MORS Relais Brochure-Railway-Relays-V1-4 PDF
MORS Relais Brochure-Railway-Relays-V1-4 PDF
Railway relays
Mors Smitt Railway Technology
Railway relays
Signalling & control relays
Protection relays
Measuring sensors
DSD footpedal
Retrofit / replacement
Signalling relays N.S1
Signalling relays B1 / B2
Signalling relays Q-style / BR930
Mors Smitt is entirely devoted to develop and manufacture electrical equipment, components and
control solutions for railway and trackside applications. Mors Smitt has become leading in this demanding
market. We supply the largest international rolling stock manufacturing enterprises as well as the main
world rail operators.
Mors Smitt has been manufacturing relays since 1902. We have a wide range of relays fit for all railway
rolling stock applications. Our technology was developed in the 1960’s and has proven itself over time
and is still the most reliable and economic solution for electrical control applications today. Innovation
continues and Mors Smitt is a true relay specialist with hugh know-how of applications inside rolling
stock.
Market characteristics
The railway world is characterized by a tough and uncompromising work environment. Constant
shock & vibration, dust, temperature and humidity variations and electric disturbances demand
components working under harsh conditions. This is the world in which Mors Smitt has invested best
efforts, parts and components that work unquestioningly, offer a long effective life and result in low
lifecycle cost.
Mors Smitt companies have certified quality and environmental management systems according the
leading international standards, ISO 9001:2008, ISO 14001 and the railway specific IRIS standard.
Mors Smitt continuously improves its products and services. Specifications are changed without prior notice.
No rights can be derived from specifications in this brochure. Changes and printed errors reserved.
September 2015
5
www.morssmitt.com
New solutions are co-designed with railway operators
and contractors, creating safer railway networks
General content
A- / B-platform 61
- Design features 62
- Options 63
- Specifications per relay 64 - 104
- Example ordering scheme 105
- Dimensions 106 - 107
- Electrical life expectancy 108 - 115
- Sockets 116 - 117
CU-platform 119
- Design features 120
- Options 121
- Specifications per relay 122 - 130
- Example ordering scheme 131
- Dimensions 132
- Electrical life expectancy 133 - 135
- Sockets 136
C-platform 137
- Design features 138
- Options 139
- Specifications per relay 140 - 146
- Example ordering scheme 147
- Dimensions 148
- Electrical life expectancy 149 - 152
- Sockets 153
Specials 155
- Design features 156
- Specifications per relay 157 - 166
- Dimensions 167 - 170
- Electrical life expectancy 171 - 173
- Sockets 174
www.morssmitt.com
Relay platforms
D-platform Page 15
Compact multi functional relays for all different kind of applications. Up to 4 change-over contacts these
relays all have the same base of 40 x 40 mm. 8-pole configurations in different types also available.
A - / B-platform Page 61
Heavy duty multi functional relays with very long mechanical contact life of 100 million cycles. Up to 4
change-over contacts these relays all have the same base of 45 x 45 mm. Different types available for many
different applications. B-relays with higher continuous contact load and higher relay cover than A-relays.
Flashing Monitoring
www.morssmitt.com
Relay platforms
www.morssmitt.com
Selection table
The details of each relay are described in the product pages in the next chapters.
A first distinction can be made with 2 graphs. The first graph shows different relay platforms with respect
to the number of contacts and the maximum continuous contact current.
40 contacts
C-platform
Contacts: 9 N/O-N/C
Max. cont. current: 8 A
D8-U200 relays
Safety critical
Contacts: 8 C/O
Instantaneous
Max. cont. current: 10 A
Latching
Instantaneous
Monitoring
Latching
Flashing
Maximum number of contacts
10
www.morssmitt.com
Selection table
The second graph shows a comparison of different relay platforms with respect to their electrical life
expectancy.
100
10
D
CU
Millions of cycles
B
C
A
1
0.1
0.50 1.00 10.00
Comparison chart of life expectancy different relay platforms (for details see life expectancy
curves of each relay)
11
www.morssmitt.com
Selection table
Integrated snap-lock
Push-to-test button
Polarisation diode
Position indicator
AgSnO2 contacts
Gold contacts
LED indicator
Current coil
Max. cont.
Page
Type Platform Contacts current Coil input
Instantaneous
D-U200 D 4 C/O 10 A DC o o o - - o • - o • o o o o o - o • o - - o o 19
D-U200-W D 4 N/O - N/C 10 A DC • o o - - o • - o • o o o o - - o • 0 - - o o 20
D-U300 D 4 C/O 10 A AC - o o - - o • - o - - - - o o o - • o - - - - 21
DGG-U200 D 2 C/O 10 A DC - o o - • o • - o • o o - o - - o • o - - - - 22
D8-U200 D 8 C/O 10 A DC - o o - - o • - o • o o - o - - o • o - - o - 23
A 400 A A C/O 8A DC or AC o - - - - • - - o o - o - - - • - - • - - o - 64
AG 400 A 4 C/O 5A DC or AC o - • - - • - - o o - o - - - • - - • - - o - 65
AK 400 A 4 C/O 8A DC or AC o • - - - • - - o o - o - - - • - - • - - o - 66
AM 400 A 4 C/O 8A DC or AC o - - • - • - - o o - o - - - • - - • - - o - 67
B 400 B 4 C/O 12 A DC or AC • - - - - • - - o o - o - - - • - - • - - o - 68
BG 400 B 4 C/O 5A DC or AC o - • - - • - - o o - o - - - • - - • - - o - 69
BK 400 B 4 C/O 12 A DC or AC • - - - - • - - o o - o - - - • - - • - - o - 70
BM 400 B 4 C/O 12 A DC or AC o - - • - • - - o o - o - - - • - - • - - o - 71
CU/CP-U200-G CU 2 C/O 6A DC • - o - - - - - o - - - - - - • - - • - - - - 122
CU/CP-U300-G CU 2 C/O 6A AC • - o - - - - - o - - - - - - • - - • - - - - 123
CU/CP-U200-B CU 2 C/O 8A DC • - - - - o • - o - - - - - - • - - • - - - - 124
CU/CP-U200-D CU 1 C/O + 1 N/O 6A DC • - o - • - - - o - - - - - - • - - • - - - - 125
CU/CP-U200-U CU 1 C/O 8A DC - - o - - • - - o - - - - - - • - - • - - - - 126
CU/CP-U300-U CU 1 C/O 8A AC - - o - - • - - o - - - - - - • - - • - - - - 127
C C 9 N/O - N/C 8A DC • - - - - • - - o o - o - - - • - - • - - - - 140
CG C 9 N/O - N/C 5A DC or AC • - • - - • - - o o - o - - - • - - • - - o - 141
CK C 9 N/O - N/C 8A DC or AC • • - - - • - - o o - o - - - • - - • - - o - 142
CM C 9 N/O - N/C 8A DC • - - • - • - - o o - o - - - • - - • - - - - 143
Latching
BD-U200 D 3 C/O + 1 N/C 10 A DC - o o - - o • - - o o - - o - o - • o - - - o 24
KCD-U200 D 2 C/O 6A DC • - o - - o o - - o - o - o - o - • o - o - - 25
KDN-U200 D 8 C/O 10 A DC - o o - - o • - - o - - - o - o - • o - - - - 26
SB B 4/3 C/O 8A DC or AC o - - - - • - - - - - o - - - • - - • o - o - 72
TFBBU 400 B 4 C/O 12 A DC • - - - - • - - • - - - - - - • - - • - - - - 73
KCS/KCP-U200 CU 2 C/O 6A DC • - o - - o - - - - - - - - - • - - • - - - - 142
SC C 8 N/O - N/C 8A DC • - - - - • - - - - - - - - - • - - • - - - - 143
Timer
CTD4-U 1+2 D 4 C/O 10 A DC - o o - - o • - • • - o - o - - - • o - - • - 27
TDB2-U200 1 D 2 C/O 6A DC • - o - - o o - - • - o - o - o - • o - - - - 28
TDB4-U200 1 D 4 C/O 10 A DC - o o - - o • - • - - o - o - o - • o - - - - 29
TDE-U200 2 D 1 C/O + 1 N/O 6A DC • - o - - - o - - - - o - o - o - • o - - - - 30
TDE3-U200 2 D 3 C/O 10 A DC - - o - - - • - - - - - - o - o - • o - - - - 31
TDE4-U200 2 D 4 C/O 10 A DC - o o - - - • - - - - - - o - o - • o - - - - 32
TDE4N-U 2 D 4 C/O 10 A DC or AC - o o - - o • - • - - o - o - o - • o - - • - 33
TDBE-U200 1+2 D 2 C/O 6A DC • - o - - - o - - - - o - o - o - • o - - - - 34
TDBE4-U200 1+2 D 3 C/O + 1 N/C 10 A DC - o o - - - • - • - - o - o - o - • o - - - - 35
TDBE4-U300 1+2 D 3 C/O + 1 N/C 10 A AC - o o - - - • - • - - o - o - o - • o - - - - 36
1
Delay on pull-in
2
Delay on drop-out
12
www.morssmitt.com
Selection table
Integrated snap-lock
Push-to-test button
Polarisation diode
Position indicator
AgSnO2 contacts
Gold contacts
LED indicator
Current coil
Max. cont.
Page
Type Platform Contacts current Coil input
www.morssmitt.com
Selection table
Integrated snap-lock
Push-to-test button
Polarisation diode
Position indicator
AgSnO2 contacts
Gold contacts
LED indicator
Current coil
Max. cont.
Page
Type Platform Contacts current Coil input
Specials
Type Contacts Max. cont. current Coil input Main features Page
Instantaneous
303 19 N/O or N/C 8A DC Safety-critical, weld-no-transfer contacts 157
401 40 N/O or N/C 8A DC Safety-critical, weld-no-transfer contacts 159
CMP 2 C/O 6A AC No auxiliary power supply necessary, can be connected on 35 mm rail or any other other surface 161
RC 19A 1 C/O 6A AC Input via wire through ring core saturation transformer 164
D4-U200 module 4 N/O or N/C 10 A DC Module with 4 pole relay and socket, easy replacement for contactors 165
Instantaneous & timer
D8-U200 module 8 N/O or N/C 10 A DC Module with 8 pole relay and socket, easy replacement for contactors 166
Monitoring & timer
NSE 2 C/O 14 A AC Over- and undervoltage monitoring, time delay on pull-in 162
NSR 2 C/O 14 A AC Over- and undervoltage monitoring, 3-phase, time delay on pull-in 163
Latching
310 18 N/O or N/C 8A DC Safety-critical, weld-no-transfer contacts 158
407 40 N/O or N/C 8A DC Safety-critical, weld-no-transfer contacts 160
Time module
TB AO 0.25 s...40 s DC Converts instantaneous relay(s) to time delay relay(s), delay on pull-in, B 400 platform 176
TB OR 0.25 s...40 s DC Converts instantaneous relay(s) to time delay relay(s), delay on drop-out, B 400 platform 177
TALAO 0.25 s...63.75 min DC Converts instantaneous relay(s) to time delay relay(s), delay on pull-in, A 400 platform 178
TALOR 0.25 s...63.75 min DC Converts instantaneous relay(s) to time delay relay(s), delay on drop-out, A 400 platform 179
TBL AO 0.25 s...63.75 min DC Converts instantaneous relay(s) to time delay relay(s), delay on pull-in, B 400 platform 180
TBL OR 0.25 s...63.75 min DC Converts instantaneous relay(s) to time delay relay(s), delay on drop-out, B 400 platform 181
TA3 0.125 s...90 min DC Converts instantaneous relay(s) to time delay relay(s), delay on drop-out, A 400 platform, parallel wiring 182
Time module, flashing
TCAL 0.25 s...63.75 min DC Converts instantaneous relay(s) to flashing relay(s), symmetrical, A 400 platform 183
TAC 3 s...30 s DC Windshield wiper module 184
14
www.morssmitt.com
D-platform
15
www.morssmitt.com
D-platform
Design features
The unique D-platform is specifically designed to solve demanding applications in the railway market: high
DC breaking capacity and inductive load switching, offering long electrical life and low life cycle costs. The
D-platform offers ultimate flexibility to be suitable for many railway applications.
LED indication
Contacts
Up to 4 change-over contacts.
Standard, Ag contact material.
Back EMF diode
AgSnO2 or goldplated contact
Integrated to suppress the back EMF material on request.
from de-energizing the coil, to protect Calibrated contact pressure.
the external electronic control system
connected to the relay.
Magnetic arc blow-out
For inductive loads.
Sockets
We offer a wide range of mounting
sockets for wall, rail, flush or PCB-
mounting. Connections with screw,
spring clamp, faston, soldering or
crimp terminals. Mors Smitt unique pinning
14 silver plated, flat pins, for excellent
socket connection and protection
against corrosion.
Snap-lock
Integrated relay retaining clip for
sturdy mounting in the socket,
prevents reversed mounting.
16
www.morssmitt.com
Options D-platform
Options
The D-platform relays (and derived models) can be equipped with many options. The concept allows composing
the D-platform relays to almost any solution. However not all options or combinations are possible. All possible
options are mentioned in the product pages in this chapter. Detailed information about the options and
combinations is mentioned in the product datasheets, available on www.morssmitt.com
Contacts are mechanically connected in such a way that N/C contacts and N/O
W
contacts can never be closed at the same time.
Weld-no-transfer - If a N/O contact fails to open and the relay de-energises, none of the N/C contacts closes
- If a NC contact fails to open and the relay energises, none of the NO contacts closes
Weld-no-transfer contacts according EN 50205
M AgSnO2 contacts
Contacts which are highly resistant to welding for safety applications.
Mimimum contact current must be 100 mA.
E Goldplated contacts
Silver contacts with thin layer of gold to have a good resistance against corrosive
atmospheres. Suitable for switching low currents and low voltages.
DGG Low operating voltage The relay has a large pull-in voltage range of 40% - 125% of the nominal voltage.
L LED indicator
Built-in LED(s) to indicate the presence of power supply and the energizing
of the coil.
17
www.morssmitt.com
Options D-platform
Options
Transient voltage suppressor to protect the relay coil against surges and
Q Double zener coil
protection diode
to protect the system against a back EMF surge when the relay coil is
de-energized.
Contact 4-12 will make before contact 3-13 will break during
11 Make before break
contact
pull-in. During release, contact 3-13 will make before contact 4-12
will break. Contact 5-7/9 is a normal change-over contact
T Push-to-test button Relays equipped with test button to operate the relays manually.
C Low temperature
The minimum operating temperature is decreased from -25 oC to -40 oC or -50 oC
(depending on product).
Integrated ‘snap-lock’ which will hold the relay into the socket under all
Snap-
Integrated snap-lock circumstances and mounting directions, no external retaining clip necessary.
lock Prevents reversed mounting. (standard for most relays)
Key- Mechanical keying Positive mechanical keying relays to socket to prevent a relay being inserted
ing relays to socket in a wrong socket. (standard for most relays)
S Position indicator Mechanical indicator to indicate visually the position of the relay contacts.
18
www.morssmitt.com
Instantaneous
D-U200 10 A, 4 C/O
Plug-in railway relay with 4 change-over contacts.
