Manual Book WP65l
Manual Book WP65l
C o m p r e s s o r
Type: WP 65L
Operator Manual
High-pressure Compressor
2-stage
Air-cooled
WP65L_BA1_Titel_en_1104.fm
WP65L_BA1_Titel_en_1104.fm
Note!
On this page only a few examples are shown. FurtherType Ap-
provals are available on request.
Genuine Sauer spare parts –
certified safety
M E N
CI
SPE Zertifikate_en_0.fm
Table of Content
1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.1 Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.2 Precautionary measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.3 Warranty and liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.4 Type approval and genuine Sauer spare parts . . . . . . . . . . . . . . . . . . . . . .10
1.5 J.P. SAUER & SOHN Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.6 Specific instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2.1 Conditions of Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2.2 Unauthorised modification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2.3 Safety Information - Warning and Caution . . . . . . . . . . . . . . . . . . . . . . . . . .15
2.4 Safety Warnings on the Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
2.5 Safety and protection devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
2.6 Noise protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
2.7 Waste disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
2.8 Safety requirements for personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
2.9 Personal protective equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
5
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
6.1 Safe operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
6.2 Operating modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
6.3 Initial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
6.4 Routine operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
8 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
8.1 J.P. SAUER & SOHN Maintenance Service . . . . . . . . . . . . . . . . . . . . . . . . .56
8.2 Maintenance safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
8.3 Maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
8.4 Table of tightening torques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
8.5 Checking screw connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
8.6 Changing the air filter insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
8.7 Change oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
8.8 Checking valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
8.9 Replacing valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
8.10 Replacing piston rings, gudgeon pins and gudgeon pin rings . . . . . . . . . . .67
8.11 Replacing the coupling flexible insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
8.12 Checking the condensate separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
8.13 Overhauling the drain valve (order-related) . . . . . . . . . . . . . . . . . . . . . . . . .74
8.14 Check safety valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
12 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
WP65L_BA_en_1104_IVZ.fm
6
WP65L_BA_en_1104_IVZ.fm
7
1 General information
1.1 Foreword
This Operator Manual provides installation guidance, safe
operation, maintenance and repair instructions with illustrated
parts list.
The following unique specification for the Sauer compressor can
be found on the nameplate affixed to the compressor:
– Compressor type
– Works number
– Year of construction
8
General information
9
1.4 Type approval and genuine Sauer spare parts
• Type approval for the Sauer compressor is valid under the
condition that parts and components specified and qualified by
J.P. SAUER & SOHN are used. Type approval is provided by
the Classification Society and the EC Declaration of
Conformity or EC Manufacturer's Declaration. Failure to
observe these requirements may void type approval.
• Only the use of genuine Sauer spare parts will ensure
compliance with these specifications and, therefore, reliable
and safe operation of the Sauer compressor.
• If non-genuine Sauer spare parts are used, we reserve the
right of exclusion from liability for personal injury and
equipment damage.
• Genuine Sauer spare parts are supplied with a Certificate of
Conformity and a Certificate of Authenticity. An example of this
document is shown just before the Table of Contents in these
instructions. If spare parts are delivered to you without this
certificate, there is a risk that these are not genuine Sauer
spare parts. In such an instance please contact our Customer
Service.
Note!
This is a high-pressure compressor. For your own safety and for
reliable compressor operation, use genuine Sauer parts only.
Correct Incorrect
Only use genuine Sauer spare parts Do not use parts from the
supplied with a certificate! “grey market”!
WP65L_BA1_en_1104.fm
10
General information
Phone (international):
Technical information +49 431 39 40 -87
Spare parts orders +49 431 39 40 -86/886
Fax (international): +49 431 39 40 -89
Emergency service
(international): +49 172 4 14 63 94
E-mail: [email protected]
Web: www.sauercompressors.com
Note!
If you have questions regarding your Sauer compressor, please
specify the compressor model and serial number (see Chapter
11 or nameplate on the compressor).
WP65L_BA1_en_1104.fm
11
1.6 Specific instructions
Lists General lists are marked using a dash.
Example:
The compressor cooling system consists of
– Fan wheel
– Fan wheel housing and
– Cooler assembly
Safety Safety and warning instructions are presented using icons with
instructions clear instructions. The safety instructions are described in detail
in Chapter 2.
WP65L_BA1_en_1104.fm
12
WP65L_BA1_en_1104.fm
General information
13
2 Safety
2.1 Conditions of Use
This compressor system must only be used for the compression
of the specified gas/media (see factory test). The Sauer
compressor must not be used at ambient temperatures below
+5 °C or over +55 °C. Any other unauthorised use requires the
express written approval of J.P. SAUER & SOHN.
In addition, specified conditions of use also include observing the
Operator Manual and the installation requirements and
maintenance intervals described there.
Most accidents which occur during operation and maintenance of
machinery result from failure to observe basic safety rules or
precautions.
When handling, operating or carrying out maintenance,
personnel must observe safe engineering working practices and
local regulations.
14
Safety
Warning - Danger!
High risk.
Ignoring these safety instructions can cause personal injury, or
death, and significant equipment damage.
Caution - Note!
Lower risk.
Disregarding this safety note may result in damage to the
equipment.
WP65L_BA1_en_1104.fm
15
2.4 Safety Warnings on the Machine
Danger!
Safety labelling affixed to the machine must not be altered or
removed. Replace damaged or lost safety labels immediately
with an exact replica.
16
Safety
Danger!
Safety devices must not be adjusted, tampered with or removed.
The safety devices must be periodically tested and checked:
Safety valves must only be
– installed with a lock-seal and
– replaced, adjusted and re-sealed by authorised personnel.
Temperature The Sauer compressor is equipped with a safety fuse in the final
monitoring separator to protect the unit in case the compressor cooling fails.
The safety fuse melts at 121 °C and releases an exhaust port for
the compressed air if the temperature limit is exceeded.
As an alternative to the safety fuse, the Sauer compressor can be
equipped with a high air temperature switch or a sensor which
replaces the safety fuse. The high air temperature switch or
sensor sends a signal to the control which switches off the
compressor if the temperature of the compressed air exceeds the
limit value.
Oil monitoring Optionally, an oil level switch can be installed which sends a
signal to the compressor control if the oil level is too low and
stops the compressor.
Final pressure A final pressure switch is included with the Sauer compressor
monitoring which is installed by the operator depending on the operation
task. The final pressure switch triggers as soon as the adjusted
values are reached and sends a signal to the control which starts
or stops the compressor.
Optionally, a sensor can also be installed as well.
WP65L_BA1_en_1104.fm
17
2.6 Noise protection
Sound pressure level details are found in the Technical
Specification (see Chapter 4).
The compressor can be equipped with a sound-dampening
enclosure, available as an accessory from
J.P. SAUER & SOHN.
Danger!
