WHEREAS, in the LTO's manda te to ins p ect and r egiste r m otor vehicles,
Section 16 of R.A. 41 36 provides that,
WHEREAS, the LTO, under R.A. No. 874 9 (The Philippine Clean Air Act},
is likewise m and a ted to enforce the required emission s tandards for motor
vehicles.
NOW, THEREFORE, premises consider ed, the LTO h ereby promulga tes
these Guidelines for the Authorization of PMVICs , as follows :
1
S ECTION 1. PROJECTED NATIONWIDE LANE REQUIREMENT
B . A PMVIC shall h ave a minimum of two (2) Light Vehicle (LV) lanes and
two (2) Motorcycle (MC) lanes with a total contiguous lot area of a t
least One Thousand Five Hundred square meters (1,500 sq.m.).(See
Annex "C"). Additional ·lanes maybe a u thorized provided that they
shall have a corresponding area of 180 sq. meters for an LV lane and
28 sq. meters for an MC lane.
2
National Capital .Region (34 sites )
Mandaluyong (2)
Marikina(l)
Pasig(2)
Diliman(l)
La Loma(2)
Novaliches(2)
Quezon City (3)
Caloocan (2)
Malabon (1)
Valenzuela (2)
Manila (4)
Muntinlupa (2)
P.ara n a que (2)
Las Pinas (2)
Makati (2)
Taguig (1)
Pasay (1)
San Juan (1)
Pateros (1)
REGION 1 (9 sites)
Laoag City(Ilocos Norte) (1)
Vigan City (Ilocos Sur) (1) .
Candon City (!locos Sur) (1)
Agoo(La Union) (1)
San Ferna ndo City (La Union)(l)
i
. ·'' Dagupan City (Pa n gasinan) (1)
Within Lingayen and Alaminos, Pangas inan
{ 1)
Within Sa..'1. Carlos and Urdan eta,
Pan ga sinan (1)
Within Rosales and San Nicola s,
Pa ngasinan (1)
REGION 2 (3 sites)
Tuguegarao City (Cagayan) (1)
Ca uayan or Santiago City (Isabela) (1)
Bayombong, Nueva Vizcaya (1)
3
' --·
REGION 4B (2 sites)
Cala pan, Oriental Mindoro (1)
Puerto Princesa City(Palawan) (1)
REGION 5 (5 sites)
.
·'
Daet, Camarin e s Norte (1)
Pili, Camarines Su r (1)
Ligao, Albay (1)
Sorsogon City (Sorsogon) (1)
Pamplona, Camarines Sur (1)
REGION 6 (9 sites)
Bacolod City(Negros Occidental) (2)
Kabankalan City(Negros Occidental) (1)
Iloilo City (Iloilo) (2)
· Roxas City (Capiz) (1)
Kalibo, Aklan (1)
San Jose, Antique (1)
Passi City (1)
4
Carcar City (Cebu) (1)
Mandaue City (Cebu)(2)
Naga City (Cebu) (1)
Danao City (Cebu) (1)
Tagbilaran City (Bohol) (1)
Tubigon, Bohol (1)
Taliban Bohol (1)
Dumaguete City (Negros Oriental) (2)
Bais City (Negros Oriental) (1)
. •:
REGION 8 (4 sites)
Tacloban City (Leyte) (1)
Ormoc City (Leyte) (1)
Maasin City (Southern Leyte) (1)
Calbayog City (Western Samar) (1)
REGION 9 (5 sites)
Zamboanga City Special Economic Zone,
San Ramon, Zamboanga City (1)
Zamboanga City (1)
Pagadian City (Zamboanga del Sur) (1)
Dipolog City (Zamboanga del Norte) (1)
Ipil, Zamboanga Sibugay (1)
REGION 1 0 (6 sites)
Ozamis City (Misamis Occidental) (1)
Gingoog City (Misamis Oriental) (1)
Iligan City (Lanao del Norte) (1)
Ma laybalay City (Bukidnon) (1)
Cagayan de Oro City (Cagayan de Oro) (1)
Mabajao, Camiguin Province (Camiguin) (1)
REGION 11 (8 sites)
Davao City (Davao) (2)
Tagum City (Davao del Norte) (1)
Panabo City (Davao del Norte) (1)
Malita, Davao Occidental (1)
Nabunturan, Compostela Valley (1)
Mati City (Davao Oriental)(!)
