4
5
6 Size 203,2 -- 3657,6 mm Type BEM Hor Connected in 1 parallel 2 series
7 Surf/unit(eff.) 19,7 m² Shells/unit 2 Surf/shell (eff.) 9,9 m²
8 PERFORMANCE OF ONE UNIT
9 Fluid allocation Shell Side Tube Side
10 Fluid name
11 Fluid quantity, Total kg/h 488 1337
12 Vapor (In/Out) kg/h 488 488 1337 1337
13 Liquid kg/h 0 0 0 0
14 Noncondensable kg/h 0 0 0 0
15
16 Temperature (In/Out) °C 25 250 265 174,46
17 Dew / Bubble point °C 133,92 133,92
18 Density Vapor/Liquid kg/m³ 5,4 2,94 1,22 0,87
19 Viscosity cp 0,008 0,014 0,0187 0,015
20 Molecular wt, Vap 44,09 44,09 18,01 18,01
21 Molecular wt, NC
22 Specific heat J/(kg K) 1720,26 2635,65 2024,24 2061,2
23 Thermal conductivity W/(m K) 0,0133 0,0486 0,0396 0,031
24 Latent heat J/g
25 Pressure (abs) atm 3 2,863 3 1,768
26 Velocity m/s 8,45 107,78
27 Pressure drop, allow./calc. atm 0,493 0,137 0,493 1,232
28 Fouling resistance (min) m² K/W 0,00045 0,0001 0,00013 Ao based
29 Heat exchanged 66412 W MTD corrected 25,44 °C
30 Transfer rate, Service 132,4 Dirty 143,9 Clean 156,9 W/(m² K)
31 CONSTRUCTION OF ONE SHELL Sketch
32 Shell Side Tube Side
33 Design/vac/test pressure:g atm 3,402 3,402
34 Design temperature °C 287,78 304,44 T1 S2