With a free field of 1m the sound pressure level is greater than
85dB(A) if the compressor is operated without sound-
dampening enclosure. Consequently, each person must wear
hearing protection when working in the same room where the
compressor is operated.
Note!
A corresponding mandatory sign is affixed to the compressor
(see Chapter 2nd4).
Note!
The operator must affix an additional corresponding mandatory
sign in a clearly visible manner near the machine or at the
entrance door.
Note!
The following materials which accumulate during operation of
the compressor must be disposed of in an environmentally
sound manner in accordance with applicable laws:
– Condensate (oil/water) arising from inter-cooling in the
compression process
– Used oil and grease, and rags soiled by oil and grease
– Cleaning agents and rags soiled by such agents
WP65L_BA1_en_1104.fm
18
Safety
– Hearing protection
– Safety boots
– Protective goggles
– Protective gloves
19
3 Design and function
3.1 Overview
Note!
Details of parts and spare parts can be found in the spare parts
catalogue.
3 1 4 2 7 5 11
10 6 8 9
WP65L_BA1_en_1104.fm
20
Design and function
Item Designation
1 Cylinder 1st stage
2 Cylinder 2nd stage
3 Cooler
4 Safety valve 1st stage
5 Safety valve 2nd stage
6 Condensate separator 1st stage
7 Condensate separator 2nd stage
8 Drain valve 1st stage
9 Drain valve 2nd stage
10 Oil dipstick
11 Electric motor
WP65L_BA1_en_1104.fm
21
Vertical
sectional view 3 2 1 7
10
4 5 9
Item Designation
1 Cooler 1st stage
2 Cooler 2nd stage
3 Fan wheel
4 Connecting rod 1st stage
5 Connecting rod 2nd stage
6 Flexible coupling
7 Flywheel
8 Bell housing
9 Crankshaft
WP65L_BA1_en_1104.fm
10 Bearing housing
22
Design and function
Cross
section view
1 4
2
5
3 6
8 7
Item Designation
1 Cylinder with head and valve 1st stage
2 Piston 1st stage
3 Connecting rod 1st stage
4 Cylinder with head and valve 2nd stage
5 Piston 2nd stage
6 Connecting rod 2nd stage
7 Crankcase
8 Lubricating pin
WP65L_BA1_en_1104.fm
23
3.2 Functional description
Drive The Sauer compressor is driven by an electric motor which is
screw-connected to the clutch housing. The torque is transmitted
by means of a flexible coupling.
As an alternative, a diesel motor can be used which is then
installed via a special flange. The torque is transmitted by means
of a centrifugal clutch.
Compression The compressor takes in the ambient air via a layered filter with
a tube silencer and compresses it in two compression stages with
a total of two single-stage cylinders to the final pressure. Each
cylinder is a compression stage, after which the air is inter-
cooled.
The compression temperatures are below the flash point of
standard mineral-based motor oils.
The cylinders arranged in a V-configuration are equipped with
valves which are easy to maintain and have a long service life.
Due to the low compression temperatures, there is virtually no
coking on the valves.
Cooling An axial fan mounted on the crankshaft sucks cooling air from
ambient air and blows it across the cylinders, coolers, valves and
oil pan. An optimal cooling of each compressor component is
achieved due to the placement of the fan.
24
Design and function
Oil/water Condensate is drained via drain lines. For each separator there
draining and are solenoid valves installed in the drain lines. The drain valves
must be open when the Sauer compressor is shut down. A few
pressure relief
seconds after starting, the drain valves should close and the
compressor should power up against system pressure. The drain
valves should drain the system during operation at preset
intervals. The control of the drain valves is carried out by the
compressor control.
Lubrication The crankshaft bearing and piston are lubricated by oil splash in
the crankcase. The lubricating pin located at the connecting rod
of the 1st stage dips into the oil at the bottom of the crankcase and
flings the oil against the lubricating points. Optionally, the oil level
can be monitored using an oil level monitoring device. The
compressor is stopped by the control if there is not enough oil.
WP65L_BA1_en_1104.fm
25
3.3 Displays on the Sauer compressor
1 2
Pressure gauge 2nd stage Final pressure of the compressed air after the
2
2nd stage
WP65L_BA1_en_1104.fm
26
Design and function
Note!
If the compressor control is supplied by J.P. SAUER & SOHN,
read the documentation supplied.
Display/operating
Explanation
element
Signal lamp Illuminates when the compressor is running.
“Operation”
Fault indicator lamp Illuminates if the compressor has shut down because of excess
“Overcurrent” motor current.
Mode Indicates the hours the compressor has run.
time counter
Mode • “Manual” mode:
selector switch Starts the compressor manually. The compressor starts up and continues to
run until it is manually turned off again.
• Selector position “0”:
Turns the compressor off manually. Any pending fault messages are reset.
• “Auto” mode:
The compressor starts and stops with the opening and closing of a remote
contact (e.g. pressure switch at a compressed air vessel).
Main switch Disconnects the power supply from the compressor control to the
compressor.
A main isolator switch should be installed if required by local law
and regulations.
Optional:
Fault indicator lamp Illuminates if the compressor has shut down because of excess
"Air temperature" compressed air temperature.
Fault indicator lamp Illuminates if the compressor has shut down because the oil level
"Oil level" is too low.
WP65L_BA1_en_1104.fm
27
4 Technical Specification
4.1 Specification data
Designation Data
Compressor type WP 65 L
Number of cylinders 2
Number of compression stages 2
Piston stroke 66 mm
Maximum speed 1800 rpm
Direction of rotation (when looking toward Clockwise
flywheel)
Drain valve:
Pickup and holding power 18 VA/14 W (order-specific)
WP65L_BA1_en_1104.fm
28
Technical Specification
Designation Data
Note!
Please refer to the order-specific documentation of your
compressor for data such as final pressure, speed, power
requirements, etc.
WP65L_BA1_en_1104.fm
29
4.2 P&I Flow Diagram
1 2 4 3 5 9
M 1 2 11 7 14 15 16
17 18 6 19 12 8 10 20 13
WP65L_BA1_en_1104.fm
30
Technical Specification
Item Designation
1 Electric motor
2 1st compression stage
3 2nd compression stage
4 Cooler 1st stage
5 Cooler 2nd stage
6 Condensate separator 1st stage
7 Condensate separator 2nd stage
8 Pressure gauge 1st stage
9 Pressure gauge 2nd stage
10 Safety valve 1st stage
11 Safety valve 2nd stage
12 Solenoid valve (drainage) 1st stage
13 Solenoid valve (drainage) 2nd stage
14 High-pressure hose
15 Non-return valve
16 Compressed air outlet
17 Suction filter
18 Air intake
19 Condensate outlet 1st stage
20 Condensate outlet 2nd stage
WP65L_BA1_en_1104.fm
31
5 Transport and Installation
5.1 Transport
Shipping The machine is packed ready for shipping.