Digos City (Davao del Sur) (1)
REGION 12 (6 sites)
General Santos City (South Cotabato) (1)
Cotabato City (Cotabato) (1)
Koronadal City (South Cotabato) (1)
Kidapawan City (Cotabato) (1)
5
Tacurong City (Suitan Kudarat) (1)
Municipality of Midsaya.p, Cotabato ( 1)
CAR (2 sites)
Baguio City(Benguet) (1)
Kalinga (1)
CARAGA (3 sites)
Butuan City, Agusan Del Norte (1)
Surigao City (Surigao del N_o rte) (1)
Tandag City (Surigao del Sur) (1)
E . The LTO shall review the projected la:ne or PMVICs required every 2
years or should the need arise as recommended by the Assistant
Secretary,LTO and approved by the Authorization Committee.
1. Letter of Intent;
2. Duly accomplished application form, under oath;
3. Location map and layout of the proposed PMVIC, including
dimensions;
4. Bank Certificate of Deposit in the amount of not less t han
Pl0,000,000.00 or L.e tter of Credit or its equivalent;
5. Transfer Certificate of Title in the name of the applicant or
Contractto lease with a minimum lease period of ten (10) years;
6. Payment of Application Fee of Php. 50,000.00 which is non-
refundable;
7. Profile of the applicant, joint venture partners, or incorporators
with sworn statement to organize and register as such once the
Provisional Authority is issued; and
8. Brief descrip tion of the MVIS equipment to be installed with
manufacturer's brochures, manuals and certificate of delivery
schedule from the manufacturer.
7
SECTION 4 . Operationalization of PMVIC
The applicant within forty-five (45) days from receipt of the Provisional
Authority, s ubmit the documents enumerated in Section 2, paragraph
B h ereof. Upon determination of completeness and a u thenticity of the
documents submitted, a Notice to Proceed ·construction shall be
issued to the applicant. Upon receipt of the a pplicant of the said
notice, the latter shall have a period of"one-h u n dred and fifty days
(1 50) to complete the PMVIC facility.
Upon completion of the PMVIC facility within the required period, the
applicant shall serve a Notice of Compliance to th e Authorization
Committee. The Authorization Committee upon receipt thereof shall
direct the Inspection Team to conduct inspection of the PMVIC
facility.
A. Documentary Requirements
1. Duly accomplished application form for Renewal, under oath;
2. Original copy of the Authorization Certificate;
3. Original LTO Certificate of MVIT;
4. TES DA Certificate of the MVIT;
5. Certified true copy of Mayor's or Business Permit;
6 . Latest Income Tax Return for the immediately preceding year duly
stamped a nd received by the BIR;
7. Certificate of calibration issued by accredited calibration
laboratories (Coordinate with DTI-PAB);
8. Payment of Renew.a l Fee of Php.50,000.00 which is non-
refun dable; and
9. Audited financial statement of the immediately preceding year.
SECTION 7. PERSONNEL
1. Manager
a. Shall be responsible for the overall management and supervision
of the PMVIC;
b. Shall ensure .that the actual inspection is in accordance with the
required procedures and processes;
c. Shall ensure that the inspection center is interconnected to the
LTO central database;
d. Shall be responsible for the management of data control
equipment such as computers, servers, etc., and the p rinting
and releasing of Motor Vehicle Inspection Stickers/
Certifications/ Reports; and
e. Shall also act as Releasing Officer.
The PMVIC shall have at least three (3) authorized MVIT per LV
lane and Two (2) authorized MVIT per motorcycle lane.