Contact data
Amount and type of contacts 4 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Options
Maximum continuous current 10 A
• Weld-no-transfer contacts Maximum switching voltage 250 VDC, 440 VAC
• Low temperature (-50 OC), max. contact Minimum switching voltage 12 V (5 V with gold plated contacts)
current 8 A Minimum switching current 10 mA (1 mA with gold plated contacts)
• Gold plated contacts
Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• Special dust protection
230 VAC, 10 A (cos ϕ ≥ 0.7)
• LED coil indicator
• Bipolar LED indicator Contact resistance 15 mΩ (initial)
• AgSnO2 contacts, high resistant to welding Material Ag standard
• No magnetic arc blow-out Electrical life expectancy See curves on page 57
• Polarisation diode
• Double zener diode
• Push-to-test button Mechanical & environmental characteristics
• Coil for both AC and DC Mechanical life 50 x 106 operations
• Double make / double break (-50 OC) Weight 140 g (without options)
• No diode
• Make before break contact Operating temperature -25 °C...+70 °C
• Reversed polarity Humidity 95 % (condensation is permitted temporarily)
19
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 4 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Options
Maximum continuous current 10 A
• Low temperature (-50 OC), max. contact Maximum switching voltage 250 VDC, 440 VAC
current 8 A Minimum switching voltage 12 V (5 V with gold plated contacts)
• Gold plated contacts Minimum switching current 10 mA (1 mA with gold plated contacts)
• Special dust protection
Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• LED coil indicator
230 VAC, 10 A (cos ϕ ≥ 0.7)
• Bipolar LED indicator
• AgSnO2 contacts, high resistant to welding Contact resistance 15 mΩ (initial)
• No magnetic arc blow-out Material Ag standard
• Polarisation diode Contact gap > 1.5 mm
• Double zener diode
Electrical life expectancy Depends on application, see datasheet for more information
• Coil for both AC and DC
• Double make / double break (-50 OC)
Mechanical & environmental characteristics
• No diode
Mechanical life 50 x 106 operations
• Make before break contact
• Reversed polarity Weight 140 g (without options)
Operating temperature -25 °C...+70 °C
Humidity 95 % (condensation is permitted temporarily)
Timing diagram
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil * (Ω) Icoil (mA)
D-U201-W 24 16.8 30 2.5 270 89
D-U202-W 48 33.6 60 4.8 1103 44
D-U203-W 72 50.4 90 7.2 2406 30
D-U204-W 110 77 137.5 11 5330 21
D-U205-W 96 67.2 120 9.5 4400 22
D-U206-W 12 8.4 15 1.2 72 167
D-U207-W 36 25.2 45 3.5 562 64
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Connection diagram Other types on request
20
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 4 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Options
Maximum continuous current 10 A
• Low temperature (-40 OC), max. contact Maximum switching voltage 250 VDC, 440 VAC
current 8 A Minimum switching voltage 12 V (5 V with gold plated contacts)
• Gold plated contacts Minimum switching current 10 mA (1 mA with gold plated contacts)
• Special dust protection
Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• LED coil indicator
230 VAC, 10 A (cos ϕ ≥ 0.7)
• AgSnO2 contacts, high resistant to welding
• No magnetic arc blow-out Contact resistance 15 mΩ (initial)
• Push-to-test button Material Ag standard
• Double make / double break (-40 OC) Electrical life expectancy See curves on page 57
21
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 2 C/O
Maximum make current 16 A
Options Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Low temperature (-40 OC), max. contact Maximum continuous current 10 A
current 8 A Maximum switching voltage 250 VDC, 440 VAC
• Gold plated contacts Minimum switching voltage 12 V (5 V with gold plated contacts)
• Special dust protection Minimum switching current 10 mA (1 mA with gold plated contacts)
• AgSnO2 contacts, high resistant to welding Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• No magnetic arc blow-out 230 VAC, 10 A (cos ϕ ≥ 0.7)
• Polarisation diode
Contact resistance 15 mΩ (initial)
• Double zener diode
• Push-to-test button Material Ag standard
• Double make / double break (-40 OC) Electrical life expectancy See curves on page 57
• No diode
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 140 g (without options)
Timing diagram Operating temperature -25 °C...+70 °C (with option -40 oC)
Humidity 95 % (condensation is permitted temporarily)
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil * (Ω) Icoil-nom (mA) Pnom (W)
DGG-U201 24 9.6 30 1.9 270 85.7 2.1
DGG-U202 48 19.2 60 3.8 1103 43.2 2.1
DGG-U203 72 28.8 90 5.8 2406 28.8 2.1
DGG-U204 110 44 137.5 8.8 5330 18.9 2.1
DGG-U205 96 38.4 120 7.7 4400 22.3 2.1
Connection diagram
DGG-U206 12 4.8 15 1.0 72 181 2.2
DGG-U207 36 14.4 45 2.9 562 62 2.2
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
22
www.morssmitt.com
Instantaneous
D8-U200 10 A, 8 C/O
Plug-in railway relay with 8 change-over contacts.
Contact data
Amount and type of contacts 8 C/O
Maximum make current 16 A
Options Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Low temperature (-50 OC), max. contact Maximum continuous current 10 A
current 8 A Maximum switching voltage 250 VDC, 440 VAC
• Gold plated contacts Minimum switching voltage 12 V (5 V with gold plated contacts)
• Special dust protection Minimum switching current 10 mA (1 mA with gold plated contacts)
• LED coil indicator Maximum contact resistance 15 mΩ
• AgSnO2 contacts, high resistant to welding Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• No magnetic arc blow-out 230 VAC, 10 A (cos ϕ ≥ 0.7)
• Polarisation diode
Material Ag standard
• Double zener diode
• Coil for both AC and DC Electrical life expectancy See curves on page 57
• Double make / double break (-50 OC)
• No diode Mechanical & environmental characteristics
Mechanical life 10 x 106 operations
Weight 300 g (without options)
Timing diagram Operating temperature -25 °C...+70 °C
Humidity 95 % (condensation is permitted temporarily)
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Rcoil * (Ω) Pnom (W)
D8-U201 24 16.8 30 233 2.8
D8-U202 48 33.6 60 680 2.8
D8-U203 72 50.4 90 1590 2.8
D8-U204 110 77 137.5 3769 2.8
D8-U205 96 67.4 120 3547 2.8
Connection diagram D8-U206 12 8.4 15 76 2.8
D8-U207 36 25.2 45 680 2.8
23
www.morssmitt.com
Latching
Contact data
Amount and type of contacts 3 C/O + 1 N/C
Options Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Low temperature (-40 OC), max.
Maximum continuous current 10 A
contact current 8 A
• Back EMF protection diode Maximum switching voltage 250 VDC, 440 VAC
• Gold plated contacts Minimum switching voltage 12 V (5 V with gold plated contacts)
• Special dust protection Minimum switching current 10 mA (1 mA with gold plated contacts)
• AgSnO2 contacts, high resistant to welding Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• No magnetic arc blow-out 230 VAC, 10 A (cos ϕ ≥ 0.7)
• Polarisation diode Contact resistance 15 mΩ (initial)
• Reversed polarity (+ on pin 6) Material Ag standard
• Double make / double break (-40 OC)
Electrical life expectancy See curves on page 57
Type Unom (VDC) Umin (VDC) Umax (VDC) Rcoil * (Ω) Pnom (W)
2-6
BD-U201 24 16.8 30 618 1.7
BD-U202 48 33.6 60 2383 1.7
BD-U203 72 50.4 90 6550 1.7
BD-U204 110 77 137.5 14700 1.7
BD-U205 96 67.2 120 14700 1.7
BD-U206 12 8.4 15 135 1.7
BD-U207 36 25.2 45 1425 1.7
Connection diagram
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
24
www.morssmitt.com
Latching
KCD-U200 6 A, 2 C/O
Plug-in bistable railway relay with 4 change-over contacts. The contacts remain in
the last powered position. The position is clearly visible (position indicator optional).
Contact data
Number and type of contacts 2 C/O
Maximum make current 15 A
Options Maximum continuous current 6A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
• Magnetic arc blow-out
250 VAC (then max. current = 2.6 A)
• Low temperature (-40 OC)
• Back EMF protection diode Minimum switching voltage 12 V (5 V with gold plated contacts)
• Gold plated contacts Minimum switching current 10 mA (1 mA with gold plated contacts)
• Special dust protection (only for fixed Maximum contact resistance 15 mΩ
time setting) Material Ag standard
• Double zener diode Maximum switching capacity and See curves on page 133
• Position indicator electrical life expectancy
• Double make / double break
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Rcoil * (Ω) Inom (mA)
2-5 KCD-U201 24 16.8 30 500 48
KCD-U202 48 33.6 60 2060 23
KCD-U203 72 50.4 90 4900 15
KCD-U204 110 77 137.5 7800 11
KCD-U205 96 67.2 120 7800 12
KCD-U206 12 8.4 15 137 88
KCD-U207 36 25.2 45 1300 29
Connection diagram * The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
25
www.morssmitt.com
Latching
KDN-U200 10 A, 8 C/O
Plug-in bistable railway relay with 8 change-over contacts. The contacts remain in
the last powered position. The position is clearly shown via an indicator.
Contact data
Amount and type of contacts 8 C/O
Maximum make current 16 A
Options Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Low temperature (-40 OC), max. contact Maximum continuous current 10 A
current 8 A Maximum switching voltage 250 VDC, 440 VAC
• Back EMP protection diode Minimum switching voltage 12 V (5 V with gold plated contacts)
• Gold plated contacts Minimum switching current 10 mA (1 mA with gold plated contacts)
• Special dust protection Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• AgSnO2 contacts, high resistant to welding 230 VAC, 10 A (cos ϕ ≥ 0.7)
• No magnetic arc blow-out
Maximum contact resistance 15 mΩ
• Double zener diode
• Double make / double break (-40 OC) Material Ag standard
Electrical life expectancy See curves on page 57
1-2 right
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil * (Ω) Pnom (W)
KDN-U201 24 16.8 30 9.6 178 3.2
KDN-U202 48 33.6 60 19.2 666 3.3
KDN-U203 72 50.4 90 28.8 2059 3.3
KDN-U204 110 77 137.5 44 3850 3.0
KDN-U205 96 67.2 120 38.4 3600 2.6
KDN-U206 12 8.4 15 4.8 94 3.3
Connection diagram KDN-U207 36 25.2 45 14.4 370 3.2
RED L E FT R I G HT GREEN
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
1 3 4 5 6 6 5 4 3 1
2 11 13 12 14 7 9 8 10 10 8 9 7 14 12 13 11 2
26
www.morssmitt.com
Timer
Almost any timing diagram is possible: for example time delays with
delay on pull-in, on drop-out or both, symmetrical or asymmetrical flashing, 1-shot,
2-shot, 3-shot etc. or a combination of all these.
Delay/pulse times are adjustable with 1 or 2 lockable knobs. The relay can also be
supplied with fixed delay/pulse times (no knobs).
Contact data
Number and type of contacts 4 C/O (number of change-over contacts
depends on desired timing diagram)
Timing diagram example
Maximum make current 16 A
(depending on configuration)
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag
Maximum switching capacity and See curves on page 57
electrical life expectancy
27
www.morssmitt.com
Timer
Time delay
Time delay function Delay on pull-in
Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
0.3... 3 min 0.6...6 min 1...10 min
Options
3...30 min
• Magnetic arc blow-out
Contact data
• Low temperature (-40 OC)
Amount and type of contacts 2 C/O
• Gold plated contacts
• Extra dust protection Maximum make current 15 A
• Double zener diode over input Maximum continuous current 6A
• Double make / double break Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag
Maximum switching capacity and See curves on page 57
electrical life expectancy
Timing diagram
Mechanical & environmental characteristics
in
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
TDB2-U201 24 16.8 30
on TDB2-U202 48 33.6 60
TDB2-U203 72 50.4 90
Connection diagram
TDB2-U204 110 77 137.5
TDB2-U205 96 67.2 120
TDB2-U207 36 25.2 45
Other types on request
28
www.morssmitt.com
Timer
Time delay
Time delay function Delay on pull-in
Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
Options 0.3... 3 min 0.6...6 min 1...10 min
• Low temperature (-40 C)
O 3...30 min
Contact data
• Gold plated contacts
• Extra dust protection Amount and type of contacts 4 C/O
• AgSnO2 non-weldable contact Maximum make current 16 A
• No magnetic arc blow-out Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Double zener diode over input Maximum continuous current 10 A
• Double make / double break Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos ϕ > 0.7)
Maximum contact resistance 15 mΩ
Material Ag standard
Timing diagram Electrical life expectancy See curves on page 57
in
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 160 g (without options)
Operating temperature -25 °C...+70 °C
out
Humidity 93 %
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
on
TDB4-U201 24 16.8 30
TDB4-U202 48 33.6 60
Connection diagram
TDB4-U203 72 50.4 90
TDB4-U204 110 77.0 138
TDB4-U205 96 67.2 120
TDB4-U207 36 25.2 45
Other types on request
29
www.morssmitt.com
Timer
Time delay
Time delay function Delay on drop-out (without auxiliary power supply)
Options Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 1...10 s
3...30 s 10...100 s
• Magnetic arc blow-out
• Low temperature (-40 OC) Contact data
• Gold plated contacts Amount and type of contacts 1 C/O + 1 N/O
• Extra dust protection Maximum make current 15 A
• Double zener diode over input Maximum continuous current 6A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag
Maximum switching capacity and See curves on page 133
electrical life expectancy
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
TDE-U201 24 16.8 30
TDE-U202 48 33.6 60
TDE-U203 72 50.4 90
TDE-U204 110 77.0 138
Connection diagram
TDE-U205 96 67.2 120
TDE-U207 36 25.2 45
Other types on request
30
www.morssmitt.com
Timer
Time delay
Time delay function Delay on drop-out with auxiliary power supply
Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
Options 0.3... 3 min 0.6...6 min 1...10 min
3...30 min
• Low temperature (-40 OC)
• Gold plated contacts Contact data
• Extra dust protection Amount and type of contacts 3 C/O
• AgSnO2 ‘non weldable’ contacts
Maximum make current 16 A
• No magnetic arc blow-out
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos ϕ > 0.7)
Maximum contact resistance 15 mΩ
Material Ag
Electrical life expectancy See curves on page 57
Timing diagram
1-2 Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 140 g (without options)
Contacts 5-7 Operating temperature -25 °C...+70 °C
closed Humidity 90 %
open Nominal voltage
out Type Unom (VDC) Umin (VDC) Umax (VDC)
TDE-U201 24 16.8 30
TDE-U202 48 33.6 60
toff TDE-U203 72 50.4 90
Connection diagram TDE-U204 110 77.0 138
TDE-U205 96 67.2 120
TDE-U207 36 25.2 45
Other types on request
31
www.morssmitt.com
Timer
Time delay
Time delay function Delay on drop-out (without auxiliary power supply)
(Model TDE4-200 shown)
Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
Options
10...100 s
• Low temperature (-40 OC) Contact data
• Gold plated contacts Number and type of contacts 4 C/O
• Extra dust protection
Maximum make current 16 A
• No magnetic arc blow-out
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos ϕ > 0.7)
Maximum contact resistance 15 mΩ
Material Ag standard
Electrical life expectancy See curves on page 57
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
TDE4-U201 24 16.8 30
TDE4-U202 48 33.6 60
TDE4-U203 72 50.4 90
TDE4-U204 110 77.0 138
Connection diagram
TDE4-U205 96 67.2 120
TDE4-U207 36 25.2 45
Other types on request
Dimensions xx
See page 55
Mounting possibilities & sockets See page 59
xx
Detailed information and datasheets available on www.morssmitt.com
32
www.morssmitt.com
Timer
Time delay
Time delay function Delay on drop-out (without auxiliary power supply)
Available time ranges, adjustable (xx) 0...1 s 0...3 s 0...6 s
0...10 s 0...30 s 0...60 s
Options
0...100 s 0...180 s
• Low temperature (-40 OC) Contact data
• Gold plated contacts Number and type of contacts 4 C/O
• AgSnO2 ‘non weldable’ contacts
Maximum make current 16 A
• Extra dust protection
• Double zener diode over input Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Double make / double break Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos ϕ > 0.7)
Maximum contact resistance 15 mΩ
Material Ag standard
Electrical life expectancy See curves on page 57
Timing diagram
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 190 g (with adjustable knob)
Operating temperature -25 °C...+70 °C
Humidity 93 %
Nominal voltage
Type Unom (V) Umin (V) Umax (V)
TDE4N-U AC/DC 72-230 AC 57.6 DC 50.4 AC 276 DC 287.5
Other types on request
Connection diagram
33
www.morssmitt.com
Timer
Time delay
Time delay function Delay on pull-in and delay on drop-out
Options Available time ranges, independently 0.1...1 s 0.3...3 s 0.6...6 s
adjustable for pull-in (x) and drop- 1...10 s 3...30 s 6...60 s
• Magnetic arc blow-out out (y) 0.3... 3 min 0.6...6 min 1...10 min
• Low temperature (-40 OC) 3... 30 min 6...60 min
• Gold plated contacts
Every combination of tx and ty is possible
