Vibration Analysis: Diagnosis Report (DR)
Vibration Analysis: Diagnosis Report (DR)
Diagnosis
Element Failures Det ec t ed Co mpo nent spec if ic at io n Po sit io n
COUPLE MISALIGNMENT DRIVE END
BASE STRUCTURAL LOOSENESS DRIVE END
Prognosis
Rec o mmended
Recommended action int ervent io n t ime
THE VIBRATION LEVEL INCREASED AT 1 X MACHINE SPEED FREQUENCY IN AXIAL DIRECTION. IT IS NORMALLY CAUSED 3 Week(s)
ANGULAR MISALIGMENT, THIS SYMPTOMS MAY ALSO INDICATE COUPLING PROBLEMS AS WELL. CHECK THE BASE FOR
DETERIORATED GROUNDING, OR LOOSE HOLD-DOWN BOLTS AT THE BASE. INSPECT COUPLING CONDITION, PERFORM A LASER
ALIGMENT AND GIVE A FEEDBACK TO SEMEQ BEFORE THE NEXT VIBRATION MEASURMENTS ARE TAKEN
Analysed by: THIAGO EDUARDO TEIXEIRA Appro ved by: ALEXANDRE DA COSTA PAES
- - - - -
Def ec t t ype c lassif ic at io n agreed bet ween SEMEQ/COCA-COLA BEVERAGES - PHILIPPINES - ILOILO
Classif ic at io n
analysis agreed
by:
PHILIPPINES - ILOILO S EM EQ