• The Sauer compressor must be checked for completeness
and any damage immediately upon receipt.
• Damage to the packaging or the machine must be reported to
the transport firm and J.P. SAUER & SOHN immediately.
Danger!
Suspended load during transport.
The forklift truck/crane must have sufficient load-bearing
capacity.
• Ensure that no personnel are within the danger area of the
suspended load and the forklift truck/crane.
• Sling the unpacked compressor onto the lifting eye bolt (1)
(see illustration).
• Raise, move into position and set down with care.
1 WP65L_BA1_en_1104.fm
32
Transport and Installation
Note!
The standard factory protective packing is sufficient for a
maximum storage period of 12 months.
Note!
High-pressure hoses can be stored for up to five years after
delivery.
WP65L_BA1_en_1104.fm
33
5.3 Installation
Note!
If in doubt regarding the suitability of the intended installation
area, please contact J.P. SAUER & SOHN. If required for the
installation area, Sauer can provide help with the design of a
ventilation system.
Installation – The installation area must be dry and free from dust.
requirements – Ensure that the installation is ventilated in such a way that the
heat generated during operation is removed.
– Room temperature during operation of the Sauer compressor:
max. 55 °C +5 °C … +55 °C
(Please contact J.P. SAUER & SOHNfor operation outside
this temperature range).
min. 5 °C
Note!
The air temperature at the cooling air inlet of the compressor
must not exceed +55 during operation. Conditions in the area of
installation as well as the heat generated by the compressor and
any other machines installed in the same area must be kept in
mind.
• If necessary, install a ventilation or air extraction system in the
area.
• Install the fresh air feed in such a way that the cooling air
stream is never directed at the compressor. Otherwise, there
is a danger that condensation will occur within the machine,
with corresponding consequential damage.
WP65L_BA1_en_1104.fm
34
Transport and Installation
Correct Incorrect
Note!
J.P. SAUER & SOHN would be pleased to advise you on
installation of the compressors.
WP65L_BA1_en_1104.fm
35
Foundation
Note!
The standard delivery anti-vibration resilient mount has a
resonant frequency of approx. 10 Hz.
Excitation of the compressor foundation by vibrations from other
machines installed in the vicinity must not be in the 10 Hz range.
Otherwise there is a danger that the standard anti-vibration
resilient mount could be destroyed by resonating vibration.
WP65L_BA1_en_1104.fm
36
Transport and Installation
Note!
The oil filler tube is protected with an insulating hose. The
insulation material (1) must not be removed.
Pipelines The compressed air outlet (2) and drainage connections (3) of
the Sauer compressor must be connected by hose connections
(4) to any of the system owner’s permanent piping.
1 2
Danger!
At the compressor start-up and during drainage compressed air
escapes from the drainage connections. Consequently, do not
operate the compressor without hose lines connected.
WP65L_BA1_en_1104.fm
37
Hose lines The hose lines must be installed free of tension and not twisted.
Correct Incorrect
Drainage system
Note!
Accumulated condensate contains oil. It may only be disposed
of in compliance with applicable legal regulations.
J.P. SAUER & SOHN offers condensate processing systems for
separating oil from condensate.
Note!
We recommend connecting up the compressor drainage
separately.
If you wish to combine the drainage of several compressors,
please observe the following:
– Choose a sufficient nominal diameter for the common drain
line;
– Connect the drain lines of the individual compressors at a
sharp angle to the common drain line, so that no pressure can
build up in the drain line of a compressor that is not in
operation. WP65L_BA1_en_1104.fm
38
Transport and Installation
39
Connections The illustration below shows the connections and the fittings for
the operation of a typical Sauer compressor.
1 2 6
5 4 3
Note!
For technical specifications of the individual items, please refer
WP65L_BA1_en_1104.fm
40
Transport and Installation
Note!
The final pressure switch must be connected directly at the
compressed air vessel to ensure smooth, even compressor
operation.
41
5.6 Filling with oil
Note!
Unless otherwise ordered, Sauer compressors are delivered
without oil filling.
Danger!
Make sure to fill the crankcase of the compressor with oil before
initial operation!
Only use lubricating oil approved by J.P. SAUER & SOHN (see
Chapter 10).
Note the amount of oil needed (see Chapter 4).
1 2
3
4
Note!
Only fill with oil up to the upper mark on the oil level indicator.
Overfilling increases the oil consumption of the compressor.
WP65L_BA1_en_1104.fm
4. Replace the dipstick and screw the oil fill cap back in.
42
Transport and Installation
43
6 Operation
6.1 Safe operation
Danger!
Only authorised persons are permitted to put the Sauer
compressor into operation and operate it!
Danger!
Only switch on and start the compressor when
– it has been checked that it is in perfect condition;
– all tools and foreign objects have been removed from the
machine.
Danger!
Immediately turn compressor off if personnel and property are
endangered. Only re-start compressor when there is no more
danger or possible damage.
Danger!
In Automatic mode the compressor starts automatically without
warning.
Danger!
Risk of burns from touching hot surfaces of the compressor
during operation. Wear protective gloves.
Danger!
Risk of hearing damage because of the sound pressure level
while the compressor is running! Wear hearing protection.
Note!
Switch compressor off in the event of any abnormal/fault
conditions or unexpected events. Eliminate the cause of
problem with the help of Chapter 7.
WP65L_BA1_en_1104.fm
44
Operation
When the Sauer compressor starts, it starts without load with the
drain valves open. After a few seconds the valves close and the
compressor powers up against system pressure.
A compressor control - whether provided by Sauer or the
customer - must always be equipped with this function.
WP65L_BA1_en_1104.fm
45
6.3 Initial operation
Check the Allow the Sauer compressor to run only for a few seconds to
direction of check the direction of rotation.
rotation 1. Switch the power supply on.
2. Set the mode selector switch to “Manual” to start the
compressor in manual mode.
3. Immediately check the compressor’s direction of rotation. It
must rotate in the direction indicated by the arrow on the
crankcase.
4. Set the mode selector switch to “0” to stop the compressor.
5. Switch off the power supply.
6. If the direction of rotation is incorrect, the polarity of the
electric motor should be changed by a qualified electrician.
46
Operation
Note!
Compressors may be started no more than five to six times
within one hour.
The minimum period of operation must be 10 minutes per start.
Repeatedly using the system for shorter operating periods leads
to reduced gas quality and/or damage to the compressor.
WP65L_BA1_en_1104.fm
47
Stage pressure diagram 1st and 2nd stage
40
30
20
10
0
1 2 3 4 5 6
1st stage [bar]
Note!
Depending on the desired final pressure in the 2nd stage, the
allowable pressure for the 1st stage can be read from the above
diagram.
WP65L_BA1_en_1104.fm
48
WP65L_BA1_en_1104.fm
49
Operation
7 Troubleshooting guide
Note!
• Should a malfunction occur, first check the indicators on the
compressor control panel and on the compressor.
