RC602-GE (A) Remote Management 1000M Ethernet Media Converter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

RC602-GE (A) remote management 1000M

Ethernet media converter

User Manual

Raisecom Technologies Co., Ltd


Jan, 2006
Raisecom Technology Co., Ltd

Cautions
Please read the following notices carefully before

installing and using the device, Raisecom does not

respond to any loss that caused by violating safety

notice.

RC602-GE series provide optical port, and the Tx laser

may damage your eyes. So do not look into the optical

port, and if the optical port is not used please insert

the plug.

RC602-GE series are integrated devices that have

precise elements, please avoid violent shakes and

impacts, and do not disassemble or maintain the

devices yourself. If it is required, please do it under

the guide of our technical staff following in the steps

of anti static. Please contact us if there is any need.

There must be grounding protection for the sake of

safety; do not disassemble the device yourself, we

regard it as you waiver your rights of repair guarantee.

1
Raisecom Technology Co., Ltd

Content
1. Overview............................................................................................................. 3
1.1. Introduction .............................................................................................. 3
1.2. Features................................................................................................... 3
1.3. Ordering information ................................................................................ 3
2. Parameters ......................................................................................................... 4
2.1. Device specifications................................................................................ 4
2.2. Optical interface specifications................................................................. 4
3. Front view and indicators .................................................................................... 5
3.1. Front view of RC602-GE (A) .................................................................... 5
3.2. Front view 16-slot chassis........................................................................ 6
4. Connection configuration .................................................................................... 7
4.1. Interconnecting Devices........................................................................... 7
4.2. Connect MC with Other Devices (Electrical Port)..................................... 7
4.3. Working Mode Configuration (Electrical Port) .......................................... 7
4.4. Connecting MC with Other Devices (optical port)..................................... 8
5. Installation & preparation .................................................................................... 9
6. Dip-Switch..........................................................................................................11
6.1. Explanation of function configuration DIP-switch ....................................11
6.2. Introduction of type configuration DIP switches...................................... 12
7. Network management....................................................................................... 13
7.1. View the module status .......................................................................... 13
7.2. Configure the module............................................................................. 14
7.3. Reset the module ................................................................................... 14
8. Q&A .................................................................................................................. 15

2
Raisecom Technology Co., Ltd

1. Overview

1.1. Introduction

RC602-GE is 1000M Ethernet media converter that supports both local and remote
management, and the longest transmission distance is 100km. With NView iEMS network
management local RC602-GE can be wholly controlled and configured.

1.2. Features

‹ RC602-GE (A) has Master and Slave working mode. Master is working in central site,
Slave is working in remote site. The working mode can be changed through the
DIP-switch.
‹ Transport Ethernet data at rate of 1000M transparently. Requirement of different
transmission distance and different wavelength can be satisfied.
‹ Flexible network fault management function, which provides optical port RX-to-TX
fault-pass-through, Optical-to-electrical fault-pass-through and Electrical-to-optical
fault-pass-through to satisfy different customers’ needs.

1.3. Ordering information

Part number Description


RC602-GE(A)-M central/remote module,1000Mbps,multimode,0-550m,RJ45/DSC
RC602-GE(A)-S1 central/remote module,1000Mbps,singlemode,0-25km,RJ45/DSC
RC602-GE(A)-S2 central/remote module,1000Mbps,singlemode,10-60km,RJ45/DSC
RC602-GE(A)-S3 central/remote module,1000Mbps,singlemode,25-120km,RJ45/DSC
remote module,1000Mbps,singlemode,single strand fiber,0-25km,
RC602-GE(A)-SS13
RJ45/SC
central module,1000Mbps,singlemode,single strand fiber,0-25km,
RC602-GE(A)-SS15
RJ45/SC

3
Raisecom Technology Co., Ltd

2. Parameters

2.1. Device specifications

Dimension (H×W×D) 25mm×76mm×170mm


Optical interface SC/PC, SC/PC
Work temperature (℃) (0,45)
Storage temperature (℃) (-40,80)
Power consumption (W) Typical value: 4W
Humidity 5%~90% non-condensing