3. Clerk
4. One Inspector Aide (1)
5. Two Security Personnel (2) ;
6. ·Parking Attendant (1)
1. HEADLIGHT TESTER
i. Automated headlight tester
ii. Automatic detection of the headlight
m. Measurement of the luminous intensity, vertical and
horizontal deviation.of the light beam
10
iv. Steel ,base mounted with rollers
v. Capable of measuring all types of headlight
vi. Automatic pass/ fail judgment
vii.Operating conditions 0 - 40°C
vm. Sensor type - Photocell Camera system
ix. Process indicator (digital display/Color LCD)
x. PC interface or its equivalent forinterfacing/IT
connectivity
xi. Precise measurement of different ligh t (LED, Xenon)
sources· in real time
3. SIDESLIPTESTER
i. Automated si.deslip tester
ii. Automatic pass/ fail judgment
iii. Type: Single/Dual plate configuration
iv. Maximum load per axle 3,000 kgs
v. Mounting plate: Heavy duty structural steel
vi. Sensor type e.g., Linear Transducer
vn. Beginning of measurement after optical passage
detection
viii. PC interface or its equivalent for interfacing/IT
connectivity
ix. Fast measurement within 2 seconds precise values,
4. SPEEDOMETER TESTER
i. Automated speedometer tester
ii. Type: Rolier speedometer tester
11
m. Sen sor type: Digital speed sensor
1v. Frame: Heavy duty structural steel
v. Automatic pass/fail judgment
vi. 780mm-2200mm minimum-maximum track
vii. Maximum load per ~le 3,000 kgs
viii. Lifting method: Hydraulic System/ Pneumatic System
: 5. EMISSION TESTER
·' •
l
1. Type: Gas analyzer on trolley for mobility
11. 5 gas analyzer
111. Automatic Pass/Fail judgement
8. SUSPENSION TESTER
1. Type: Dual p late configuration
ii. Maximum load per axle - 3,500 kgs
iii. Frame: Heavy duty stru ctural steel
1v. PC in terface or its equivalent for interfacing/IT
connectivity
v. Network capable suspension tester
vi. With axle weighting capability
12
10. SOUND LEVEL METER (SONOMETER)
i. Portable
11. Internal Oscillation Calibration
iii. With positioning tripod stand
iv. Digital display
B. FOR MOTORCYCLES/TRICYCLES ·
1. HEADLIGHT TESTER
i. Automatic detection of the headlight
ii. Measurement of the intensity, vertical and horizontal
deviation of the lightbeam
iii. Steel base mounted w ith rollers
iv. Capable of measuring all types of headlight
v. Automatic pass/failjudgment
v1. Operating conditions 0 - 40°C ·
vii. Sen sor type - Ph otocell Camera system
viii. Process. indicator (digital display/ Color LCD)
ix. PC interface or its equivalen t for interfacing/IT
connectivity
x. Precise measurement of different light (LED, Xenon)
sources in real time
3. EMISSION TESTER
i. Type: Gas analyzer on trolley for mobility
ii. 5 gas analyzer
iii. Automatic Pass/Fail judgement
iv . PC interface mandatory
v. Class Q .device compatible OIML R99 /0
6. PROCESS INDICATOR
i. Digital display /Color LCD
ii. On stand /wall clamping
iii. Additional screen
iv. Instruction on tes t procedures given to the inspector
are displayed on a digital display screen monitor.
7. SPEEDOMETER TESTER
i. Automated speedometer tester
11. Type: Roller speedometer tes ter
111. Sensor type: Digital speed sensor
iv. Frame: Heavy duty structural steel
v. Automatic pass/fail judgment
vi. Maximum tes t speed of 100 kph
vii. Maximum load per axle 500 kgs
viii. Lifting method: Hydraulic System/Pn eumatic
System
This lane applies to all private p assenger cars, utility vehicles, sports
utility vehicles, jeepneys and other types of veh icle with a gross
vehicle weight of 4,500 kgs . and below.
