Technical data
General
Design Directional poppet valve
Actuation Solenoid
Size DIN NG6 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position Unrestricted
Ambient temperature [°C] -25...+50, observe permissible duty cycle
Weight [kg] 0,8
Hydraulic
Max. operating pressure P, A and T [bar] 350
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [mm²/s] 10...500 (10...500 cSt)
Viscosity recommended [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max. [l/min] 20 (at ∆p = 10 bar)
Static / Dynamic
Step response [ms] Energized: approx. 50
De-energized: approx. 60
Electrical characteristics
Duty ratio See diagram
Max. switching frequency [1/h] 2000
Protection class IP 65 in accordance with DIN 40050 (plugged and mounted)
Code K J U* G*
Supply voltage [V] 12 VDC 24 VDC 98 VDC 205 VDC
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 1.95 1.1 0.25 0.13
Power consumption [W] 23.4 26.4 24.3 26.6
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
* For a silicon bridge rectifier, set up apart from unit for connecting to a 50 or 60 Hz power supply, 110 V~(98=) or 230V~ (205V=).
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
D1SE.PMD RH
D 1 S E B W
Directional Size Seat Wet pin Spool Style Seals Solenoid Solenoid Design
control DIN NG06 valve armature voltage connection Series
valve CETOP 03 solenoid, without plug Not required
for ordering
NPPA D03 flanged
2 K
J
12V=
24V=
30
U* 98V=
G* 205V=
* For alternating current use
83 plug with rectifier.
Code Material
N NBR
V FPM
D1SE.PMD RH