A Reference Guide To The Dell OptiPlex Diagnostic Indicators - Dell Vietnam
A Reference Guide To The Dell OptiPlex Diagnostic Indicators - Dell Vietnam
Remove all memory from PC, does the LED code change?
Memorysubsystem If it doesn't contact your technical support
ABCD MEM configuration activity or If it does add the memory modules back one at a time until
failure the fault re-occurs, test that module in another slot and
contact your technical support
https://www.dell.com/support/article/vn/en/vndhs1/sln284978/a-reference-guide-to-the-dell-optiplex-diagnostic-indicators?lang=en#Prior_to_2005 1/2
9/30/2019 A reference guide to the Dell OptiPlex Diagnostic Indicators | Dell Vietnam
Reset the BIOS and clear the NVRAM and any previous
errors
Remove all external peripherals
System resource If LEDs change, add parts back one at a time until fault re-
ABCD CFG
configuration occurs and contact your technical support
If the fault remains the same with parts removed, contact
your technical support
POST complete —
ABCD POV Onscreen error Troubleshoot as per the error message onscreen
message
POST complete — OS The Power On Self Test has passed all checks
ABCD STD Troubleshoot the HDD and the Operating System
hand-off complete