14
1. STAGE l.VEHICLE INFORMATION AND SPECIFICATION
INPUT/ ABOVE CARRIAGE & UNDER CARRIAGE INSPECTIONS
i. INSPECTION PROCEDURE:
The MVIT is required to log in through a finger scanning
device before every test.
a. Identity/ construction
b. Lighting system and reflectors
c. Windshield/window glass
d. Wiper/washer
15
e.
Chassis/ motor number authenticity
· f.
Horn
g.
Number plates
h.
Flqor board
i.
Body appearance
j. Seat belts
k. Door/Hinges
l. Rear view/ side mirror
m. Brake system/ parking brake
n. Clutch system
o. Steering
p. Driver's/passeni;;er's seat
q. Tires/wheels
r. Wheels bolts/nuts
s. Fuel tank/ fuel tank cap
t. Mobile Air-conditioning System (MAC'S)
u. EWD
v. Length, width and height (Rebuilt and locally
assembled)
vi. UNDER CARRIAGE ITEiylS FOR INSPECTION
a. Computer
b. Wireless touch screen monitor
c. Tablet for test operation control
d. Bar code scanner/ RFID reader
e. Axle Play Detector (Joint Play Tester)
f. Process indicator monitor
.!
g. IP Camera (2)
2. STAGE 2.
2.1 SIDESLIPTEST
a. Computer
b. Sideslip tester
c. Process indicator monitor
17
axle. It also measures the efficiency of th e shock absorbers
using the EUSAMA principle or its recognized equivalent.
i. INSPECTION PROCEDURE:
· a . Suspension Tester
b. Process indicator monitor
a. Comp·uter
b. Roller brake tester (with axle weighing device)
c. Process indicator monitor
i. INSPECTION PROCEDURE:
18
ii. TEST EQUIPMENT AND APPARATUS
a. Coi:nputer
b. Speedometer Tester
c. Process indicator monitor
3. STAGE 3.
i. INSPECTION PROCEDURE:
i.2.1 Computer
i.2.2 Headlight Tester
i.2.3 Process indicator monitor
i. l INSPECTION PROCEDURE:
The test procedure is for the determination of the
concentration of Carbon Monoxide (CO) and
Hydrocarbon (HC) emission from in-use motor
vehicles equipped with spark ignition engine
running a t idle speed. At this stage, the motor
vehicle gear- change control is in the neutral
positlon with the hand brake engage~ . The
temperature of the engine is at least 70°C. The
vehicle exhaust system is leak proof and will allow
the insertion of sampling probe by at least 30 . cm
from the tailpipe outlet.
While the engine idles , the . ins p ectors insert the
gas emission analyzer probe into the exhaust pipe
of the vehicle. This is operated automatically and
19
the measured data of the gas analyzer are
displayed. Results are transferred to database after
inspection is completed.
ii.2.1 Computer
ii.2.2 Opacity meter
ii.2.3 Process indicator monitor
20
3.3 SOUND LEVEL MEASUREMENT
i. INSPECTION PROCEDURE:
i. 1.1 Sonometer
i.1.2 Process indicator monitor
B. INSPECTION OF MOTORCYCLE
1. STAGE 1.
i. l Plate Number
i.2 File Number
i.3 Chassis Number
i.4 Motor Number
i.5 Make/Series
i. 6 Name of Owper /Operator
i.7 Address of Owner/ Operator
i.8 Type of Body/ Color
i. 9 Year Model
i.10 Gross Vehicle Weight
i.11 Net Capacity
i. 12 Fuel Type
i.13 Classification
i.14 Denomina tion
ii.1 Computer
ii.2 Wireless touch screen monitor
21
1·
i. l Handlebars
i.2 Spring
i.3 Lighting system and reflectors
i.4 Side mirror
i.5 Brake system
i.6 Clutch system
i. 7 Tires/ Wheels/ Balts/Nuts ·
i.8 Number plate
i. 9 Shock absorbers
i.10 Frame
i.11 Horn
i.12 Head stem bearings
i.13 Fuel tank cap
22
i. TEST EQUIPMENT AND APPARATUS
i.1 Computer
i'.2 Exhaust gas analyzer* (HC, CO, C02, NOx, 02)
i.3 Process Indicator monitor
*The test equipment shall be capable of testing
other types of fuel that will be introduced in the
market (e.g. CNG/ ethanol.)
