Wiring
Length Size
Up to 500m 2-core or 3-core, 0.75mm2
Type
This symbol is used to identify action which, if carried out in an incorrect ignoring this indication,
[ Hydro unit ] [ Electric component box ]
could lead to serious personal injury or even death.
,, CAUTION
This symbol is used to identify action which, if carried out in an incorrect ignoring this indication,
could lead to serious human injury or property damage.
• After installation work has been completed, perform a trial operation of the equipment in order
to ensure that it is operating normally, and then hand over to the customer and ask to keep
this Safety Precautions and Installation Instruction.
. .
,L WARNING
Installation of accessory parts should be performed either by personnel from this dealer
where it was purchased or by specialist installation technicians.
• Incorrect installation by unqualified personnel can result in electric shock, fire or abnormal operation.
Reassembling, repair, or modification of this accessory parts is strictly forbidden.
• Failure to follow these directions can result in inflammation, earth leakage or abnormal operation
causing electric shock or injury.
Use the specified wires for wiring connect the terminals securely fix. To prevent external
forces applied to the terminals from affecting the terminals. How to install
Do not install a location where flammable gasses may be present. (1) Be sure to turn off the power switch before installing.
• Fire may break out should flammable gas leak into the vicinity of the parts. (2) Stick the attached terminal label on the board as
Repair of the accessory parts must also carried out by personnel from dealer where it was purchased. shown in the figure on the right.
• Incorrect installation by unqualified personnel can result in electric shock, fire or abnormal operation.
(3) Place this P.C. board by using 4 supports to fix the
In case of installation of option PC Board, make sure that the means for disconnection board.
\ must be incorporated in the fixed wiring in accordance with the wiring rules.
There are four installation holes to place the support
on the upper side of the electric component box.
Feature "TCB-PCM03E" is used for the following external master controls (4) Connect the P.C.board (TCB-PCM03E) PJ17 and
1. Cooling / Heating thermostat input hydro unit main control board CN210 and CN211 with
2. Forced - stop signal input connection cable.
Refer to the "Function/Electric wiring diagram" for feature of the each controls because connecting way is Connecter on interface P.C. board is different
different according to the control. according to the purpose. Terminal label
CAUTION)
CN210 PJ17 S2
• Be sure to prepare non voltage continuous point of contact for each terminal. 9
• Supplementary Insulation must be added to user touchable part of switches.