizontal louvres prevent dew enabling installation in the corner of a room.
soiling
smoke of 600
condensation. Their non-flocking surfaces, which
Drain pump is equipped as standard
3
cigarettes in 1 m
enclosed space.
repel dirt, are easy to clean.
Control of the airflow rate has been improved accessory with 750 mm lift.
from 2-step to 3-step control.
The air filter has an anti-mould and antibacterial
Low operation sound level (dB(A)) treatment that prevents the growth of mould
FXFQ-L
Sound
25/32 40 50 63 80 100 125
generated from dust or moisture that may L-shaped 750 mm
level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 adhere to the filter. 4-way flow 3-way flow 2-way flow
(HH/H/L)
For 3-way or 2-way flow installation, the sealing member for air discharge
All-round flow 4-way flow 3-way flow L-shaped 2-way flow outlet (option) must be used to close each unused outlet.
Example of airflow patterns:
360 airflow is available, as well as 2- to
4-way flows, so you can choose the most
suitable airflow pattern depending on
location or room layout.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.
15 16
INDOOR UNIT LINEUP
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Double Flow) Type Corner Type
FXCQ20M/FXCQ25M/FXCQ32M FXKQ25MA /FXKQ32MA
FXCQ40M/ FXCQ50M/ FXCQ63M FXKQ40MA /FXKQ63MA
FXCQ80M/FXCQ125M
and a detachable blade make cleaning easy. A long-life filter (maintenance free up to one
year ) is equipped as standard accessory.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
17 18
INDOOR UNIT LINEUP
Slim Ceiling Mounted Ceiling Mounted
Duct Type Duct Type
FXMQ20P/FXMQ25P/ FXMQ32P
Slim design, quietness and FXMQ40P/FXMQ50P/ FXMQ63P
FXMQ80P/FXMQ100P/ FXMQ125P
static pressure switching FXMQ140P
19 20
INDOOR UNIT LINEUP
Ceiling Suspended Type Wall Mounted Type
FXAQ20P/FXAQ25P
FXHQ32MA/FXHQ63MA New FXAQ32P/FXAQ40P
FXHQ100MA
FXAQ50P/FXAQ63P
Turbulent flow
is produced
Quiet stream fan
Low operation sound level (dB(A))
Straightening vane
FXAQ-P 20 25 32 40 50 63
Sound level
(H/L) 35/31 36/31 38/31 39/34 42/37 47/41
Low operation sound level (dB(A))
FXHQ-MA 32 63 100
Sound level 36/31 39/34 45/37 Drain pan and air filter can be kept clean by
(H/L) mould-proof polystyrene.
Installation is easy
Vertical auto-swing realises efficiency of air
Drain pump kit (option) can be easily
distribution. The louvre closes automatically
incorporated.
when the unit stops.
600 mm
21 22
INDOOR UNIT LINEUP
Connection unit series indoor units
Concealed Floor
Standing Type Only one unit is needed to distribute comfortable air
throughout an L-shaped store.
FXNQ20MA/ FXNQ25MA
FXNQ32MA/ FXNQ40MA
FXNQ50MA/ FXNQ63MA
Designed to be concealed in the perimeter skirting-wall Connection unit Connection unit is the device for connecting above indoor unit to VRVIII-S.
BEVQ71MA/BEVQ100MA/BEVQ125MA
The unit is concealed in skirting-wall of perimeter, that enables
Refrigerant piping layout External wiring layout
to create high class interior design. *1 Maximum piping length
Connection unit for indoor unit Model between the BEV unit
and the indoor unit.