2.2. Optical interface specifications

Wave Tx Output Cable Attenuatio


Rx Saturation
Model Interface Length Power Length n
dBm
nm dBm Km dB/Km
RC602-GE(A)-M DSC 850 -10 - -3 < -15 0 - 0.55 3
RC602-GE(A)-S1 DSC 1310 -10 - -3 < -23 0 - 25 0.5
-3 -
RC602-GE(A)-S2 DSC 1550 < -20 10 - 60 0.25
+2(DFB)
-3 -
RC602-GE(A)-S3 DSC 1550 < -30(APD) 25 - 100 0.25
+2(DFB)
RC602-GE(A)-SS1
SC 1310 -10 - -3 <-20 0 - 20 0.5
3
RC602-GE(A)-SS1
SC 1550 -10 - -3 <-20 0 - 20 0.5
5

4
Raisecom Technology Co., Ltd

3. Front view and indicators

3.1. Front view of RC602-GE (A)

LNK TX RX ACT LNK TX

RMD PWR RX

The explanation of RC602-GE indicators:

Interfa Indicator Name Indicat Explanation of Indicator


Optica Optical RX ON, optical RX link works properly;
LNK
l Indicator OFF, optical RX link is abnormal
interfa
ce Indicat
Indicator Name Explanation of Indicator
Interfa or
ce
Remote
Fixed on: remote device is managed;
management RMD
Fixed off: remote device is not managed.
indicator
Electrical link ON, electrical port works properly;
LNK
Electri indicator OFF, electrical port is abnormal
cal Electrical port Tx ON, electrical port is transmitting data;
TX
interfa indicator OFF, electrical port is not transmitting data.
ce Electrical port Rx ON, electrical port is receiving data;
RX
indicator OFF, electrical port is not receiving data
Power Power supply ON, power supply works properly;
PWR
supply indicator OFF, power supply is abnormal

5
Raisecom Technology Co., Ltd

3.2. Front view 16-slot chassis

Explanations of the indicators on 16-slot chassis are as follows:


PWR indicator: ON, chassis power supply works normal.
PS1-5V indicator: OFF, power supply PS1 for modules works normal, otherwise
abnormal.
PS1-12V indicator: OFF, power supply PS1 for fans works normal, otherwise
abnormal.
PS2-5V indicator: OFF, power supply PS2 for modules works normal, otherwise
abnormal.
PS2-12V indicator: OFF, power supply PS2 for fans works normal, otherwise
abnormal.

6
Raisecom Technology Co., Ltd

4. Connection configuration

4.1. Interconnecting Devices

Please follow the connection rules in the following table when interconnecting RC602-GE
(A) series media converters; otherwise they may not work properly.
Central site Remote site

RC602-GE(A)-M-Master RC602-GE(A)-M-Slave

RC602-GE(A)-S1-Master RC602-GE(A)-S1-Slave

RC602-GE(A)-S2-Master RC602-GE(A)-S2-Slave

RC602-GE(A)-S3-Master RC602-GE(A)-S3-Slave

RC602-GE(A)-SS15-Master RC602-GE(A)-SS13-Slave

4.2. Connect MC with Other Devices (Electrical Port)

RC602-GE (A) series copper to fiber media converters have the function of MID/MIDX
auto-sensing, so they can connect with other devices through straight-though cable or
crossover cable.
Media Other device Connection type of
RJ45 port
converter
Media converter Switch Straight-through,
crossover
Media converter HUB Straight-through,
crossover
Media converter Router Crossover,
straight-through
Media converter NIC Crossover,
straight-through

4.3. Working Mode Configuration (Electrical Port)

Electrical port of RC602-GE (A) series copper to fiber media converter has the ability of
auto-negotiation and works in 1000M full-duplex mode (cannot work in 1000M half-duplex
mode). And the electrical port of other device should enable auto negotiation to make sure
of normal communication.