• Try to correct the fault with the help of the table below.
If the fault cannot be corrected, please contact
J.P. SAUER & SOHNCustomer Service. The fault description
journal is in the Appendix of this Operator Manual.
Danger!
Risk of injury from pressurised components! Prior to work on the
components, the compressor must be depressurised.
Risk of injury due to electrical voltage!
Prior to work on the components, the compressor must be de-
energised.
50
Troubleshooting guide
51
Fault Probable cause Remedy
Pressure gauge of the Valve of the 2nd stage is Check the valve of the 2nd stage
1st stage is showing leaking. and replace if necessary.
excessive pressure.
The pressure gauges Valve of the 1st stage is Check the valve of the 1st stage
of all stages show leaking. and replace if necessary.
insufficient pressure.
Air filter very dirty. Clean the air filter insert or
replace it.
The pressure gauges No power at the drain Check drain valve power supply.
of all stages show no valve.
pressure.
Drain valve is faulty. Check the drain valve and
replace it if necessary.
Air escaping from the Connection gaskets or Replace faulty gasket or seal.
compressed air lines. seals leaking.
Cutting rings leaking. Switch compressor off. Wait until
all parts are no longer under
pressure; check the pressure
gauge for this. Tighten all
fittings.
Air escaping from the Compressed air Replace fan.
overflow opening of the temperature at the outlet Replace safety fuse.
final separator's safety too high; insufficient
fuse. cooling due to faulty fan.
Compressed air Clean cooler.
temperature at the outlet Check ventilation.
too high; Replace safety fuse.
Cooler very dirty;
insufficient ventilation.
Compressor was Compressed air Check whether fan wheel can be
switched off, high air temperature at the outlet turned, check fan wheel and
temperature monitoring too high; insufficient replace if necessary. Check if
(option) has tripped. cooling due to faulty fan. the ambient temperature is
<+55 °C. Check that the cooling
air inlet is not blocked.
Cooler dirty or supply line Clean cooler. Check room
blocked; insufficient ventilation.
ventilation.
WP65L_BA1_en_1104.fm
52
Troubleshooting guide
53
Fault Probable cause Remedy
Water in oil Incorrect ventilation Change room ventilation.
(excessive cooling of
compressor).
Poor drainage. Check drain lines and drainage
intervals.
Insulation tube at the Replace insulation tube.
crankcase vent is
missing or damaged.
Very short compressor Extend compressor running
running time. time.
Premature fracture of Poor drainage. Check and optimise drain lines
valve plates, valve and drainage intervals. Replace
springs, or valve reeds. valve.
WP65L_BA1_en_1104.fm
54
WP65L_BA1_en_1104.fm
Troubleshooting guide
55
8 Maintenance
8.1 J.P. SAUER & SOHN Maintenance Service
Phone (international):
Technical information +49 431 39 40 -87
Spare parts orders +49 431 39 40 -86/886
Fax (international): +49 431 39 40 -89
Emergency service
(international): +49 172 4 14 63 94
E-mail: [email protected]
Web: www.sauercompressors.com
56
Maintenance
Danger!
Risk of injury due to improper operation!
Only authorised persons are permitted to service and make
adjustments to the Sauer compressor!
Danger!
Risk of injury from hot surfaces!
Allow compressor to cool down after shutting OFF.
Danger!
Risk of injury from pressurised compressor components!
Check the pressure gauges before servicing to ensure the
compressor is completely relieved of pressure.
Danger!
High voltage! Danger to life!
– Never assume that a circuit is de-energised – Always check
for your own safety!
– The main switch is energised, even when it is turned off.
– Components being worked on must only be energised if this
is explicitly specified.
Danger!
Danger of death from missing protective equipment and missing
guards!
Reinstall all protective equipment and guards after servicing.
This also applies to electrical protection devices (e.g. earth
wires).
WP65L_BA1_en_1104.fm
57
8.3 Maintenance schedule
Danger!
For all maintenance work Chapter 8.4 for the tightening torques
of the designated screws and nuts must be observed.
Note!
The maintenance intervals specified in the maintenance
schedule must be adhered to. Shortening maintenance intervals
is of no advantage with regard to operating performance or
service life of the Sauer compressor.
Note!
After the last maintenance stage the maintenance schedule
begins all over again.
Note!
J.P. SAUER & SOHN recommends to have an inspection
(function test) carried out by qualified personnel at least once a
year.
58
Maintenance
Interval
f < 1,000 h
50 h after
1,000 h
2 000 h
3 000 h
4 000 h
Maintenance work
069 146
069 147
069 146
069 148
Maintenance kit part number
Operating hours
Date
Signature (initials)
59
Note!
Carry out a check 50 h after completing a maintenance
routine. Check all screws affected by maintenance to see if they
are tight.
60
Maintenance
1 2
4 3
1. Open the fasteners (1) and remove the air filter cover (2).
2. Remove used air filter insert (3).
3. Clean housing (4) using a suitable solvent and wipe out with
a lint-free rag.
4. Insert new air filter insert.
5. Insert cover and close fasteners.
WP65L_BA1_en_1104.fm
61
8.7 Change oil
Note!
Use oil according to lubricant table (see Chapter 10) or
according to oil recommendation for Sauer compressors.
1
2
4
5
62
Maintenance
– Damage
– Oiling
– Coking
– Corrosion and
– Humidity
Note!
If there is heavy coking or damage, replace the complete valves.
Determine the cause (see Chapter 7).
Note!
Install all valves with new gaskets and washers. Do not reuse old
gaskets and washers.
Only use genuine Sauer spare parts.
Installation of old or other gaskets and washers may lead to
leakage and may cause substantial damage to the compressor.
WP65L_BA1_en_1104.fm
63
Installing the
1st stage valve
2
4
1
3
7. Place new cylinder head gasket (3) within the stud bolts onto
the cylinder (5). Insert the new low-tolerance gasket ring (4)
into the groove of the valve (1) Now insert the valve (1) into
the cylinder head (2) from below.
(Caution: The low-tolerance gasket ring may not shift while
doing so).
8. Hold the cylinder head and valve. Now carefully slide both
parts together over the stud bolts and place them onto the
cylinder head gasket.
9. Tighten the cylinder head nuts by hand.
WP65L_BA1_en_1104.fm
64
Maintenance
Installing the
2nd stage valve
1 2
5 4 3
10. Insert new O-ring (3) into the groove between cylinder (5) and
valve (4). Insert new cylinder head gasket (2) between valve
(4) and cylinder head (1).
11. Tighten the cylinder head nuts by hand.
12. Screw pipe fittings and hose line onto the cylinder heads and
tighten by hand.
13. Securely tighten the cylinder head nuts. Observe the
tightening torque (see Chapter 8.4).
14. Securely tighten pipe fittings and hose line.
WP65L_BA1_en_1104.fm
65
8.9 Replacing valves
Remove and install valves as described in Chapter 8.8. Make
sure to completely replace the valves when doing this.