23 24
SPECIFICATIONS
INDOOR UNITS Ceiling Mounted Cassette (Double Flow) Type
MODEL FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
Ceiling Mounted Cassette (Round Flow) Type Power supply 1-phase, 220 - 240 V/220 V, 50 Hz
MODEL FXFQ25LU FXFQ32LU FXFQ40LU FXFQ50LU FXFQ63LU FXFQ80LU FXFQ100LU FXFQ125LU kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 6,300 8,000 12,500
Btu/h(*1) 7,800 9,900 12,600 16,000 19,800 24,900 31,700 49,500
Power supply 1-phase, 220 -240 V/220 V, 50 Hz Cooling capacity
kW (*1) 2.3 2.9 3.7 4.7 5.8 7.3 9.3 14.5
kcal/h(*1) 2,500 3,200 4,000 5,000 6,300 8,000 10,000 12,500
(*2) 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
Btu/h(*1) 9,900 12,600 16,000 19,800 24,900 31,700 39,600 49,500
Cooling capacity Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900 8,600 13,800
kW (*1) 2.9 3.7 4.7 5.8 7.3 9.3 11.6 14.5
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 34,100 54,600
(*2) 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0
Heating capacity kcal/h 2,800 3,400 4,300 5,400 6,900 8,600 10,800 13,800
Casing Galvanised steel plate
Btu/h 10,900 13,600 17,100 21,500 27,300 34,100 42,700 54,600
Airflow rate (H/L) m3/min 7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25
kW 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
cfm 247/177 318/230 318/230 424/318 424/318 582/459 918/741 1,165/883
Casing Galvanised steel plate
Sound level (H/L) 220 V dB(A) 32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38
Airflow rate (HH/H/L) m3/min 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5
240 V 34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
cfm 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794
Dimensions (HXWXD) mm 305X775X600 305X775X600 305X775X600 305X990X600 305X990X600 305X1,175X600 305X1,665X600 305X1,665X600
Sound level (HH/H/L) dB(A) 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
Machine weight kg 26 26 26 31 32 35 47 48
Dimensions (HXWXD) mm 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5
Machine weight kg 19.5 19.5 19.5 19.5 22 22 25 25 Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9
Liquid (Flare) mm 6.4 6.4 6.4 6.4 9.5 9.5 9.5 9.5
Drain VP25 (External Dia, 32/Internal Dia, 25)
Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9
Model BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1
Drain VP25 (External Dia, 32/Internal Dia, 25)
Panel Colour White (10Y9/0.5)
Model BYCP125K-W1 (Option)
Dimensions (HXWXD) mm 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680
Panel Colour Fresh white
Weight kg 8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0
(Option)
Dimensions (HXWXD) mm 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950
Weight kg 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Ceiling Mounted Cassette Corner Type
Ceiling Mounted Cassette (Compact Multi Flow) Type MODEL FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE
MODEL FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Power supply 1-phase, 220- 240 V/220 V, 50 Hz
Power supply 1-phase, 220-240 V/220 V, 50 Hz kcal/h(*1) 2,500 3,200 4,000 6,300
Btu/h(*1) 9,900 12,600 16,000 24,900
kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 Cooling capacity
kW (*1) 2.9 3.7 4.7 7.3
Btu/h(*1) 7,800 9,900 12,600 16,000 19,800
Cooling capacity (*2) 2.8 3.6 4.5 7.1
kW (*1) 2.3 2.9 3.7 4.7 5.8
Heating capacity kcal/h 2,800 3,400 4,300 6,900
(*2) 2.2 2.8 3.6 4.5 5.6
Btu/h 10,900 13,600 17,100 27,300
Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400
kW 3.2 4.0 5.0 8.0
Btu/h 8,500 10,900 13,600 17,100 21,500
Casing Galvanised steel plate
kW 2.5 3.2 4.0 5.0 6.3 Airflow rate (H/L) 50 Hz m3/min 11/9 11/9 13/10 18/15
Casing Galvanised steel plate cfm 388/318 388/318 459/353 635/530
Airflow rate (H/L) m3/min 9/7 9/7 9.5/7.5 11/8 14/10 Sound level (H/L) 220 V dB(A) 38/33 38/33 40/34 42/37
cfm 318/247 318/247 335/265 388/282 493/353 240 V 40/35 40/35 42/36 44/39
dB(A) Dimensions (HXWXD) mm 215X1,110X710 215X1,110X710 215X1,110X710 215X1,310X710
Sound level 30/25-32/26-32/29 30/25-32/26-32/29 32/26-34/28-33/29 36/28-37/29-36/30 41/33-42/35-41/34
(H/L) 230 V, 50 Hz-240 V, Machine weight kg 31 31 31 34
50 Hz-220 V,
Liquid (Flare) mm 6.4 6.4 6.4 9.5
Dimensions (HXWXD) mm 286X575X575 Piping
connections Gas (Flare) 12.7 12.7 12.7 15.9
Machine weight kg 18 Drain VP25 (External Dia, 32/Internal Dia, 25)
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 Model BYK45FJW1 BYK71FJW1
Piping Colour White (10Y9/0.5)
Panel
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7
(Option) Dimensions (HXWXD) mm 70X1,240X800 70X1,240X800 70X1,240X800 70X1,440X800
Drain VP20 (External Dia, 26/Internal Dia, 20)
Weight kg 8.5 8.5 8.5 9.5
Model BYFQ60B8W1
Note: Specifications are based on the following conditions;
Panel Colour White (6.5Y9.5/0.5)
•Cooling: Indoor temp.: (*1)27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2)27CDB, 19CWB, Outdoor
(Option) temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping
Dimensions (HXWXD) mm 55X700X700 55X700X700 55X700X700 55X700X700 55X700X700
length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. Sound
Weight kg 2.7 2.7 2.7 2.7 2.7 level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally
somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: (*1)27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. (*2)27CDB, 19CWB,
Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent
piping length: 7.5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity
index. Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these
values are normally somewhat higher as a result of ambient conditions.