i. INSPECTION PROCEDURE
ii. I Computer
ii.2 Headlight tester
ii.3 Process indicator
2. STAGE 2.
i. INSPECTION PROCEDURE:
ii. l Computer
23
...:
.·-
i. l Computer
i.2 Speedometer tester
i.3 Process indicator monitor
i. INSPECTION PROCEDURE:
ii . l Computer
ii.2 Sonometer
ii.3 Process indicator monitor
24
. .~
keyboard. The pass/fail judgment is indicated in every s tage of
I
inspection and displayed in an overhead TV monitor;
25
M. There shall be an · administrative office with clients' waiting lounge
with the provision for real-time broadcasting of the inspection
process as captured by Section 15 A-2;
0. There shall be a data c·ontrol room at the end of the inspection lane
for the releasing of Certificates of Inspection and for the database.
SECTION 15.0THERS
A. l. IP CAMERA
The PMVIC shall provide an IP camera for each stage of
inspectionfor monitoring and recording of the inspection
process.The LTO shall be able to monitor the actual activities of
inspection oniine/real-time.
2. HD Camera
An HD Camera (1080p) shall be dedicated to record the whole
process (preferably from an isometric point of view) to be shown
real-time to the Customer Lounge. The recording shall be
available for 1 year from the date of inspection.
26
C. PUBLIC ADDRESS SYSTEM
The PMVIC shall have a public addr ess system so that inspector
can communicate to the d river of a vehicle.
E. LANE CAPACITY
The inspection lane is capable of operating in accordance with the
performance standards and criteria set forth in these Guidelines.
F. TRAINING
All MVITs shall undergo training on the MVIC procedures and
processes. This willbe conducted by the LTO and certificates will
be issued upon training completion.
G. CALIBRATION
All specifications, brochures, and calibration process of all
inspection equipment shall be provided by the PMVICand
submitted to the Authorization Committee. All equipment sh.a ll
undergo calibration. every 6 months to ensure accuracy. The
calibration company shall be accredited by any government
agency such as Department of Trade and Industry (DTI).
I. SYSTEM RECOVERY
The PMVIC shall provide an operational system recovery plan;
indicate how service will be resumed, in case of power and
operational failure, and implement the same within one (1) day
from such failure.
M. AUTOMATIC PASS/FAIL.RESULTS
Passed or failed items shall be automatic and shall be transferred
to database after inspection process except those items under the
"visual inspection category".
N. AUTOMATIC ZEROING
To ensure data recording accuracy there shall be an automatic
resetting of data to zero before each test.
0. SECURE
The equipment must also prevent falsification of, or unauthorized
access to, test reports and data storage media. This shall be
accomplished by using an attached printer utilizing secure
certificates for compliance, at the end of the inspection line.
P. HARDWARE/SOFTWARE_ REQUIREMENTS
The PMVIC's system and service must be equipped with all
essential hardware and software needed to support the inspection
process. The PMVIC shall als o provide documentation of
programs, including user manuals, program descriptions, and the
name and address of any outside software m anufacturers.
Q. INTERNET CONNECTION
The PMVIC should have an internet speed of at least 5MBPS using
a leased line.
R. SECURITY
1. SECURITY
The system must have multiple levels of security (such
as biometrics fingerprint and AFIS) and access codes to
regulate system access and to ensure the protection of
information from unauthorized access (accidental or
intentional), modification, destruction, or disclosure .
