Variant
Current differential - 2 ended standard version 1
Earth current input
0.1-40 Ion A
0.01-8 Ion B
0.002-1 Ion C
Protection communication
EIA (RS) 232 single channel A
EIA (RS) 485 single channel B
850nm single channel C
1300nm multi-mode / single channel (43dB) F
1300nm single-mode / single channel (43dB) G
Auxiliary voltage Digital input voltage
48 - 250 Vdc / 48 - 240 Vac 105 - 145 Vdc H
48 - 250 Vdc / 48 - 240 Vac 24 - 250 Vdc T
48 - 250 Vdc / 48 - 240 Vac 110 Vdc -30%/ +20% V
48 - 250 Vdc / 48 - 240 Vac 220 Vdc -30%/ +20% W
24 - 250 Vdc / 48 - 240 Vac 24 - 250 Vdc / 24 - 240 Vac Z
Communication protocol
MODBUS 1
IEC 60870-5-103 3
DNP3 4
Modbus TCP/IP 4) (with voltage V&W only) 6
IEC60870-5-103 Eth 4) (with voltage V&W only) 7
Language
French 0
English / American 1
Spanish 2
German 3
Italian 4
Russian 5
Polish 6
Portuguese 1) 7
Dutch 1) 8
Czech 1) A
Hungarian 1) B
Greek 1) C
Chinese 2) D
Turkish 1) E
Platform
SE look&feel Phase 2 2
SE look&feel Phase 2 with larger LCD 3
Software
Major version
Minor version
Mounting option 3)
None (default) 3) 0
Pre-fixed HMI (no withdrawability) 1
Sealed cover 3) 2
Pre-fixed HMI + Sealed cover 3
NOTES :
1)
Not available
2)
Only available with Phase 2 Hardware with larger LCD
3)
Not available with Auxiliary voltage / Digital input code T
4)
For China only. Inquiry out of China, please contact product manager before tendering.
08/22/2019
Order form configurator MiCOM P521
Ready-to-use configuration
1-3 4 5 6 7 8 9 10 11 12 13 14
Communication protocol
MODBUS
IEC60870-5-103 1
DNP3
08/22/2019
Issue : 001 - Derived from existing Cortec/Configurator, reformated as other Px2x - 06/10/09
Issue : 002 - Modified following comments from G Giannitelli and Zhemin YU - 20/10/09
Issue : 003 - Modified further, following comments from G Giannitelli - 21/10/09
Issue : 004 - Auxiliary & digital input voltage options A & F removed - 13/11/09
Issue : 005 - Phase 1 software version restricted to text only, Auxiliary Voltage for options T, V & W corrected in Dat
removed from BOM - 17/11/09
Issue : 006 - SW Release V5.A on CID JLIU-7YR4CS - 15/12/09
Issue : 007 - SW Release V11.A on CID SBIA-7ZWGKU - 29/1/10
Issue : 008 - ZG1087002, Protection option 'E' suppressed on CID SBIA-82GHDY - 12/2/10
Issue : 009 - Addition of EGN0060002 : Chinese secondary cover as per SBIA-83SDBL - 29/03/10
Issue : 010 - Pilot Calculator and Scheme sheets added back in, were on phase 1 only cortec - 29/06/10
Issue : 011 - Phase 1 SW to V5.B ; Warning stickers added to BOM ; Both as per SBIA-86J9DR - 05/07/10
Issue : 012 - 518414113 replaces 518414111 as per SBIA-88GCW3 - 16/09/10
Issue : 013 - SW Release V12.B + suppression of protection option 'D' as per SBIA-87QD8Z - 18/10/10
Issue : 014 - Auxiliary Voltage rating for Universal Power Supply option, 'Z', amended to 24-250Vdc/48-240Vac as p
Issue : 015 - Rebranded SW versions added (V5.C for ph1, V12.C for ph2) as per SHAL-8EJJB8 - 01/04/11
Issue : 016 - Software V12.D as per YLIU-8HW57R, V12.C invalidated - 23/06/11
Issue : 017 - Phase 1 removed from configurator, SW availability updated as per rationalisation project - 24/06/11
Issue : 018 - SW version V13.A released as per SBIA-8QKEJE - 24/01/12
Issue : 019 - Tendering sheet added - 23/02/12
Issue : 020 - As per SBIA-8ZYH6M - SW version V11.A & V12.D invalidated for Chinese language option - 17/12/12
Issue : 021 - As per SBIA-97NCKT - SW version V13.B released - 24/05/13
Issue : 022 - Equipped PCBAs introduced - 13/08/13
Issue : 023 - Per BLII-9ARDQN - SW version V13.C released along with Comms options 6 & 7 - 03/09/13
Issue : 024 - SW version (V11.A) obsoleted per SBIA-9AYGDB- 10/09/13
Issue : 025 - As per RKLI-9EQ52G - SW version V13.D released - 22/01/14
Issue : 026 - As per SBIA-9FEBK8 - SW versions V13A & V12D removed from offer - 30/01/14
Issue : 027 - As per RKLI-9KRAXG - Graphical Display option with SW V13.B withdrawn - 15/06/14
Issue : 028 - As per YBWG-9L7CB9 - Auxiliary voltage range on Cortec sheet corrected - 01/07/14
Issue : 029 - As per RKLI-9N46JV - SW version V13.E released ; V13.D unavailable now with graphical LDC - 02/0
Master Text
P521B0AZ112DE0
This calculator determines the minimum pilot wire isolation level required
given the total line length, the maximum Earth Fault current that can occur
and the type of cable.
1
Select the type of Fibre Optic…
Multi-mode Select the type of Fibre Optic…
Single-Mode
5
6
7
8
9
10
11
12
13
14
15
16
0
0
0
0
0
0
0
0
0
0
0
0
0
0