TMI Data 300311
TMI Data 300311
4 gen-sets
GenSet Rating kWe Rating kWe Leroy
Model @ 60 Hz PRIME @ 50 Hz PRIME Model
C4.4 TAG2 98.6 85.8 LSAM 44.2 S7
C4.4 TAG1 78.6 68.7 LSAM 44.2 VS3
C4.4 T 57.9 50.9 LSAM 43.2 L65
C4.4 NA 43.7 37.7 LSAM 43.2 S25
4.4 gen-sets
Phase
3
3
3
3
C4.4 GenSet Test Data
Engine Speed rpm 1800 1800 1500 1500 1800 1800 1500 1500
Engine Power kW 53.4 48.9 47 42.7 70 63.6 62 56.4
Engine Power @ 50 Deg C kW 50.8 46.2 44.2 40.1 65.6 59.8 58.3 53
Engine Torque Nm 286 260 299 272 372 337 391 363
BMEP Bar 8.18 7.43 8.6 7.77 10.63 9.62 11.18 10.37
Published Electrical Power H/Exch Cooled ekW 48.0 44.0 41.5 38.0 63.5 58.0 56.0 51.0
Electrical Power H/Exch Cooled
50Deg Ambient ekW 44.5 41.5 38.5 35.5 59.0 55.0 52.0 48.5
Radiator Powers (less 2eKw for NA & T
Less 4eKw for DITA ekW 46.0 42.0 39.5 36.0 61.5 56.0 54.0 49.0
Radiator Power @ 50 Deg Ambient ekW 42.5 39.5 36.5 33.5 57.0 53.0 50.0 46.5
Eng/Oil Sump oC 113 113 107 106 113 111 106 106
Eng Oil Gallery oC 102 102 105 105 101 101
Eng/Oil Press Bar 3.7 3.7 3.7 3.7 3.46 3.48 3.39 3.38
Cylinder Heat Temp oC 85.4 84.7 82.6 82.6 83.6 83.6 84.3 83.6
Heat Ex Inlet oC 74.38 74.14 72.06 71.83 85.81 85.62 85.16 84.66
Heat Ex Outlet oC 48.07 45.79 42.01 40.68 64.79 63.32 64.47 62
Ex Man FWater In oC 73.99 73.98 71.51 71.49 85.13 85.19 84.19 83.84
Ex Man FWater Out oC 76.23 75.85 73.25 72.91 88.4 87.98 87.48 86.77
Water Pump Inlet oC 75.6 73.3 72.1 73.5 74.9 74.9 73.5 73.5
Baro Press mBar 1008 1008 1018 1018 1001 1001 1001 1001
Comp Delivery Press Bar
Boost Press/Inlet Man Bar 0.98 0.91 0.96 0.89
Exh Track Press Bar 0.89 0.86 86 0.81
Exh Back Press kPa 15 15 15 15 15 15 15 15
C4.4 GenSet Test Data
Fuel Cons g/sec 3.453 3.095 2.913 2.627 4.534 4.03 3.77 3.536
Fuel Cons litres/hr 14.5 13.0 12.2 11.0 19.0 16.9 15.8 14.8
Fuel Delivery mm3/s 67.4 60 68 61.2 87.8 78.1 87.9 82.2
SFC g/kWh 233 228 222 221 233 228 222 224
Cylinder bore mm 105 105 105 105 105 105 105 105
Stroke mm 127 127 127 127 127 127 127 127
Displacement litres 4.40 4.40 4.40 4.40 4.40 4.40 4.40 4.40
Compression ratio 19.3 19.3 19.3 19.3 18.2 18.2 18.2 18.2
Induction System Naturally Aspirated Turbocharged
C4.4 GenSet Test Data
COOLING SYSTEM
Min Sea Cock Dia 25.4mm 38.1mm 25.4mm 38.1mm
Max Lift of Sea Water Pump 2m 4m 2m 4m
Pressure Cap Setting 50 kPa 50 kPa
Max Engine Room Temp 60 oC 60 oC
Max Sea Water Inlet Temp 38 oC 38 oC
COOLANT
Recommended coolant inhibitor CAT Extended Life Coolant. 50/50 mix CAT Extended Life Coolant. 50/50 mix
Total Coolant Capacity 16.5 L 16.5 L
Maximum external system resistnce 35 kPa 35 kPa
THERMOSTAT
Operating Range 82 - 94 oC 82 - 94 oC
EXHAUST SYSTEM
Max Back Pressure for Total System 15 kPa 15 kPa
Recommended Exhaust Pipe Bore (Dry) 57.0mm 57.0mm
Recommended Exhaust Pipe Bore (Wet) 76.2mm 76.2mm
INDUCTION SYSTEM
Max Permissible Air Intake Restriction Clean 5kPa Clean 5kPa
Dirty 8kPa Dirty 8kPa
Air Filter Type 2 Stage cyclonic/paper element 2 Stage cyclonic/paper element
LUBRICATION SYSTEM
Lubrication Oil Specification API-CG4/CH4 or ACEA-E3/E5 API-CG4/CH4 or ACEA-E3/E5
Total Lub Oil Capacity 8.5 L 8.5 L
Sump Oil Capacity 7.5 L 7.5 L
Normal Operating Angles 25 deg horizontal in any direction 25 deg horizontal in any direction
Lub Oil Consumption @ full load as a % fuel consumed 0.15% as a % fuel consumed 0.15%
34 36 36 36
106 88 88 88
123 90 90 90
117 96 96 96
4 2 2 2
38 22 24 24
CAT Extended Life Coolant. 50/50 mix CAT Extended Life Coolant. 50/50 mix
16.5 L 16.5 L
35 kPa 35 kPa
82 - 94 oC 82 - 94 oC
15 kPa 15 kPa
76.3mm 76.3mm
102mm 102mm
0.9
0.8
0.7
External Resistance (bar)
0.6
0.5
0.4
0.3
0.2
0.1
0
0 20 40 60 80 100 120 140
External Flow (l/min)
1.4
1.2
1
bar)
1.4
1.2
1
External Resistance (bar)
0.8
0.6
0.4
0.2
0
0 20 40 60 80 100 120 140 160 180
External Flow (l/min)
KC Aftercooler Circuit, 1500rpm
1.6
1.4
1.2
External R eisitance (bar)
0.8
0.6
0.4
0.2
0
120 140 0 10 20 30 40 50 60 70 80 90
External Flow (l/min)
1.8
1.6
1.4
1.2
ar)
1.8
1.6
1.4
1.2
0.8
0.6
0.4
0.2
0
40 160 180 0 20 40 60 80 100
External Flow (l/min)
, 1500rpm
60 70 80 90 100
l/min)
, 1800rpm
80 100 120
l/min)
PROVISIONAL INSTALLATION DATA
C4.4 DINA
100% 110%
ITEM UNITS 50Hz 60HZ 50Hz 60Hz
C4.4 DIT
100% 110%
ITEM UNITS 50Hz 60HZ 50Hz 60Hz
100% 110%
ITEM UNITS 50Hz 60HZ 50Hz 60Hz
100% 110%
ITEM UNITS 50Hz 60HZ 50Hz 60Hz
The air velocity over the radiator is 5 m/s for all the C4.4 radiators.
The volume flow is 1.53 m³/s for the DINA and DIT engines and 2.48 m³/s for the DITA engines.