Note!
Valves which have reached their service life must be replaced
and disposed of.
J.P. SAUER & SOHN do not recommend repairing used valves
due to material fatigue.
WP65L_BA1_en_1104.fm
66
Maintenance
Note!
If the piston is not held while the cylinder is being pulled off, it will
strike the crankcase.
3. Remove the gudgeon pin circlips, push out the gudgeon pin
and remove the piston.
4. Remove all piston rings from the respective pistons and clean
the pistons.
Note!
Always replace all piston rings by new ones.
Checking 5. Check cylinders and pistons for scoring marks and excessive
pistons and wear. Replace parts as required.
cylinders
Note!
If edges can be felt on the piston running surface in the cylinder,
these edges must be broken using a Flexhon brush or a Scotch-
Brite abrasive pad. As otherwise the edges may damage the
new piston rings when installing the piston.
WP65L_BA1_en_1104.fm
67
Measuring
piston wear
2 1
Note!
It is possible to measure used and new piston rings.
1st measurement:
Insert the piston ring into the cylinder approx. 5 mm (1) beneath
the upper edge (above the turning point of the top piston ring) and
measure the gap clearance using a feeler gauge in the area (3)
where the piston rings are not running.
2nd measurement:
Slide the piston ring down by approx. 50 mm (2) (beneath the
turning point of the lowest piston ring) and measure the gap
clearance in the wear area (4) again.
WP65L_BA1_en_1104.fm
68
Maintenance
Note!
J. P. Sauer und Sohn's Customer Service is to be consulted if the
difference between the two gap clearances is greater than
indicated in the table above.
WP65L_BA1_en_1104.fm
69
Replacing the 1. Press gudgeon pin bearing into the connecting rod's small
gudgeon pins/ end with a suitable tool and replace it by a new gudgeon pin
bearing.
gudgeon pin
2. Install the pistons to the connecting rods. To do this, press the
bearings (small-
new gudgeon pin in and insert the circlips.
end bearing)
Note!
Check circlips for secure fit in the grooves.
Installing piston 3. Install piston rings in the respective piston. Make sure they
rings are in the correct position: piston rings having an asymmetric
cross section are marked with “TOP” on one of the surfaces.
The marked face must be at the top when the piston ring is
installed (see illustration).
1 2
TOP
TOP
TOP
TOP
Item Designation
1 Piston 1st stage
2 Piston 2nd stage
circumference.
70
Maintenance
71
8.11 Replacing the coupling flexible insert
Note!
Applies to Sauer compressors with electric motor.
1 2 3 4
7. Carefully slide the electric motor (3) onto the compressor (1)
and tighten the fixing screws (2).
8. Remove the support under the bell housing.
9. Reinstall the disconnected connecting lines and pipes.
WP65L_BA1_en_1104.fm
72
Maintenance
1 2
Item Designation
1 Separator 1st stage
2 Separator 2nd stage
73
8.13 Overhauling the drain valve (order-related)
1
2
6 4
7
10
8
74
Maintenance
Note!
The coil and the armature must always be dry.
75
8.14 Check safety valves
Danger!
Dirt particles may be flung out by the escaping air.
Wear protective glasses and gloves!
Keep your head away from the safety valve.
Danger!
High buildup of noise during blowing off.
Wear hearing protection!
Danger!
Safety valve may reach high temperatures due to operation.
Wear protective gloves!
Note!
Depending on the installation location of the compressor, the
operator of the compressor system must determine the
maintenance intervals in compliance with the valid, country-
specific regulations, standards and laws.
Note!
The safety valves may only be checked by personnel especially
trained for this purpose.
Note!
The J.P. SAUER & SOHN Customer Service offers proper
safety valve inspections within the framework of inspection
agreements.
Please contact our Customer Service.
WP65L_BA1_en_1104.fm
76
Maintenance
2 1
The actual design of safety valve may differ from the illustration.
2. Turn the lifting device (1) on the safety valve (2) to the left until
the safety valve blows.
3. After the safety valve (2) actuates, turn the lifting device (1)
back to the right as far as possible. The valve must close
tightly after doing this.
Note!
The pressure setting must only be changed at the
manufacturer's factory. The safety valve is sealed.
Danger!
The safety valve is a part of the safety device.
Safety devices must not be adjusted, tampered with or removed.
The safety devices must be periodically tested and checked:
WP65L_BA1_en_1104.fm
77
9 Storage, Preservation – “Lay-up”
procedure
9.1 Safety when storing and removing
Danger!
The compressor is only to decommissioned and disassembled
by the owner's trained specialists. These specialists must be
familiar with the protection devices and regulations before
starting the work. Any work on the electrical installation must be
carried out by qualified electricians only.
In addition, information contained in suppliers’ documentation
must be observed.
WP65L_BA1_en_1104.fm
78
Storage, Preservation – “Lay-up” procedure
Note!
Use one of the preservation oils recommended in Chapter 10 for
corrosion protection.
The preservation oil has satisfactory running properties. In an
emergency the machine can be started for a short duration when
filled with preservation oil.
Note!
The preservation is sufficient for 12 months. After expiry of this
period the compressor must be preserved again.
79
1 4
6. Remove air filter (1) on the cylinder head of the 1st stage (2)
by loosening the clamp (3) and removing the air filter (1).
5 6
7. Unscrew the 1st stage safety valve (5) on the 2nd stage (6)
cylinder head.
8. Slowly inject about 1 to 15 cm3 of preservation oil into the
intake fittings (4) of the 1st stage.
9. Slowly inject about 10 cm3 of preservation oil into the 2nd
stage (6) cylinder head opening (7).
WP65L_BA1_en_1104.fm
10. Reinstall air filter and safety valve. Use a new gasket for the
safety valve.
80
Storage, Preservation – “Lay-up” procedure
81
9.3 Disassembly
Follow these 1. Turn compressor off and disconnect it from power supply.
steps for 2. Read the pressure gauge to ensure that the compressor is
disassembly: completely depressurised.
3. Remove oil and lubricants and dispose of in an
environmentally safe manner.
4. Drain any remaining condensate and dispose of in an
environmentally safe manner.
Disposal
WP65L_BA1_en_1104.fm
82
WP65L_BA1_en_1104.fm
Storage, Preservation – “Lay-up” procedure
83
10 Lubricant table
Scope The lubricant table applies to all Sauer compressors which are
designed to compress air.
The lubricant table does not apply to
– For Sauer compressors designed to compress neutral gasses
– for temperatures outside the 5 °C ... 55 °C range.
Note!
The recommended types of oil reduce the level of coking in the
compressor valves and the upstream pipe lines and fittings to a
minimum.
Lubricants which are not listed in the lubricant table may only be
used after approval has been given by J.P. SAUER & SOHN.
Otherwise the guarantee is made void.
Please contact our Customer Service when selecting oils not
listed, or if operating conditions differ from those recommended.
