Automatic Filter Type 6.64 en BOLLFILTER 01
Automatic Filter Type 6.64 en BOLLFILTER 01
TYPE BFD
water,
lubricating oil,
fuel,
machining coolants
The requirements laid down for a modern double filter With 60 variants and the available housing materials
are optimised in the design of the new BFD as a result of (ductile iron, cast steel or stainless steel), the BFD
the versatile concept. In addition, the BFD series combi- series provides a flexible filter solution. The flexibility of
nes the utmost levels of economy with operational safe- the BFD series is enhanced by compliance with the
ty, thanks to: requirements of:
Approximate design in the case of Δpclean = 0,35 bar/5,1 psi with glass fibre elements*
Volume flow Viscosity DN 25 DN 40 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150
lpm/gpm (US) 30 cSt 65/17 190/50 245/65 480/127 715/189 1045/276 1870/494 2710/716
lpm/gpm (US) 40 cSt 60/16 175/46 225/59 430/114 650/172 935/247 1710/452 2450/647
lpm/gpm (US) 50 cSt 55/14 160/42 200/53 395/104 595/157 850/225 1580/417 2270/600
* in the case of star pleated elements with stainless steel mesh, approx. 30 % higher volume flow
THE SOLUTION
Unique construction - perfect function
Process safety by means of filtration is absolutely funda- loss, high dirt-absorbing capacity and high throughput.
mental to filtration technology. On the other hand, the aim The standing or suspended design of the filter elements
is also to achieve optimum economy of the process. For underlines the flexibility of the BFD Double Filter series.
this purpose, in addition to a constant flow cross-section Depending upon the process requirement, disposable
in the housing, which avoids unnecessary pressure losses, elements or filter media, which can be regenerated, are
the new High Flow (HF) generation of filter elements has used.
been developed. This is characterised by low pressure
In practical use, the following features of the BFD Double
Configuration example 1: Filter series are especially convincing
Short housing,
• The compact construction allows for installation in con-
Star pleated element, standing
fined spaces
Filter
inlet • Minimal pressure losses occur, thanks to filtration areas
being optimised for the application and the constant
cross-section from inlet to outlet
• The lower housing cover facilitates maintenance, also
on the clean side of the filter element
• Thanks to its good accessibility, the filter remains fixed
in the pipe when the seal on the ball valve is changed
Filter
outlet
Filter inlet
Filter
inlet
Filter
outlet
T H E D E TA I L S
Trend setting innovations as a standard equipment
Switch-over safety
device locks the switch
lever in the end/final
position and prevents
uncontrolled switching
Not illustrated:
• Heating
Fixing device
Oil pan
BOLL & KIRCH Filterbau GmbH
P. O. Box 14 20 • D- 50143 Kerpen
Siemensstr. 10-14 • D- 50170 Kerpen
Tel.: +49 2273 562-0
2000/09/2016