• Extra dust protection
• Double zener diode over input Contact data
Number and type of contacts 2 C/O
Maximum make current 15 A
Maximum continuous current 6A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Timing diagram Maximum contact resistance 15 mΩ
1-2
Material Ag + 0.2 μm Au
Maximum switching capacity and See curves on page 133
electrical life expectancy
7-6 or contact 5-6
Nominal voltage
Connection diagram Type Unom (VDC) Umin (VDC) Umax (VDC)
TDBE-U201 24 16.8 30
TDBE-U202 48 33.6 60
supply 1 and 2 TDBE-U203 72 50.4 90
TDBE-U204 110 77.0 138
contact input
TDBE-U205 96 67.2 120
or t on toff TDBE-U207 36 25.2 45
Other types on request
voltage input
Dimensions See page 55
t on t off Mounting possibilities & sockets See page 59
Detailed information and datasheets available on www.morssmitt.com
34
www.morssmitt.com
Timer
Time delay
Options Time delay function Delay on pull-in and delay on drop-out
• Low temperature (-40 C) O Available time ranges, independently 0...1 s 0...3 s 0...6 s
• Gold plated contacts adjustable for pull-in (x) and drop- 0...10 s 0...30 s 0...60 s
• AgSnO2 ‘non weldable’ contacts out (y) 0... 3 min 0...6 min 0...10 min
• Extra dust protection 0... 30 min 0...60 min 0...120 min
• Double zener diode over input Every combination of tx and ty is possible
Other ranges on request
Contact data
Number and type of contacts 4 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Timing diagram Minimum switching voltage 12 V (5 V with gold plated contacts)
1-2
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos φ > 0.7)
5-2
Maximum contact resistance 15 mΩ
Material Ag standard
Electrical lif expectancy See curves on page 57
Mechanical & environmental characteristics
out
www.morssmitt.com
Timer
Time delay
Time delay function Delay on pull-in and delay on drop-out
Options
Available time ranges, independently 0...1 s 0...3 s 0...6 s
• Low temperature (-40 OC) adjustable for pull-in (x) and drop- 0...10 s 0...30 s 0...60 s
• Gold plated contacts out (y) 0... 3 min 0...6 min 0...10 min
• AgSnO2 ‘non weldable’ contacts 0... 30 min 0...60 min 0...120 min
• Extra dust protection Every combination of tx and ty is possible
Other ranges on request
Contact data
Number and type of contacts 4 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Timing diagram Minimum switching current 10 mA (1 mA with gold plated contacts)
1-2
36
www.morssmitt.com
Timer & instantaneous
Time delay
Time delay function Delay on pull-in and instantaneous
Options
Available time ranges, independently 0.1...1 s 0.3...3 s 0.6...6 s
• Low temperature (-40 OC) adjustable for pull-in (x) and drop- 1...10 s 3...30 s 6...60 s
• 2 LEDs for status indication out (y) 0.3...3 min 0.6...6 min 1...10 min
• Double zener diode over input 3... 30 min
Contact data
Number and type of contacts 2 instantaneous C/O and 2 time delay C/O
Maximum make current 14 A
Maximum continuous current 8A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 100 mA
Timing diagram Maximum contact resistance 25 mΩ
Vin Material AgNi + 0.15 µm Au
Maximum switching capacity and See curves on page 58
electrical life expectancy
Vinstantaneous contacts
Mechanical & environmental characteristics
Mechanical life 20 x 106 operations
Weight 125 g (without options)
Vdelayed contacts
Operating temperature -25 °C...+70 °C
Humidity 80 %
37
www.morssmitt.com
Timer & instantaneous
Time delay
Time delay function Delay on pull-in and instantaneous
Options Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
• Low temperature (-40 OC)
0.3...3 min 0.6...6 min 1...10 min
• 2 LEDs for status indication
3...30 min
Contact data
Number and type of contacts 2 instantaneous C/O and 2 time delay C/O
Maximum make current 14 A
Maximum continuous current 8A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 100 mA
Maximum contact resistance 25 mΩ
Material AgNi + 0.15 µm Au
Timing diagram Maximum switching capacity and See curves on page 58
Vin electrical life expectancy
Nominal voltage
Type Frequency (Hz) Unom (VDC) Umin (VDC) Umax (VDC)
ton TDDB-U306 50 240 192 288
Connection diagram Other types on request
1 3 5 4 6
t
38
www.morssmitt.com
Timer & instantaneous
Time delay
Time delay function Delay on pull-in and instantaneous
Available time ranges, adjustable (xx) 0.1...1 s 0.3...3 s 0.6...6 s
1...10 s 3...30 s 6...60 s
Options 0.3...3 min 0.6...6 min 1...10 min
3...30 min 6...60 min
• Low temperature (-40 OC)
• Gold plated contacts Contact data delayed contacts
• Extra dust protection Number and type of contacts 2 C/O 4 C/O
• No magnetic arc blow-out Maximum make current 10 A 16 A
• Double zener diode Peak inrush current - 200 A (withstand > 10 x
200 A @ 10 ms, 1 min)
Maximum continuous current 8A 10 A
Maximum switching voltage 350 VDC, 380 VAC 250 VDC, 440 VAC
Minimum switching voltage 12 V 12 V
Minimum switching current 10 mA 10 mA
Maximum breaking capacity - 110 VDC, 8 A (L/R < 15 ms)
230 VDC, 10 A (cos ϕ > 0.7)
Maximum contact resistance - 10 mΩ
Timing diagram Material Ag Ag
in
Maximum switching capacity and See curves on datasheet See curves on datasheet
electrical life expectancy
Mechanical & environmental characteristics
out-I Mechanical life 30 x 106 operations
Weight 260 g (without options)
Operating temperature -25 °C...+70 °C
out-T
Humidity 95 %
Nominal voltage
ton
Type Unom (VDC) Umin (VDC) Umax (VDC)
TDD4B2-U201 24 16.8 30
Connection diagram TDD4B2-U202 48 33.6 60
TDD4B2-U203 72 50.4 90
L R TDD4B2-U204 110 77.0 137.5
TDD4B2-U205 96 67.2 120
TDD4B2-U207 36 25.2 45
39
www.morssmitt.com
Monitoring
Contact data
Amount and type of contacts 2 C/O
Maximum make current 16 A
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
Maximum continuous current 10 A
Options Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
• Low temperature (-40 OC), max. contact
Minimum switching current 10 mA (1 mA with gold plated contacts)
current 8 A
• Gold plated contacts Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
• Special dust protection 230 VAC, 10 A (cos ϕ ≥ 0.7)
• AgSnO2 contacts, high resistant to welding Contact resistance 15 mΩ (initial)
• Double make / double break Material Ag
Electrical life expectancy See curves on page 57
40
www.morssmitt.com
Monitoring
Contact data
Number and type of contacts 4 C/O
Maximum make current 16 A
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Timing diagram Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag
Maximum switching capacity and See curves on page 57
electrical life expectancy
41
www.morssmitt.com
Monitoring
Contact data
Options Amount and type of contacts 1 C/O + 1 N/O
Maximum make current 15 A
• Low temperature (-40 OC) Maximum continuous current 6A
• Gold plated contacts
Maximum switching voltage 300 VDC (then max. current = 300 mA)
• Special dust protection
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Contact resistance 15 mΩ (initial)
Material Ag
Mechanical swithcing cpacity and See curves on page 133
electrical life expectancy
Nominal voltage
Type Unom (VDC) Uadjust. min (VDC) Uadjust. max (VDC) Power (VA)
UMD-U316 150 115 185 < 1.5
UMD-U319 100 55 120 < 1.3
Other types on request
Connection diagram
42
www.morssmitt.com
Flashing
Pulse specifications
Pulse function Flashing (symmetrical); duty cycle 1/2
Pulse rate (xx) 20...60 imp/min adjustable per lockable knob
Options
40...120 imp/min adjustable per lockable knob
• Low temperature (-40 OC) Fixed without knob (set in factory)
• Extra dust protection Contact data
Number and type of contacts 2 C/O
Maximum make current 14 A
Maximum continuous current 8A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 100 mA
Material AgCdO
Maximum switching capacity and See curves on page 58
electrical life expectancy
Timing diagram
in Mechanical & environmental characteristics
Mechanical life 20 x 106 operations
Weight 90 g (without options)
Operating temperature -25 °C...+70 °C
Humidity 95 %
out
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
FDA-U201 24 16.8 30
FDA-U202 48 33.6 60
Connection diagram
FDA-U203 72 50.4 90
FDA-U204 110 77.0 138
FDA-U205 96 67.2 120
imp/min
FDA-U207 36 25.2 45
Other types on request
43
www.morssmitt.com
Flashing
Pulse specifications
Pulse function Flashing (symmetrical); duty cycle 1/2
Options
Pulse rate (xx) 20...60 imp/min adjustable per lockable knob
• Low temperature (-40 OC) 40...120 imp/min adjustable per lockable knob
• Extra dust protection Fixed without knob (set in factory)
Contact data
Number and type of contacts 2 C/O
Maximum make current 14 A
Maximum continuous current 8A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 100 mA
Material AgCdO
Maximum switching capacity and See curves on page 58
Timing diagram electrical life expectancy
in
Mechanical & environmental characteristics
Mechanical life 20 x 106 operations
Weight 90 g (without options)
Operating temperature -25 °C...+70 °C
Humidity 95 %
out
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
FDA-U301 24 19.2 28.8
FDA-U303 220 176 264
FDA-U305 110 88 132
Connection diagram
Other types on request
imp/min
44
www.morssmitt.com
Flashing
Pulse specifications
Pulse function Flashing (symmetrical); duty cycle 1/2
Pulse rate (xx) Selectable between 300 imp/min and 1/60 imp/min
Options Adjustable pulse time On request
• Low temperature (-40 OC)
• Gold plated contacts Contact data
• Extra dust protection Amount and type of contacts 4 C/O
• AgSnO2 non weldable contacts Maximum make current 16 A
• No magnetic are blow-out
Peak inrush current 200 A (withstand > 10 x 200 A @ 10 ms, 1 min)
• Double zener diode over coil
• Double make / double break Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum breaking capacity 110 VDC, 8 A (L/R < 15 ms)
230 VAC, 10 A (cos ϕ > 0.7)
Contact resistance 15 mΩ (initial)
Material Ag standard
Electrical life expectancy See curves on page 57
45
www.morssmitt.com
Flashing
46
www.morssmitt.com
Flashing
Contact data
Number and type of contacts 4 C/O
Maximum make current 16 A
Maximum continuous current 10 A
Maximum switching voltage 250 VDC, 440 VAC
Minimum switching voltage 12 V
Timing diagram Minimum switching current 10 mA
in Maximum contact resistance 15 mΩ
Material Ag standard
Maximum switching capacity and See curves on page 57
electrical life expectancy
out
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 190 g (with adjustable knob)
Operating temperature -25 °C...+70 °C
t pulse
t cycle Humidity 95 %
47
www.morssmitt.com
Flashing
Pulse specifications
Pulse function Flashing (symmetrical): duty cycle 1/2
Pulsing frequency 30 / 60 / 90 / 120 per minute
Options (other times on request)
Connection diagram
48
www.morssmitt.com
One-shot
WDE4-U200 10 A, 4 C/O
Plug-in electronic one-shot time railway relay with 4 change-over contacts.
When the relay is activated the coil is energized with 1 pulse.
Timing
in diagram Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 170 g (without options)
Operating temperature -25 °C...+70 °C
Humidity 90 %
out
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC)
WDE4-U201 24 16.8 30
on
WDE4-U202 48 33.6 60
WDE4-U203 72 50.4 90
Connection diagram WDE4-U204 110 77.0 138
WDE4-U205 96 67.2 120
WDE4-U207 36 25.2 45
Other types on request
49
www.morssmitt.com
One-shot
Nominal voltage
Type Unom (VAC) Hz Umin (VAC) Umax (VAC)
on WDE4-U301 24 50 19.2 28.8
WDE4-U302 220 50 176 264
WDE4-U303 110 50 88 132
Connection diagram
WDE4-U304 120 50 96 144
WDE4-U305 110 60 88 132
WDE4-U307 115 60 92 138
Other types on request
50
www.morssmitt.com
One-shot
PDF3-U200 10 A, 4 C/O
Plug-in electronic one-shot railway relay with 3 change-over contacts. The relay is
activated by the negative going edge of a DC voltage on the input terminals.
51
www.morssmitt.com
One-shot & instantaneous
52
www.morssmitt.com
One-shot & instantaneous
(WDDE-U200 shown)
Time delay specifications
Options Time delay function Instantaneous and one-shot
Available pulse times 0.1 s...60 min
• Low temperature (-40 OC)
Contact data
Amount and type of contacts 2 C/O instantaneous and 2 C/O time delay
Maximum make current 14 A
Maximum continuous current 8A
Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 100 mA
Material AgNi + 0.15 µm Au
Maximum switching capacity and See curves on page 58
electrical life expectancy
out-1s
WDDE-U306 240, 50 Hz 190 288
Other types on request
pulse
Connection diagram
53
www.morssmitt.com
Example ordering scheme D-platform
Each relay has its own ordering scheme. In this scheme all available possibilities for this relay is
mentioned and can be selected. On www.morssmitt.com all datasheets for all relays are available.
D-U3 03 - C
1. Relay model 2. Coil voltage 3. Options
1. Relay model
D-U3
2. Coil voltages
01 24 VAC / 50 Hz
03 220 VAC / 50 Hz
05 110 VAC / 50 Hz
07 380 VAC / 50 Hz
08 120 VAC / 60 Hz
09 110 VAC / 60 Hz
10 220 VAC / 60 Hz
13 230 VAC / 50 Hz
14 254 VAC / 60 Hz
15 440 VAC / 60 Hz
17 400 VAC / 60 Hz
18 288 VAC / 50 Hz
20 380 VAC / 60 Hz
3. Options
54
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• BD-U200
12.1
• DGG-U200
• DI-U900
• D-U200 52.5
• D-U300
• FDA-U200
• FDA-U300
• FDC-U200
• TDB2-U200
1
11
13
40
10
12
14
2
Dimensions (mm)
for relay type:
• D8-U200
• KDN-U200
• TDD4B2-U200
53.8
65.9
55
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• CTD4-U
• FDA4-U200
• FDC4-U200
• FDG-U200
• KCD-U200
• MTDV4-U200
• TDB4-U200
• TDBE-U200
• TDBE4-U200
• TDBE4-U300
• TDDB-U200
• TDDB-U300
• TDE3-U200
• TDE4N-U
• TDE-U200
• UMD-U200
• UMD-U300
• WDDE-U200
• WDDE-U300
• WDE4-U200
• WDE4-U300 without knob with knob
Dimensions (mm)
for relay type:
• PDF3-U200
• TDE4-U200
56
www.morssmitt.com
Electrical life expectancy
D-platform curves 1
AC current breaking capacity at cos φ = 1 AC current breaking capacity at cos φ = 0.7 ; 0.5 ; 0.3
Curves 1 3 5 6 7 8 9 11 12
VAC 24 24 125 220 24 125 220 125 220
AC Current breaking capacity Cos Ø 0.7 0.5 0.7 0.7 0.3 0.5 0.5 0.3 0.3
100.000
100.00
10.000
Millions of cycles
4
10.00 3
Millions of cycles
2
1.000
1 1
3
1.00
5
6
0.100 7
8
9
11
12
0.10
0.1 1 10
0.010
Amps 0.1 1 10
Amps
DC Current breaking capacity versus life expectancy in millions of cycles. DC Current breaking capacity versus life expectancy in millions of cycles.
Rate of contacts opening and closing = 1200 operations per hour.
Rate of contacts opening and closing = 1200 operations per hour.
Curves shown for inductive load -
Curves shown for resistive load (L/R = 0). Continuous current.
L/R = 20 ms continuous current
L/R = 40 ms continuous current
* By connecting 2 contacts in series, we increase the DC current breaking capacity by 50%
* By connecting 2 contacts in series, we increase the DC current breaking capacity by 50%
Curve 1 2 3 4
Curves 1 2 3 4 5 6 7 8
VDC 220 125 48 24
VDC 24 48 24 125 220 48 125 220
L/R (ms) 20 20 40 20 20 40 40 40
100
100.00
10
Millions of cycles
Millions of cycles
10.00
1
4
3
2
1 0.1 1
1.00 2
3
4
0.01 5
6
7
0.10
0.001 8
0.1 1 10
0.1 1 10
Amps
Amps
57
www.morssmitt.com
Electrical life expectancy
D-platform curves 2
Maximum breaking capacity Contact life
1 1.0
0.1 0.1
10 100 1000 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2
DC voltage (V) Breaking capacity (kVA)
58
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Rail mounting
V23 Screw socket, front connection (7.5 mm terminals)
V23BR Screw socket, front connection (9 mm terminals)
V29 Spring clamp socket, front dual connection (2.5 mm2)
PCB-mounting
V32 PCB-soldering socket
Suitable for
V26 V29 • BD-U200
• CTD4-U
• DGG-U200
• DI-U900
• D-U200
• D-U300
• FDA4-U200
• FDA-U200
• FDA-U300
V31 V32 • FDC-U200
• FDC4-U200
• FDG-U200
• KCD-U200
• MTDV4-U200
• PDF3-U200
• TDB2-U200
• TDB4-U200
• TDBE-U200
• TDBE4-U200
V33 • TDBE4-U300
• TDDB-U200
• TDDB-300
• TDE3-U200
• TDE4-U200
• TDE4N-U
• TDE-U200
• UMD-U300
• WDDE-U200
• WDDE-U300
• WDE4-U200
• WDE4-U300
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Rail mounting
V93 Screw socket, front connection (7.5 mm terminals)
V93BR Screw socket, front connection (9 mm terminals)
V99 Spring clamp socket, front dual connection (2.5 mm2)
PCB-mounting
For PCB-mounting use 2x V32 according pin lay-out
Suitable for
V93BR V96
• D8-U200
• KDN-U200
• TDD4B2-U200
V97 V99
2x V32
60
www.morssmitt.com
A- / B-platform
61
www.morssmitt.com
A- / B-platform
Design features
Plug-in design
Wide range of sockets for front or rear
mounting and connection types.
Weld-no-transfer contacts
Safety design counter blade system.
Relay always stays in a logic configura-
tion. For safety-critical applications.
Cover
Transparent cover for visual check.
Clear indication of type and contact Double make / break
arrangement.
Double arc extinction for high
inductive or capacitive loads.
Increasing electrical life. For
safety-critical applications
Cupro nickel ‘air gap’
To prevent magnetic sticking of mobile
armature to coil.
Contacts
Gold contacts or combined silver and
bifurcated gold contacts for dry circuit
applications
Flexible coupling
No friction of mobile armature,
extends mechanical life to 100 million
operations.
