Evaluation Statement For Zero PD
Evaluation Statement For Zero PD
1 Objective 1. Treatment of Batching Plant Machinery wash water containing thin concrete
slurry with cemented coarse and fine aggregates
2. Recovery of coarse and fine aggregates for reuse in lean mix preparation
2 Capacity 20 cum/hr
No Description Raw Effluent PCB Discharge Treated Water
3 Raw Effluent Parameter Norms Parameters
Parameters 1 pH <8 6.5 to 9 7-7.5
(Tentative) 2 Specific 1150 Kg/ cum NA
Gravity
3 TSS <1500 ppm <30 ppm 5 – 10 ppm
4 Oil and <20 ppm < 10 ppm < 10 ppm
Grease
4 Technical 1. Slurry water collected in a wahing 1. Slurry Water collected in a
Proposal pit (Collection Tank) Collection cum Attenuation
Tank for collection of effluent
2. Pumped to Recyling Tank with 2 and attenuation of oversized
KW agitator automated with timer gravels
control
2. Pumoed to Hydrocyclone for
3. Pumped to Concrete Reclaimer centrifugal separation of coarser
(Settling Tank) with 5.5 KW particles in the slurry
Drive
3. Coarse Aggregates from bottom
4. Coarse Aggregates settled in of hydrocyclone drained out by
Concrete Reclaimer recovered and gravty
supernatant pumped to Filter Press
S.No Description SN Engineering Services Proposed Remarks
4. Supernatant of hydrocyclone
5. Fine aggregates recovered as cakes passed to Automated Self
and filtrate recovered as treated Cleaning hydraulic Screen
water here in Filter Press Filters for polishing the treated
water and recovery of slurry
particles