RC602-GE (A) Remote Management 1000M Ethernet Media Converter
RC602-GE (A) Remote Management 1000M Ethernet Media Converter
RC602-GE (A) Remote Management 1000M Ethernet Media Converter
User Manual
Cautions
Please read the following notices carefully before
notice.
the plug.
1
Raisecom Technology Co., Ltd
Content
1. Overview............................................................................................................. 3
1.1. Introduction .............................................................................................. 3
1.2. Features................................................................................................... 3
1.3. Ordering information ................................................................................ 3
2. Parameters ......................................................................................................... 4
2.1. Device specifications................................................................................ 4
2.2. Optical interface specifications................................................................. 4
3. Front view and indicators .................................................................................... 5
3.1. Front view of RC602-GE (A) .................................................................... 5
3.2. Front view 16-slot chassis........................................................................ 6
4. Connection configuration .................................................................................... 7
4.1. Interconnecting Devices........................................................................... 7
4.2. Connect MC with Other Devices (Electrical Port)..................................... 7
4.3. Working Mode Configuration (Electrical Port) .......................................... 7
4.4. Connecting MC with Other Devices (optical port)..................................... 8
5. Installation & preparation .................................................................................... 9
6. Dip-Switch..........................................................................................................11
6.1. Explanation of function configuration DIP-switch ....................................11
6.2. Introduction of type configuration DIP switches...................................... 12
7. Network management....................................................................................... 13
7.1. View the module status .......................................................................... 13
7.2. Configure the module............................................................................. 14
7.3. Reset the module ................................................................................... 14
8. Q&A .................................................................................................................. 15
2
Raisecom Technology Co., Ltd
1. Overview
1.1. Introduction
RC602-GE is 1000M Ethernet media converter that supports both local and remote
management, and the longest transmission distance is 100km. With NView iEMS network
management local RC602-GE can be wholly controlled and configured.
1.2. Features
RC602-GE (A) has Master and Slave working mode. Master is working in central site,
Slave is working in remote site. The working mode can be changed through the
DIP-switch.
Transport Ethernet data at rate of 1000M transparently. Requirement of different
transmission distance and different wavelength can be satisfied.
Flexible network fault management function, which provides optical port RX-to-TX
fault-pass-through, Optical-to-electrical fault-pass-through and Electrical-to-optical
fault-pass-through to satisfy different customers’ needs.
3
Raisecom Technology Co., Ltd
2. Parameters
4
Raisecom Technology Co., Ltd
RMD PWR RX
5
Raisecom Technology Co., Ltd
6
Raisecom Technology Co., Ltd
4. Connection configuration
Please follow the connection rules in the following table when interconnecting RC602-GE
(A) series media converters; otherwise they may not work properly.
Central site Remote site
RC602-GE(A)-M-Master RC602-GE(A)-M-Slave
RC602-GE(A)-S1-Master RC602-GE(A)-S1-Slave
RC602-GE(A)-S2-Master RC602-GE(A)-S2-Slave
RC602-GE(A)-S3-Master RC602-GE(A)-S3-Slave
RC602-GE(A)-SS15-Master RC602-GE(A)-SS13-Slave
RC602-GE (A) series copper to fiber media converters have the function of MID/MIDX
auto-sensing, so they can connect with other devices through straight-though cable or
crossover cable.
Media Other device Connection type of
RJ45 port
converter
Media converter Switch Straight-through,
crossover
Media converter HUB Straight-through,
crossover
Media converter Router Crossover,
straight-through
Media converter NIC Crossover,
straight-through
Electrical port of RC602-GE (A) series copper to fiber media converter has the ability of
auto-negotiation and works in 1000M full-duplex mode (cannot work in 1000M half-duplex
mode). And the electrical port of other device should enable auto negotiation to make sure
of normal communication.
7
Raisecom Technology Co., Ltd
8
Raisecom Technology Co., Ltd
1. Make sure that fiber optical media matches the media converter.
RC602-GE (A)-M must use multi mode optical fiber and the connector should be DSC.
