Remote
- Possible to connect directly with DC2W or mechanical
limit switch 1
- DC2W and mechanical limit switches can be connected
in various combinations.
2 Sensor
- Standard switches can be used. 4
8
15 Products
Products table
table
DC3 wire
DC2 wire
DC2 wire/
Exclusive switch
DC2 wire/
Two air gaps
Sensor type Signal Operating Housing Exclusive proximity
page
(detector) Transmission distance max size Transmitter Output sensor switch
DC2 wire 2mm M12 RPT-1202D-PU RPE-1202 □ -PU 26 Terminal Box
-Standard proximity switch
1 4mm M18 RPT-1804D-PU RPE-1804 □ -PU 26
-Exdusive Proximity Swithch/
8mm M30 RPT-3008D-PU RPE-3008 □ -PU 27 Accessories
RFD Series
4mm M18 RPT2-1804D-PU RPE2-1804 □ -PU 28 Thermocouple
2 K
5mm M30 RPT2-3005D-PU RPE2-3005 □ -PU 28
Thermocouple
3mm M18 RPT4-1803D-PU RPE4-1803 □ -PU 30
4 J
5mm M30 RPT4-3005D-PU RPE4-3005 □ -PU 30 Resistance
3mm M18 RPT8-1803D-PU RPE8-1800 □ -PU 32 thermometer sensor
8
7mm M30 RPT8-3007D-PU RPE8-3000 □ -PU 32 Load Cell
15 5mm M30 RPT15-3005D-PU RPE15-3000 □ -PU 34
Analog sensor
Operating Applicable
Series Size Type name Page
distance Dimensions
Remote sensor
RFD sries for DC2 wire detector switch type 1.5mm M8 RFD-0801-PU RPT-xxxxD 40
(with LED) RPTx-xxxxD Installation
2mm M12 RFD-1202-PU 40
DC2W 5mm M18 RFD-1805-PU 40 Wiring
(RFD) 10mm M30 RFD-3010-PU 40
15
Remote Sensor System
Specification
Driving voltage
Applicable detector sensor:
Driving current
DC2 wire switch x 1
or Mechanicla switch x 1
1
Operating distance
cable length 3m = 03
5m = 05
26
1
Driving voltage
Driving current
1
Remote
Sensor
Operating distance
Dimensions
Installation
Typical Transmitting Diagram (supply voltage at 24V / non-flush mount )
RPT-1202D-PU-01 RPT-1804D-PU-01 RPT-3008D-PU-01 in:mm Wiring
□ -PU-02
RPT1202/RPE1202
RPE-1202 RPT-1804□/RPE-1804□
RPE-1804 □ -PU-02 RPT-3008□/RPE-3008□
RPE-3008 □ -PU-02
Y
XY
7 14
4 6 12
3 5 10 X
4 8 X:Center off-set
2 3 6 Y:Operating distance
1
2 4
1 2
8 6 4 2 0 2 4 6 8 10 8 6 4 2 0 2 4 6 8 10 201612 8 4 0 4 8 1216 20
Rated operating
distance
YXYX
27
Remote Sensor System
Specification
Driving voltage
Applicable detector sensor :
Driving current
DC2 wire switch or
Mechanical switch x max.2
max.2
1
Operating distance
RPT2-1804D-PU 03
cable length 3m = 03
5m = 05
28
2
Remote
Sensor
Products table
DC3 wire
DC2 wire
DC2 wire/
Exclusive switch
DC2 wire/
Two air gaps
Exclusive proximity
switch
Terminal Box
Accessories
Thermocouple
K
Thermocouple
J
Resistance
thermometer sensor
Load Cell
Analog sensor
Dimensions
Installation
Typical Transmitting Diagram (supply voltage at 24V / non-flush mount )
RPT2-1804D-PU-01 RPT2-3005D-PU-01 in:mm Wiring
RPE2-1804 □ -PU-02
RPT2-1804/RPE2-1804□ RPT4-3005D/RPE4-TF3005□
RPE2-3005 □ -PU-02
Y
5
8
4 X
6
3 X:Center off-set
2 4 Y:Operating distance
1 2
8 6 4 2 0 2 4 6 8 16 12 8 4 0 4 8 12 16
29
Remote Sensor System
Specification
Driving voltage
Applicable detector sensor:
Driving current
DC2 wire switch
or Mechanical switch x max.4
max.4
Operating distance
RPT 4-1803D-PU 03
cable length 3m = 03
5m = 05
30
4
Remote
Sensor
Products table
DC3 wire
DC2 wire
DC2 wire/
Exclusive switch
DC2 wire/
Two air gaps
Exclusive proximity
switch
Terminal Box
Accessories
Thermocouple
K
Thermocouple
J
Resistance
thermometer sensor
Load Cell
Analog sensor
Dimensions
Installation
Typical Transmitting Diagram (supply voltage at 24V / non-flush mount )
RPT4-1803D-PU-01 RPT4-3005D-PU-01 in:mm Wiring
RPT4-TF1803D/RPE4-TF1803□
RPE4-1803 □ -PU-02 RPT4-3005D/RPE4-TF3005□
RPE4-3005 □ -PU-02
Y
Y
5 8
4 X
6
3 X:Center off-set
4 Y:Operating distance
2
1 2
8 6 4 2 0 2 4 6 8 16 12 8 4 0 4 8 12 16
31
Remote Sensor System
Specification
Driving voltage
Applicable detector sensor
Driving current
DC2 wire switch
or Mechanical switch x max.8
max.8
Operating distance
RPT8-1803D-PU 03
cable length 3m = 03
5m = 05
32
8
Remote
Sensor
Products table
DC3 wire
DC2 wire
DC2 wire/
Exclusive switch
DC2 wire/
Two air gaps
Exclusive proximity
switch
Terminal Box
Accessories
Thermocouple
K
Thermocouple
J
Resistance
thermometer sensor
Load Cell
Analog sensor
Dimensions
Installation
Typical Transmitting Diagram (supply voltage at 24V / non-flush mount )
RPT8-1803D-PU-01 RPT8-3007D-PU-01 in:mm Wiring
RPE8-1800 □ -PU-02
RPT4-TF1803D/RPE4-TF1803□ RPE8-3000 □ -PU-02
8 Y
Y
7
5 6
4 5 X
3 4 X:Center off-set
3 Y:Operating distance
2
2
1 1
8 6 4 2 0 2 4 6 8 8 6 4 2 0 2 4 6 8
33
Remote Sensor System
Specification
Driving voltage
Applicable detector sensor :
Driving current
DC2 wire switch
or Mechanical switch x max.15
max.15
Operating distance
RPT15-3005D-PU 03
cable length 3m = 03
5m = 05
34
15
Remote
Sensor
Products table
DC3 wire
DC2 wire
DC2 wire/
Exclusive switch
DC2 wire/
Two air gaps
Exclusive proximity
switch
Terminal Box
Accessories
Thermocouple
K
Thermocouple
J
Resistance
thermometer sensor
Load Cell
Analog sensor
Dimensions
Installation
Typical Transmitting Diagram (supply voltage at 24V / non-flush mount )
RPT15-3005D-PU-01 in:mm Wiring
RPE15-3000 □ -PU-02
8 Y
7
6
5 X
4 X:Center off-set
3 Y:Operating distance
2
1
8 6 4 2 0 2 4 6 8
35