B 31.3
B 31.3
3 Points To Recall
A S S E T I N T E G R I T Y C O N S U L A T A N T C O M P A N Y
ASME B31.3
1. API 570 Code is applicable for inspection, repairs, alteration
and re-rating of in-service , metallic piping.
4. Table A-1B of B 31.3 Code gives weld joint quality factor for
manufactured pipes. The factor can be increased for Electric
Fusion welded pipes by conducting additional radiography
(spot or full) as per Table 302.3.4.
PD
tm C
2( SE PY )
_________________________________________________________________________________________________
Eng: MOHAMED AMER
E-mail:[email protected]
Mob. 010 149 77 330
Page 1 of 3
ASME B31.3 Points To Recall
A S S E T I N T E G R I T Y C O N S U L A T A N T C O M P A N Y
3P
t m dg C
16 SE
_________________________________________________________________________________________________
Eng: MOHAMED AMER
E-mail:[email protected]
Mob. 010 149 77 330
Page 2 of 3
ASME B31.3 Points To Recall
A S S E T I N T E G R I T Y C O N S U L A T A N T C O M P A N Y
18. Working pressure for flanges and flanged fittings can be read
from pressure-temperature ratings of flange. The hydrostatic
test pressure is taken as 1.5 times the pressure rating at
100º F, rounded to the next 25 psi.
_________________________________________________________________________________________________
Eng: MOHAMED AMER
E-mail:[email protected]
Mob. 010 149 77 330
Page 3 of 3