25 26
SPECIFICATIONS
Slim Ceiling Mounted Duct Type (700 mm width type) Ceiling Mounted Duct Type
MODEL with
drain pump FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE MODEL FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE
Power supply 1-phase, 220-240 V/220 V, 50 Hz Power supply 1-phase, 220-240 V/220 V, 50 Hz
kcal/h(*1) 2,000 2,500 3,200 kcal/h(*1) 2,000 2,500 3,200 4,000 5,000
Btu/h(*1) 7,800 9,900 12,600 Btu/h(*1) 7,800 9,900 12,600 16,000 19,800
Cooling capacity Cooling capacity
(*1) 2.3 2.9 3.7 (*1) 2.3 2.9 3.7 4.7 5.8
kW kW
(*2) 2.2 2.8 3.6 (*2) 2.2 2.8 3.6 4.5 5.6
kcal/h 2,200 2,800 3,400 kcal/h 2,200 2,800 3,400 4,300 5,400
Heating capacity Btu/h 8,500 10,900 13,600 Heating capacity Btu/h 8,500 10,900 13,600 17,100 21,500
m3/min 8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4 m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11 18/16.5/15
Airflow rate (HH/H/L) Airflow rate (HH/H/L)
cfm 282/254/226 282/254/226 282/254/226 cfm 318/265/230 318/265/230 335/282/247 565/459/388 635/582/530
1 1 1 1 1
External static pressure Pa 30-10 1 External static pressure Pa 30-100 30-100 30-100 30-160 50-200
Sound level (HH/H/L) 2 3 dB(A) 33/31/29 33/31/29 33/31/29 Sound level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35 41/39/37
Dimensions (HXWXD) mm 200X700X620 200X700X620 200X700X620 Dimensions (HXWXD) mm 300X550X700 300X550X700 300X550X700 300X700X700 300X1,000X700
Liquid (Flare) 6.4 6.4 6.4 Liquid (Flare) 6.4 6.4 6.4 6.4 6.4
Piping Piping
mm connections Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7
connections Gas (Flare) 12.7 12.7 12.7
Drain VP20 (External Dia, 26/Internal Dia, 20) Drain VP25 (External Dia, 32/Internal Dia, 25)
Slim Ceiling Mounted Duct Type (900/1,100 mm width type) MODEL FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE
with Power supply 1-phase, 220-240 V/220 V, 50 Hz
MODEL drain pump FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
kcal/h(*1) 6,300 8,000 10,000 12,500 14,300
Power supply 1-phase, 220-240 V/220 V, 50 Hz
Btu/h(*1) 24,900 31,700 39,600 49,500 57,000
kcal/h(*1) 4,000 5,000 6,300 Cooling capacity
(*1) 7.3 9.3 11.6 14.5 16.7
Btu/h(*1) 16,000 19,800 24,900 kW
Cooling capacity (*2) 7.1 9.0 11.2 14.0 16.0
(*1) 4.7 5.8 7.3
kW kcal/h 6,900 8,600 10,800 13,800 15,500
(*2) 4.5 5.6 7.1
Heating capacity Btu/h 27,300 34,100 42,700 54,600 61,400
kcal/h 4,300 5,400 6,900
kW 8.0 10.0 12.5 16.0 18.0
Heating capacity Btu/h 17,100 21,500 27,300
Casing Galvanised steel plate
kW 5.0 6.3 8.0
m3/min 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
Casing Galvanised steel plate Airflow rate (HH/H/L)
cfm 688/618/565 883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130
m3/min 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0
Airflow rate (HH/H/L) 1 1 1 1 1
External static pressure Pa 50-200 50-200 50-200 50-200 50-140
cfm 371/335/300 441/388/353 583/512/459
Sound level (HH/H/L) dB(A) 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
External static pressure Pa 44-15 1
Dimensions (HXWXD) mm 300X1,000X700 300X1,000X700 300X1,400X700 300X1,400X700 300X1,400X700