Coding keys
To prevent mount and replacement
error.
62
www.morssmitt.com
A- / B-platform
Options
Contacts are mechanically connected in such a way that N/C contacts and N/O
C Weld-no-transfer
contacts can never be closed at the same time.
- If a N/O contact fails to open and the relay de-energises, none of the N/C contacts closes
- If a NC contact fails to open and the relay energises, none of the NO contacts closes
G Goldplated contacts
Silver contacts with thin layer of gold to have a good resistance against corrosive
atmospheres. Suitable for switching low currents and low voltages.
Three silver contacts and one bifurcated gold contact. The bifurcated contact is
AM / Gold bifurcated and a two-contact finger design (contacts are in parallel) with wiping action to
BM silver contacts assure both lowest contact resistance and endurance.
V LED indicator
Built-in LED(s) to indicate the presence of power supply and the energizing
of the coil.
Key- Mechanical keying Positive mechanical keying relays to socket to prevent a relay being inserted
in a wrong socket.
ing relays to socket
63
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 4 double make / double break C/O contacts (form Z)
• Optional weld-no-transfer contacts for safety critical applications
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
Options 1 operation per minute
• Transil coil protection Minimum contact continuity 20 mA at 24 VDC
• Avalanche diode coil protection Number of contacts 4 double make / double break contacts (form Z)
• Weld-no-transfer Contact material Hard silver overlay laminated to copper
• LED coltage indicator
Contact resistance - initial 10 mΩ max at 5 A
• Relay cover for wire locking spring
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 108
Timing diagram
A4
EG 125
A4
88 / 156 3 73
A4
12 5700 30
B4 B4 B4
C4 C4 C4
D1 D1 Keying Unom (VAC) Uoperating
D1 (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) ms)
D2 D2 SZ 115 80 / 140
D2 3 65 10 4000 30
D3 D3 CG 220 176
D3 / 242 3 129 21 15000 30
D4 D4 (1) Coil resistance tolerance: D4
± 8 % at 20 °C (2) Valid for closed relay
Other types on request
VDC Models VDC Models VAC Models
(no Transil protection) (with Transil protection) N.B.: Transil not needed on VAC coil relays.
64
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 4 double make / double break C/O contacts (form Z), gold plated on silver
• Weld-no-transfer function optional
• Contacts cross pollution barrier
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Contact configuration 4 C/O double break contacts
Contact design Stationary contacts: 2 single contacts (contacts in series)
Options Movable contacts: solid blade
• Transil coil protection (only with 400 type) Maximum contact ratings Operating: 20 mA maximum at 72 VDC
• Avalanche diode coil protection Carry only (no make and break): 5 A maximum at 5 VDC
• Weld-no-transfer Minimum current ratings 10 mA at 12 VDC
• LED coltage indicator Contact material Stationary contacts: Gold plated over hard silver
• Relay cover for wire locking spring Moveable contacts: Gold over hard silver overlay
laminated to copper
Contact resistance < 20 mΩ at 5 A (carry only)
Timing diagram
Electrical life expectancy See curves on page 108
B4
A4
B4 Keying Unom (VAC)
A4 Uoperating
B4 (VAC) Pnom (VA) Uhold (VAC)
A4 Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) ms)
C4 C4 C4
D1 D1 SZ 115 80D1/ 140 3 65 10 4000 30
D2 D2
CG 220 176D2/ 242 3 129 21 15000 30
D3 D3 D3
(1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
D4 D4 Other types on request D4
65
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 4 double make / double break C/O contacts (form Z)
• Weld resistant
• Optional weld-no-transfer contacts for safety critical applicaitons
• Contact life (mechanical) of 100 million cycles
Contact data
Maximum continuous current 8A
Contact overload withstand At 24 VDC: 10 x 100 A at L/R = 0 for 10 ms,
Options
1 operation per minute
• Transil coil protection (only with 400 type) Minimum contact continuity 20 mA at 110 VDC & 100 mA at 24 VDC
• Avalanche diode coil protection Number of contacts 4 double make / double break contacts (form Y)
• Weld-no-transfer Contact material Stationary contacts: tin silver oxide (10 %)
• LED coltage indicator Movable contacts: hard silver overlay laminated to copper
• Relay cover for wire locking spring
Electrical life expectancy See curves on page 110
A3
Keying Unom A3
(VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) (ms)
A3
B3 B3 B3
C3
SZ 115
C3
80 / 140 3 65
C3 10 4000 30
A4 A4 A4
B4
C4
B4 CG 220
C4
176
B4 / 242 3 129
C4
21 15000 30
D1 D1 (1) Coil resistance tolerance: ±D18 % at 20 °C (2) Valid for closed relay
D2 D2 Other types on request D2
D3 D3 D3
D4 D4 D4
66
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 3 double make / double break C/O contacts (form Z) + 1 gold bifurcated C/O contact
• Weld-no-transfer contact for silver contacts optional
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
A3
FLZ 36
A3
25 / 45 3 21
A3
3.5 430 30
B3 B3 B3
C3 DGZ 48
C3 33 / 60 3 28.5
C3 4.5 750 30
A4* A4* A4*
B4*
C4*
B4* Keying UnomC4*
(VAC) Uoperating
B4* (VAC) Pnom (VA) Uhold
C4*(VAC) Udrop-out (VAC) Rcoil (Ω)
(1)
L/R (2) ms)
D1 D1 D1
SZZ 115 80 / 140 3 65 10 4000 30
D2 D2 D2
CGZ 220 176 / 242 3 129 21 15000 30
D3 D3
(1) Coil resistance tolerance: D3
± 8 % at 20 °C (2) Valid for closed relay
D4 D4 Other types on request D4
67
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous, safety-critical relay
• 4 double make / double break C/O contacts (form Z)
• Weld-no-transfer contacts standard
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 12 A
Contact overload withstand At 24 VDC: 10 x 200 A at L/R = 0 for 10 ms,
Options 1 operation per minute
• Transil coil protection Minimum contact continuity 20 mA at 24 VDC
• Avalanche diode coil protection Number of contacts 4 double make / double break contacts (form Z)
• LED coltage indicator Contact material Hard silver overlay laminated to copper
• Relay cover for wire locking spring
Contact resistance - initial 10 mΩ max at 5 A
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 112
Timing diagram
Mechanical & environmental characteristics
Mechanical life > 100 x 106 operations
Weight 450 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage & keying
Keying Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (VDC) Udrop-out (VDC) Rcoil (1)(Ω) L/R (2) (ms)
ME 12 8 / 16 3.5 6.25 1.25 40 40
Connection diagram (example) AG 24 16 / 33 3.5 13.5 2.5 170 40
FL 36 25 / 45 3.5 21 3.5 390 40
DG 48 33 / 60 3.5 28.5 4.5 625 40
B1
A1
B1 BG 72
A1
B148 / 90 3.5 40.5
A1 6.5 1600 40
C1 C1 C1
A2
US 96
A2
65 / 120 3.8 50
A2
9 2400 40
B2 B2 B2
C2 EG 115
C2 77 / 144 3.5 60
C2 11.5 4000 40
B3
A3
B3 FG 550
A3
400 / 660
B3 4 300
A3 50 75500 40
C3 C3 C3
A4
UT 700
A4
450 / 900 4.2 380
A4
60 115000 40
B4 B4 B4
C4 C4 C4
D1 D1 Keying Unom (VAC) Uoperating
D1 (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) ms)
D2 D2 EM 127 88 / 143
D2 4 71.5 12 4000 40
D3 D3 CG 220 176 / 242
D3 3 129 21 14350 30
D4 D4 D4
(1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
VDC Models Other types on request
VDC Models VAC Models
(no Transil protection) (with Transil protection) N.B.: Transil not needed on VAC coil relays.
68
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 4 double make / double break C/O contacts (form Z), gold plated on silver
• Weld-no-transfer function optional
• Contacts cross pollution barrier
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Contact configuration 4 C/O double break contact
Options Contact design Stationary contacts: 2 single contacts (contacts in series)
Movable contacts: solid blade
• Transil coil protection
Maximum contact ratings Operating: 20 mA maximum at 72 VDC
• Avalanche diode coil protection
Carry only (no make and break): 5 A maximum at 5 VDC
• Weld-no-transfer
• LED coltage indicator Minimum current ratings 10 mA at 12 VDC
• Relay cover for wire locking spring Contact material Stationary contacts: Gold plated over hard silver
Moveable contacts: Gold over hard silver overlay
laminated to copper
Timing diagram Contact resistance < 20 mΩ at 5 A (carry only)
Electrical life expectancy See curves on page 112
A3
US 96 A3 65 / 120 3.8 50A3 9 2400 40
B3 B3 B3
C3 EG 115C3 77 / 144 3.5 60C3 11.5 4000 40
B4
A4
C4
B4 FG 550A4
C4
440
B4 / 660 4 300A4 50 75500 40
C4
D1 D1 UT 700 450
D1 / 900 4.2 380 60 115000 40
D2 D2 D2
Keying Unom (VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) ms)
D3 D3 D3
D4 D4
EM 127 88D4/ 143 4 71.5 12 4000 40
CG 220 176 / 242 3 129 21 14350 40
VDC Models VDC Models VAC Models
(no Transil protection) (with Transil protection)
(1) Coil resistance tolerance: ± 8 % atN.B.:20Transil
°C not needed
(2)on Valid
VAC coil relays.
for closed relay
Other types on request
69
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous, safety-critical relay
• 4 double make / double break C/O contacts (form Z)
• Weld-no-transfer contacts standard
• Weld resistant
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 12 A
Contact overload withstand At 24 VDC: 10 x 200 A at L/R = 0 for 10 ms,
Options 1 operation per minute
• Transil coil protection Minimum contact continuity 20 mA at 110 VDC & 100 mA at 24 VDC
• Avalanche diode coil protection Number of contacts 4 double make / double break contacts (form Z)
• LED coltage indicator Contact material Stationary contacts: tin silver oxide (10 %)
• Relay cover for wire locking spring Movable contacts: hard silver overlay laminated to copper
Contact resistance - initial 30 mΩ max at 5 A
Contact resistance - end of life 60 mΩ max at 5 A
Electrical life expectancy See curves on page 114
Timing diagram
Mechanical & environmental characteristics
Mechanical life > 100 x 106 operations
Weight 450 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage & keying
Keying Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (VDC) Udrop-out (VDC) Rcoil (1)(Ω) L/R (2) (ms)
ME 12 8 / 16 3.5 6.25 1.25 40 40
Connection diagram (example) AG 24 16 / 33 3.5 13.5 2.5 170 40
FL 36 25 / 45 3.5 21 3.5 390 40
DG 48 33 / 60 3.5 28.5 4.5 625 40
A1 A1 A1
B1
C1
B1 BG 72
C1
B148 / 90 3.5 40.5
C1 6.5 1600 40
B2
A2
B2
US 96
A2 65 / 120
B2
3.8 50
A2 9 2400 40
C2 C2 C2
EG 115 77 / 144 3.5 60 11.5 4000 40
A3 A3 A3
B3
C3
B3
FG 550
C3 400 / 660
B3
4 300
C3 50 75500 40
B4
A4
B4 UT 700
A4 450 / 900
B4 4.2 380
A4 60 115000 40
C4 C4 C4
D1 D1 D1
Keying Unom (VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) ms)
D2 D2 D2
EM 127 88 / 143 4 71.5 12 4000 40
D3 D3 D3
D4 D4
CG 220 176 / 242
D4
3 129 21 15000 30
70
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous relay
• 3 double make / double break C/O silver contacts (form Z) & 1 gold bifurcated C/O contact
• Weld-no-transfer function for silver contacts
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
* A4, B4, C4: Gold bifurcated contact – All other contacts are Silver
71
www.morssmitt.com
Latching
SB Safety-critical, 8 A, 4 or 3 C/O
Latching, safety-critical railway relay with 2 stable magnetic latched states. When
1 coilis energized, the relay actuates from magnetical latched position 1 to 2. When
the other coil is energized, the relay actuates back to position 1.
• Plug-in design
• Latching relay using 2 seperate coils and magnetic rocker mechanism
• Type 400 with 4 C/O contacts, of type 300 with 3 C/O contacts
• All contacts are double make / double break contacts (form Z)
• Weld-no-transfer contacts optional
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Minimum contact continuity 20 mA at 24 VDC
Options Number of contacts Type 400: 4 double make / double break contacts (form Z)
• Transil coil protection (only with 400 type) Type 300: 3 double make / double break contacts (form Z)
• Weld-no-transfer Contact material Hard silver overlay laminated to copper
• Manual reset control lever Contact resistance - initial 10 mΩ max at 5 A
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 108
400 Contact Type Operation: 300 Contact Type Operation: 300 Contact Type Operation:
Type 400: 4 double make / double break contacts (form Z)
ended Tothat
operate
Type
this relay, it is recommended This
the coil
300:with3 double
that therelay
coilis designed for actuationThis of the Dimensions
relaycoilis with
designed
a See page 107
for actuation of the coil with a
ms min.be actuated
duration. a pulse make / double
of 50 ms permanent
min. break
duration. contacts
voltage. (form Z) the
After connecting permanent
negativevoltage.
terminalAfter connecting the negative terminal
is applied
Assumingto either
that before any voltage is applied of the
topower
either supply to terminal B4 and assuming
of the power Mounting possibilities & sockets See page 117
thatsupply
beforeto terminal B4 and assuming that before
The
A, operation
coil all 4th
contacts
is ascontact
are in is reserved
position forany
automatic
B-A, operation is as is coupling
voltage of the
applied to either coils.
coil, any
all contacts
voltage are is applied
in to either coil, all contacts are in
follows: Detailed information and datasheets available on www.morssmitt.com
position BA,operation is as follows; position BA,operation is as follows;
ls D1-D4,
Whenthe a signal
relay is applied to terminals D1-D4, When a positive signal from the powerWhen
the relay supply a positive
is applied signal
to from the power supply is applied to
all contacts
actuatesto and terminal
themagnet-ically latches all contacts D1, the relay actuates and magnetically
to the terminal D1, latches
the relay
all actuates and magnetically latches all
applied
B-C position.
to termi-A subsequent signal applied contacts
to termi- to the B-C position. Duringcontacts
this actuation,
to the B-C as position. During this actuation, as
ontacts nalsfrom
D2-D3 theiractuates the relay contactscontact
72B4-A4 switches to B4-C4, thecontact
from their powerB4-A4supply switches
is to B4-C4, the power supply is
ack to their formerlatched position B-C back to effectively
magnetically their formerdisconnected at positive terminaleffectively
D1 anddisconnected
a new at positive terminal D1 and a new
. Note that a pulselatched position B-A. Note connection
magnetically www.morssmitt.com
that a pulseis made at terminal D3 so that connection
power to is themade
relayat terminal D3 so that power to the relay
o operate
of 50 msthemin.
relayduration is required to operate coilthe
is ON only while B4-A4 is connected.