The multiple levels of security should be relative to the
different types of users. It shall include:
28
J. Software security applications which can easily be
updated
n. Ability to document reports on various system and
user activities
iii. Number of layers/ divisions of security
iv. Length/description of passwords
v. Ability to restrict access for specified tasks
2. DATA SECURITY
The PMVIC database shall not be accessed/ open on-
site without prior notifications and approval by
LTO.Must ensure that all data collected or received by
the PMVIC becomes and remains the exclusive property
of the LTO. PMVIC.sshall not supply any report or
statistical information to any person or entity other
than the LTO without advance specific written
permiss_ion from the Authorization Committee.
3. INTERFACE SECURITY
The PMVlC's system. must support all LTO IT System
communications interface requirements as related to
access security.
29
SECTION 1 7. INSPECTION FEES
A. For every motor vehicle inspected in a PMVIC, the following fees shall
be collected:
1. Motor Vehicle
with GVW=< Php.l,800.00 Php. 900.00
4500 kg.
*Note: Re-Inspection fee is collected when a motor vehicle fails the first
inspection. Re-Inspection of the vehicle shall cover the stage where
it previously failed.
30
All m emoranda, circulars, or.ders and · other issuances in conflict or
inconsistent herewith are hereby superseded, amended and/ or repealed
accordingly.
SECTION 21.EFFECTIVITY
This Memorandum Circular shall talce effect fifteen (15) days following the
completion of its publication in the Offici'al Gazette a nd/ or in a newspaper
of general circulation and/ or the filing of th ree (3) copies with the UP Law
Center pursuant to Memorandum Circular 11 dated 09 October 1992 of the
·~ Office of the President.
!
"'
31
Annex. "A"
Lay Out of a Three (3) - Stage PMVIC Equipment for Light Duty Lane
Entrance
Stage 1
l
Computer
I
Stage 2
Computer
Sideslip Tester
Brake Tester
Suspension Tester
Speedometer Tester
.
Stage 3
Computer
l
Gas Analyzer
Opacimeter
....•·
Headlight Tester
So no meter
EXIT
32
Anne1,i: "B"
Lay Out of a Two (2) Stage PMVIC Equipment for Motorcycle Lane
ENTRANCE
Stage 1
Computer
Headlight Tester
Gas Analyzer
·i
!
Stage 2
Computer
Sonometer
Brake tester
Speedometer
·I EXIT
: ,,
33
'¢
p 1--~~~~~~~~~~~~~~~~~ 36 ~~~~~~~~~~~~~~~~~--l
6 6 I JO I s l - - -6 LV LANE
(')
-------f-+---f 1 ~·-
ODO 2. SUSPENSION TEST
3. BRAKE TEST
4. SPEEDOMETER TEST
STAGE 3
W3 FR I~
11•50 I
01 OFFICE
12.-so J
l. EMISSION TEST
2. SOUND LEVEL TEST
3. HEADLIGHT TEST
MC LANE
Ir={> i
I
STAGE 1
1. VISUAL INSPE:CTION
A, ABOVE CARRIAGE INSPECTION
I
i lllTII~II 1-.,---,-1I ~III
4114
2. EMISSION TE:ST
I
3, HEADLIGHT TEST
-r--r--111 I
I STAGE 2
I 1, BRAKE TEST
2, SPEEDOMETER TEST
r=t> PARKING 1
1
3, SOUND LEVEL TEST
I
/ 1111111111111 I
I
I
I
TYPICAL 2L V /2MC SITE
r={> I
J
1,500 SQ.M. AREA
'"'t~~~ _r
p
I.{)
C"')
x
~
c:
c:
~
~
36 LY LANE
6----j-I ·- STAGE
-6---1
1
10-- - - -1-
STAGE 2
1 - - -0
STAGE 3
i; STAGE 1
1. VISUAL INSPE:CTION
_E?il----1-L-o--I r1
.;' 7
A. ABOVE CARRIAGE INSPECTION
B. UNDER CARRIAGE I NSPECTION
STAGE 2
STAGE 3
u I
3. HEADLIGHT TEST
25
1~ OFFICE MC LANE