Sound level (HH/H/L) 2 3 dB(A) 34/32/30 35/33/31 36/34/32
Machine weight kg 36 36 46 46 47
Dimensions (HXWXD) mm 200X900X620 200X900X620 200X1,100X620
Liquid (Flare) 9.5 9.5 9.5 9.5 9.5
Machine weight kg 27 28 31 Piping
mm
Liquid (Flare) 6.4 6.4 9.5 connections Gas (Flare) 15.9 15.9 15.9 15.9 15.9
Piping Drain VP25 (External Dia, 32/Internal Dia, 25)
mm
connections Gas (Flare) 12.7 12.7 15.9
Note: Specifications are based on the following conditions;
Drain VP20 (External Dia, 26/Internal Dia, 20) •Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Note: Specifications are based on the following conditions;
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Cooling: Indoor temp.: (*1) 27CDB, 19.5CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(*2) 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
•Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.
1: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for
FXDQ-PB models and 15 Pa for FXDQ-NB models.)
2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).
3: Values are based on the following conditions: FXDQ-PB external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
27 28
SPECIFICATIONS
Ceiling Suspended Type Floor Standing Type/Concealed Floor Standing Type
MODEL FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE
Power supply 1-phase, 220-240 V/220 V, 50 Hz FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
kcal/h(*1) 3,200 6,300 10,000 Power supply 1-phase, 220 - 240 V/220 V, 50 Hz
Btu/h(*1) 12,600 24,900 39,600 kcal/h(*1) 2,000 2,500 3,200 4,000 5,000 6,300
Cooling capacity
kW (*1) 3.7 7.3 11.6 FXLQ Btu/h(*1) 7,800 9,900 12,600 16,000 19,800 24,900
Cooling capacity
(*2) 3.6 7.1 11.2 kW (*1) 2.3 2.9 3.7 4.7 5.8 7.3
Heating capacity kcal/h 3,400 6,900 10,800 (*2) 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 13,600 27,300 42,700 Heating capacity kcal/h 2,200 2,800 3,400 4,300 5,400 6,900
kW 4.0 8.0 12.5 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Casing White (10Y9/0.5) kW 2.5 3.2 4.0 5.0 6.3 8.0
m3/min 12/10 17.5/14 25/19.5 Casing FXLQ: Ivory white (5Y7.5/1) / FXNQ: Galvanised steel plate
Airflow rate (H/L) FXNQ
cfm 424/353 618/494 883/688 Airflow rate (H/L) m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12
Sound level (H/L) dB(A) 36/31 39/34 45/37 cfm 247/212 247/212 282/212 388/300 494/388 565/424
Dimensions (HXWXD) mm 195X960X680 195X1,160X680 195X1,400X680 Sound level (H/L) 220 V dB(A) 35/32 35/32 35/32 38/33 39/34 40/35
Machine weight kg 24 28 33 240 V 37/34 37/34 37/34 40/35 41/36 42/37
Liquid (Flare) mm 6.4 9.5 9.5 Dimensions FXLQ mm 600X1,000X222 600X1,000X222 600X1,140X222 600X1,140X222 600X1,420X222 600X1,420X222
Piping
12.7 15.9 15.9 (HXWXD)
connections Gas (Flare) FXNQ 610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220
Drain VP20 (External Dia, 26/Internal Dia, 20) FXLQ kg 25 25 30 30 36 36
Machine weight
FXNQ 19 19 23 23 27 27
Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5
Piping
connections Gas (Flare) 12.7 12.7 12.7 12.7 12.7 15.9
Wall Mounted Type Drain 21O.D.