relay coil isAON
subsequent
only while B4-A4 is connected. A subsequent
gized and
at that
a time.only one coil can be energized at positive
a time.signal applied at terminal D3positiveactuates signal
the relay
applied at terminal D3 actuates the relay
Latching
Contact data
Maximum continuous current 12 A
Minimum contact continuity 20 mA at 24 VDC
Number of contacts 4 double make / double break contacts (form Z)
Options
Contact material Hard silver overlay laminated to copper
• Relay cover for wire locking spring Contact resistance - initial 10 mΩ max at 5 A
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 112
73
www.morssmitt.com
Timer
a4
b4
c4
Power suply (+)
d1
Timer input
d2
Coil
d3 Dimensions See page 107
Power suply (–)
d4 Timer
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
74
www.morssmitt.com
Timer
a4
b4
c4
Power suply (+)
d1
Timer input
d2
Coil
d3
d4 Timer
Dimensions See page 107
Power suply (–)
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
75
www.morssmitt.com
Timer
Timer input
d2 d2
Coil
Dip switch
76
www.morssmitt.com
Timer
Timer input
d2 d2
Coil
Dip switch
77
www.morssmitt.com
Timer
Timer input
d2 d2
Coil
Dip switch
d3 d3
d4 d4 Timer
Dimensions See page 106
Power suply (–)
Mounting possibilities & sockets See page 116
Detailed information and datasheets available on www.morssmitt.com
78
www.morssmitt.com
Timer
d3 d3
79
www.morssmitt.com
Timer
Timer input
d2
Coil
Dip switch
d3
Dimensions See page 107
d4 Timer
Power suply (–)
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
80
www.morssmitt.com
Timer
81
www.morssmitt.com
Timer
Timer input
d2
Coil
Dip switch
82
www.morssmitt.com
Timer
Connection diagram GR 12 8 / 16 3 40 30
GP 24 16 / 33 3 185 30
a1 HP 36 25 / 43 3 475 30
b1
Delay on pull-in
c1 JP 48 33 / 60 3 750 30
(dip switch 10 = ON)
d1 a2 KP 72 48 / 90 3 1700 30
b2
d2 c2 MP 96 65 / 120 3 3000 30
Timer input
d3 LP 110 75 / 138 3 4000 30
a3
d4 b3
Power suply (–) c3 (1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
AC versions and other types on request
a4
Delay on drop-out b4
(dip switch 10 = OFF) c4
Power suply (+)
d1 d1 Dimensions See page 107
Timer input
d2 d2
Coil Mounting possibilities & sockets See page 117
Dip switch
d3 d3
Detailed information and datasheets available on www.morssmitt.com
Power suply (–)
d4 d4 Timer
83
www.morssmitt.com
Timer
Timer input
d2 d2
Coil
Dip switch
d3 d3
d4 d4 Timer
Dimensions See page 107
Power suply (–)
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
84
www.morssmitt.com
Timer
85
www.morssmitt.com
Timer
86
www.morssmitt.com
Timer & instantaneous
Contact data
Maximum continuous current 6A
Number of contacts 2 simple break contacts (form Z)
Contact material Ag + 0.2 µm AU
Contact resistance 15 mΩ max
Electrical life expectancy See curves on page 108
a4
c4
b4
Command
d2
d4
Command -
d3 Module Dimensions See page 107
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
87
www.morssmitt.com
Timer & instantaneous
a3
c3
b3
a4
c4
b4
d1
88
www.morssmitt.com
Timer & instantaneous
a4
c4
b4
Command
d2
d4
Command -
d3 Module Dimensions See page 107
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
89
www.morssmitt.com
Timer & instantaneous
a3
c3
b3
a4
c4
b4
d1
d2
Dimensions See page 107
Power suply (–) Coil
Timer input
d4 Timer Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
90
www.morssmitt.com
One-shot
www.morssmitt.com
One-shot
Contact data
Maximum continuous current 8A
Contact overload withstand At 24 VDC: 10 x 100 A at L/R = 0 for 10 ms,
1 operation per minute
Minimum contact continuity 20 mA at 24 VDC
Number of contacts 4 double make / double break contacts (form Z)
Timing diagram
Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 5 A
Delay on pull-in Delay on drop-out
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 108
Pulse input
d2
Coil
Dimensions See page 107
Dip switch
d3
92
www.morssmitt.com
One-shot
d3
Detailed information and datasheets available on www.morssmitt.com
Power suply (–)
d4 Timer
93
www.morssmitt.com
Two-shot
Pulse input
d2
Coil
Dip switch
d3
d4 Timer
Dimensions See page 107
Mounting possibilities & sockets See page 117
Power suply (–)
94
www.morssmitt.com
Monitoring
Contact data
Maximum continuous current 1A
Number of contacts 2 change-over contacts (form Z)
Options Contact material Hard silver overlay laminated to copper
On request Contact resistance 10 mΩ max
Current measuring specifications
Current levels (In) 15 A...25 A (other version available)
Current accuracy -5%...+5% from In
Maximal shunt current 40 A
Mechanical & environmental characteristics
Weight < 400 g
Timing diagram Operating temperature -40 °C...+85 °C
Connection diagram
a3
b3
c3
a4
b4
c4
+
d2 S
Level measurement M+ H
d3 U
M– N
T
d1 d4
Power supply
+ voltage – voltage –
input input
95
www.morssmitt.com
Monitoring
Voltage
drop
Voltage
increase Level 1
tdb (1) 24 15 / 30 23 / 25
Level 1 tdb (1) 36 25 / 48 tdb (1)
tdb (1) 48 30 / 64 tdb (1)
tdb (1) 72 46 / 96 65 / 70
tdb (1) 110 70 / 140 87 / 95
t1 t2
(1) To be defined
Other types on request
Connection diagram
Level 1
D2 +V
D1 D4
+V Power supply -V
96
www.morssmitt.com
Monitoring
Level 1
Level 2
tdb (1) 24 15 / 30 23 / 25 22 / 25
Level 2
tdb (1) 36 25 / 48 tdb (1) tdb (1)
tdb (1) 48 30 / 64 tdb (1) tdb (1)
t1 t2 tdb (1) 72 46 / 96 65 / 70 63 / 68
tdb (1) 110 70 / 140 87 / 95 85 / 95
t1 t2 (1) To be defined
Other types on request
Connection diagram
Level 2
D3 +V
Level 1
D2 +V
D1 D4
+V Power supply -V
97
www.morssmitt.com
Monitoring
Connection diagram
Level 3
C4 +V
Level 2
D3 +V
Level 1
D2 +V
D1 D4
+V Power supply -V
Dimensions See page 107
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
98
www.morssmitt.com
Monitoring
Connection diagram
a1
b1
c1
a2
b2
c2
Level measurement
d1 d4
+V Power supply –V
Dimensions See page 107
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
99
www.morssmitt.com
Monitoring
AW 24 16 / 36 tdb (1)
BW 36 25 / 45 tdb (1)
tdb (1) 48 33 / 60 tdb (1)
tdb (1) 72 48 / 90 tdb (1)
t1 t2
EV 110 75 / 138 tdb (1)
(1) To be defined
Connection diagram Other types on request
a1
b1
c1
a2
b2
c2
Level measurement
d1 d4
+V Power supply –V
Dimensions See page 107
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
100
www.morssmitt.com
Monitoring
101
www.morssmitt.com
Flashing
a4
b4
c4
d1
Timer input
d2
Coil
Dip switch
d3
d4 Timer
Dimensions See page 107
Power suply (–)
Mounting possibilities & sockets See page 117
Detailed information and datasheets available on www.morssmitt.com
102
www.morssmitt.com
Flashing
103
www.morssmitt.com
Flashing
104
www.morssmitt.com
Example ordering scheme A- / B-platform
Each relay has its own ordering scheme. In this scheme all available possibilities for this relay is
mentioned and can be selected. On www.morssmitt.com all datasheets for all relays are available.
Configuration:
AG 400 24 AG S C V F 1
1. Relay model 2. Nominal 3. Keying 4. Coil 5. Weld 6. LED 7. Cover 8. Language
voltage OVP no transfer ind. type (test report)
1. Relay model
AG 400
2 & 3. Nominal voltage and keying
AG 24 VDC US 96 VDC
FKL 36 VDC SV 110 VDC
DG 48 VDC EG 125 VDC
BG 72 VDC
– No coil protection
P Avalance diode coil protection
S Transil coil protection (only with 400 type)
5. Weld-no-transfer option
6. LED indicator
– No LED
V LED voltage indicator
– French
1 English
2 Spanish
105
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• A 400
• AG 400
• AK 400
• AM 400
Used Used
with locking brackets with wire locking spring
locking brackets wire locking spring
Dimensions (mm)
for relay type:
• TEAU 400
• TELAU 400
Used Used
with locking brackets with wire locking spring
locking brackets wire locking spring
106
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• B 400
• BG 400
• BK 400
• BM 400
• NTBBOR 400
• SB
• T2CBBU 400
• T2CBLBU 400
• T2PBAU 400
• TBAA 400
• TBAR 400
• TBAU 400
• TBBAO 400
• TBBOR 400
• TBBU 400
• TBLAU 400
• TBLBU 400
• TBSBAO 400
Used Used
• TCBBU 400
with locking
locking brackets
brackets with wire
wire locking
locking spring
spring
• TFBBU 400
• THBBU 400
• TPBAU 400
• TPBAUN 400
• TPBBU 400
• TTBCA 200
• TTBCA 400
• TTBCR 200
• TTBCR 400
• UB 001
• UB15A002 25A
16A 24A
• UB
17A 003 23A
• UB
18A 200
19A
22A
21A
• UB A40020A
• UB C200
Shunt
Relay pin correspondence
1 2 3 4
a R S K L
a
Dimensions P
O
EU keying b
(mm)T
N
J
H
M
G
b
• IB 200
1 2 3 4
(rear view of relay shown)
107
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 1
30
4
20
20
10 3
15
5 10
Millions of Cycles
2 9
8
2,5 7
6
Millions of Cycles
8
5 3
1
4 6 7
1
3
2 5
0,5
1
2 4
1,5
0,2
1
0,1
0
0 0,2 0,25 0,5 1 2 3 4 5 6 8 10 12
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps Amps
* By connecting 2 contacts in series, DC current breaking capacity increases by 50 % Life expectancy: 2 Millions of Cycles
Curve 1 2 3 4 5 6
Curve 1 2 3 4 L/R= 0ms 15ms 20ms 40ms 60ms 100ms
VDC 220 125 48 24
220
210
200
20
190
15 180
170
10 160
9 150
8
140
7 1 2 3 4
6 130
Millions of Cycles
5 120
Volts
110 1
4
100
2
3 90
3
80
2 70 4
60
1,5
50
5
40
1
30
6
0 20
0,2 0,25 0,5 1 2 3 4 5 6 8 10 12
10
Amps
0
1 2 3 4 5 6 7 8 9 10 11 12
Amps
108
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 1
60
50
40
30
L ms
R 20
100
12
90
10
11
80
8.3A 10
70
5 5 9
4
Millions of Cycles
60 8
12A
50 2 2,5
3 6 7
40
1 16.6A
5
30
4
1
20 3
15 2
0,5
0 1
50 100 200 300 400 500 600 700
Watts
0,2
0,1
0
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
109
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 2
60
VDC 220 125 48 24
50
40
30
20
4
20
10
15
3
5 10
9
Millions of Cycles
8
2
7
2,5
6
Millions of Cycles
5
4
1
1 8
3 3
6 7
0,5
2
5
1,5 2
1 4
0,2
1
0
0,1 0,2 0,25 0,5 1 2 3 4 5 6 8 10 12
0 Amps
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
* By connecting 2 contacts in series, DC current breaking capacity increases by 50 % Life expectancy: 800,000 of Cycles
Curve 1 2 3 4 5 6
Curve 1 2 3 4 L/R= 0ms 15ms 20ms 40ms 60ms 100ms
VDC 220 125 48 24
220
210
200
20 190
180
15 170
160
10 150
9 140
8
7 130
6 120
Millions of Cycles
Volts
110 1
5
100
4 1 2 3 4 2
90
3
3 80
70 4
60
2
50
5
1,5 40
30
6
1 20
10
0
0,2 0,25 0,5 1 2 3 4 5 6 8 10 12 0
1 2 3 4 5 6 7 8 9 10 11 12
Amps
Amps
110
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 2
30
L ms
R 20
100
90
10
80 12
8.3A
70 11
5 5
4
Millions of Cycles
60 10
8
12A
50 2 9
2,5
3
40
1 16.6A
30 6 7
1
20
5
15
4
0,5 3
0 2
50 100 200 300 400 500 600 700
Watts 1
0,2
0,1
0
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
111
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 3
40
30 60
3
50
20
40
30
10
2 25
20
1
5 15
Millions of Cycles
Millions of Cycles
10 4 6 8
2,5 5
9
8
3
7
2 7
6
1
1 5
4
0,5 3
0,2 1,5
1
0,1
0
0 0,2 0,25 0,5 1 2 3 4 5 6 8 10 12
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps Amps
DC Current breaking capacity versus life expectancy in millions of cycles. Maximum contact breaking capacity versus voltage for a given L/R.
Rate of contacts opening and closing = 1200 operations per hour. Rate of contacts opening and closing = 600 operations per hour.
Curves shown for resistive load (L/R = 0). Continuous current. Curves shown for resistive load (L/R=0) and inductive loads. Continuous current.
* By connecting 2 contacts in series, DC current breaking capacity increases by 50 % Life expectancy: 2 Millions of Cycles
Curve 1 2 3 4 5 6
L/R= 0ms 15ms 20ms 40ms 60ms 100ms
Curve 1 2 3 4
VDC 220 125 48 24
280
270
260
250
60 240
4
50 230
40 220
210
30 200
3
25 190
20 180
2 170
15 160
1
Millions of Cycles
150
Volts
1
10 140
9
8 130
7
2
120
6 3
110
5 100 4
4 90
80
3 70
5
60
2 50
40
1,5
30
6
20
1
10
0 0
0,2 0,25 0,5 1 2 3 4 5 6 8 10 12 1 2 3 4 5 6 7 8 9 10 11 12 13
Amps Amps
112
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 3
60
50 12
40
30
11
L ms 20
R 10
100 9
10
90
8
8.3A
80
5 7
5
70 6
Millions of Cycles
5
60 4
3 2,5
4
50
1 2 8.3A 3
40
10.4A 1
30 2
20
15 0,5
1
0
50 100 200 300 400 500 600 700
0,2
Watts
0,1
0
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
113
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 4
AC Current breaking capacity versus life expectancy in millions of cycles. DC Current breaking capacity versus life expectancy in millions of cycles.
Rate of contacts opening and closing = 1200 operations per hour. Rate of contacts opening and closing = 1200 operations per hour.
Curves shown for resistive (Power factor = 1) Curves shown for inductive load -
L/R = 20 ms continuous current
Curves 1 2 3 4 L/R = 40 ms continuous current
VAC 220 125 48 24
* By connecting 2 contacts in series, DC current breaking capacity increases by 50%
Curves 1-3 2-4 5-7 6-8
Vcc 220 Curves
125 48 241-3 2-4 5-7 6-8
60
50 VDC 220 125 48 24
40 4
30
60
20 50
3
40
10 30
25
2 20
Millions of Cycles
5
15
1
Millions of Cycles
2.5 10 6 8
4 5
9
8
3
7
2 7
6
1
1 5
4
0.5 3
0.2 1,5
1
0.1
0
0 0,2 0,25 0,5 1 2 3 4 5 6 8 10 12
1 1.5 2 2.5 3 4 5 6 7 8 10 12 Amps
Amps
* By connecting 2 contacts in series, DC current breaking capacity increases by 50% Life expectancy: 800,00 cycles
Curve 1 2 3 4
Vdc 220 Curves
125 48 24
1 2 3 4 Curves 1 2 3 4 5 6
VDC 220 125 48 24 L/R= 0 ms 15 ms 20 ms 40 ms 60 ms 100 ms
280
270
60
260
50
4 250
40 240
230
30
3 220
25 210
20 200
190
2
15 180
Millions of Cycles
1 170
10 160
9 150
Volts
8 1
140
7
130
6 2
120
5 3
110
4
100 4
90
3
80
70
2 5
60
50
1,5
40
30
1 6
20
0 10
0,2 0,25 0,5 1 2 3 4 5 6 8 10 12 0
1 2 3 4 5 6 7 8 9 1 0 11 12 13
Amps
Amps
114
www.morssmitt.com
Electrical life expectancy
A- / B-platform curves 4
Maximum power interuption versus load time constant (L/R) for a given voltage AC current breaking capacity versus life expectancy in millions of cycles.
Curves shown for resistive load I = P/V Rate of contacts opening and closing = 1200 operations per hour.
Values shown for inductive loads:
Cos Ø = 0.7
Cos Ø = 0.5
Cos Ø = 0.3
Cos Ø = 0.7
Cos Ø = 0.5
Curves 1 2 3 4 5 Cos ØCurves
= 0.3 1, 3 & 5 2,4&6 6, 9 & 10 8, 11 & 12
VDC 220 125 72 48 24 VAC 220 125 48 24
60
50 12
60 40
50
L ms 12
30
R 40
11
100 30
20
11 10
20
90 10
9
8.3A 9
80 10
5 10 8
70 8
7
7
60 5
5
6
Millions of Cycles
3 4 6
50 Millions of Cycles 5 5
1 2 4 4
8.3A 2,5 2,5
40
10.4A
3 3
30
1
20 1 2
15 2
0,5
0,5 1
0 W
50 100 200 300 400 500 600 700 1
0,2
0,2
0,1
0
1 0,1 1,5 2 2,5 3 4 5 6 7 8 10 12
0 Amps
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
115
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Suitable for
• A 400
• AG 400
EA 104 A EA 112 AF • AK 400
• AM 400
Suitable for
EA 104 E EA 112 EF • TEAU 400
• TELAU 400
Suitable for
• IB 200
EA 103 BFD
Detailed information and datasheets available on www.morssmitt.com
116
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Suitable for
• B 400
• BG 400
EA 104 B EA 111 • BK 400
• BM 400
• NTBBOR 400
• T2CBBU 400
• T2CBLBU 400
• T2PBAU 400
• TBAA 400
• TBAR 400
• TBAU 400
EA 112 BF • TBBAO 400
• TBBOR 400
• TBBU 400
• TBLAU 400
• TBLBU 400
• TBSBAO 400
• TCBBU 400
• TFBBU 400
• THBBU 400
• TPBAU 400
• TPBAUN 400
• TPBBU 400
• TTBCA 200
• TTBCA 400
• TTBCR 200
• TTBCR 400
• UB 001
• UB 002
• UB 003
• UB 200
• UB A400
• UB C200
www.morssmitt.com
118
www.morssmitt.com
CU-platform
119
www.morssmitt.com
CU-platform
Design features
Weld-no-transfer contacts
Safety design counter blade system.
Relay always stays in a logic configura-
Cover tion. For safety-critical applications.
