Hyperplas Standard Membrane - TDS PDF
Hyperplas Standard Membrane - TDS PDF
MEMBRANE R
1
HYPERPLAS STANDARD
R
MEMBRANE
Uses completely to eliminate all sharp projections. After
Standard Membrane is used as a damp proofing cleaning, suitable primer such IWL Primer / IWL CS /
membrane in horizontal and vertical applications for IWL Blown Bitumen 85/25 or 90/15 is coated on the
protection of various substrates like concrete, masonry, surface (for more details refer relevant data sheets).
basement, roof slab in wide ranges of uses. Hyperplas Standard is unrolled over the coated surface
(with overlaps of 10cm) and bonded completely to the
Medium to large roof slab (domestic, commercial
substrate. The overlaps are then sealed by flame.
and industrial)
Special care is taken at singularities such as drains,
Basement and raft slabs.
expansion joints, etc. Details of application are
Roof Gardens where resistance is not required.
available in Hyperplas Application Guide.
Advantages Hyperplas Standard can be topped with topping such
as cement screed or tiles on accessible roofs with a
High tensile strength, tear and puncture resistance. chicken wire mesh reinforcement. Inaccessible roofs
Capable of withstanding thermal movements. can be topped with a layer of Bitumen followed with a
No flame hazard and environment friendly layer of IWL Aluminium Paint.
Fast application
Good adhesion to primed concrete substrates
Limitation
Application temperature ranges from 15⁰C to 50⁰C. It
Description is better to warm the back of the membrane for
Hyperplas Standard is a high softening point, APP application below 15⁰C and should be stored at above
modified polymeric waterproofing membrane 20⁰C before application to enable easy application and
manufactures to the highest technical standards. It immediate bond to the substrate.
consists of a center core of High Molecular High
Density Polyethylene film. This polyethylene film is the Packing
heart of the membrane and is a complete barrier Hyperplas Polyester Membrane: 10m length X 1m width
against water and moisture. The center core is Coldstick: 20 Kg container
protected on both sides with a high quality Polymeric
Asphaltic mix with properties of high penetration, high Coverage
heat resistance and high softening point to make it Coldstick: 3-4 per sq.m/kg on a standard smooth surface
ideal for waterproofing purposes. It also achieves high
bonding strength with substrate and a strong adhesion Storage
between overlaps. The Polymeric Asphaltic mix is All product have a shelf life of 12 months if stored in a
protected on both sides with thermofusible HMHDPE cool, dry place away from sources of heat, in the
film. This aids the thermofusion process and also original unopened packing. It should be stored
reinforces the non permeable quality of the entire horizontally, not more than one pallet high.
membrane. The resultant membrane has elongation
exceeding 300% to absorb all structural movements. It
also has high tensile strength and is extremely flexible
Safety measures
No health hazards with the use of Hyperplas
and pliable to adapt to contours.
Membrane and Coldstick. If Coldstick Primer is
swallowed, drink a glass of water and do not induce
Surface preparation vomiting. When contacted with eyes occurs flood with
Smooth surface is required to apply the membrane. copius amounts of clean water for at least 15 minutes
The surface is first cleaned to eliminate all sharp and seek medical advice. If contacted with skin wash
projection. the skin thoroughly.
Priming Fire
IWL Primer / IWL CS / IWL Blown Bitumen is then Hyperplas Membrane and Coldstick are flammable.
coated on the surface (for more details refer relevant Do not smoke near these products. Coldstick contains
data sheets). volatile flammable solvents. Use only in open areas,
well away from sources of ignition.
Application
Application of Hyperplas Standard is fast and easy. Specification
Smooth surface with minimum slope is required to Hyperplas Standard is available in grades of 2mm,
apply the membrane. The surface is first cleaned 3mm, 4mm, 2Kg, 3Kg, 3.5Kg or 4Kg.
2
HYPERPLAS STANDARD
R
MEMBRANE
Technical Support
Requirement
Requirement
Requirement for Mineral
for Method of
S. No. Test for Plain Membrane Unit
Aluminium Test, Ref to
Membrane (including
Membrane
Aluminium)
Weight thickness of
1 membrane(both plain 2 ± 5% 3 ± 5% 4 ± 5% Kg Measurement
and aluminum)
Tensile strength:
a)Plain: 70 ± 20% 120 ± 20% 130 ± 20% N/5cm
1)Longitudinal 60 ± 20% 100 ± 20% 100 ± 20% @23⁰C
IS 13826
4 2)Transverse (part 1)
b)3mm and above 100 ± 20% 120 ± 20% 150 ± 20% N/5cm
1)Longitudinal 80 ± 20% 100 ± 20% 100 ± 20% @23⁰C
2) Transverse
Elongation
a)Plain: 100 ± 20% 200 ± 20% 200 ± 20%
1) Longitudinal %
100 ± 20% 100 ± 20% 100 ± 20%
IS13826
5 2) Transverse
(Part 1)
b) Aluminum: 50 ± 20% 100 ± 20% 100 ± 20%
1) Longitudinal 50 ± 20% 100 ± 20% 100 ± 20%
2) Transverse
Penetration @ 25⁰C
100g,5s (both plain and Dmm (tenths
8 15 ± 5 15 ± 5 15 ± 5 IS 1203
aluminum) of mm)
3
R
DELHI
MUMBAI
VISAKHAPATNAM
CHENNAI
- Factory
01-2018-A