29 30
SPECIFICATIONS
Connection unit series indoor units
OUTDOOR UNITS
* A type of BEV unit is necessary for each Connection unit series indoor unit.
* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other
series, cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units.
Cooling Only
However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating MODEL RXMQ4PVE RXMQ5PVE RXMQ6PVE
switchover will be possible.
* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable Power supply 1-phase, 220-230 V, 50 Hz/220 V
cooling/heating switchover. Kcal/h 9,600 12,000 13,300
* Group control between Connection Unit series equipment within one system is possible. However, group control with the other Cooling capacity Btu/h 38,200 47,700 52,900
VRV indoor units is not possible. kW 11.2 14.0 15.5
Power consumption kW 2.95 3.97 4.44
Capacity control % 24 to 100
Ceiling Suspended Cassette Type (50 Hz only) Casing colour Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type
Compressor
Motor output kW 2.5 3.0 3.5
Indoor unit FXUQ71MAV1 FXUQ100MAV1 FXUQ125MAV1
MODEL Airflow rate m /min 106
3
31 32
OPTION LIST
INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Duct Type
No. Type FXFQ25L FXFQ32L FXFQ40L FXFQ50L FXFQ63L FXFQ80L FXFQ100L FXFQ125L No. Type FXMQ20P FXMQ50P FXMQ100P
Item Item FXMQ25P FXMQ40P FXMQ63P FXMQ125P
1 Decoration Panel BYCP125K-W1 FXMQ32P FXMQ80P FXMQ140P
2 Sealing member of air discharge outlet KDBH55K160F 65% KAF372AA36 KAF372AA56 KAF372AA80 KAF372AA160
3 Panel spacer KDBP55H160FA 1 High efficiency filter
90% KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160
High efficiency filter unit 65% KAFP556B80 KAFP556B160
2 Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160
High efficiency filter unit 90% KAFP557B80 KAFP557B160
Replacement high efficiency filter 65% KAFP552B80 KAFP552B160 3 Long life replacement filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160
Replacement high efficiency filter 90% KAFP553B80 KAFP553B160 4 Long life filter chamber kit KAF375AA36 KAF375AA56 KAF375AA80 KAF375AA160
4 Filter related
Filter chamber KDDFP55B160 White KTBJ25K36W KTB25KA56W KTB25KA80W KTB25KA160W
Long life replacement filter Non-woven type KAFP551K160 5 Service panel Fresh white KTBJ25K36F KTBJ25K56F KTBJ25K80F KTBJ25K160F
Ultra long-life filter KAFP55B160
Replacement ultra long-life filter KAFP55H160H Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T
Without T shape and fan KDDP55B160 6 Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
Chamber type
5 Fresh air intake kit With T shape without fan KDDP55B160K
Direct installation type KDDP55X160
6 Branch duct chamber KDJP55B80 KDJP55B160 Ceiling Suspended Type
7 Chamber connection kit KKSJ55KA160
No. Type FXHQ32MA FXHQ63MA FXHQ100MA
8 Insulation kit for high humidity KDTP55K80 KDTP55K160 Item
1 Drain pump kit KDU50N60VE KDU50N125VE
2 Replacement long-life filter (Resin net) KAF501DA56 KAF501DA80 KAF501DA112
Ceiling Mounted Cassette (Compact Multi Flow) Type 3 L-type piping kit (for upward direction) KHFP5MA63 KHFP5MA160
No. Item Type FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M
1 Decoration panel BYFQ60B8W1
2 Sealing member of air discharge outlet KDBH44BA60 Wall Mounted Type
3 Panel spacer KDBQ44BA60A No. Type FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P
Replacement long-life filter KAFQ441BA60
Item
4
1 Drain pump kit K-KDU572EVE
5 Fresh air intake kit Direct installation type KDDQ44XA60
33 34
OPTION LIST
OUTDOOR UNITS CONTROL SYSTEMS
Cooling only System Configuration
No. Type RXMQ4P RXMQ5P RXMQ6P No. Item Model No. Function
Item
1 Cool/Heat Selector KRC19-26A 1 Residential central remote controller Note 3 •Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF,
DCS303A51 temperature settings and scheduling can be controlled individually for indoor units.