t - - - u.so - - - j -- -12.50 ' ,I STAGE 1
1. VI SUAL I NSPECT!ON
Lr- I
--- - - - - - ---------«J----- - - ,I i
I
A. ABOVE CARRI AGE INSPECTION
2. EMI SSION TEST
3. HEADLIGHT TEST
I STAGE 2
I
I
1. BRAKE TEST
p R I G I
i
I
I
I
2. SPEEDOMETER TES T
3. SOUND LEVEL TEST
I I
TYP ICAL 2 LV / 2MC SIT E
i~
ENTRANCE/EXIT
· ·- ··-- -~--
ANNEX "E"
LTO FormN o . - - - - -
Republic of the Philippines
Department of Transportation
LAND TRANSPORTATION OFFlCE
East Avenue, Quezon City
MVIC _ _ _ __ _ _
HC
MVIS Test Conducted By:
co
[
[
I Approved
I Disapproved
Chief-MVIC
MVIS REMAHKS
36
Department of Transportation ANNEX "F"
LAND TRANSPORTATION OFFICE
East Ave., Quezon City
DATE:-------
BUSINESS NAME:_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
.BUSINESS ADDRESS
0 Letter of Iritent;
0 Duly accomplished application form, under oath;
0 Location map and layout of the proposed PMVIC, including dimensions;
0 Bank Certiiicate of Deposit in the amount of not less than Pl0,000,000.00
or Letter of Credit or its equivalent;
·D Transfer Certiiicate of Title in the name of the applicant or Contract to
lease with a minimum lease_period of ten (10) years ;
0 Payment of Application Fee of Php. 50,000.00 which is non-refundable.
0 Profile of the applicant, joint venture partners, or incorporators with sworn
statement to organize and register as such once the Provisional Authority
is issued; and
0 Brief description of the MVIS equipment to be installed with
manufacturer's brochures, manuals and certificate of delivery schedule
from the manufacturer.
37
Certificate specifying the name of the authorized representative who must
be an officer of the cooperative;
D Certified True Copy of Mayor's or Business Permit;
0 BIR Registration and Tax Identification Number;
D Undertaking that the applicant shall comply with all labor laws;
D Proof of orders of the required inspection equipment.
D Building permit and copy of the building plan.
0 All source codes relative to _the PMVIC System, which are subject to LTO
testing/ evaluation, must only be compiled for installation to the PMVIC
upon approval. Failure of which shall mean automatic disapproval of the
application.
0 A sworn affidavit of the applicant that: the latter has no derogatory record
in government transactions;
D Shall comply with the list of personnel enumerated in the organizational
structure shall be available during the one-hundred fifty (150) days for the
construction of the PMVIS .facility; and that during the said period the
PMVIS facility shall be fully operational and;
D If applicable, Lease Contract with a minimum penod often (10) years
Doc No.
Page No. _ _
38
Department of Transportation
ANNEX "G"
LAND TRANSPORTATION OFFICE
East Ave., Quezon City
DATE:------
BUSINESS NAME:._ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ __
BUSINESS ADDRESS
Documentary Requirements:
Doc No.
Page No. _ _
39
ANNEX "H"
ui---1
CY
\-
w
~
D
(/)
i---1
t%
I
/~.
.
!
. ..t
I
40
ANNEX "I"
-
"'u:r
ITTO ·w.
I I w
D D
D
i' i' 8
i....
i....
w
8i....
D D I Cl
~ i....
Cl
' (\J
I' .I I ::3:
w
,__, ::3: ::3:
~~~
I
w w
I I I > ,__, ,__,
••
"'
I I I
a...
> >
2~
D w w
~
D·
I
D·
I
I- 0
V)
-
0
V)
~
r L~ :r
~
41