DATASHEET
#57006 rev 2.1
Basic Specifications
Maximum continuous operating
temperature is 930 °C
Maximum temperature for short period is
1030 °C (maximum 10 minutes)
Mounting torque 60 Nm max
Lifetime estimates:
The Bosch LSU 4.9 sensor is a 5 wire
Sensor lifetimes are highly dependent on
wideband Lambda sensor. It is used to
application. Typically sensor lifetime for
control fuel and ignition systems to optimize
high performance engines is 500 hours in
a car's performance in the areas of emissions
unleaded fuel and 50 hours in leaded fuel.
See also Sensor lifetime page 4
and fuel economy.
Fuel: Unleaded gasoline, ethanol gasoline The Lambda sensor can be connected directly
blends, methanol, diesel, LNG, CNG, LPG to any MoTeC ‘hundred series’ ECU with a
Lambda upgrade enabled. It can also be
Other Information connected via the PLM to any ECU or Dash
Compatibility Logger.
‘hundred series’ ECUs: M400, M600, M800, Lambda gives a measure of the Air to Fuel
M880 Ratio (AFR) that is independent of the type of
PLM - Professional Lambda meter fuel being used.
LTC/LTCD – Lambda to CAN modules Stoichiometric ratio: no
Lambda 1.00 excess fuel and no
Accessories excess air
#59001 Mild steel weld-in bung M18x1.5 Lambda > 1.00 Lean: excess air
#59002 Stainless steel weld-in bung Lambda < 1.00 Rich: excess fuel
M18x1.5
For a quick reference table to convert Lambda
#64010 Mating connector to AFR for various fuels see page 3.
#61118 Adapter loom (sensor connector to MoTeC ECUs allow for a Lambda aim table
DTM connector) based on load and RPM. Referencing the
Complete Kit measured Lambda, the Quick Lambda
The complete Lambda kit contains a PLM, function in the software adjusts the values in
Bosch LSU 4.9 Lambda sensor, and all the fuel control table at the specified load and
required looms and accessories: RPM site to achieve the aim Lambda.
#15005 kit with short loom - length 2.6 m Similarly, the Lambda Was function adjusts
the values in the fuel control table using
#15005LL kit with long loom - length 6.0 m
recorded Lambda measurements from a data
log.
MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, [email protected]
Product specifications are subject to change
PRODUCT
DATASHEET
#57006 rev 2.1
M400/M600/ M880
Pin Name Name Pin Name Pin Name
M800 Pin Pin
MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, [email protected]
PRODUCT
DATASHEET
#57006 rev 2.1
nd
l
Lambda
no
e
1. On the Adjust menu, click Sensor Setup
lin
ble
a
el
and then Input Setup.
th
so
es
G
5
Me
Ga
E8
LP
Double-click the Lambda 1 (La1)
Di
channel and in the Input Source box, 0.70 10.3 4.5 6.8 10.2 10.9
select Lambda 1. 0.75 11.0 4.8 7.3 10.9 11.6
Click Predefined, select #38 0.80 11.8 5.1 7.8 11.6 12.4
Lambda Internal LSU or NTK and 0.85 12.5 5.4 8.3 12.3 13.2
click OK twice.
0.90 13.2 5.8 8.8 13.1 14.0
2. On the Adjust menu, click Sensor Setup 0.95 14.0 6.1 9.3 13.8 14.7
and then Wideband Lambda Setup.
1.00 14.7 6.4 9.8 14.5 15.5
Click Sensor Type and enter 7 (LSU
1.05 15.4 6.7 10.3 15.2 16.3
4.9 Normal) or optional 8 (LSU 4.9
Fast Heat). 1.10 16.2 7.0 10.8 16.0 17.1
Click ESC, then click Calibration 1.15 16.9 7.4 11.2 16.7 17.8
Number and enter the number as 1.20 17.6 7.7 11.7 17.4 18.6
explained on screen. 1.25 18.4 8.0 12.2 18.1 19.4
Click ESC, then click Quick Lambda 1.30 19.1 8.3 12.7 18.9 20.2
MODE and enter the number as 1.35 19.8 8.6 13.2 19.6 20.9
explained on screen. 1.40 20.6 9.0 13.7 20.3 21.7
3. On the Adjust menu, click Auxiliary 1.45 21.3 9.3 14.2 21.0 22.5
Output Functions 1.50 22.1 9.6 14.7 21.8 23.3
Click Auxiliary Out #X - choose the
1.55 22.8 9.9 15.1 22.5 24.0
number of the output that has the
1.60 23.5 10.2 15.6 23.2 24.8
sensor heater connected.
Enter 9 (Lambda Sensor Heater) and
click ESC.
Click Parameters and enter 1 for
Lambda 1.
Repeat the configuration for a second Lambda
sensor if required (not available in M400).
MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia
www.motec.com, Ph 61 3 9761 5050, Fax 61 3 9761 5051, [email protected]
PRODUCT
DATASHEET
#57006 rev 2.1
Sensor Lifetime
Sensor lifetimes are highly dependent on
application for example the type of fuel used
Correct and the volume of gas flow over the sensor.
Incorrect
Some factors that reduce sensor lifetime are:
Place the sensor at least 1 meter from the
Contaminants such as silicon, lead, oil, etc.
exhaust ports to avoid excessive heat
(use sensor-friendly sealants)
(recommended).
Thermal cycling and exposure to exhaust
Place the sensor at least 1 meter from the
fumes without any heating control active
open end of the exhaust system to avoid
incorrect readings due to outside oxygen Incorrect placement in the exhaust that can
(recommended). overheat the sensor
Place the sensor away from the flame front Leaded fuel – substantially reduces lifetime
coming out of the cylinder head and away Water jacketed exhaust manifolds as in
from areas where one cylinder may have PWCs – substantially reduces lifetime
more effect than another. At the end of its life the sensor becomes slow
If possible, do not place the sensor near to respond and does not read rich properly.
exhaust slip joints; some designs allow air Regular free air calibrations will maintain the
to enter resulting in incorrect readings. accuracy of the sensor over its lifetime.
MoTeC Pty. Ltd, 121 Merrindale Drive, Croydon South, Victoria 3136, Australia