6 Wire fixture for preventing overturning K-KYZP15C 4 Schedule timer Note 2 •Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units
DST301BA61 (128 units). Can turn units ON/OFF twice per day.
5 Interface adaptor for SkyAir-series For SkyAir, FD(Y)M-FA, FDY-KA DTA102A52 •Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET
FDYB-KA, FVY(P)J-A, FXUQ-MA communication system adopted for the VRV System.
2 Cool/Heat Selector KHRP26M22H (Max. 4 branch) 8-1 Mounting plate KRP4A92 •Fixing plate for DTA109A51
CONTROL SYSTEMS
1-1 Option Hardware DIII-NET plus adaptor DCS601A52 •Additional 64 groups (10 outside units) is possible.
1-2 Electrical box with earth terminal (4 blocks) KJB411A •Wall embedded switch box.
Operation Control System Optional Accessories 2 intelligent Touch Basic Hardware intelligent Touch Manager DCM601A51 •Air-conditioning management system that can be controlled by touch screen.
Manager
No. Type FXFQ-L FXZQ-M FXCQ-M FXKQ-MA FXDQ-PB FXMQ-L FXHQ-MA FXAQ-L FXLQ-MA FXUQ-MA
FXDQ-NB FXNQ-MA
Item 2-1 Option Hardware iTM plus adaptor DCM601A52 •Additional 64 groups (10 outdoor units) is possible.
Max. 7 iTM plus adaptors can be connected to intelligent Touch Manager.
1 Remote controller Wireless C/O BRC7F635F BRC7E531W BRC7C67 BRC4C63 BRC4C66 BRC4C66 BRC7EA66 BRC7EA619 BRC4C64 BRC7CA529W
2-2 iTM integrator DCM601A53 •Max. 5 intelligent Touch Managers can be integrated.
H/P BRC7F634F BRC7E530W BRC7C62 BRC4C61 BRC4C65 BRC4C65 BRC7EA63W BRC7EA618 BRC4C62 BRC7CA528W
2-3 Software iTM power proportional DCM002A51 •Power consumption of indoor units are calculated based on operation status of the indoor unit and
Wired BRC1C62 distribution outside unit power consumption measured by kWh metre.
2 Navigation remote controller (Wired remote controller) BRC1E61 2-4 iTM energy navigator DCM008A51 •Building energy consumption is visualised.
Wasted air-conditioning energy can be found out.
3 Wired remote controller with weekly schedule timer BRC1D61 2-5 Di unit DEC101A51 •8 pairs based on a pair of On/Off input and abnormality input.
8 Remote sensor (for indoor temperature) KRCS01-4B KRCS01-1B KRCS01-4B KRCS01-1B 4 *2 Interface for use in LONWORKS ®
DMS504B51 •Interface unit to allow communications between VRV and BMS. Operation and monitoring of
air-conditioning systems through LONWORKS communication.
®
9 Installation box for adaptor PCB Note 2,3 Note 4.6 Note 2,3
— Note 4,6 Note 2,3 Note 3 Note 2,3
— KRP1BA97 5 Contact/analogue Unification adaptor for DCS302A52 •Interface between the central monitoring board and central control units.
KRP1H98 KRP1BA101 KRP1B96 KRP1BA101 KRP4A96 KRP1CA93 KRP4AA93 computerised control
signal
10 External control adaptor for outdoor unit DTA104A62 DTA104A62 DTA104A61 DTA104A61 DTA104A53 DTA104A61 DTA104A62 DTA104A61 DTA104A61 —
Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
®
*2. LONWORKS is a trademark of Echelon Corporation registered in the United States and other countries.
®
11 Adaptor for multi tenant DTA114A61 — DTA114A61 — DTA114A61 — *3. Installation box for adaptor must be obtained locally.
Note: 1. Installation box is necessary for each adaptor marked . 3. Only one installation box can be installed for each indoor unit. 5. Installation box is necessary for second adaptor.
2. Up to 2 adaptors can be fixed for each installation box. 4. Up to 2 installation boxes can be installed for each indoor unit. 6. Installation box is necessary for each adaptor.
35 36
MEMO