RC602-GE (A)-S1/2/3 must use single mode optical fiber and the connector should be
DSC.
Single mode optical interface of RC602-GE (A)-SS13/5 must use single mode optical fiber
medium and the connector should be SC/PC.
2. Fiber type
Fiber for multi mode optical interface:
62.5/125um multi mode optical fiber or 50/125um multi mode optical fiber
Fiber for single mode optical interface:
9/125um single mode optical fiber
3. Electrical interface: Connecting media converter with Cat.5 twisted-pair which
should not be longer than 100m. Refer to 4.2. Connect MC with Other Devices
(Electrical Port) in Chapter 2 for details.
4. Installation of chassis (refer to the following figure)
Note: Brackets used to fix the chassis are in the accessory box. If you use the bracket’s
rear holes to attach brackets to the chassis, there will be 3cm space between chassis front
panel and cabinet front panel; and if you use the bracket’s front holes, the front panel and
the rack will be at the same level vertically.
5. Install the DC power supply:
There are three connectors of DC power supply: -48V, Ground, 0V, which must be
connected to -48 power supply cable, protection ground and 0V power supply cable
respectively.
9
Raisecom Technology Co., Ltd
48v G 0v
6. Ambience
Operating temperature: 0-45℃
Humidity: 5%~90% (non-condensing)
7. Power supply requirement:
Single slot chassis: 220V/50Hz AC or –48V DC
16-slot chassis: 220V/50Hz AC or –48V DC
8. Dimensions
Single slot chassis: 155 (W) x 39 (H) x 120mm (D)
16-slot chassis: 442 (W) x 130.5 (H) x 350mm (D)
10
Raisecom Technology Co., Ltd
6. Dip-Switch
11
Raisecom Technology Co., Ltd
SW1 is used for setting up the type of device. Please refer to the following table for
details:
SW1-1 SW1-2 SW1-3 SW1-4 Module type
ON ON ON ON RC602-GE(A)-M
ON ON ON OFF RC602-GE(A)-S1
ON ON OFF ON RC602-GE(A)-S2
ON ON OFF OFF RC602-GE(A)-S3
ON OFF ON ON RC602-GE(A)-SS13
ON OFF ON OFF RC602-GE(A)-SS15
Note: Customers are not permitted change the state of type configuration DIP switches
SW1.
12
Raisecom Technology Co., Ltd
7. Network management
The RC602-GE (A)-Master status information can be viewed, controlled, and configured
through network management software. RC602-GE(A)-Slave can be controlled and
configured through RC602-GE (A)-Master
Available status information of RC602-GE (A) command is:
Numb Status name, control and Value Controllable features
er configuration items
RC602-GE-REV_A-Mast
1 Module type Not controllable
er
2 Remote management Enable/disable Controllable
Optical-to-electrical port
3 Enable/disable Controllable
fault pass through
Electrical-to-optical fault
4 Enable/disable Controllable
pass through
5 Electrical port: Link status Up/Down Not controllable
6 Electrical port: control Open/close Controllable
7 Electrical port (FP): control Open/close Not controllable
8 Optical module type M,S1,S2,S3,SS15 Not controllable
9 Optical port: Link status Up/Down Not controllable
10 Optical port: control Open/close Controllable
11 Optical port (FP) : control Open/close Controllable
12 Optical port(FR): control Open/close Controllable
13 Optical port: SD status Normal/abnormal Not controllable
Optical port: RX-to-TX fault
14 Enable/disable Controllable
return
Traffic statistic: receiving the
15 number of bits on electrical Not controllable
port
Traffic statistic: transmitting
16 the number of bits on Not controllable
electrical port
13
Raisecom Technology Co., Ltd
In the above table, the configurable items can be configured through “config module”
command. These items includes: turn on or turn off electrical port, RX-to-TX fault pass
through, optical-to-electrical port fault pass through, electrical-to-optical port fault pass
through, etc.
Local module can be reset through “Reset module” command. After reboot, the working
mode and status will remain the same as that before reboot.
14
Raisecom Technology Co., Ltd
8. Q&A
15
Raisecom Technology Co., Ltd
16