Note!
Unless otherwise ordered, Sauer compressors are delivered
without oil filling.
WP65L_BA1_en_1104.fm
84
Lubricant table
85
Brand Product name Group
NATO classified O - 278 VDL-120
NATO classified OMD 113 VDL-100
Note!
The product name may vary by country.
Note!
Further oils for various applications for Sauer compressors can
be found in the "Oil recommendations for Sauer compressors"
document.
WP65L_BA1_en_1104.fm
86
WP65L_BA1_en_1104.fm
87
Lubricant table
11 Spare Parts and Accessories
Note!
Please note the information in Chapter 1 regarding our genuine
Sauer spare parts.
J.P. SAUER & SOHN guarantee the complete spare parts supply
over the entire service life of the Sauer compressor.
Our genuine Sauer spare parts are subject to constant quality
control and further development. They conform to the latest
technical developments.
In addition to genuine Sauer spare parts, our range of supply
includes many accessories for your Sauer compressor as well as
special equipment for your entire compressed air system,
including:
88
Spare Parts and Accessories
Spare parts The spare parts catalogue is in the Appendix to this Operator
catalogue Manual.
Compressor type:
Works number:
Year of construction:
89
12 Appendix
This Appendix to the Operator Manual contains:
WP65L_BA1_en_1104.fm
90
Appendix
J.P. SAUER & SOHN
Commissioning certificate for compressors Maschinenbau GmbH
Brauner Berg 15 - 24159 Kiel
Phone: +49 - 431- 39 40 - 0
Fax: +49 - 431- 39 40 - 89
E-mail: [email protected]
Purchaser Operator Installation site
Company Company
Street Street
Postcode Postcode
Contact Contact
Phone number Phone number
Customer number
Order number
Compressor type Serial No.
Delivery date Operating hours
Date commissioned
Sauer service engineer Company/name
Company/name
Company/name
Company/name
Installation of compressor/complete system Check of rotational
direction
Good Faults Compression °C
temperature
Ventilation Suction temperature °C
Good Faults Start/stop pressure
Ambient conditions Oil level check
Good Faults Control system check
Voltage? Test run
Good Faults
Vibration behaviour of compressor
Good Faults
Accessories Installation of complete system carried out by:
Compressed air vessel
Refrigerant type dryer
Adsorption dryer Good Faults
Filter
Condensate removal
Operating personnel have received instruction and are familiar with the safety and maintenance requirements.
The maintenance instructions are available to the operator.
The operating company has been advised to use only genuine SAUER & SOHN spare parts.
Notes/faults:
WP65L_BA1_en_1104.fm
91
J.P. SAUER & SOHN
Return of goods Maschinenbau GmbH
Notification of claim Brauner Berg 15 - 24159 Kiel, Germany
Phone: +49 - 431- 39 40 - 0
Date: Fax: +49 - 431- 39 40 - 89
E-mail: [email protected]
Manufacturer: Please always complete.
Company Compressor type:
Street
Postcode/City
Customer No. Serial No.:
Location
End customer: Operating hours:
Company
Street Date of fault:
Postcode/City
Customer No. Ambient temperature:
Location
Spare parts Reason for return
Designation Quantity Part No. Report on fault
Repair
Checking as customer
service
Goods taken back
against credit note
To be completed by manufacturer
Report
by manufacturer only
To be completed
WP65L_BA1_en_1104.fm
92
S a u e r
C o m p r e s s o r
Type: WP 65 L
Spare parts catalogue
WP65L_ET1_Titel_en_1104.fm
WP65L_ET1_Titel_en_1104.fm
Page
Ref. No. Assembly Rev.
E-
065 865 Compressor unit WP 65 L.................................................... 6 5796-a
064 062 Cylinder with head and valve 1st stage ............................... 26 6384-b
064 063 Cylinder with head and valve 2nd stage .............................. 28 5682-b
E-3
Page
Ref. No. Assembly Rev.
E-
060 445 Oil level monitoring device (optional) ................................. 56 6047-i
Note:
Explanation of the assemblies in Chapter 3 "Design and
Function" in this Operator Manual.
WP65L_ET1_en_1104.fm
E-4
WP65L_ET1_en_1104.fm
Spare parts catalogue
E-5
065 865 Compressor unit WP 65 L
1 16
17 18 9, 14, 15
WP65L_ET1_en_1104.fm
E-6
Spare parts catalogue
1)
The order number for the electric motor depends on the individual order.
WP65L_ET1_en_1104.fm
E-7
065 867 Compressor WP 65 L
9 10 16
2 1, 15 14
WP65L_ET1_en_1104.fm
E-8
Spare parts catalogue
12
11
7 8
5
6
4
3
WP65L_ET1_en_1104.fm
E-9
065 867 Compressor WP 65 L
WP65L_ET1_en_1104.fm
E - 10
Spare parts catalogue
E - 11
064 478 Crankcase
1 11
21
20
12, 16, 17
6, 7
14, 16 10, 13
15, 19
WP65L_ET1_en_1104.fm
E - 12
Spare parts catalogue
1)
Item 10, tighten with tightening torque for 2nd stage from Chapter 8.4.
2) Item 13 and 14 inserted with Loctite 542.
3) Item 16, tighten with tightening torque for 1st stage from Chapter 8.4.
WP65L_ET1_en_1104.fm
E - 13
064 064 Dipstick
WP65L_ET1_en_1104.fm
E - 14
Spare parts catalogue
E - 15
064 058 Crankshaft
7 1 17 16
11
Y 15
3
Z 10
Y
18 5
12 15
4
14
WP65L_ET1_en_1104.fm
13
E - 16
Spare parts catalogue
1)
Item 18, 004 472 Dowel pin is part of assembly 064 642.
WP65L_ET1_en_1104.fm
E - 17
064 059 Connecting rod 1st stage
7 6
1
WP65L_ET1_en_1104.fm
E - 18
Spare parts catalogue
1)
Item 7, 031 883 Gudgeon pin is part of assembly 031 881.
WP65L_ET1_en_1104.fm
E - 19
064 060 Connecting rod 2nd stage
7 6
WP65L_ET1_en_1104.fm
E - 20
Spare parts catalogue
1)
Item 7, 064 074 Gudgeon pin is part of assembly 064 061.
WP65L_ET1_en_1104.fm
E - 21
031 881 Piston 1st stage
3
4
5 1
2
6
WP65L_ET1_en_1104.fm
E - 22
Spare parts catalogue
1)
Item 7, 036 107 Small-end bearing is part of assembly 064 059.
WP65L_ET1_en_1104.fm
E - 23
064 061 Piston 2nd stage
6
2
7
WP65L_ET1_en_1104.fm
E - 24
Spare parts catalogue
1)
Item 7, 037 156 Small-end bearing is part of assembly 064 060.