7
Raisecom Technology Co., Ltd

4.4. Connecting MC with Other Devices (optical port)

The following conditions must be satisfied:


1. The same wavelength (single strand dual wavelength MC is not included)
2. The same data rate
3. Matched optical power
4. Gigabit Ethernet protocol (IEEE 802.3z Gigabit Ethernet)
Optical port is forced to work in 1000M full duplex and auto negotiation function is
disabled.

8
Raisecom Technology Co., Ltd

5. Installation & preparation

1. Make sure that fiber optical media matches the media converter.
RC602-GE (A)-M must use multi mode optical fiber and the connector should be DSC.
RC602-GE (A)-S1/2/3 must use single mode optical fiber and the connector should be
DSC.
Single mode optical interface of RC602-GE (A)-SS13/5 must use single mode optical fiber
medium and the connector should be SC/PC.
2. Fiber type
Fiber for multi mode optical interface:
62.5/125um multi mode optical fiber or 50/125um multi mode optical fiber
Fiber for single mode optical interface:
9/125um single mode optical fiber
3. Electrical interface: Connecting media converter with Cat.5 twisted-pair which
should not be longer than 100m. Refer to 4.2. Connect MC with Other Devices
(Electrical Port) in Chapter 2 for details.
4. Installation of chassis (refer to the following figure)

19" standard chassis

Note: Brackets used to fix the chassis are in the accessory box. If you use the bracket’s
rear holes to attach brackets to the chassis, there will be 3cm space between chassis front
panel and cabinet front panel; and if you use the bracket’s front holes, the front panel and
the rack will be at the same level vertically.
5. Install the DC power supply:
There are three connectors of DC power supply: -48V, Ground, 0V, which must be
connected to -48 power supply cable, protection ground and 0V power supply cable
respectively.

9
Raisecom Technology Co., Ltd

48v G 0v

6. Ambience
Operating temperature: 0-45℃
Humidity: 5%~90% (non-condensing)
7. Power supply requirement:
Single slot chassis: 220V/50Hz AC or –48V DC
16-slot chassis: 220V/50Hz AC or –48V DC
8. Dimensions
Single slot chassis: 155 (W) x 39 (H) x 120mm (D)
16-slot chassis: 442 (W) x 130.5 (H) x 350mm (D)

10
Raisecom Technology Co., Ltd

6. Dip-Switch

Functions of RC602-GE (A) series copper-to-fiber media converter can be configured by


the function configuration DIP switches. The modular media converter has function
configuration DIP switches SW2 and function configuration DIP switches of standalone
media converter is SW2 which is on the rear panel. Besides, modular media converter
also has a type configuration switch SW1.

6.1. Explanation of function configuration DIP-switch

SW2 is a 8-bit DIP-switch and the 8 bits are: optical-to-electrical fault-pass-through


enable/disable, electrical-to-optical fault-pass-through enable/disable, optical port
RX-to-TX fault-pass-through enable/disable and remote management enable/disable.
Please refer to the following table for details:
Switch Function Status Explanation
Optical port RX-to-TX fault-pass-through
OFF
disabled
SW2-1 Fault return
Optical port RX-to-TX fault-pass-through
ON
enabled
SW2-2 Reserved -- --
SW2-3 Reserved -- --
SW2-4 Reserved -- --
Remote OFF Enable
SW2-5
management ON Disable
OFF RC602-GE(A)-Master
SW2-6 Master/slave
ON RC602-GE(A)-Slave
Optical-to-electric Optical-to-electrical fault-pass-through
OFF
al disabled
SW2-7 fault-pass-through Optical-to-electrical fault-pass-through
ON
enable/disable enabled
Electrical-to-optica Electrical-to-optical fault-pass-through
OFF
l disabled
SW2-8
fault-pass-through Electrical-to-optical fault-pass-through
ON
enable/disable enabled

SW2 ex-factory setting:


1 2 3 4 5 6 7 8
ON
OF
█ █ █ █ █ █ █ █
F
Note: SW2-6 ex-factory setting is OFF, RC602-GE (A)-Master

11
Raisecom Technology Co., Ltd

6.2. Introduction of type configuration DIP switches

SW1 is used for setting up the type of device. Please refer to the following table for

details:
SW1-1 SW1-2 SW1-3 SW1-4 Module type
ON ON ON ON RC602-GE(A)-M
ON ON ON OFF RC602-GE(A)-S1
ON ON OFF ON RC602-GE(A)-S2
ON ON OFF OFF RC602-GE(A)-S3
ON OFF ON ON RC602-GE(A)-SS13
ON OFF ON OFF RC602-GE(A)-SS15
Note: Customers are not permitted change the state of type configuration DIP switches
SW1.

12
Raisecom Technology Co., Ltd

7. Network management

7.1. View the module status

The RC602-GE (A)-Master status information can be viewed, controlled, and configured
through network management software. RC602-GE(A)-Slave can be controlled and
configured through RC602-GE (A)-Master
Available status information of RC602-GE (A) command is:
Numb Status name, control and Value Controllable features
er configuration items
RC602-GE-REV_A-Mast
1 Module type Not controllable
er
2 Remote management Enable/disable Controllable
Optical-to-electrical port
3 Enable/disable Controllable
fault pass through
Electrical-to-optical fault
4 Enable/disable Controllable
pass through
5 Electrical port: Link status Up/Down Not controllable
6 Electrical port: control Open/close Controllable
7 Electrical port (FP): control Open/close Not controllable
8 Optical module type M,S1,S2,S3,SS15 Not controllable
9 Optical port: Link status Up/Down Not controllable
10 Optical port: control Open/close Controllable
11 Optical port (FP) : control Open/close Controllable
12 Optical port(FR): control Open/close Controllable
13 Optical port: SD status Normal/abnormal Not controllable
Optical port: RX-to-TX fault
14 Enable/disable Controllable
return
Traffic statistic: receiving the
15 number of bits on electrical Not controllable
port
Traffic statistic: transmitting
16 the number of bits on Not controllable
electrical port

13
Raisecom Technology Co., Ltd

7.2. Configure the module

In the above table, the configurable items can be configured through “config module”
command. These items includes: turn on or turn off electrical port, RX-to-TX fault pass
through, optical-to-electrical port fault pass through, electrical-to-optical port fault pass
through, etc.

7.3. Reset the module

Local module can be reset through “Reset module” command. After reboot, the working
mode and status will remain the same as that before reboot.

14
Raisecom Technology Co., Ltd

8. Q&A

Fault phenomenon Resolve methods


1 Optical LNK indicator turns off Check whether the input optical power of
optical interface is normal.
2 There is packet loss and optical First check whether the input optical power of
connection breaks off optical interface is normal, if it is normal, check
sometimes if the rate and duplex mode of the two sides
match each other. If not set the relative DIP
switches.
3 Network management is not Make sure that the EMS version is 1.15
available (build2)6.6.0 or higher and MCU chip is
secured to the main board.
4 Optical interface Link Down Make sure both sides are powered on and
fiber is connected correctly and when
RC602-GE works in pairs, the Rx-to-Tx fault
pass through function is not enabled at both
sides at the same time.
5 Electrical interface Link Down Make sure that UTP complies with 568-a and
568b standards, otherwise they cannot
communicate normally.
Make sure both side devices are powered on
and the electrical port is not shutdown through
network management.
6 When connect with other factory Make sure that the optical port of other factory
device, the LNK indicator is device works in 1000M full-duplex.
steady ON but the two devices
cannot communicate normally.
7 When the remote device can not Firstly please check SW2-5 to make sure if it is
be checked enable, then please check SW2-6 if it is slave
setting.

15
Raisecom Technology Co., Ltd

@2006 Raisecom Technology Co., Ltd.


All trademarks are the property of their respective owners.
Technical information may be subject to change without prior notification.

16

You might also like