Technical Specs For Rotavapour

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

SPECIFICATIONS FOR ROTARY EVAPORATOR WITH VACUUM PUMP & CHILLER

ROTAVAPOR

 Electric/Motorized lift
 Provisions for automatic lifting of the flask in case of power failure
 Rotation clockwise and counter-clockwise with speed up to 280 rpm or better with microprocessor
control.
 The angle of the distillation flask from the horizontal to the bath is set at approximately 15°.
 Vertical Glass Assembly with cooling surface area of 1500 cm 2 with top hole on top of condenser
that allows easy cleaning. Should be P+G coated.
 Digital bath temperature display of both set and actual temperature simultaneously with
microprocessor control ranging from ambient to 220 deg C with an accuracy of ± 1 deg C.
 Bath temperature lock to prevents accidental change of settings
 Lift height indication should be digitally indicated on heating bath with 2 Lift Speeds.
 Push Button Interface for Single Centralized control of chiller, water bath, vacuum pump
 Safety Stop - Operation stop by Power Failure.
 Wireless contacts on the heating bath both for power supply and communication for better safety.
 Evaporating flask from 50-5000 ml can be used on the same joint adapter without additional
connections.
 LCD-display of Heating bath that displays all operating parameters Indicates set and actual
values of heating bath temperature, rotation speed and lift position
 Approvals CE / CSA
 Additional 2000 ml Evaporating flask other than two number 1000 ml capacity flask.
 Provision for Nitrogen supply into the rotary evaporator for specific application during sample
processing.
 Gas flow meter (100 to 1000 ml/min) for controlling the Nitrogen or CO2 purging into the
rotavapor system.

VACUUM CONTROLLER

 Vacuum controller with control knob and large graphic LCD display screen.
 Integrated solvent database of 43 solvents for convenient setting of distillation conditions.
 Centralized control of Speed control vacuum pump, Recircualting Chiller, Heating bath.
 Timer function for process termination after pre-specified time
 Set and actual cooling temperature display, as well as working pressure display on vacuum
controller.
 Woulff bottle included
 Single button operation to shut down Rotavapor, pump and re-circulating chiller at the end of
distillation.
 Approvals CE / CSA

Vacuum Pump

 Single stroke Speed control vacuum pump with a vacuum capacity of 1.8 m 3 /h.
 Final vacuum of 5mbar
 2 stage chemically resistant PTFE diaphragm pump
 Inspection window - A large glass window at front side should be there to observe the two pump
heads and membranes for eventual cleaning of the dirt particles.
 Approvals CE / CSA
Re-circulating Chiller

 Compact and Robust Re-circulating Chiller with a cooling capacity of 550 Watts at 15 deg C and
250 Watts at 0 deg C
 Temperature Range: -10 to 25 deg C
 Power consumption (max.) 800 W
 Temperature display resolution 0.1 °C
 Should have Temp Lock
 Coolant: CFC Free

NOTE: All accessories and spare parts including Vacuum pump, Chiller and Vacuum Controller
should be from the same Make/Manufacturer.

Warranty: One year from the date of installation.