WP65L_ET1_en_1104.fm
E - 25
064 062 Cylinder with head and valve 1st stage
7, 9
8
4
WP65L_ET1_en_1104.fm
E - 26
Spare parts catalogue
1)
Item 9, 039 548 Filter element is part of assembly 039 547.
WP65L_ET1_en_1104.fm
E - 27
064 063 Cylinder with head and valve 2nd stage
8 5 7
6
9
WP65L_ET1_en_1104.fm
E - 28
Spare parts catalogue
E - 29
065 910 Cooler, complete
1 5 14 7 11, 15 10, 17 16
Z Y
4, 12, 15 9
12, 15
9
12, 15
8
8
13
4
6
WP65L_ET1_en_1104.fm
E - 30
Spare parts catalogue
1)
Insert with Loctite 542.
WP65L_ET1_en_1104.fm
E - 31
065 905 Cooler 1st stage
A-A 3 1
B
B-B
2
WP65L_ET1_en_1104.fm
E - 32
Spare parts catalogue
E - 33
064 068 Cooler 2nd stage
3 1 2 4
WP65L_ET1_en_1104.fm
E - 34
Spare parts catalogue
E - 35
064 072 Crankcase vent
2, 3, 8 12 11 9 11 4 5 6 1 7 10
WP65L_ET1_en_1104.fm
E - 36
Spare parts catalogue
1)
Insert with seal tape.
WP65L_ET1_en_1104.fm
E - 37
065 909 Air lines
10, 18 4
11, 19
12, 18
15, 17
10
1
14 13, 20 2 7
WP65L_ET1_en_1104.fm
E - 38
Spare parts catalogue
E - 39
063 121 Separator 2nd stage
11, 12 9
1
10
3
7
6
WP65L_ET1_en_1104.fm
E - 40
Spare parts catalogue
1)
121 °C / 250 °F
WP65L_ET1_en_1104.fm
E - 41
064 071 Compressor monitoring and control
1, 3 3, 6 4, 5 2
WP65L_ET1_en_1104.fm
E - 42
Spare parts catalogue
E - 43
062 407 Compressor monitoring and control 2nd stage
WP65L_ET1_en_1104.fm
E - 44
Spare parts catalogue
E - 45
060 354 Automatic drainage system
3 1 4 5
WP65L_ET1_en_1104.fm
E - 46
Spare parts catalogue
E - 47
064 070 Resilient mounts
9 10
6 5 7, 8 2 6 5 3, 4
WP65L_ET1_en_1104.fm
E - 48
Spare parts catalogue
E - 49
061 001 Hose line
1 2
WP65L_ET1_en_1104.fm
E - 50
Spare parts catalogue
E - 51
Flexible coupling
1 3 2
WP65L_ET1_en_1104.fm
E - 52
Spare parts catalogue
Flexible coupling
1) Item 1, 036 345 Compressor half coupling is part of assembly 065 866.
2) Item 2, 037 220 Motor half coupling is part of assembly 065 864.
3) Item 3, 033 494 Coupling flexible insert is part of assembly 065 864.
WP65L_ET1_en_1104.fm
E - 53
064 018 Temperature monitoring (option)
2, 4 1
WP65L_ET1_en_1104.fm
E - 54
Spare parts catalogue
E - 55
060 445 Oil level monitoring device (optional)
1
Z WP65L_ET1_en_1104.fm
E - 56
Spare parts catalogue
E - 57
E - 58
WP65L_ET1_en_1104.fm
Index
Page
Ref. No. Designation Assembly Item
E-
Solenoid valve ........................................ 060 354 46 1
Electric motor ......................................... 065 865 6 16
000 059 Hexagon head screw ............................. 064 058 16 11
000 066 Hexagon head screw ............................. 064 070 48 7
000 068 Hexagon head screw ............................. 064 070 48 3
000 119 Hexagon head screw ............................. 064 058 16 9
000 123 Hexagon head screw ............................. 065 910 30 13
000 147 Hexagon head screw ............................. 065 909 38 6
000 155 Hexagon head screw ............................. 065 865 6 10
000 184 Hexagon head screw ............................. 065 865 6 9
000 188 Hexagon head screw ............................. 064 058 16 10
000 269 Lifting eye bolt ........................................ 064 478 12 11
000 410 Cap screw .............................................. 064 018 54 2
000 493 Cap screw .............................................. 065 910 30 14
000 499 Cap screw .............................................. 065 865 6 18
000 499 Cap screw .............................................. 065 867 8 14
000 979 Plug ........................................................ 064 478 12 7
001 007 Plug ........................................................ 063 121 40 11
001 620 Hexagon nut ........................................... 064 478 12 10
001 620 Hexagon nut ........................................... 065 865 6 11
001 636 Washer ................................................... 065 865 6 12
001 637 Washer ................................................... 064 070 48 4
001 667 Lock plate ............................................... 064 058 16 12
001 886 Shaft seal ............................................... 064 478 12 20
WP65L_ET1_Index_en_1104.fm
E - 59
Page
Ref. No. Designation Assembly Item
E-
002 144 Washer ................................................... 064 018 54 4
002 156 Washer ................................................... 064 478 12 17
002 161 Washer ................................................... 065 865 6 8
002 166 Washer ................................................... 064 070 48 8
002 266 Cylindrical roller bearing ......................... 064 058 16 16
002 439 Circlip ..................................................... 064 058 16 13
002 548 Nose ring ................................................ 064 061 24 4
002 976 Circlip ..................................................... 031 881 22 6
002 980 Circlip ..................................................... 064 061 24 6
003 114 Lock washer ........................................... 065 910 30 15
003 496 Washer ................................................... 063 121 40 12
003 500 Washer ................................................... 064 071 42 5
004 408 Locking pin ............................................. 065 867 8 15
004 458 Dowel pin ................................................ 064 058 16 14
004 472 Dowel pin ................................................ 064 058 16 18
004 635 Fitting ..................................................... 060 354 46 5
004 641 Fitting ..................................................... 064 068 34 2
004 652 Fitting ..................................................... 065 905 32 2
004 694 Fitting ..................................................... 061 001 50 2
004 998 Fitting ..................................................... 064 068 34 3
005 009 Washer ................................................... 063 121 40 8
005 009 Washer ................................................... 064 068 34 4
005 009 Washer ................................................... 064 072 36 8
005 009 Washer ................................................... 064 478 12 19
005 009 Washer ................................................... 065 909 38 17
005 016 Washer ................................................... 064 063 28 8
WP65L_ET1_Index_en_1104.fm
E - 60
Index
Page
Ref. No. Designation Assembly Item
E-
005 029 Washer ................................................... 064 478 12 6
005 247 Hexagon head screw ............................. 065 910 30 11
005 671 Cap screw .............................................. 065 909 38 7
005 930 Stud screw ............................................. 064 478 12 12
006 186 Fitting ..................................................... 065 909 38 9
006 186 Fitting ..................................................... 065 910 30 16
006 187 Fitting ..................................................... 065 909 38 8
006 190 Fitting ..................................................... 065 905 32 3
006 205 Fitting ..................................................... 064 072 36 3
006 217 Fitting ..................................................... 065 909 38 13
006 225 Fitting ..................................................... 065 909 38 10
006 380 Reducing union ...................................... 064 072 36 2
006 381 Reducing union ...................................... 060 354 46 4
006 385 Reducing union ...................................... 064 063 28 5
006 385 Reducing union ...................................... 065 909 38 12
006 386 Reducing union ...................................... 065 909 38 11
