EMERGENCY TRANSPORT VENTILATOR

• COMBINES ADVANCED
TECHNOLOGY AND VERSATILE
VENTILATION FUNCTION

• MEETS THE BREATHING


REQUIREMENTS OF ADULTS,
PEDIATRICS AND INFANT PATIENTS

• PNEUMATICALLY DRIVEN
ELECTRONICALLY CONTROLLED
MULTI-FUNCTIONAL EMERGENCY
TRANSPORT VENTILATOR
It helps optimize quality of care & patient comfort, improving patient outcomes. One device adresses diverse
ventilation requirements, fully covering various situations.

Integrated with Versatile Ventilation Modes


• Pressure control & volume control mode
• Invasive & Non-Invasive ventilation
• SPONT/PSV, CPAP modes

Manual Respiratory Maneuver: Manual breath, Inspiratory hold

Enhancements:
• FiO² 40% to 100% continuously adjustable
• Waveform display: Pressure-time, Flow-time
• Alarm silence, Initial start-up test

Features:
• Simple operation, compact design and reliable performance
• Waveform display and ventilation parameter monitoring
• Electronically controlled PEEP
• Acoustic and visual alarms, anti-crash design
• Direct access to critical settings and patient data

Physical Specifications Measured values displayed


Dimensions (W x H x D) 175 mm x 170 mm x 300 mm Airway pressure measurement Peak inspiratory pressure (PIP)
-(6.89 inch x 6.69 inch x 11.81 Flow measurement Mandatory minute volume
inch) (MVmand)
Weight Approx. 3.2 kg (7.3 lbs) Tidal volume measurement Range: 0-3000ml
Mounting: Frequency measurement Range: 0-120 bpm
Equipped with frame Respiratory rate (RR)
and oxygen tank Approx. 9kg (19.8 lbs) Oxygen concentration Range: 21-100 %
Screen size 5“ LCD screen
Battery run time more than 4.5 hours Display calculated values
Work temperature -18 - 50°C Curve displays Airway pressure (t) (Paw)
-20 to 80 mbar (or hPa or cmH2O)
Patient type Flow-time
Adult 
Pediatric  Alarms / Monitoring
Airway pressure (Paw) High / Low
Infant 
Apnea alarm time (Tapn) 15 seconds
Battery low 
Ventilation modes External power lost 
A/C-V  O2 deficiency 
A/C-P  System breakdown 
SIMV-V  Oxygen concentration High / Low
SIMV-P  MV High / Low
SPONT/PSV  (All alarms with visual and audio signals)
CPAP 
SIGN  Performance data
Manual  Control principle Time-cycled, pressure-controlled,
continuous flow
Ventilation Settings Inspiratory flow 0 to 90 L/min
Ventilation frequency (RR) Apnea ventilation
1 to 120 bpm
1 to 40 bpm (SIMV)
Clinical prevention tool
Inspiratory hold
I:E Ratio 4:1 to 1:10
Inspiratory Time 0,1 – 15 s
Tidal Volume (VT) 0-2000ml Operating Data
Inspiratory Flow 0,1 – 90 L/min Main supply 100 V to 240 V, 50/60Hz,
PEEP 0 to 30mbar (or hPa or cmH2O) Main power connection Power: current ≤ 1.5A
TP 0 to 5s
PSV 0 to 50 cmH2O
PCV 5 to 50 cmH2O
CPAP 0 to 30 cmH2O
O2 concentration (FiO2) 40 to 100 Vol%
Trigger sensitivity Flow / Pressure
Flow 2-30 L/min
Pressure -20 to 0 mbar (or hPa or cmH2O) Subject to changes without prior notice!
HEYER Medical AG

Carl-Heyer-Str. 1/3
56130 Bad Ems
Germany
Tel. +49 2603 7913
Fax +49 2603 70424
[email protected]
www.heyermedical.de