K 4541/5
Type HED 4OH1X/ ...K10S MIL01 (shown without protective cap)
Characteristics (For operation outside these parameters, please consult us!)
Fluids: HLP Mineral oil to DIN 51 524, Part 2 Salt spray: to MIL-STD-810 D
MIL-H-5606 (H 515) Method 509.2, Section II, Procedure I
MIL-H-6083 (C 635) – Cabinet temperature +35° C
MIL-H-13919 (H 540) – Concentration of salt solution 5 % NaCl
MIL-H-17672 (H 573) – Exposure duration 48 hours
DEF-STAN 91-31(H 576 or OM 33)
Viscosity range: 5 to 1000 mm2/s Vibration: to MIL-STD-810 D
2.8 to 2500 mm2/s with certain Method 514.3, Category 5 (Random Noise)
performance restrictions 15 to 89 Hz 0.04 g2/Hz
Temperature range: 89 to 300 Hz + 4 dB/Oct.
– Ambient temperature: –33° C to +70° C 300 to 1000 Hz 0.2 g2/Hz
– Fluid temperature: –33° C to +80° C 1000 to 2000 Hz – 6 dB/Oct.
– Storage temperature: –40° C to +80° C Shock: to Federal German Naval Construction
High temperatures: to MIL-STD-810 D Standard [BV 043]
Method 501.2, Procedure II Class I, External Structural Member
Category: 1 brief half sine shock 400g, 2 ms,
Hot / Induced Condition (+ 70° C) on each axis in each direction
Low temperatures: to MIL-STD-810 D 1 sustained half sine shock pulse 130g, 6 ms,
Method 502.2, Procedure II on each axis in each direction
Climatic region:
Basic Cold (– 35 °C)
Ordering code
Further details
HED 4 1X K10 S MIL01 * in clear text
no code. = NBR seals, suitable
without drain port
fluids see above
for subplate mounting = OP
for line mounting = OA V= FPM (Viton) seals, suitable
as vertical stacking element 1) = OH for phosphate ester (HFD-R)
with drain port S= protective cap
for line mounting = KA K10 = plug in connector A 10 SL 3 PN VG 95234 2)
Series 10 to 19 = 1X 50 = max. pressure setting 50 bar OP
(10 to 19, installation and connection 100 = max. pressure setting 100 bar HED 4OA
dimensions remain unchanged) 350 = max. pressure setting 350 bar OH
1 630 = max. pressure setting 630 bar OP
) Sandwich plate for vertical stacking to be ordered separately HED 4OA
2 630 = max. pressure setting 630 bar
) plug – separate order
100 = max. pressure setting 100 bar
350 = max. pressure setting 350 bar HED 4 KA
630 = max. pressure setting 630 bar