Contacts
Up to 2 change-over contacts.
Standard Ag contact material.
Goldplated contact material on
request. Calibrated contact pressure.
Keying
Plug-in or PCB design Optional positive mechanical keying
Wide range of sockets for front or rear relay to socket
mounting and connection types
120
www.morssmitt.com
CU-platform
Options
The CU-relays (and derived models) can be equipped with many options. The concept allows composing the
CU-relays to almost any solution, however not all options or combinations are possible. Check possible
options and combinations with our sales department.
E Goldplated contacts
Silver contacts with thin layer of gold to have a good resistance against corrosive
atmospheres. Suitable for switching low currents and low voltages.
D Low operating voltage The relay has a large pull-in voltage range of 40% - 125% of the nominal voltage.
Lg LED green
Built-in green LED to indicate the presence of power supply and the energising
of the coil.
Lr LED red
Built-in red LED to indicate the presence of power supply and the energising
of the coil.
Key- Mechanical keying Positive mechanical keying relays to socket to prevent a relay being inserted
ing relays to socket in a wrong socket.
121
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 2 C/O
Maximum make current 15 A
Options Maximum continuous current 6A
• Gold plated contacts Maximum switching voltage 300 VDC (then max. current = 300 mA)
• LED (green or red) 250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page133
maximum switching capacity
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 40 g
Operating temperature -40 °C...+70 °C
Humidity 95 % (condensation is permitted temporarily)
Timing diagram Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil *(Ω)
CU/CP-U201-G 24 16.8 30 9.2 1550
CU/CP-U202-G 48 33.6 60 18.4 6306
CU/CP-U203-G 72 50.4 90 27.7 12887
CU/CP-U204-G 110 77 137.5 42.2 22630
CU/CP-U205-G 96 67.2 120 36.9 22630
CU/CP-U206-G 12 8.4 15 4.6 300
CU/CP-U207-G 36 25.2 45 13.8 2500
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
Connection diagram
122
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 2 C/O
Options Maximum make current 15 A
Maximum continuous current 6A
• Gold plated contacts
Maximum switching voltage 300 VDC (then max. current = 300 mA)
• LED (green or red)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 133
maximum switching capacity
Connection diagram
123
www.morssmitt.com
Instantaneous
Contact data
Number and type of contacts 2 C/O
Options Maximum make current 10 A
Maximum continuous current 8A
• Gold plated contacts
Maximum switching voltage 300 VDC (then max. current = 300 mA)
• Double make / double break contact (1 C/O)
250 VAC (then max. current = 2.6 A)
• LED (green or red)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag
Electrical life expectancy and See curves on page 134
maximum switching capacity
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil *(Ω)
CU/CP-U201-B 24 16.8 30 2.4 600
CU/CP-U202-B 48 33.6 60 4.8 2500
CU/CP-U203-B 72 50.4 90 7.2 4739
CU/CP-U204-B 110 77 137.5 11 12887
CU/CP-U205-B 96 67.2 120 9.6 9647
CU/CP-U206-B 12 8.4 15 1.2 165
CU/CP-U207-B 36 25.2 45 3.6 1550
Connection diagram CU/CP-U210-B 120 84 150 12 15371
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
124
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 1 C/O + 1 N/O
Options Maximum make current 15 A
• Gold plated contacts Maximum continuous current 6A
• LED (green or red) Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 133
maximum switching capacity
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil * (Ω)
CU/CP-U201-D 24 9.6 30 9.2 1550
CU/CP-U202-D 48 19.2 60 18.4 6306
CU/CP-U203-D 72 28.8 90 27.7 12887
CU/CP-U204-D 110 44 137.5 42.2 22630
CU/CP-U205-D 96 38.4 120 36.9 22630
CU/CP-U206-D 12 4.8 15 4.6 390
Connection diagram CU/CP-U207-D 36 14.4 45 13.8 3300
CU/CP-U210-D 120 48 150 6.0 22630
125
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 1 double make / double break
Maximum make current 15 A
Options
Maximum continuous current 8A
• Gold plated contacts Maximum switching voltage 300 VDC (then max. current = 300 mA)
• LED (green or red) 250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 135
maximum switching capacity
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 40 g
Operating temperature -40 °C...+70 °C
Humidity 95 % (condensation is permitted temporarily)
Connection diagram
126
www.morssmitt.com
Instantaneous
Contact data
Amount and type of contacts 1 double make / double break
Options Maximum make current 15 A
Maximum continuous current 8A
• Gold plated contacts
• LED (green or red) Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 135
maximum switching capacity
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 40 g
Operating temperature -40 °C...+70 °C
Timing diagram Humidity 95 % (condensation is permitted temporarily)
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Udrop-out (VDC) Rcoil *(Ω)
CU/CP-U301-U 24 16.8 30 8.4 221
CU/CP-U310-U 220 154 275 77 15371
CU/CP-U311-U 115 80.5 144 40.3 2500
* The Rcoil is measured at room temperature and has a tolerance of + 10 %
Other types on request
Connection diagram
127
www.morssmitt.com
Latching
Contact data
Number and type of contacts 2 C/O
Maximum make current 15 A
Options Maximum continuous current 6A
Maximum switching voltage 300 VDC (then max. current = 300 mA
• Magnetic arc blow-out 250 VAC (then max. current = 2.6 A)
• Low temperature (-40 OC)
Minimum switching voltage 12 V (5 V with gold plated contacts)
• Gold plated contacts
• Double make / double break Minimum switching current 10 mA (1 mA with gold plated contacts)
Contact resistance 15 mΩ (initial)
Material Ag standard (optional Au on Ag)
Electrical life expectancy See curves on page 133
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 75 g
Operating temperature -25 °C...+70 °C (with option -40 oC)
Humidity 90 %
Nominal voltage
Type Unom (VDC) Umin (VDC) Umax (VDC) Rcoil * (Ω) Inom (mA)
Timing diagram
KCD-U201 24 16.8 30 500 48
KCD-U202 48 33.6 60 2060 23
KCD-U203 72 50.4 90 3200 15
-- 110** 77.0 137.5 * 12
KCD-U205 96 67.2 120 7800 12
KCD-U206 12 8.4 15 137 88
KCD-U207 36 25.2 45 1300 29
Connection diagram
128
www.morssmitt.com
Monitoring
Contact data
Amount and type of contacts 1 C/O + 1 N/O
Option Maximum make current 15 A
• Suitable for non-sinusoisal currents (AC only) Maximum continuous current 6A
• Gold plated contacts Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 133
maximum switching capacity
Connection diagram
129
www.morssmitt.com
Monitoring
Contact data
Amount and type of contacts 1 C/O
Maximum make current 15 A
Option Maximum continuous current 6A
• Suitable for non-sinusoisal currents (AC only) Maximum switching voltage 300 VDC (then max. current = 300 mA)
• Gold plated contacts 250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V (5 V with gold plated contacts)
Minimum switching current 10 mA (1 mA with gold plated contacts)
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 133
maximum switching capacity
Mechanical & environmental characteristics
Mechanical life 30 x 106 operations
Weight 40 g
Operating temperature -40 °C...+70 °C
Humidity 95 % (condensation is permitted temporarily)
130
www.morssmitt.com
Example ordering scheme CU-platform
Each relay has its own ordering scheme. In this scheme all available possibilities for this relay is
mentioned and can be selected. On www.morssmitt.com all datasheets for all relays are available.
Example: CU-relay
CU-U2 04 - B U
1. Relay model 2. Coil voltage 3. Relay type 4. Options
1. Relay model
2. Coil voltages
01 24 VDC
02 48 VDC
03 72 VDC
04 110 VDC
05 96 VDC
06 12 VDC
07 36 VDC
10 120 VDC
3. Relay type
4. Options
131
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type: 30
• CU/CP-U200-G
• CU/CP-U300-G
• CU/CP-U200-B
34
• CU/CP-U200-D
• CU/CP-U200-U
• CU/CP-U300-U
• CU/CP-U900-D
• CU/CP-U900-I Ø 1.45 + 0.45
pitch 5
Dimensions (mm)
for relay type:
• KCS/KCP-U200
132
www.morssmitt.com
Electrical life expectancy
CU-platform curves 1
Maximum switching capacity Electrical life expectancy
MaxMax
Switching Capacity
Switching Capacity Contact LifeLife
Contact
1000 100
1000 100
2 contacts
Watt
2 contacts
in serie
in serie
100 10
100 10
DC inductive
DC inductive
DC DC
1 contact
1 contact
10 1
10 1
10 100 1000 0,10 1,00 10,00 100,00
10 100 1000 0,10 1,00 10,00 100,00
6
Volt Volt No ofNo
ops
of (x10 ) 6)
ops (x10
Step 2 Select the maximum switching capacity (in Watt) at this voltage in graph ‘Maximum switching capacity’
Step 3 Calculate the actual switched load (in Watt) out of the application
133
www.morssmitt.com
Electrical life expectancy
CU-platform curves 2
Maximum switching capacity Electrical life expectancy
Maximum switching capacity Electrical life expectancy
1000 100
10000
I max = 8 Amp
AC -r
60-i2
DC
I max = 8 Amp
DC -i2 : 2 contacts in s eries
100 10
DC -i
Imax AC -r : AC res is tive
DC -i : DC inductive (L/R =15ms )
AC -r or light bulbs
1000
10 AC -i2 : 2 contacts in s eries
10 100 1000
DC inductive
AC -i2 Voltage [V] AC -i : AC inductive (cos phi=0.7)
or light bulbs
AC -i
I max = 8 Amp DC -r2 : 2 contacts in s eries
DC -r2
100
Imax AC -r : AC res is tive DC -r : DC res is tive (max 300 V )
DC -r
AC -r 60-i2
DC
AC -i2 : 2 contacts in s eries DC -i2 : 2 contacts in s eries
DC -i
AC -i2 AC -i : AC inductive (cos phi=0.7) DC -i : DC inductive (L/R =15ms )
or light bulbs or light bulbs
AC -i
10
DC -r2 : 2 contacts in s eries 1
10 100 10 1000
DC -r2
Voltage [V] 10 100 1000 0.10 1.00 10.00 100.00
DC -r : DC res is tive (max 300 V )
DC -r
No of operations (x 106)
60-i2
DC
DC -i2 : 2 contacts in s eries
Voltage (V)
DC -i
DC -i : DC inductive (L/R =15ms )
or light bulbs
Step 1 Determine switching voltage out of the application
100 1000
Voltage [V]
Step 2 Select the maximum switching capacity (in Watt) at this voltage in graph ‘Maximum switching capacity’
Step 3 Calculate the actual switched load (in Watt) out of the application
134
www.morssmitt.com
Electrical life expectancy
CU-platform curves 3
Power( W)
100 100 10 10
DC inductive
DC inductive
10 10 1 1
10 10 100 100 1000 1000 0.10 0.10 1.00 1.00 10.00 10.00 100.00 100.00
Voltage Voltage
(V) (V) No of operations (x 106) (x 106)
No of operations
Step 2 Select the maximum switching capacity (in Watt) at this voltage in graph ‘Maximum switching capacity’
Step 3 Calculate the actual switched load (in Watt) out of the application
135
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Rail mounting
V17 Cage clamp socket, front connection (2.5 mm2)
V17-D Cage clamp, with back EMF-diode, front connection (2.5 mm2)
V17-Q1 Cage clamp, double zener diode 12 V...30 V, front connection (2.5 mm2)
V17-Q2 Cage clamp, double zener diode 30 V...45 V, front connection (2.5 mm2)
V17-Q3 Cage clamp, double zener diode 45 V...65 V, front connection (2.5 mm2)
V17-Q4 Cage clamp, double zener diode 65 V...90 V, front connection (2.5 mm2)
V17-Q5 Cage clamp, double zener diode 90 V...150 V, front connection (2.5 mm2)
V18
PCB mounting
V18 PCB-soldering socket equipped with retaining clip
Suitable for
• CU/CP-U200-B
• CU/CP-U200-D
• CU/CP-U200-G
• CU/CP-U300-G
• CU/CP-U200-U
• CU/CP-U300-U
• CU/CP-U900-D
• CU/CP-U900-I
Remark: V16, V17 and V18 are also available with 1 retaining clip.
136
www.morssmitt.com
C-platform
137
www.morssmitt.com
C-platform
Design features
Silver tin oxide option, resist to Gold contact optional for dry circuit
welding for inductive or capacitive applications
loads and safety-critical applications.
Weld-no-transfer contacts
Safety design counter blade system.
Relay always stays in a logic configura-
tion. For safety-critical applications.
Cover
Transparent cover for visual check.
Double make / break
Clear indication of type and contact
arrangement. Double arc extinction for high
inductive or capacitive loads.
Increasing electrical life. For
safety-critical applications
138
www.morssmitt.com
C-platform
Options
Contacts are mechanically connected in such a way that N/C contacts and N/O
C Weld-no-transfer
contacts can never be closed at the same time.
- If a N/O contact fails to open and the relay de-energises, none of the N/C contacts closes
- If a NC contact fails to open and the relay energises, none of the NO contacts closes
G Goldplated contacts
Silver contacts with thin layer of gold to have a good resistance against corrosive
atmospheres. Suitable for switching low currents and low voltages.
Three silver contacts and one bifurcated gold contact. The bifurcated contact is
Gold bifurcated and
CM silver contacts
a two-contact finger design (contacts are in parallel) with wiping action to
assure both lowest contact resistance and endurance.
V LED indicator Built-in LED(s) to indicate the presence of power supply and the energizing of the coil
Key- Mechanical keying Positive mechanical keying relays to socket to prevent a relay being inserted
ing relays to socket in a wrong socket.