006 390 Reducing union ...................................... 063 121 40 6
006 455 Stub ........................................................ 060 354 46 3
012 512 Plain ring ................................................ 031 881 22 3
012 597 Lock washer ........................................... 065 865 6 13
012 766 Pipe ........................................................ 064 072 36 12
012 862 Cutting ring ............................................. 065 910 30 17
030 340 O-ring ..................................................... 065 909 38 20
030 752 Safety valve 2nd stage ........................... 065 909 38 15
030 831 Shaft seal ............................................... 064 478 12 21
E - 61
Page
Ref. No. Designation Assembly Item
E-
031 881 Piston 1st stage ...................................... 065 867 9 6
031 883 Gudgeon pin ........................................... 031 881 22 2
031 883 Gudgeon pin ........................................... 064 059 18 7
031 901 Nose ring ................................................ 031 881 22 4
031 902 Oil scraper ring ....................................... 031 881 22 5
033 087 Reducer .................................................. 064 072 36 5
033 488 Non-return valve ..................................... 064 070 48 10
033 494 Coupling flexible insert ........................... 52 3
033 494 Coupling flexible insert ........................... 065 865 6 15
033 502 Fan wheel ............................................... 064 058 16 7
033 532 Hexagon head screw .............................. 065 910 30 12
033 952 Insulation tube ........................................ 064 072 36 10
034 612 Low-pressure hose ................................. 064 072 36 9
035 061 Washer ................................................... 062 407 44 3
035 061 Washer ................................................... 064 071 42 3
035 468 High air temperature switch .................... 064 018 54 1
035 520 O-ring ..................................................... 064 064 14 3
035 824 Filling cover ............................................ 064 072 36 1
036 041 Hexagon head screw .............................. 063 121 40 10
036 107 Small-end bearing .................................. 031 881 22 7
036 107 Small-end bearing .................................. 064 059 18 6
036 171 O-ring ..................................................... 063 121 40 9
036 345 Compressor half coupling ....................... 52 1
036 345 Compressor half coupling ....................... 065 867 8 16
037 076 Dipstick ................................................... 064 064 14 1
037 137 Y-joint ..................................................... 064 072 36 6
WP65L_ET1_Index_en_1104.fm
037 152 Stud screw, cylinder head 2nd stage ....... 064 478 12 13
037 153 Stud screw, cylinder head 1st stage ....... 064 478 12 14
037 154 Cylindrical roller bearing ......................... 064 058 16 17
E - 62
Index
Page
Ref. No. Designation Assembly Item
E-
037 155 Small-end bearing .................................. 064 059 18 5
037 155 Small-end bearing .................................. 064 060 20 5
037 156 Small-end bearing .................................. 064 060 20 6
037 156 Small-end bearing .................................. 064 061 24 7
037 157 Valve ...................................................... 064 062 26 8
037 158 Lamellar valve ........................................ 064 063 28 6
037 160 Socket fitting .......................................... 064 071 42 4
037 172 Mounting plate ....................................... 064 070 48 6
037 220 Motor half coupling ................................. 52 2
037 220 Motor half coupling ................................. 065 865 6 14
037 221 Separator 1st stage ................................ 065 909 38 14
037 526 O-ring ..................................................... 064 063 28 9
037 746 High pressure hose ................................ 064 070 48 9
038 264 Pressure gauge angle piece .................. 064 071 42 6
038 282 Pressure gauge 2nd stage ...................... 062 407 44 1
038 309 High pressure hose ................................ 061 001 50 1
038 919 Oil drain cock ......................................... 064 478 12 15
038 920 Stub ........................................................ 064 072 36 4
039 547 Silencer filter .......................................... 064 062 26 7
039 548 filter element .......................................... 064 062 26 9
040 300 Single ear clamp .................................... 064 072 36 11
056 235 Washer ................................................... 064 062 26 5
056 887 Washer ................................................... 064 058 16 4
056 914 Fan cover ............................................... 065 910 30 3
060 342 Fusible plug ............................................ 063 121 40 4
WP65L_ET1_Index_en_1104.fm
E - 63
Page
Ref. No. Designation Assembly Item
E-
064 062 Cylinder with head and valve 1st stage .. 065 867 9 7
064 063 Cylinder with head and valve 2nd stage . 065 867 9 8
064 064 Dipstick ................................................... 064 478 12 8
WP65L_ET1_Index_en_1104.fm
E - 64
Index
Page
Ref. No. Designation Assembly Item
E-
064 074 Gudgeon pin .......................................... 064 060 20 7
064 074 Gudgeon pin .......................................... 064 061 24 2
064 075 Clamp ..................................................... 065 910 30 9
064 122 Bearing housing ..................................... 064 478 12 2
064 124 Crankshaft .............................................. 064 058 16 1
064 126 Connecting rod ....................................... 064 059 18 2
064 128 Connecting rod ....................................... 064 060 20 2
064 129 Piston ..................................................... 064 061 24 1
064 130 Cylinder .................................................. 064 062 26 1
064 132 Cylinder .................................................. 064 063 28 1
064 134 Cylinder head ......................................... 064 062 26 2
064 135 Cylinder head ......................................... 064 063 28 2
064 137 Flange .................................................... 065 865 6 17
064 139 Flange .................................................... 065 910 30 5
064 268 Crankcase............................................... 064 478 12 1
064 341 Pipe ........................................................ 065 910 30 4
064 382 Flywheel ................................................. 064 058 16 2
064 478 Crankcase............................................... 065 867 8 1
064 522 Pipe nipple joint ...................................... 064 072 36 7
064 567 Clamp ..................................................... 065 909 38 2
064 642 Thrust washer ........................................ 064 058 16 5
064 643 Pipe ........................................................ 065 910 30 10
065 867 Compressor WP 65 L ............................. 065 865 6 1
065 904 Cooler .................................................... 065 905 32 1
065 905 Cooler 1st stage ..................................... 065 910 30 1
065 909 Air lines .................................................. 065 867 9 11
WP65L_ET1_Index_en_1104.fm
E - 65
Page
Ref. No. Designation Assembly Item
E-
066 708 Liner ....................................................... 064 058 16 6
066 719 Lubricating pin ........................................ 064 059 18 1
090 650 Piston ..................................................... 031 881 22 1
WP65L_ET1_Index_en_1104.fm