DC / Suitable for both DC Relay coil with rectifier circuit to make the relay suitable for both DC and AC
AC and AC
139
www.morssmitt.com
Instantaneous
Contact data
Maximum continuous current 8 A resistive
Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
Options 1 operation per minute
• Transil coil protection Minimum contact continuity 20 mA at 24 VDC
• Avalanche diode coil protection Number of contacts 9 double make / double break contacts (form X & Y)
• LED coltage indicator Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 5 A
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 149
Timing diagram Mechanical & environmental characteristics
Mechanical life > 100 x 106 operations
Weight 400 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (VDC) Udrop-out (VDC) Rcoil (1)(Ω) L/R (2) (ms)
24 16 / 33 4.8 13.5 2.5 120 25
36 25 / 45 4.8 21 3.5 270 25
48 33 / 60 4.6 28.5 4.5 500 25
Connection diagram (example)
72 48 / 90 5.2 40.5 6.5 1000 25
100 67 / 125 5 57 9 2000 25
A0 A0 110 77 / 138 5 60 11.5 2400 25
(1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
B0 B0 Other types on request
4 N/C - 5 N/O 9 N/O
A1 B1 A1 B1
A2 B2 A2 B2
A3 B3 A3 B3
A4 B4 A4 B4
C0 D0 C0 D0
C1 D1 C1 D1
C2 D2 C2 D2
C3 D3 C3 D3
C4 D4 C4 D4
Schematic #2 Schematic #3
A0 A0
Contact data
Number of contacts 9 double make / double break contact (Form X & Y)
Options Maximum contact ratings Operating: 20 mA maximum at 72 VDC
Carry only (no make and break): 5 A maximum at 5 VDC
• Transil coil protection Minimum current ratings 10 mA at 12 VDC
• Avalanche diode coil protection
Contact design Stationary contacts: 2 single contacts (contacts are in series)
• LED coltage indicator
Moveable contacts: Solid blade
Contact material Stationary contacts: Gold plated over hard silver
Moveable contacts: Gold over hard silver overlay laminated
to copper
Timing diagram Contact resistance < 20 mΩ at 5 A (carry only)
Electrical life expectancy See curves on page 149
2 N/C - 7 N/O
110
4 N/C - 5 N/O
77 / 138 5
9 N/O
60 11.5 2400 25
A1 B1 A1 B1 A1 B1
A2 B2 A2 Unom (VAC)B2 Uoperating (VAC)
A2 Pnom (VA) Uhold
B2 (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) (ms)
A3 B3 A3 B3 A3 B3
A4
C0
B4
D0
A4
C0
220 B4
D0
176 / 242 A4
C0
4 129
B4
D0
21 12000 25
C1 D1 C1 D1 C1 D1
C2 D2 C2
(1) Coil resistance tolerance: ± 8 % at 20 °C
D2 C2
(2) Valid for closed relay
D2
C3 D3 C3 Other types on request
D3 C3 D3
C4 D4 C4 D4 C4 D4
A0 shown with A0 A0
Transil Protection
option
B0 B0 B0
Contact data
Maximum continuous current 8A
Options Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
1 operation per minute
• Transil coil protection
Minimum contact continuity 20 mA at 110 VDC and 100 mA at 24 VDC
• Avalanche diode coil protection
• LED coltage indicator Number of contacts 9 double make / double break contacts (form X & Y)
Contact material Stationary contacts: tin oxide (10 %)
Mobile contacts: hard silver overlay laminated to copper
Contact resistance - initial 30 mΩ max at 5 A
Contact resistance - end of life 60 mΩ max at 5 A
Timing diagram Electrical life expectancy See curves on page 151
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (VDC) Udrop-out (VDC) Rcoil (1)(Ω) L/R (2) (ms)
24 16 / 33 4.8 13.5 2.5 120 25
Connection diagram (example)
36 25 / 45 4.8 21 3.5 270 25
48 33 / 60 4.6 28.5 4.5 500 25
72 48 / 90 5.2 40.5 6.5 1000 25
A0 A0
110 77 / 138 5 60 11.5 2400 25
B0 B0
Unom (VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) Rcoil (1)(Ω) L/R (2) (ms)
4 N/C - 5 N/O 9 N/O220 176 / 242 4 129 21 12000 25
A1 B1 A1 B1
A2 B2 A2 (1) Coil resistance
B2 tolerance: ± 8 % at 20 °C (2) Valid for closed relay
A3 B3 A3 Other types onB3request
A4 B4 A4 B4
C0 D0 C0 D0
C1 D1 C1 D1
C2 D2 C2 D2
C3 D3 C3 D3
C4 D4 C4 D4
Schematic #2 Schematic #3
A0 A0
Dimensions See page 148
Mounting possibilities & sockets See page 153
B0 B0
Detailed information and datasheets available on www.morssmitt.com
3 N/C - 6 N/O 7 N/C - 2 N/O
A1 B1 A1 B1
A2 142 B2 A2 B2
A3 B3 A3 B3
A4
C0
www.morssmitt.com
B4
D0
A4
C0
B4
D0
C1 D1 C1 D1
Instantaneous
• Plug-in design
• Instantaneous relay for combined power & dry circuit applications in diesel locomotives
• 4 N/C + 5 N/O double break silver contacts with 1 N/O & 1 N/C gold bifurcated contacts
• Weld-no-transfer contacts standard on silver contacts
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Nominal voltage
A1 B1
A2
A3
B2
B3
Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (VDC) Udrop-out (VDC) Rcoil (1)(Ω) L/R (2) (ms)
A4, B4 Gold
A4 B4
C4, D4 Gold C0 D0 72 48 / 90 5.2 24 6.5 1000 25
All other contacts Silver C1 D1
C2 D2
C3 D3
C4 D4
(1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
Other types on request
4 NC contacts- 5 NO contacts
143
www.morssmitt.com
Latching
• Plug-in design
• Latching relay using 2 seperate coils and magnetic rocker mechanism
• 8 N/O and N/C contacts in various combinations
• Weld-no-transfer contacts standard
• Contact life (mechanical) of 50 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
Options 1 operation per minute
• Transil coil protection Minimum contact continuity 20 mA at 24 VDC
Number of contacts 8 N/O and N/C contacts in various combinations
Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 5 A
Contact resistance - end of life 40 mΩ max at 5 A
Electrical life expectancy See curves on page 149
Timing diagram
Mechanical & environmental characteristics
Mechanical life > 50 x 106 operations
Weight 500 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) Rcoil (1)(Ω) L/R (2) (ms)
24 18 / 33 3 200 + 8 % 30
72 50 / 90 3 1800 + 8 % 30
Connection diagram (example) 110 77 / 138 3 4000 + 8 % 30
(1) Coil resistance tolerance: ± 8 % at 20 °C (2) Valid for closed relay
Schematic #1 SchematicOther
#2 types on request Schematic #3
044 Contact Type 035 Contact Type 033 Contact Type
(in "trip" position) (in "trip" position) (in "trip" position)
A0 A0 A0
D1 Coil 1 D1 Coil 1 D1 Coil 1
B0 COIL(set)
1
B0 (set) B0 (set)
A1 B1 A1 B1 A1 B1
A2 B2 A2 B2 A2 B2
A3 B3 A3 B3 A3 B3
C0 D0 C0 D0 C0 D0
C1 D1 C1 D1 C1 D1
C2 D2 C2 D2 C2 D2
C3 D3 C3 D3 C3 D3
C4 D4 C4 D4 C4 D4
Increasing & decreasing threshold voltage diagrams in datasheet tbd (1) 24 16 / 330 tbd (1)
reasing threshold voltage Decreasing threshold voltage
VDC
tbd (1) 36 25 / 45 tbd (1)
Connection diagram
Threshold Battery voltage Threshold
145
www.morssmitt.com
Flashing
• Plug-in design
• Solid state outputs
• One or two independent output channels
• Flashing frequency varies according series
• Secure locking feature for maximum ease of maintenance
Electrical characteristics
1019 C D E F G H J K L M
Flashing rate T (1/min) 120 120 120 120 120 120 10 120 360 120
Options Switching on time T1 (s) 0.2 0.17 0.17 0.2 0.17 0.17 0.17 0.17 0.08 0.2
Interval time (s) 0.3 0.33 0.33 0.3 0.33 0.33 0.33 0.33 0.08 0.3
On request
Independent channels 1 1 2 2 2 2 2 2 1 1
Light bulbs to connect 2 2 4 4 4 4 2* 2 1 2
Operating voltage range (VDC) 16-33 50-90 50-90 16-33 50-90 16-33 8-16 16-33 50-90 70-138
Nominal voltage light bulbs (VDC) 24 72 72 24 72 24 12 24 72 100
Keying 58 34 11A 158 311 5F tbd 48B 48C 49E
Power light bulbs (W) 55-50 55-18 50-18 55-50 50-18 55 55 55-18 2 55
Maximum power (W) 115 68 2x 68 2x 115 2x 68 2x 115 70 68 68 68
* 2 + pilot light
Timing diagram (example)
Flashing delay
Mechanical & environmental characteristics
1019C Weight 300 g
Operating temperature -25 °C...+70 °C
Humidity 93 % RH, 40 oC for 4 days
T1= 2/5T
1019C
Command
Static
relay
146
www.morssmitt.com
Example ordering scheme C-platform
Each relay has its own ordering scheme. In this scheme all available possibilities for this relay is
mentioned and can be selected. On www.morssmitt.com all datasheets for all relays are available.
Example: C-relay
CM 045 72 37 S V 1
1. Relay model 2. Basic part number* 3. Coil 4. LED 5. Language
OVP indicator (test report)
1. Relay model
CM
2. Relay basic part number*
– No coil protection
P Avalanche diode coil protection
S Transil coil protection
– No LED
V LED voltage indicator
– French
1 English
2 Spanish
Keying code
Nominal voltage
Number of N/O contacts
Number of N/C contacts
Number of C/O contacts
147
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• C
• CG
• CK
• CM
• SC
• UTC
• 1019
148
www.morssmitt.com
Electrical life expectancy
C-platform curves 1
AC Current breaking capacity versus life expectancy in millions of cycles. DC Current breaking capacity versus life expectancy in millions of cycles.
Rate of contacts opening and closing = 1200 operations per hour. Rate of contacts opening and closing = 1200 operations per hour.
Curves shown for resistive load (Power Factor = 1). Curves shown for inductive load:
L/R= 20 ms continuous current
Curve 1 2 3 4 L/R= 40 ms continuous current
VAC 220 125 48 24
40
30 60
3
50
20
40
30
10
2
25
20
1
5 15
Millions of Cycles
Millions of Cycles
10 4 6 8
5
2,5 9
8
3
7
2 7
6
1
5
1
4
3
0,5
1,5
0,2
0
0,1 0,15 0,2 0,4 0,75 1 1,5 2 3 4 4,5 6 7,5 9
0
0,75 1 1,5 2 2,5 3 3,5 4 4,5 5 6 7,5 9 Amps
Amps
Curve 1 2 3 4 5 6
Curve 1 2 3 4 L/R= 0ms 15ms 20ms 40ms 60ms 100ms
VDC 220 125 48 24
280
270
260
250
60 240
4
50 230
40 220
210
30
3 200
25 190
20 180
2
170
15
1 160
Millions of Cycles
150
Volts
10 1
9 140
8
130
7 2
120
6 3
110
5
100 4
4
90
3 80
70
5
2 60
50
1,5
40
30
1 6
20
0 10
0,15 0,2 0,4 1 1,5 2 3 4 4,5 6 7,5 9
0
Amps 0,75 1,5 2,25 3 3,75 4,5 5,25 6 6,75 7,5 8,25 9 9,75
149
www.morssmitt.com
Electrical life expectancy
C-platform curves 1
60
50 12
40
30
11
20
10
9
10
8
7
5
6
Millions of Cycles
5
4
2,5
1
2
0,5
1
0,2
0,1
0
0,75 1 2 2,5 2,5 3 3,5 4 4,5 5 6 7,5 9
Amps
150
www.morssmitt.com
Electrical life expectancy
C-platform curves 2
AC Current breaking capacity versus life expectancy in millions of cycles. DC Current breaking capacity versus life expectancy in millions of cycles.
Rate of contacts opening and closing = 1200 operations per hour. Rate of contacts opening and closing = 1200 operations per hour.
VK400 curve
Curves shown for resistive (PowerNo.1
factor = 1) Curves shown for inductive load -
L/R = 20 ms continuous current
Curves 1 2 3 4 L/R = 40 ms continuous current
VAC 220 125 48 24
Curves 1-3 2-4 5-7 6-8
Curves 1-3 2-4 5-7 6-8
60 VDC 220 125 48 24
50 Vcc 220 125 48 24
4
40
30
20 60
3
50
40
10
30
2 25
Millions of Cycles
5 20
1
15
2,5
Millions of Cycles
10 6 8
4 5
9
8
3
7
2 7
1 6
1
5
4
0,5
3
2
0,2
1,5
0,1 1
0 0
0,75 1 1,5 2 2,5 3 3,5 4 5 6 7,5 9 0,15 0,2 0,4 1 2 3 4 5 6 7 8 9
Amps Amps
280
270
260
60
250
50
4 240
40
230
30 220
3 210
25
200
20
190
2 180
15
Millions of Cycles
170
1
160
10
9 150
Volts
1
8 140
7
130
6 2
120
5 3
110
4
100 4
3 90
80
70
2 5
60
1,5 50
40
30
1
6
20
0
0,15 0,2 0,4 1 2 3 4 5 6 7 8 9 10
0
Amps 0,75 1,5 2,25 3 3,75 4,5 5,25 6 6,75 7,5 8,25 9 9,75
151
www.morssmitt.com
Electrical life expectancy
C-platform curves 2
ACcurrent
AC Current breaking
breaking capacity
capacity versus
versus life life expectancy
expectancy in millions
in millions of cycles.
of cycles.
Rateofofcontacts
Rate contacts opening
opening andand closing
closing = 1200
= 1200 operations
operations per hour.
per hour.
Values
Values shown
shown forfor inductive
inductive loads:
loads:
Cos Ø = 0.7
Cos Ø = 0.7
Cos Ø = 0.5
Cos Ø = 0.5 Curves 1,3 & 5Curves
2 , 4 &1,36&4 6,2,5
9 &&710 6,98,
&1011 &8,11
12 &12
Cos Ø = 0.3
Cos Ø = 0.3 VAC 220 VAC 125 220 125
48 48 24 24
60
50 60
12
40 50 12
40
30
30 11
20 11
10
20
10
9
10 9
10 8
8
7
5 7
6
Millions of Cycles
5
5 6
Millions of Cycles
4 5
2,5
4
2,5
3
3
1
2
1
2
0,5
0,5 1
1
0,2
0,2
0,1
0 0,1
0,75 1 2 2,5 2,5 3 3,5 4 4,5 5 6 7,5 9
0
1 1,5 2 2,5 3
Amps 4 5 6 7 8 10 12
Amps
152
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Suitable for
• C
• CG
• CK
• CM
• SB
• SC
• UTC
153
www.morssmitt.com
154
www.morssmitt.com
Specials
155
www.morssmitt.com
Specials
Design features
Instantaneous / latching with 19/18 N/O or N/C contacts ....with 40 N/O or N/C contacts
RC19
D4-module D8-module
156
www.morssmitt.com
Instantaneous
Contact data
Maximum continuous current 8A
Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
Options
1 operation per minute
• Gold contacts Minimum contact continuity 20 mA at 24 VDC
• Gold bifurcated and silver contacts Number of contacts 19 double break contacts (form X and Y)
Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 8 A
Contact resistance - end of life 40 mΩ max at 8 A
Timing diagram Electrical life expectancy See curves on page 175
a1
a2
b1 a1
a2
b1 a1
a2
220 176 / 242a1
b1
a2
4 129
b1 21 12000
b2 b2 b2 b2
a3 b3 a3 b3 a3 b3 a3 b3
a4 b4 a4 b4
(1) Minimum assured value
a4 b4 a4
(3) Coil resistanceb4tolerance: ± 8 % at 20 °C
c0 d0 c0 d0 (2) Maximum assured d0
c0 value c0 (4) Valid for closedd0relay
d1 d1 d1
c1 c1
Other types on requestd1
c1 c1
c2 d2 c2 d2 c2 d2 c2 d2
c3 d3 c3 d3 c3 d3 c3 d3
c4 d4 c4 d4 c4 d4 c4 d4
e0 f0 e0 f0 e0 f0 e0 f0
e1 f1 e1 f1 e1 f1 e1 f1
e2 f2 e2 f2 e2 f2 e2 f2
e3 f3 e3 f3 e3 f3 e3 f3
e4 f4 e4 f4 e4 f4 e4 f4
g0 h0 g0 h0 g0 h0 g0 h0
g1 h1 g1 h1 g1 h1 g1 h1
g2 h2 g2 h2 g2 h2 g2 h2
g3 h3 g3 h3 g3 h3 g3 h3
g4 h4 g4 h4 g4 h4 g4 h4
157
www.morssmitt.com
Latching
• Plug-in design
• Latching relay with 2 separate coils and magnetic rocker mechanism
• 18 double break contact in all N/O and N/C combinations
(form X and Y - per customer specification)
• Weld-no-transfer contacts standard
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Minimum contact continuity 20 mA at 24 VDC
Options
Number of contacts 18 double break contacts (form X and Y)
• Gold contacts Contact material Hard silver overlay laminated to copper (gold
• Gold bifurcated and silver contacts contacts optional )
• Transil coil protection Contact resistance - initial 10 mΩ max at 8 A
• Built-in lever to actuate relay manually
Contact resistance - end of life 40 mΩ max at 8 A
Electrical life expectancy See curves on page 175
Timing diagram
Mechanical & environmental characteristics
Mechanical life > 100 x 106 operations
Weight 639 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) R coil (Ω) (1) L/R (ms) (2)
36 25 / 45 5.2 250 25
72 48 / 90 5.2 1000 25
110 77 / 138 5.2 2400 25
Connection diagram (example) (1) Coil resistance tolerance: ± 8 % at 20 °C
(2) Valid for closed relay
this coil controls this coil controls COIL 1
closing of NC + a0 Other
closing of NCtypes on request
+ a0
contacts and COIL 1 contacts and
opening of NO - b0 opening of NO - b0
contacts. contacts.
g0 h0 a1 b1
a1 b1 a2 b2
a2 b2 a3 b3
a3 b3 a4 b4
c0 d0 c0 d0
c1 d1 c1 d1
c2 d2 c2 d2
c3 d3 c3 d3
c4 d4 c4 d4
e0 f0 e0 f0
e1 f1 e1 f1
e2 f2 e2 f2
e3 f3 e3 f3
e4 f4 e4 f4
g1 h1 g0 h0
g2 h2 g1 h1
g3 h3 g2 h2
- b4 a4 g3 h3
this coil controls this coil controls
closing of NO + g4 + g4
closing of NO
contacts and
opening of NC - h4
COIL 2
Dimensions
contacts and
- h4
opening of NC
See page 167
COIL 2
contacts.
Mounting possibilities
contacts.
& sockets
(shown with optional Transil protection)
See page 174
Contact arrangement
9 NC and 9 NO
Detailed information and datasheets available on www.morssmitt.com
Contact arrangement
4 NC and 14 NO
SCHEMATIC #1 SCHEMATIC #2
158
www.morssmitt.com
Instantaneous
• Plug-in design
• Instantaneous, safety-critical relay
• 40 double break contact in all N/O and N/C combinations
• Weld-no-transfer contacts standard
• Contact life (mechanical) of 100 million cycles
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Options Contact overload withstand At 24 VDC: 10 x 160 A at L/R = 0 for 10 ms,
• Transil coil protection 1 operation per minute
Minimum contact continuity 20 mA at 24 VDC
Number of contacts 40 double break contacts (form X and Y)
Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 8 A
Contact resistance - end of life 40 mΩ max at 8 A
Timing diagram Electrical life expectancy See curves on page 175
Mechanical & environmental characteristics
Mechanical life > 100 x 106 operations
Weight 1800 g
Operating temperature -40 °C...+80 °C
Humidity 93 % RH, 40 oC for 4 days
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) Uhold (1)(VDC) Udrop-out (2)(VDC) Rcoil (3)(Ω) L/R (4)(ms)
36 25 / 45 6 21 3.5 215 10
72 48 / 90 6.5 40.5 6.5 800 10
Connection diagram (examples)
(1) Minimum assured value (3) Coil resistance tolerance: ± 8 % at 20 °C
(2) Maximum assured value (4) Valid for closed relay
Other types on request
A0 A0 A0
A1 A1 A1
B0 to B4 C0 to C4 B0 to B4 C0 to C4 B0 to B4 C0 to C4
D0 to D4 E0 to E4 D0 to D4 E0 to E4 D0 to D4 E0 to E4
F0 to F4 G0 to G4 F0 to F4 G0 to G4 F0 to F4 G0 to G4
H0 to H4 J0 to J4 H0 to H4 J0 to J4 H0 to H4 J0 to J4
K0 to K4 I0 to I4 K0 to K4 I0 to I4 K0 to K4 I0 to I4
M0 to M4 N0 to N4 M0 to M4 N0 to N4 M0 to M4 N0 to N4
P0 to P4 Q0 to Q4 P0 to P4 Q0 to Q4 P0 to P4 Q0 to Q4
R0 to R4 S0 to S4 R0 to R4 S0 to S4 R0 to R4 S0 to S4
159
www.morssmitt.com
Latching
• Plug-in design
• Latching relay using 2 separate coils and magnetic rocker mechanism
• 40 double break contact in all N/O and N/C combinations
• Weld-no-transfer contacts standard
• Contact life (mechanical) of 100 million cycles
• Positive mechanical keying of relay to socket is done during manufacaturing
• Secure locking feature for maximum ease of maintenance
Contact data
Maximum continuous current 8A
Options
Minimum contact continuity 20 mA at 24 VDC
• Transil coil protection Number of contacts 40 double break contacts (form X and Y)
• Without manual command Contact material Hard silver overlay laminated to copper
Contact resistance - initial 10 mΩ max at 8 A
Electrical life expectancy See curves on page 175
Nominal voltage
Unom (VDC) Uoperating (VDC) Pnom (W) Rcoil (1)(Ω) L/Rcoil 1(2)(ms) L/Rcoil 2(2)(ms)
24 16 / 33 2.6 220 70 50
72 48 / 90 2.6 2000 70 50
110 75 / 138 3 4600 70 50
(1) Coil resistance tolerance: ± 8 % at 20 °C
(2) Valid for closed relays
Connection diagram Other types on request
A0
Coil 1
A1
B0 to B4 C0 to C4
D0 to D4 E0 to E4
F0 to F4 G0 to G4
H0 to H4 J0 to J4
K0 to K4 I0 to I4
M0 to M4 N0 to N4
P0 to P4 Q0 to Q4
R0 to R4 S0 to S4
A3
Coil 2
A4 Dimensions See page 167
Mounting possibilities & sockets See page 174
Contact arrangement Detailed information and datasheets available on www.morssmitt.com
15 NC and 25 NO
160
www.morssmitt.com
Monitoring
Contact data
Amount and type of contacts 2 C/O
Maximum make current 15 A
Options Maximum continuous current 6A
On request Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
Minimum switching voltage 12 V
Minimum switching current 10 mA
Contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Maximum switching capacity and See curves on page 130
electrical life expectancy
Nominal voltage
setpoint Type Inom (AAC) Frequency (AAC) Imax (AAC)
CMP 0.2 - 0.6 0.2 - 0.6 16 - 60 0.6
t
Out
CMP 0.5 - 1.5 0.5 - 1.5 16 - 60 1.5
CMP 1-3 1-3 16 - 60 3
CMP 2-6 2-6 16 - 60 6
t
CMP 4-12 4 - 12 16 - 60 12
Other types on request
Connection diagram
161
www.morssmitt.com
Monitoring + timer
162
www.morssmitt.com
Monitoring + timer
www.morssmitt.com
Monitoring
• Compact design
• AC current monitoring relay, 1 C/O contact
• High continuous overcurrent possible
• Protection against short circuit and low impedance
• Also suitable for earth fault protection
• Easy installation
Contact data
Maximum make current 15 A
Maximum continuous current 6A
Options Maximum switching voltage 300 VDC (then max. current = 300 mA)
250 VAC (then max. current = 2.6 A)
On request
Minimum switching voltage 12 V
Minimum switching current 10 mA
Maximum contact resistance 15 mΩ
Material Ag + 0.2 µm Au (gold flash is only for storage purpose)
Electrical life expectancy and See curves on page 175
maximum switching capacity
Nominal voltage
I pull-in Type Unom (VDC) Umin (VDC) Umax (VDC)
I drop-out RC-19A 4.8 4.8 3.1 - 3.8 1.9 - 3.4
RC-19A 14 14 9.0 - 11.0 3.5 - 5.0
RC-19A 35 35 22.5 - 27.5 9.0 - 11.0
Other types on request
Example:
• Type RC-19A 4.8 with the current wire through the relay ring (no windings):
Ipull-in is between 3.1-3.8 A. After activating the relay Idrop-out is between 1.9-3.4 A
Connection diagram
• Type RC-19A 4.8 with the current wire winded 3 times around the relay ring
(3 windings, wire goes through relay ring 4 times):
Ipull-in is between 1.0-1.3 A. After activating the relay Idrop-out is between 0.6-1.1 A
164
www.morssmitt.com
Instantaneous
Contact data
Options
Maximum make current 16 A
• Low temperature (-50 OC) Maximum continuous current 10 A for 30 min
• Gold plated contacts
Maximum switching voltage 250 VDC, 440 VAC
• Special dust protection
• AgSnO2 contacts Minimum switching voltage 12 V
• No magnetic arc blow-out Minimum switching current 10 mA
• Double zener diode Maximum breaking capacity 110 VDC, 8 A (L/R ≤ 15 ms)
230 VAC, 10 A (cos ϕ ≥ 0.7)
Contact resistance 15 mΩ (initial)
Material Ag standard (optional AgSnO2, Au on Ag)
Electrical life expectancy See curves on page ..
165
www.morssmitt.com
Instantaneous & timer
Nominal voltage
Timing diagram Instantaneous & Instantaneous / time delayed versions
Instantaneous Instantaneous / time delayed Type Unom (VDC) Umin (VDC) Umax (VDC)
in
D8-U201-DxxxTxxx 24 16.8 30
D8-U202-DxxxTxxx 48 33.6 60
out-I
D8-U203-DxxxTxxx 72 50.4 90
D8-U204-DxxxTxxx 110 77.0 138
D8-U205-DxxxTxxx 96 67.2 120
out-T
D8-U207-DxxxTxxx 36 25.2 45
Other types on request
ton
D8-U200-044
D8-U200-D022T011
Dimensions See page 170
166
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• 303
• Relay
310shown with Socket assembly no. 153913 TYPE COR NK 58D (or160 967 TYPE COR SA).
Included is socket with locking bracket and locking spring.
Locking Spring
removal : 15 mm ( . 590” )
C l earance f or rel ay
111mm
S ock et
93mm (4.370")
Relay
(3.661") 119mm
(4.690")
Relay shown with Socket assembly no. 907983 TYPE COR PA 58D.
Included is socket with guide plate, locking bracket and locking spring. The guide plate aligns the relay
with the socket for easy plugging in when the socket is not readily accessible.
Locking Spring
Locking Bracket
7mm (.276")
Dimensions (mm)
for relay type:
removal : 15 mm ( . 590” )
BOTTOM
C l earance f or rel ay
• 401
TOP
S ock et
111mm
• 40793mm Relay
(4.370")
(3.661") 119mm
(4.690")
Guide
(Reference # 907 894)
52mm
Mounting hole layout (2.047") Important note: Each relay and socket is
uniquely keyed to prevent accidental
insertion of the wrong relay into a socket.
77mm This safety feature assures that only
(3.031") the relay specified for the circuit will be
accepted by the socket. The keying
93mm
system employs 2, 3 or 4 pins positioned
(3.661")
4 x Ø5.2 correspondingly in the relay base and
5.2mm Dia - 4 holes the socket to assure that only the correct
(.204") relay and socket will mate.
56mm
(2.204")
167
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• CMP
Dimensions (mm)
for relay type:
• NSE
• NSR
168
www.morssmitt.com
Dimensions
Dimensions (mm)
for relay type:
• RC-19A
169
www.morssmitt.com
Dimensions
Dimensions (mm)
for type:
• D4-U200
module 71,4
45
101,5
Spring connection
Dimensions (mm)
for type: 45 27.2
25 14.4
• D8-U200
module
45
97 35
57.5
110
93
1.5
93
50
10
1.5
1.5
1.5
93
50
93
10
4.2
5
1.5
170 1.5
www.morssmitt.com
93
Electrical life expectancy
Specials curves 1
Current breaking capacity versus life expectancy in millions of cycles.
Rate of contacts opening and closing = 1200 operations per hour.
Duty cycle = 50%.
Unless otherwise indicated, values are for resistive circuits where L/R=0 and Cos Ø = 1.
* indicates inductive circuit with L/R = 10 ms.
** indicates inductive circuit with Cos Ø = 0.4
Curve 1 2 3 4 5 6 7
Voltage 220VDC 120VDC 48VDC 24VDC 12VDC 6VDC 48VDC*
220VAC 120VAC 48VAC 24VAC 220VAC**
15
14
13
12
11
10
6
9
8
7
6
5
5
Millions of Cycles
4
4
1
1 2 7 3
0,5
0,1
0 0, 25 0, 5 1 1, 5 2 2, 5 3
Amps
Specials curves 2
Maximum switching capacity Electrical life expectancy
1000 100
AC
% of maximum switching capacity
DC resistive
Power (W)
100 10
DC inductive
DC
AC resistive
AC inductive
10 1
10 100 1000 0,10 1,00 10,00 100,00
Step 2 Select the maximum switching capacity (in Watt) at this voltage in graph
‘Maximum switching capacity’.
Step 3 Calculate the actual switched load (in Watt) out of the application.
Step 5 Pick the life at this load out of the graph ‘Electrical life expectancy’.
171
www.morssmitt.com
Electrical life expectancy
Specials curves 3
2, rue de la mandinière
INSTANTANEOUS RELAY STDA5019 Ed4
2, rue de la mandinière
INSTANTANEOUS RELAY STDA5019 Ed4
72300 SABLE SUR SARTHE
72300 SABLE SUR SARTHE Tél. : (33) 2 43 92 82 00
MODEL V 400 Model
Tél. : (33) 2 43 92 82 00
MODEL V 400 Model Fax : (33) 2 43 92 82 18
2, rue de la mandinière INSTANTANEOUS RELAY
72300 SABLE SUR SARTHE
Christophe GUILLEVIN
Tél. : (33) 2 43 92 82 00 MODEL
9 /V
9 400 Model
STDA5019 Ed4
27/11/2007
2, rue de la mandinière
Christophe GUILLEVIN
72300 SABLE SUR SARTHE INSTANTANEOUS
8/9 RELAY STDA5019 Ed4
27/11/2007
Fax : (33) 2 43 92 82 18 Tél. : (33) 2 43 92 82 00
MODEL V 400 Model
Dynamic relay selection curve No 3
DYNAMIC RELAY SELECTION CURVES Dynamic relay selection curve No 4
Fax : (33) 2 43 92 82 18
172
www.morssmitt.com
Electrical life expectancy
Specials curves 3
2, rue de la mandinière INSTANTANEOUS RELAY
72300 SABLE SUR SARTHE
Tél. : (33) 2 43 92 82 00 MODEL V 400 Model STDA5019 Ed4
Fax : (33) 2 43 92 82 18
60
50 60 12
40 50 12
30 40
11
30
20
10 11
20
9 10
10 9
8
10
7 8
5
6
Millions of Cycles
7
5 5
6
Millions of Cycles
4
2,5 5
4
2,5
3
1 3
2
1
2
0,5
1
0,5
1
0,2
0,2
0,1
0
1 1,5 2 2,5 3 4 5 6 7 8 10 12
0,1
0
Amps
1 1,5 2 2,5 3 4 5 6 7 8 10 12
Amps
173
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Suitable for
• 303
• 310
COR NK COR PA
COR SA
Suitable for
• 401
• 407
COR OU
174
www.morssmitt.com
Electronic timer modules
175
www.morssmitt.com
Electronic timer module
TB AO Delay on pull-in
Delay on pull-in timing module offering a short range duration
(0.25 s to 40 s) and controls an external load from a common source.
Electrical characteristics
Operating voltage 24 VDC...110 VDC
Operating current < 20 mA
Maximum load current 0.8 A
Connection diagram
(Built-in connections)
c1 b1
Connections to be made
a1 b2
Connections to be made
TB AO
a2 b3
(delay ON)
a3 c4
176
www.morssmitt.com
Electronic timer module
TB OR Delay on drop-out
Delay on drop-out timing module offering a short range duration
(0.25 s to 40 s) and controls an external load from a common source.
Connection diagram
(Built-in connections)
a1 b2
Connections to be made
TB OR
a2 b3
a3
(delay OFF)
c4
Dimensions See page 185
Mounting possibilities & sockets See page 186
b4 c3
Detailed information and datasheets available on www.morssmitt.com
a4 c2
177
www.morssmitt.com
Electronic timer module
Connection diagram
(Built-in connections)
c1 b1
Connections to be made
a1 b2
Connections to be made
TAL AO
a2 b3
(delay ON)
a3 c4
178
www.morssmitt.com
Electronic timer module
Connection diagram
(Built-in connections)
a1 b2
Connections to be made
TAL OR
a2 b3
(delay OFF)
a3 c4
Dimensions See page 185
b4 c3
Mounting possibilities & sockets See page 186
a4 c2 Detailed information and datasheets available on www.morssmitt.com
179
www.morssmitt.com
Electronic timer module
Connection diagram
(Built-in connections)
c1 b1
Connections to be made
a1 b2
Connections to be made
TBL AO
a2 b3
(delay ON)
a3 c4
b4 c3
Dimensions See page 185
a4 c2
Mounting possibilities & sockets See page 186
Detailed information and datasheets available on www.morssmitt.com
180
www.morssmitt.com
Electronic timer module
Connection diagram
(Built-in connections)
a1 b2
Connections to be made
TBL OR
a2 b3
(delay OFF)
a3 c4
Dimensions See page 185
b4 c3 Mounting possibilities & sockets See page 186
Detailed information and datasheets available on www.morssmitt.com
a4 c2
181
www.morssmitt.com
Electronic timer module
Closed
Open
On
Off
Connection diagram
Time delay
Permanent load
Power supply d1 d3
TA3 d2
Load
Switch
182
www.morssmitt.com
Electronic timer module
Connection diagram
(Built-in connections)
c1 b1
Connections to be made
a1 b2
Connections to be made
TCAL
a2 b3
a3 c4
b4 c3
183
www.morssmitt.com
Electronic timer module
Connection diagram
Direct Load
Feed Acceptable
Load
(wiper engine relay)
d3
Timer
d2
c4
Sequence Setting
Potentiometer
(0 - 47K ohms) Dimensions See page 185
47K Mounting possibilities & sockets See page 186
d1 Power Supply d4
Detailed information and datasheets available on www.morssmitt.com
184
www.morssmitt.com
Dimensions
• TB AO
• TBOR
• TBL AO
• TBL OR
Used Used
with locking
locking brackets
brackets with wire
wire locking
locking spring
spring
• TALAO
• TALOR
• TA3
• TCAL
• TAC
Used Used
with locking brackets with wire locking spring
185
www.morssmitt.com
Sockets
• Proven reliable
• Long term availability
• No maintenance
• Low life cycle cost
Suitable for
• TALAO
• TALOR
• TA3
EA 104 A EA 112 AF • TCAL
• TAC
Suitable for
• TB AO
• TB OR
• TBL AO
EA 104 B EA 112 BF • TBL OR
186
www.morssmitt.com
Relays - alphabetical
187
www.morssmitt.com
Mors Smitt Railway Technology
Railway relays
SALES OFFICES
FRANCE
Mors Smitt France SAS
Tour Rosny 2, Avenue du Général de Gaulle,
F - 93118 Rosny-sous-Bois Cedex, France
T +33 (0) 1 4812 1440
F +33 (0) 1 4855 9001
E [email protected]
HONG KONG
Mors Smitt Asia Ltd.
29/F., Fun Tower, 35 Hung To Road
Kwun Tong, Kowloon, Hong Kong SAR
T +852 2343 5555
F +852 2343 6555
E [email protected]
THE NETHERLANDS
Mors Smitt B.V.
Vrieslantlaan 6
3526 AA Utrecht, The Netherlands
T +31 (0)30 288 1311
F +31 (0)30 289 8816
E [email protected]
UNITED KINGDOM
Mors Smitt UK Ltd.
Graycar Business Park, Barton under Needwood,
Burton on Trent, Staffordshire, DE13 8 EN, UK
T +44 (0)1283 722 650
F +44 (0)1283 722 651
E [email protected]
USA
Mors Smitt Technologies Inc.
1010 Johnson Drive
Buffalo Grove, IL 60089-6918, USA
T +1 847 777 6497
F +1 847 520 2222
E [email protected]
www.morssmitt.com